SDM1100LP 1A SCHOTTKY BARRIER RECTIFIER VRRM (V) IO (A) 100 1 Features and Benefits VF(MAX) (V) @ +25C 0.77 IR(MAX) (A) @ +25C 0.35 UCT PROD INFORMATION ADVANCED PRODUCT NEWNEW ADVANCED INFORMATION Product Summary Guard Ring Die Construction Transient Protection Low Power Loss. High Efficiency Reduced ultra-low forward voltage drop (VF); Better efficiency and cooler operation. Reduced high temperature reverse leakage and increased reliability against thermal runaway failure in high temperature operation. Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. "Green" Device (Note 3) Qualified to AEC-Q101 Standards for High Reliability Description and Applications Mechanical Data The Schottky Barrier Rectifier is designed with low VF and low reverse leakage in the low profile U-DFN2020-2 (Type B) package. It is ideal for use as a rectifier, freewheel diode or blocking diode in applications such as: Case: U-DFN2020-2 (Type B) Case Material: Molded Plastic, "Green" Molding Compound; UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Finish - Matte Tin Annealed over Copper Leadframe; Solderable per MIL-STD-202, Method 208 Polarity: See Below Weight: 6.757mg (Approximate) Blocking Diode Boost Diode Recirculating Diode U-DFN2020-2 (Type B) Top View Internal Schematic Bottom View Top View Ordering Information (Note 4) Part Number SDM1100LP-7 Notes: Case U-DFN2020-2 (Type B) Packaging 3,000/Tape & Reel 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated's definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green" products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. For packaging details, go to our website at http://www.diodes.com/products/packages.html. Marking Information 1100 = Product Type Marking Code YM = Date Code Marking Y = Year (ex: D = 2016) M = Month (ex: 6 = June) Bar = Cathode Date Code Key Year Code Month Code 2014 B Jan 1 2015 C Feb 2 SDM1100LP Document number: DS38515 Rev. 2 - 2 2016 D Mar 3 Apr 4 2017 E May 5 2018 F Jun 6 1 of 5 www.diodes.com 2019 G Jul 7 Aug 8 2020 H Sep 9 2021 I Oct O 2022 J Nov N Dec D April 2016 (c) Diodes Incorporated SDM1100LP Maximum Ratings (@TA = +25C, unless otherwise specified.) Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristic Value Unit VRRM VRWM VRM 100 V Average Rectified Output Current IO 1 A IFSM 40 A UCT Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load Thermal Characteristics Symbol Value Unit Typical Thermal Resistance Junction to Case (Note 5) RJC 16 C/W Typical Thermal Resistance Junction to Ambient (Note 5) Characteristic RJA 65 C/W TJ -55 to +175 C TSTG -55 to +175 C Operating Temperature Range Storage Temperature Range Electrical Characteristics (@TA = +25C, unless otherwise specified.) Characteristic Reverse Breakdown Voltage Forward Voltage (Note 6) Leakage Current (Note 6) Total Capacitance VF IR CT Min 100 Typ -- Max -- Unit V Test Condition IR=1mA -- -- 0.77 -- 0.58 0.62 -- -- 0.86 -- 0.65 0.70 -- -- 0.1 A VR = 50V, TJ = +25C -- -- 0.015 mA VR = 50V, TJ = +85C -- -- 0.35 A VR = 100V, TJ = +25C -- -- 0.35 mA VR = 100V, TJ = +125C -- 40 -- pF VR = 5V, f = 1MHz IF = 1A, TJ = +25C V IF = 1A, TJ = +125C IF = 2A, TJ = +25C IF = 2A, TJ = +125C 5. Device mounted 1inch sq. copper pad, 2oz. 6. Short duration pulse test used to minimize self-heating effect. )A 10 ( T N E R R U 1 C D R A W R 0.1 O F S U O 0.01 E N A T N A T 0.001 S N I, F I 0.0001 Symbol V(BR)R IR , INSTANTANEOUS REVERSE CURRENT (A) Notes: IF, INSTANTANEOUS FORWARD CURRENT (A) PROD INFORMATION ADVANCED PRODUCT NEWNEW ADVANCED INFORMATION Symbol Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage T A = 175C T A = 150C T A = 125C TA = 85C TA = 25C T A = -55C 1000 TA = 175C T A = 150C 100 TA = 125C 10 T A = 85C 1 0.1 T A = 25C 0.01 T A = -55C 0.001 0 100 200 300 400 500 600 700 800 900 1000 VF , INSTANTANEOUS FORWARD VOLTAGE (mV) Figure 1 Typical Forward Characteristics SDM1100LP Document number: DS38515 Rev. 2 - 2 2 of 5 www.diodes.com 0 20 40 60 80 100 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Figure 2 Typical Reverse Characteristics April 2016 (c) Diodes Incorporated I F(AV), AVERAGE FORWARD CURRENT (A) UCT 1 0.8 Note 5 0.6 0.4 0.2 0 25 50 75 100 125 150 175 TA, AMBIENT TEMPERATURE (C) Figure 3 DC Forward Current Derating Curve 2.5 o C TJTj=175 =175 C 2 1.5 1 0.5 0 0 0.5 1 1.5 2 2.5 3 3.5 4 IF(AV) AVERAGE FORWARD CURRENT (A) Figure 4 Forward Power Dissipation 1000 f=1MHz CT, TOTAL CAPACITANCE (pF) PROD INFORMATION ADVANCED PRODUCT NEWNEW ADVANCED INFORMATION 1.2 P D, AVERAGE FORWARD POWER DISSIPATION (W) SDM1100LP 100 10 0 5 10 15 20 25 30 35 VR, DC REVERSE VOLTAGE (V) Figure 5 Total Capacitance vs. Reverse Voltage SDM1100LP Document number: DS38515 Rev. 2 - 2 40 3 of 5 www.diodes.com April 2016 (c) Diodes Incorporated SDM1100LP Package Outline Dimensions A A1 Seating Plane D Z1 D2 UCT PROD INFORMATION ADVANCED PRODUCT NEWNEW ADVANCED INFORMATION Please see http://www.diodes.com/package-outlines.html for the latest version. E2 E k L U-DFN2020-2 (Type B) Dim Min Max Typ A 0.47 0.53 0.50 A1 0.00 0.05 0.02 b 1.55 1.65 1.60 D 1.95 2.05 2.00 D2 1.50 1.70 1.60 E 1.95 2.05 2.00 E2 1.22 1.42 1.32 k 0.25 BSC L 0.23 0.33 0.28 Z 0.20 BSC Z1 0.075 BSC All Dimensions in mm b Z Suggested Pad Layout Please see http://www.diodes.com/package-outlines.html for the latest version. Y X Dimensions G G X X1 Y Y1 Y2 Y2 Y1 Value (in mm) 0.150 1.700 1.700 0.480 1.520 2.150 X1 SDM1100LP Document number: DS38515 Rev. 2 - 2 4 of 5 www.diodes.com April 2016 (c) Diodes Incorporated SDM1100LP IMPORTANT NOTICE Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. UCT PROD INFORMATION ADVANCED PRODUCT NEWNEW ADVANCED INFORMATION DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2016, Diodes Incorporated www.diodes.com SDM1100LP Document number: DS38515 Rev. 2 - 2 5 of 5 www.diodes.com April 2016 (c) Diodes Incorporated