AESERIES POWER ENTRY MODULE EMI FILTERS V D E SPECIFICATIONS INTRODUCTIONS 1. Power module incorporates an IEC connector, a fuse holder with optional power on/off switch and voltage selector switch, plus an EMI filter all-in-one single, easy-to-install unit. 2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock prevents fuse removal with line plug inserted. 3. AE1/3/4/5: UL, CSA AE2: UL, CSA, VDE 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC MINIMUM INSERTION LOSS IN dB COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 3A 5 15 20 25 25 6A 10 20 22 35 38 10A 5 15 20 37 45 30 30 45 50 TYPE & RATED CURRENT 03AE1 06AE1 10AE1 DELTA PART NO. IEC CONNECTOR FUSE HOLDER POWER SWITCH VOLTAGE SELECTOR SW ELECTRICAL SCHEMATIC FIG. A 03AE2 06AE2 10AE2 03AE3 06AE3 03AE4 06AE4 03AE5 06AE5 SP 1 SP 1 REAR 2 FIG. A REAR 2 FIG. A FRONT 3 FIG. B FIG. A ELECTRICAL SCHEMATIC AE3, AE4 ONLY F SW L L I N E AE5 L' Cy Cx L Cy N G L O A D N' G' L N G SW L' L I N E F Cx Cy L Cy N' G' FIG. A FIG. B AE1, AE4 without power SW L1: 2.6mH (3A) L1: 0.5mH (6A) L1: 0.2mH (10A) Cx: 0.015uF Cy: 3300pF 4-2 L 110V O A 220V D 1 110V 2 110V 3 220V 110V 4 Suggested thickness of mounting panel is from 0.04 to 0.07 inch Suggest mounting cutout 27.0 1.063 0.003 R0.04Max. 1.0 2.6 0.003 66.0 2.65 67.3 29.2 I O * Optional ON/OFF switch direction 1.61 40.89 1.81 45.97 1.15 MECHANICAL CONSTRUCTION O I 2.57 65.3 AE1 (without power switch) AE2 1.059 26.9 2.65 67.3 1.15 29.2 O 1.83 46.48 115V 2.03 51.56 0.57 14.48 I AE3 AE4 (without power switch) 2.57(typ.) 1.059 26.9 29.2 1.15 65.3 1.71 43.43 2.65 67.3 1.059 26.9 2.57 65.3 AE5 4-3 UNIT: INCH mm