Counters, Panel Meters, Tachometers and Timers
Eclipse Series Panel Meter
CS Series Stroke Counter
Fusion Integrated Machine Control
Hour Meter
1.1 Totalizers
Mechanical Totalizers (Stroke) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5
Mechanical Totalizers (Revolution) . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14
Electromechanical Totalizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-29
Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41
1.2 Count Controls/Preset Counters/Totalizers
1/16 DIN Battery Powered LCD Count Control . . . . . . . . . . . . . . . . . . . V13-T1-53
1/16 DIN LCD Preset Counters with Rate and Time. . . . . . . . . . . . . . . V13-T1-55
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-57
President Series (Totalizers) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-60
President Series (Count Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-64
Ambassador Series (Totalizers). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-69
Ambassador Series (Count Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-72
PD-Q and PD-ER Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-76
1.3 Tachometers/Ratemeters
Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-80
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-82
Ambassador Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-85
1.4 Digital Panel Meters
E5-324-E Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-89
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-91
1.5 Timers/Hour Meters
Electronic Timers/Hour Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-99
Electromechanical Timers/Hour Meters . . . . . . . . . . . . . . . . . . . . . . . V13-T1-105
Hour Meter/Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-111
1.6 Flow Totalizers, Transmitters and Controls
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-114
1.7 Fusion Integrated Machine Control
Fusion Integrated Machine Control . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-119
1.8 Special Function Controls
President Position Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-124
1.9 Temperature Controls
TC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-128
1.10 Accessories and Encoders
DIN Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-132
C-Face Ring Tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-133
Magnetic Pickup Sensor and Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-134
Rotary Contactor—ES9513/ES9513RS . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-134
Measuring Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-135
Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-135
Shaft Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-136
1.11 Accessories
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-145
V13-T1-2 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l i z er s
Totalizers
Contents
Description Page
To t al i ze r s
Product Selection Guide . . . . . . . . . . . . . . . . . V13-T1-3
Mechanical
Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5
Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14
Electromechanical . . . . . . . . . . . . . . . . . . . . . . V13-T1-29
Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41
Learn
Online
Product Overview
Totalizers are used in a wide
variety of applications where
accurate totals are needed.
Typical applications include
counting the number of parts
produced, amount of material
used, or the number of
machine cycles occurring.
Totalizers are the simplest
and most common type of
counter. As an added bonus,
some models can perform
both totalizing and ratemeter
functions.
Typical Application
Parts are fed into a machine
or process, an operation is
performed, and the finished
parts exit the machine or
process. The subtract
totalizer is used to indicate
the number of parts in
process.
Application Example
Limit Switch
Limit Switch
Finished Parts
Manufacturing
Process
Raw Parts
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Product Selection Guide
Totalizers
Characteristics Typical Applications
Panel Cutout
in Inches (mm) Page
Various size ranges for different duty cycles and
environments
No power supply needed
Long life and always readable display
Winding and spooling equipment
Position display
Mechanical piece/cycle counting
Various mounting
configurations
V13-T1-5
Various price, voltage and size ranges for different
duty cycles and environments
Long life and always readable display
Coin-operated equipment
Gaming machines
Printing presses
Secondary machines (e.g. punch press)
Various mounting
configurations
V13-T1-29
Non-replaceable battery (min. eight-year life)
Compact, low cost and high efficiency
Eight-digit LCD totalizers
Manual or electrical reset
Various counting modes/inputs
Replacement for mechanical counters
Transaction counting
Parts counting
Position indication or measurement
0.870 x 1.772
(22 x 45)
V13-T1-42
Compact device with bright, LED display
Multiple functions available: count, time, rate,
multifunction, double-function
24 Vdc Power
Count, measure, time where small package and
easy-to-read display required
Position display
Motor/pulley RPM
0.870 x 1.772
(22 x 45)
V13-T1-44
Replaceable lithium battery
Eight-digit, high-visibility LCD display
Optional backlighting
Various input options available
Portable/mobile/remote flow monitoring
(e.g. sewer pumping, pesticide application)
Position display, RPM
Length measurement (e.g. carpet, cable)
1.299 x 2.677
(33 x 68)
V13-T1-46
Economical, multifunction display
Large, LED characters
AC or DC power options
Large, easy-to-read display
Position display
Motor/pulley RPM
1.772 x 3.780
(45 x 96)
V13-T1-49
Mechanical
Electromechanical
E5-024-C
E5-_24-E
Courier
E5-496-E
V13-T1-4 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Totalizers, continued
Characteristics Typical Applications
Panel Cutout
in Inches (mm) Page
Bright LED display with 14 mm characters
Simple configuration with 14-button tactile keypad
Many different versions fit almost any application
Cut-to-length machinery with batching
Parts batching/palletizing
Die press positioning control
Applications where parameter changes are required
2.667 x 5.433
(68 x 138)
V13-T1-60
Eight-digit, high-visibility, two-line LCD display
User-configurable control inputs
Highly flexible control/display
Flow control where simultaneous total and rate
display are required
Cut-to-length and other simple processes where
flexibility of inputs/outputs required
2.667 x 2.667
(68 x 68)
V13-T1-69
Combination counter consists of time meter and
adding counter in one
Without reset
High shock resistance
Magnified figures
Protection IP52 (front)
Data retention if power is lost
Long service life
UL approved
General counting
Service interval for measurement systems
(respiratory ventilators, oxygen machines,
dialysis machines)
Small appliances
UV lamps
Display panels in cars
1.988 (50.5) dia. or
DIN rail
V13-T1-111
President
Ambassador
Hour Meter/Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Mechanical Totalizers (Stroke)
Contents
Description Page
Mechanical Totalizers (Stroke)
X Series/Pushbutton Desk Tally . . . . . . . . . . . . V13-T1-6
CS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-8
H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-10
D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-12
Mechanical Totalizers (Revolution) . . . . . . . . . . . . . V13-T1-14
Electromechanical Totalizers . . . . . . . . . . . . . . . . . V13-T1-29
Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41
Mechanical Totalizers (Stroke)
Product Overview
Eaton’s mechanical totalizers
are available in a variety of
heavy-duty configurations for
applications when power is
unavailable.
Features
Variety of reset methods
available
Accurate counting without
need for power
V13-T1-6 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
X Series/Pushbutton Desk Tally
Product Description
X Series Counters
Model X Series is a dustproof
and rustproof series of
counters for light and
medium-duty work. They are
sound and durable, requiring
a minimum of driving effort,
and have been especially
designed for incorporation as
integral parts of a variety of
machines and equipment.
Pushbutton Desk Tally
Ruggedly constructed
counters with feather-touch
pushbutton operation and
maximum readability.
Specifications and
dimensions are basically the
same as the X Series
counters. Will give long and
accurate service in areas
requiring hand counting or
during hand operations.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model X
Series Stroke Counters and
Pushbutton Desk Tallies,
consider:
Number of figures
Drive
X Series Stroke Counters and Pushbutton Desk Tallies
Note
1 Reverse stroke.
No. of
Figures Drive Reset Mounting Catalog Number
Order
Number
5 LH lever Knob Base 5-X-1-1-L 40272401
4 RH lever Knob Base 4-X-1-1-R 40263401
5 RH lever Knob Base 5-X-1-1-R 40272402
5 LH lever Knob Base 5-X-1-1-L-REV 140272400
5 RH lever Knob Base 5-X-1-1-R-REV 140272403
4 Push bar Knob Base 4-X-2 21619400
4 Pushbutton Knob Base 4-X-2-A 33245400
X Series Stroke
Counter
Pushbutton Desk Tally
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-7
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
X Series
Note
1Operating stroke angles apply to forward stroke counter only. Check factory for angles of reverse stroke counter.
Description Specification
Figures 4 or 5
Speed 1000 cpm
Shaft 0.125 in (3.2 mm) diameter stainless steel
Drive Drive parts of nylon
Bearings Oil-less, maintenance free
Finish Black frame and Cycolac black cover
Stroke operation 33° minimum; 58° maximum 1
Figure size 3/16 in (4.8 mm) high, white-on-black background
Reset Knob
Model A B C D
4-X-1-1_ 1.86 (47.2) 2.76 (70.2) 0.62 (15.7) 0.89 (22.6)
5-X-1-1_ 2.16 (54.8) 3.06 (77.8) 0.81 (20.6) 0.95 (24.1)
Pre
Stroke
0.12
(3.2)
C D
0.97
(24.6)
1.20
(30.6)
1.44
(36.5)
B
A
0.44 (11.1)
0.53 (13.5) Dia. 0.093
(2.36)
0.89
(22.6)
12° ±5°
0.14
(3.6)
1.38 (35.1)
Total Stroke
58° ±5°
45° ±5°
Index Stroke
V13-T1-8 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
CS Series
Product Description
Model CS Series of small,
compact, top reading stroke
counters is designed for
use in most industrial
applications. These counters
are ruggedly built and feature
a single casting case, which
assures great rigidity and a
tight seal for working parts.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model CS
Series Stroke Counters,
consider:
Number of figures
Drive lever
CS Series Stroke Counters
Technical Data and Specifications
General Specifications
Note
1Special feature: rustproof.
No. of
Figures Drive Reset Mounting Catalog Number
Order
Number
5 RH lever Wing nut Base 5-CS-1-1-R 31062401
5 RH lever Wing nut Base 5-CS-1-1-R-RP 101464400
Description Specification
Figures 4 or 5
Speed 600 cpm
Stroke operation 37-1/2° minimum; 75° maximum
Shaft 0.25 in (6.4 mm) diameter stainless steel, rustproof
Drive Accurately machined, hardened steel parts
Bearings Oil-less, maintenance free
Figure size 11/32 in (8.7 mm) high, black-on-white background
Reset Contoured wing nut
Finish Black frame
Operating lever Cast zinc. Adjustable to any position. Furnished complete with pull spring.
CS Series Stroke
Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Dimensions
Approximate Dimensions in Inches (mm)
CS Series
Model A B C D
4-CS-1_ 3.12 (79.2) 3.50 (88.9) 4.03 (102.3) 1.87 (47.6)
5-CS-1_ 3.62 (91.9) 4.00 (101.6) 4.53 (115.0) 2.38 (60.5)
0.47
(11.9)
Dia. 0.156
4 Mtg. Holes
D0.73
(18.6)
0.42
(10.7)
0.92
(23.4)
0.50 (12.7)
A
B
C
1.19
(30.2)
1.0 0
(25.4)
Dia. 0.25
(6.35)
Stroke
37.5° Min. – 75° Max.
1.34
(34.1)
2.09
(53.1)
0.56
(14.3)
1.69 (42.9)
1.2 5
(31.8)
0.22
(5.6)
1.2 5
(31.8)
V13-T1-10 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
H Series
Product Description
Model H Series heavy-duty
counters are designed for
hard usage and long,
trouble-
free service. They are high
speed,
streamlined counters
constructed of the highest
quality materials and drive
shaft moves in oil-less
bearings. All shafts are
stainless steel. The drive
action is designed with
overstroke so counter does
not bottom, increasing life
and permitting easier
installation. The sturdy cover
is stamped steel, locked into
position on a heavy, die-cast
base of a special alloy. A
heavy steel mounting plate is
adjustable for either bottom
or back mounting. Model “H”
has earned the reputation of
being the “work horse” of
industrial counters. Wing nut
or tamper-proof reset lock
which requires a key to reset
the counter, guarding against
unauthorized resetting or
tampering.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model H
Series Stroke Counters,
consider:
Number of figures
Drive lever location
(left or right side)
Type of reset
(lock or wing nut)
H Series Stroke Counters
Notes
1 Special feature: Reverse stroke.
2 Special feature: Rustproof.
No. of
Figures Drive Reset Mounting Catalog Number
Order
Number
5 RH lever Wing nut Base 5-H-1-1-R 40205400
5 LH lever Wing nut Base 5-H-1-1-L 40205401
5 RH lever Wing nut Base 5-H-1-1-R-REV 100597400
5 LH lever Wing nut Base 5-H-1-1-L-REV 100598400
5 RH lever Wing nut Base 5-H-1-1-R-RP 240205404
5 LH lever Wing nut Base 5-H-1-1-L-RP 240205405
5 RH lever Lock reset Base 5-H-1-2-R 40206404
5 LH lever Lock reset Base 5-H-1-2-L 40206405
5 RH lever Lock reset Base 5-H-1-2-R-RP 240206400
5 RH lever Wing nut Rear 5-H-1-4-R 00507400
5 RH trip arm Wing nut Base 5-H-5-A 31049400
5 RH trip arm Wing nut Base 5-H-5-B 31049401
5 LH trip arm Wing nut Base 5-H-5-C 31049402
5 LH trip arm Wing nut Base 5-H-5-D 31049403
5 RH trip arm Lock reset Base 5-H-6-A 01533400
5 RH trip arm Lock reset Base 5-H-6-B 01534400
5 LH trip arm Lock reset Base 5-H-6-C 01535400
5 LH trip arm Lock reset Base 5-H-6-D 01536400
H Series Stroke
Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-11
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Technical Data and Specifications
Direction Location for 5H5 and 5H6
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
H Series
Description Specification
Figures 5
Speed 800 cpm
Stroke operation 37° stroke to count; 60° maximum stroke
Shaft 0.31 in (7.9 mm) diameter stainless steel, rustproof
Drive Accurately machined, hardened steel parts; Geneva drive for extra long life
Bearings Oil-less, maintenance free
Figure sizes 11/32 in (8.7 mm) high, black-on-white background
Reset Wing nut or tumbler lock reset
Finish Black frame and cover
Operating lever Adjustable to any position. Furnished complete with pull spring for attaching.
Model A B C
Five figure units 3.95 (100.4) 4.38 (111.3) 2.75 (69.9)
A
B
C
D
1.20
(30.6) C0.98
(25.0)
1.12
(28.4)
A
B
Dia. 0.31
(7.92)
2.25 (57.2)
0.91
(23.0)
1.0
(25.4)
0.75
(19.1)
0.75
(19.1)
1.8 0
(45.7)
2.76
(70.1)
Lock Reset
V13-T1-12 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
D Series
Product Description
Model D Series are medium-
duty stroke counters available
with 4, 5 or 6 figures that
have been designed for
general service on small
production machines.
Although compact, “D”
models are sturdily
constructed and thoroughly
tested for accuracy and
efficient operation.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model D
Series Stroke Counters,
consider:
Number of figures
Drive lever
D Series Stroke Counters
Technical Data and Specifications
General Specifications
No. of
Figures Drive Reset Mounting Catalog Number
Order
Number
4 RH lever Wing nut Base 4-D-1-1-R 34269401
5 RH lever Wing nut Base 5-D-1-1-R 34269402
6 RH lever Wing nut Base 6-D-1-1-R 34269403
4 LH lever Wing nut Base 4-D-1-1-L 34269405
5 LH lever Wing nut Base 5-D-1-1-L 34269406
Description Specification
Figures 4, 5 and 6
Speed 400 cpm
Shaft 0.25 in (6.4 mm) diameter stainless steel, rustproof
Drive Nylon rachet and Delrin drive plate. Right-hand drive standard; left-hand drive available
Bearings Oil-less, maintenance free
Figure size 1/4 in (6.4 mm) high, black-on-white background
Reset Wing nut
Finish Black frame and cover
Operating lever Adjustable to any position. Furnished complete with pull string
D Series Stroke
Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-13
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Dimensions
Approximate Dimensions in Inches (mm)
D Series
Model A B C
4-D-1-1_ 1.59 (40.4) 2.20 (55.9) 1.20 (30.6)
5-D-1-1_ 1.92 (48.8) 2.53 (64.3) 1.51 (38.5)
6-D-1-1_ 2.26 (57.5) 2.87 (73.0) 1.83 (46.4)
C 0.62 (15.7)
A
0.50
(12.7) B
Dia. 0.12
(3.05)
4 Mtg.
Holes
1.72
(43.6)
1.25
(31.8)
1.62 (41.3)
1.87 (47.6)
V13-T1-14 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Mechanical Totalizers (Revolution)
Contents
Description Page
Mechanical Totalizers (Stroke) . . . . . . . . . . . . . . . . V13-T1-5
Mechanical Totalizers (Revolution)
X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-15
CS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-17
D-7 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-19
D-6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-21
HDW Series . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-23
T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-25
H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-27
Electromechanical Totalizers . . . . . . . . . . . . . . . . . V13-T1-29
Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41
Mechanical Totalizers (Revolution)
Product Overview
Eaton’s mechanical totalizers
are available in a variety of
heavy-duty configurations for
applications when power is
unavailable.
Features
Variety of reset
configurations available
Accurate length
measurement for
application where
power is not available
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-15
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
X Series
Product Description
Model X Series are dust- and
rust-proof counters designed
for small, medium-duty units,
accurate, durable and require
a minimum of driving effort.
They are especially designed
for incorporation as integral
parts of a variety of equipment
that gets severe usage under
adverse climatic conditions.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model X
Series Revolution Counters,
consider:
Number of figures
Ratio
Drive shaft location
Shaft rotation direction
X Series Revolution Counters
Top View—Left-Hand Drive
Top View—Right-Hand Drive
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1 Top view—left-hand drive with clockwise shaft rotation.
2 Top view—left-hand drive with anti-clockwise shaft rotation.
3 Top view—right-hand drive with clockwise shaft rotation.
4 Top view—right-hand drive with anti-clockwise shaft rotation.
5 Special feature: 10:1 ratio.
No. of
Figures Drive Rotation Reset Mounting Catalog Number
Order
Number
4 LH Clockwise 1Knob Base 4-X-7-1-L-CL 40270406
4 LH Anti-clockwise 2Knob Base 4-X-7-1-L-AC 40270404
4 RH Clockwise 3Knob Base 4-X-7-1-R-CL 40270407
4 RH Anti-clockwise 4Knob Base 4-X-7-1-R-AC 40270405
5 RH Anti-clockwise 4Knob Base 5-X-7-1-R-AC 40275406
4 LH Clockwise 1Knob Base 4-X-7-1-L-CL 540270402
5 LH Clockwise 1Knob Base 5-X-7-1-L-CL 540275402
4 LH Anti-clockwise 2Knob Base 4-X-7-1-L-AC 540270400
5 LH Anti-clockwise 2Knob Base 5-X-7-1-L-AC 540275400
4 RH Clockwise 3Knob Base 4-X-7-1-R-CL 540270403
5 RH Clockwise 3Knob Base 5-X-7-1-R-CL 540275403
4 RH Anti-clockwise 4Knob Base 4-X-7-1-R-AC 540270401
5 RH Anti-clockwise 4Knob Base 5-X-7-1-R-AC 540275401
X Series Revolution
Counter
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
12
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
34
V13-T1-16 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
X Series
Description Specification
Figures 4 or 5
Speed 1000 cpm in 1:1 ratio;
10,000 cpm in 10:1 ratio for intermittent duty
Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter
Ratio 1:1 and 10:1 standard in 4-X-7 models
10:1 standard in 5-X-7 models
Shaft 0.125 in (3.2 mm) diameter stainless steel; standard length 0.44 in (11.1 mm)
Bearings Oil-less, maintenance free
Figure size 3/16 in (4.8 mm) high, white-on-black background
Reset Knob
Finish Black frame, Cycolac black cover
Drive Right- or left-hand drive; drive parts of Delrin
Ratio information 1:1 is one count to each revolution of drive shaft, 10:1 is ten counts to each revolution
Model ABCDE
4-X-7-1_ 1.86 (47.2) 2.76 (70.2) 0.62 (15.7) 0.19 (4.8) 0.89 (22.6)
5-X-7-1_ 2.16 (54.8) 3.06 (77.8) 0.81 (20.6) 0.25 (6.4) 0.95 (24.1)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-17
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
CS Series
Product Description
Model CS Series top reading
revolution counters are
designed for use in most
industrial applications. The
entire case is a single casting.
This provides greater rigidity,
tighter seal of working parts
and more streamlined
contour. The unit is compact,
rugged and features a flush
mounted window to assure
greater visibility.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model CS
Series Revolution
Counters, consider:
Number of figures
Ratio
Drive shaft location
Shaft rotation direction
CS Series Revolution Counters
Top View—Right-Hand Drive
Top View—Right- and Left-Hand Drive
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1 Top view—right-hand drive with clockwise shaft rotation.
2 Top view—right-hand drive with anti-clockwise shaft rotation.
3 Special feature: 10:1 ratio.
4 Top view—right- and left-hand drive with clockwise shaft rotation.
5 Special feature: 10:1 ratio, non-reset, double shaft.
6 Top view—right- and left-hand drive with anti-clockwise shaft rotation.
No. of
Figures Drive Rotation Reset Mounting Catalog Number
Order
Number
5 RH Clockwise 1Wing nut Base 5-CS-7-1-R-CL 31060409
5 RH Anti-clockwise 2Wing nut Base 5-CS-7-1-R-AC 31060411
5 LH Clockwise Wing nut Base 5-CS-7-1-L-CL 300440400
4 RH Clockwise 1Wing nut Base 4-CS-7-1-R-CL 331057401
4 RH Anti-clockwise 2Wing nut Base 4-CS-7-1-R-AC 331057403
5 RH Anti-clockwise 2Wing nut Base 5-CS-7-1-R-AC 300443400
4 RH and LH Clockwise 4None Base 4-CS-7-3-CL 531057408
4 RH and LH Anti-clockwise 6None Base 4-CS-7-3-AC 531057409
CS Series Revolution
Counter
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
1 2
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
46
V13-T1-18 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
CS Series
Description Specification
Figures 4 or 5
Speed 600 cpm in 1:1 ratio
Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter
Ratio 1:1 standard
Shaft 0.25 in (6.4 mm) diameter stainless steel; standard length 1 in (25.4 mm)
Drive Spur gear
Bearings Oil-less, maintenance free
Figure size 11/32 in (8.7 mm) high, black-on-white background
Reset Contoured wing nut
Finish Black frame
Model A B C D
4-CS-7_ 3.12 (79.2) 3.50 (88.9) 4.03 (102.3) 1.89 (47.9)
5-CS-7_ 3.62 (91.9) 4.00 (101.6) 4.53 (115.0) 2.38 (60.5)
Dia. 0.156 (3.96)
4 Mtg. Holes D
0.73
(18.6)
0.42
(10.7)
0.92 (23.4)0.50 (12.7)
A
B
C1.0 0
(25.4)
1.19
(30.2)
Dia. 0.25
(6.4)
1.69 (42.9)
1.2 5
(31.8)
0.22
(5.6)
0.56
(14.3)
1.3 4
(34.1)
2.09
(53.1)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-19
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
D-7 Series
Product Description
Model D-7 Series spur gear
end drive units are compact
counters that meet a variety
of needs. Accurate,
dependable and moderately
priced, they are especially
recommended for braiding
machines, low-speed coil
winders, wire measuring
equipment and all medium-
duty revolution applications.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model D-7
Series Revolution Counters,
consider:
Number of figures
Shaft drive
Shaft rotation direction
Reset or non-reset
D-7 Series Revolution Counters
Top View—Left-Hand Drive
Top View—Right-Hand Drive
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1 Top view—left-hand drive with clockwise shaft rotation.
2 Top view—left-hand drive with anti-clockwise shaft rotation.
3 Top view—right-hand drive with clockwise shaft rotation.
4 Top view—right-hand drive with anti-clockwise shaft rotation.
No. of
Figures Drive Rotation Reset Mounting Catalog Number
Order
Number
5 LH Clockwise 1Wing nut Base 5-D-7-1-L-CL 31127408
5 LH Anti-clockwise 2Wing nut Base 5-D-7-1-L-AC 31127405
5 RH Clockwise 3Wing nut Base 5-D-7-1-R-CL 31127431
5 RH Anti-clockwise 4Wing nut Base 5-D-7-1-R-AC 31127400
5 LH Anti-clockwise 2None Base 5-D-7-3-L-AC 31127412
5 RH Clockwise 3None Base 5-D-7-3-R-CL 31127438
D-7 Series Revolution
Counter
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
12
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
34
V13-T1-20 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
D-7 Series
Description Specification
Figures 5 standard
Speed Up to 800 cpm in 1:1 ratio
Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter
Ratio 1:1 standard
Shaft 0.31 in (7.9 mm) diameter stainless steel; 0.66 in (16.7 mm) right-hand drive,
0.63 in (15.9 mm) left-hand drive
Drive Right- or left-hand spur gear drive
Bearings Oil-less, maintenance free
Figure size 1/4 in (6.4 mm) high, black-on-white background
Finish Black frame and cover
Reset Wing nut or non-reset
1.62 (41.3)
1.7 2
(43.6)
Dia. 0.120
(3.05)
4 Mtg.
Holes
1.17
(29.8)
0.50
(12.7)
Dia. 0.31
(7.9)
0.12
(3.2)
0.75
(19.0)
1.51
(38.5)
0.50
(12.7) 2.53 (64.3)
1.92 (48.8)
0.78
(19.8)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-21
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
D-6 Series
Product Description
Model D-6 right-angle worm
drive counters are ruggedly
designed for high speeds on
light-duty applications. Small
“D” counters are easily
adapted as accessory
equipment on machinery
where right-angle drive is
desired to permit full view
reading of the counter.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model D-6
Series Revolution Counters,
consider:
Shaft rotation direction
D-6 Series Revolution Counters
Top View of Counter
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1 Top view of counter—anti-clockwise shaft rotation.
2 Top view of counter—clockwise shaft rotation.
3 Special feature: Measuring wheels and brackets available for lineal measurement in feet.
4 Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths.
5 Special feature: Measuring wheels and brackets available for lineal measurement in yards.
No. of
Figures Drive Rotation Reset Mounting Catalog Number
Order
Number
5 Front and rear Anti-clockwise 1Wing nut Base 5-D-6-1-AC 31052401
6 Front and rear Anti-clockwise 1Wing nut Base 6-D-6-1-AC 31052402
5 Front and rear Clockwise 2Wing nut Base 5-D-6-1-CL 31052404
6 Front and rear Clockwise 2Wing nut Base 6-D-6-1-CL 31052405
5 Front and rear Anti-clockwise 1Wing nut Base 5-D-8-1-AC 340187401
5 Front and rear Clockwise 2Wing nut Base 5-D-8-1-CL 340187417
6 Front and rear Clockwise 2Wing nut Base 6-D-8-1-CL 340187418
5 Front and rear Clockwise 2Wing nut Base 5-D-9-1-CL 440187404
5 Front and rear Anti-clockwise 1Wing nut Base 5-D-9-1-AC 440187410
5 Front and rear Clockwise 2Wing nut Base 5-D-90-1-CL 540187414
5 Front and rear Anti-clockwise 1Wing nut Base 5-D-90-1-AC 540187408
D-6 Series Revolution
Counter
Clockwise Shaft Rotation
2
Anti-Clockwise Shaft Rotation
1
V13-T1-22 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
D-6 Series
Note
1A = 1.85 in (46.9 mm) for 6 figures and 1.53 in (38.9 mm) for 5 figures.
Description Specification
Figures 5 or 6
Speed Up to 1500 cpm in 1:1 ratio
Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter
Ratio 1:1 standard
Shaft 0.31 in (7.9 mm) diameter stainless steel; 1.25 in (31.8 mm) length standard
Drive Worm drive
Bearings Oil-less, maintenance free
Figure size 1/4 in (6.4 mm) high, black-on-white background
Finish Black frame and cover
Reset Wing nut
Reading
Line
0.50 (12.7) 0.66 (16.7)
3.19 (81.0)
2.81 (71.4)
A0.84
(21.4)
0.34
(8.7)
0.12
(3.0)
2.0
(50.8)
0.75
(19.0)
Dia. 0.31
(7.93)
1.16
(29.4)
1.2 3
(31.4)
3.62 (92.1)
2.00 (50.8)
1.6 2
(41.3)
Dia. 0.144
(3.66)
4 Mtg.
Holes
1
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-23
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
HDW Series
Product Description
Model HDW Series are high
speed, end drive revolution
counters that have the
rugged features of all “H”
counters, with the addition of
double worm drive that
produces speeds up to 2000
cpm. Lightweight precision
molded wheels reduce
centrifugal force and
eliminate slipping. They are
particularly recommended for
quick starting and stopping
machines, such as coil
winders and wire measuring
or reeling equipment and on
applications where
continuous high speed
measuring is required.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model
HDW Series Revolution
Counters, consider:
Shaft drive
Shaft rotation direction
HDW Series Revolution Counters
Top View—Right-Hand Drive
Top View—Left-Hand Drive
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1 Mounting plate is adjustable for base or back mounting.
2 Top view—right-hand drive with clockwise shaft rotation.
3 Top view—right-hand drive with anti-clockwise shaft rotation.
4 Top view—left-hand drive with clockwise shaft rotation.
5 Top view—left-hand drive with anti-clockwise shaft rotation.
No. of
Figures Drive Rotation Reset Mounting 1Catalog Number
Order
Number
5 RH Clockwise 2Wing nut Base 5-HDW-7-1-R-CL 31050400
5RHAnti-
clockwise
3Wing nut Base 5-HDW-7-1-R-AC 31050401
5 LH Clockwise 4Wing nut Base 5-HDW-7-1-L-CL 31050402
5LHAnti-
clockwise
5Wing nut Base 5-HDW-7-1-L-AC 31050403
HDW Series
Revolution Counter
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
23
Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation
45
V13-T1-24 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
HDW Series
Description Specification
Figures 5
Speed Up to 2000 cpm
Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter
Ratio 1:1 only
Shaft 0.31 in (7.9 mm) diameter stainless steel; standard length 2 in (50.8 mm)
Drive Right- or left-hand drive
Bearings Oil-less, maintenance free
Figure size 11/16 in (17.5 mm) high, white-on-black background
Reset Wing nut or tumbler lock reset
Finish Black frame and cover
0.96 (24.4)
0.90
(22.9)
1.8 0
(45.7)
2.76
(70.1)
Dia. 0.312
(7.9)
2.00
(50.8)
0.98
(25.0)2.75
(69.9)
Dia. 0.22 (5.59)
4 Mtg. Holes
0.75
(19.1)
4.51
(100.3)
4.94
(111.3)
0.34
(8.5)
1.12
(28.4)
2.25
(57.2)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-25
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
T Series
Product Description
Model T Series worm drive
revolution counters are
sturdy, high speed
instruments used on many
heavy machines, engines or
motors. Variety of drive
permits direct connection.
Suitable for panel mounting.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model T
Series Revolution Counters,
consider:
Shaft rotation direction
T Series Revolution Counters
Top View of Counter
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1 Top view of counter—clockwise shaft rotation.
2 Top view of counter—anti-clockwise shaft rotation.
3 Special feature: Measuring wheels and brackets available for lineal measurement in feet.
4 Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths.
5 Special feature: Measuring wheels and brackets available for lineal measurement in yards.
No. of
Figures Drive Rotation Reset Mounting Catalog Number
Order
Number
5 Top and bottom Anti-clockwise 2Wing nut Back 5-T-6-1-AC 40342401
T Series Revolution
Counter
Clockwise Shaft Rotation
1
Anti-Clockwise Shaft Rotation
2
V13-T1-26 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
T Series
Description Specification
Figures 5 standard
Speed 1500 cpm in 1:1 ratio
Rotation direction Clockwise or anti-clockwise determined top looking down
Ratio 1:1 standard
Shaft 0.31 in (7.9 mm) diameter stainless steel; standard extends 2 in (50.8 mm) top and bottom
Drive Hobbed steel and bronze worm gearing; subtracts when reversed
Bearings Oil-less, maintenance free
Figure size 11/32 in (8.7 mm) high, black-on-white background
Reset Left-hand wing nut standard
Finish Black frame and face plate
1/4-20 UNC-2B
4 Mtg. Holes
5.00 (127.0)
0.75
(19.1)
0.47
(11.9)
2.97 (75.4)
1.36 (34.5)
2.38
(60.5)
0.24
(6.2)
1.4 1
(35.7)
1.3 8
(35.1)
0.62
(15.9)
1.8 7
(47.6)
0.25
(6.4)
2.19
(55.6)
4.50 (114.2)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-27
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
H Series
Product Description
Model H Series are heavy-
duty, end drive revolution
counters designed for
industrial use; suitable for
speeds up to 800 cpm. They
are available with either right-
or left-hand drive, and with
wing nut reset.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model
H Series Revolution
Counters, consider:
Drive shaft location
Shaft rotation direction
H Series Revolution Counters
For 5-H-8 and 5-H-9 Series
Counters, drive shaft extends
from both sides of the
counter. Specifying RH or LH
drive will determine the
location of the reset (i.e. LH
drive will have reset on the
right-hand side of the
counter, and RH drive will
have reset on left-hand side
of the counter).
Top View—LH Drive Top View—RH Drive Top View—RH and LH Drive
Notes
When shaft is turned in the reverse direction of rotation, the counter will subtract.
1Mounting plate is adjustable for base or back mounting.
2Top view—left-hand drive with clockwise shaft rotation.
3Top view—left-hand drive with anti-clockwise shaft rotation.
4Top view—right-hand drive with clockwise shaft rotation.
5Top view—left-hand drive with anti-clockwise shaft rotation.
6Top view—right-hand and left hand drive with clockwise shaft rotation.
7Special feature: Measuring wheels and brackets available for lineal measurement in feet.
8Top view—right-hand and left hand drive with anti-clockwise shaft rotation.
9Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths.
jSpecial feature: Measuring wheels and brackets available for lineal measurement in yards.
No. of
Figures Drive Rotation Reset Mounting 1Ratio Catalog Number
Order
Number
5 LH Clockwise 2Wing nut Base 1.1 5-H-7-1-L-CL 00509400
5 LH Anti-clockwise 3Wing nut Base 1.1 5-H-7-1-L-AC 00510400
5 RH Clockwise 4Wing nut Base 1.1 5-H-7-1-R-CL 00513400
5 RH Anti-clockwise 5Wing nut Base 1.1 5-H-7-1-R-AC 00514400
5 LH Clockwise 6Wing nut Base 3.2 5-H-8-1-L-CL 700601400
5 LH Anti-clockwise 8Wing nut Base 3.2 5-H-8-1-L-AC 700602400
5 RH Clockwise 6Wing nut Base 3.2 5-H-8-1-R-CL 700605400
5 RH Anti-clockwise 8Wing nut Base 3.2 5-H-8-1-R-AC 700606400
5 LH Clockwise 6Wing nut Base 1.2 5-H-9-1-L-CL 900619400
5 LH Anti-clockwise 8Wing nut Base 1.2 5-H-9-1-L-AC 900620400
5 RH Clockwise 6Wing nut Base 1.2 5-H-9-1-R-CL 900617400
5 RH Anti-clockwise 8Wing nut Base 1.2 5-H-9-1-R-AC 900618400
5 LH Clockwise 6Wing nut Base 1.2 5-H-9-0-1-L-CL j00611400
5 RH Clockwise 6Wing nut Base 1.2 5-H-9-0-1-R-CL j00609400
5 RH Anti-clockwise 8Wing nut Base 1.2 5-H-9-0-1-R-AC j00610400
H Series Revolution
Counter
Clockwise Shaft Rotation
2
Anti-Clockwise Shaft Rotation
3
Clockwise Shaft Rotation
4
Anti-Clockwise Shaft Rotation
5
Clockwise Shaft Rotation
6
Anti-Clockwise Shaft Rotation
8
V13-T1-28 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
H Series
Description Specification
Figures 5
Speed Up to 800 cpm
Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter
Shaft 0.31 in (7.9 mm) diameter stainless steel; standard length 2 in (50.8 mm)
Drive Right- or left-hand drive
Bearings Oil-less, maintenance free
Figure size 11/32 in (8.7 mm) high, white-on-black background
Reset Wing nut
Finish Black frame and cover
Mounting bracket available Order number 01465400
4.38 (111.3)
0.34
(8.5)
1.12
(28.4)
2.25 (57.2)
3.95
(100.4)
2.75
(69.9) 0.98
(25.0)
Dia. 0.312
(7.92)
1.8 0
(45.7)
2.76
(70.1)
0.91
(23.0)
2.00
(50.8)
Dia. 0.220
4 Mtg. Holes
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-29
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Electromechanical Totalizers
Contents
Description Page
Mechanical Totalizers
Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5
Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14
Electromechanical Totalizers
Micro Display Counter . . . . . . . . . . . . . . . . . . . V13-T1-30
SE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-32
MF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-34
RMF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-36
ME Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-38
Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41
Electromechanical Totalizers
Product Overview
Eaton’s electromechanical
counters provide accurate
counting from a variety of
electrical signals and a display
that is always readable, even
when power is not present.
Features
Available with reset and
without
Always readable display
Variety of mounting
options
Standards and Certifications
UL certifications on some
products (see individual
product pages for details)
V13-T1-30 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Micro Display Counter
Product Description
Eaton’s micro display counter
is perfect for 12 Vdc
applications where small size
is important.
Features
Seven-digit micro adding
counter
High shock resistance
Low power consumption;
suitable for battery
consumption
Small dimensions
Large optical figures
Different viewing
possibilities
Flush mount with
integrated spring clip
Protection IP65
Stores value also at power
failure
Long service life
Standards and Certifications
cRU®us certified
CE marked
Product Selection
Micro Display Counter
Technical Data and Specifications
General Specifications
Description Catalog Number
Micro display counter 7-Y-3013PM-401
Description Specification
Electrical connections Built-in counter, flying leads, AWG 22, approx. 5.9 in (150 mm)
Power consumption At 68°F (20°C) and nominal voltage
At 25 lmp/s: approx. 250 mW
Rated voltage 12 Vdc ±10%
Counting frequency 25 lmp/s
Pulse duration Min. 20 ms
Pulse interval Min. 20 ms
Cycle duration factor 100%
Number of digits 7
Counting system Adding
Figure size 0.05 x 0.16 in (1.2 x 4 mm) high optical
Color of figures White-on-black
Reset No reset
Ambient temperature 14° to 140°F (–10° to 60°C)
Mounting position Any
Operating Life >50 x 106 pulses
Protection IP65 (only front side)
Housing Clear plastic
Weight 0.53–0.71 oz (15–18g)
Micro Display Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-31
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Dimensions
Approximate Dimensions in Inches (mm)
Micro Display Counter
1.26 (32)
0.59 (15)
0.59
(15)
1.29
(32.7)
0.51 x 1.18
(13 x 29.9)
0.08 (2)
0.04 (1.1)
0.12 (3)
Max.
Rmax 0.02 (0.5)
0.51 +0.02
(13 +0.5)
1.18 +0.01
(30 +0.3)
V13-T1-32 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
SE Series
Product Description
Compact electromechanical
counters.
Features
Low-cost
electromechanical counter
Multiple voltage ranges for
almost any application
Compact with various
mounting options
Wire leads for electrical
connections
Standards and Certifications
UL recognized
Product Selection
SE Series Electromechanical Counters
Description Catalog Number
Order
Number
Six-Digit Electric Counter
Bottom mount sub-miniature 12 Vdc 6-Y-41610-401-SE 41610401
Bottom mount sub-miniature 24 Vdc 6-Y-41610-402-SE 41610402
Bottom mount sub-miniature 120 Vac 6-Y-41610-406-SE 41610406
Bottom mount sub-miniature 240 Vac 6-Y-41610-407-SE 41610407
Base mount sub-miniature 12 Vdc 6-Y-41611-401-SE 41611401
Base mount sub-miniature 24 Vdc 6-Y-41611-402-SE 41611402
Base mount sub-miniature 120 Vac 6-Y-41611-406-SE 41611406
Base mount sub-miniature 240 Vac 6-Y-41611-407-SE 41611407
Panel mount sub-miniature 12 Vdc 6-Y-41613-401-SE 41613401
Panel mount sub-miniature 24 Vdc 6-Y-41613-402-SE 41613402
Panel mount sub-miniature 120 Vac 6-Y-41613-406-SE 41613406
Panel mount sub-miniature 240 Vac 6-Y-41613-407-SE 41613407
Special base mount sub-miniature 12 Vdc 6-Y-41622-401-SE 41622401
Special base mount sub-miniature 24 Vdc 6-Y-41622-402-SE; 41622402
Special base mount sub-miniature 120 Vac 6-Y-41622-406-SE 41622406
Special top mount sub-miniature 12 Vdc 6-Y-41623-401-SE 41623401
Special top mount sub-miniature 24 Vdc 6-Y-41623-402-SE 41623402
Special top mount sub-miniature 120 Vac 6-Y-41623-406-SE 41623406
Special top mount sub-miniature 240 Vac 6-Y-41623-407-SE 41623407
Snap-in mount sub-miniature 12 Vdc 6-Y-42613-401-SE 42613401
Snap-in mount sub-miniature 24 Vdc 6-Y-42613-402-SE 42613402
Snap-in mount sub-miniature 120 Vac 6-Y-42613-406-SE 42613406
Snap-in mount sub-miniature 240 Vac 6-Y-42613-407-SE 42613407
SE Series Counter—
Electromechanical
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-33
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
SE Series
Bottom Mount
Special Base Mount
Base Mount
Special Top Mount
Top Mount
Snap Mount
Panel Mount
Description Specification
Figures 6
Count speed 600 cpm
Figure size 5/32 in (4.0 mm)
Reset None
Mounting Base, bottom, top, panel or snap-in
Finish Black, self-extinguishing plastic
Power requirements DC: 1.5W, AC: 5.0V
1.01
(25.7)
1.0 0
(25.4)
1.31
(33.2)
2.16
(54.9)
0.63
(15.9)
10
(254)
(2) #4-40 UNC 28
10
(254)
1.97
(50)
1.50
(38.1)
1.75
(44.5)
1.13
(28.6)
2.34
(59.5)
2.16
(54.9)
0.19
(4.7)
0.14 (3.6) Dia.
10
(254)
0.69
(17.4)
1.0 0
(25.4)
1.88
(47.6) (4) 0.13 (3.2) Dia.
Mounting Holes
2.19
(55.5)
2.16
(54.9)
0.19
(4.7)
1.0 0
(25.4)
(2) #4-40
Mounting
Holes 1.06
(26.9)
1.31
(33.2)
2.16
(54.9)
10
(254)
0.88
(22.2)
(2) #4-40
Mounting
Holes 1.0
(25.4)
1.31
(33.2)
2.16
(54.9)
10
(254)
1.81
(46.0)
1.44
(36.5)
2.16
(54.9)
10
(254)
Panel Cutout
1.70 x 1.33
(43.2 x 33.8)
10
(254)
1.80
(45.7)
1.52
(38.7)
Mounting Holes
for #6 FHMS
2.16
(54.9)
Panel Cutout
1.43 x 1.13
(36.3 x 28.6)
V13-T1-34 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
MF Series
Product Description
Model MF Series are shaded
pole electric
counters with
straight AC operation and
feature a non-rectified,
shaded pole coil designed to
withstand transient, high
voltage spikes. This feature,
combined with a simplified,
hinged escapement drive,
also eliminates the possibility
of miscounts and greatly
adds to the life of the
counter. Tallies at speeds
up to 750 cpm.
Product Selection
MF Series Electric Counters
Technical Data and Specifications
General Specifications
Note
1UL Recognized.
No. of
Figures Voltage Reset Mounting Catalog Number
Order
Number
7 120 Vac Knob Base 7-Y-1-MF-120A 132650400
6 120 Vac Knob Base 6-Y-1-MF-120A 132651400
7 120 Vac Knob Panel 7-Y-1-MF-PM-120A 132652400
7 120 Vac Non-reset Panel 7-Y-13-MF-PM-120A 132652402
6 120 Vac Knob Panel 6-Y-1-MF-PM-120A 132653400
6 120 Vac Non-reset Panel 6-Y-13-MF-PM-120A 132653405
6 120 Vac Keylock reset Panel 6-Y-12-MF-PM-120A 132654400
6 24 Vac Keylock reset Panel 6-Y-12-MF-PM-24A 32654403
7 120 Vac Keylock reset Panel 7-Y-12-MF-PM-120A 132655400
6 120 Vac Non-reset Base 6-Y-13-MF-120A 132658400
Description Specification
Figures 6 or 7
Speed Up to 750 cpm
Figure size 3/16 in (4.8 mm) high, white-on-black background
Reset Knob, key or non-reset
Mounting Base or panel mount
Finish Black frame and side covers
Electrical connections Two-wire leads, 9 in (229 mm) long, AWG 22 (0.34 mm2), stripped 0.38 in (9.5 mm)
Power requirements 12 watts
Coils Various AC voltages and frequencies can be supplied on special order.
Count coils are designed for continuous duty at rated voltage.
MF Series Electric
Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-35
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Dimensions
Approximate Dimensions in Inches (mm)
MF Series
Panel Mounted
Base Mounted
Panel Mounted with Tumbler Lock
3.51 x 1.44 (89.3 x 36.5) Panel Opening
2.09
(53.1)
0.25
(6.3)
3.68 (93.5)
2.56 (65.0)
0.56
(14.2)
0.62
(15.7)
2.56
(65.0)
Panel
0.30 (7.5)
0.19 (4.8)
AB
4.00 (101.6)
4.37 (111.1)
Dia. 0.15 (3.81)
4 Mtg. Holes
#6-32 Top Mount
Models Only
4 Mtg. Holes
1.25
(31.8)
1.62
(41.3)
0.19
(4.8)
E F
1.37
(34.9)
0.87
(22.2)
Dia. 0.14 (3.6)
4 Mtg. Holes
0.28
(7.1)
2.56
(65.0)
0.62
(15.7)
3.16 (80.2) 0.41
(10.3)
2.09
(53.1)
0.25
(6.3)
3.68 (93.5)
3.31 (84.1)
2.56 (65.0) 0.56
(14.2)
4.62 x 1.44 (117.3 x 36.5) Panel Opening
5.50 (139.7)
5.12 (130.2)
CD
0.12
(3.0)
0.19
(4.8)
2.12
(54.0)
1.75
(44.5)
0.97 (24.6)
Dia. 0.15 (3.81)
4 Mtg. Holes
0.16
(4.0)
1.2 5
(31.8) 0.09
(2.4)
0.06
(1.6)
3.68 (93.5)
Panel
2.56
(65.0)
Model ABCDE F
Six figures 1.73 (44.0) 1.58 (40.0) 1.73 (43.9) 2.80 (71.1) 1.73 (44.0) 1.12 (28.6)
Seven figures 2.02 (51.4) 1.29 (32.7) 2.03 (51.6) 2.50 (63.5) 2.02 (51.4) 0.84 (21.2)
V13-T1-36 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
RMF Series
Product Description
Model RMF Series of electric
counters are designed to give
accurate counts through a
wide range of speeds up to
1000 cpm. It features a
strong, silent, fast operating
DC electromagnetic drive
with a compact, dependable
built-in higher capacity
rectifier for AC operation. The
counter has a minimum of
moving parts that never need
lubrication under normal
operating conditions.
Compact and rigid, it
continues to operate
dependably even when
subject to severe shock and
vibrations. Entirely enclosed
to prevent damage from
moisture and dust. Available
in 6 or 7 figures.
Product Selection
When Ordering Specify
To determine a model
number from the Product
Selection table for Model
RMF Series Electronic
Counters, consider:
Number of figures
Volt age
Type of reset
Type of mounting
RMF Series Electromechanical Counters
Note
1 UL recognized.
No. of
Figures Voltage Reset Mounting Catalog Number
Order
Number
6 24 Vdc Knob Panel 6-Y-1-RMF-PM-24D 31013400
7 24 Vdc Knob Panel 7-Y-1-RMF-PM-24D 31019400
7 115 Vac Knob Base 7-Y-1-RMF-115A 131025400
7 115 Vac Non-reset Base 7-Y-13-RMF-115A 131026400
7 115 Vac Knob Panel 7-Y-1-RMF-PM-115A 131026401
7 115 Vac Non-reset Panel 7-Y-13-RMF-PM-115A 131026402
6 115 Vac Non-reset Base 6-Y-13-RMF-115A 131039400
6 230 Vac Knob Panel 6-Y-1-RMF-PM-230A 31066413
6 115 Vac Knob Panel 6-Y-1-RMF-PM-115A 131066416
6 115 Vac Keylock reset Panel 6-Y-12-RMF-PM-115A 131083403
6 230 Vac Keylock reset Panel 6-Y-12-RMF-PM-230A 31083405
7 115 Vac Keylock reset Panel 7-Y-12-RMF-PM-115A 131083409
6 24 Vac Keylock reset Panel 6-Y-12-RMF-PM-24A 31083411
6 24 Vdc Keylock reset Panel 6-Y-12-RMF-PM-24D 31083415
7 24 Vdc Keylock reset Panel 7-Y-12-RMF-PM-24D 31083421
7 230 Vac Keylock reset Panel 7-Y-12-RMF-PM-230A 31083427
6 24 Vac Knob Base 6-Y-1-RMF-24A 31155400
6 240 Vac Knob Base 6-Y-1-RMF-240A 31155401
6 115 Vac Knob Base 6-Y-1-RMF-115A 131155402
6 115 Vac Non-reset Panel 6-Y-13-RMF-PM-115A 131155405
7 24 Vdc Non-reset Panel 7-Y-13-RMF-PM-24D 33183400
RMF Series Counter—
Electromechanical
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-37
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Technical Data and Specifications
General Specifications
Dimensions
Refer to table and illustrations
on Page V13-T1-35 for
information.
Description Specification
Figures 6 or 7
Speed Up to 1000 cpm
Figure size 3/16 in (4.8 mm) high, white-on-black background
Reset Knob, key or non-reset
Mounting Base or panel mount
Finish Black frame and side covers
Electrical connections Two-wire leads, 9 in (229 mm) long, AWG 22 (0.34 mm2), stripped 0.38 in (9.5 mm)
Power requirements 7 watts
Coils Various voltages and frequencies can be supplied on special order.
Count coils are designed for continuous duty at rated voltage
V13-T1-38 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
ME Series
Product Description
Small in size and price, but
large in design versatility and
model variety is the ME
Series of miniature electric
counters. Models in most
popular AC or DC voltages
operate on as little as 3
watts, with the non-reset
models measuring only 1 x
1.593 x 2.187 in (25.4 x 40.5 x
55.5 mm) and weighing just
three ounces (85 grams).
Available in 4, 6 or 7 figures,
the counters feature stainless
steel self-lubricating shafts,
nylatron pinions and a
synchronous electromagnetic
drive to assure accurate,
reliable, long life operation.
Designed for mounting
flexibility and aesthetic
attractiveness, the miniature
electric counters are available
with three types of mounting
and a glare retarding finish
Delrin, with crisp easy-to-read
numerals set close to a
tamper-proof sealed figure
window.
Standards and Certifications
UL recognized
Product Selection
When Ordering Specify
When ordering ME Series
Miniature Electric Counters,
specify catalog numbers
according to the features
selected.
Bottom Mount Wire Leads Base Mount Wire Leads Panel Mount Wire Leads
ME Series Miniature Electric Counters
No. of
Figures Voltage Reset Mounting Catalog Number
Order
Number
4 12 Vdc Pushbutton Bottom 4-Y-41312-401-MEQ 41312401
4 24 Vdc Pushbutton Bottom 4-Y-41312-402-MEQ 41312402
4 120 Vac Pushbutton Bottom 4-Y-41312-406-MEQ 41312406
4 24 Vdc Pushbutton Base 4-Y-41313-402-MEQ 41313402
4 120 Vac Pushbutton Base 4-Y-41313-406-MEQ 41313406
4 240 Vac Pushbutton Base 4-Y-41313-407-MEQ 41313407
4 12 Vdc Pushbutton Panel 4-Y-41314-401-MEQ 41314401
4 24 Vdc Pushbutton Panel 4-Y-41314-402-MEQ 41314402
4 120 Vac Pushbutton Panel 4-Y-41314-406-MEQ 41314406
4 240 Vac Pushbutton Panel 4-Y-41314-407-MEQ 41314407
ME Series Miniature
Electric Counter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-39
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
ME Series Miniature Electric Counters, continued
Technical Data and Specifications
General Specifications
No. of
Figures Voltage Reset Mounting Catalog Number
Order
Number
6 24 Vdc Non-reset Bottom 6-Y-41119-402-ME 41119402
6 120 Vac Non-reset Bottom 6-Y-41119-406-ME 41119406
6 12 Vdc Non-reset Base 6-Y-41345-401-ME 41345401
6 24 Vdc Non-reset Base 6-Y-41345-402-ME 41345402
6 120 Vac Non-reset Base 6-Y-41345-406-ME 41345406
6 240 Vac Non-reset Base 6-Y-41345-407-ME 41345407
6 12 Vdc Non-reset Panel 6-Y-41346-401-ME 41346401
6 24 Vdc Non-reset Panel 6-Y-41346-402-ME 41346402
6 120 Vac Non-reset Panel 6-Y-41346-406-ME 41346406
6 240 Vac Non-reset Panel 6-Y-41346-407-ME 41346407
7 12 Vdc Non-reset Bottom 7-Y-41238-401-ME 41238401
7 24 Vdc Non-reset Bottom 7-Y-41238-402-ME 41238402
7 120 Vac Non-reset Bottom 7-Y-41238-406-ME 41238406
7 12 Vdc Non-reset Base 7-Y-41337-401-ME 41337401
7 24 Vdc Non-reset Base 7-Y-41337-402-ME 41337402
7 120 Vac Non-reset Base 7-Y-41337-406-ME 41337406
7 12 Vdc Non-reset Panel 7-Y-41349-401-ME 41349401
7 24 Vdc Non-reset Panel 7-Y-41349-402-ME 41349402
7 120 Vac Non-reset Panel 7-Y-41349-406-ME 41349406
7 240 Vac Non-reset Panel 7-Y-41349-407-ME 41349407
Description Specification
Figures 4, 6 and 7
Speed Up to 1000 cpm
Figure size 3/16 in (4.8 mm) high
Reset Pushbutton and non-reset
Reset force Pushbutton models only, 20 oz. (568 grams) maximum
Mounting Base, bottom, panel
Finish Black self-extinguishing plastic
Electrical connections Wire leads, 10 in (254 mm) long, AWG 20, stripped 3/8 in (9.5 mm), and pin terminals
Power requirements 3W
Coils Count coils are designed for continuous duty at rated voltage
ME Series Miniature
Electric Counter
V13-T1-40 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Dimensions
Approximate Dimensions in Inches (mm)
ME Series Counters
Panel Mounted
Base Mounted
ME Series Counters
Bottom Mounted
Bottom Mounted
Recommended Panel Mount Cut-Outs
4 Figure Pushbutton Reset Counters 6 and 7 Figure Non-Reset Counters
Dimension Inches (mm) Dimension Inches (mm)
A 1.00 (25.4) A 1.00 (25.4)
B 1.60 (40.6) B 1.60 (40.6)
C 2.64 (67.1) C 2.38 (60.5)
D 2.19 (55.6) D 2.19 (55.6)
E 1.80 (45.7) E 1.80 (45.7)
F 1.80 (45.7) F 1.80 (45.7)
G 1.40 (35.6) G 1.40 (35.6)
H 0.69 (17.5) H 0.69 (17.5)
J 1.88 (47.8) J 1.88 (47.8)
K 0.50 (12.7) K 0.50 (12.7)
L 0.49 (12.4) L 0.49 (12.4)
M 0.94 (23.9) M 0.94 (23.9)
N 2.45 (62.2) N 2.19 (55.6)
P 2.45 (62.2) P 2.19 (55.6)
Q 0.45 (11.4) Q 0.45 (11.4)
R 0.63 (16.0) R 0.63 (16.0)
S 0.19 (4.8) S 0.19 (4.8)
T 0.68 (17.3) T 0.88 (22.4)
4 Figure Counters 6 and 7 Figure Counters
Pushbutton Reset Non-Reset
1.72 x 1.11 (43.7 x 28.2) 1.72 x 1.11 (43.7 x 28.2)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-41
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Electronic Totalizers
Contents
Description Page
Mechanical Totalizers
Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5
Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14
Electromechanical Totalizers . . . . . . . . . . . . . . . . . V13-T1-29
Electronic Totalizers
1/32 DIN LCD Totalizers . . . . . . . . . . . . . . . . . . V13-T1-42
1/32 DIN LED Multifunction
Totalizer/Timer/Ratemeter . . . . . . . . . . . . . . . V13-T1-44
Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-46
1/8 DIN LED Multifunction
Totalizer/Timer/Ratemeter . . . . . . . . . . . . . . . V13-T1-49
Electronic Totalizers
Product Overview
Eaton’s electric totalizers
provide a flexible and
accurate method of
displaying count and
measurement data in an
easily readable format.
Features
LED and LCD readouts
Variety of sizes and
packages
Programmable inputs and
displays available
Standards and Certifications
Most products are UL
certified (see individual
product pages for details)
CE
V13-T1-42 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
1/32 DIN LCD Totalizers
Product Description
Compact battery powered
totalizers where AC power is
unavailable.
Features
Low price and high
efficiency
Large eight-digit LCD
display, height of the
figures 0.31 in (8 mm)
Various counting modes
like up/down differential
available
High voltage input for
10–260 Vac/Vdc voltage
pulses
IP65
Screw terminals, RM
5mm
Lifetime of the battery
approximately eight years
Locking of the reset key
Operating temperature
1 to 140°F (–10° to 60°C)
All version of positive or
negative counting edge
Filter function for bounce-
free counting with
mechanical contacts
Standards and Certifications
UL recognized
CE marked
Product Selection
1/32 DIN LCD Totalizers
Technical Data and Specifications
1/32 DIN LCD Totalizers
Description Catalog Number
Eight-Digit LCD Totalizer, Battery Power
4–30 Vdc powered, NPN/PNP 0.94 x 1.89 in (24 x 48 mm) E5-024-C0400
10–120V input AC/DC powered, NPN only 0.94 x 1.89 in (24 x 48 mm) E5-024-C0408
Count up/down 4–30 Vdc powered, NPN only, 0.94 x 1.89 in (24 x 48 mm) E5-024-C0410
Description Specification
Power supply Non-replaceable lithium battery (lifetime approximately eight years at 68°F (20°C)
Display LCD, eight-digits
Figure size 0.31 in (8 mm) high
Mode Adding or subtracting (selectable), counting direction, differential counting or phase
discriminator single or dual evaluation (selectable)
Display range –9999999 to 99999999, with overflow display
Reset Manual and electrical
Interference emissions EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions)
Housing Dark gray RAL 7021
Operating temperature 14° to 131°F (–10° to 55°C)
Ambient temperature 14° to 140°F (–10° to 60°C)
Storage temperature –4° to 158°F (–20° to 70°C)
Protection IP65 (from front)
Weight Approx. 1.76 oz (50g)
E5-024-C04_
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-43
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
1/32 DIN LCD Totalizers, continued
Dimensions
Approximate Dimensions in Inches (mm)
1/32 DIN LCD Totalizers
Description Specification
Counting inputs:
Counting input of the DC version Max. 30 Vdc
Slow counting input Max. 30 Hz (NPN)
Fast counting input Max. 12 kHz (PNP)
Switching level NPN: Low 0–0.7V, High 3–30 Vdc
PNP: Low 0–0.7V, High 3–30 Vdc
Counting Input of the high voltage versions 10–260 Vac/Vdc
Counting input Optocoupler input, max. 30 Hz
Min. pulse time 16 ms
Switching level Low: 0–2 Vac/Vdc
High: 10–260 Vac/Vdc
Counting direction switching (only DC versions) Contact input, open collector NPN (switching at 0 Vdc)
Switching level, NPN—Low, 0–0.7V, High 3–5 Vdc
Reset input (only DC and high voltage)—
Minimum pulse time DC: 50 ms; high voltage: 16 ms
Contact input NPN Low: 0–0.7V
High: 3–30 Vdc
High voltage input 10–260 Vac/Vdc
Electrical reset key locking (for DC and AC) Contact input, open collector NPN (switching at 0V)
Switching level, NPN—Low, 0–0.7V, High 3–5 Vdc
1.77
+ 0.024
(45
+ 0.6
)
1.7 7
+ 0.012
(22.2
+0.3
)
1.89 (48)
MAX. 1.89 (19.3)
0.11 (2.8)
0.12 (3)
1.88 (47.7)
0.87 x 1.77
(22 x 45)
0.94
(24)
V13-T1-44 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter
Product Description
Compact LED display for a
variety of input signals.
Features
Display counter adding and
subtracting
Position display
Frequency counter/
ratemeter
Timer
Display range: –199.999 to
999.999 with zero blanking
Screw terminal
Locking SET-key
Standards and Certifications
UL recognized
CE marked
Product Selection
1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter
Technical Data and Specifications
General Specifications
Description Catalog Number
LED Single channel totalizer, 10–30 Vdc power
0.94 x 1.89 in (24 x 48 mm)
E5-024-E0402
LED multifunction totalizer/timer/ratemeter 10–30 Vdc power
0.94 x 1.89 in (24 x 48 mm)
E5-424-E0402
LED double-function totalizer/timer/ratemeter 10–30 Vdc power
0.94 x 1.89 in (24 x 48 mm)
E5-524-E0402
LED totalizer with quadrature, 10–30 Vdc power
0.94 x 1.89 in (24 x 48 mm)
E5-024-E0432
Description Specification
Supply voltage 10–30 Vdc with reverse polarity protection
Current consumption Max. 55 mA
Display Six-digit red, seven-segment LED display
Figure size 0.31 in (8 mm) high
Data backup EEPROM
Housing Dimension 3.78 x 1.89 in (48 x 24 mm) according to DIN 43 700; RAL 7021 gray
Polarity of inputs Programmable, NPN or PNP
Input resistance Approx. 10k ohms
Counting frequency 60 kHz, can be damped to 30 Hz, position display max. 25 kHz
Resolution Timer 0.001 sec.
Reset time 5 ms
Level of inputs
High 0.6 x UB–30 Vdc
Low 0–0.2 x UB (Vdc)
Error
Tachometer <0.1%
Timer <50 ppm
Ambient temperature 4° to 131°F (–20° to 55°C)
Storage temperature –13° to 167°F (–25° to 75°C)
EMC According to EC EMC directive 89/36/EWG
Immunity to interference EN 61 000-6-4/
EN 55011 Class B
Emitted interference EN 61 000-6-2
Protection IP65 (from front)
Weight Approx. 5.29 oz (150g)
E5-024-C04_
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-45
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Dimensions
Approximate Dimensions in Inches (mm)
1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter
2.32
(59.0)
0.26
(6.5)
0.16
(4.0)
Max. 0.76
(19.3) Connections:
0.87 x 1.77
(22.0 x 45.0)
1.89
(48.0)
Panel Cut-Out:
0.87 + 0.01 x 1.77 + 0.02
(22.2 + 0.3 x 45 + 0.6)
0.94
(24.0)
2.09
(53.0)
1.10
(28.0)
0.98 + 0.02
(25 + 0.5)
1.97 + 0.02
(50 + 0.6)
Panel Cut-Out
0.98 x 1.97
(25 x 50)
0.16
(4.0)
0.04
(1.0)
M3
2.20
(56.0)
1.57
(40)
1.26
(32) 0.98 + 0.02
(25 + 0.5)
1.26 + 0.004
(32 + 0.1)
1.97 + 0.02
(50 + 0.6)
Panel Cut-Out
0.98 x 1.97
(25 x 50)
0.16
(4.0)
0.04
(1.0)
V13-T1-46 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Courier Series
Product Description
Eaton’s Courier Series is a
high quality totalizer powered
by a replaceable lithium
battery.
Features
Eight-digit totalizer
1/Tau ratemeter
Scaling capabilities
Remote reset terminal
0.43 in (10.9 mm) display
Front panel reset
NEMA 4X
Standards and Certifications
CE marked
Product Selection
When Ordering Specify
When ordering Courier Series
Electronic Totalizers and
Ratemeters, specify order
numbers according to the
features selected.
Courier Series, Eight-Digit LCD
Description Catalog Number
Totalizer, battery 53300400
Add/subtract (10k Hz, PNP input) totalizer, battery 53300401
Add/subtract (20 Hz, NPN/contact input) totalizer, battery 53300402
Quadrature (10k Hz, PNP input) totalizer, battery 53300403
Totalizer/ratemeter, battery 53300405
Totalizer/ratemeter at 100 Hz, battery 53300465
RMF panel mount totalizer, key reset, 60–160 Vac/Vdc count input 53300800
RMF panel mount totalizer, dry contact input 53300850
RMF panel mount totalizer, 60–160 Vac/Vdc count input 53300851
Totalizer—extended temperature range, battery 53301400
Totalizer—1/Tau ratemeter—extended temperature range 53301404
Totalizer/ratemeter—extended temperature range, battery 53301405
Totalizer/ratemeter, mag pickup, battery 53301475
Backlight totalizer, battery 53302400
Backlight add/subtract (10k Hz, PNP input) totalizer, battery 53302401
Backlight add/subtract (20 Hz, NPN/contact input) totalizer, battery 53302402
Backlight quadrature (10k Hz, PNP input) totalizer, battery 53302403
Backlight totalizer/ratemeter, battery 53302405
Courier Series
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-47
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
Technical Data and Specifications
General Specifications
Notes
1Derate operating temperature 1°C/volt above 17 Vdc.
2The times are with a 0–5.0V swing.
3The required pulse width varies with count speed, scale factor and number of digits displayed.
Description Specification
Power
Internal battery 3V, lithium
Life expectancy 5 years +
Replacement part 36367-202
Backlight
Backlight 10–30 Vdc at 30 mA max. 1
Reverse polarity protected
Physical
Operating temperature –4° to 158°F (–20° to 70°C)
Storage temperature –4° to 158°F (–20° to 70°C)
Operating humidity 60% non-condensing
Weight 2.2 oz (62g) net
Figure size 0.43 in (10.9 mm) high
Front panel rating NEMA 4X when mounted with gasket provided
Case material Cycolac X-17
Totalizer
Type UP counting
Digits Eight
Count Accuracy
Operated within specifications 100%
DC Common (Terminal 1) Count Inputs
Input B (terminal 2) low speed input designed for
contact closures to DC common
Speed 0 to 20 Hz
Min. low time 10 ms
Min. high time 40 ms
Input impedance 101k ohms
Voltage thresholds
Low 0–0.4 Vdc
High 2.0–28 Vdc
Max. high 28 Vdc
Input A (terminal 3) high speed input requiring a voltage source such
as a current sourcing sensor or a current sinking sensor used with
the provided pull up resistors
Speed 0 to 10 kHz
Min. low time 280 ms
Min. high time 220 ms
Input impedance 2k ohms above 5 Vdc
Voltage thresholds
Low 0–1.2 Vdc
High 2.0–28 Vdc
Max. high 28 Vdc
Reset Input
Reset input (terminal 4) designed for contact closures to
DC common
Min. low 30.25 to 1 sec. (reset is maintained)
Voltage thresholds
Low 0–0.4 Vdc
High 2.0–28 Vdc
Front Panel Reset Enable
Front panel reset enable (terminal 5)
Operation Level sensitive (maintained)
V13-T1-48 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Dimensions
Approximate Dimensions in Inches (mm)
Courier Series
1.30
(33.0)
1.57
(39.9)
1.25
(31.8)
2.67 (67.8)2.95 (74.9)
Recommended
Panel Cutout
T/R RST
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-49
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
To t a l iz er s
1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter
Product Description
LED display for a variety of
input signals.
Features
Display counter adding and
subtracting
Position display
Frequency counter/
ratemeter
Timer, res. up to 0.001
second
Programmable mode
Display range: –199.999 to
999.999 with zero blanking
Connection with screw
terminal
Locking SET-key for reset
Standards and Certifications
UL recognized
CE marked
Product Selection
1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter
Technical Data and Specifications
General Specifications
Note
1For further specifications, please refer to the user manual.
Description Catalog Number
LED Multifunction Counter/Timer/Ratemeter
90–260 Vac power 3.78 x 1.89 in (96 x 48 mm) E5-496-E0401
10–30 Vdc power 3.78 x 1.89 in (96 x 48 mm) E5-496-E0402
Description Specification
Supply voltage 10–30 Vdc with reverse polarity protection; 90–260 Vac
Current consumption Max. 50 mA 6 VA
Display Six-digit red, seven-segment LED display
Figure size 0.55 in (14 mm) high
Data backup EEPROM
Housing Dimension 3.78 x 1.89 in (96 x 48 mm) according to DIN 43 700; RAL 7021 gray
Polarity of inputs Programmable, NPN or PNP for all inputs
Input resistance Approx. 10k ohms
Counting frequency 60 kHz, can be damped to 30 Hz depending on operating mode at position display
max. 25 kHz 1
Reset time 5 ms
Resolution timer Up to 0.001 second
Input switching level
DC version (standard version) High: 0.6 x UB–30 Vdc
Low: 0–0.2 x UB (Vdc)
AC version High: 12–30 Vdc
Low: 0–4 Vdc
Voltage supply for sensors 24 Vdc ±15%/100 mA at AC versions
Accuracy
Tachometer <0.1%
Timer <50 ppm
Ambient temperature –4° to 149°F (–20° to 65°C)
Storage temperature –13° to 167°F (–25° to 75°C)
EMC According to EC EMC directive 89/36/EWG
Immunity to interference EN 61 000-6-4/
EN 55011 Class B
Emitted interference EN 61-000-6-2
Protection IP65 (from front)
Weight Approx. 5.29 oz (150g)
E5-496-E040_
V13-T1-50 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1
Counters, Panel Meters, Tachometers and Timers
Tot a l i ze r s
Dimensions
Approximate Dimensions in Inches (mm)
1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter
3.62 +0.03
(92.0 +0.8)
1.77 +0.02
(45.0 +0.6)
1.89
(48.0)
3.78
(96.0)
1.77 x 3.62
(44.9 x 91.9)
0.61
(15.5)
2.64
(67.1)
0.26
(6.5)
0.16
(4.0)
Max. 0.75
(19.0)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-51
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Count Controls/Preset Counters
Contents
Description Page
Count Controls/Preset Counters
Product Selection Guide . . . . . . . . . . . . . . . . . . . .
V13-T1-52
1/16 DIN Battery Powered LCD
Count Control . . . . . . . . . . . . . . . . . . . . . . . . . . .
V13-T1-53
1/16 DIN LCD Preset Counters with Rate
and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V13-T1-55
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V13-T1-57
President Series (Totalizers). . . . . . . . . . . . . . . . . .
V13-T1-60
Ambassador Series (Totalizers) . . . . . . . . . . . . . . .
V13-T1-69
Ambassador Series (Count Control) . . . . . . . . . . .
V13-T1-72
President Series (Count Control) . . . . . . . . . . . . . .
V13-T1-64
PD-Q and PD-ER Series . . . . . . . . . . . . . . . . . . . .
V13-T1-76
Learn
Online
Product Overview
Count controls are counters
that provide output signal(s)
at preset count value(s).
Typical applications include
cut-to-length, batching, filling,
mixing and dispensing. A
variety of count controls in
different sizes, display types
and feature sets are available
from Eaton.
Application Description
The illustration shows a
simple cut-to-length
application. The roll of paper
is measured using a
measuring wheel and rotary
contactor (or encoder). Once
the desired length is reached,
an output signal may be
directed to a shear for
activation. Following the cut-
off, the count control will
reset to zero and begin
measurement of the next
piece. Options such as batch
counting, where the number
of cut pieces is counted, are
also typical of this application.
Application Example
Rotary Contactor
Roll
Paper
Measuring
Wheel
V13-T1-52 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Product Selection Guide
Count Controls/Preset Counters/Totalizers
Characteristics
Panel Cutout
in Inches (mm) Page
Low cost, simple count control
Battery operated
Easy-to-change preset values
Two-line display: input and preset values
1.772 x 1.772
(45 x 45)
V13-T1-53
Two-line display: counter, timer or tachometer
AC or DC power options
Wide choice of count modes for pulse inputs, time or frequency
Two or four presets
1.772 x 1.772
(45 x 45)
V13-T1-55
Six-digit, super bright LED display
Multiple models available: totalizers, ratemeters, count controls,
digital panel meters and flow controls
1.772 x 3.780
(45 x 96)
V13-T1-57
Six-digit, high-visibility, two-line LCD display
User-configurable control inputs
Highly flexible control/display
2.667 x 2.667
(68 x 68)
V13-T1-72
Bright LED display with 14 mm characters
Simple configuration with 14-button tactile keypad
Many different versions fit almost any application
2.667 x 5.433
(68 x 138)
V13-T1-64
Electromechanical pre-set counter
Easy setpoint adjustment using pushbuttons
Base mount or panel mount
272 x 1.59
(69 x 40.5)
(panel mount model)
V13-T1-76
Integrated controller combines operator interface, ladder logic and
high-speed counting
2.667 x 5.433
(68 x 138)
V13-T1-119
E5-148-C
Eclipse
President
PD-Q and PD-ER
Ambassador
Fusion
E5-648-C
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-53
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
1/16 DIN Battery Powered LCD Count Control
Product Description
Battery-powered electronic
preset counter.
Features
Replacement for
electromechanical preset
counters
No power supply
necessary (battery
operated)
Count and reset input
electrically separated from
counter through
optocoupler input range
12–250 Vac/Vdc
Two-line LC display count,
preset and level of the
output
Screw terminal
Data security, through two
exchangeable lithium
batteries, lifetime
minimum eight years
Easy programming
Counter presets easily via
presetting keys allocated
to each decade
Output: Potential free
relay, programmable
normally open or normally
closed contact
Standards and Certifications
cRU®us approval
CE marked
Product Selection
1/16 DIN Battery Powered LCD Count Control
Technical Data and Specifications
General Specifications
Description Catalog Number
Single Preset Count Control
Battery power 1.89 x 1.89 in (48 x 48 mm) E5-148-C1400
Description Specification
Power supply 2 pcs user exchangeable lithium batteries, type 1/2 AA lithium 3.6V
Display Two-line LCD display, six digits; 999999
Figure size 0.28 in (7 mm) or 0.18 in (4.5 mm) high
Input Reset, count and keylock inputs
Input polarity Bi-directional optocoupler input for the reset count inputs;
reset, count and keyboard lock is connected to 3 Vdc
Input min. pulse duration Reset input 50 ms; keyboard lock input 15 ms
Input switching levels
Low <3 Vac/Vdc
High 12–250 Vac/Vdc
Input frequency Max. 25 Hz
Input resistance 110k ohms
Output Bistable relay with potential free contact (programmable as normally closed or
normally open contact)
Max. switching voltage 250 Vac/220 Vdc
Max. switching current 2A
Max. switching capacity 60 VA/30W
Output response time <20 ms, max. 4 Hz
Data retention Via two batteries, eight years or 5x106 power operations of the output relay and an
ambient temperature of 77°F (25°C)
Ambient temperature 14° to 122°F (–10° to 50°C)
Storage temperature –13° to 140°F (–25° to 60°C)
EMC According to EC EMC directive 89/36/EWG,
EN 61 000-6-4/
EN 55011 Class B,
EN 61 000-6-2
Protection IP65 (front)
Weight Approx. 2.82 oz (80g)
E5-148-C1400
V13-T1-54 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Dimensions
Approximate Dimensions in Inches (mm)
1/16 DIN Battery Powered LCD Count Control
123456 7
123456 7
1.89
(48.0)
1.89
(48.0)
SQ 1.77
(45)
Max. 0.41
(10.5)
2.49
(63.2)
0.63
(16.0)
0.12
(3.0)
2.17
(55.0)
2.17
(55.0)
SQ 1.77
(45)
SQ 1.97
(50)
Max. 0.37
(9.5)
2.45
(62.2)
0.63
(16.0)
0.16
(4.0)
2.95
(75.0)
Flush Bf4, DIN 74
2.36
(60.0)
SQ 1.77
(45)
2.48
(63)
SQ 1.97
(50)
Max. 0.37
(9.5)
2.45
(62.2)
0.63
(16.0)
0.16
(4.0)
Panel Cut-Out 1.77 x 1.77 (45 x 45)
With Front Bezel No. 2
Panel Cut-Out 1.97 x 1.97 (50 x 50)
With Front Bezel No. 3
Panel Cut-Out 1.97 x 1.97 (50 x 50)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-55
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
1/16 DIN LCD Preset Counters with Rate and Time
Product Description
AC or DC powered preset
counters that can function as
timer or tachometer/
ratemeter.
Features
Two-line display with green
backlight (E5-648-C2421
and E5-648-C2422) or
multi-color red/green LED
backlighting (E5-648-
C4461 and E5-648-C4462)
Programmable as preset
counter, batch counter or
totalizer
Power supply: 90–260 Vac
or 10–30 Vdc
Direct input of the presets
via front keys or Teach-In
input
Relay outputs
Scaling by multiplication
and division factors 0.0001
to 99.999
Two preset values, two
outputs
Four preset values, four
outputs
Standards and Certifications
cRU®us approval
CE marked
Product Selection
1/16 DIN Two-Line LCD Count Control
Technical Data and Specifications
General Specifications
Note
1Not a stocked product, contact Eaton Care for assistance.
Description Catalog Number
Two Preset LCD Count Control with Backlighting
90–260 Vac power 1.89 x 1.89 in (48 x 48 mm) E5-648-C2421
10–30 Vdc power 1.89 x 1.89 in (48 x 48 mm) E5-648-C2422
Four Preset LCD Count Control with Multi-Color Display
90–260 Vac power 1.89 x 1.89 in (48 x 48 mm) E5-648-C4461
10–30 Vdc power 1.89 x 1.89 in (48 x 48 mm) E5-648-C4462 1
Description Specification
Power supply 10–30 Vdc external fuse protection
90–260 Vac max. 8 VA external fuse protection
Display Two-line LCD display, six digits with programmable decimal point
Figure size 0.35 in (9 mm) high upper line
0.28 in (7 mm) high lower line
Count inputs Two count inputs (A and B), programmable for count/count direction, up/up, up/down,
quadrature, quad2, quad4, A/B or (A-B)/A x 100%
Input polarity Programmable for all inputs in common NPN/PNP
Input resistance Approx. 5k ohms
Count frequency Max. 55 kHz with programmable filter for 30 Hz (see manual for details)
Input min. pulse duration 10 ms for control inputs/1 ms for reset input
Switching levels
DC supply voltage
High 0.6 x UB–30 Vdc
Low 0–0.2 x UB (Vdc)
AC supply voltage
High 12–30 Vdc
Low 0–4 Vdc
Pulse shape Variable (Schmitt-Trigger characteristics)
E5-648-C_
V13-T1-56 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
General Specifications, continued
Dimensions
Approximate Dimensions in mm [Inches]
1/16 DIN Two-Line LCD Count Control
Description Specification
Output 1
Relay Programmable as normally open or normally closed
Switching voltage max. 250 Vac/110 Vdc
Switching current max. 3A Vac/3A Vdc
Switching current at DC min. 30 mA Vdc
Switching power at DC 90W
Switching power at AC max. 750 VA
Output 2
Relay Relay with changeover/Form C contact
Switching voltage max. 250 Vac/110 Vdc
Switching current max. 3A Vac/3A Vdc
Switching current at DC min. 30 mA Vdc
Switching power at DC 90W
Switching power at AC max. 750 VA
Reaction time of the outputs Approximately 10 ms
Data retention Min. 10 years or 1 million memory cycles
Sensor supply voltage
AC powered unit 24 Vdc ±15%, 80 mA
DC powered unit Max. 80 mA, DC voltage is connected through
Ambient operating temperature 4° to 149°F (–20° to +65°C)
Storage temperature –13° to 167°F (–25° to 75°C)
EMC
Emitted interference EN 55011 Class B
Immunity to interference EN 61000-6-2
Protection IP65 (front)
Weight Approx. 4.4 oz (125g)
15.5
[0.61]
91
[3.583]
7 [0.276]
4.25 [0.167]
45+06
[1.77+0.024]
45+06
[1.77+0.024]
Max. 10.5
[0.413]
45
[1.77]
48
[1.89]
48
[1.89]
Panel Cut-Out
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-57
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Eclipse Series
Product Description
High visibility LED interface
available with a variety of
output options
Features
1/8 DIN cutout
NEMA 4X front panel
Universal AC power supply
(85–265 Vac)
DC power models
(9–30 Vdc)
Removable screw
terminals
Short depth: 3.6 in (91 mm)
Front panel programming
Standards and Certifications
UL and cUL listed
CE marked
Product Selection
LED Count Control, Six-Digit
Totalizers
Technical Data and Specifications
General Specifications
Description Catalog Number
Relay out, 9–30 Vdc power 57700481
Relay out, 85–265 Vac power 57701481
Relay and analog out, 9–30 Vdc power 57700483
Relay and analog out, 85–265 Vac power 57701483
Relay and RS-485 out, 9–30 Vdc power 57700485
Relay and RS-485 out, 85–265 Vac power 57701485
Relay, analog and RS-485 out, 9–30 Vdc power 57700487
Relay, analog and RS-485 out, 85–265 Vac power 57701487
Description Catalog Number
9–30 Vdc power 57700480
Analog out, 9–30 Vdc power 57700482
85–265 Vac power 57701480
Analog out, 85–265 Vac power 57701482
Description Specification
Mechanical
Cutout dimensions 3.62 in W x 1.77 in H (92 mm x 45 mm) DIN standard
Outline dimensions 4.04 in W x 2.19 in H x 3.87 in D (103 mm x 56 mm x 98 mm) 3.60 in (92 mm) maximum
depth in panel
Enclosure Plastic with polyester front label
Connectors Up to six depluggable terminal blocks
Environmental
Operating environment Indoor use to 2000 meters
Temperature
Operating 32° to 122°F (0° to 50°C)
Storage –4° to 158°F (–20° to 70°C)
Humidity 0 to 85% RH, non-condensing
Vibration 2.5 Gs, 30 to 200 Hz
Shock 30 Gs, 11 ms half sinewave
EMC Immunity to EN 50082-2 (heavy industrial)
Emissions to EN 50081-2 (heavy industrial)
Front panel NEMA 4X when mounted with gasket provided
CE EMC immunity and emissions requirements Met using shielded wiring on the RS-485, analog output and pulse input/ power lines.
The shields were connected to earth ground at the Eclipse end of the shields.
Pollution degree 2 Overvoltage Category II
57700481
Eclipse Series
V13-T1-58 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
General Specifications, continued
Description Specification
Input Power
AC powered models (57701-4XX)
Input power 85–295 Vac, 47–63 Hz, 20V A
External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V)
Isolation dielectric strength 2300 Vac
DC powered models (57700-4XX)
Input power 9–30 Vdc, 12V A
External fuse 2.0A, 50 Vdc, time delay (T2A, 50V)
Reverse voltage protection Yes
Isolation dielectric strength 2300 Vac to signal outputs and relays, 500 Vac to RS-485 and analog outputs
Human Interface
Display +6, –5 digits
Type 0.56 in (14.2 mm) high, seven segment, red LED
Data Retention
Memory type EEPROM, no batteries required
Duration 100 years
Count Signal Input
Sensor type Sink or source, DIP switch selectable
Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground
Thresholds
High 3.5–28 Vdc
Low 0–1.9 Vdc, for single ended signals
Magnetic pickup range 200 mV p-p to 65V rms into 34.9k ohms
Slow response 200 Hz max. (DIP switch 2 and/or 5 ON)
Fast response
Count mode A or B
Add/add, add/subtract, add w/Inh 8250/8250
Fast response
Count mode A and B
Add/add, add/subtract, add w/Inh 3000/3000
Quad x1, quad x2 3250
Quad x4 2000
Control Inputs
Sensor type Sink only
Input impedance 4.75k ohms to +5 Vdc
Thresholds
High 3.5 to 28 Vdc
Low 0–1.9 Vdc
Response 25 ms maximum (5V signal)
Accessory Power Output
Voltage 12 Vdc +10%/–13%
Current 75 mA max.
Protection Short-circuit protected
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-59
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Dimensions
Approximate Dimensions in Inches (mm)
Eclipse Series
3.622 ±0 .03
(92.00 ±0.8)
Panel Cutout
Max. Panel Thickness 0.190 (4.83)
4.04
(102.6)
PGM
3.31
(84.1)
3.63
(92.2)
0.27
(6.9)
2.19
(55.6) 1.772 ±0.02
(45 ±0.6)
V13-T1-60 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
President Series (Totalizers)
Product Description
Eaton’s President Series
totalizers are heavy-duty
electronic totalizers with two
available sizes.
Features
Eight-digit, LED display,
0.56 in (14 mm)
Programmable decimal
point and count and rate
scaling
15 Vdc at 100 mA output
power
Rear panel screw terminals
NEMA 4 front panel
Standards and Certifications
UL listed
CSA marked
CE marked
Product Selection
President Series Totalizers
Technical Data and Specifications
General Specifications
Note
1DC power output is only regulated if unit is powered by AC or greater than 18.5 Vdc.
Description Catalog Number
115/230 Vac, LED red display 58811400
115/230 Vac, LED red display, 1/Tau ratemeter 58815400
115 Vac, seven-digit LED red display, basic pulse count 57810400
115/230 Vac, LED red display 58810400
Feet/inches totalizer 57810402
Description Specification
Power Requirements
AC operation 115/230 Vac (+10%, –20%) 47–63 Hz
DC operation 11–28 Vdc
Power 18 watts
DC power output 115 Vdc (+1, –2).
150 mA if powered from AC or less than 24 Vdc
100 mA if powered from 24 Vdc or greater
Environment
Operating temperature 32° to 130°F (0° to 55°C)
Storage temperature –40° to 160°F (–40° to 70°C)
Operating humidity 85% non-condensing relative
Physical
Memory types PROM, RAM, non-volatile NVRAM
President Series
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-61
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
General Specifications, continued
Note
1The count inputs are designed to work with current sinking sensors (open-collector NPN transistor output with or without passive pull-up resistor)
or contact closures to DC common.
Description Specification
Counter
Count range Eight digits (0 to 99,999,999) with rollover
Offset range Eight digits (0 to 99,999,999) (offset is used to reset to a non-zero number)
Count modes Count with add and subtract inputs
Count with up/down direction input (hardware doubling for above modes is
provided)
Count with count inhibit input
Quadrature
Doubled quadrature
Count speed (scale factor of 1.0000 assumed)
58811400 and 58815400 0 to 7,500 counts per second (CPS) with shaft encoders or solid-state sensors
0 to 3,750 CPS when hardware doubling is implemented or when quadrature
shaft encoders are used
0 to 150 CPS when low frequency
is selected
57810400, 58810400 and 57810-402 0 to 10,000 counts per second (CPS) with shaft encoders or solid-state sensors
with internal pull-up resistor
0 to 7,500 CPS minimum for sensors with open collector transistor output
0 to 5,000 CPS when hardware doubling is implemented
Count Input Ratings 1
Input voltage
High state (logical “1“, sensor off or contact open) 10.5–24.5 Vdc when control is powered by AC line
7.0–24.5 Vdc when control is powered by 11 Vdc
11.0–24.5 Vdc when control is powered by 16 Vdc
Low state (logical “0”, sensor on or contact closed) 0–4.5 Vdc when control is powered by AC line
0–3.3 Vdc when control is powered by 11 Vdc
0–4.8 Vdc when control is powered by 16 Vdc
Input impedance 6800 ohms to 15 Vdc when control is powered by AC line
6800 ohms to 10 Vdc when control is powered by DC supply
Input current 20 mA peak, 3 mA steady state
Input response
High state (logical “1”, sensor off or contact open) High speed (low speed jumpers not connected)
110 μS minimum at 15 Vdc (6,800 ohms to +DC)
160 μS minimum at 13.5 Vdc (50,000 ohms to +DC)
High state (logical “1“, sensor off or contact open) Low speed (low speed jumpers connected)
5.5 ms minimum at 15 Vdc (6,800 ohms to +DC)
7.5 ms minimum at 13.5 Vdc (50,000 ohms to +DC)
Low state (logical “0”, sensor on or contact closed) High speed (low speed jumpers not connected)
20 μS minimum at 0.1 Vdc (0 ohms to DC common)
45 μS minimum at 1.5 Vdc (500 ohms to DC common)
Low state (logical “0”, sensor on or contact closed) Low speed (low speed jumpers connected)
1.0 ms minimum at 0.1 Vdc (0 ohms to DC common)
2.0 ms minimum at 1.5 Vdc (500 ohms to DC common)
V13-T1-62 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
General Specifications, continued
Note
1The reset and unlatch signals will both occur in less than 200 microseconds after the input signal is detected.
The start of the print will occur within 2 milliseconds after the input is detected if the unit is not counting.
Description Specification
Scale Factor
Range Five digits (0.0001 to 9.9999)
Control Inputs
Input voltage
High state (logical “1”, contact open) 15 Vdc maximum
Low state (logical “0”, contact closed) 1.2 Vdc maximum
Input impedance 4.75k ohms to +5 Vdc
Threshold
High +3.5 to +22 Vdc
Low +0.0 to +1.0 Vdc
Response time 1
Min. high 5.3 ms
Min. low 3.9 ms
Diagnostic Modes
Diagnostic modes ROM checksum
RAM bit test
NVRAM read/write test
NVRAM store test
NVRAM checksum
Watchdog timer
Display and LED indicator test
Counter Operating Modes
Reset Reset to zero
Reset to offset value
Maintained Reset
Momentary Reset
Communications
Interface type Dual port 20 mA current loop
Speed 110, 300 and 1200 baud, user selectable
Data type Standard ASCII code
Format Start bit, 7 ASCII data bits, parity bit, one or two stop bits
(even parity for serial data output, no parity for serial data input)
Information transmitted Count value
Offset value
Scale factor
Information received Print request
Offset value
Scale factor
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-63
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Dimensions
Approximate Dimensions in Inches (mm)
Standard President Size
Compact President Size
12345
67890
Count
19 20
++
IN OUT
21 22 23 24 25
115/230V~
50/60 Hz
26 27 28 29 30 31 32 33 34 35 36
1234
K1
USE
EXTERNAL
FUSE!
K2
IN1 IN2
56789 101112131415161718
Offset
Count
Preset 1
Reset
Function
Enter
0.95 ±0.04
(24.1 ±1.0)
5.53 ±0.015 (140.5 ±0.4)
5.78 ±0.02 (146.8 ±0.5)
5.91 ±0.03 (150.1 ±0.8)
5.80 ±0.015 (147.3 ±0.4)
5.433 ±0.04
(138 ±1.0)
Recommended
Panel Cutout
2.677 ±0.03
(68 ±0.7)
3.04 ±0.015
(77.2 ±0.4)
0.735 ±0.02
(18.7 ±0.5)
2.62 ±0.025
(66.67 ±0.6)
5.38 ±0.02 (136.7 ±0.5)
6.25 ±0.02 (158 ±0.5)
5.43 ±0.04
(138 ±1.0)
Recommended
Panel Cutout
1.77 ±0.025
(45 ±0.6)
Reset
5.80 ±0.015 (147.3 ±0.4)
2.16 ±0.015
(54.9 ±0.4)
5.53 ±0.015 (140.5 ±0.4)
0.17 ±0.01 (4.3 ±0.24)
1.74 ±0.01
(44.20 ±0.25)
12
++
IN OUT IN1
34567
115/230V~
50/60 Hz
8 9 10 11 12 13 14 15 16 17 18
PR
SWA SWB
IN2
12345678 12345
5.38 ±0.015 (136.7 ±0.4)
V13-T1-64 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
President Series (Count Control)
Product Description
Eaton’s President Series
features an easy-to-read LED
and a simple preset input by
means of the large keypad.
Features
Five- or six-digit, LED
display, 0.56 in (14 mm)
1, 2 or 3 presets
15 Vdc at 100 mA output
power
Rear panel screw terminals
20 mA current loop
communications
2 Form C relays
Tactile keypad NEMA 4
front panel
Standards and Certifications
UL listed
CSA marked
CE marked
Product Selection
President Series Count Control
Notes
1 These models have, in addition to the main count register, a register that may be configured to be used as either a totalizer or single preset batch counter.
These two functions are mutually exclusive.
2 The model 58827-400 has both a totalizer and a batch counter, each with a single preset. In addition, the batch counter may be configured as an additional
totalizer with control instead of batch counter.
3 The model 58827-410 has two completely independent count input channels feeding two independent, single preset count registers. In addition, a third single
preset register may be used as either a totalizer or a batch counter for one or both of the two main counters.
Description
Features
Totalizer
Batch
Counter Rate Scaler Crop-Cut
Main
Counter Presets Digits Catalog Number
120 Vac, no communications —— 1 1 5 57820400
Single preset 1 1 5 58821400
Single preset with rate ✓✓ —1 1558825400
Dual preset —1 2558831400
Dual preset with batch ✓✓ 12658841400
Dual preset with totalizer or batch counter 11✓✓ 12658851400
Three presets with floating pre-warn —1 3658861400
Main counter, batch and totalizer presets 22✓✓ 3 1 ea. 6 58827400
Two independent count registers 33✓✓ 3 1 ea. 6 58827410
High-speed count control—30 kHz max. ✓✓—1 2658867400
President position controller For more details, see Page V13-T1-124 58868400
58831400
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-65
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Technical Data and Specifications
President Series—Count Control
President Series—Count Control, continued
Note
1DC power output is only regulated if unit is powered by AC or greater than 18.5 Vdc.
Description
Model
57820400 57820401 58821400 58825400 58831400
AC power requirements 120V ±10% 240V ±10% 120V/240V +10%/-20%, 47–63 Hz
DC power requirements 11–30 Vdc 11–30 Vdc 11–28 Vdc 11–28 Vdc 11–28 Vdc
Power consumption 8 watts max. 8 watts max. 18 watts max. 18 watts max. 18 watts max.
DC power output 115 Vdc +1/-2 at 85 mA max. 15 Vdc +1/-2; 150 mA if powered from AC or less than 24 Vdc,
100 mA if powered from 24 Vdc or greater
Operating temperature 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C)
Operating humidity 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing
Storage temperature –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C)
Front panel rating NEMA 4 rating when mounted with gasket provided
Main counter scaler range N/A N/A 5 Digits (0.0001 to 9.9999) 5 Digits (0.0001 to 9.9999) 5 Digits (0.0001 to 9.9999)
Count input frequency 10 kHz
(5 kHz in quadrature)
10 kHz
(5 kHz in quadrature)
See table on Page V13-T1-66 See table on Page V13-T1-67 See table on Page V13-T1-66
Count input impedance 6.8k ohms to 15 Vdc when control is powered by AC line;
6.8k ohms to 10 Vdc when control is powered by DC line
Control input threshold High 10.5 to 24.5 Vdc;
Low 0.0 to 4.5 Vdc when powered by AC
Control input impedance 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc
Control input response time Min. high 5.3 ms; min. low 3.9 ms
Relay contact output ratings SPDT Form C; 10 amps resistive at 24 Vdc or 230 Vac; 1/3 hp at 115 Vac or 230 Vac;
150 Vdc max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating
Transistor output ratings Open collector NPN transistor with Zener diode transient surge protection;
30 Vdc max. load; 300 mA max. per transistor; 480 mA total for all transistors.
Use 5 mA per relay coil when calculating total transistor current
Communications N/A N/A Dual port 20 mA current loop, standard ASCII code
Description
Model
58841400 58851400 58827400 58827410 58867400
AC power requirements 120V/240V +10%/-20%, 47–63 Hz
DC power requirements 11–28 Vdc 11–28 Vdc 11–28 Vdc 11–28 Vdc 11–28 Vdc
Power consumption 18 watts max. 18 watts max. 18 watts max. 18 watts max. 18 watts max.
DC power output 115 Vdc +1/-2; 150 mA if powered from AC or less than 24 Vdc,
100 mA if powered from 24 Vdc or greater
Operating temperature 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C)
Operating humidity 85% relative, non-condensing
Storage temperature –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C)
Front panel rating NEMA 4 rating when mounted with gasket provided
Main counter scaler range 5 digits
(0.0001 to 9.9999)
5 digits
(0.0001 to 9.9999)
5 digits
(0.0001 to 9.9999)
5 digits
(0.0001 to 9.9999)
6 digits
(0.00001 to 9.99999)
Count input frequency See table on Page V13-T1-66 See table on Page V13-T1-66 See table on Page V13-T1-66 See table on Page V13-T1-67 See table on Page V13-T1-67
Count input impedance 6.8k ohms to 15 Vdc when control is powered by AC line;
6.8k ohms to 10 Vdc when control is powered by DC line
Control input threshold High 10.5 to 24.5 Vdc;
Low 0.0 to 4.5 Vdc when powered by AC
Control input impedance 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc
Control input response time Min. high 5.3 ms; min. low 3.9 ms
Relay contact output ratings SPDT Form C; 10 amps resistive at 24 Vdc or 230 Vac; 1/3 hp at 115 Vac or 230 Vac;
150 Vdc max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating
Transistor output ratings Open collector NPN transistor with Zener diode transient surge protection;
30 Vdc max. load; 300 mA max. per transistor; 480 mA total for all transistors.
Use 5 mA per relay coil when calculating total transistor current
Communications Dual port 20 mA current loop, standard ASCII code
V13-T1-66 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
58821400 Count Frequency
58831400, 58841400, 58861400 Count Frequency
58851400 Count Frequency
58827400 Count Frequency
Scale Factor
Count Speed (Pulses per Second)
Nominal Count Quadrature and/or Doubled Count
<1.0000 6,250 3,125
1.0000 7,500 3,750
1.9999 5,000 2,500
2.0000 6,250 3,125
9.0000 2,500 1,250
9.9999 2,000 1,000
Count Speed (Pulses per Second)
Scale Factor Nominal Count Quadrature and/or Doubled Count
<1.0000 5,000 2,500
1.0000 7,500 3,750
1.9999 4,000 2,000
2.0000 6,000 3,000
9.0000 2,000 1,000
9.9999 1,500 750
Scale Factor
Count Speed (Pulses per Second)
Function 61 value = “0” Function 61 value = “1”
Nominal Count
Quadrature and/or
Doubled Count Nominal Count
Quadrature and/or
Doubled Count
<1.0000 5,000 2,500 3,500 1,750
1.0000 7,500 3,750 4,500 2,250
1.9999 4,000 2,000 2,400 1,200
2.0000 6,000 3,000 3,600 1,800
9.0000 2,000 1,000 1,100 550
9.9999 1,500 750 1,000 500
Scale Factor
Count Speed (Pulses per Second)
Count Up Count Down Quadrature
0.999 4,000 2,250 2,000
1.000 5,000 3,500 3,500
1.999 3,500 2,000 1,250
2.000 4,000 3,000 2,750
9.000 1,500 1,500 1,500
9.999 1,250 1,000 1,000
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-67
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
58867400 Count Frequency 1
58827410 Count Frequency
58825400 Count Frequency
Notes
1The maximum count input frequency depends only on the selected count mode (doubled or quadrature x4).
The maximum input frequencies shown are with square wave (50% duty cycle) input.
2C1: Counter #1; C2: Counter #2; C3: Counter #3; RM: Ratemeter.
Count Mode
Count Speed (Pulses per Second)
X1 X2 X3
High speed 30,000 15,000 7,500
Low speed 200 200 200
Sample Scale Factor
Count Speed (Pulses per Second)
Typical Combinations of Features 2
C1 = ON
C2 = OFF
C3 = OFF
RM = OFF
C1 = ON
C2 = ON
C3 = OFF
RM = OFF
C1 = ON
C2 = ON
C3 = ON
RM = OFF
C1 = ON
C2 = ON
C3 = OFF
RM = ON
C1 = ON
C2 = ON
C3 = ON
RM = ON
0.0001–0.9999 6,000 3,000 2,300 2,600 2,000
1.0000 9,000 4,500 3,500 4,000 3,000
5.0000 4,500 2,250 1,000 2,000 750
9.9999 1,500 1,000 500 750 550
Scale Factor
Count Speed (Pulses per Second)
Nominal Count Quadrature and/or Doubled Count
<1.0000 4,200 2,100
1.0000 7,500 3,750
1.9999 3,450 1,720
2.0000 6,250 3,120
9.0000 2,500 1,250
9.9999 1,800 900
V13-T1-68 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Dimensions
Approximate Dimensions in Inches (mm)
President Series Count Control
12345
67890
Count
Count
19 20
++
IN OUT
21 22 23 24 25
115/230V~
50/60 Hz
26 27 28 29 30 31 32 33 34 35 36
1234
K1
K1
K2
USE
EXTERNAL
FUSE!
K2
IN1 IN2
5 6 7 8 9 101112131415161718
Preset
Preset 1 Preset 2
Reset
Function
Enter
0.95 ±0.04
(24.1 ±1.0)
5.53 ±0.015 (140.5 ±0.4)
5.78 ±0.02 (146.8 ±0.5)
5.91 ±0.03 (150.1 ±0.8)
5.80 ±0.015
(147.3 ±0.4)
5.433 ±0.04
(138 ±1.0)
Recommended
Panel Cutout
2.677 ±0.03
(68 ±0.7)
3.04 ±0.015
(77.2 ±0.4)
0.735 ±0.02
(18.7 ±0.5)
2.62 ±0.025
(66.67 ±0.6)
5.38 ±0.02 (136.7 ±0.5)
6.25 ±0.02 (158 ±0.5)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-69
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Ambassador Series (Totalizers)
Product Description
Eaton’s Ambassador Series is
our most noise-immune
totalizer available. Various
counting modes can be set
by the user.
Features
AC/DC powered, two-line
LCD display
Eight-digit totalizer
1/Tau ratemeter
Totalizer and ratemeter
scaling
Four user-configurable
control inputs
Two solid-state outputs
RS-485 serial
communications
Standards and Certifications
UL listed
CE marked
Product Selection
Ambassador Series Totalizers
Technical Data and Specifications
General Specifications
Note
1The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input.
Description Catalog Number
10–15 Vdc LCD 57600400
115 Vac LCD 57601400
230 Vac LCD 57602400
Description Specification
Power Input
AC operation 115 Vac (±15%) std., 50 to 60 Hz, 7W
230 Vac (±15%) opt., 50 to 60 Hz, 7W
DC operation 10–15 Vdc opt., 300 mA maximum
DC power output 12 Vdc (±25%), 100 mA maximum (includes all line and load variations)
Environmental
Operating temperature 32° to 131°F (0° to 55°C)
Storage temperature –4° to 158°F (–20° to 70°C)
Operating humidity 85% relative, non-condensing
Rating NEMA 4 when mounted with gasket provided
Totalizer
Type Bi-directional
Digits Eight
Scaler range 0.00001 to 9.99999
Decimal point Five positions, programmable
Totalizer Count Speeds 1
Maximum speed—solid-state (high speed)
Mode Input A/Input B
Add/sub 20 kHz
Add/add 20 kHz
Count/direction 15 kHz
Count x 2/direction 7.5 kHz
Quadrature 6.5 kHz
Quadrature x 2 6.5 kHz
Maximum speed—contact (low speed)
Mode Input A/Input B
Add/sub 40 kHz
Add/add 40 kHz
Count/direction 0 kHz
Ambassador Series
V13-T1-70 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
General Specifications, continued
Description Specification
Count Inputs
Sink
Impedance 4.6k ohms to +5 Vdc
Voltage
High 3.5 to 34.0 Vdc
Low 0.0 to 1.9 Vdc
Source (high)
Impedance 2.3k ohms to common
Voltage
High 3.5 to 17.0 Vdc (100% duty cycle)
Low 0.0 to 1.9 Vdc
Source (low)
Impedance 2.3k ohms to common
DC voltage
High 0.6 to 17.0 Vdc
Low –17.0 to –0.6 Vdc
AC voltage 17 Vac (48V peak-peak) maximum
Control Inputs
Impedance 4.7k ohms to +5 Vdc
Voltage
High +3.7 to +24 Vdc
Low 0.0 to 0.9 Vdc
Response Minimum low 15 ms, minimum high 15 ms
Transistor Outputs (2)
Type NPN open collector with transient protection
Maximum voltage (OFF state) 30 Vdc
Maximum current (ON state) 200 mA at 1.3 Vdc
Communication
Type RS-485
Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit
Protocol Opto-22 compatible
Speed 300, 1200, 2400, 4800, 9600 and 19200 baud
Parity Odd, even, none (space transmitted, ignore received)
Count Accuracy
Operating within specifications 100% when operated within the specified count speeds and count signal high and low times
Rate Indicator
Type 1/Tau
Digits Six
Scaler range 0.00001 to 99999
Decimal point Five positions, programmable
Accuracy ±0.015% of reading
Update time 1 second, fixed
Zero time 10 seconds, fixed
Connections
Type Dual depluggable screw terminal strips
Conductor size 14–22 AWG (2.1–0.38 mm2), 600V, solid, stranded or fused (preferred)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-71
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Dimensions
Approximate Dimensions in Inches (mm)
Ambassador Series Totalizer
1
12
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
2.946 ±0.015
(74.83 ±0.38)
C 123456
P
1
10000
2.946 ±0.015
(74.83 ±0.38)
2.677 ±0.028
(68.00 ±0.70)
2.677 ±0.028
(68.00 ±0.70)
Panel Cutout
Max. Panel
Thickness
0.50 (12.7)
5.60 ±0.03
(142.24 ±0.76)
RST
CLR
RUN
PGM
PRNT
EXIT ENT SEL
Gasket
V13-T1-72 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Ambassador Series (Count Control)
Product Description
Eaton’s Ambassador Series
provides up to four presets in
one of the most noise-
immune packages available.
Features
AC/DC powered, two-line
LCD display
Eight-digit totalizer
1/Tau ratemeter
Totalizer and ratemeter
scaling
Four user-configurable
control inputs
Up to two output relays
Two solid-state outputs
RS-485 serial
communications
Feet/inches control
available
Standards and Certifications
UL listed
CE marked
Product Selection
Ambassador Series Count Control
Technical Data and Specifications
General Specifications
Description Catalog Number
Single preset with rate, 115 Vac 57601401
Single preset with rate, batch and totalizer, 115 Vac 57601402
Dual preset with rate, 115 Vac 57601403
Dual preset with rate, batch and totalizer, 115 Vac 57601404
Four preset with rate, batch and totalizer, 10–15 Vdc 57600405
Four preset with rate, batch and totalizer, 115 Vac 57601405
Four preset with rate, batch and totalizer, 230 Vac 57602405
Feet/inches control, 115 Vac 57601415
Feet/inches control, 230 Vac 57602415
Description Specification
Power Input
AC operation 115 Vac (±15%) std., 50 to 60 Hz, 7W
230 Vac (±15%) opt., 50 to 60 Hz, 7W
DC operation 10–15 Vdc opt., 300 mA maximum
Power Output
DC operation 12 Vdc (±25%), 100 mA maximum (includes all line and load variations)
Environmental
Operating temperature 32° to 131°F (0° to 55°C)
Storage temperature –4° to 158°F (–20° to 70°C)
Operating humidity 85% relative, non-condensing
NEMA 4 rating When mounted with gasket provided
Main Counter
Type Bi-directional
Digits Six
Presets Varies by model
Reset modes Auto or manual reset to zero or preset
Scaler range 0.00001 to 9.99999
Decimal point Five positions (six on four-preset models)
Output latency See table on Page V13-T1-74
Batch Counter
Type Increment with main counter recycle or final preset signal
Digits Six
Presets One
Output latency <1 ms
57601401
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-73
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
General Specifications, continued
Description Specification
Totalizer
Type Bi-directional, same or opposite of main counter
Digits Eight
Scaler Shared with main counter
Decimal point Tracks main counter
Count Input Speeds
See tables on Page V13-T1-74
Count Inputs
Sink
Impedance 4.6k ohms to +5 Vdc
Voltage
High 3.5 to 34.0 Vdc
Low 0.0 to 1.9 Vdc
Source (high)
Impedance 2.3k ohms to common
Voltage
High 3.5 to 17.0 Vdc (100% duty cycle)
Low 0.0 to 1.9 Vdc
Source (low)
Impedance 2.3k ohms to common
DC voltage
High 0.6 to 17.0 Vdc
Low –17.0 to –0.6 Vdc
AC voltage 17 Vac (48V peak-peak) maximum
Control Inputs
Impedance 4.7k ohms to +5 Vdc
Voltage
High +3.7 to +24 Vdc
Low 0.0 to 0.9 Vdc
Response Minimum low 15 ms, minimum high 15 ms
Relay Outputs
Type SPDT contacts
UL ratings 250 Vac, 360V A pilot duty
Transistor Outputs (2)
Type NPN open collector with transient protection
Maximum voltage (OFF state) 30 Vdc
Maximum current (ON state) 200 mA at 1.3 Vdc
Communication
Type RS-485
Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit
Protocol Opto-22 compatible
Speed 300, 1200, 2400, 4800, 9600 and 19200 baud
Parity Odd, even, none (space transmitted, ignore received)
Rate Indicator (Not available on models 57601-415 and 57601-485)
Type 1/Tau
Digits Six
Presets Two
Scaler range 0.00001 to 99999
Decimal point Five positions, programmable
Accuracy ±0.015% of reading
Update time See table on Page V13-T1-74
Zero time See table on Page V13-T1-74
Connections
Type Dual depluggable screw terminal strips
Conductor size 14–22 AWG (2.1–0.38 mm2), 600V, solid, stranded, or fused (preferred)
V13-T1-74 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Output Latency for Ambassador Control
Rate Indicator Specs for Ambassador Control
Ambassador Count Input Speeds—5760X405, 5760X415 1
Ambassador Count Input Speeds—5760X401, 5760X402, 5760X403, 5760X404
Notes
1Contact inputs = 40 Hz; B direction inputs = 40 Hz and B reset input = 10 μS min. low. Input A not active on ft/in control.
2The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input.
Style Number Output Latency
5760X401 0.7 to 2 ms
5760X402 0.7 to 2 ms
5760X403 0.7 to 2.7 ms
5760X404 0.7 to 2.7 ms
5760X405 <1 ms
5760X415 <1 ms
Style Number Update Time Zero Time
5760X401 1 second, fixed 10 seconds, fixed
5760X402 1 second, fixed 10 seconds, fixed
5760X403 1 second, fixed 10 seconds, fixed
5760X40 1 second, fixed 10 seconds, fixed
5760X405 0.1 to 99.9 seconds, programmable 0.1 to 99.9 seconds, programmable
5760X415 0.1 to 999.9 seconds, programmable 0.1 to 999.9 seconds, programmable
Solid-State A or B A and B
A – B 8250/8250 3000/3000
A + B 8250/8250 4000/4000
–A + B 8000/8000 3000/3000
A, B Dir 8000/40
2A, B Dir 4500/40
A, B Rst 8250
Quad x 1 3250
Quad x 2 3250
Quad x 4 2000
Tot A/Cnt B 14000/9000 6500/6500
Tot + Cnt B 16000/8500 6500/6500
Mode
Input A/B
Maximum Speed 2
Solid-State
(High Speed)
Contact
(Low Speed)
Add/sub 20 kHz 40 kHz
Add/add 20 kHz 40 kHz
Count/direction 15 kHz 40 kHz
Count x 2/direction 7.5 kHz
Quadrature 6.5 kHz
Quadrature x 2 6.5 kHz
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-75
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Dimensions
Approximate Dimensions in Inches (mm)
Ambassador Series
1
12
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
2.946 ±0.015
(74.83 ±0.38)
C 123456
P1 10000
2.946 ±0.015
(74.83 ±0.38)
2.677 ±0.028
(68.00 ±0.70)
2.677 ±0.028
(68.00 ±0.70)
Panel Cutout
Max. Panel
Thickness
0.50 (12.7)
5.60 ±0.03
(142.24 ±0.76)
RST
CLR
RUN
PGM
PRNT
EXIT ENT SEL
Gasket
V13-T1-76 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
PD-Q and PD-ER Series
Product Description
The PD-Q Series is a five-
digit, true subtracting electric
predetermined counter that
features pushbutton operation
of both predetermined count
settings and reset. The
predetermined count is set
by holding the RESET button
in and then depressing the
easy to operate pushbutton
selectors under each digit.
The unit subtracts, one count
for each contact closure or
impulse and actuates a
4 ampere, 250 Vac switch
when zero is reached.
The output signal from this
switch can be used to halt or
change the flow of items
being counted, and/or
operate other electrical
apparatus. The counter
returns to the predetermined
number when the RESET
button is depressed and it is
immediately ready to control
the next lot or batch.
The PD-ER Series is identical
to the PD-Q Series, except
that it has electric reset (ER)
for remote operation, allowing
either local or remote use.
Features
Easy setpoint adjustment
Available in base mount or
panel mount configurations
Standards and Certifications
UL recognized as indicated
Product Selection
When Ordering Specify
When ordering PD-Q and
PD-ER Series Predetermined
Counters, specify catalog
numbers according to the
features selected.
PD-Q and PD-ER Series Predetermined Counters
Note
1 UL recognized.
Voltage Mounting Wire Leads Catalog Number Order Number
12 Vdc Panel Rear 5-Y-41433-401-PD-Q 41433401
24 Vdc Panel Rear 5-Y-41433-402-PD-Q 41433402 1
120 Vac Panel Rear 5-Y-41433-406-PD-Q 41433406 1
240 Vac Panel Rear 5-Y-41433-407-PD-Q 41433407
24 Vac Panel Rear 5-Y-41433-408-PD-Q 41433408
24 Vdc Base Rear 5-Y-41469-402-PD-Q 41469402 1
120 Vac Base Rear 5-Y-41469-406-PD-Q 41469406 1
240 Vac Base Rear 5-Y-41469-407-PD-Q 41469407
24 Vdc Base Side 5-Y-41470-402-PD-Q 41470402 1
120 Vac Base Side 5-Y-41470-406-PD-Q 41470406 1
240 Vac Base Side 5-Y-41470-407-PD-Q 41470407
24 Vdc Panel Rear 5-Y-41625-402-PD-ER 41625402 1
120 Vac Panel Rear 5-Y-41625-406-PD-ER 41625406 1
240 Vac Panel Rear 5-Y-41625-407-PD-ER 41625407
5-Y-41433-*-PD-Q
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-77
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
Counters, Panel Meters, Tachometers and Timers
Count Controls/Preset Counters/Totalizers
Technical Data and Specifications
General Specifications
Dimensions
Approximate Dimensions in Inches (mm)
PD-Q and PD-ER Series
Description Specification
Number of digits Five
Speed 1000 cpm
Window Acrylic
Shaft Stainless steel
Frame Zinc alloy die cast
Digit size 3/16 in high by 7/64 in wide (4.8 x 2.8 mm)
Weight
Series PD-Q 0.53 lb (0.24 kg)
Series PD-ER 1.06 lb (0.48 kg)
Finish Dull Instrument black with red RESET button
Power consumption
Series PD-Q 9 watts
Series PD-ER Count coil 9 watts, reset coil 20 watts
Switch rating SPDT, 4 amperes at 250 Vac
1.69
(42.8)
2.69
(68.2)
3.06
(77.8)
Hole Dia.
0.13 (3.2)
1.18
(30.1)
1.56
(39.7)
3.00
(72.6)
3.38
(85.7)
1.59
(40.5)
2.72
(69.0)
2.69
(68.2)
1.56
(39.7)
2.97
(75.4)
Dia. 0.14
(3.6)
3.00
(76.2)
3.38
(85.7)
1.31
(33.3)
1.69
(42.8)
4.38
(111.1)
4.00
(101.6)
2.69
(68.2)
2.00
(50.8)
1.63
(41.3)
3.22
(81.8)
1.69
(42.8)
V13-T1-78 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Tachometers/Ratemeters
Contents
Description Page
Count Controls/Preset Counters
Product Selection Guide . . . . . . . . . . . . . . . . . . V13-T1-79
Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-80
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-82
Ambassador Series . . . . . . . . . . . . . . . . . . . . . V13-T1-85
Learn
Online
Product Overview
Ratemeters are used in a
variety of applications where
it is necessary to monitor the
speed of a process.
Conveyors, baking ovens,
material flow and motor
speed are typical uses for
ratemeters. Models with
alarm outputs can be used to
detect high or low rates. Rate
indicators are often included
as a standard feature on
totalizers and count controls.
Typical Application
One of the most common
ratemeter applications is a
tachometer. A tachometer
displays motor or shaft RPM.
The inductive proximity
sensor detects the key on the
shaft and the meter
calculates the rate at which
the shaft is turning based on
a user-defined scaling factor.
Signals from encoders, mag
pickups, Hall effect sensors,
etc. may also be used as
inputs.
Application Example
High Alarm
Output
0 to 10 Vdc
Feedback to Motor
Drive
Low Alarm
Output
Proximity
Sensor
Motor
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-79
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Product Selection Guide
Tachometers/Ratemeters
Characteristics
Panel Cutout
in Inches (mm) Page
Compact device with bright, LED display
Multiple functions available: count, time, rate, multifunction,
double-function
24 Vdc Power
0.870 x 1.772
(22 x 45)
V13-T1-44
Economical, multifunction display
Large, LED characters
AC or DC power options
1.772 x 3.780
(45 x 96)
V13-T1-49
Bright LED display with 14 mm characters
Simple configuration with 14-button tactile keypad
Many different versions fit almost any application
2.667 x 5.433
(68 x 138)
V13-T1-60
Low cost, simple count control
Various power options: battery, AC, DC
Easy-to-change preset values
Two-line display: input and preset values
1.772 x 1.772
(45 x 45)
V13-T1-53
Replaceable lithium battery
Eight-digit, high-visibility LCD display
Optional backlighting
Various input options available
1.299 x 2.677
(33 x 68)
V13-T1-80
Six-digit, super bright LED display
Multiple models available: totalizers, ratemeters, count controls,
digital panel meters and flow controls
1.772 x 3.780
(45 x 96)
V13-T1-82
Six-digit, high-visibility, two-line LCD display
User-configurable control inputs
Highly flexible control/display
2.667 x 2.667
(68 x 68)
V13-T1-85
Integrated controller combines operator interface, ladder logic and
high-speed counting
2.667 x 5.433
(68 x 138)
V13-T1-119
President
Eclipse
Ambassador
Fusion
Courier
E5-_24-E
E5-496-E
E5-148-C
V13-T1-80 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Courier Series
Product Description
Eaton’s Courier Series is
powered by a replaceable
lithium battery.
Features
1/Tau ratemeter
Scaling capabilities
Remote reset terminal
0.43 in (10.9 mm) display
Front panel reset
NEMA 4X
Standards and Certifications
CE marked
Product Selection
LCD 1/Tau Ratemeter 1
Technical Data and Specifications
General Specifications
Notes
1For units with rate and total, see Totalizers.
2Derate operating temperature 1°C/Volt above 17 Vdc.
Description Catalog Number
Battery 53300404
Extended temperature range, battery 53301404
Backlight, battery 53302404
Description Specification
Power
Internal battery 3V, Lithium
Life expectancy 5 years +
Replacement part 35367-202
Backlight
Backlight 10–30 Vdc at 30 mA max. 2
Reverse polarity protected
Physical
Operating temperature
Model 53300-404 32° to 131°F (0° to 55°C)
Model 53301-404 –4° to 158°F (–20° to 70°C)
Model 53302-404 32° to 131°F (0° to 55°C)
Storage temperature –4° to 158°F (–20° to 70°C)
Operating humidity 60% RH (non-condensing)
Weight 2.2 oz. (62g) net
Display size 0.43 in (10.9 mm) high
Front panel rating NEMA 4X when mounted with gasket provided
Case material Cycolac X-17
Rate Indicator
Type 1/Tau
Digits 4/5 (four calculated, five displayed with fixed 0 in LSD)
Scaler range 0.001 to 9999
Decimal point Five positions, programmable
Accuracy ±0.2%
Update time 0.7 seconds
Zero time 10 seconds
Courier Series
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-81
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
General Specifications, continued
Dimensions
Approximate Dimensions in Inches (mm)
Courier Series Ratemeter
Note
1Times are with a 0–5.0V swing.
Description Specification
DC Common (Terminal 1) Rate Inputs
Input B (terminal 2) low speed input designed for
contact closures to DC common
Speed 0 to 20 Hz
Min. low time 10 ms
Min. high time 40 ms
Input impedance 101k ohm
Voltage thresholds
Low 0–0.4 Vdc
High 2.0–28 Vdc
Max. high 28 Vdc
Input A (terminal 3) high speed input requiring a voltage
source such as a current sourcing sensor or a current
sinking sensor used with the provided pull up resistors
Speed 0 to 10 Hz 1
Min. low time 80 ms 1
Min. high time 20 ms 1
Input impedance 2k ohms above 5 Vdc
Voltage thresholds
Low 0–1.2 Vdc
High 2.0–28 Vdc
Max. high 28 Vdc
Programmable Enable Input (Terminal 5)
Operation Level sensitive (maintained)
Count Accuracy
Operated within specifications 100%
1.30
(33.0)
1.57
(39.9)
1.25
(31.8)
2.67 (67.8)2.95 (74.9)
Recommended
Panel Cutout
T/R RST
V13-T1-82 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Eclipse Series
Product Description
Eaton’s Eclipse Series offers
a high visibility LED and a
variety of optional outputs.
Features
1/8 DIN cutout
NEMA 4X front panel
Universal AC power supply
(85–265 Vac)
DC power modules
(9–30 Vdc)
Removable screw
terminals
Short depth: 3.6 in (91 mm)
Front panel programming
Standards and Certifications
UL and cUL listed
CE marked
Product Selection
Eclipse Series Five-Digit LED Ratemeter
Technical Data and Specifications
General Specifications
Description Catalog Number
9–30 Vdc 57700470
9–30 Vdc, alarms 57700471
9–30 Vdc, analog out 57700472
9–30 Vdc, alarms, analog out 57700473
9–30 Vdc, RS-485 57700474
9–30 Vdc, alarms, RS-485 57700475
9–30 Vdc, alarms, analog out, RS-485 57700477
85–265 Vac 57701470
85–265 Vac, alarms 57701471
85–265 Vac, analog out 57701472
85–265 Vac, alarms, analog out 57701473
85–265 Vac, RS-485 57701474
85–265 Vac, alarms, RS-485 57701475
85–265 Vac, analog out, RS-485 57701476
85–265 Vac, alarms, analog out, RS-485 57701477
Description Specification
Input Power
AC powered models (57701-4XX)
Input power 85–265 Vac, 47–63 Hz, 20V A
External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V)
Isolation dielectric strength 2300 Vac
DC powered models (57700-4XX)
Input power 9–30 Vdc, 12 VA
External fuse 2.0A, 50 Vdc, time delay, (T2A, 50V)
Reverse voltage protection Yes
Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs
Human Interface
Display Five digits
Type 0.56 in high, seven segment, red LED
Indicator One red LED program/calibration indicator
Update time 0.1 to 99.9 seconds minimum
57700470
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-83
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
General Specifications, continued
Description Specification
Data Retention
Memory type EEPROM, no batteries required
Duration 100 years
Signal Input
Rate/process time Signal in
Sensor type Sink or source, DIP switch selectable
Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground
Thresholds
High 3.5 to 28 Vdc
Low 0 to 1.9 Vdc, for single ended signals
Magnetic pickup range 200 mV p-p to 65V rms into 34.9k ohms
Frequency response 200 Hz max. or 10 kHz max. (5V signals), DIP switch selectable
Program Enable Input
Sensor type Sink only
Input impedance 4.75k ohms to +5 Vdc
Thresholds
High 3.5 to 28 Vdc
Low 0 to 1.9 Vdc
Response 25 ms max. (5V signal)
Accessory Power Output
Voltage 12 Vdc ±12%
Current 75 mA max.
Protection Short-circuit protected
Optional Outputs
Relay board
Number of relays Two
Contact type 1 set Form C per relay
Contact rating 5A, 250 Vac or 30 Vdc
Isolation dielectric strength 2300 Vac
Analog retransmission
Output signals 4–20 mA (<750 ohms) and 0–10V (>2500 ohms)
Accuracy 0.13% full scale and 100 PPM/°C (and 0.07% full scale change over 4–20 mA load ranges)
Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to RS-485 and DC power
inputs
RS-485 serial communications
Baud rate 1200, 2400, 4800, 9600, or 19,200, programmable
Parity Even, odd or no parity
Address range 00 to 99 decimal
Protocol Opto 22® compatible
Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and DC
power inputs
Environmental
Operating environment Indoor use to 2000 meters
Temperature
Operating 32° to 122°F (0° to 50°C)
Storage –4° to 158°F (–20° to 70°C)
Humidity 0 to 85% RH, non-condensing
Vibration 2.5 Gs, 30 to 200 Hz
Shock 30 Gs, 11 ms half sinewave
EMC Immunity to EN 50082-2 (heavy industrial)
Emissions to EN 50081-2 (heavy industrial)
Front panel NEMA 4X when mounted with gasket provided
CE EMC immunity and emissions requirements Met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The
shields were connected to earth ground at the Eclipse end of the shields.
Pollution degree 2 Overvoltage Category II
V13-T1-84 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Dimensions
Approximate Dimensions in Inches (mm)
Eclipse Series Ratemeter
Max. Panel Thickness
0.190 (4.83)
3.622 ±0 .031
(92.00 ±0.8)
Panel Cutout
4.04
(102.6)
PGM
3.31
(84.1)
3.63
(92.2)
0.27
(6.9)
2.19
(55.6) 1.772 ±0.02
(45 ±0.6)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-85
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Ambassador Series
Product Description
Eaton’s most noise-immune
ratemeter with an easy-to-
read two-line LCD.
Features
AC/DC powered, two-line
LCD display
Two-line, five-digit, high
visibility, 0.3 in (7.5 mm)
characters, backlit display
One or two rate inputs
Two rate alarms
Dual rate unit ratio
calculations—A/B, A-B or
draw
Programmable average and
zero times
Programmable decimal
point
12 Vdc, 100 mA max.
output power
Removable screw
terminals
RS-485 communications
NEMA 4 front panel
Standards and Certifications
UL and cUL listed
CE marked
Product Selection
Ambassador Series Ratemeter
Technical Data and Specifications
General Specifications
Note
1The accuracy of the ratio calculation is dependent upon the resolution of the displayed rates, which are calculated as rounded integers.
The ratio calculation treats the displayed rate as integers and the result is displayed as a rounded integer.
A and B scalers should be adjusted for maximum resolution.
Description Catalog Number
Single Input
LCD rate indicator, 2 rate alarms, 10–15 Vdc 57150400
LCD rate indicator, 2 rate alarms, 115 Vac 57151400
LCD rate indicator, 2 rate alarms, 230 Vac 57152400
Dual Input 1
Rate/ratio/draw with alarms and analog out, 10–15 Vdc 57150405
Rate/ratio/draw with alarms and analog out, 115 Vac 57151405
Rate/ratio/draw with alarms and analog out, 230 Vac 57152405
Description Specification
Power Input
Model 57150-40X 10 to 15 Vdc, 300 mA maximum
Model 57151-40X 115 Vac (±15%) 50–60 Hz, 7W
Model 57152-40X 230 Vac (±15%) 50–60 Hz, 7W
DC Power Output (AC Models Only)
Output 12 Vdc (±25%), 100 mA maximum (includes all line and load variations)
Environment
Operating temperature 32° to 131°F (0° to 55°C)
Storage temperature –4° to158°F (–20° to 70°C)
Operating humidity 85% relative, non-condensing
NEMA 4 rating When mounted with gasket provided
Ratemeter
Type 1/Tau
Digits Five with overrange indication
Scaler range 0.00001 to 99999
Decimal point Five positions, programmable
Average time 0.1 to 99.9 seconds, programmable
Zero time 0.1 to 99.9 seconds, programmable
Accuracy ±0.015% of reading
57150400
V13-T1-86 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
General Specifications, continued
Maximum Rate Input Frequencies
Maximum frequencies All maximum frequencies listed are with a square wave input (50-50 duty cycle)
Contact Input
Contact input 40 Hz
Solid-State Input
Sinking sensor (all DIPs off) 7.3 kHz
Sourcing sensor (push-pull output)
High threshold (DIPs 1 and 2 on, 3 and 4 off) 0–5V, single input 50 kHz
0–5V, two inputs 30 kHz (each input)
0.5–4.5V, single input 40 kHz
0.5–4.5V, two inputs 30 kHz (each input)
0–15V, two inputs 22 kHz (each input)
Low threshold (all DIPs on) –1 to +1V, single input 27 kHz
–2 to +2V, single input 43 kHz
<–3 to >+3V, single input 60 kHz
<–2 to >+2V, two inputs 30 kHz (each input)
Rate Inputs
Sink
Impedance 4.6k ohms to +5 Vdc
Voltage
High 3.5 to 34.0, low 0.0 to 1.9 Vdc
Source (high)
Impedance 2.3k ohms to common
Voltage High 3.5 to 17.0 Vdc, low 0.0 to 1.9 Vdc
Source (low)
Impedance 2.3k ohms to common
DC voltage High 0.63 to 17.0 Vdc, low –17.0 to –0.6 Vdc
AC voltage 17 Vac (48V peak-peak) maximum
Control Inputs
Impedance 4.7k ohms to +5 Vdc
Voltage High +3.7 to +24 Vdc, low 0.0 to 0.9 Vdc
Response Min, low 15 ms, min, high 15 ms
Transistor Outputs (x2 for 5715X-401; x4 for 5715X-405)
Type NPN open collector with transient protection
Max. voltage (OFF state) 30 Vdc
Max. current (ON state) 200 mA at 1.3 Vdc
Communication
Type RS-485
Format One start bit, seven data bits (ASCII), one parity bit, one stop bit
Protocol Opto-22® compatible
Speed 300, 1200, 2400, 4800, 9600, 19200 baud
Parity Odd, even, none (space transmitted, ignore received)
Analog Output (Models 5715X-401 Only)
Range 0–10 Vdc ± 0.2% at 5 mA
DAC resolution 12 bit
Connections
Type Dual depluggable screw terminal strips
Conductor size 14–22 AWG (2.1–0.38 mm2), 600V, solid, stranded or fused (preferred)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-87
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Counters, Panel Meters, Tachometers and Timers
Tachometers/Ratemeters
Dimensions
Approximate Dimensions in Inches (mm)
Ambassador Series Ratemeters
1
12
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
2.946 ±0.015
(74.83 ±0.38)
A 12345
R/M
2.946 ±0.015
(74.83 ±0.38)
2.677 ±0.028
(68.00 ±0.70)
2.677 ±0.028
(68.00 ±0.70)
Panel Cutout
Max. Panel
Thickness
0.50 (12.7)
5.60 ±0.03
(142.24 ±0.76)
UNL
CLR
RUN
PGM
AKN
EXIT ENT SEL
V13-T1-88 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Digital Panel Meters
Contents
Description Page
Count Controls/Preset Counters
E5-324-E Series. . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-89
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-91
Learn
Online
Product Overview
Digital Panel Meters are
found anywhere a process
variable needs to be
indicated. Volts, current,
pressure, volume,
temperature and frequency
are typical applications. The
product’s short depth makes
it flexible and accommodating
to panel builder needs. A
variety of input and output
options allows DPMs to be
used virtually anywhere.
Typical Application
Monitor current draw from
motor to identify potential
failures
Display pressure reading
from transducer with high-
pressure alarm
Display system voltage and
detect under voltage or
over voltage conditions
Product Selection Guide
Digital Panel Meters
Characteristics
Panel Cutout
in Inches (mm) Page
Bright, easy-to-read LED in 1/32 DIN package
Programmable scaling of inputs
Input for display-hold
24 Vdc power
0.870 x 1.772
(22 x 45)
V13-T1-89
Six-digit, super bright LED display
Multiple models available: DC voltage, AC voltage, DC current,
AC current, 5A AC current, 4–20 mA/0–10V process meter
Various output options including relay, analog and RS-485
1.772 x 3.780
(45 x 96)
V13-T1-91
Eclipse
E5-324-E
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-89
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
E5-324-E Series
Product Description
Eaton’s most compact panel
meter provides an easy-to-
read LED in a very small
package.
Features
Galvanic isolation with
protection against incorrect
polarity
Automatic MIN/MAX value
detection
Freely programmable
characteristic curve end
points
Input Range—
Single current measuring
input (0/4–20 mA)
Single voltage measuring
input (0/2–10V)
Compact display for analog
standard signals
Display range –19.999 to
99.999 with zero blanking
Modern industrial design
Input for display-hold
Standards and Certifications
UL recognized
CE marked
Product Selection
E5-324-E0402 Digital Panel Meter
Technical Data and Specifications
General Specifications
Description Catalog Number
LED digital panel meter, 24 x 48 mm E5-324-E0402
Description Specification
Supply voltage 10–30 Vdc, galvanically isolated with integrated protection against incorrect polarity
Current consumption Max. 50 mA
Display Five-digit display, red seven-segment
LEDs; 0.31 in (8 mm) high
Measuring rate Two measurements/second
Data backup EEPROM
Housing Housing for control panel 1.898 x 0.94 in (48 x 24 mm); acc. to DIN 43 700, RAL 7021,
dark gray
Ambient temperature 14° to 122° F (–10° to 50°C)
EMC According to EC EMC directive 89/36/EEC
Interference emissions EN 61 000-6-4/
EN 55011 Class B
Interference resistance EN 61 000-6-2
Protection IP65 (front)
Input current measurement 0–20 mA, 4–20 mA, voltage drop max. 1.5 Vdc
Input voltage measurement 0–10V, 2–10V
Input resistance approx. 1M ohm
Max. input signal level 30 Vdc
Control inputs
High 4–30 Vdc
Low 0–2 Vdc
Resolution 14 bits
Error <0.1% for the whole measuring range at an ambient temperature of 68°F (20°C)
Weight: Approx 1.76 oz (50g)
Connection technique Screw terminal, pitch 0.2 in (5.08 mm), seven-poles
E5-324-E0402
V13-T1-90 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Dimensions
Approximate Dimensions in Inches (mm)
E5-324-E Series
2.32
(59.0)
0.26
(6.5)
0.16
(4.0)
Max. 0.76
(19.3) Connections:
0.87 x 1.77
(22.0 x 45.0)
1.89
(48.0)
Panel Cut-Out:
0.87 + 0.01 x 1.77 + 0.02
(22.2 + 0.3 x 45 + 0.6)
0.94
(24.0)
2.09
(53.0)
1.10
(28.0)
0.98 + 0.02
(25 + 0.5)
1.97 + 0.02
(50 + 0.6)
Panel Cut-Out
0.98 x 1.97
(25 x 50)
0.16
(4.0)
0.04
(1.0)
M3
2.20
(56.0)
1.57
(40)
1.26
(32) 0.98 + 0.02
(25 + 0.5)
1.26 + 0.004
(32 + 0.1)
1.97 + 0.02
(50 + 0.6)
Panel Cut-Out
0.98 x 1.97
(25 x 50)
0.16
(4.0)
0.04
(1.0)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-91
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Eclipse Series
Product Description
Eaton’s Eclipse Series panel
meter features a high-
visibility LED and is available
with a variety of input and
scaling options.
Features
Four full digits
1/8 DIN Size
Red, LED display
0.56 in (14 mm) high
characters
Scalable display
Flashing alarms
Maximum/minimum data
hold
Optional analog, relay and
RS-485 outputs
NEMA 4X
Depluggable terminal
blocks
Standards and Certifications
UL and cUL listed
CE marked
Eclipse Series Panel Meter
Catalog Number Selection
Eclipse Series
Note
1Output options 0, 2, 4 are not available for models -41X and -43X.
Power Supply
0 = DC (9–30 Vdc)
1 = AC (85–265 Vac)
Output Option 1
0 = No option
1 = Dual relay
2 = Analog output (4–20 mA and 0–10V)
3 = Dual relay, analog output (4–20 mA and 0–10V)
4 = RS-485 communications
5 = Dual relay, RS-485
6 = Analog, RS-485 (4–20 mA and 0–10V)
7 = Dual relay, analog, RS-485 (4–20 mA and 0–10V)
Input Option
0 = DC volt
1 = AC volt TRMS
2 = DC amp
3 = AC amp TRMS
4 = 5A AC TRMS
5 = Process (4–20 mA, 0–10V, 1–5V)
6 = Temperature (J, K, T, PT100 RTD)
5770 X –4XX
V13-T1-92 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Product Selection
Eclipse Digital Panel Meter
Description Catalog Number
9–30 Vdc, DC volt 57700400
9–30 Vdc, DC volt, relay out 57700401
9–30 Vdc, DC volt, analog out 57700402
9–30 Vdc, DC volt, relay out, analog out 57700403
9–30 Vdc, DC volt, RS-485 57700404
9–30 Vdc, DC volt, RS-485, relay out 57700405
9–30 Vdc, AC volt, relay out, analog out 57700413
9–30 Vdc, DC amp 57700420
9–30 Vdc, DC amp, relay out 57700421
9–30 Vdc, DC amp, analog out 57700422
9–30 Vdc, AC amp, relay out 57700431
9–30 Vdc, 5A AC 57700440
9–30 Vdc, 5A AC, relay out 57700441
9–30 Vdc, 5A AC, analog out 57700442
85–265 Vac, DC volt 57701400
85–265 Vac, DC volt, relay out 57701401
85–265 Vac, DC volt, analog out 57701402
85–265 Vac, DC volt, analog out, relay out 57701403
85–265 Vac, DC volt, RS-485 57701404
85–265 Vac, DC volt, RS-485, relay out 57701405
85–265 Vac, AC volt 57701410
85–265 Vac, AC volt, relay out 57701411
85–265 Vac, AC volt, analog out 57701412
85–265 Vac, AC volt, relay out, analog out 57701413
85–265 Vac, AC volt, RS-485, analog out, relay out 57701417
85–265 Vac, DC amp 57701420
85–265 Vac, DC amp, relay out 57701421
85–265 Vac, DC amp, analog out 57701422
85–265 Vac, DC amp, relay out, analog out 57701423
85–265 Vac, DC amp, RS-485, analog out, relay out 57701427
85–265 Vac, AC amp 57701430
85–265 Vac, AC amp, relay out 57701431
85–265 Vac, AC amp, analog out 57701432
85–265 Vac, AC amp, analog out, relay out 57701433
85–265 Vac, AC amp, RS-485 57701434
85–265 Vac, 5A AC 57701440
85–265 Vac, 5A AC, relay out 57701441
85–265 Vac, 5A AC, analog out 57701442
85–265 Vac, 5A AC, analog out, relay out 57701443
85–265 Vac, 5A AC, RS-485, analog out 57701446
Eclipse Series Panel
Meter
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-93
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Eclipse Process
Eclipse Temperature
Description Catalog Number
9–30 Vdc 57700450
9–30 Vdc, relay out 57700451
9–30 Vdc, analog out 57700452
9–30 Vdc, relay out, analog out 57700453
9–30 Vdc, RS-485 57700454
85–265 Vac 57701450
85–265 Vac, relay out 57701451
85–265 Vac, analog out 57701452
85–265 Vac, analog out, relay out 57701453
85–265 Vac, RS-485 57701454
85–265 Vac, RS-485, relay out 57701455
85–265 Vac, RS-485, analog out 57701456
85–265 Vac, relay out, analog out, RS-485 57701457
Description Catalog Number
9–30 Vdc 57700460
9–30 Vdc, relay out 57700461
9–30 Vdc, relay out, analog out 57700463
85–265 Vac 57701460
85–265 Vac, relay out 57701461
85–265 Vac, analog out 57701462
85–265 Vac, relay out, analog out 57701463
85–265 Vac, RS-485 57701464
85–265 Vac, RS-485, analog out, relay out 57701467
V13-T1-94 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Technical Data and Specifications
General Specifications
Description Specification
Input Power
AC powered models (57751-4XX)
Input power 85–265 Vac, 47–63 Hz, 20 VA
External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V)
Isolation dielectric strength 2300 Vac
DC powered models (57750-4XX)
Input power 9-30 Vdc, 12 VA
External fuse 2.0A, 50 Vdc, time delay (T2A, 50V)
Reverse voltage protection Yes
Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs
Human Interface
Display ±4 full digits
Type 0.56 in (14 mm) high, seven segment, red LED
Update time 0.4 seconds
Alarm Flashing display
Indicator One red LED program/calibration indicator with max./min. capture and hold
Data Retention
Memory type EEPROM, no batteries required
Duration 100 years
Signal Input
DC voltage models (5770X-40X)
Range ±199.9m Vdc, ±1.999 Vdc, ±19.99 Vdc, ±199.9 Vdc, DIP switch selectable
Impedance 1M ohm
Overrange 750 Vdc/530 Vac except 220 Vdc/Vac on 199.9 mV range
Accuracy ±0.1% of reading, ±0.03% FS, ±0.5 digit, and ±80 PPM/°C
AC voltage models (5770X-41X)
Range 199.9 m Vac, 1.999 Vac, 19.99 Vac, 199.9 Vac, DIP switch selectable, all ranges true rms
Frequency 40 to 1000 Hz
Impedance 1M ohm (capacity coupled)
Overrange 750 Vdc/530 Vac except 220 Vdc/Vac on 199.9 mV range
Accuracy ±0.5% of reading, ±0.13% FS, ±0.5 digit, ±180 PPM/°C for crest factor = 1; plus ±0.7% for
crest factor = 1 to 3; and ±2.5% for crest factor = 5
DC current models (5770X-42X)
Range ±199.9 μA DC, ±1.999 mA DC, ±19.99 mA DC, ±199.9 mA DC, DIP switch selectable
Impedance 199.9 mV/selected range
Overrange 30 mA (199.9 μA range), 100 mA (1.999 mA range), 300 mA (19.99 mA range), 1A
(199.9 mA range)
Accuracy ±0.1% of reading, ±0.03% FS, ±0.5 digit, and ±120 PPM/°C
AC current models (5770X-43X)
Range 199.9 μA AC, 1.999 mA AC, 19.99 mA AC, 199.9 mA AC, DIP switch selectable,
all ranges true rms
Frequency 40 to 1000 Hz
Impedance 199.9 mV/selected range (shunt output capacitive coupled)
Overrange 30 mA (1199.9 μA range), 100 mA (1.999 mA range), 300 mA (19.99 mA range),
1A (199.9 mA range)
Accuracy ±0.5% of reading, ±0.13% FS, ±0.5 digit, and ±200 PPM/°C for crest factor = 1;
plus ±0.7% for crest factor = 1 to 3; and ±2.5% for crest factor = 5
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-95
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
General Specifications, continued
Description Specification
Signal Input, continued
5A AC models (5770X-44X)
Range 5A AC, true rms
Frequency 40 to 1000 Hz
Impedance 0.02 ohm (shunt output capacitive coupled)
Overrange 10A maximum
Accuracy ±0.4% of reading, ±0.13% FS, ±0.5 digit, and ±200 PPM/°C for crest factor = 1; plus ±0.7%
for crest factor = 1 to 3; and ±2.5% for crest factor = 5
Process models (5770X-45X)
Range 4–20 mA DC, 0–10 Vdc, 1–5 Vdc; separate input terminals for voltage and current signals
Impedance 100 ohms (current input) and 1.27M ohms (voltage input)
Overrange 50 mA maximum (current input) and 100V maximum (voltage input)
Power output 24 Vdc ±10%, 90 mA max, short-circuit protected
Accuracy ±0.1% of reading, ±0.03% FS, ±0.5 digit, and ±80 PPM/°C
Optional Outputs
Relay board
Dual relay 1 set of Form C contacts each
Contact rating 5A, 250 Vac or 30 Vdc
Isolation dielectric strength 2300 Vac
Analog retransmission
Output signals 4–20 mA (<750 ohms) and 0–10V (>2500 ohms)
Accuracy 0.13% FS, 100 PPM/°C, 0.07% FS change with 4–20 mA load, ±0.3% FS for 4–20 mA
output, only after exposure to 85% relative humidity
Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power input; 500 Vac to RS-485 and DC power
inputs
RS-485 serial communication
Baud rate 1200, 2400, 4800, 9600 or 19,200, programmable
Parity Even, odd or no parity
Address range 00 to 99 decimal
Protocol Opto 22® compatible
Isolation dielectric strength 2300 Vac to signal inputs, relays, and AC power input; 500 Vac to analog outputs and DC
power inputs
Environmental
Operating environment Indoor use to 2000 meters
Temperature
Operating 32° to 122°F (0° to 50°C)
Storage –4° to 158°F (–20° to 70°C)
Humidity 0 to 85% RH, non-condensing
Vibration 2.5 Gs, 30 to 200 Hz
Shock 30 Gs, 11 ms half sinewave
EMC/EMI Per EN 61326-1 industrial
Front panel NEMA 4X when mounted with gasket provided
Agency approval CE EMC immunity and emissions requirements were met using shielded wiring on the
RS-485, analog output and signal input lines. The shields were connected to earth ground
at the Eclipse end of the shields.
Conducted emissions requirements were met assuming that the AC signal input would not
be connected directly to the AC mains.
The measurement error during RF immunity testing was less than ±5% of full scale.
In addition, models with an AC signal input had measurement error of less than +25% of
full scale during RF immunity testing of the RS-485 at frequencies below 1 MHz.
Pollution degree 2 Overvoltage Category II
V13-T1-96 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Dimensions
Approximate Dimensions in Inches (mm)
Eclipse Series
Max. Panel Thickness
0.19 (4.8)
3.622 ±0 .031
(92.0 ±0.8)
Panel Cutout
4.04
(102.6)
PGM
3.31
(84.1)
3.63
(92.2)
0.27
(6.9)
2.19
(55.6) 1.772 ±0.02
(45 ±0.6)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-97
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Timers/Hour Meters
Contents
Description Page
Timers/Hour Meters
Product Selection Guide . . . . . . . . . . . . . . . . . . V13-T1-98
Electronic Timers/Hour Meters . . . . . . . . . . . . . V13-T1-99
Electromechanical Timers/Hour Meters . . . . . . V13-T1-105
Learn
Online
Product Overview
Timers are used in
applications where time itself
is the main focus. These
include simple knowledge of
how long a machine has been
running to determine
machine maintenance, for
example, (elapsed time) to
knowing when to
change an
elevator cable (cable life and
safety). Timers
generally
have the ability to stop and
then to continue on from the
point at which they stopped.
Timer relays are used in
applications where an output
is required to make
something happen at a
predetermined point in time
(to stop or start the process).
Typical Application
Elapsed time indication for
interval maintenance of
construction and
agricultural equipment
Usage metering for
determining charges on
rental equipment
Controlled process timing
for adhesive application/
curing equipment
V13-T1-98 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Product Selection Guide
Timers/Hour Meters
Characteristics
Panel Cutout
in Inches (mm) Page
Compact device with bright, LED display
Multiple functions available: count, time, rate, multifunction, double-
function
24 Vdc Power
0.870 x 1.772
(22 x 45)
V13-T1-44
Economical, multifunction display
Large, LED characters
AC or DC power options
1.772 x 3.622
(45 x 92)
V13-T1-49
Non-replaceable battery (minimum eight-year life)
Compact, low cost and high efficiency
Eight-digit LCD timer
Manual or electrical reset
Various timing modes (Hr/Min/Sec)
0.870 x 1.772
(22 x 45)
V13-T1-100
Compact, low-cost LCD and electromechanical elapsed time meters
Various power options for almost any power supply
Various V13-T1-105
Combination counter consists of time meter and adding counter in one
Without reset
High shock resistance
Magnified figures
Protection IP52 (front)
Data retention if power is lost
Long service life
UL Approved
1.988 (50.5) dia. or
DIN rail
V13-T1-111
E5-_24-E
E5-496-E
Hour Meters
Hour Meter/Counter
E5-224-C
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-99
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Electronic Timers/Hour Meters
Contents
Description Page
Electronic Timers/Hour Meters
1/32 DIN LCD—Timers . . . . . . . . . . . . . . . . . . . V13-T1-100
E42DI24/E42DIR Series . . . . . . . . . . . . . . . . . . V13-T1-103
Electromechanical Timers/Hour Meters . . . . . . . . V13-T1-105
Electronic Timers/Hour Meters
Product Overview
Eaton’s electronic hour
meters are a simple and
effective way to monitor
equipment on time.
Features
Reset or non-reset
Variety of power options
LCD displays
Standards and Certifications
UL recognized
CE
V13-T1-100 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
1/32 DIN LCD—Timers
Product Description
Simple battery-powered
timers provide an easy-to-
read LCD and a variety of
timing display options.
Features
Low price and high
efficiency
Large eight-digit LCD
display, height of the
figures 0.31 in (8 mm)
Different time ranges from
0.1 second to 100,000
hours
0.1 second synchronization
makes it suitable for very
short activation times
High voltage input for
10–260 Vac/Vdc voltage
pulses
IP65
Screw terminals,
RM 5 mm
Lifetime of the battery
approximately eight years
Locking of the reset key
Operating temperature
1 to 140°F (–10° to 60°C)
Standards and Certifications
UL recognized
CE marked
Product Selection
1/32 DIN LCD Timers
Technical Data and Specifications
General Specifications
Description Catalog Number
Eight-Digit LCD Timer, Battery Power
Hours/minutes, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0440
Hours/minutes, 10–260V input, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0448
Minutes/seconds, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0450
Minutes/seconds, 10–260V input 0.94 x 1.89 in (24 x 48 mm) E5-224-C0458
Description Specification
Power supply Non-replaceable lithium battery (lifetime approximately eight years at 68°F (20°C)
Display LCD, eight-digits
Figure size 0.31 in (8 mm) high
Counting direction Adding
Display range
Time range 99999h 59m (134)
Display
Time range 99999.99h (134)
Display
Time range 9999h 59m 59s (135)
Display
Time range 9999999.9s (135)
Display
Reset Manual and electrical
E5-224-C04_
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-101
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
General Specifications, continued
Description Specification
Timer inputs, DC versions (max. 30 Vdc)
Timer input NPN or PNP depending on the type
Switching level
NPN low 0–0.7V
NPN high 3–30 Vdc
PNP low 0–0.7V
PNP high 4–30 Vdc
Counting start
NPN For low signal at the timer input
PNP For high signal at the timer input
Timer inputs, high voltage version (10–260 Vdc/Vac)
Timer input Optocoupler input max. 30 Hz
Min. pulse time 16 ms
Switching level
Low 0–2 Vdc/Vac
High 10–260 Vdc/Vac
Counting start For high signal at the timer input
Time range change (mode)
Contact input—open collector (switching at 0V)
NPN low 0–0.7V
NPN high 3–5 Vdc
Time range Depending on the circuit
Reset Input (only DC and high voltage)
Minimum pulse time
DC 50 ms
High voltage 10 ms
Contact input (DC)
NPN low 0–0.7V
NPN high 3–30 Vdc
High voltage input 10–260 Vdc/Vac
Reset locking input (for DC and AC),
electrical reset key locking
Input not active Reset key locked
Contact input Open collector NPN (switching at 0V)
Switching level
NPN low 0–0.7V
NPN high 3–5 Vdc
Interference emissions EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions)
Housing Dark gray RAL 7021
Operating temperature 14° to 131°F (–10° to 55°C)
Ambient temperature 14° to 140°F (–10° to 60°C)
Storage temperature –4° to 158°F (–20° to 70°C)
Protection IP65 (from front)
Weight Approx. 1.76 oz (50g)
V13-T1-102 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Dimensions
Approximate Dimensions in Inches (mm)
1/32 DIN LCD Timers
1.77
+ 0.024
(45
+ 0.6
)
1.7 7
+ 0.012
(22.2
+0.3
)
1.89 (48)
MAX. 1.89 (19.3)
0.11 (2.8)
0.12 (3)
1.88 (47.7)
0.87 x 1.77
(22 x 45)
0.94
(24)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-103
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
E42DI24/E42DIR Series
Product Description
Simple LCD hour meters with
flexible input voltages
Features
Solid-state hour meters
Record and display up to
99,999.9 hours, rollover
and continue timing
EEPROM memory can
retain data for 25+ years
Time accumulation
indicated by flashing
hourglass icon
Memory will arm only
when power has been
applied for 5 seconds
Standards and Certifications
UL recognized
CE compliant
Product Selection
E42DI24/E42DIR Series Elapsed Time Meters
Technical Data and Specifications
General Specifications
Description Catalog Number
Round LCD
Elapsed hour meter, 48–150 Vdc/100–230 Vac E42DIR48230
Elapsed hour meter with reset, 48–150 Vdc/100–230 Vac E42DIR48230R
Elapsed hour meter, 12–48 Vdc/20–60 Vac E42DIR1260
Rectangular LCD
Elapsed hour meter, 48–150 Vdc/100–230 Vac E42DI2448230
Elapsed hour meter, with reset, 48–150 Vdc/100–230 Vac E42DI2448230R
Elapsed hour meter, 12–48 Vdc/20–60 Vac E42DI241260
Description Specification
Function Solid-state hour meter
Power supply
E42DIXX1260X 12–48 Vdc ±25%/20–60 Vac ±25%
E42DIXX48230X 48–150 Vdc +23%–25%/100–230 Vac +17%–25%
Frequency range 48–440 Hz
Display Six-digit LCD, 0.20 in (5 mm)
Accuracy ±0.1%
Recording/display capacity 99,999.9 hours
Resolution 0.1 hour (6 minutes)
Current consumption max. at nominal voltage
E42DIXX1260X 0.8 mA at 12 Vdc
5.0 mA at 48 Vdc
0.5 mA at 20 Vac
2.5 mA at 60 Vac
E42DIXX48230X 0.8 mA at 48 Vdc
2.5 mA at 150 Vdc
0.9 mA at 100 Vac
2.0 mA at 230 Vac
Input impedance minimum (pins 3 and 4)
E42DIXX1260X 70k ohms
E42DIXX48230X 480k ohms
Operating temperature –40° to 185°F (–40° to 85°C)
Storage temperature –58° to 194°F (–50° to 90°C)
Weight
E42DIRXXXXXX 1.94 oz (55g)
E42DI24XXXXXX 0.78 oz (22g)
E42DIR_
E42DI24_
V13-T1-104 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Dimensions
Approximate Dimensions in Inches (mm)
E42DI24/E42DIR Series
1.40
(35.6)
0.89
(22.6)
1.22
(31.1)
1.75
(44.5)
2.00
(53.1)
Dia. 2.30
(58.4) Max.
Dia. 2.06
(52.3) Max.
U Clamp for
0.03 – 0.25 (7.6 – 6.4)
Panel Thickness
Black Bezel
Washer
Thumbnut 0.16 (4.0)
Terminal 0.25
(6.4) Max.
0.52 (13.2)
Max.
1.13
(28.7)
0.06
(1.5)
Terminal
0.25 (6.4)
0.93 (23.6) 0.95 +0.01
-0.00
(24.1 +0.25
-0.00)
1.45 +0.01
-0.00
(36.8 +0.25
-0.00)
0.71
(18)
0.18
(4.7)
0.35 (8.9)
Max.
1.13 (28.6)
Max.
HOURS
1/10
HOURS
QUARTZ
1
10
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-105
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Electromechanical Timers/Hour Meters
Contents
Description Page
Electronic Timers/Hour Meters . . . . . . . . . . . . . . . V13-T1-99
Electromechanical Timers/Hour Meters
1/16 DIN Hour Meters . . . . . . . . . . . . . . . . . . . V13-T1-106
71.1 Round Hour Meters . . . . . . . . . . . . . . . . . V13-T1-109
Hour Meter/Counter . . . . . . . . . . . . . . . . . . . . . V13-T1-111
Electromechanical Timers/Hour Meters
Product Overview
Eaton’s electromechanical
hour meters are available in a
variety of configurations and
provide a cost-effective way
to monitor equipment on
time.
Features
Non-resettable
Always readable display
Standards and Certifications
UL recognized
CE
V13-T1-106 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
1/16 DIN Hour Meters
Product Description
Eaton’s most cost-effective
elapsed time meter. Features
IP65 protection against water
intrusion.
Typical Application
General elapsed time
Service interval for
measurement systems—
Respiratory ventilators
Oxygen machines
Dialysis machines
Small appliances
UV lamps
Display panels in cars
Features
High shock resistance
Without reset
Small dimension
Magnified figures
Protection IP65
Data retention if power is
lost
Long service life
Optional mounting position
Standards and Certifications
UL recognized
Product Selection
1/16 DIN Hour Meters
DIN Rail Adapter
Description Catalog Number
10–30 Vdc, 1.89 x 1.89 in (48 x 48 mm) 8-T-65-4848PM-402
100–130 Vac, 1.89 x 1.89 in (48 x 48 mm) 7-T-65-4848PM-406
Description Catalog Number
DIN rail adapter for DIN electromechanical hour meter T4848DINADAPT
7-T-65-4848PM-40_
T4848DINADAPT
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-107
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Technical Data and Specifications
General Specifications
Description Specification
Electrical connection Clamp terminal for cable diameter up to 14 AWG (2.5 mm2),
tightening torque max. 0.59 lb-ft (0.8 Nm)
Power consumption
10–30 Vdc Approx. 500 mW
100–130 Vdc Approx. 750 mW
Rated voltages 100–130 Vac, 50 or 60 Hz
10–30 Vdc
On time 100%
Display
Seven at AC 99999.99
Eight at DC 999999.99
Accuracy
AC Supply frequency + 30 ms
DC <0.003% (24h)
Count mode Adding
Figure size 0.16 in (4 mm) high
Color of figures White and red-on-black
Ambient temperature 5° to 122°F (–15° to 50°C)
Mounting position Any
Protection IP65
Housing Plastic
Weight 1.7 oz (48g)
Operating indicator of the running time meter
AC Fast rotating wheel with red dashes
DC 1/100h display turns continuously by 1-digit in 36 seconds
Test voltage 2000 Vac, 50 Hz for AC counters
Options Further voltages on request
Color of housing Gray
V13-T1-108 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Dimensions
Approximate Dimensions in Inches (mm)
1/16 DIN Hour Meters
DIN Rail Adapter
1.10
(28)
0.28
(7)
0.35 (9)
Max.
Dia. 1.97
(50)
1.77+0.02 (45+0.6)
SQ.
Panel Cut-Out
1.77 (45) SQ.
Screw
Terminal
1.89 (48) SQ.
2.42
(61.5)
1.91
(48.5)
0.75
(19)
1.62
(41.1)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-109
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
71.1 Round Hour Meters
Product Description
Eaton’s 6-T-3H hour meters
are heavy-duty elapsed time
meters with NEMA 4X
protection.
Typical Application
General elapsed time
Utility vehicles
Construction machines
Generators
Fork-lift trucks
Car washes
Outside areas
Features
Six-digit hour meter for
round panel cut-out
Low cost
High shock resistance
Low power consumption
Small dimension
Magnified figures
Waterproof
NEMA Type 4X rating
Data retention if power is
lost
Available in 50 pc. bulk
package
Standards and Certifications
UL recognized
Product Selection
71.1 Round Hour Meters
Technical Data and Specifications
General Specifications
Description Catalog Number
115 Vac, 2.80 in (71.1 mm) round 6-T-3H-508RPM-406
10–80 Vdc, 2.80 in (71.1 mm) round 6-T-3H-508RPM-402
Description Specification
Electrical connection Flat pins 0.8 x 6.3
Power consumption
AC Max. 0.4 VA
12 Vdc Max. 0.08W
48 Vdc Max. 0.7W
Rated voltages 115 Vac ±10%, 50/60 Hz, 10–80 Vdc
On time 100%
Display Six-digits, 99999.9h
Count mode Adding
Figure size 0.14 in (3.5 mm) high
Reset None
Ambient temperature –22° to 149°F (–30° to 65°C)
Mounting position Any
Protection IP65
Housing Plastic
Error <0.02% over the full range
6-T-3H-508RPM-40_
V13-T1-110 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Dimensions
Approximate Dimensions in Inches (mm)
71.1 Round Hour Meter
0.21
(5.3)
1.26
(32)
0.47
(12)
1.68
(42.7)
0.03 x 0.25
(0.8 x 6.3)
Dia. 2
(50.8)
Dia. 2
(50.8)
120°
Dia. 0.15
(3.8)
Dia.
0.13
(3.3)
Dia. 2.80
(71.1)
Dia. 2.44
(62)
Dia. 2.54
(64.5)
Panel Cut-Out
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-111
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Hour Meter/Counter
Product Description
Eaton’s CEC series
combination meters provide
an event counter and elapsed
time meter is one compact
unit.
Typical Application
General counting
Pump control panels
Service interval for
measurement systems
(respiratory ventilators,
oxygen machines, dialysis
machines)
Small appliances
UV lamps
Display panels in cars
Features
Combination counter
consists of time meter and
adding counter in one
Without reset
High shock resistance
Magnified figures
Protection IP52 (front)
Data retention if power is
lost
Long service life
Standards and Certifications
cRU®us certified
CE marked
Product Selection
Hour Meter/Counters
Technical Data and Specifications
General Specifications
Description Catalog Number
Combination hour meter/counter, 55 mm square front panel mount,
100–130 Vac, 60 Hz
CEC-55PM-406
Combination hour meter/counter, 48 mm DIN rail mount, 100–130 Vac, 60 Hz CEC-48DR-406
Description Specification
Electrical connection Flat pin 0.8 x 6.3 mm with screw terminal, tightening torque max. 0.8 Nm
Power consumption
100–130 Vac 60 Hz, approx. 1.43 VA
Count mode Adding
Figure size 0.16 x 0.07 in (4 x 1.7 mm)
Color of figures
Hour White on black
Decimal Red on black
Running time meter operating indicator Fast rotating wheel with red dashes; 99999.99 hour
Accuracy AC Supply frequency ±30 ms
Reset None
Ambient temperature 5° to 122°F (–15° to 50°C)
Mounting position Any
Color of housing Black
CEC-…-406
V13-T1-112 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.5
Counters, Panel Meters, Tachometers and Timers
Timers/Hour Meters
Dimensions
Approximate Dimensions in Inches (mm)
DIN Rail Mount
Front Panel Mount
h
2.106
(53.5)
0.197
(5.0)
2.421
(61.5)
SQ 1.91
(48.5)
0.748
(19.0)
0.047
(1.2)
h
Dia. 1.988
(50.5)
0.047 (1.2)
0.374 (9.5)
1.122
(28.5)
SQ 2.166
(55.0)
0.256 (6.5) Max.
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-113
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.6
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
Flow Totalizers, Transmitters and Controls
Contents
Description Page
Flow Totalizers, Transmitters and Controls
Product Selection Guide . . . . . . . . . . . . . . . . . . V13-T1-113
Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-114
Learn
Online
Product Overview
Flow products are used in a
variety of applications where
liquid gas flow needs to be
monitored or controlled.
Eaton offers models for flow
total, flow rate and flow batch
control. Several optional
outputs allow great flexibility
to meet most application
needs.
Typical Application
In many processes, it is
desirable to know both the
total quantity of product
being produced and the rate
at which the product is being
produced.
In the illustration at right, the
output of a turbine flow
sensor is connected to a
totalizer/ratemeter. The flow
sensor produces a known
number of pulses per gallon
(or other unit of measure).
The instrument scales these
pulses into the desired units
of flow volume (gallons,
liters, barrels, etc.), and flow
rate (gallons/minute, barrels/
hour, etc.).
Application Example
Product Selection Guide
Totalizers
Characteristics Typical Applications
Panel Cutout
in Inches (mm) Page
Six-digit, super bright LED display
Multiple models available: totalizers,
ratemeters, count controls, digital
panel meters and flow controls
Length measurement and control
Flow monitoring and control
Process monitoring and display
Voltage and current monitoring and
display
1.772 x 3.780
(45 x 96)
V13-T1-114
Liquid
53300-405
To t a l i z e r/ R a t e m e t e r
Flow Sensor
Eclipse
V13-T1-114 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.6
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
Eclipse Series
Product Description
Eaton’s Eclipse series flow
totalizer and controller can
accept signals from analog
flow meters and display flow
rates and volumes on a high-
visibility LED.
Features
Six- or 10-digit display
1/8 DIN size
Red, LED display
0.56 in (14 mm) high
characters
Scalable display
Analog or pulse input
versions
Accessory power output
15-point linearization
available
Dual valve pre-warn
available
Optional analog, relay and
RS-485 outputs
NEMA 4X
Depluggable terminal
blocks
Standards and Certifications
UL and cUL listed
CE marked
Eclipse Series
Flow Totalizer and Control
Catalog Number Selection
Eclipse Flow Model
Note
1Output options 0, 2, 4 are not available for models -41X and -43X.
Power Supply
0 = DC (9–30 Vdc)
1 = AC (85–265 Vac)
Input Option
0 = Pulse input totalizer/ratemeter
1 = Pulse input batch control
2 = Analog input totalizer/ratemeter
3 = Analog input batch control
Output Option 1
0= No option
1= Dual relays (standard or batch)
2= Analog output (4–20 mA and 0–10V)
3= Dual relays and analog output
4= RS-485 communications
5= Dual relay and RS-485
6= Analog output and RS-485
7= Dual relays, analog output and RS-485
A= One relay, one transistor
B= One relay, one transistor, analog output
C= One relay, one transistor, RS-485
D= One relay, one transistor, analog output and RS-485
5775 X –4XX
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-115
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.6
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
Product Selection
Eclipse Series Totalizer Display Preset Counters
Description Catalog Number
Flow total rate, DC, pulse input 57750400
Flow total rate, DC, pulse input, dual relay out 57750401
Flow total rate, DC, pulse input, analog out 57750402
Flow total rate, DC, pulse input, dual relay out, analog out 57750403
Flow total rate, DC, pulse input RS-485 57750404
Flow batcher, DC, pulse input, dual relay out 57750411
Flow batcher, DC, pulse input, dual relay out, RS-485 57750415
Flow total/rate, DC, analog input 57750420
Flow total/rate, DC, analog input, dual relay out 57750421
Flow total/rate, DC, analog input, analog out 57750422
Flow total/rate, AC, pulse input 57751400
Flow total/rate, AC, pulse input, dual relay out 57751401
Flow total/rate, AC, pulse input, analog out 57751402
Flow total/rate, AC, pulse input, dual relay out, analog out 57751403
Flow total/rate, AC, pulse input, analog out 57751404
Flow batcher, AC, pulse input, dual relay out 57751411
Flow batcher, AC, pulse input, dual relay out, analog out 57751413
Flow batcher, AC, pulse input, dual relay out, RS-485 57751415
Flow total/rate, AC, analog input 57751420
Flow total/rate, AC, analog input, dual relay out 57751421
Flow total/rate, AC, analog input, analog out 57751422
Flow total/rate, AC, analog input, dual relay out, analog out 57751423
Flow total/rate, AC, analog input, analog out, RS-485 57751426
Flow batcher, AC, analog input, dual relay out 57751431
Flow total/rate, AC, pulse input, relay/transistor out 5775140A
Flow total/rate, AC, pulse input, relay/transistor out, analog out, RS-485 5775140D
Flow total/rate, AC, analog input, relay/transistor out 5775142A
Flow total/rate, AC, analog input, relay/transistor out, analog 5775142D
Flow batcher, AC, analog input, relay/transistor out, analog 5775143D
Eclipse Series
Totalizer Display
Preset Counter
V13-T1-116 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.6
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
Technical Data and Specifications
General Specifications
Description Specification
Input Power
AC powered models (57751-4XX)
Input power 85–265 Vac, 47–63 Hz, 20 VA
External fuse 0.2A, 250 Vac, time delay (T200mA, 250V)
Isolation dielectric strength 2300 Vac
DC powered models (57750-4XX)
Input power 9–30 Vdc, 12 VA
External fuse 2.0A, 50 Vdc, time delay (T2A, 50V)
Reverse voltage protection Yes
Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs
Human Interface
Display Six digits
Type 0.56 in high, seven segment, red LED
Data Retention
Memory type EEPROM, no batteries required
Duration 100 years
Count Signal Input/Count Inhibit Signal Input
Sensor type Sink or source, DIP switch selectable
Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground
Thresholds
High 3.5 to 28 Vdc
Low 0 to 1.9 Vdc, for single ended signals
Magnetic pickup range 50 mV p-p to 65V rms into 34.9k ohms
Slow response 50 Hz max. (DIP switch 2 and/or 5 ON)
Flat response 10 kHz
Flow Signal Input (Analog Input Models)
Types 4–20 mA and 0–10 Vdc
Input impedance 100 ohms (current input), 1.27M ohms (voltage input)
Overrange 50 mA max. (current input), 100V max. (voltage input)
Accuracy ±0.1% of reading, ±1 digit, and ±80 PPM/°C
Control Inputs
Sensor type Sink only
Input impedance 4.75k ohms to +5 Vdc
Thresholds
High 3.5 to 28 Vdc
Low 0 to 1.0 Vdc
Response 25 ms maximum (5V signal)
Accessory Power Output (Pulse Input Models)
Voltage 12 Vdc +10%/–13%
Current 75 mA max.
Protection Short-circuit protected
Accessory Power Output (Analog Input Models)
Voltage 24 Vdc ±10%
Current 90 mA max.
Protection Short-circuit protected
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-117
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.6
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
General Specifications, continued
Description Specification
Relay/Transistor Outputs (Standard on Batch Controls, Optional on Totalizers)
Number Two relays or one relay and one transistor
Relay contact type One set Form C per relay
Relay contact rating 5A, 250 Vac or 30 Vdc
Transistor type NPN, opto isolated
OFF state block 30 Vdc max., 0.1 mA max. leakage current
ON state conduct 50 mA max., 1.2 Vdc max. C-E drop
Max. switching frequency 4 kHz (50-50 duty cycle)
Isolation dielectric strength 2300 Vac
Optional Outputs
Analog retransmission
Output signals 4–20 mA (<750 ohms) and 0–10V (>2500 ohms)
Accuracy 0.13% full scale and 100 PPM/°C (and 0.07% full scale change over 4–20 mA load ranges
Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and
DC power inputs
RS-485 serial communications
Baud rate 1200, 2400, 4800, 9600, or 19,200, programmable
Parity Even, odd or no parity
Address range 00 to 99 decimal (00 indicates off line)
Protocol Opto 22® compatible
Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and
DC power inputs
Environmental
Operating environment Indoor use to 2000 meters
Temperature
Operating 32° to 122°F (0° to 50°C)
Storage –4° to 158°F (20° to 70°C)
Humidity 0 to 85% RH, non-condensing
Vibration 2.5 Gs, 30 to 200 Hz
Shock 30 Gs, 11 ms half sinewave
EMC Immunity to EN 50082-2 (heavy industrial)
Emissions to EN 50081-2 (heavy industrial)
Front panel NEMA 4X when mounted with gasket provided
Agency approval CE EMC immunity and emissions requirements were met using shielded wiring on the
RS-485, analog output and pulse input/power lines. The shields were connected to earth
ground at the Eclipse end of the shields.
Pollution degree 2 Overvoltage Category II
V13-T1-118 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.6
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
Dimensions
Approximate Dimensions in Inches (mm)
Eclipse Flow Models
PGM
View
Edit
Enter
Start
Stop
Reset
PGM
BATCH
3.622 ±0 .031
(92.00 ±0.8)
Panel Cutout
4.04
(102.6)
3.31
(84.1)
3.63
(92.2)
0.27
(6.9)
2.19
(55.6) 1.772 ±0.02
(45 ±0.6)
Max. Panel Thickness
0.190 (4.83)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-119
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.7
Counters, Panel Meters, Tachometers and Timers
Fusion Integrated Machine Control
Fusion Integrated Machine Control
Contents
Description Page
Fusion Integrated Machine Control
Standards and Certifications . . . . . . . . . . . . . . . V13-T1-120
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V13-T1-120
Technical Data and Specifications . . . . . . . . . . . V13-T1-121
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-123
Learn
Online
Fusion Integrated Machine Control
Product Description
The Fusion® Integrated
Machine Control has
advanced features, including
a five-preset high speed
counter with pre-warn, a
totalizer with preset, a batch
counter with preset and a
ratemeter with high and low
setpoints. Unique to the
count control world, the
Fusion has five output relays
(rather than two), along with
two transistors and two
analog setpoint or follower
outputs. Its ten available
parameter sets of pre-loaded
values are useful as recipes,
for job-stacking or for a
variety of application-specific
purposes.
The Fusion has a multi-line
alphanumeric display which
can be programmed to show
text messages, logic-
generated prompts, alarms
and machine status. Up to
eight screens can be shown
or optionally locked out.
Count and time presets can
be made view-only or
editable. Preset entry is
achieved with simple 0-9
keys on the front panel rather
than complicated scrolling
methods. The Fusion’s real
time clock/calendar may be
displayed and/or used to time
and date stamp printouts.
With its ladder logic, the
Fusion is actually a 26 I/O
controller, making it a
complete control for many
machines and processes,
integrating the functions of
external timers, pushbuttons,
power supplies, indicating
lights, control relays and
other components in the
same box.
Features
User-configurable operator
interface with back-lit LCD
display and 18-button
tactile feedback keypad
High speed counter with
five presets and pre-warn,
totalizer, batch counter and
ratemeter
10 parameter sets
13 digital inputs
(2) 4–20 mA inputs
(2) 0–10V input
(3) Form C, 2 Form A,
2 NPN transistor, (1) 4–20
mA, and (1) 0–10V outputs
RS-232 and RS-485 serial
communications
100-line ladder logic
processor for ultimate
flexibility
Configuration software
included
NEMA 4X enclosure
V13-T1-120 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.7
Counters, Panel Meters, Tachometers and Timers
Fusion Integrated Machine Control
Features and Benefits
Standards and Certifications
UL and cUL listed
CE marked
Product Selection
Fusion Integrated Machine Control
Feature Customer Benefit
High speed count functions; including scaling, main counter,
five presets, pre-warn, totalizer, batch and rate
“Canned” count functions offer flexibility and ease of setup in the desired units
of measure.
High speed counting independent of ladder scan time Precise and repeatable output response for high performance applications.
Flexible display with selectable character sizes (large, medium,
small), run screens and ladder triggered messages
Minimizes confusion and operator errors as information can be tailored to what
they need and in their language. Maintenance/management data can be
separated. Different character sizes allow optimization of information displayed.
Machine status information can be displayed allowing operators to take action.
Simple front panel layout and keypad. Four soft keys and six
function keys can be used as inputs
Ease of use for operator. Numeric keypad allows for ease of preset and machine
parameter entry. Function keys and soft keys allow easy and quick access to
information and/or parameters needed by the operator and don’t require using
additional inputs. Eliminates cost associated with external pushbuttons and
inputs.
Parameter sets Allows for predefined recipes/jobs to be preloaded for the operator. Simplifies
operator interaction and minimizes errors.
Programmable relay logic Well understood programming method that allows flexibility in control
functionality. Easy to tailor the control to various applications.
26 I/O (digital and analog) Provides application flexibility. Analog inputs allow monitoring key process
parameters. Analog outputs allow interfacing to drives and other control
products.
Integrated solution Reduced overall control costs, installation and commissioning. More flexible
and capable than traditional count/control solutions but less complex than many
PLC solutions.
Windows® and front panel programming Ease of programming and configuration control.
RS-232 and RS-485 serial communication ports Allow for direct connection to PC for programming, connection to Modbus®
networks, interface to serial printer.
Robust type 4X package. DIN cutout and short depth
2.82 in (71.6 mm)
Suited for wet applications. Same cutout as the President Series—easing the
migration. Short depth minimizes the cost and size of the machine panel or
control enclosure.
Input power: 85–265 Vac 50/60 Hz or 10–30 Vdc models Greatly reduces models required for different control voltages.
Output power: 12 Vdc at 75 mA, 24 Vdc at 100 mA Eliminates the need for an external power supply for encoders, analog
transducers, etc.
Depluggable screw terminals Allows for ease of wiring and removal of control. Terminals are different sizes to
error-proof installation.
Non-volatile memory and capacitor backed real time clock Don’t have to worry about a battery failing down the road.
Real time clock Allows for control functions to be performed on day/time and allows for
date/time stamping on printouts.
UL, cUL and CE marked Ease of meeting machine agency requirements and robust EMC performance.
Description Catalog Number
Fusion integrated machine control—10–30 Vdc power 57550400
Fusion integrated machine control—85–265 Vac power 57551400
Fusion configuration software 57590400
57550400
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-121
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.7
Counters, Panel Meters, Tachometers and Timers
Fusion Integrated Machine Control
Technical Data and Specifications
General Specifications
Description Specification
Environmental
Operation Indoor use to 2000m
Temperature 32° to 122°F (0° to 50°C) operating
–4° to 158°F (–20° to 70°C) storage
Humidity 0 to 85% RH, non-condensing
Vibration 2.5 Gs, 30–200 Hz
Shock 30 Gs, 11 ms half sinewave
EMC EN61326:1997
All I/O lines except RS-485 <30m
Front panel Type 4X indoor use only, when mounted with gasket provided
Safety UL and cUL listed, CE compliant
Input Power
AC model 85–265 Vac, 47–63 Hz, 20 VA; isolation 2300 Vac
DC model 10–30 Vdc, 15 VA
Inputs
Control
Number 10
Impedance 4.75k ohms to +5 Vdc
Thresholds
High 3.5–30 Vdc
Low 0–1.0 Vdc
Counter
Number Three (including reset)
Impedance 4.75k ohms to +5 Vdc or 26.9k ohms to ground
Thresholds
High 3.5–30V
Low 0–1.5V, or 200 mV p-p to 50V rms at 26.9k ohms (mag pickup)
Response 140 Hz or 14 kHz for sinking, push-pull or mag pickup inputs
60 Hz or 6 kHz for sourcing only inputs
All frequencies based on 50-50 duty cycle
6 kHz maximum sustained count speed
Analog
Number 4
Type 4–20 mA and two 0–10 Vdc
Accuracy ±0.5% FS and ±200 PPM/°C
Impedance 100 ohms (current input), 1.27M ohms (voltage input)
Overrange 45 mA max. (current input), 20V max. (voltage input)
V13-T1-122 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.7
Counters, Panel Meters, Tachometers and Timers
Fusion Integrated Machine Control
General Specifications, continued
Description Specification
Outputs
Power (AC input model only) 24 Vdc ±15%, 100 mA max., short-circuit protected
12 Vdc ±10%, 75 mA max., short-circuit protected
Relays
Number 3 (Form C), 2 (Form A)
Contacts 5A, 250 Vac, 30 Vdc
Isolation 2300 Vac
Transistors
Number 2
Type NPN Darlington
Ratings 150 mA max. ON current, 30 Vdc max. OFF voltage
Analog
Number 2, short-circuit protected
Type 4–20 mA (<450 ohms), 0–10V (>2500 ohms)
Accuracy ±0.5% FS and ±200 PPM/°C
Common mode voltage rating 250 Vac
Isolation 2300 Vac
RS-232
Connector DB-9S
Polarity DCE
Baud rate 1200–19200
RS-485
Connector Six-wire RJ-12 phonejack
Baud rate 1200–19200
Data Retention
Program data
Type Non-volatile
Duration 100 years, no batteries
Real time clock
Type Capacitor
Charge time Three minutes
Retention 1–5 days
Human Interface
Display
Type 128 x 64 pixel graphic LCD with LED backlight
Figure size
0.12 in (3 mm) high, 21 characters
per line, 6 lines maximum
0.24 in (6 mm) high, 10 characters
per line, 3 lines maximum
0.35 in (9 mm) high, 7 characters per line, 2 lines maximum
Keys
Number 18
Type Membrane switches with tactile feedback
Real time clock format Seconds, minutes, hours, day and date
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-123
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.7
Counters, Panel Meters, Tachometers and Timers
Fusion Integrated Machine Control
Dimensions
Approximate Dimensions in Inches (mm)
Fusion Integrated Machine Control 1
Note
1Recommended panel cutout is 0.375 in (9.5 mm) max. panel thickness.
123
xxxx
L1 L2
2 2 2 RUN3
45678910 11121314 15151617
P/N 57551 400
01
F1
1
F2
1
F3
1
F4
4
F5
5
F6
6
123
5
5.33 (135.5)
6.18 (157) 2.50 (63.5)
2.79 (70.8)
5.433±0.039
(138±1)
3.42
(86.9)
2.57
(65.3)
2.677±0.028
(68±0.7)
0.38
(9.7)
V13-T1-124 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.8
Counters, Panel Meters, Tachometers and Timers
Special Function Controls
President Position Controller
Contents
Description Page
President Position Controller
Technical Data and Specifications . . . . . . . . . . V13-T1-125
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-127
Learn
Online
President Position Controller
Product Description
The 58868400 closed-loop
position control provides
digital output signals (run,
direction and fast/slow) to a
drive to cause a motor-driven
tool to be positioned along a
single axis. These signals can
also be used to control values
in a hydraulic positioning
system. Typically, a
quadrature encoder, coupled
to the drive mechanism,
provides the feedback signal
to the position control. Up to
five destinations can be
automatically sequenced
through in a move-and-dwell
process, or the operator can
select a single destination for
move-and-stop positioning.
Features
6-digit, LED display, 14 mm
(0.56 in) high characters
4 move registers plus
home
2 Form C relays and 5 NPN
transistor outputs
28 kHz count speed
5 dwell time settings
15 Vdc at 100 mA power
output
Manual or automatic
operation
Programmable offset,
prewarn and kerf values
Backlash compensation
Programmable high/low
limits
20 mA current loop
communications
NEMA 4X front panel
Standards and Certifications
UL Listed
Product Selection
President Position Control
Description Catalog Number
Single-axis position control 58868400
58868400
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-125
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.8
Counters, Panel Meters, Tachometers and Timers
Special Function Controls
Technical Data and Specifications
General Specifications
Description Specification
Power Input
AC operation 120/240 Vac (±10%, –20%), 47 to 63 Hz
DC operation 11 to 16 Vdc (0.7A maximum)
Power consumption 18 watts maximum
DC Power Output
Output 15 Vdc (+1, –2), 100 mA maximum
Environment
Operating temperature 32° to 130°F (0° to 55°C)
Storage temperature –40° to 160°F (–40° to 71°C)
Operating humidity 85% relative, non-condensing
Rating NEMA 4 rating when mounted with gasket provided
Control Input Response
START/STOP 1 mS
Go home input 5 mS
Load position 5 mS
Reference input 1.7 mS
Input Voltage
Count Inputs
High 10.5 to 24.5 Vdc
Low 0 to 4.5 Vdc
Control Inputs
High 3.8 to 15.0 Vdc
Low 0 to 1.2 Vdc
Input Impedances
Count inputs 6.8k ohms to +15 Vdc (2.2 mA at 0 Vdc)
Control inputs 2.2k ohms to +5 Vdc (2.3 mA at 0 Vdc)
Relay Outputs (2)
Type Form C contacts
Load voltage Up to 240 Vac or 280 Vdc
Load current 5A resistive, 1.5A at 80% PF
Transistor Outputs (5)
Type NPN open collector with surge protection
Load voltage 30 Vdc maximum
Load current 300 mA maximum
Saturation 1.5V maximum at 300 mA
Latency 150 +5 μS/1 kHz input speed ±10 μS
Communication
Type 20 mA loop (active transmit, passive receive)
Speed 110, 300 or 1200 baud
Parity Odd, even, space
Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit (110 baud uses 2 stop bits)
Load voltage 30 Vdc maximum
Load current 300 mA maximum
Saturation 1.5V maximum at 300 mA
Latency 150 +5 μS/1 kHz input speed ±10
V13-T1-126 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.8
Counters, Panel Meters, Tachometers and Timers
Special Function Controls
General Specifications, continued
Notes
1Only function 60 and the double jumper affect the maximum input speed. The scale factor does not affect the input speed.
2The maximum input frequency only on the selected quadrature operation.
3Low speed jumper installed.
Description Specification
Input Frequency 1
Quadrature selection 2
X1 3
High speed 28 kHz
Low speed 150 Hz
X2 3
High speed 14 kHz
Low speed 150 Hz
X4 3
High speed 7 kHz
Low speed 150 Hz
Position Control Features
Setpoints Four move setpoints plus one home setpoint
Range (all setpoints) –99999 to 999999
Decimal point Four positions, programmable
Dwell times Five, one for each setpoint
Dwell time range 00.01 to 99.98 seconds
Scale factor range 0.00100 to 9.999999
Accuracy 100% when the position control is operated within the specified
speeds and input voltages
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-127
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.8
Counters, Panel Meters, Tachometers and Timers
Special Function Controls
Dimensions
Approximate Dimensions in Inches (mm)
President Position Controller
1
6
2
7
3
8
4
9
5
0
+ / -
DWELL
POSITION
RUN
MOVE
DWELL
START
STOP
FUNCTION
RECALL FAST JOG+
MOVE
JOG- POSITION
HOME
ENTER
5.80
(147.3)
5.38
(137)
5.91
(150)
Panel mounting clip ts into four
square holes in side of counter.
Recommended Panel Cutout: 5.43 W x 2.68 H (137.9 x 68.1)
Gaskets
Pt. #28720-216 (Standard)
Pt. #28720-217
Panel
Note:
Spacer Kit Pt. #38820-400
1 gasket standard.
2nd gasket and
spacer optional.
Use of optional
spacer and gasket
reduces unit depth
from 5.91 (150)
to 5.38 (137.3).
Spacer
Counter
Front
Bezel
3.04
(77.2)
2.62
(66.7)
19 20
+21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
1234
K1
K1
NO C NO AC INPUTS NC C NO
K2
K2
IN1 IN2
5 6 7 8 9 101112131415161718
V13-T1-128 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.9
Counters, Panel Meters, Tachometers and Timers
Tem p e ra t u re Con t rol s
TC Series
Contents
Description Page
TC Series
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V13-T1-129
Technical Data and Specifications . . . . . . . . . . . V13-T1-129
Special Control Function Inputs . . . . . . . . . . . . . . . V13-T1-130
TC Series
Product Description
Temperature controllers for a
wide range of applications
including heat treating,
baking, packaging, furnace
control, and chillers.
Features and Benefits
Universal temperature
inputs allow user to select
from PT100 or J, K, T, E, B,
R, S, N, L thermocouples
without modification to the
unit
Advanced fuzzy modified
PID technology minimizes
overshoot/undershoot and
allows quick and accurate
responses
Fast sampling rate of up to
five times per second
ensures accuracy in fast
processes
Standard IP65 front panel
(TC48) provides protection
in wash-down and other
challenging environments
Standards and Certifications
UL recognized
CSA certified
CE marked
RoHS compliant
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-129
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.9
Counters, Panel Meters, Tachometers and Timers
Tem p e ra t u re Con t rol s
Product Selection
TC Series
Technical Data and Specifications
General Specifications
Description
Normally
Stocked Item Catalog Number
Temperature control, 24 x 48 mm, two relay out, 90–250 Vac Yes TC24411100
Temperature control, 24 x 48 mm, SSR driver/relay out, 90–250 Vac Yes TC24412100
Temperature control, 48 x 48 mm, one relay out, relay alarm, 90–250 Vac Yes TC484110101
Temperature control, 48 x 48 mm, SSR driver out, 90–250 Vac Yes TC484120001
Temperature control, 48 x 48 mm, SSR driver out, relay alarm, 90–250 Vac Yes TC484120101
Temperature control, 48 x 48 mm, analog out, relay alarm, 90–250 Vac Yes TC484130101
Temperature control, 96 x 48 mm, one relay out, relay alarm, 90–250 Vac Yes TC964110100
Temperature control, 24 x 48 mm, two relay out, 11–26 Vac/Vdc TC24511100
Temperature control, 48 x 48 mm, one relay out, relay alarm, 11–26 Vac/Vdc TC485110101
Process control, 24 x 48 mm, analog/relay out, 90–250 Vac PC24463100
Temperature control, 48 x 48 mm, analog out, relay alarm, 90–250 Vac TC24413100
Description Specification
Power
Power 90–250 Vac, 47–63 Hz, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx4)
11–26 Vac/Vdc, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx5)
Input
Resolution 18 bits
Sampling rate 5 times/second
Temperature effect ±1.5 μV/ºC for all inputs except mV input
±3.0 μV/ºC for mV input
Sensor lead resistance effect
T/C 0.2 μV/ohm
Three-wire RTD 2.6ºC/ohm of resistance difference of 2 leads
Two-wire RTD 2.6ºC/ohm of resistance sum of 2 leads
Burn-out current 200nA
Common mode rejection ratio (CMRR) 120dB
Normal mode rejection ratio (NMRR) 55dB
Sensor break detection Sensor open for TC, RTD and mV inputs, sensor short for RTD input, below 1 mA for
4–20 mA, below 0.25V for 1–5V input
Sensor break response time Within 4 seconds for TC, RTD, and mV inputs; 0.1 second for 4–20 mA and 1–5V inputs
Output
Relay rating 2A/240 Vac; 200,000 life cycles for resistive load
Pulsed voltage Source voltage 5V, current limiting resistance of 66 ohms
Linear output
Resolution 15 bits
Output regulation 0.02% for full load change
Output setting time 0.1 sec. (stable to 99.9%)
Isolation breakdown voltage 1000 Vac
Temperature effect ±0.01% of SPAN/ºC
TC964110100
TC484120001
TC24411100
V13-T1-130 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.9
Counters, Panel Meters, Tachometers and Timers
Tem p e ra t u re Con t rol s
General Specifications, continued
Special Control Function Inputs
Input Characteristics
Description Specification
Alarm
Alarm relay Form C rating; 2A/240 Vac; 200,000 life cycles for resistive load
Alarm functions Dwell timer, deviation high/low alarm, deviation band high/low alarm, PV high/low alarm
Alarm mode Normal, latching, hold, latching/hold
Dwell timer 0.1 to 4553.6 minutes
Environmental and Physical
Operating temperature 14° to 122ºF (–10° to 50ºC)
Storage temperature –40° to 140ºF (–40° to 60ºC)
Humidity 0–90% RH (non-condensing)
Altitude 2000m max.
Pollution Degree 2
Insulation resistance 20M ohms min. (at 500 Vdc)
Dielectric strength 2000 Vac, 50/60 Hz for 1 minute
Vibration resistance 10–55 Hz, 10 m/s2 for 1 minute
Moldings Flame resistant polycarbonate
Dimensions TC96 = 1.88 in (48 mm) (W) x 3.77 in (96 mm) (H) x 3.15 in (80 mm) (D)
TC48 = 1.88 in (48 mm) (W) x 1.88 in (48 mm) (H) x 4.56 in (116 mm) (D)
TC24 = 1.96 in (50 mm) (W) x 1.04 in (26.5 mm) (H) x 4.35 (110.5 mm) (D)
Type Range Accuracy at 25ºC Input Impedance
J –120º to 1000ºC (–184º to 1832ºF) ±2ºC 2.2M ohms
K –200º to 1370ºC (–328º to 2498ºF) ±2ºC 2.2M ohms
T –250º to 400ºC (–418º to 752ºF) ±2ºC 2.2M ohms
E –100º to 900ºC (–148º to 1652ºF) ±2ºC 2.2M ohms
B 0º to 1800ºC (32º to 3272ºF) ±2ºC (–200º to 1800ºC) 2.2M ohms
R 0º to 1767.8ºC (32º to 3214ºF) ±2ºC 2.2M ohms
S 0º to 1767.8ºC (32º to 3214ºF) ±2ºC 2.2M ohms
N –250º to 1300ºC (–418º to 2372ºF) ±2ºC 2.2M ohms
L 200º to 900ºC (–328º to 1652ºF) ±2ºC 2.2M ohms
PT100 (DIN) –210º to 700ºC (–346º to 1292ºF) ±0.4ºC 1.3k ohms
PT100 (JIS) –200º to 600ºC (–328º to 1112ºF) ±0.4ºC 1.3k ohms
mV –8 mV to 70 mV ±0.05% 2.2M ohms
mA –3 mA to 27 mA ±0.05% 70.5 ohms
V –1.3V to 11.5V ±0.05% 650k ohms
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-131
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Accessories and Encoders
Contents
Description Page
Accessories and Encoders
DIN Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-132
C-Face Ring Tachometer . . . . . . . . . . . . . . . . . . V13-T1-133
Magnetic Pickup Sensor and Gear . . . . . . . . . . V13-T1-134
Rotary Contactor—ES9513/ES9513RS . . . . . . . V13-T1-134
Measuring Wheels . . . . . . . . . . . . . . . . . . . . . . V13-T1-135
Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . V13-T1-135
Cube Style Shaft Encoders . . . . . . . . . . . . . . . . V13-T1-136
Heavy-Duty Shaft Encoders. . . . . . . . . . . . . . . . V13-T1-139
Right Angle, Size 20 Shaft Encoders . . . . . . . . . V13-T1-142
Accessories and Encoders
Product Overview
Eaton offers a variety of
accessories to complement
our counting and control
product offering.
Features
Easy integration with Eaton
counters
V13-T1-132 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
DIN Rail Adapter
Product Description
Allows mounting of 1/32 DIN
front panel mounted products
to DIN rail inside panel.
Features
For panel-mounting all DIN
size counters, timers and
process indicators 0.94 x
1.89 in (24 x 48 mm) or
1.97 x 0.98 in (50 x 25 mm)
Cut-out: 0.98 x 1.97 in
(25 x 50 mm)
For snap-on fitting to
35 mm top hat DIN rails
Construction
Mounting panel for
counter: Chrome-plated
sheet steel
Top hat DIN rail adapter:
Glass fiber reinforced
polymide
Product Selection
DIN Rail Adapter
Dimensions
Approximate Dimensions in Inches (mm)
DIN Rail Adapter
Description Catalog Number
DIN rail adapter for 1/32 DIN panel mount devices A2448DINADAPT
A2448DINADAPT
3.98 (101.0)
1.77
(45.0)
3.29
(83.5)
2.95
(75.0)
1.77
(45.0)
2.76
(70.0)
1.0
(25.4)
1.98 (50.4)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-133
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
C-Face Ring Tachometer
Product Description
Provides sensing of motor
speed when used with
ratemeter/tachometer.
Features
5–16 Vdc input power
NPN transistor output,
20 mA sinking capacity
60 pulses per resolution
Zero speed pickup
Variety of motor C-face
sizes: 56, 184, 254, 256
39° to 225°F (4° to 107°C)
operating temperature
Product Selection
C-Face Sensor
Description
Normally
Stocked Item Catalog Number
Motor size 56C Yes 47007056
Motor size 143TC, 145TC, 182C, 184C Yes 47007184
Motor size 184TC, 213C, 215C, 254C Yes 47007215
47007_
V13-T1-134 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Magnetic Pickup Sensor and Gear
Product Description
Sensor ideal for use with a
variety of Eaton counters to
show motor/shaft speed or
measurement.
Features
Magnetic Pickup
0.25 in (6.4 mm) diameter
Ideal for tachometer and
rate control applications
–40° to 298°F (–40° to
148°C) operating
temperature
Output is AC signal,
amplitude proportional to
speed of target
10 ft (3m) cable attached
L-mounting bracket
included
30-Tooth Gear Accessory
1.6 in (41 mm) diameter
0.275 in (7 mm) bore
diameter
Mounting set screw
included
Product Selection
Magnetic Pickup Sensor and Gear
Rotary Contactor—ES9513/ES9513RS
Product Description
Simple reed switch circuit to
provide a contact closure for
counting.
Features
No power required
Reed switch output
models for electronic
counters
Contact closure output
Leaf switch output models
for electromechanical
counters
5/16 in (7.9 mm) double
shaft, 2400 rpm max. at
1:1 ratio
12 in (304.8 mm) wire
leads
Product Selection
Rotary Contactor
Description Catalog Number
Magnetic pickup 47004400
30-tooth gear for magnetic pickup 28433400
47004400 and 28433400
Description Rotary Contactor Catalog Number
12:1 ratio reed switch output ES9513RS 39100400
10:1 ratio reed switch output ES9513RS 39100401
1:1 ratio reed switch output ES9513RS 41100400
1:3 ratio reed switch output ES9513RS 41100401
1:3.28 ratio reed switch output ES9513RS 41100402
1:10 ratio reed switch output ES9513RS 41100403
1:10 ratio leaf switch output ES9513 40892400
1:1 ratio leaf switch output ES9513 40891400
1:3 ratio leaf switch output ES9513 40892401
3910040
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-135
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Measuring Wheels
Product Description
Measuring wheel mounts to
Eaton encoders and rotary
contactor to allow for
accurate measurement.
Features
For use with shaft
encoders and rotary
contactors
12 in (304.8 mm) meter
circumference
Urethane, rubber and
knurled edges available
Product Selection
1 Ft Circumference Measuring Wheels
Mounting Bracket
Product Description
Mounting bracket for Eaton
D-Series counters and rotary
contactors.
Product Selection
Mounting Bracket
Description
Normally
Stocked Item Catalog Number
5/16 in bore, urethane rim Yes 20144300KIT
3/8 in bore, urethane rim 20144303KIT
5/16 in bore, rubber rim Yes 20154300KIT
3/8 in bore, rubber rim Yes 20154301KIT
5/16 in bore, knurled rim Yes 20156300KIT
3/8 in bore, knurled rim 20156301
Measuring Wheel
Description
Normally
Stocked Item Catalog Number
Mounting bracket Yes 40460400
Mounting Bracket
V13-T1-136 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Cube Style Shaft Encoders
Product Description
Provides accurate pulse
outputs for use with PLCs
and counters.
Features
5–28 Vdc input power
80 mA current draw
NPN transistor output,
250 mA sinking capacity
Square wave output;
(50-50 duty cycle)
Single channel and
quadrature models
Up to 600 pulses per
revolution
3/8 in (9.5 mm) double
ended shaft
ABEC three double sealed
ball bearings
Tapped holes for face or
base mounting
Military style connector
Product Selection
Cube Shaft Encoders
Accessory
Mounting Bracket 1
Note
1 40460400 is shown, 40460402 has additional mounting plate for encoders.
Description
Normally
Stocked Item Catalog Number
Single Channel
60 pulses per revolution 38150060
100 pulses per revolution Yes 38150100
120 pulses per revolution 38150120
600 pulses per revolution Yes 38150600
Quadrature
60 pulses per revolution 38151060
100 pulses per revolution Yes 38151100
120 pulses per revolution 38151120
600 pulses per revolution Yes 38151600
Description
Normally
Stocked Item Catalog Number
Mounting bracket 40460402
Cube Shaft Encoder
Mounting Bracket
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-137
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Technical Data and Specifications
General Specifications
Description Specification
Electrical
Input (38150)
Voltage 9 to 16 Vdc
Current 60 mA max. at 16 Vdc
Ripple 2%
Input (38151)
Voltage 5 to 28 Vdc
Current 60 mA nom., 100 mA max.
Ripple <2%
Output
Type Current sinking transistor with 1.5k ohms pull-up
Sinking current 100 mA max.
Max. voltage at 100 mA 1.3 Vdc
Blocking voltage 40 Vdc max.
Polarity Positive
Wave shape Square wave
Pulse rate
38150 1 to 20,000 pulse per second
38151 1 to 10,000 pulse per second
Rise time <1 μS
Pulses per rev. 1 to 1270
Accuracy Within ±0.1°
Environmental
Operating temperature 32° to 167°F (0° to 75°C)
Vibration 3 Gs at 5 to 1000 cps
Shock 20 Gs, 10 ms
Mechanical
Shaft speed 6000 RPM max.
Shaft rotation CW or CCW
Bearings Sealed ball bearings
Starting torque 0.1 oz-in
Moment of inertia 0.0025 ounce in-sec2
Radial loading 40 pounds operating
Axial loading 30 pounds operating
Shaft 3/8 in (9.5 mm) dia.
Operating life Up to 100,000 hours, depending on speed
Housing Aluminum with black anodized finish. Sealed against dust, oil, vapor and moisture.
Mounting Bottom or front face
Weight 1 lb (0.5 kg) max.
Connector MS-3102E-14S-6P
Mating connector MS-3106A-14S-6S
with 10 ft (3m) shielded cable and termination for electronic controls
V13-T1-138 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Dimensions
Approximate Dimensions in Inches (mm)
Cube Shaft Encoders
0.70
(17.8)
0.50
(12.7)
0.33
(8.3)
0.38
(9.5)
2.25
(57.2) (4) 6.32 (160.5) Tapped Holes
0.25 (6.4) Deep on 2.00 (50.8) B.C.
(4) 6.32 (160.5) Tapped Holes
0.25 (6.4) Deep on 2.00 (50.8) B.C.
(Same Mtg. Holes on
Opposite End and Bottom)
0.25
(6.4)
0.06
(1.6)
2.25
(57.2)
45°
2.25
(57.2)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-139
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Heavy-Duty Shaft Encoders
Product Description
Provides accurate pulse
outputs for use with PLCs
and counters.
Features
5–28 Vdc input power
80 mA current draw
NPN transistor output,
250 mA sinking capacity
Square wave output
Single channel and
quadrature models
3/8 in (9.5 mm) single
ended shaft
ABEC 3 double sealed ball
bearings
Tapped holes for face or
base mounting
Military style connector
Product Selection
Heavy-Duty Encoder
Description
Normally
Stocked Item Catalog Number
Single Channel
60 pulses per revolution Yes 48370060
100 pulses per revolution 48370100
120 pulses per revolution Yes 48370120
600 pulses per revolution Yes 48370600
Quadrature
60 pulses per revolution Yes 48371060
100 pulses per revolution Yes 48371100
100 pulses per revolution Yes 48371120
600 pulses per revolution Yes 48371600
Heavy-Duty Shaft
Encoder
V13-T1-140 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Technical Data and Specifications
General Specifications
Description Specification
Electrical
Input
Voltage 5 to 28 Vdc
Current 60 mA nom., 100 mA max.
Ripple –2%
Output
Type Current sinking transistor with 1.5k ohms pull-up
Sinking current 100 mA max.
Max. voltage at 100 mA 1.3 Vdc
Blocking voltage 40 Vdc max.
Polarity Positive
Wave shape Square wave (50-50 duty)
Pulse rate 0 to 20,000 pulse per second
Rise time <1 μS
Pulses per rev. 1 to 1270
Accuracy Within ± 0.1° or 6 arc minutes
Environmental
Operating temperature 32° to 167°F (0° to 75°C)
Vibration 3 Gs at 58 to 500 cps
Shock 50 Gs, 11 ms duration
Mechanical
Shaft speed 6000 RPM max.
Shaft rotation CW or CCW
Bearings Sealed ball bearings
Starting torque 1.0 oz-in
Radial loading 50 pounds operating
Axial loading 35 pounds operating
Shaft 3/8 in (9.5 mm) dia.
Housing Aluminum with black painted finish. Sealed against dust, oil, vapor and moisture.
Mounting Provisions for bottom or front face
Weight 3.25 lbs (1.47 kg) max.
Connector MS-3102E-14S-6P
Mating connector
MS-3106A-14S-6S
with 10 ft (3m) shielded cable and termination for electronic controls
(Part No. 29665-300)
Connector, clamp and bushing only (Part No. 29729-300)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-141
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Dimensions
Approximate Dimensions in Inches (mm)
Heavy-Duty Encoder
0.70
(17.8) 0.81
(20.6)
1.50
(38.1)
6.00
(152.4)
1.18
(30.0)
1.50
(38.1)
1.13
(28.6)
Dia. 0.38 (9.5)
Shaft
with Flat 2.00 (50.8) Bolt Hole CircleMounting Holes (Typical)
1/4-20, 0.55 (14.0) Deep
on 2.00 (50.8) B.C.
3.00
(76.2)
0.06
(1.6)
3.00
(76.2)
45°
3.00
(76.2)
1.50
(38.1)
1.50
(38.1)
V13-T1-142 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Right Angle, Size 20 Shaft Encoders
Product Description
Provides accurate pulse
outputs for use with PLCs
and counters.
Features
5–28 Vdc input power
100 mA current draw
NPN transistor output,
100 mA sinking capacity
Quadrature output, two
square waves
Up to 1800 pulses per
revolution
Flange mounting
3/8 in (9.5 mm) shaft
diameter
Double shielded ball
bearings
Military style connector
Product Selection
Right-Angle Shaft Encoder, Size 20
Encoder Cables
Description Catalog Number
100 pulses per revolution 38159100
120 pulses per revolution 38159120
600 pulses per revolution 38159600
1000 pulses per revolution 381591000
1800 pulses per revolution 381591800
38159_
Description Catalog Number
10 ft encoder cable 29665300
15 ft encoder cable 29665315
20 ft encoder cable 29665320
25 ft encoder cable 29665325
30 ft encoder cable 29665330
35 ft encoder cable 29665335
40 ft encoder cable 29665340
50 ft encoder cable 29665350
75 ft encoder cable 29665375
100 ft encoder cable 29665400
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-143
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Technical Data and Specifications
General Specifications
Description Specification
Electrical
Input
Voltage 5 to 28 Vdc (4.75 min., 28.0 max.)
Current 100 mA max. with no output load
Ripple –2% peak to peak at 5 Vdc
Output
Type Quadrature current sinking transistors with 2.2k ohms pull-up
Sinking current 100 mA max.
Max. voltage at 100 mA 1.3 Vdc
Blocking voltage 40 Vdc max.
Polarity Positive
Wave shape Square wave (50-50 duty cycle)
Pulse rate 0 to 100,000 pulses per second
Noise immunity Tested to BS EN6100-4-2; IEC801-3; BS EN61000-4-4; DDENV 50141; DDENV 50204;
BS EN55022 (with European compliance option)
Symmetry 180 electrical degrees ±18
Quadrature phasing 90 electrical degrees ±36
Minimum edge separation 54 electrical degrees
Rise time <1 μS
Pulses per rev. 1 to 1270
Accuracy Within ±0.1°
Environmental
Operating temperature 32° to 158°F (0° to 70°C)
Vibration 20 Gs at 50 to 500 cps
Shock 75 Gs, 11 ms
Mechanical
Shaft speed 8000 RPM max.
Shaft rotation CW or CCW
Bearings Double shielded ball bearings
Starting torque 1.0 oz-in typical
Moment of inertia 5.2 x 104 ounce in-sec2
Radial and axial loading (80 lbs max.) 20–40 lbs for bearing life of 1.5 x 109 revolutions
Maximum acceleration 1 x 105 radians/second2
Shaft 0.375 in (9.5 mm) dia.
Housing Black non-corrosive finish. Sealed against dust, oil, vapor and moisture.
Mounting Flange mount
Weight 11 oz (312g)
Connector MS-3102E-14S-6P
Mating connector
MS-3106A-14S-6S
with 10 ft (3m) shielded cable and termination for electronic controls
(Part No. 29665-300)
Connector, clamp and bushing only (Part No. 29729-300)
V13-T1-144 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.10
Counters, Panel Meters, Tachometers and Timers
Accessories and Encoders
Dimensions
Approximate Dimensions in Inches (mm)
Right-Angle Shaft Encoder
2.06
(52.3)
1.41
(35.9)
1.18
(30)
6-32 UNC
0.25 (6.4) Deep 4 x 90°
Dia. 2.0 (50.8) B.C.
Dia. 0.16 (4.0)
Through 4 x 90°
Dia. 2.48 (62.9) B.C.
0.05
(1.3) 0.05
(1.3)
0.30
(7.6) 2.0
(50.8)
0.60
(15.2)
2.0
(50.8)
0.80
(20.3)
0.75
(19.1)
Shaft Size
3/8" 0.3745 (9.512)
0.63
(15.9)
0.87
(22.1)
Side Mount
MS Style
Connector
1.75
(44.5)
2.06
(52.3)
Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-145
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.11
Counters, Panel Meters, Tachometers and Timers
Accessories
Spare Parts
General Accessories
Fusion
Ambassador Family Accessories
President
Note
1Call EatonCare.
Style Number Description
36172202KIT Front panel gasket
48369200KIT Mounting clip
28748200KIT Screw for mounting clip
48355110KIT Terminal strip—10 position
48355112KIT Terminal strip—12 position
58802420 Desk kit for President Series (part numbers 5882–5886 and 5782)
29729300 Accessories connector
56460400 Sequence control
57044200KIT 6460 keypad
57740290KIT Mounting clip
46066220KIT Gasket
48720623KIT Ambassador front keypad
28720400KIT Kit mounting Ambassador Series
48720614KIT Label position control
48720280KIT Label membrane switch, Ambassador
Style Number Description
48160400 Input signal conditioner
48160440 Timer module (selectable time base oscillator)
48160451 Analog to frequency converter
499904xx(08/16) Simultaneous input processor (anti-coincidence counting from multiple input devices) 8 inputs/16 inputs
38091400 RC surge suppressor
3605945x(0/1) Solid-state I/O modules (AC input and output, DC input and output) 0 = DC, 1= AC
36059201 Plug-in-module, 10–32 Vdc or 15–32 Vac input
36059202 Plug-in-module, 12–140 Vac output
Style Number Description
47590200 Front overlay label
Style Number Description
48183401 Desk mount kit (enclosure for flat surface mounting)
58801460 RS-485 to RS-232 communications converter
58801461 RS-485 to RS-232 communications converter (Europe)
38145400 RS-485 interconnect kit
38146xxxx RS-485 cable—xxxx is length in feet, specify with 4 digits (0500 = 500 ft) 1
Style Number Description
28720302KIT Mounting kit
28720301KIT Kit mounting clip and gasket
48720410 5881-0 President replace label
48720420 Label kit
48720430 Kit label replace Lexan to Mylar
48720440 5884 President replace label
48720450 5885 President replace label
48720460 5886 President replace label