Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 5
V-Series Contura Sealed Rocker Switches- Contura II & III - Ordering Scheme
10 LENS
0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
1 6 8 G M T
2 7 C H N U
3 8 D J P V
4 9 E K R W
5 A F L S Y
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
9 ACTUATOR
0 No Actuator
A, B Contura II
C, D Contura III
Actuator orientation above terminals:
1
Series
2
Circuit
3
Rating
5
Illumination
6
Lamp
7
Lamp
8
Bracket
9
Actuator
10
Lens
11
Color
12
Legend
13
Legend
Orientation
14
Actuator
Lens Legend
4
Termination
V 1 A B A R 00 00D T 0 B B 0
1 SERIES
V
3 RATING 3
1 .4VA @ 28VDC Resistive
B 15A 24V
C 20A 18V
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V
N .4VA/15A 24V 11 ACTUATOR COLOR 1 AND TEXTURE
0 - No Actuator
Black Gray Red White
Soft Surface B G R W
Hard Surface C H S Y
13 LEGEND ORIENTATION
0 No legend (used with codes 11-18 in selection 12)
1 Orientation 1
2 Orientation 2
3 Orientation 3
4 Orientation 4
14 ACTUATOR LENS LEGEND
00 No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch
requires two legends. If the two legends consist of one lens and one
body legend, lens legend must be specied in selection 12; body legend
specied in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
1,43,6
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Body legends not available on Soft surface actuators; White imprinting is standard
on black actuators; Black imprinting is standard on white, red and gray actuators.
Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
4 Contura II available with two square lenses. Consult factory for details.
2 CIRCUIT
Terminal Connections as viewed
( )
- momentary
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only.
1 - - 4 1 - - 4
2 - - 5 2 - - 5
3 - - 6 3 - - 6
10 - - 9
Position: 1 2 3
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF
2 B (ON) NONE OFF
3 C ON NONE (OFF)
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON)
8 L (ON) OFF (ON)
SPECIAL CIRCUITS
H* 2 & 3 2 & 3, 5 & 4 5 & 4
G* 2 & 3, 5 & 6 2 & 3 OFF
S* 2 & 3, 5 & 6 2 & 3 1 & 2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2 & 1
E* 5 & 6 5 & 3 5 & 1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specied in
selection 4. External jumper between terminals 2 & 4 for circuit E are
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit.
4 TERMINATION / BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 5 Solder Lug no barriers No
C D Solder Lug No
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M. Do not use silicone based
lubricants to reduce terminal insertion forces during connector assembly,
as it is detrimental to function and performance.
5 ILLUMINATION
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED
lamps only
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE – –
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 6 (–)
G 7 1 INDEPENDENT 8 (+) 7 (–)
2 UP 3 (+) 7 (–)
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–)
2 INDEPENDENT 6 (+) 7 (–)
K W 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L 9 1 DOWN 3 (+) 6 (–)
M R 1 UP 3 (+) 6 (–)
N T 1 DOWN 3 (+) 6 (–)
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–)
8 FLUSH BRACKET COLOR 1, PANEL SEAL
Black White Gray
No Seal B W G
One Seal C Y H
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Red Amber Green Red
2VDC A L F R
6VDC B M G S
12VDC C N H T
24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current draw for
LED is 20ma.
12 ACTUATOR LENS OR BODY LEGENDS 2
11 ON 12 OFF 13 I 14 O
OFF ON O I
15 O O 16 O O 17 O I 18 I O
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com.