Functionelement,MSC-DEA/XTSEA Deliveryprogramme Partno. Articleno. PKE-SWD-32 126895 Product range SmartWire-DT slave Basic function Motor protection Motor protection for heavy starting duty Product range Accessories Accessories SmartWire-DT PKE module (motor-starter combinations) Function For connecting the motor-starter combination to SmartWire-DT, "expanded" 24 VDC version (MSC-DEA...) up to 15 kW. Description Surface-mounting to contactors. One module per contactor and PKE necessary. Additional SWD contactor module required fir actuation of reversing starter. 1 electrical interlock for the surface mounting of reversing starters. 1-0-A switch for manual or automatic operation. Selectable overload relay function (ZMR) for switching off the contactor on overload. Wiring sets DILM 12-XRL and PKZM0-XRM12 cannot be used. Messages Switch position contactor/PKE/1-0-A switch Motor current in % Thermal motor image in % Trip indications (Overload, Short-circuit,...) Set value of overload releases Set time lag (CLASS) Part no. of trip block Commands Contactor actuation Activation Overload relay function (ZMR) Information about equipment supplied Connecting cable between module and trip block PKE-XTUA-... included as standard. For use with DILM(C)7... - DILM(C)32 MSC-DEA Connection to SmartWire-DT yes Connection type Push in terminals Notes * * * * Take into account the max. current consumption of the contactor coils per SmartWire-Darwin line. A2 connections must not be bridged. Wiring sets DILM 12-XRL and PKZM0-XRM12 cannot be used. Additional SWD contactor module required fir actuation of reversing starter. Approvals NA Certification Request filed for UL and CSA Partno. PKE-SWD-32 Standards IEC/EN 61131-2 EN 50178 IEC/EN 60947 General Dimensions (W x H x D) mm 45 x 38 x 76 Weight kg 0.04 Mounting on DILM7...DILM32 Mounting position as DILM7 to DILM32 Protection type (IEC/EN 60529, EN50178, VBG 4) IP20 Ambientconditions,mechanical Vibrations (IEC/EN 61131-2:2008) Constant amplitude 3,5 mm Hz 5 - 8.4 Constant acceleration 1 g Hz 8.4 - 150 Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms Drop to IEC/EN 60068-2-31 Free fall, packaged (IEC/EN 60068-2-32) Electromagneticcompatibility(EMC) Impacts 9 Drop height mm 50 m 0.3 Overvoltage category II Pollution degree 2 06/25/2012 HPL-ED2012 V1.1 EN 1/4 Electrostatic discharge (IEC/EN 61131-2:2008) Air discharge (Level 3) kV 8 Contact discharge (Level 2) kV 4 80 - 1000 MHz V/m 10 1.4 - 2 GHz V/m 3 2 - 2.7 GHz V/m 1 Electromagnetic fields (IEC/EN 61131-2:2008) Radio interference suppression (SmartWire-DT) EN 55011 Class A Burst (IEC/EN 61131-2:2008, Level 3) CAN/DP bus cable kV 1 SmartWire-DT cables kV 1 Radiated RFI (IEC/EN 61131-2:2008, Level 3) V 10 Operating ambient temperature (IEC 60068-2) C Climaticenvironmentalconditions Ambient temperature C -25 - +60 Condensation Take appropriate measures to prevent condensation Storage C -30 - +70 relative humidity, non-condensing (IEC/EN 60068-2-30) % 5 - 95 SmartWire-DTnetwork Station type SmartWire-DT slave Address allocation SmartWire-DT status LED automatic LED Connections Plug, 8-pole Connection Current consumption green/orange External device plug SWD4-8SF2-5 mA 58 for DILM 7-9 W 3 for DILM 12-15 W 4.5 for DILM 17-38 W 12 for DILM 7-9 mA 125 for DILM 12-15 mA 188 for DILM 17-38 mA 500 for DILM 7-9 W 3 for DILM 12-15 W 4.5 for DILM 17-38 W 0.5 for DILM 17-38 mA 21 for DILM 12-15 mA 188 for DILM 7-9 mA 125 Pick-up power Pick-up current Holding power Holding current Modeparameter Manual/automatic mode yes Setting Rotary switch Connectionauxiliarycontact Cable length m 2.8 Connection type Terminalcapacities Push in terminals Solid mm Flexible with ferrule mm TechnicaldataETIM4.0 2 0.2 - 1.5 (AWG 24 - 16) 2 0.25 - 1.5 Radiostandard Bluetooth No Short-circuit protective device, outputs available No Type of voltage (input voltage) DC 06/25/2012 HPL-ED2012 V1.1 EN 2/4 Flush mounting plates possible Height No mm 38 Performance level acc. to EN ISO 13849-1 A Number of HW-interfaces other 2 Number of outputs 1 Supporting protocol for PROFIsafe No Supply voltage DC V 15 Supply voltage AC 60 Hz V 0 Supporting protocol for EtherNet/IP No IO link master No Number of HW-interfaces USB 0 Supporting protocol for TCP/IP No With optical interface No Wall mounting/direct mounting No Number of HW-interfaces serial TTY 0 Appendant apparatus (Ex ib) No Supporting protocol for other bus systems YES Supporting protocol for DeviceNet Safety No Protection type (IP) IP20 Supporting protocol for PROFINET IO No Supporting protocol for Data-Highway No Voltage type of supply voltage DC Supporting protocol for CAN No Type of electric connection Spring clamp connection Category to EN 954-1 1 Number of inputs 0 Permitted voltage at input V Number of HW-interfaces RS232 15 0 Rack-mounting possible No Input current at signal 1 mA 0 Width mm 45 System component YES Explosion safety category for dust without Supporting protocol for INTERBUS-Safety No Supporting protocol for SUCONET No Supporting protocol for DeviceNet No Supporting protocol for SafetyBUS p No Fieldbus connection over separate bus terminal possible YES Depth mm 77.3 SIL according to IEC 62061 0 Supporting protocol for EIB No SIL according to IEC 61508 0 Output current A 0.5 Type of digital output - Radiostandard WLAN 802.11 No Associated apparatus (Ex ia) Delay time on signal change No ms 84 Number of HW-interfaces Wireless 0 Supporting protocol for MODBUS No Supporting protocol for SERCOS No Safety class according to DIN V 19250 0 Supporting protocol for Foundation Fieldbus No Supporting protocol for LON No Supporting protocol for INTERBUS No Type of output voltage DC 06/25/2012 HPL-ED2012 V1.1 EN 3/4 Supporting protocol for PROFIBUS No Number of Industrial Ethernet HW interfaces 0 Number of HW-interfaces PROFINET 0 Permitted voltage at output V 28.8 Supporting protocol for AS-Interface Safety at Work No Number of HW-interfaces RS485 0 Explosion protection for gas without Supporting protocol for AS-Interface No Supporting protocol for PROFINET CBA No Supply voltage AC 50 Hz V 0 Number of HW-interfaces parallel 0 Rail mounting possible No Number of HW-interfaces RS422 0 In-/outputs configurable No Suitable for safety functions No Dimensions SmartWire-DT PKE module (motor-starter combinations) Additionalproductinformation(links) IL03402024Z(AWA1210-2706)SmartWire-DT:FunctionelementforPKE12/32,MSC-DEA IL03402024Z (AWA1210-2706) SmartWire-DT: Function element for PKE12/32, MSC-DEA ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL03402024Z2010_08.pdf MN05006001Z-EN(AWB2723-1613)SmartWire-DT,Unit MN05006001Z-EN(AWB2723-1613) SmartWire-DT, Unit - Deutsch ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05006001Z_DE.pdf MN05006001Z-EN(AWB2723-1613) SmartWire-DT, Unit - English ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05006001Z_EN.pdf MN05006001Z-IT (AWB2723-1613) SmartWire-Darwin utenti - italiano ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN05006001Z_IT.pdf Motor starters and "Special Purpose Ratings" for the North American market http://www.moeller.net/binary/ver_techpapers/ver953en.pdf Busbar Component Adapters for modern Industrial control panels http://www.moeller.net/binary/ver_techpapers/ver960en.pdf 06/25/2012 Eaton Industries GmbH http://www.moeller.net/en (c) 05/2012 by Eaton Industries GmbH HPL-ED2012 V1.1 EN (UX111) 4/4