HWS1800T Series 1800W 3ph Industrial Power Supplies Features u Limited Lifetime Warranty u 208VAC Three Phase Input u High Efficiency u SEMI F47 Compliant u Compact Size Key Market Segments & Applications Specifications Model Input Voltage Range Input Current (Typical) Inrush Current (200VAC) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Indicator Remote on/off Parallel operation DC Good Remote Adjust (PV) Operating Temperature Storage Temperature Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock (In package) Safety Agency Approvals Line Dip Conducted & Radiated EMI Immunity Weight (Typ) Size (WxHxD) Warranty A A V ms mA C C g in yrs HWS1800 208VAC, Three phase 170 - 265VAC (47 - 63Hz) 3.3V: 4.5A, 5V to 15V: 6A, 24 to 60V: 7A 40A Typically 0.94 <0.02%/C >105% of maximum / peak current rating See table on page 2. Cycle input to reset or use remote on/off function 3.3V to 15V: 20ms, 24 to 60V: 18ms at 200VAC <2.6mA at 240VAC 60Hz Yes Green LED = ON Yes Single wire connection Yes External voltage adjusts output voltage. See Instruction Manual -10C to +71C, see output derating curves, -20C start up -30 to +85C Operating: 10 - 90%RH, Non operating 10 - 95%RH Internal fan I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC (1), O/P to CNT 100VAC for 1 min >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA60950-1, EN60950-1, EN50178 Complies with SEMI F47 EN55011 / EN55022-A, FCC-A, VCCI-A IEC61000-4-2, -3, -4, -5, -6, -8 3800 4.98 x 3.23 x 11" Limited lifetime warranty (See Lambda's terms & conditions) Notes: (1) HWS1800T-60V: 651VAC 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 67 Disclaimer: us.tdk-lambda.com/lp/legal.htm HWS1800T Series Outline Drawing SEE NOTE D 8-M4 (BOTH SIDES) SEE NOTE C 821 (56.8) 2600.5 7.25 (23.3) 10 46 MAX BUS BAR SPACER 20 3 3 L3 L2 BARCODE L1 BUS BAR SPACER 7.0 A 11 L1 INPUT TERMINAL SEE NOTE E NAME PLATE 4-M4 HWS1800T - 24 MADE IN JAPAN OUTPUT TERMINAL SEE NOTE E INPUT : 3O 200-240VAC 50 / 60Hz OUTPUT : 24 V 75 A 75 A L2 11 AIR FLOW (BLACK) HWS1800T - 24 L3 OUTPUT : 24 V 11 FG (14.6) NAME PLATE 8-M4 (BOTH SIDES) 351 9 2-O L2 22 7.0 A 600.5 L3 20 INPUT : 3O 200-240VAC 50 / 60Hz OUTPUT : 24 V 75 A (+) FG SEE NOTE C HWS1800T - 24 BARCODE (-) 1 4-M4 201 L1 MADE IN JAPAN 11 SEE NOTE B 45.51 CN01,CN02 +S +V -S -V COM PC REF PV TOG CNT 12 TOG PF 2 SEE NOTE A 10 NAME PLATE (NONE SCALE) 80 MAX FG (-) 1120.5 251 (+) (73.6) 1 11 126.51 (33) 23.71 CN01,CN02 +S +V -S -V COM PC REF PV TOG CNT TOG PF (11.2) 2 12 (9.1) (RED) HWS1800T - 24 OUTPUT : 24 V 75 A 11 SEE NOTE A 10 2600.5 20 MAX 2801 4 MAX Output Ratings Model HWS1800T-3 HWS1800T-5 HWS1800T-6 HWS1800T-7 HWS1800T-12 HWS1800T-15 HWS1800T-24 HWS1800T-36 HWS1800T-48 HWS1800T-60 Voltage V 3.3 5 6 7.5 12 15 24 36 48 60 Adjust Range V 2.64 - 3.96 4-6 4.8 - 7.2 6-9 9.6 - 14.4 12 - 18 19.2 - 28.8 28.8 - 43.2 38.4 - 52.8 48 - 66 Max Curr. A 300 300 250 200 125 100 75 50 37.5 30 Peak Curr. A(2) 300 240 150 120 105 70 52.5 42 Max Power W 990 1500 1500 1500 1500 1500 1800 1800 1800 1800 Peak Power W2 1800 1800 1800 1800 2520 2520 2520 2520 Load Reg mV 60 60 60 60 72 90 144 216 288 360 Line Reg mV(3) 36 36 40 40 48 60 96 144 192 240 Ripple Noise mV 120 120 150 150 200 200 250 250 300 400 Overvoltage V 4.12 - 4.62 6.25 - 7.0 7.5 - 8.4 9.37 - 10.5 15 - 17.4 18.7 - 21.8 30 - 34.8 45 - 49.7 55.2 - 60 69 - 75 Efficiency (typ) % 75 81 82 84 84 84 88 88 90 90 Notes (2) 10s maximum on time with 35% duty cycle (3) 180 - 265VAC Output Derating Curves Other Industrial Products HWS LZSA SWS DPP, DLP & DSP 15W to 1500W single output, single phase 500W to 1500W single output 50W to 1000W, low cost 10W to 960W DIN Rail mount For Additional Information, please visit us.tdk-lambda.com/lp/products/hws-series.htm 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 68 Revision A6: Mar 2012