45 WATTS SRW-45 SERIES AC-DC OUTPUT SPECIFICATIONS FEATURES: RoHS Compliant Universal 85-264 VAC Input Compact 3" x 5" x 1.12" Size 2 year Warranty Fits 1U Applications One to Four Outputs EN 60950-1 ITE Certification Class B Emissions per EN 55022 Optional Chassis and Cover Total Output Power Output Voltage Centering Output Voltage Adjust Range Load Regulation Source Regulation Cross Regulation OPEN FRAME CHASSIS/COVER SAFETY SPECIFICATIONS Protection Class: Overvoltage Category: Pollution Degree: General Underwriters Laboratories File E137708/E140259 I II 2 UL 60950-1 2nd Edition, 2007 CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition EN 60950-1/A2:2013 TUV Low Voltage Directive RoHS Directive (Recast) (2014/35/EU of February 2014) (2011/65/EU of June 2011) 110% to 150% Outputs 1-4: 110% Min. Outputs cycle on/off, auto recovery 16 mS min., 45W Output, 120V Input 1 Second Source Voltage Frequency Range Source Current True RMS Peak Inrush Efficiency 85 - 264 Volts AC 47 - 63 Hz 1A at 85V Input 40 A .68-.72 (Varies by model) ENVIRONMENTAL SPECIFICATIONS Ambient Operating Temperature Range Ambient Storage Temp. Range Temperature Coefficient Conducted Emissions 0 C to + 50 C Derating: See Power Rating Chart - 40 C to + 85 C Outputs 1 - 4: 0.02%/C EN 55022 Class B GENERAL SPECIFICATIONS MODEL LISTING MODEL NO. OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 SRW-45-4001 SRW-45-4002 SRW-45-4003 SRW-45-4004 SRW-45-4005 SRW-45-4006 SRW-45-4007 SRW-45-4008 SRW-45-4009 SRW-45-4011 SRW-45-4012 SRW-45-3001 SRW-45-3002 SRW-45-3003 SRW-45-3004 SRW-45-3005 SRW-45-3006 SRW-45-2001 SRW-45-2002 SRW-45-2003 SRW-45-2004 SRW-45-2005 SRW-45-2006 SRW-45-2007 SRW-45-2008 SRW-45-2009 SRW-45-2010 SRW-45-1001 SRW-45-1002 SRW-45-1003 SRW-45-1004 SRW-45-1006 -5V/2A -5V/2A +24V/1A +24V/1A +24V/1A +15V/2A 8V/.50A +3.3V/3A +27V/1A +24V/1A +12V/3A +12V/3A +15V/2A +24V/1.5A +9V/3A 18V/2A +15V/2.5A +12V/3A -5V/4A +24V/1.5A -12V/2A -15V/2A 15V/3A -18V/1A +13V/3A +21V/1A -5V/4A +12V/.70A +15V/.70A +12V/.70A +15V/.70A -12V/.70A +15V/.70A 18V/.70A 5V/3A +15V/.70A +15V/.70A 9V/1A -12V/.70A -15V/.70A -12V/.70A -15V/.70A -5V/.70A -15V/.70A 18V/.70A 12V/.70A -15V/.70A -15V/.70A -12V/.70A -12V/.70A -15V/.70A -12V/.70A 12V/.70A 18V/.70A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A 8V/2A +3.3V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +5V/5A +12V/3A +15V/2.5A 5V/5A +18V/1.5A +5V/5A +5V/2.5A +5V/5A 5V/9A 12V/4A 15V/3A 24V/2A 13.8V/3.3A Hold Up Time Start Up Time 0.25% (All outputs 5.0% at 50% load) 3.0% 3.0% 95 - 105% 0.5% (20-100% load change) 5.0% (10-70% load change) 2.0% (10-100% load change) 2.0% (10-100% load change) 0.5% 5.0% (Output 1 load 2.0% varied 50-100%) 2.0% 1.0% INPUT SPECIFICATIONS CB Certificate per IEC 60950-1/A2:2013 including all National Deviations UL Recognition Mark for Canada File E137708/E140259 Output Noise Turn on Overshoot Transient Response Voltage Deviation Recovery Time Load Change Output Overvoltage Protection (optional) Output Overpower Protection 45W Output 1: Output 2: Output 3: Output 4: Output 1: Output 1: Output 2: Output 3: Output 4: Outputs 1 - 4: Output 2: Output 3: Output 4: Outputs 1 - 4: None Outputs 1 - 4 5.0% 2 mS 50% to 100% Output 1: -15V/2.5A Dielectric Strength(7) Reinforced Insulation Basic Insulation Operational Insulation Mean-Time Between Failures Weight 4242 VDC, Primary to Secondary, 1 Sec. 2121 VDC, Primary to Ground, 1 Sec. 500 VDC, Secondary to Ground, 1 Sec. 150,000 Hours min., MIL-HDBK-217F, 25 C, GB 0.50 Lbs. Open Frame 1.00 Lbs. Chassis and Cover NOTES Consult factory for alternate output configurations. Consult factory for positive, negative or floating output 2. Refer to Applications Information for complete output power ratings. All specifications are maximum at 25 C, 45W unless otherwise stated, may vary by model and are subject to change without notice. Centering, load regulation and cross regulation are rated at 5% on output 3 for models SRW-45-3006 and SRW-45-4008. TUV only: SRW-45-3006, SRW-45-4010 ORDERING INFORMATION Other output configurations available (consult factory) Please specify the following optional features when ordering: CH - Chassis CO - Cover OVP - Overvoltage protection TS - Terminal Strip I/O - Isolated outputs INTEGRATED POWER DESIGNS 300 Stewart Road Wilkes-Barre, PA 18706 Phone: (570) 824-4666 Fax: (570) 824-4843 Email: sales@ipdpower.com Web: www.ipdpower.com SRW-45 SERIES MECHANICAL SPECIFICATIONS APPLICATIONS INFORMATION 1. OPEN FRAME 1.53 (38.9) 1.75 (44.5) 6-32 MTG HOLE (2 PLACES) Each output can deliver its rated load but total output power must not exceed 45 watts. Semiconductor case temperatures must not exceed 110C. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air to develop. This product is intended for use as a professionally installed component within information technology. A minimum load of 20% is required on output one to insure proper regulation of remaining outputs. Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. This product was type tested and safety certified using the dielectric strength test voltages listed in Table 5B of UL 60950-1. In consideration of Clause 5.2.2, care must be taken to insure that the voltage applied to a reinforced insulation does not overstress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC equivalent test voltages be used when performing a production-line dielectric strength test of the assembled end product. Please consult factory for further information. This power supply has been safety approved and final tested using a DC dielectric test. Please consult factory before performing an AC dielectric strength test. Maximum screw penetration into mounting holes is .250 inches. 2. 3. 4. .50 (12.7) CAP 5. 6. GND .157 (3.9) DIA MTG HOLE (4 PLACES) 2 7. CAP TB2 3 3 AC INPUT N TB1 L TB2 8 (-) 7 (-) 6 (+) 5 (+) 4 (-) 3 (-) 2 (+) 1 (+) OUTPUT 1 OUTPUT 1 OUTPUT 1 OUTPUT 1 OUTPUT 2 OUTPUT 2 OUTPUT 2 OUTPUT 2 1 1 V1 ADJUST 1XXX, 2XXX OUTPUT MODELS 9. MAXIMUM OUTPUT POWER VS. AMBIENT TEMPERATURE 5.00 (127.0) .225 (5.7) TYP 8. 4.55 (115.6) .157 (3.9) DIA MTG HOLE (4 PLACES) GND 45 2.55 (64.8) 3.00 (76.2) TB2 AC INPUT N TB1 L TB2 8 (-) 7 (+) 6 (-) 5 (+) 4 (+) 3 (-) 2 (+) 1 (-) Output Power (Watts) 40 CAP OUTPUT 1 OUTPUT 1 OUTPUT 2 OUTPUT 2 OUTPUT 3 OUTPUT 3 OUTPUT 4 OUTPUT 4 1 V1 ADJUST 35 30 25 20 15 10 5 3XXX, 4XXX OUTPUT MODELS 0 0 CAP 10 20 30 40 50 60 70 Ambient Temperature (C) 1.10 (27.9) 1.25 (31.8) MAX CONNECTOR SPECIFICATIONS OPTIONAL CHASSIS/COVER .56 (14.2) TB1 AC Input TB2 DC Output G Ground 4.00 (101.6) 6-32 MTG HOLE (2 PLACES) .81 (20.6) .156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal. .156 friction lock header mates with Molex 09-50-3081 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal. .187 quick disconnect terminal. 1.56 (39.6) RECOMMENDED AIR FLOW DIRECTION 1 - Optimum 5.15 (130.8) .84 (21.3) .30 (7.6) 2 - Good 3 - Fair 3.50 (88.9) 2 TB2 2.50 (63.5) 3 3 3.25 (82.6) N TB1 L 1 1 ALL DIMENSIONS IN INCHES (MM) 6-32 MTG HOLE (4 PLACES - BASE) REV.F 05/27/2016 INTEGRATED POWER DESIGNS 300 Stewart Road Wilkes-Barre, PA 18706 Phone: (570) 824-4666 Fax: (570) 824-4843 Email: sales@ipdpower.com Web: www.ipdpower.com