Keysight
InniiVision 3000T X-Series Oscilloscopes
Data Sheet
02 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Touch, Discover, Solve
The InniiVision 3000A X-Series redened oscilloscopes. It saw the most signal detail,
provided more functionality than any other oscilloscope, and gave you maximum
investment protection. It was also the most successful oscilloscope in Hewlett Packard,
Agilent and Keysight Technologies, Inc.’s history. The 3000T X-Series continues that
legacy.
The 3000T X-Series takes everything that was revolutionary about the A model and adds
a capacitive touch screen, a user interface designed for touch, and the exclusive Zone
touch trigger, all combined with an industry-leading uncompromised update rate of
1 million wfm/s to give you the condence that you’re seeing all of your signal detail, and
the ability to discover any issues. And the addition of new analysis capabilities help you
solve your hardest problems quickly.
The 3000T X-Series once again redenes what you can expect in a general purpose
oscilloscope by providing all of the performance and capability you need to get to
measurement insights faster:
Touch:
8.5-inch capacitive touch screen
Designed for touch interface
Discover:
Industry’s fastest uncompromised
waveform update rate
Exclusive InniiScan Zone touch trigger
Solve:
Wide range of serial decodes
6-in-1 instrument integration
Time/frequency domain correlation
Figure 1: InniiVision 3000 X-Series with MagaZoom IV smart memory technology
03 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Touch: Designed-for-touch interface and capacitive
touch screen simplify use
From the start of product development, we designed every aspect of this oscilloscope
to be seamlessly driven by a touch interface. Large, easy-to-touch targets, a graphical
user interface that adapts to show you more and be easier to touch, and a large,
sensitive, capacitive touch screen all combine to make operation quick and natural, just
like your favorite tablet devices.
Capacitive touch screen technology enables productivity
The user interface allows you to use the alphanumeric pad for quick annotation, place
waveforms or cursors in exact positions and drag docking panels across the screen to
see more measurement information.
The 3000T X-Series offers three ways to access key menus and features: touch GUI for
those that prefer tablet or smart phone touch interfaces, front panel buttons and knobs
for the traditional oscilloscope users, and Keysight Insight pull down menu for users who
prefer Windows-like operations. The 3000T X-Series also offers a “touch off” button as
well as USB mouse and keyboard support.
Touch interface simplies documentation
The availability of up to 4 annotations on screen makes it easy to highlight key items on
screen shots. Streamline documentation with the ability to input information via a
pop-up soft keyboard on the touch screen or a USB keyboard. A sidebar displays
additional information without covering the waveform graticule, and allows you to dock
and scroll through multiple measurement values. Touch gestures (like icking) make
navigating lists or moving between segment waveforms easy.
In addition to the benets of touch, free BenchVue software provides documentation
across multiple instruments at once. USB, LAN (optional) and GPIB (optional)
connectivity make oscilloscope control or pulling data and screenshots easy. And the
built-in ability to send emails when connected to the LAN allows you to email yourself a
screenshot or data le with just the press of a button.
Figure 5: See up to four annotations on screen
at once for documentation. The standard touch
screen makes inputting notes simple.
Figure 6: With the optional LAN/
VGA module you can email yourself
setups, data and screenshots.
Figure 7: A dock-able sidebar allows you to
customize how you view your measurements.
Figure 2: The industry’s rst 8.5” capacitive
touch display with large, touchable targets.
Figure 3: Side bar with movable docks
allows information to be placed on the
screen precisely where you want it for
documentation.
Redene your remote Web control oscilloscope experience.
The 3000T X-Series offers traditional control via a PC Web browser, but also supports
remote control through popular tablet devices when using the optional LAN/VGA
interface.
Figure 4: Use BenchVue for remotely
logging and plotting measurement data.
Figure 8: Remotely control the 3000T
X-Series via tablet device.
04 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Discover: The industrys fastest uncompromised
update rate increases the chance of nding anomalies
Industry-Leading Uncompromised Update Rate
If you can’t see the problem, you can’t x the problem. With an industry-leading update
rate of over one million waveforms per second, the InniiVision 3000T X-Series gives you
the highest probability of capturing random and infrequent events that you would miss
on an oscilloscope with a lower waveform update rate.
Powered by MegaZoom IV smart memory technology, the InniiVision 3000T X-Series
not only lets you see more waveforms, but it has the uncompromised ability to nd the
most difcult problems in your design under any conditions. Unlike other oscilloscopes,
uncompromised ability means:
Always-fast, responsive operation
No slowdown with logic channels on
No slowdown with protocol decoding on
No slowdown with math functions on
No slowdown with measurements on
No slowdown with vectors on
No slowdown with sinx/x interpolation on
What is waveform update rate?
As oscilloscopes acquire data, process it, and plot it to the screen, there is inevitable
“dead time,” or the time oscilloscopes miss signals completely. In general, the faster the
waveform update rate, the shorter the dead time. The shorter the dead time, the more
likely an oscilloscope is to capture anomalies and infrequent events. This is why it is
important to select an oscilloscope with a fast waveform update rate. Figures 7 and 8
demonstrate the difference between a slower update rate and a faster update rate.
Figure 9: Other vendor’s oscilloscope with 50,000 waveforms/second. A long dead time decreases
your chances of capturing infrequent events.
Figure 10: InniiVision 30000T X-Series with 1,000,000 waveforms/second. A short dead time
increases your chancs of capturing infrequent events.
05 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
But all specs aren’t equal.
Many vendors claim an update rate specication, but that is only in a special mode, or
without any features turned on. Table 1 shows the 3000T X-Series’ update rate versus a
competing oscilloscope.
While all scopes update rate will vary to some degree by the timebase setting, it is
critical that the update rate remain constant regardless of the functionality you are using
within the oscilloscope.
10 ns/div
Keysight
3000T X-Series
Tektronix
MDO3000 Series
Update Rate Probability Update Rate Probability
Max w/ no features on 1,114,000 94% 281,000 50%
Max w/ digital ch on 1,101,000 94% 132 0.03%
Max w/ measurements on 1,114,000 94% 2,200 0.55%
Max w/ FFT on 1,114,000 94% 2,200 0.55%
Max w/ serial on 1,100,000 94% 1,800 0.45%
Max w/ search on 1,113,000 94% 2,200 0.55%
Max w/ ref wfms on 1,113,000 94% 2,200 0.55%
Table 1: Measured update rate between the 3000T X-Series and the Danaher Tektronix MDO3000.
Note how the update rate uctuates wildly on the MDO3000 based on different settings/features.
Why is an uncompromised update rate important?
When debugging or troubleshooting a project, it is important that you see as much signal
detail as possible. A fast update rate is just part of the overall equation to determine the
likelihood of seeing an anomaly. The frequency of the anomaly, the timebase setting of
the oscilloscope and the amount of time you allow the oscilloscope to see the anomaly
all come in to play:
Therefore, it is important to select an oscilloscope with the fastest uncompromised
update rate to allow enough time to increase your chances of seeing the glitch. In Table
1, in addition to the measured update rate, we show the probability of seeing a glitch that
happens 5 times a second while allowing the oscilloscope to acquire for 5 seconds. With
the 3000T X-Series you maximize your chances of seeing the infrequent glitch. With the
competing scope, if you are using any of the other features like measurements, or search
or digital channels, the update rate slows considerably. The only option you have in this
case is to allow the oscilloscope to run longer. For example, if you are using digital
channels you’ll have to let the scope run over 8,000 times longer to get a similar
probability to the uncompromised update rate of the 3000T X-Series. That’s almost 12
hours of time versus 5 seconds!
Pt = 100 x (1-[1-RW](U x t))
where
Pt = Probability of capturing anomaly in “t” seconds
t = Observation time
U = Scope’s measured waveform update rate
R = Anomalous event occurance rate
W = Display acquisition window = Timebase setting x 10
06 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
MegaZoom IV smart memory technology enables uncompromised
update rate
Traditionally, CPU processing was the major bottleneck for oscilloscope waveform
update rate and responsiveness. Typically, the CPU handles interpolations, logic channel
plotting, serial bus decoding, measurements and more, and the waveform update rate
drops dramatically as these features are turned on.
The InniiVision 3000T X-Series requires minimum support from a CPU, as most core
operations are handled by Keysight proprietary technology, the MegaZoom IV smart
memory ASIC. MegaZoom includes hardware serial decoders and hardware mask/limit
testing capability, plots analog and digital data directly to the display, supports GUI
operation, and integrates additional instruments like the WaveGen function/arbitrary
waveform generator.
Figure 11. The 3000T X-Series oscilloscopes’ uncompromised responsiveness, speed and waveform
update rate are enabled by the MegaZoom IV, smart memory ASIC. The CPU is not used for core
waveform operations.
07 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Discover: Excellent signal integrity allows you to see more signal
detail
The 3000T X-Series has excellent signal integrity, including full bandwidth to 1 mV/div
and the ability to get up to 12-bits of resolution using the high resolution acquisition
mode.
Some oscilloscopes in this class limit their bandwidth at smaller volt-per-division set-
tings without on-display user notications. This is likely to keep the noise acceptable at
lower volt-per-division settings.
Table 2 shows a comparison of the typical noise oor at 20 μ/div between the normal
and high resolution mode. You will notice that the noise oor performance improves as
much as ve times.
Figure 12: High resolution mode allows you to lower your noise and increase your resolution up to
12-bits
50 Ω 1 GHz Bandwidth Vrms measurement (units = mV)
Vertical setting Normal mode High resolution mode Notes
1 mV 0.277 0.072 Some scopes' bandwidth automatically limited to 150 MHz
2 mV 0.277 0.072 Some scopes' bandwidth automatically limited to 350 MHz
5 mV 0.297 0.081 Some scopes' bandwidth automatically limited to 500 MHz
10 mV 0.352 0.810
20 mV 0.597 0.102
50 mV 1.500 0.340
100 mV 2.560 0.480
200 mV 5.500 1.050
500 mV 15.200 3.630
1 V 26.000 4.830
Table 2: Noise comparison between the normal and high-resolution mode at 20 μ/div
08 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Discover: Industry exclusive zone touch trigger makes triggering
simple
An uncompromised update rate allows you to see an anomaly, but to continue the debug
process you have to isolate it. Setting up a trigger has been a challenge since
oscilloscopes introduced a triggered waveform. While oscilloscopes have added more
and more triggering capability over the years, setting up triggers has remained complex
at best and impossible at worst.
Zone touch trigger eliminates the complexity of setting up advanced triggers. Now, if you
can see the event on the display of the oscilloscope, you can trigger on it just by drawing
a box on the signal you want to isolate.
See how easy Zone touch triggering can be with these examples.
Traditional Scopes with Advanced Triggers
(assuming the update rate is fast enough to see
what you want to trigger on):
1. Determine what trigger makes the most sense for the
signal you are trying to isolate. In this case, we’ll try a
rise-time trigger rst.
2. Select cursors
3. Move cursor a to 10% level
4. Move cursor b to 90% level on the non-monotonic edge
5. Obtain the delta time (rise time) between the cursors
6. Select trigger menu
7. Press trigger type
8. Select Rise/Fall time Trigger
9. Select your source
10. Select your slope
11. Select when you want it to trigger – is it less than,
greater than, equal to, not equal to. We’ll select greater
than.
12. Dial in the “greater than” setting to the measured rise
time
13. Adjust your low threshold to the 10% level
14. Adjust your high threshold to the 90% level
Steps to isolate a non-monotonic edge:
3000T X-Series:
1. Draw box on non-monotonic edge
2. Select “must intersect
In some cases you may have to select the appropriate source
if it wasn’t already selected.
09 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Traditional Scopes with Advanced Triggers
(assuming the update rate is fast enough to see
what you want to trigger on):
1. Determine what trigger makes the most sense for the
signal you are trying to isolate. In this case, we’ll use a
runt trigger rst.
2. Select trigger menu
3. Press trigger type
4. Select runt Trigger
5. Select your source
6. Select the runt’s polarity
7. Adjust your low threshold to below the runt
8. Adjust your high threshold to above the runt
9. Select when you’ll trigger – in this case, we want to
trigger on the exact pulse width of the runt
10. Select cursors
11. Move cursor a to the rising edge of the pulse at the
50% mark
12. Move cursor b to the falling edge of the pulse at the
50% mark
13. Obtain the delta time (pulse width) between the cursors
14. Adjust the runt width to be equal to the pulse width
that was measured
Steps to trigger on a runt signal:
3000T X-Series:
1. Draw box on the runt
2. Select “must intersect
3. Draw a second box if needed to further isolate the runt
from other runts
4. Select “must intersect” or “must not intersect
In some cases you may have to select the appropriate source
if it wasn’t already selected.
10 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Discover: Standard segmented smart memory al-
lows you to capture longer periods of time at high
sample rates
Acquisition memory size is an essential oscilloscope specication
because it determines sustainable sample rate and the amount
of time you can capture in a single acquisition. In general, longer
memory is better. However, no memory will always be long
enough to capture all the signals you need, especially when
capturing infrequent anomalies, data bursts, or multiple serial
bus packets. Segmented memory acquisition lets you selectively
capture and store important signal activity without capturing
unimportant signal idle time. In addition, it provides a time stamp
of each segment relative to the rst trigger event to enable
analysis of the frequency of the event. Segmented memory comes
standard on the 3000T X-Series.
Figure 13 shows segmented memory successfully capturing 100
small and large glitch events at 5 GSa/s in 47 seconds. Traditional
memory architecture would require almost 203 Gpts of memory
to accomplish the same result! This memory is not available on
any scope in the market.
Figure 13. Segmented memory reveals different types of glitches are taking place.
Figure 13a: Screen showing an overlay of all 100 segments for worst case
waveform analysis.
Furthermore, segmented memory discovered that the worst
offender glitch happened 40 seconds from the rst trigger event,
or at the 95th glitch. It also found out a unique glitch took place
13 seconds after the rst glitch. As shown in gure 13a, you can
overlay all segments to have a comprehensive view as well.
11 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Discover: Dedicated search and navigation helps you navigate deep
memory
Parametric and serial bus search and navigation comes standard on the 3000T X-Series
oscilloscopes. When you are capturing long, complex waveforms using an oscilloscope’s
acquisition memory, manually scrolling through stored waveform data to nd specic
events of interest can be slow and cumbersome. With automatic search and
navigation capability, you can easily set up specic search criteria and then quickly
navigate to “found and marked” events. Available search criteria include edges, pulse
width (time-qualied), rise/fall times (time-qualied), runt pulses (time-and
level-qualied), frequency peaks (FFT function, threshold and excursion qualied), and
serial bus frames, packets, and errors.
Close-up on buttons on the front panel of the scope. Alternatively, you also can use the touch
navigation control.
Figure 14: The 3000T X-Series was set up to capture clock signals for FFT analysis. Using the
search and navigation capability, the scope was able to nd, mark (white triangles) and quickly
navigate to the rst 11 frequency peaks occurrences. You can sort it in the order of frequency or
amplitude.
12 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Solve: Integrated hardware-based serial decoding and triggering
(option) makes easy work of low speed serial buses
Keysight InniiVision oscilloscopes, including the new 3000T X-Series, use
hardware-based serial protocol decoding. Some other vendors use software
post-processing techniques to decode serial packets⁄ frames, and therefore have slow
waveform and decode capture rates and could miss critical events and errors due to a
long dead-time. Faster decoding with hardware-based technology enhances the
probability of capturing infrequent serial communication errors.
After capturing serial bus communication, you can easily perform a search operation
based on specic criteria and then quickly navigate to bytes/frames of serial data that
satisfy that search criteria. The 3000T X-Series can decode two serial buses
simultaneously using hardware based decoding, and display the captured data in a time
interleaved “lister” display.
Serial protocol decoding can be used simultaneously with segmented memory and
Zone touch triggering. The 3000T X-Series has the most decode/trigger options in this
class of instrument including: I²C, SPI, RS232/422/485/UART, CAN, CAN-FD, CAN-dbc,
LIN, LIN symbolic, SENT, FlexRay, MIL-STD 1553, ARINC 429, and I²S.
Figure 15: I2C decode and
trigger
Figure 16: RS232 decode
and trigger
Figure 17: CAN-FD decode
and trigger
Figure 18: SPI 4wire
decode and trigger
Figure 19: Multi-bus time
aligned decode
SERIAL DECODE AND
TRIGGER OPTIONS
The 3000T X-Series supports a
range of different serial decode and
trigger options including:
I2C
SPI (2/3/4 wire)
RS232/422/485/UART
CAN
CAN-dbc
CAN-FD
LIN
LIN symbolic
SENT
FlexRay
MIL-STD 1553
ARINC 429
I2S
Solve: Segmented smart memory combined with protocol analysis
enables insights over long periods of time
Segmented memory works in conjunction with any of the optional serial protocol
decodes. For example, by setting the trigger condition to “SENT serial bus error,
segmented memory captures and stores only SENT pulse period error packets and
stitches together each segment for easy viewing of the decoded data in the lister. You
can quickly compare time tags to discover time intervals between errors.
Figure 20: Segmented memory being used in conjunction with SENT bus serial decode resulting in
maximum insight to the serial bus
13 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Solve: Dedicated frequency/spectrum analysis allows you to
time-correlate analog, digital, and frequency domain signals in a
single instrument
Viewing the frequency content of waveforms is greatly simplied by a dedicated FFT
button and level adjustment knobs. Pop up keypads make inputting start, stop, span and
center frequency easy. And the new problem solving feature called “gated FFT, unique
in this class of instrument, lets you time correlate the analog, digital, and frequency
domain to aid in analysis and debug. In addition, there are new capabilities for peak
searching, max and min hold and averaging of FFTs to increase dynamic range.
When gated FFT is on, the oscilloscope goes into zoom mode. The FFT analysis shown in
the zoomed (bottom) window is taken from the period of time indicated by the zoom box
in the main (top) window. In the gated FFT mode, touch and ick the zoom box through
the acquisition to investigate how the FFT analysis changes over time, correlating the RF
phenomenon with the analog and digital phenomenon.
Figure 21a through 21d show a simple gated FFT example observing a RF signal
frequency transition from 400 MHz to 200 MHz, time correlated to both the SPI
controlling signal (digital) and a VCO enable signal (analog). Note, you can also visualize
the RF signal itself in the time domain to gain additional insight such as a gap in the RF
time domain waveform.
Figure 21a: Triggered on a SPI command, the RF signal is still at 400 MHz
as indicated in the frequency peak search result lister
Figure 21b: No RF activities in this zoomed time
Figure 21c: Start observing the RF signal at 200 MHz. You can validate
this from the RF analog waveform as well
Figure 21d: RF signal settled down at 200 MH as indicated in the search
lister
14 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Solve: Standard advanced math capabilities allow new views of
signals
Advanced math analysis provides a variety of additional math functions and comes
standard on the 3000T X-Series. Additionally, math functions can be nested to provide
additional insight into your designs. You can create up to two math functions, with one
math function and FFT displayed at a time.
ADVANCED MATH
The 3000T X-Series supports up to two math functions with an assortment of
operators, transforms, lters and visualizations:
Operators
Add, subtract, multiply, divide
Transforms
Differentiate, integrate
FFT
Ax + B
Squared, square root
Absolute value
Common logarithm, natural logarithm
Exponential, base 10 exponential
Filters
Low-pass lter, high-pass lter
Averaged value
Smoothing
Envelope
Visualizations
Magnify
Max and min hold
Measurement trend
Chart logic bus timing, chart logic bus state
MEASUREMENTS
The 3000T X-Series supports 38 automated measurements:
Voltage
Peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, pre-shoot,
average- N cycles, average- full screen, DC RMS- N cycles, DC RMS- full screen,
AC RMS- N cycles, AC RMS- full screen (standard deviation), ratio- N cycles,
ratio- full screen
Time
Period, frequency, counter, + width, - width, burst width, duty cycle, bit rate, rise
time, fall time, delay, phase, X at min Y, X at max Y
Count
Positive pulse count, negative pulse count, rising edge count, falling edge count
Mixed
Area- N cycles, area- full screen
Counter
Built-in frequency counter
Solve: Class leading measurements provide quick answers
Automatic measurements are the essential tool of an oscilloscope. In order to make
quick and efcient measurements, the 3000T X-Series provides 37 powerful automatic
measurements and can display up to 8 at a time. Measurements can be gated by auto
select, main window, zoom window, or cursors and include full statistics.
15 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Solve: 6-in-1 integration allows new measurement possibilities
In addition to the class leading oscilloscope and powerful serial protocol analysis
capabilities, the 3000T X-Series offers four additional integrated instrument capabilities
not always found in this class of oscilloscope.
Integrated mixed signal oscilloscope (MSO - optional)
The 3000T X-Series offers 16 optional, integrated and upgradable digital channels.
Digital content is everywhere in today’s designs and traditional 2 and 4 channel
oscilloscopes do not always provide enough channels for the job at hand.
With an additional 16 integrated digital channels, you now have up to 20 channels of
time-correlated acquisition and viewing on the same instrument. In addition to offering
powerful triggering across the analog and digital channels, this also gives you additional
channels to use for serial decode and triggering. And if you buy a 2 or 4 channel DSO,
you can upgrade it at any time to an MSO with a software license.
Figure 24: Optional digital channels allow a timing view of up to 16 channels. Tightly integrated,
they work with the analog triggers and serial triggers/decoding
16 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Integrated WaveGen: Built-in 20 MHz function/arbitrary waveform
generator (optional)
The 3000T X-Series offers an integrated 20 MHz function/arbitrary waveform generator,
available with modulation support (DSOX3WAVEGEN). The function generator provides
stimulus output of sine, square, ramp, pulse, DC, Sinc (x), exponential rise/fall, cardiac,
Gaussian Pulse and noise waveforms to your device under test. The modulation feature
supports AM, FM, and FSK modulations with modulation shapes of sine, square, and
ramp. The generator can output a continuous or a single-shot waveform. With AWG
functionality, you can store waveforms from analog channels or reference memory to the
arbitrary memory and output from WaveGen. Then easily create or edit the waveform
using the built-in editor via touch and the large screen or by using Keysight’s Benchlink
Waveform Builder software: www.keysight.com/nd/33503.
Integrated DVM: Optional quick tester - 3-digit
digital voltmeter
You can add an integrated 3-digit voltmeter (part of the
DSOXT3DVMCTR option) to your 3000T X-Series oscilloscope.
The voltmeter operates through the same probes as the
oscilloscope channels. However, the DVM measurements are
made independently from the oscilloscope acquisition and
triggering system so you can make both the DVM and triggered
oscilloscope waveform captures with the same connection. The
voltmeter results are always displayed, keeping these quick
characterization measurements at your ngertips.
Figure 25: Optional arbitrary waveform generator provides easy access to stimulus. The integrated
arbitrary waveform generator makes capturing, modifying and replaying signals simple.
Figure 26: DVM and counter takes advantage of separate signal paths
to provide measurements without a trigger, while still using the scope
probes.
17 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Integrated frequency measurements: Optional 8-digit counter and
totalizer
Traditional oscilloscope counter measurements offer only ve or six digits of resolution,
which may not be enough for the most critical frequency measurements are being made.
With the 3000T X-Series’ optional 8-digit counter (part of the DSOXT3DVMCTR option),
you can see your measurements with the precision you would normally expect only from
a standalone counter. Because the integrated counter measures frequencies up to a wide
bandwidth of 1.0 GHz, you can use it for many high-frequency applications as well.
The totalizer feature of the DSOXT3DVMCTR counter option adds another valuable
capability to the oscilloscope. It can count the number of events (totalize), and it also can
monitor the number of trigger-condition-qualied events. The trigger-qualied events
totalizer does not require an actual trigger to occur. It only requires a
trigger-satisfying event to take place. In other words, the totalizer can monitor events
faster than the trigger rate of a scope, as fast as 25 million events per second (a
function of the oscilloscope’s holdoff time, which has the minimum of 40 ns). Figures 27
shows example of a totalizer counting the number of CAN-FD CRC delimiter bit error
packets that took place in a design.
See www.keysight.com/nd/DSOXDVMT3CTR for more information
Figure 27: Totalizer counts the number of events. In addition, it can count the number of
trigger-condition-qualied events as fast as 25 million events a second
18 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Solve: Hardware accelerated mask/limit testing (option) makes it
easy to see the performance of your device
Whether you are performing pass/fail tests to specied standards in manufacturing or
testing for infrequent signal anomalies, mask/limit testing can be a valuable productivity
tool (DSOX3MASK). The 3000T X-Series features powerful hardware-based mask testing
that can perform up to 270,000 tests per second. You can select multiple test criteria,
including the ability to run tests for a specic number of acquisitions, a specied time, or
until detection of a failure.
See www.keysight.com/nd/DSOX3MASK for more information.
Figure 28: Hardware accelerated mask testing allows testing against a golden waveform or user
created mask to nd violations. In this example we captured over 5M tests in only 30 seconds
Solve: Integrated power measurements and analysis (option) make
short work of power measurements
When you are working with switching power supplies and power devices, the power
measurements application (DSOX3PWR) provides a full suite of power measurements
and analysis in the oscilloscope.
Included with the DSOX3PWR is a license for the U1881A PC-based power analysis
software package, which provides additional ofine measurements and report
generation.
See www.keysight.com/nd/DSOX3PWR for more information.
In addition there are several power specic probes that make analysis of your power
supplies (e.g. switch mode power supplies) and power consuming devices (e.g. batteries)
easy.
Figure 29a: Integrated power measurements make quick work of analyz-
ing power producing and power consuming devices
Figure 29b: New control loop response analysis (bode plot) shows the
gain/phase plot over frequency sweep
19 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Solve: Innovative power rail probe (option) allows enhanced views.
The power rail noise, ripple, and transients measurements can be challenging due to
required offset range and mV sensitivity. With its ±24 V offset range, ultra-low noise 1:1
attenuation ratio, and 2-GHz bandwidth, the N7020A power rail probe is for users
making critical power integrity measurements that need mV sensitivity on their DC
power rails.
Figure 30a: 3000T X-Series and N7020A acquire not only the power rail
ripples but the high frequency transients as well.
Figure 31
Solve: Video analysis (option)
Whether you are debugging consumer electronics with HDTV or characterizing a design,
the HDTV measurement application (DSOX3VID) provides support for a variety of HDTV
standards for triggering and analysis.
See www.keysight.com/nd/DSOX3VID for more information.
Figure 30b: N7020A Power Rail Probe
20 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
While the “Touch, Discover, Solve” elements of the scope highlight the key features that
will make it easy to debug and troubleshoot your device, there are other features that
you may also want to consider when choosing your next oscilloscope.
Total cost of ownership:
The 3000T X-Series offers an extremely low cost of ownership. Between the standard
3yr warranty, an industry leading mean time between failure (MTBF) of over 250,000
hours and a market-leading calibration period of 3 years, you can rest assured that your
investment in a 3000T X-Series will be protected for years to come. In addition, because
needs change over time, you can purchase just what you need today and then upgrade
the scope’s bandwidth or measurement application easily over time as your projects
evolve.
Educator and Training Kit:
Have new hires that need to quickly become familiar with the scope? Or are you a
professor that wants to teach your students what an oscilloscope is and how to perform
basic measurements? The optional Educator’s Oscilloscope Training Kit (DSOXEDK)
makes that easy. It includes training tools created specically for electrical engineering
and physics undergraduate students and professors. It contains an array of
built-in training signals, a comprehensive oscilloscope lab guide and tutorial written
specically for the undergraduate student and an oscilloscope fundamentals PowerPoint
slide set for professors and lab assistants.
For more information, refer to: www.keysight.com/nd/EDK.
21 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Built-in features to help the infrequent user:
In addition to the optional educator’s training kit, the oscilloscope includes a localized
front panel and GUI available in 15 languages, along with an integrated (and localized)
help system. Just hold any hard key or soft panel button and a brief overview will appear
that explains how to use that feature.
30-day trial license:
The 3000T X-Series comes with a one-time 30-day, all optional-features trial license.
You can choose to start the 30-day trial at any time. In addition you can redeem
individual optional feature 30-day trial licenses at any time by visiting
www.keysight.com/nd/30daytrial. This enables you to receive in effect 60 days of trial
license of each optional feature.
Next generation probing:
All 3000T X-Series come standard with a newly designed, very robust 500 MHz 10:1
passive probe per channel. In addition, MSOs include a newly designed cable with a
exible cable management system that makes probing with the 16-digital channels easy.
LOCALIZED GUI AND
FRONT PANEL OPTIONS
The 3000T X-Series supports 15
different languages:
English
Japanese
Simplied Chinese
Traditional Chinese
Thai
Korean
German
French
Spanish
Russian
Portuguese
Italian
Polish
Czech
Turkish
22 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
“Designed for Touch”.
8.5 inch capacitive
touch screen with
gesture support.
6-in-1 instruments helps you solve your problems: oscilloscope chan-
nels digital channels, serial protocol analysis, WaveGen, DVM, and 8-digit
counter-totalizer. Fully upgradeable including bandwidth.
Uncompromised 1,000,000 waveform per second update rate minimize
the dead-time for maximum probability of capturing infrequent events
and anomalies.
Built-in features to help the infrequent user - GUI available in 15
languages.
Display up to 8 measurements
simultaneously, without compromising other key info. 38 automatic
measurements. Gated by cursors supported.
Integrated DVM and 8-digit counter with totalizer. Wide coverage
of application and serial protocol solutions including CAN-FD and
SENT trigger and decode.
Both USB keyboard and mouse are supported in 3000T X-Series for
additional ease of use.
Standard segment memory with event lister powered by
MegaZoom IV smart memory technology intelligent capture of just
the signals of interest.
23 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Not a touch screen
fan? Turn off the touch
screen from a front
panel button.
Zone touch trigger, if you
can see it, you can trigger
on it by drawing a box.
Recongurable Docking panels with
the capacitive touch screen adds a
new dimension to the usability.
Standard advanced math displays
FFT and one math functions for
your deep analysis.
Standard Gated FFT
for your time
correlated analog,
digital, and frequency
domain signal analysis.
Build in WaveGen function/arbitrary
generator allows you to capture and
regenerate the signals immediately.
AutoProbe interface supports various
active, differential, and current probes.
Independent knobs
per channel for fast
operation. All front
panel knobs are
push-able for access
to common controls.
24 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Conguration
Step 1.
Choose your bandwidth and number of channels
1. For example, if you chose 1 GHz, 4+16 channels, the model number will be MSOX3104T.
Step 2.
Tailor your oscilloscope with integrated capabilities and measurement applications to save time and
money. After purchase upgrade model numbers are listed below (values in parentheses are
factory-installed option numbers).
Description Model number
Oscilloscope features
MSO upgrade DSOXT3MSO*
Serial protocols
Embedded serial triggering and analysis (I²C, SPI) DSOX3EMBD (-LSS)
Computer serial triggering and analysis (RS232/UART) DSOX3COMP (-232)
Sensor triggering and analysis (SENT) DSOXT3SENSOR (-SEN)*
Automotive serial triggering and analysis (CAN/CAN-FD/CAN-dbc/LIN/LIN symbolic) DSOXT3AUTO (-AMS)*
FlexRay serial triggering and analysis DSOX3FLEX (-FLX)
Audio serial triggering and analysis (I²S) DSOX3AUDIO (-SND)
MIL-STD 1553 and ARINC 429 serial triggering and analysis DSOX3AERO (-AER)
Measurement applications
WaveGen 20 MHz arbitary/function generator DSOX3WAVEGEN (-001)
Integrated digital voltmeter and 8-digit counter DSOXT3DVMCTR (-DVM)*
Power analysis application DSOX3PWR (-PWR)
Mask limit testing DSOX3MASK (-LMT)
Enhanced video/TV application package DSOX3VID (-VID)
Productivity tools
Education and training kit DSOXEDK (-EDK)
Inniium Ofine oscilloscope analysis software N8900A
BenchVue for data capture Free Download 34840B (version 2.6 and higher)
Vector signal analyzer software 89601B (version 20 and higher)
Benchlink waveform builder pro and basic 33503A
Application bundle
DSOXT3APPBNDL*
(include DSOX3AERO, DSOX3AUDIO, DSOXT3AUTO,
DSOX3COMP, DSOX3EMBD, DSOX3FLEX, DSOX3MASK,
DSOX3PWR, DSOXT3SENSOR, DSOX3VID, DSOX3WAVEGEN,
DSOXT3DVMCTR, DSOXEDK)
3000 X-Series specication overview
3012T 3014T 3022T 3024T 3032T 3034T 3052T 3054T 3102T 3104T
Bandwidth (-3dB) 100 MHz 200 MHz 350 MHz 500 MHz 1 GHz
Calculated rise time
(10-90%) ≤ 3.5 ns ≤ 1.75 ns ≤ 1 ns ≤ 700 ps ≤ 450 ps
Input channels DSOX 2 4 2 4 2 4 2 4 2 4
MSOX 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16
* These options are compatible with the 3000T X-Series, but are not compatible with the 3000A X-Series.
25 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Step 4.
Add the nal touches
Conguratiion
Step 3.
Choose your probes
For a complete list of compatible probes, visit www.keysight.com/nd/scope_probes. In general, the 3000T X-Series supports up to
two active probes simultaneously with some exceptions. Contact Keysight for more detail.
Probes
N2843A Passive probe 500 MHz, 10:1, 1 MΩ, 11 pF Standard (1 per channel)
N2756A 16 digital channel MSO cable Standard on MSOX models & DSOXT3MSO
N2870A Passive probe 35 MHz, 1:1, 1 MΩ Optional
10076C Passive probe 500 MHz 100:1 attenuation (4kV) Optional
N2804A 300 MHz 100:1 Differential probe, 4 MΩ, 4 pF, ±300V DC+peakAC Optional
N2805A 200 MHz 100:1 Differential probe, 4 MΩ, 4 pF, ±100V, 5 m cable Optional
N2790A 100 MHz 50:1/500:1 High voltage differential probe, 8 MΩ, 3.5 pF, ±1,400 V Optional
N2795A Active single-ended probe 1 GHz 1 pF 1 MΩ with AutoProbe Optional
N2797A Active single-ended probe 1.5 GHz extreme temperature Optional
N2750A InniiMode differential probe 1.5 GHz 700 fF 200 kΩ with AutoProbe Optional
N2790A Differential active probe 100 MHz, ±1.4 kV with auto probe Optional
N2791A Differential active probe 25 MHz, ±700 V Optional
N2818A 200 MHz 10:1 Differential Probe with AutoProbe Optional
N2819A 800 MHz 10:1 Differential Probe with AutoProbe Optional
1147B AC/DC current probe 50 MHz 15 A with auto probe Optional
N2893A AC/DC current probe 100 MHz 15 A with auto probe Optional
N2820A 2-channel high-sensitivity current probe 50 uA - 5 A Optional
N2821A 1-channel high-sensitivity current probe 50 uA - 5 A Optional
N7020A Power Rail Probe 2 GHz, 1:1, ± 24V offset range at 50 Ω Optional
Recommended accessories
DSOXLAN LAN/VGA connection module Optional
DSOXGPIB GPIB connection module Optional
N2747A Front panel cover Optional
N6456A Rack mount kit Optional
N6457A Soft carrying case with front panel cover Optional
Hard transit case CaseCruzer 3F1112-1510J
(available from http://www.casecruzer.com/)
Optional
26 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
DSO and MSO 3000 X-Series oscilloscopes
Vertical system analog channels
Hardware bandwidth limits Approximately 20 MHz (selectable)
Input coupling AC, DC
Input impedance Selectable: 1 MΩ ± 1% (14 pF), 50 Ω ± 1.5%
Input sensitivity range 100 MHz ~ 500 MHz models: 1 mV/div to 5 V/div2 (1 MΩ and 50 Ω)
1 GHz models: 1 mV/div to 5 V/div2 (1 MΩ), 1 mV/div to 1 V/div (50 Ω)
Vertical resolution 8 bits (measurement resolution is 12 bits with averaging)
Maximum input voltage 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
With N2843A 10:1 probe: 300 Vrms
Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz. Then de-rates at 20 db/dec until 6 Vpk
DC vertical accuracy ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]2
DC vertical gain accuracy1± 2.0% full scale2
DC vertical offset accuracy ± 0.1 div ± 2 mV ± 1% of offset setting
Channel-to-channel isolation > 100:1 from DC to maximum specied bandwidth of each model
(measured with same V/div and coupling on channels)
Offset range ± 2 V (1 mV/div to 200 mV/div)
± 50 V (> 200 mV/div to 5 V/div)
1. Denotes warranted specications, all others are typical.
2. Specications are valid after a 30-minute warm-up period and ± 10 °C from rmware calibration temperature. 1 mV/div and 2 mV/div are a magnication of
4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 1 mV div and 2 mV/div sensitivity setting.
Vertical system digital channels
Digital input channels 16 digital (D0 to D15. pod 1: D7 ~ D0, Pod 2: D15 ~ D8)
Thresholds Threshold per pod
Threshold selections TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (–1.3 V), user-dened (selectable by pod)
User-dened threshold range ± 8.0 V in 10 mV steps
Maximum input voltage ± 40 V peak CAT I; transient overvoltage 800 Vpk
Threshold accuracy1± (100 mV + 3% of threshold setting)
Maximum input dynamic range ± 10 V about threshold
Minimum voltage swing 500 mVpp
Input impedance 100 kΩ ± 2% at probe tip
Input capacitance ~8 pF
Vertical resolution 1 bit
3000T X-Series specication overview
3012T 3014T 3022T 3024T 3032T 3034T 3052T 3054T 3102T 3104T
Bandwidth 1 (-3dB) 100 MHz 200 MHz 350 MHz 500 MHz 1 GHz
Calculated rise time (10-90%) ≤ 3.5 ns ≤ 1.75 ns ≤ 1 ns ≤ 700 ps ≤ 450 ps
Input channels DSOX 2 4 2 4 2 4 2 4 2 4
MSOX 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16
Maximum sample rate 5 GSa/s half channels, 2.5 GSa/s all channels
Maximum memory depth Standard 4 Mpts, Standard segmented memory
Display size and type 8.5-inch capacitive touch gesture-enabled display
Waveform update rate > 1,000,000 waveforms per second
27 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
1. Denotes warranted specications, all others are typical. Specications are valid after a 30-minute warm-up period and ± 10 °C from rmware calibration
temperature.
3000T X-Series specication overview
3012T 3014T 3022T 3024T 3032T 3034T 3052T 3054T 3102T 3104A
Time base range 5 ns/div to 50 s/div 2 ns/div to 50 s/div 1 ns/div to 50 s/div 500 ps/div to 50 s/div
Time base accuracy1±1.6 ppm + aging factor (1st year: ±0.5 ppm, 2nd year: ±0.7 ppm, 5 years: ±1.5 ppm, 10 years: ±2.0 ppm)
Time base delay
time range
Pre-trigger Greater of 1 screen width or 250 μs
Post-trigger 1 s to 500 s
Channel-to-channel
deskew range ± 100 ns
Δ Time accuracy
(using cursors) ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps
Modes Main, zoom, roll, XY
XY On channels 1 and 2 only. Z Blanking on Ext Trigger Input, 1.4 V threshold.
Bandwidth: Maximum bandwidth. Phase error at 1 MHz: < 0.5 degree.
Horizontal System Digital Channels
Minimum detectable pulse width 5 ns
Channel-to-channel skew 2 ns (typical); 3 ns (maximum)
Acquisition System
Maximum analog channels sample
rate 5 GSa/s half channel interleaved, 2.5 GSa/s all channel
Maximum analog channels record
length 4 Mpts half channel interleaved, 2 Mpts all channel
Maximum digital channels sample
rate 1.25 GSa/s all pods
Maximum digital channels record
length 2 Mpts (with digital channels only)
Acquisition mode Normal Default mode
Peak detect Capture glitches as narrow as 250 ps at all time base settings
Averaging Selectable from 2, 4, 8, 16, 64, ... to 65,536
High
resolution
Real time boxcar averaging reduces random noise and effectively increases vertical resolution
12 bits of resolution when ≥ 10 μs/div at 5 GSa/s or ≥ 20s/div at 2.5 GSa/s
Segmented Segmented memory optimizes available memory for data streams that have long dead times between activity.
Maximum segments = 1000. Re-arm time = 1 μs (minimum time between trigger events).
Time mode Normal Default mode
Roll Displays the waveform moving across the screen from right to left. Available at the time base 50 ms/div or slower
XY Displays the volts-versus-volts display. Time base can be set from 200 ns/div to 50 ms/div.
28 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
Trigger system
Trigger sources Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
Trigger modes Normal (triggered): requires trigger event for scope to trigger
Auto: triggers automatically in absence of trigger event
Single: triggers only once on a trigger event, press [Single] again for scope to nd another trigger event, or
press [Run] to trigger continuously in either Auto or Normal mode
Force: front panel button that forces a trigger
Trigger coupling DC: DC coupled trigger
AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); <50 Hz (external)
HF Reject: High frequency reject, cutoff frequency ~ 50 kHz
LF Reject: Low frequency reject, cutoff frequency ~ 50 kHz
Noise Reject: Selectable OFF or ON, decreases sensitivity 2x
Trigger holdoff range 40 ns to 10.00 s
Trigger sensitivity
Internal1< 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
External1200 mVpp from DC to 100 MHz
350 mVpp 100 MHz to 200 MHz
Trigger level range
Any channel ± 6 div from center screen
External ± 8 V
1. Denotes warranted specications, all others are typical.
Specications are valid after a 30-minute warm-up period and ±10 °C from rmware calibration temperature.
Trigger type selections
Zone (HW zone qualier) Trigger on user-dened zones drawn on the display. Applies to one analog channel at a time. Specify zones as
either “must intersect” or “must not intersect.” Up to two zones. > 200,000 scans/sec update rate.
Supported modes: normal, peak detect, high resolution
Also works simultaneously with the serial trigger and mask/limit test.
Edge Trigger on a rising, falling, alternating or either edge of any source
Edge then edge (B trigger) Arm on a selected edge, wait a specied time, then trigger on a specied count of another selected edge
Pulse width Trigger on a pulse on a selected channel, whose time duration is less than a value, greater than a value, or inside
a time range
Minimum duration setting: 2 ns (500 MHz, 1 GHz), 4 ns (350 MHz), 6 ns (200 MHz), 10 ns (100 MHz)
Maximum duration setting: 10 s
Range minimum: 10 ns
Runt Trigger on a position runt pulse that fails to exceed a high level threshold. Trigger on a negative runt pulse that
fails to exceed a low level threshold. Trigger on either polarity runt pulse based on two threshold settings. Runt
triggering can also be time-qualied (< or >) with a minimum time setting of 2~10 ns and maximum timesetting
of 10 s.
Minimum time setting: 2 ns (500 MHz, 1 GHz), 4 ns (350 MHz), 6 ns (200 MHz).
10 ns (100 MHz)
Setup and hold Trigger and clock/data setup and/or hold time violation. Setup time can be set from –7 s to 10 s. Hold time can
be set from 0 s to 10 ns.
Rise/fall time Trigger on rise-time or fall-time edge speed violations (< or >) based on user-selectable threshold.
Select from (< or >) and time settings range between
Minimum: 1 ns (500 MHz, 1 GHz), 2 ns (350 MHz), 3 ns (200 MHz), 5 ns (100 MHz)
Maximum: 10 s
29 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
Trigger type selections
Nth edge burst Trigger on the Nth (1 to 65535) edge of a pulse burst. Specify idle time (10 ns to 10 s) for framing.
Pattern Trigger when a specied pattern of high, low, and don’t care levels on any combination of analog, digital, or
trigger channels is [entered | exited]. Pattern must have stabilized for a minimum of 2 ns to qualify as a valid
trigger condition.
Minimum duration setting: 2 ns (500 MHz, 1 GHz), 4 ns (350 MHz), 6 ns (200 MHz), 10 ns (100 MHz)
Maximum duration setting: 10 s
Range minimum: 10 ns
Or Trigger on any selected edge across multiple analog or digital channels
Video Trigger on all lines or individual lines, odd/even or all elds from composite video, or broadcast standards
(NTSC, PAL, SECAM, PAM-M)
Enhanced Video (optional) Trigger on lines and elds of enhanced and HDTV standards (480p/60, 567p/50, 720p/50, 720p/60, 1080p/24,
1080p/25, 1080p/30, 1080p/50, 1080p/60, 1080i/50, 1080i/60).
USB Trigger on start of packet, end of packet, reset complete, enter suspend, or exit suspend. Support USB
low-speed and full-speed.
I2C (optional) Trigger at a start/stop condition or user dened frame with address and/or data values. Also trigger on missing
acknowledge, address with no accq, restart, EEPROM read, and 10-bit write.
SPI (optional) Trigger on SPI (Serial Peripherial Interface) data pattern during a specic framing period. Supports positive and
negative Chip Select framing as well as clock Idle framing and user-specied number of bits per frame.
Supports MOSI and MISO data.
RS-232/422/485/UART (optional) Trigger on Rx or Tx start bit, stop bit or data content or parity error.
I²S (optional) Trigger on 2’s complement data of audio left channel or right channel (=, ≠, <, >, > <, < >, increasing value, or
decreasing value)
CAN (optional) Trigger on CAN (controller area network) version 2.0A,2.0B, and CAN-FD (Flexible Data-rate) signals. Trigger on
the start of frame (SOF), the end of frame (EOF), data frame ID, data frame ID and data (non-FD), data frame ID
and data (FD), remote frame ID, remote or data frame ID, error frame, acknowledge error, from error, stuff error,
CRC error, spec error (ack or form or stuff or CRC), all errors, BRS Bit (FD), CRC delimiter bit (FD), ESI bit active
(FD), ESI bit passive (FD), overload frame., message, message and signal (non-FD), message and signal (FD, rst
8 bytes only)
LIN (optional) Trigger on LIN (Local Interconnect Network) sync break, sync frame ID, or frame ID and data, parity error,
checksum error, frame (symbolic), frame and signal (symbolic)
FlexRay (optional) Trigger on frame ID, frame type (sync, start-up, null, normal), cycle-repetitive, cycle-base, and errors.
MIL-STD 1553 (optional) Trigger on MIL-STD 1553 signals based on word type (Data or Command/Status), Remote Terminal Address,
data, and errors (parity, sync, Manchester encoding).
ARINC 429 (optional) Trigger and decode on ARINC429 data. Trigger on word start/stop, label, label + bits, label range, error
conditions (parity, word, gap, word or gap, all), all bits (eye), all 0 bits, all 1 bits.
SENT (optiional) Trigger and decode on SENT bus. start of fast channel message, start of slow channel message, fast channel
SC & data, slow channel message ID, slow channel message ID &data, tolerance violation, fast channel CRC
error, slow channel CRC error, all CRC errors, pulse period error, successive sync pulses error (1/64)
30 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Waveform measurements
Cursors2Single cursor accuracy:
±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
Dual cursor accuracy:
±[DC vertical gain accuracy + 0.5% full scale]1
Units: Seconds(s), Hz (1/s), Phase (degrees), Ratio (%)
Automatic measurements Measurements continuously updated with statistics. Cursors track last selected measurement. Select up to eight
measurements from the list below:
Snapshot All: measure all single waveform measurements (31)
Voltage: peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, pre-shoot, average- N cycles, average- full
screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles, AC RMS- full screen (std deviation), ratio- N cycle,
ratio- full screen
Time: period, frequency, counter, + width, - width, burst width, +duty cycle, -duty cycle, bit rate, rise time, fall time, delay,
phase, X at min Y, X at max Y
Count: positive pulse count, negative pulse count, rising edge count, falling edge count
Mixed: area- N cycles, area- full screen
Counter
(see pg 32 for 8-digit
precision counter)
Built-in frequency counter:
Source: on any analog or digital channel
Resolution: 5 digits
Maximum frequency: bandwidth of scope
Performance characteristics
1. Denotes warranted specications, all others are typical.
Specications are valid after a 30-minute warm-up period and ±10 °C from rmware calibration temperature.
2. 1 mV/div and 2 mV/div is a magnication of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 1 mV/div and 2 mV/div
sensitivity setting.
Display characteristics
Display 8.5-inch capacitive touch / gesture enabled display
Resolution 800 (H) x 480 (V) pixel format (screen area)
Graticules 8 vertical divisions by 10 horizontal divisions with intensity controls.
Format YT, XY, and Roll
Maximum waveform update rate > 1,000,000 wfms/s
Persistence Off, innite, variable persistence (100 ms - 60 s)
Intensity gradation 64 intensity levels
Waveform math
Number of math functions Two, displays FFT and one math simultaneously. Can be cascaded.
Arithmetic Add, subtract, multiply, divide, differentiate, integrate, FFT, Ax + B, squared, square root, absolute value,
common logarithm, natural logarithm, exponential, base 10 exponential, low pass lter, high pass lter, averaged
value, smoothing, envelope, magnify, max hold, min hold, measurement trend, chart logic bus (Timing or State)
Enhanced FFT Record size Up to 64 kpts resolution
Window types Hanning, Flat Top, Rectangular, Blackman-Harris
Time gated FFT Gate the time range of data for FFT analysis in the zoom view. For time and frequency domain correlated analysis.
Waveforms FFT, max hold, min hold, average
Peak search Max 11 peaks, threshold and excursion control.
Search, navigate, and lister
Type Edge, pulse width, rise/fall, runt, frequency peak, serial bus 1, serial bus 2
Copy Copy to trigger, copy from trigger
Frequency peak Source Math functions
Max # of peaks 11
Control Results order in frequency or amplitude
Result display Event lister or navigation. Manual or auto scroll via navigation or touch event lister entry to jump to a specic event.
31 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
WaveGen – Built-in function/arbitrary waveform generator (specications are typical)
WaveGen out Front-panel BNC connector
Waveforms Sine, Square, Ramp, Pulse, DC, Noise, Sine Cardinal (Sinc), Exponential Rise, Exponential Fall, Cardiac, Gaussian
Pulse, and Arbitrary.
Modulation Modulation types: AM, FM, FSK
Carrier waveforms: sine, ramp, sine cardinal, exponential rise, exponential fall, and cardiac.
Modulation source: internal (no external modulation capability)
AM:
Modulation: sine, square, ramp
Modulation frequency: 1 Hz to 20 kHz
Depth: 0% to 100%
FM:
Modulation: sine, square, ramp
Modulation frequency: 1 Hz to 20 kHz
Minimum carrier frequency: 10 Hz
Deviation: 1 Hz to carrier frequency or (2e12 / carrier frequency), whichever is smaller
FSK:
Modulation: 50% duty cycle square wave
FSK rate: 1 Hz to 20 kHz
Hop frequency: 2 x FSK rate to 10 MHz
Sine Frequency range: 0.1 Hz to 20 MHz
Amplitude atness: ±0.5 dB (relative to 1 kHz)
Harmonic distortion: –40 dBc
Spurious (non harmonics): –40 dBc
Total harmonic distortion: 1%
SNR (50 Ω load, 500 MHz BW) : 40 dB (Vpp > = 0.1 V); 30 dB (Vpp < 0.1V)
Square wave /pulse Frequency range: 0.1 Hz to 10 MHz
Duty cycle: 20 to 80%
Duty cycle resolution: Larger of 1% or 10 ns
Pulse width: 20 ns minimum
Rise/fall time: 18 ns (10 to 90%)
Pulse width resolution: 10 ns or 5 digits, whichever is larger
Overshoot: < 2%
Asymmetry (at 50% DC): ±1% ± 5 ns
Jitter (TIE RMS): 500 ps
Ramp/triangle wave Frequency range: 0.1 Hz to 200 kHz
Linearity: 1%
Variable symmetry: 0 to 100%
Symmetry resolution: 1%
Noise Bandwidth: 20 MHz typical
Sine Cardinal (Sinc) Frequency range: 0.1 Hz to 1.0 MHz
Exponential Rise/Fall Frequency range: 0.1 Hz to 5.0 MHz
Cardiac Frequency range: 0.1 Hz to 200.0 kHz
Gaussian Pulse Frequency range: 0.1 Hz to 5.0 MHz
Arbitrary Waveform length: 1 to 8k points
Amplitude Resolution: 10 bits (including sign bit)1
Repetition Rate: 0.1Hz to 12 MHz
Sample Rate: 100 MSa/s
Filter Bandwidth: 20 MHz
1. Full resolution is not available at output due to internal attenuator stepping.
32 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
1. Gaussian Pulse: 4 Vpp maximum into Hi-Z; 2 Vpp maximum into 50 Ω.
WaveGen – Built-in function/arbitrary waveform generator (specications are typical) (continued)
Frequency Sine wave and ramp accuracy:
130 ppm (frequency < 10 kHz)
50 ppm (frequency > 10 kHz)
Square wave and pulse accuracy:
[50+frequency/200] ppm (frequency < 25 kHz)
50 ppm (frequency ≥ 25 kHz)
Resolution: 0.1 Hz or 4 digits, whichever is larger
Amplitude Range:
20 mVpp to 5 Vpp into Hi-Z1
10 mVpp to 2.5 Vpp into 50 Ω1
Resolution: 100 μV or 3 digits, whichever is higher
Accuracy: 2% (frequency = 1 kHz)
DC offset Range:
±2.5 V into Hi-Z1
±1.25 V into 50 Ω 1
Resolution: 100 μV or 3 digits, whichever is higher
Accuracy (waveform modes): ± 1.5% of offset setting ± 1% of amplitude ± 1 mV
Accuracy (DC mode): ± 1.5% of offset setting ± 3 mV
Trigger output Trigger output available on Trig out BNC
Main Output Impedance : 50 Ω typical
Isolation: not available, main output BNC is grounded
Protection: overload automatically disables output
Output mode Normal
Single-shot (arbitrary, sine, ramp, sine cardinal, exp rise/fall, cardiac, Gaussian pulse)
Digital voltmeter (specications are typical)
Functions ACrms, DC, DCrms
Resolution ACV/DCV: 3 digits
Measuring rate 100 times/ second
Autoranging Automatic adjustment of vertical amplication to maximize the dynamic range of measurements.
Range meter Graphical display of most recent measurement, plus extrema over the previous 3 seconds.
Precision counter / totalizer (specication are typical)
Counter Source Any analog channel or trigger qualied event
Resolution 8 digits (8 digits for trigger qualied event)
Max frequency 1 GHz
Trig qual events 1/(trigger hold off time) for trigger qualied events (max 25 MHz, ,minimum dead time of 40 ns)
Measurement Frequency, period, totalize
Totalizer Counter size 64 bit totalizing counter
Edge Rise or fall
Gating Positive or negative level. Select from analog channels except the source.
33 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Performance characteristics
General and environmental characteristics
Power line consumption Max 100 watts
Power voltage range 100-120V, 50/60/400 Hz; 100-240V, 50/60 Hz ± 10% auto ranging
Temperature Operating: 0 to +55 °C
Nonoperating: –30 to +71 °C
Humidity Operating: Up to 80% RH at or below +40 °C; up to 45% RH up to +50 °C
Non-operating: Up to 95% RH up to 40 °C; up to 45% RH up to 50 °C
Altitude Operating: up to 4,000 m, Non-operating 15,300 m
Electromagnetic compatibility Meets EMC Directive (2004/108/EC), meets or exceeds IEC 61326-1:2005/EN
61326-1:2006 Group 1 Class A requirement
CISPR 11/EN 55011
IEC 61000-4-2/EN 61000-4-2
IEC 61000-4-3/EN 61000-4-3
IEC 61000-4-4/EN 61000-4-4
IEC 61000-4-5/EN 61000-4-5
IEC 61000-4-6/EN 61000-4-6
IEC 61000-4-11/EN 61000-4-11
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS
Safety UL61010-1 2nd edition, CAN/CSA22.2 No. 61010-1-04
Vibration Meets IEC60068-2-6 and MIL-PRF-28800; class 3 random
Shock Meets IEC 60068-2-27 and MIL-PRF-28800; class 3 random; (operating 30 g,
½ sine. 11 ms duration, 3 shocks/axis along major axis, total of 18 shocks
Dimensions 381 mm (15 in) W x 204 mm (8 in) H x 142 mm (5.6 in) D
Weight Net: 4.0 kg (9.0 lbs), shipping: 4.2 kg (9.2 lbs)
Connectivity
Standard ports One USB 2.0 hi-speed device port on rear panel. Supports USBTMC protocol.
Two USB 2.0 hi-speed host ports, front and rear panel
Supports memory devices, printers and keyboards
Optional ports GPIB, LAN (10/100Base-T), WVGA video out
Trigger out BNC connector on the rear panel. Supported modes: triggers, mask, and waveform generator sync pulse
34 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Nonvolatile storage
Reference waveform display Two internal waveforms or USB thumb drive. Displays 1 reference waveform at a time.
Data/le save Setup / image Setup (*.scp), 8 or 24-bit Bitmap image (*.bmp), PNG 24-bit image (*.png),
Waveform data CSV data (*.csv), ASCII XY data (*.csv), Binary data (*.bin), Lister data (*.csv), Reference
waveform data (*.h5), multi-channel waveform data (*.h5), Arbitrary Waveform data (*.csv)
Application data Mask (*.msk), Power harmonics data (*.csv), USB signal quality (*.html & *.bmp)
Analysis results
(*.csv)
Cursor data, measurement results, mask test statistics, search, segmented timestamps
Max USB ash drive size Supports industry standard ash drives
Set ups without USB ash drive 10 internal setups
Set ups with USB ash drive Limited by size of USB drive
Performance characteristics
Related literature
Publication title Publication type Publication number
Serial Bus Applications for Keysight InniiVision 3000 X-Series Oscilloscopes Data sheet 5990-6677EN
Power Measurements for Keysight InniiVision 3000 X-Series oscilloscope Data sheet 5990-8869EN
Mask/Waveform Limit Testing For Keysight InniiVision Series
Oscilloscopes
Data sheet 5990-3269EN
U s i n g a n O s c i l l o s c o p e T i m e G a t e d F a s t F o u r i e r T r a n s f o r m s f o r T i m e C o r r e l a t e d M i x e d D o m a i n A n a l y s i s Application note 5992-0244EN
Keysight InniiVision 3000T X-Series versus Danaher-Tektronix MDO3000 Series
Oscilloscopes
Competitive
comparison
5992-0116EN
Keysight InniiVision 3 0 00T X-Serie s Oscilloscopes Produc t Fa c t She et Product fact sheet 5992-0150EN
Triggering on Infrequent Anomalies and Complex Signals using Zone triggering Application note 5991-1107EN
Included standard with oscilloscope
Factory warranty 3-year warranty (90 days for unserialized accessories such as passive probes)
Calibration Certicate of calibration, 3-year calibration interval
Mean time before failure (MTBF) >250,000 hours
Standard secure erase
Probes
N2843A Passive probe 500 MHz 10:1 attenuation 1 per channel
N2756A 16 digital channel MSO cable 1 per scope included on all MSO models and DSOXT3MSO
Interface and built-in help language support
English, Chinese (simplied), Chinese (traditional), Czech, French, German, Italian, Japanese, Korean, Portuguese, Russian, Spanish, Polish, Thai, Turkish
Documentation CD containing localized user’s guide, service guide, and programmer’s manual
Localized power cord and overlay
For MET/CAL procedures, click on the Cal Labs solutions link below
http://www.callabsolutions.com/products/Keysight/
These procedures are FREE to customers
35 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
License Only Bandwidth Upgrade Models
3000T X-Series
DSOXT3B1T22 License only 100MHz to 200MHz upgrade, 2ch
DSOXT3B1T24 License only 100MHz to 200MHz upgrade, 4ch
DSOXT3B3T52 License only 350MHz to 500MHz upgrade, 2ch
DSOXT3B3T54 License only 350MHz to 500MHz upgrade, 4ch
License-only bandwidth upgrades and measurement applications
Ke
ysight sales
partner
Customer
Keysight software
licensing website
USB drive containing
license file
5
Email containing
attached licensed file
Entitlement
certificate Stick-0n
label sheet
Measurement Applications
DSOX3AERO MIL-STD 1553 & ARINC 429 serial triggering & analysis
DSOX3AUDIO Audio serial triggering and analysis (I2S)
DSOXT3AUTO Automotive serial triggering and analysis
(CAN/CAN-FD/LIN)
DSOX3COMP Computer serial triggering and analysis
(RS232/UART)
DSOX3EMBD Embedded serial triggering and analysis (I2C, SPI)
DSOX3FLEX FlexRay serial triggering and analysis
DSOX3MASK Mask Limit Testing
DSOXT3MSO MSO upgrade: add 16 digital timing channels
(N2756A MSO cable delivered separately)
DSOX3PWR Power analysis application
DSOXT3SENSOR Single Edge Nibble Transmission (SENT) trigger
and decode
DSOX3VID Enhanced video/TV application package
DSOX3WAVEGEN WaveGen 20 MHz AWG
DSOXT3DVMCTR Integrated digital voltmeter / 8 digit counter
DSOXEDK Education and training kit
DSOXT3APPBNDL SW application bundle license for 3000T X-Series
1. Place order for a license only bandwidth upgrade or
measurement application product to a Keysight sales
partner. If multiple bandwidth upgrade steps are needed,
order all the corresponding upgrade products required to
get from current bandwidth to desired bandwidth.
2. For measurement applications, you will receive a paper
or electronic .pdf Entitlement Certicate. For bandwidth
upgrades only, you will receive a stick-on label document
indicating upgraded bandwidth specication in addition to
a paper Entitlement Certicate.
3. Use Entitlement Certicate containing instructions and
certicate number needed to generate a license le for a
particular 3000T X-Series oscilloscope model number and
serial number unit.
4. Receive the licensed le and installation instructions via
email.
5. Copy license le (.lic extension) from email to a USB drive
and follow instructions in email to install the purchased
bandwidth upgrade or measurement application on the
oscilloscope.
6. For bandwidth upgrades only, attach bandwidth upgraded
stick-on label to front and rear panels of the oscilloscope.
Model number and serial number of the oscilloscope do
not change.
* See next page for return-to-Keysight service center upgrade process
for these products
36 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
Return-to-Keysight Service Center Bandwidth Upgrades
Return-to-Keysight Bandwidth Upgrade Models
3000T X-Series
DSOXT3B1T32U Service center 100MHz to 350MHz upgrade, 2ch
DSOXT3B1T52U Service center 100MHz to 500MHz upgrade, 2ch
DSOXT3B1T102U Service center 100MHz to 1 GHz upgrade, 2ch
DSOXT3B1T34U Service center 100MHz to 350MHz upgrade, 4ch
DSOXT3B1T54U Service center 100MHz to 500MHz upgrade, 4ch
DSOXT3B1T104U Service center 100MHz to 1 GHz upgrade, 4ch
DSOXT3B2T32U Service center 200MHz to 350MHz upgrade, 2ch
DSOXT3B2T52U Service center 200MHz to 500MHz upgrade, 2ch
DSOXT3B2T102U Service center 200MHz to 1 GHz upgrade, 2ch
DSOXT3B2T34U Service center 200MHz to 350MHz upgrade, 4ch
DSOXT3B2T54U Service center 200MHz to 500MHz upgrade, 4ch
DSOXT3B2T104U Service center 200MHz to 1 GHz upgrade, 4ch
DSOXT3B3T102U Service center 350MHz to 1 GHz upgrade, 2ch
DSOXT3B3T104U Service center 350MHz to 1 GHz upgrade, 4ch
DSOXT3B5T102U Service center 500MHz to 1 GHz upgrade, 2ch
DSOXT3B5T104U Service center 500MHz to 1 GHz upgrade, 4ch
Keysight Business
Center
Keysight sales
partner Keysight service
center
Customer
Ship scope per
instructions
Upgraded scope
shipped back
1. Place order for a return-to-Keysight Service Center
bandwidth upgrade product to a Keysight sales partner.
Shipment costs are in addition to bandwidth upgrade
product price.
2. Keysight Business Center will contact you regarding process
and timing of the Service Center installation. Continue to
use oscilloscope until contacted again later when parts are
available at Service Center.
3. Ship the oscilloscope per provided instructions to Service
Center.
4. Service Center ships back upgraded oscilloscope with
stick-on labels applied to front and rear panels indicating
upgraded bandwidth specication. Model number and
serial number of the oscilloscope do not change.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacic
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 0800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-07-10-14)
37 | Keysight | InniiVision 3000T X-Series Oscilloscopes - Data Sheet
This information is subject to change without notice.
© Keysight Technologies, 2014 - 2015
Published in USA, February 04, 2015
5992-0140EN
www.keysight.com
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/3000TX-Series