Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
ECONOLINE
DC/DC-Converter
with 3 year Warranty
RU/RUM
EN-60950-1 Certified
Part Input Output Output Output Efficiency Max
Number Voltage Voltage Voltage Current typ. Capacitive
SIP 7 2kV (VDC) (V1VDC) (V2VDC) (mA) (%) Load(1)
RU-3.30505 (H) 3.3 5 5 100/100 76 470µF/470µF
RU-050505 (H) 5 5 5 100/100 72 470µF/470µF
RUM-3.30505 (H) 3.3 5 5 100/100 78 470µF/470µF
RUM-050505 (H) 5 5 5 100/100 72 470µF/470µF
Other input and output voltage combinations available on request
* add Suffix “P” for Continuous Short Circuit Protection,
e.g. RU-050505/P, RUM-050505/P, RU-3.30505/HP
1 Watt
SIP7
Isolated
Dual Output
Derating-Graph
(Ambient Temperature)
●Twin Independent Outputs
●Output/Output Isolation 1kVDC
●Power Sharing on Outputs
●Input/Output Isolation 1kVDC
●Standard and Miniature Versions
●Optional Continuous Short Circuit Protected
●Custom Solutions Available
●Efficiency to 76%
Features
Unregulated
Converters
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 15% max
(10%~100% Load) 10% typ.
Output Ripple and Noise (20MHz limited) RU 75mVp-p max.
Full Load RUM 100mVp-p max.
Operating Frequency 20kHz min. / 70kHz typ. / 105kHz max.
Efficiency at Full Load RU 70% min.
RUM 70% min.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 1000VDC
Input/Output and Output/Output (rated for 1 minute**) 500VAC / 60Hz
Isolation Voltage H-suffix (tested for 1 second) 2000VDC
Input/Output H-suffix (rated for 1 minute**) 1000VAC / 60Hz
Output/Output H-suffix (rated for 1 minute**) 500VAC / 60Hz
Isolation Capacitance 20pF min. / 94pF max.
Isolation Resistance 10 GΩmin.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 2.7g
Packing Quantity RU 25 pcs per Tube
RUM 30 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1012 x 103 hours
(+85°C) using MIL-HDBK 217F 151 x 103 hours
Certifications
EN60950-1 Report: SPCLVD1109103 EN60950-1: 2006+A12:2011
Selection Guide
}
Detailed Information see
Application Notes chapter "MTBF"
The RU DC/DC converter offers two independent isolated outputs. Typical applications include
multiple channel circuits where inter-channel isolation is also required. The RUM offers
similar specifications in a miniature case for applications where space is at a premium. Both
converters offer 1KVDC input/output isolation and 1kVDC output/output isolation.
The /H versions offer 2kVDC isolation between input and outputs.
Description
Refer to Application Notes
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature and based
on our practical experience only. For further details, please refer to our
Application Notes.
REV: 0/2015 E-79www.recom-power.com