www.clare.com
DS-LCA182-R02 1
LCA182
RoHS
2002/95/EC e3
Pb
Single Pole OptMOS® Relay
Applications
Features
Description
Parameter Rating Units
Blocking Voltage 350 VP
Load Current 120 mA
Max RON 35 Ω
Input Control Current 0.25 mA
Pin Configuration
Switching Characteristics of
Normally Open (Form A) Devices
• Lowest Available Input Control Current (0.25mA)
• Small 6 Pin DIP Package
• Low Drive Power Requirements
(TTL/CMOS Compatible)
• No Moving Parts
• High Reliability
• Arc-Free With No Snubbing Circuits
• 3750Vrms Input/Output Isolation
• No EMI/RFI Generation
• Machine Insertable, Wave Solderable
• Surface Mount, Tape & Reel Version Available
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook,
PocketSize)
• Hook Switch
• Dial Pulsing
• Ground Start
• Ringing Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment Patient/Equipment Isolation
• Aerospace
• Industrial Controls
The LCA182 is a 1-Form-A solid state relay that
uses optically coupled MOSFET technology to
provide 3750Vrms of input to output isolation. It
features an extremely low input control current of
only 0.25mA, the lowest available in the Clare Solid
State Relay Family. The efficient MOSFET switches
and photovoltaic die use Clare's patented OptoMOS
architecture. The optically coupled output is
controlled by a highly efficient GaAlAs infrared LED.
The LCA182 can be used to replace mechanical
relays and offers the superior reliability associated
with semiconductor devices. Because they have no
moving parts, they offer faster, bounce-free switching
in a more compact surface mount or through-hole
package.
Approvals
• UL Recognized Component: File # E76270
• CSA Certified Component: Certificate # 1175739
• EN/IEC 60950 Compliant
Ordering Information
Part # Description
LCA182 6 Pin DIP (50/Tube)
LCA182S 6 Pin Surface Mount (50/Tube)
LCA182STR 6 Pin Surface Mount (1000/Reel)
CONTROL
ILOAD
10%
90%
TON
TOFF
+
+
1
3
2
4
5
6
+ Control
– Control
Do Not Use
Load
Do Not Use
Load
AC/DC Configuration
1
3
2
4
5
6
+ Control
– Control
Do Not Use
+ Load
– Load
DC Only Configuration