LTC1535
4
1535fc
For more information www.linear.com/LTC1535
elecTrical characTerisTics
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
tSJ Data Sample Jitter Figure 8, (Note 7) l250 285 ns
fMAX Max Baud Rate Jitter = 10% Max, SLO = 1, (Note 8) l250 410 kBd
tPLH Driver Input to Output DE = 1, SLO = 1, Figure 4, Figure 6
DE = 1, SLO = 0, Figure 4, Figure 6
l
l
600
1300
855
1560
ns
ns
tPHL Driver Input to Output DE = 1, SLO = 1, Figure 4, Figure 6
DE = 1, SLO = 1, Figure 4, Figure 6
l
l
600
1300
855
1560
ns
ns
tr, tfDriver Rise or Fall Time DE = 1, SLO = 1, Figure 4, Figure 6
DE = 1, SLO = 0, VCC = VCC2 = 4.5V
l
l
150
20
500
100
1000
ns
ns
tZH Driver Enable to Output DI = 1, SLO = 1, Figure 5, Figure 7 l1000 1400 ns
tZL Driver Enable to Output DI = 0, SLO = 1, Figure 5, Figure 7 l1000 1400 ns
tLZ Driver Disable to Output DI = 0, SLO = 1, Figure 5, Figure 7 l700 1300 ns
tHZ Driver Disable to Output DI = 1, SLO = 1, Figure 5, Figure 7 l700 1300 ns
tPLH Receiver Input to RO RE = 0, Figure 3, Figure 8 l600 855 ns
tPHL Receiver Input to RO RE = 0, Figure 3, Figure 8 l600 855 ns
tPLH Receiver Input to RO2 RE = 0, Figure 3, Figure 8 30 ns
tPHL Receiver Input to RO2 RE = 0, Figure 3, Figure 8 30 ns
tr, tfReceiver Rise or Fall Time RE = 0, Figure 3, Figure 8 20 ns
tLZ Receiver Disable to Output Figure 3, Figure 9 30 ns
tHZ Receiver Disable to Output Figure 3, Figure 9 30 ns
tSTART Initial Start-Up Time (Note 9) 1200 ns
tTOF Data Time-Out Fault (Note 9) 1200 ns
ST1, ST2 Duty Cycle 0°C ≤ TA ≤ 70°C
–40°C ≤ TA ≤ 85°C
l
l
56
57
%
%
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = 5V, VCC2 = 5V, R = 27 (RS485) unless otherwise noted.
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: RS422 50Ω specification based on RS485 27Ω test.
Note 3: IIN is tested at VCC2 = 5V, guaranteed by design from
GND2 ≤ VCC2 ≤ 5.25V.
Note 4: Input fault conditions on the RS485 receiver are detected with a
fixed receiver offset. The offset is such that an input short or open will
result in a high data output.
Note 5: The low voltage detect faults when VCC2 or VCC drops below
VUVL and re-enables when greater than VUVH. The fault can be monitored
through the weak driver output on RE.
Note 6: Value derived from 1 second test.
Note 7: The input signals are internally sampled and encoded. The internal
sample rate determines the data output jitter since the internal sampling is
asynchronous with respect to the external data. Nominally, a 4MHz internal
sample rate gives 250ns of sampling uncertainty in the input signals.
Note 8: The maximum baud rate is 250kBd with 10% sampling jitter.
Lower baud rates have lower jitter.
Note 9: Start-up time is the time for communication to recover after a fault
condition. Data time-out is the time a fault is indicated on RE after data
communication has stopped.
Note 10: ICC measured with no load, ST1 and ST2 floating.