Counters, Panel Meters, Tachometers and Timers CS Series Stroke Counter 1.1 Totalizers Mechanical Totalizers (Stroke) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Totalizers (Revolution) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical Totalizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 V13-T1-14 V13-T1-29 V13-T1-41 V13-T1-53 V13-T1-55 V13-T1-57 V13-T1-60 V13-T1-64 V13-T1-69 V13-T1-72 V13-T1-76 Hour Meter 1.3 Tachometers/Ratemeters Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ambassador Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 Fusion Integrated Machine Control 1.5 V13-T1-111 V13-T1-114 V13-T1-119 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-124 V13-T1-128 1 1 1 V13-T1-132 V13-T1-133 V13-T1-134 V13-T1-134 V13-T1-135 V13-T1-135 V13-T1-136 1 1 1 1 1 Accessories Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 Accessories and Encoders DIN Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-Face Ring Tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Magnetic Pickup Sensor and Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotary Contactor--ES9513/ES9513RS . . . . . . . . . . . . . . . . . . . . . . . . Measuring Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shaft Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.11 V13-T1-99 V13-T1-105 Temperature Controls TC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 V13-T1-91 Special Function Controls President Position Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9 V13-T1-89 Fusion Integrated Machine Control Fusion Integrated Machine Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8 V13-T1-85 Flow Totalizers, Transmitters and Controls Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7 V13-T1-82 Timers/Hour Meters Electronic Timers/Hour Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical Timers/Hour Meters . . . . . . . . . . . . . . . . . . . . . . . Hour Meter/Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.6 V13-T1-80 Digital Panel Meters E5-324-E Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 Count Controls/Preset Counters/Totalizers 1/16 DIN Battery Powered LCD Count Control . . . . . . . . . . . . . . . . . . . 1/16 DIN LCD Preset Counters with Rate and Time. . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . President Series (Totalizers) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . President Series (Count Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ambassador Series (Totalizers) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ambassador Series (Count Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . PD-Q and PD-ER Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eclipse Series Panel Meter V13-T1-5 V13-T1-145 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-1 1.1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Contents Totalizers Description 1 Page Totalizers Product Selection Guide . . . . . . . . . . . . . . . . . Mechanical Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical . . . . . . . . . . . . . . . . . . . . . . Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 Learn Online 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Product Overview Totalizers are used in a wide variety of applications where accurate totals are needed. Typical applications include counting the number of parts produced, amount of material used, or the number of machine cycles occurring. Totalizers are the simplest and most common type of counter. As an added bonus, some models can perform both totalizing and ratemeter functions. Application Example Limit Switch Finished Parts Limit Switch Manufacturing Process Typical Application Parts are fed into a machine or process, an operation is performed, and the finished parts exit the machine or process. The subtract totalizer is used to indicate the number of parts in process. Raw Parts 1 1 1 1 1 1 1 1 V13-T1-2 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-3 V13-T1-5 V13-T1-14 V13-T1-29 V13-T1-41 Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Product Selection Guide 1 1 Totalizers Mechanical Characteristics Typical Applications Various size ranges for different duty cycles and environments Winding and spooling equipment No power supply needed Mechanical piece/cycle counting Position display Panel Cutout in Inches (mm) Various mounting configurations Page V13-T1-5 1 1 1 Long life and always readable display 1 Electromechanical Various price, voltage and size ranges for different duty cycles and environments Coin-operated equipment Long life and always readable display Printing presses Gaming machines Various mounting configurations V13-T1-29 1 1 1 Secondary machines (e.g. punch press) 1 E5-024-C Non-replaceable battery (min. eight-year life) Replacement for mechanical counters Compact, low cost and high efficiency Transaction counting Eight-digit LCD totalizers Parts counting Manual or electrical reset Position indication or measurement 0.870 x 1.772 (22 x 45) V13-T1-42 1 1 Various counting modes/inputs E5-_24-E Compact device with bright, LED display Multiple functions available: count, time, rate, multifunction, double-function Count, measure, time where small package and easy-to-read display required 0.870 x 1.772 (22 x 45) V13-T1-44 Motor/pulley RPM Replaceable lithium battery Eight-digit, high-visibility LCD display Portable/mobile/remote flow monitoring (e.g. sewer pumping, pesticide application) Optional backlighting Position display, RPM Various input options available Length measurement (e.g. carpet, cable) Economical, multifunction display Large, easy-to-read display Large, LED characters Position display AC or DC power options Motor/pulley RPM 1 1 Position display 24 Vdc Power 1 1 Courier E5-496-E 1.299 x 2.677 (33 x 68) V13-T1-46 1 1 1.772 x 3.780 (45 x 96) V13-T1-49 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-3 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Totalizers, continued 1 Characteristics Typical Applications Bright LED display with 14 mm characters Cut-to-length machinery with batching Simple configuration with 14-button tactile keypad Parts batching/palletizing Many different versions fit almost any application Die press positioning control President 1 1 1 Panel Cutout in Inches (mm) Page 2.667 x 5.433 (68 x 138) V13-T1-60 2.667 x 2.667 (68 x 68) V13-T1-69 1.988 (50.5) dia. or DIN rail V13-T1-111 Applications where parameter changes are required Ambassador Eight-digit, high-visibility, two-line LCD display User-configurable control inputs 1 Flow control where simultaneous total and rate display are required Highly flexible control/display Cut-to-length and other simple processes where flexibility of inputs/outputs required Combination counter consists of time meter and adding counter in one General counting 1 1 Hour Meter/Counter High shock resistance Service interval for measurement systems (respiratory ventilators, oxygen machines, dialysis machines) Magnified figures Small appliances Protection IP52 (front) UV lamps Data retention if power is lost Display panels in cars Without reset 1 1 1 Long service life UL approved 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-4 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Contents Mechanical Totalizers (Stroke) Description Mechanical Totalizers (Stroke) X Series/Pushbutton Desk Tally . . . . . . . . . . . . CS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Totalizers (Revolution) . . . . . . . . . . . . . Electromechanical Totalizers . . . . . . . . . . . . . . . . . Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . Page V13-T1-6 V13-T1-8 V13-T1-10 V13-T1-12 V13-T1-14 V13-T1-29 V13-T1-41 1 1 1 1 1 1 1 1 1 1 1 Mechanical Totalizers (Stroke) Product Overview Features Eaton's mechanical totalizers are available in a variety of heavy-duty configurations for applications when power is unavailable. 1 Variety of reset methods available Accurate counting without need for power 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-5 1.1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers X Series/Pushbutton Desk Tally Product Description X Series Counters Model X Series is a dustproof and rustproof series of counters for light and medium-duty work. They are sound and durable, requiring a minimum of driving effort, and have been especially designed for incorporation as integral parts of a variety of machines and equipment. Pushbutton Desk Tally Ruggedly constructed counters with feather-touch pushbutton operation and maximum readability. Specifications and dimensions are basically the same as the X Series counters. Will give long and accurate service in areas requiring hand counting or during hand operations. Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model X Series Stroke Counters and Pushbutton Desk Tallies, consider: X Series Stroke Counter Number of figures Drive X Series Stroke Counters and Pushbutton Desk Tallies No. of Figures Drive Reset Mounting Catalog Number Order Number 1 5 LH lever Knob Base 5-X-1-1-L 40272401 1 4 RH lever Knob Base 4-X-1-1-R 40263401 5 RH lever Knob Base 5-X-1-1-R 40272402 5 LH lever Knob Base 5-X-1-1-L-REV 1 40272400 1 5 RH lever Knob Base 5-X-1-1-R-REV 1 40272403 4 Push bar Knob Base 4-X-2 21619400 1 4 Pushbutton Knob Base 4-X-2-A 33245400 1 Pushbutton Desk Tally 1 1 1 Note 1 Reverse stroke. 1 1 1 1 1 1 1 1 V13-T1-6 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 4 or 5 Speed 1000 cpm Shaft 0.125 in (3.2 mm) diameter stainless steel Drive Drive parts of nylon Bearings Oil-less, maintenance free Finish Black frame and Cycolac black cover Stroke operation 33 minimum; 58 maximum 1 Figure size 3/16 in (4.8 mm) high, white-on-black background Reset Knob 1 1 1 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 X Series C 0.14 (3.6) Pre Stroke 0.97 1.20 1.44 (24.6) (30.6) (36.5) 0.12 (3.2) 0.53 (13.5) 1 1 12 5 45 5 0.44 (11.1) A B 1 0.89 (22.6) 1.38 (35.1) D 58 5 1 Dia. 0.093 (2.36) Index Stroke 1 Total Stroke Model A B C D 4-X-1-1_ 1.86 (47.2) 2.76 (70.2) 0.62 (15.7) 0.89 (22.6) 5-X-1-1_ 2.16 (54.8) 3.06 (77.8) 0.81 (20.6) 0.95 (24.1) 1 1 1 1 Note 1 Operating stroke angles apply to forward stroke counter only. Check factory for angles of reverse stroke counter. 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-7 1.1 1 1 1 1 1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers CS Series Product Description Model CS Series of small, compact, top reading stroke counters is designed for use in most industrial applications. These counters are ruggedly built and feature a single casting case, which assures great rigidity and a tight seal for working parts. Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model CS Series Stroke Counters, consider: CS Series Stroke Counter 1 1 Number of figures Drive lever CS Series Stroke Counters No. of Figures Drive Reset Mounting Catalog Number Order Number 5 RH lever Wing nut Base 5-CS-1-1-R 31062401 5 RH lever Wing nut Base 5-CS-1-1-R-RP 1 01464400 1 1 1 1 1 Technical Data and Specifications General Specifications Description Specification Figures 4 or 5 Speed 600 cpm Stroke operation 37-1/2 minimum; 75 maximum 1 Shaft 0.25 in (6.4 mm) diameter stainless steel, rustproof 1 Drive Accurately machined, hardened steel parts Bearings Oil-less, maintenance free 1 Figure size 11/32 in (8.7 mm) high, black-on-white background Reset Contoured wing nut 1 Finish Black frame Operating lever Cast zinc. Adjustable to any position. Furnished complete with pull spring. 1 1 Note 1 Special feature: rustproof. 1 1 1 1 1 V13-T1-8 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Dimensions Approximate Dimensions in Inches (mm) 1 CS Series 1 1 Dia. 0.156 4 Mtg. Holes 0.47 (11.9) 1 0.73 (18.6) D 0.42 (10.7) 1 1 Stroke 37.5 Min. - 75 Max. 0.50 (12.7) 0.92 (23.4) 1 1 1.25 (31.8) 1.34 (34.1) Dia. 0.25 (6.35) 1.19 (30.2) A B C 0.56 (14.3) 1 2.09 (53.1) 1 1 0.22 (5.6) 1.25 (31.8) 1.69 (42.9) 1.00 (25.4) 1 1 Model A B C D 4-CS-1_ 3.12 (79.2) 3.50 (88.9) 4.03 (102.3) 1.87 (47.6) 5-CS-1_ 3.62 (91.9) 4.00 (101.6) 4.53 (115.0) 2.38 (60.5) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-9 1.1 1 1 1 1 1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers H Series Product Description Model H Series heavy-duty counters are designed for hard usage and long, troublefree service. They are high speed, streamlined counters constructed of the highest quality materials and drive shaft moves in oil-less bearings. All shafts are stainless steel. The drive action is designed with overstroke so counter does not bottom, increasing life and permitting easier installation. The sturdy cover is stamped steel, locked into position on a heavy, die-cast base of a special alloy. A heavy steel mounting plate is adjustable for either bottom or back mounting. Model "H" has earned the reputation of being the "work horse" of industrial counters. Wing nut or tamper-proof reset lock which requires a key to reset the counter, guarding against unauthorized resetting or tampering. Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model H Series Stroke Counters, consider: H Series Stroke Counter 1 1 1 Number of figures Drive lever location (left or right side) Type of reset (lock or wing nut) H Series Stroke Counters No. of Figures Drive 5 5 5 Order Number Reset Mounting Catalog Number RH lever Wing nut Base 5-H-1-1-R 40205400 LH lever Wing nut Base 5-H-1-1-L 40205401 RH lever Wing nut Base 5-H-1-1-R-REV 1 00597400 1 00598400 5 LH lever Wing nut Base 5-H-1-1-L-REV 1 5 RH lever Wing nut Base 5-H-1-1-R-RP 2 5 LH lever Wing nut Base 5-H-1-1-L-RP 2 40205405 1 5 RH lever Lock reset Base 5-H-1-2-R 40206404 5 LH lever Lock reset Base 5-H-1-2-L 40206405 1 5 RH lever Lock reset Base 5-H-1-2-R-RP 2 40206400 1 5 RH lever Wing nut Rear 5-H-1-4-R 00507400 5 RH trip arm Wing nut Base 5-H-5-A 31049400 40205404 1 5 RH trip arm Wing nut Base 5-H-5-B 31049401 5 LH trip arm Wing nut Base 5-H-5-C 31049402 1 5 LH trip arm Wing nut Base 5-H-5-D 31049403 1 5 RH trip arm Lock reset Base 5-H-6-A 01533400 5 RH trip arm Lock reset Base 5-H-6-B 01534400 5 LH trip arm Lock reset Base 5-H-6-C 01535400 5 LH trip arm Lock reset Base 5-H-6-D 01536400 1 1 Notes 1 Special feature: Reverse stroke. 2 Special feature: Rustproof. 1 1 1 1 1 1 V13-T1-10 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Technical Data and Specifications 1 Direction Location for 5H5 and 5H6 1 1 C A 1 B 1 D 1 1 General Specifications Description Specification Figures 5 Speed 800 cpm 1 1 Stroke operation 37 stroke to count; 60 maximum stroke Shaft 0.31 in (7.9 mm) diameter stainless steel, rustproof Drive Accurately machined, hardened steel parts; Geneva drive for extra long life Bearings Oil-less, maintenance free 1 1 1 Figure sizes 11/32 in (8.7 mm) high, black-on-white background Reset Wing nut or tumbler lock reset Finish Black frame and cover Operating lever Adjustable to any position. Furnished complete with pull spring for attaching. 1 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 H Series 1 Lock Reset 1.20 (30.6) 0.98 (25.0) C 0.75 (19.1) 2.76 (70.1) 1 1 1.0 (25.4) 1.80 (45.7) 1 0.91 (23.0) Dia. 0.31 (7.92) A 1 0.75 (19.1) B 1.12 (28.4) 1 2.25 (57.2) 1 Model A B C Five figure units 3.95 (100.4) 4.38 (111.3) 2.75 (69.9) 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-11 1.1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers D Series Product Description Model D Series are mediumduty stroke counters available with 4, 5 or 6 figures that have been designed for general service on small production machines. Although compact, "D" models are sturdily constructed and thoroughly tested for accuracy and efficient operation. 1 1 Product Selection 1 When Ordering Specify To determine a model number from the Product Selection table for Model D Series Stroke Counters, consider: 1 1 1 D Series Stroke Counter Number of figures Drive lever D Series Stroke Counters No. of Figures Drive Reset Mounting Catalog Number Order Number 1 4 RH lever Wing nut Base 4-D-1-1-R 34269401 5 RH lever Wing nut Base 5-D-1-1-R 34269402 1 6 RH lever Wing nut Base 6-D-1-1-R 34269403 1 4 LH lever Wing nut Base 4-D-1-1-L 34269405 5 LH lever Wing nut Base 5-D-1-1-L 34269406 1 1 1 1 Technical Data and Specifications General Specifications 1 Description Specification Figures 4, 5 and 6 1 Speed 400 cpm Shaft 0.25 in (6.4 mm) diameter stainless steel, rustproof 1 Drive Nylon rachet and Delrin drive plate. Right-hand drive standard; left-hand drive available 1 Bearings Oil-less, maintenance free Figure size 1/4 in (6.4 mm) high, black-on-white background 1 Reset Wing nut Finish Black frame and cover 1 Operating lever Adjustable to any position. Furnished complete with pull string 1 1 1 1 1 1 1 V13-T1-12 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Dimensions Approximate Dimensions in Inches (mm) 1 D Series 1 C 1 0.62 (15.7) 1.72 (43.6) 0.50 (12.7) Dia. 0.12 (3.05) 4 Mtg. Holes 1 1.25 (31.8) 1 1 A 1.62 (41.3) B 1.87 (47.6) Model A B C 4-D-1-1_ 1.59 (40.4) 2.20 (55.9) 1.20 (30.6) 5-D-1-1_ 1.92 (48.8) 2.53 (64.3) 1.51 (38.5) 6-D-1-1_ 2.26 (57.5) 2.87 (73.0) 1.83 (46.4) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-13 1.1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Contents Mechanical Totalizers (Revolution) Description 1 Mechanical Totalizers (Stroke) . . . . . . . . . . . . . . . . Mechanical Totalizers (Revolution) X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDW Series . . . . . . . . . . . . . . . . . . . . . . . . . . . T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical Totalizers . . . . . . . . . . . . . . . . . Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 1 1 1 1 1 Mechanical Totalizers (Revolution) 1 Product Overview Features Eaton's mechanical totalizers are available in a variety of heavy-duty configurations for applications when power is unavailable. 1 1 1 Variety of reset configurations available Accurate length measurement for application where power is not available 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-14 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Page V13-T1-5 V13-T1-15 V13-T1-17 V13-T1-19 V13-T1-21 V13-T1-23 V13-T1-25 V13-T1-27 V13-T1-29 V13-T1-41 Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 X Series 1 Product Description Model X Series are dust- and rust-proof counters designed for small, medium-duty units, accurate, durable and require a minimum of driving effort. 1 They are especially designed for incorporation as integral parts of a variety of equipment that gets severe usage under adverse climatic conditions. 1 1 1 Product Selection 1 When Ordering Specify To determine a model number from the Product Selection table for Model X Series Revolution Counters, consider: X Series Revolution Counter Number of figures Ratio Drive shaft location Shaft rotation direction 1 1 1 X Series Revolution Counters No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 4 LH Clockwise 1 Knob Base 4-X-7-1-L-CL 40270406 4 LH Anti-clockwise 2 Knob Base 4-X-7-1-L-AC 40270404 4 RH Clockwise 3 Knob Base 4-X-7-1-R-CL 40270407 4 RH Anti-clockwise 4 Knob Base 4-X-7-1-R-AC 40270405 5 RH Anti-clockwise 4 Knob Base 5-X-7-1-R-AC 40275406 4 LH Clockwise 1 Knob Base 4-X-7-1-L-CL 5 40270402 5 LH Clockwise 1 Knob Base 5-X-7-1-L-CL 5 40275402 4 LH Anti-clockwise 2 Knob Base 4-X-7-1-L-AC 5 40270400 5 LH Anti-clockwise 2 Knob Base 5-X-7-1-L-AC 5 40275400 4 RH Clockwise 3 Knob Base 4-X-7-1-R-CL 5 40270403 5 RH Clockwise 3 Knob Base 5-X-7-1-R-CL 5 40275403 4 RH Anti-clockwise 4 Knob Base 4-X-7-1-R-AC 5 40270401 5 RH Anti-clockwise 4 Knob Base 5-X-7-1-R-AC 5 40275401 1 1 1 1 1 1 1 1 1 1 Top View--Left-Hand Drive 1 2 1 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Top View--Right-Hand Drive 1 4 3 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 2 3 4 5 1 Top view--left-hand drive with clockwise shaft rotation. Top view--left-hand drive with anti-clockwise shaft rotation. Top view--right-hand drive with clockwise shaft rotation. Top view--right-hand drive with anti-clockwise shaft rotation. Special feature: 10:1 ratio. 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-15 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications 1 1 1 1 1 Description Specification Figures 4 or 5 Speed 1000 cpm in 1:1 ratio; 10,000 cpm in 10:1 ratio for intermittent duty Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio 1:1 and 10:1 standard in 4-X-7 models 10:1 standard in 5-X-7 models Shaft 0.125 in (3.2 mm) diameter stainless steel; standard length 0.44 in (11.1 mm) Bearings Oil-less, maintenance free 1 Figure size 3/16 in (4.8 mm) high, white-on-black background Reset Knob 1 Finish Black frame, Cycolac black cover Drive Right- or left-hand drive; drive parts of Delrin Ratio information 1:1 is one count to each revolution of drive shaft, 10:1 is ten counts to each revolution 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) X Series 1 D C E Dia. 0.12 (3.2) 1.38 (35.1) 0.14 (3.6) 1 1.20 (30.6) 1.44 (36.5) CL 0.97 (24.6) 0.12 (3.2) AC 1 1 0.53 (13.5) 1 0.45 (11.5) 0.44 (11.1) A B 1 1 Model 1 4-X-7-1_ 1.86 (47.2) 2.76 (70.2) 0.62 (15.7) 0.19 (4.8) 0.89 (22.6) 5-X-7-1_ 2.16 (54.8) 3.06 (77.8) 0.81 (20.6) 0.25 (6.4) 0.95 (24.1) A B C D E 1 1 1 1 1 1 1 1 1 V13-T1-16 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 CS Series 1 Product Description 1 This provides greater rigidity, tighter seal of working parts and more streamlined contour. The unit is compact, rugged and features a flush mounted window to assure greater visibility. Model CS Series top reading revolution counters are designed for use in most industrial applications. The entire case is a single casting. 1 1 1 1 Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model CS Series Revolution Counters, consider: CS Series Revolution Counter 1 Number of figures Ratio Drive shaft location Shaft rotation direction 1 1 1 CS Series Revolution Counters No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 1 5 RH Clockwise 1 Wing nut Base 5-CS-7-1-R-CL 31060409 5 RH Anti-clockwise 2 Wing nut Base 5-CS-7-1-R-AC 31060411 1 5 LH Clockwise Wing nut Base 5-CS-7-1-L-CL 3 00440400 Wing nut Base 4-CS-7-1-R-CL 3 31057401 Base 4-CS-7-1-R-AC 3 31057403 1 4 RH Clockwise 4 RH Anti-clockwise 2 Wing nut 5 RH Anti-clockwise 2 Wing nut Base 5-CS-7-1-R-AC 3 00443400 4 RH and LH Clockwise 4 None Base 4-CS-7-3-CL 5 31057408 4 RH and LH Anti-clockwise 6 None Base 4-CS-7-3-AC 5 31057409 1 1 1 1 1 Top View--Right-Hand Drive 1 1 2 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Top View--Right- and Left-Hand Drive 1 6 4 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 2 3 4 5 6 1 Top view--right-hand drive with clockwise shaft rotation. Top view--right-hand drive with anti-clockwise shaft rotation. Special feature: 10:1 ratio. Top view--right- and left-hand drive with clockwise shaft rotation. Special feature: 10:1 ratio, non-reset, double shaft. Top view--right- and left-hand drive with anti-clockwise shaft rotation. 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-17 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 4 or 5 1 Speed 600 cpm in 1:1 ratio Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter 1 Ratio 1:1 standard Shaft 0.25 in (6.4 mm) diameter stainless steel; standard length 1 in (25.4 mm) 1 Drive Spur gear 1 Bearings Oil-less, maintenance free Figure size 11/32 in (8.7 mm) high, black-on-white background Reset Contoured wing nut Finish Black frame 1 1 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) CS Series Dia. 0.156 (3.96) 4 Mtg. Holes D 0.73 (18.6) 0.42 (10.7) 1 1 0.50 (12.7) 0.92 (23.4) 1 1 Dia. 0.25 (6.4) 1 2.09 (53.1) 1.34 (34.1) 1 A B C 1 1 1.19 (30.2) 0.22 (5.6) 1.00 (25.4) 1.25 (31.8) 1.69 (42.9) 0.56 (14.3) 1 Model A 1 4-CS-7_ 3.12 (79.2) 3.50 (88.9) 4.03 (102.3) 1.89 (47.9) 5-CS-7_ 3.62 (91.9) 4.00 (101.6) 4.53 (115.0) 2.38 (60.5) B C D 1 1 1 1 1 1 1 V13-T1-18 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 D-7 Series 1 Product Description 1 recommended for braiding machines, low-speed coil winders, wire measuring equipment and all mediumduty revolution applications. Model D-7 Series spur gear end drive units are compact counters that meet a variety of needs. Accurate, dependable and moderately priced, they are especially 1 1 1 1 Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model D-7 Series Revolution Counters, consider: D-7 Series Revolution Counter 1 Number of figures Shaft drive Shaft rotation direction Reset or non-reset 1 1 1 D-7 Series Revolution Counters No. of Figures Catalog Number Order Number Drive Rotation Reset Mounting 5 LH Clockwise 1 Wing nut Base 1 5-D-7-1-L-CL 31127408 5 LH Anti-clockwise 2 Wing nut Base 5-D-7-1-L-AC 31127405 1 5 RH Clockwise 3 Wing nut Base 5-D-7-1-R-CL 31127431 5 RH Anti-clockwise 4 Wing nut Base 5-D-7-1-R-AC 31127400 5 LH Anti-clockwise 2 None Base 5-D-7-3-L-AC 31127412 5 RH Clockwise 3 None Base 5-D-7-3-R-CL 31127438 1 1 1 1 Top View--Left-Hand Drive 1 2 1 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 1 Top View--Right-Hand Drive 1 4 3 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 2 3 4 1 Top view--left-hand drive with clockwise shaft rotation. Top view--left-hand drive with anti-clockwise shaft rotation. Top view--right-hand drive with clockwise shaft rotation. Top view--right-hand drive with anti-clockwise shaft rotation. 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-19 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 5 standard 1 Speed Up to 800 cpm in 1:1 ratio Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter 1 1 1 1 1 1 Ratio 1:1 standard Shaft 0.31 in (7.9 mm) diameter stainless steel; 0.66 in (16.7 mm) right-hand drive, 0.63 in (15.9 mm) left-hand drive Drive Right- or left-hand spur gear drive Bearings Oil-less, maintenance free Figure size 1/4 in (6.4 mm) high, black-on-white background Finish Black frame and cover Reset Wing nut or non-reset Dimensions 1 Approximate Dimensions in Inches (mm) 1 D-7 Series 1.51 (38.5) 1 0.75 (19.0) 0.12 (3.2) 1 Dia. 0.31 (7.9) 1 1 1.17 (29.8) 0.50 (12.7) Dia. 0.120 (3.05) 4 Mtg. Holes 1.72 (43.6) 1 1 1.92 (48.8) 0.50 (12.7) 2.53 (64.3) 0.78 (19.8) 1.62 (41.3) 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-20 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 D-6 Series 1 Product Description 1 adapted as accessory equipment on machinery where right-angle drive is desired to permit full view reading of the counter. Model D-6 right-angle worm drive counters are ruggedly designed for high speeds on light-duty applications. Small "D" counters are easily 1 1 1 1 Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model D-6 Series Revolution Counters, consider: D-6 Series Revolution Counter 1 Shaft rotation direction 1 1 1 D-6 Series Revolution Counters No. of Figures Catalog Number Order Number Drive Rotation Reset Mounting 5 Front and rear Anti-clockwise 1 Wing nut Base 1 5-D-6-1-AC 31052401 6 Front and rear Anti-clockwise 1 Wing nut Base 6-D-6-1-AC 31052402 1 5 Front and rear Clockwise 2 Wing nut Base 5-D-6-1-CL 31052404 6 Front and rear Clockwise 2 Wing nut Base 6-D-6-1-CL 31052405 5 Front and rear Anti-clockwise 1 Wing nut Base 5-D-8-1-AC 3 40187401 2 Wing nut Base 5-D-8-1-CL 3 40187417 5 Front and rear Clockwise 6 Front and rear Clockwise 2 Wing nut Base 6-D-8-1-CL 3 40187418 5 Front and rear Clockwise 2 Wing nut Base 5-D-9-1-CL 4 40187404 5 Front and rear Anti-clockwise 1 Wing nut Base 5-D-9-1-AC 4 40187410 5 Front and rear Clockwise 2 Wing nut Base 5-D-90-1-CL 5 40187414 5 Front and rear Anti-clockwise 1 Wing nut Base 5-D-90-1-AC 5 40187408 1 1 1 1 1 1 Top View of Counter 1 1 1 1 2 1 Anti-Clockwise Shaft Rotation Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 1 1 2 3 4 5 Top view of counter--anti-clockwise shaft rotation. Top view of counter--clockwise shaft rotation. Special feature: Measuring wheels and brackets available for lineal measurement in feet. Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths. Special feature: Measuring wheels and brackets available for lineal measurement in yards. 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-21 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 5 or 6 1 Speed Up to 1500 cpm in 1:1 ratio Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter 1 Ratio 1:1 standard Shaft 0.31 in (7.9 mm) diameter stainless steel; 1.25 in (31.8 mm) length standard 1 Drive Worm drive 1 Bearings Oil-less, maintenance free Figure size 1/4 in (6.4 mm) high, black-on-white background Finish Black frame and cover Reset Wing nut 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) D-6 Series 1 1.16 (29.4) 1 1 1.23 (31.4) Reading Line 0.84 (21.4) A 1 Dia. 0.144 (3.66) 4 Mtg. Holes Dia. 0.31 (7.93) 1 0.12 (3.0) 0.34 (8.7) 2.0 (50.8) 1 1 2.81 (71.4) 0.50 (12.7) 1 1 1 0.66 (16.7) 3.19 (81.0) 0.75 (19.0) 1.62 (41.3) 2.00 (50.8) 3.62 (92.1) Note 1 A = 1.85 in (46.9 mm) for 6 figures and 1.53 in (38.9 mm) for 5 figures. 1 1 1 1 1 1 1 1 1 1 V13-T1-22 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 HDW Series 1 Product Description 1 eliminate slipping. They are particularly recommended for quick starting and stopping machines, such as coil winders and wire measuring or reeling equipment and on applications where continuous high speed measuring is required. Model HDW Series are high speed, end drive revolution counters that have the rugged features of all "H" counters, with the addition of double worm drive that produces speeds up to 2000 cpm. Lightweight precision molded wheels reduce centrifugal force and 1 1 1 1 1 Product Selection 1 When Ordering Specify To determine a model number from the Product Selection table for Model HDW Series Revolution Counters, consider: HDW Series Revolution Counter 1 Shaft drive Shaft rotation direction 1 1 HDW Series Revolution Counters No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 5 RH Clockwise 2 Wing nut Base 5-HDW-7-1-R-CL 31050400 5 RH Anti-clockwise 3 Wing nut Base 5-HDW-7-1-R-AC 31050401 5 LH Clockwise 4 Wing nut Base 5-HDW-7-1-L-CL 31050402 5 LH Anti-clockwise 5 Wing nut Base 5-HDW-7-1-L-AC 31050403 1 1 1 1 1 1 Top View--Right-Hand Drive 1 3 2 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Top View--Left-Hand Drive 1 1 5 4 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 2 3 4 5 1 Mounting plate is adjustable for base or back mounting. Top view--right-hand drive with clockwise shaft rotation. Top view--right-hand drive with anti-clockwise shaft rotation. Top view--left-hand drive with clockwise shaft rotation. Top view--left-hand drive with anti-clockwise shaft rotation. 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-23 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 5 1 Speed Up to 2000 cpm Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter 1 Ratio 1:1 only Shaft 0.31 in (7.9 mm) diameter stainless steel; standard length 2 in (50.8 mm) 1 Drive Right- or left-hand drive 1 Bearings Oil-less, maintenance free Figure size 11/16 in (17.5 mm) high, white-on-black background 1 Reset Wing nut or tumbler lock reset Finish Black frame and cover 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) HDW Series 0.75 (19.1) 1 2.75 (69.9) 0.98 (25.0) 0.96 (24.4) 2.00 (50.8) 1 2.76 (70.1) 1 1.80 (45.7) 1 4.51 (100.3) 4.94 (111.3) 1 1 1 Dia. 0.312 (7.9) Dia. 0.22 (5.59) 4 Mtg. Holes 0.90 (22.9) 0.34 (8.5) 1.12 (28.4) 2.25 (57.2) 1 1 1 1 1 1 1 1 1 1 1 V13-T1-24 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 T Series 1 Product Description 1 heavy machines, engines or motors. Variety of drive permits direct connection. Suitable for panel mounting. Model T Series worm drive revolution counters are sturdy, high speed instruments used on many 1 1 1 Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model T Series Revolution Counters, consider: T Series Revolution Counter 1 Shaft rotation direction 1 1 1 T Series Revolution Counters No. of Figures 5 Drive Rotation Top and bottom Anti-clockwise 2 Reset Mounting Catalog Number Order Number Wing nut Back 5-T-6-1-AC 40342401 1 1 1 1 1 Top View of Counter 1 1 1 2 1 Clockwise Shaft Rotation 1 Anti-Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 2 3 4 5 1 Top view of counter--clockwise shaft rotation. Top view of counter--anti-clockwise shaft rotation. Special feature: Measuring wheels and brackets available for lineal measurement in feet. Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths. Special feature: Measuring wheels and brackets available for lineal measurement in yards. 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-25 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 5 standard 1 Speed 1500 cpm in 1:1 ratio Rotation direction Clockwise or anti-clockwise determined top looking down 1 Ratio 1:1 standard Shaft 0.31 in (7.9 mm) diameter stainless steel; standard extends 2 in (50.8 mm) top and bottom 1 Drive Hobbed steel and bronze worm gearing; subtracts when reversed 1 Bearings Oil-less, maintenance free Figure size 11/32 in (8.7 mm) high, black-on-white background Reset Left-hand wing nut standard Finish Black frame and face plate 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) T Series 1 1.38 (35.1) 1 1 1 0.75 (19.1) 0.24 (6.2) 2.97 (75.4) 0.62 (15.9) 0.47 (11.9) 2.38 (60.5) 1 1 1 1.36 (34.5) 4.50 (114.2) 1 5.00 (127.0) 1.87 (47.6) 1.41 (35.7) 2.19 (55.6) 0.25 (6.4) 1/4-20 UNC-2B 4 Mtg. Holes 1 1 1 1 1 1 1 1 1 1 1 V13-T1-26 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers H Series 1 Product Description Model H Series are heavyduty, end drive revolution counters designed for industrial use; suitable for 1 speeds up to 800 cpm. They are available with either rightor left-hand drive, and with wing nut reset. 1 1 Product Selection When Ordering Specify To determine a model number from the Product Selection table for Model H Series Revolution Counters, consider: H Series Revolution Counter 1 Drive shaft location Shaft rotation direction 1 1 1 H Series Revolution Counters No. of Figures Drive Rotation Reset Mounting 1 Ratio Catalog Number Order Number 5 LH Clockwise 2 Wing nut Base 1.1 5-H-7-1-L-CL 00509400 5 LH Anti-clockwise 3 Wing nut Base 1.1 5-H-7-1-L-AC 00510400 5 RH Clockwise 4 Wing nut Base 1.1 5-H-7-1-R-CL 00513400 5 5 RH Anti-clockwise Wing nut Base 1.1 5-H-7-1-R-AC 00514400 5 LH Clockwise 6 Wing nut Base 3.2 5-H-8-1-L-CL 7 00601400 5 LH Anti-clockwise 8 Wing nut Base 3.2 5-H-8-1-L-AC 7 00602400 5 RH Clockwise 6 Wing nut Base 3.2 5-H-8-1-R-CL 7 00605400 5 RH Anti-clockwise 8 Wing nut Base 3.2 5-H-8-1-R-AC 7 00606400 5 LH Clockwise 6 Wing nut Base 1.2 5-H-9-1-L-CL 9 00619400 5 LH Anti-clockwise 8 Wing nut Base 1.2 5-H-9-1-L-AC 9 00620400 9 00617400 6 5 RH Clockwise Wing nut Base 1.2 5-H-9-1-R-CL 5 RH Anti-clockwise 8 Wing nut Base 1.2 5-H-9-1-R-AC 9 00618400 5 LH Clockwise 6 Wing nut Base 1.2 5-H-9-0-1-L-CL j 00611400 5 RH Clockwise 6 Wing nut Base 1.2 5-H-9-0-1-R-CL j 00609400 5 RH Anti-clockwise 8 Wing nut Base 1.2 5-H-9-0-1-R-AC j 00610400 For 5-H-8 and 5-H-9 Series Counters, drive shaft extends from both sides of the counter. Specifying RH or LH drive will determine the location of the reset (i.e. LH drive will have reset on the right-hand side of the counter, and RH drive will have reset on left-hand side of the counter). Top View--LH Drive Top View--RH Drive 2 Clockwise Shaft Rotation 4 Clockwise Shaft Rotation Top View--RH and LH Drive 1 1 1 1 1 1 1 1 1 1 1 1 6 1 Clockwise Shaft Rotation 1 3 Anti-Clockwise Shaft Rotation 5 Anti-Clockwise Shaft Rotation 8 Anti-Clockwise Shaft Rotation 1 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 Mounting plate is adjustable for base or back mounting. 2 Top view--left-hand drive with clockwise shaft rotation. 3 Top view--left-hand drive with anti-clockwise shaft rotation. 4 Top view--right-hand drive with clockwise shaft rotation. 5 Top view--left-hand drive with anti-clockwise shaft rotation. 6 Top view--right-hand and left hand drive with clockwise shaft rotation. 7 Special feature: Measuring wheels and brackets available for lineal measurement in feet. 8 Top view--right-hand and left hand drive with anti-clockwise shaft rotation. 9 Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths. j Special feature: Measuring wheels and brackets available for lineal measurement in yards. 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-27 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 5 1 Speed Up to 800 cpm Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter 1 Shaft 0.31 in (7.9 mm) diameter stainless steel; standard length 2 in (50.8 mm) Drive Right- or left-hand drive 1 Bearings Oil-less, maintenance free 1 Figure size 11/32 in (8.7 mm) high, white-on-black background Reset Wing nut Finish Black frame and cover Mounting bracket available Order number 01465400 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) H Series 1 2.75 (69.9) 1 0.98 (25.0) 2.00 (50.8) 1 2.76 (70.1) 1 0.91 (23.0) 1.80 (45.7) 1 1 3.95 (100.4) 4.38 (111.3) 1 Dia. 0.312 (7.92) Dia. 0.220 4 Mtg. Holes 0.34 (8.5) 1.12 (28.4) 2.25 (57.2) 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-28 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Contents Electromechanical Totalizers Description Mechanical Totalizers Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical Totalizers Micro Display Counter . . . . . . . . . . . . . . . . . . . SE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RMF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . ME Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . Page 1 V13-T1-5 V13-T1-14 1 V13-T1-30 V13-T1-32 V13-T1-34 V13-T1-36 V13-T1-38 V13-T1-41 1 1 1 1 1 1 1 1 1 Electromechanical Totalizers Product Overview Features Eaton's electromechanical counters provide accurate counting from a variety of electrical signals and a display that is always readable, even when power is not present. Available with reset and without Always readable display Variety of mounting options 1 Standards and Certifications UL certifications on some products (see individual product pages for details) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-29 1.1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Micro Display Counter Product Description Features Eaton's micro display counter is perfect for 12 Vdc applications where small size is important. 1 1 1 1 Standards and Certifications Seven-digit micro adding counter High shock resistance Low power consumption; suitable for battery consumption Small dimensions Large optical figures Different viewing possibilities Flush mount with integrated spring clip Protection IP65 Stores value also at power failure Long service life Product Selection Micro Display Counter 1 Micro Display Counter Description Catalog Number Micro display counter 7-Y-3013PM-401 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification 1 Electrical connections Built-in counter, flying leads, AWG 22, approx. 5.9 in (150 mm) Power consumption At 68F (20C) and nominal voltage 1 1 At 25 lmp/s: approx. 250 mW Rated voltage 12 Vdc 10% Counting frequency 25 lmp/s Pulse duration Min. 20 ms 1 Pulse interval Min. 20 ms 1 Cycle duration factor 100% Number of digits 7 1 Counting system Adding Figure size 0.05 x 0.16 in (1.2 x 4 mm) high optical 1 Color of figures White-on-black 1 Reset No reset Ambient temperature 14 to 140F (-10 to 60C) 1 Mounting position Any Operating Life >50 x 106 pulses 1 Protection IP65 (only front side) Housing Clear plastic Weight 0.53-0.71 oz (15-18g) 1 1 1 1 1 1 1 V13-T1-30 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com cRU(R)us certified CE marked Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Dimensions Approximate Dimensions in Inches (mm) 1 Micro Display Counter 1 1 0.08 (2) 0.04 (1.1) 0.51 x 1.18 (13 x 29.9) 1.26 (32) 1 Rmax 0.02 (0.5) 1 0.59 (15) 0.12 (3) Max. 0.59 (15) 1.18 (30 +0.3) +0.01 1 0.51 +0.02 (13 +0.5) 1 1.29 (32.7) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-31 1.1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers SE Series Product Description Features Compact electromechanical counters. 1 1 1 1 Standards and Certifications Low-cost electromechanical counter Multiple voltage ranges for almost any application Compact with various mounting options Wire leads for electrical connections Product Selection SE Series Counter-- Electromechanical SE Series Electromechanical Counters Description Catalog Number Order Number 1 Six-Digit Electric Counter 1 Bottom mount sub-miniature 12 Vdc 6-Y-41610-401-SE 41610401 Bottom mount sub-miniature 24 Vdc 6-Y-41610-402-SE 41610402 1 Bottom mount sub-miniature 120 Vac 6-Y-41610-406-SE 41610406 Bottom mount sub-miniature 240 Vac 6-Y-41610-407-SE 41610407 1 Base mount sub-miniature 12 Vdc 6-Y-41611-401-SE 41611401 Base mount sub-miniature 24 Vdc 6-Y-41611-402-SE 41611402 1 1 1 1 Base mount sub-miniature 120 Vac 6-Y-41611-406-SE 41611406 Base mount sub-miniature 240 Vac 6-Y-41611-407-SE 41611407 Panel mount sub-miniature 12 Vdc 6-Y-41613-401-SE 41613401 Panel mount sub-miniature 24 Vdc 6-Y-41613-402-SE 41613402 Panel mount sub-miniature 120 Vac 6-Y-41613-406-SE 41613406 Panel mount sub-miniature 240 Vac 6-Y-41613-407-SE 41613407 41622401 Special base mount sub-miniature 12 Vdc 6-Y-41622-401-SE 1 Special base mount sub-miniature 24 Vdc 6-Y-41622-402-SE; 41622402 1 Special base mount sub-miniature 120 Vac 6-Y-41622-406-SE 41622406 Special top mount sub-miniature 12 Vdc 6-Y-41623-401-SE 41623401 1 Special top mount sub-miniature 24 Vdc 6-Y-41623-402-SE 41623402 Special top mount sub-miniature 120 Vac 6-Y-41623-406-SE 41623406 1 1 1 Special top mount sub-miniature 240 Vac 6-Y-41623-407-SE 41623407 Snap-in mount sub-miniature 12 Vdc 6-Y-42613-401-SE 42613401 Snap-in mount sub-miniature 24 Vdc 6-Y-42613-402-SE 42613402 Snap-in mount sub-miniature 120 Vac 6-Y-42613-406-SE 42613406 Snap-in mount sub-miniature 240 Vac 6-Y-42613-407-SE 42613407 1 1 1 1 1 1 1 1 1 V13-T1-32 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL recognized 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 6 Count speed 600 cpm 1 1 Figure size 5/32 in (4.0 mm) Reset None Mounting Base, bottom, top, panel or snap-in Finish Black, self-extinguishing plastic Power requirements DC: 1.5W, AC: 5.0V 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 SE Series Bottom Mount Base Mount 1.01 (25.7) 1.00 (25.4) 1.31 (33.2) 1.00 (25.4) 10 (254) 0.63 (15.9) 0.69 (17.4) 1.88 (47.6) 2.19 (55.5) 2.16 (54.9) 10 (254) 1.50 (38.1) 0.14 (3.6) Dia. 1.75 2.34 (44.5) (59.5) 1.97 (50) 1.13 (28.6) 10 (254) 2.16 (54.9) 0.88 (22.2) 1.0 (25.4) 2.16 (54.9) Special Top Mount 1 1 1 1 Snap Mount 1 1.06 (26.9) 1.44 (36.5) 2.16 (54.9) 1 1 2.16 (54.9) 10 (254) 1 1 1.00 (25.4) 1.31 (33.2) 10 (254) 1.80 (45.7) Panel Cutout 1.43 x 1.13 (36.3 x 28.6) 0.19 (4.7) (2) #4-40 Mounting Holes 1.52 Mounting Holes (38.7) for #6 FHMS 1.31 (33.2) (4) 0.13 (3.2) Dia. Mounting Holes 10 (254) 1 Panel Mount (2) #4-40 Mounting Holes 2.16 (54.9) (2) #4-40 UNC 28 Special Base Mount Top Mount 10 (254) 1 1.81 (46.0) 1 2.16 (54.9) 1 1 Panel Cutout 1.70 x 1.33 (43.2 x 33.8) 1 0.19 (4.7) 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-33 1.1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers MF Series Product Description Model MF Series are shaded pole electric counters with straight AC operation and feature a non-rectified, shaded pole coil designed to withstand transient, high voltage spikes. This feature, combined with a simplified, hinged escapement drive, also eliminates the possibility of miscounts and greatly adds to the life of the counter. Tallies at speeds up to 750 cpm. Product Selection MF Series Electric Counter 1 1 1 MF Series Electric Counters No. of Figures Voltage Reset Mounting Catalog Number Order Number 7 120 Vac Knob Base 7-Y-1-MF-120A 1 32650400 6 120 Vac Knob Base 6-Y-1-MF-120A 1 32651400 7 120 Vac Knob Panel 7-Y-1-MF-PM-120A 1 1 32652400 7 120 Vac Non-reset Panel 7-Y-13-MF-PM-120A 1 6 120 Vac Knob Panel 6-Y-1-MF-PM-120A 1 32653400 6 120 Vac Non-reset Panel 6-Y-13-MF-PM-120A 1 32653405 1 6 120 Vac Keylock reset Panel 6-Y-12-MF-PM-120A 1 32654400 6 24 Vac Keylock reset Panel 6-Y-12-MF-PM-24A 32654403 7 120 Vac Keylock reset Panel 7-Y-12-MF-PM-120A 1 32655400 6 120 Vac Non-reset Base 6-Y-13-MF-120A 1 32658400 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Figures 6 or 7 1 Speed Up to 750 cpm 1 Figure size 3/16 in (4.8 mm) high, white-on-black background Reset Knob, key or non-reset 1 Mounting Base or panel mount Finish Black frame and side covers 1 Electrical connections Two-wire leads, 9 in (229 mm) long, AWG 22 (0.34 mm2), stripped 0.38 in (9.5 mm) Power requirements 12 watts Coils Various AC voltages and frequencies can be supplied on special order. Count coils are designed for continuous duty at rated voltage. 1 1 1 32652402 Specification Note 1 UL Recognized. 1 1 1 1 1 1 V13-T1-34 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1.1 Counters, Panel Meters, Tachometers and Timers Totalizers Dimensions Approximate Dimensions in Inches (mm) 1 MF Series 1 Panel Mounted 4.37 (111.1) 4.00 (101.6) A B 0.19 (4.8) 5.50 (139.7) 5.12 (130.2) C D 0.19 (4.8) 0.30 (7.5) 0.16 (4.0) 1.62 1.25 (41.3) (31.8) Dia. 0.15 (3.81) 4 Mtg. Holes 2.56 (65.0) 1 Panel Mounted with Tumbler Lock 1 0.12 0.19 (3.0) (4.8) 1 1 1.75 2.12 (44.5) (54.0) 1 0.97 (24.6) #6-32 Top Mount Models Only 4 Mtg. Holes Dia. 0.15 (3.81) 4 Mtg. Holes 2.56 (65.0) 2.09 (53.1) 1 1.25 (31.8) 0.09 (2.4) Panel Panel 1 0.06 (1.6) 1 1 3.68 (93.5) 0.62 (15.7) 0.56 (14.2) 0.25 (6.3) 2.56 (65.0) 1 4.62 x 1.44 (117.3 x 36.5) Panel Opening 3.68 (93.5) 1 3.51 x 1.44 (89.3 x 36.5) Panel Opening 1 Base Mounted 1 3.31 (84.1) 0.28 (7.1) E F 1 0.87 1.37 (22.2) (34.9) 1 Dia. 0.14 (3.6) 4 Mtg. Holes 1 1 0.41 (10.3) 3.16 (80.2) 2.56 (65.0) 1 1 0.25 2.09 (6.3) (53.1) 1 0.62 (15.7) 0.56 (14.2) 2.56 (65.0) 3.68 (93.5) 1 1 Model A B C D E F Six figures 1.73 (44.0) 1.58 (40.0) 1.73 (43.9) 2.80 (71.1) 1.73 (44.0) 1.12 (28.6) Seven figures 2.02 (51.4) 1.29 (32.7) 2.03 (51.6) 2.50 (63.5) 2.02 (51.4) 0.84 (21.2) 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-35 1.1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers RMF Series Product Description 1 Model RMF Series of electric counters are designed to give accurate counts through a wide range of speeds up to 1000 cpm. It features a strong, silent, fast operating DC electromagnetic drive with a compact, dependable 1 Product Selection 1 1 1 1 1 1 built-in higher capacity rectifier for AC operation. The counter has a minimum of moving parts that never need lubrication under normal operating conditions. Compact and rigid, it When Ordering Specify To determine a model number from the Product Selection table for Model RMF Series Electronic Counters, consider: RMF Series Counter-- Electromechanical continues to operate dependably even when subject to severe shock and vibrations. Entirely enclosed to prevent damage from moisture and dust. Available in 6 or 7 figures. Number of figures Voltage Type of reset Type of mounting RMF Series Electromechanical Counters No. of Figures Voltage Reset Mounting Catalog Number Order Number 1 6 24 Vdc Knob Panel 6-Y-1-RMF-PM-24D 31013400 7 24 Vdc Knob Panel 7-Y-1-RMF-PM-24D 31019400 1 7 115 Vac Knob Base 7-Y-1-RMF-115A 1 31025400 7 115 Vac Non-reset Base 7-Y-13-RMF-115A 1 31026400 1 7 115 Vac Knob Panel 7-Y-1-RMF-PM-115A 1 31026401 1 7 115 Vac Non-reset Panel 7-Y-13-RMF-PM-115A 1 31026402 6 115 Vac Non-reset Base 6-Y-13-RMF-115A 1 31039400 1 6 230 Vac Knob Panel 6-Y-1-RMF-PM-230A 31066413 6 115 Vac Knob Panel 6-Y-1-RMF-PM-115A 1 31066416 1 6 115 Vac Keylock reset Panel 6-Y-12-RMF-PM-115A 1 31083403 6 230 Vac Keylock reset Panel 6-Y-12-RMF-PM-230A 31083405 1 7 115 Vac Keylock reset Panel 7-Y-12-RMF-PM-115A 1 31083409 1 6 24 Vac Keylock reset Panel 6-Y-12-RMF-PM-24A 31083411 6 24 Vdc Keylock reset Panel 6-Y-12-RMF-PM-24D 31083415 7 24 Vdc Keylock reset Panel 7-Y-12-RMF-PM-24D 31083421 7 230 Vac Keylock reset Panel 7-Y-12-RMF-PM-230A 31083427 6 24 Vac Knob Base 6-Y-1-RMF-24A 31155400 1 1 1 6 240 Vac Knob Base 6-Y-1-RMF-240A 31155401 1 6 115 Vac Knob Base 6-Y-1-RMF-115A 1 31155402 115 Vac Non-reset Panel 6-Y-13-RMF-PM-115A 1 31155405 1 6 7 24 Vdc Non-reset Panel 7-Y-13-RMF-PM-24D 33183400 Note 1 UL recognized. 1 1 1 1 1 1 1 V13-T1-36 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 6 or 7 Speed Up to 1000 cpm Figure size 3/16 in (4.8 mm) high, white-on-black background Reset Knob, key or non-reset Mounting Base or panel mount Finish Black frame and side covers Electrical connections Two-wire leads, 9 in (229 mm) long, AWG 22 (0.34 mm2), stripped 0.38 in (9.5 mm) Power requirements 7 watts Coils Various voltages and frequencies can be supplied on special order. Count coils are designed for continuous duty at rated voltage 1 1 1 1 1 1 1 Dimensions 1 Refer to table and illustrations on Page V13-T1-35 for information. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-37 1.1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers ME Series Product Description Small in size and price, but large in design versatility and model variety is the ME Series of miniature electric counters. Models in most popular AC or DC voltages operate on as little as 3 watts, with the non-reset 1 Standards and Certifications models measuring only 1 x 1.593 x 2.187 in (25.4 x 40.5 x 55.5 mm) and weighing just three ounces (85 grams). Available in 4, 6 or 7 figures, the counters feature stainless steel self-lubricating shafts, nylatron pinions and a synchronous electromagnetic drive to assure accurate, reliable, long life operation. Designed for mounting flexibility and aesthetic attractiveness, the miniature electric counters are available with three types of mounting and a glare retarding finish Delrin, with crisp easy-to-read numerals set close to a tamper-proof sealed figure window. Bottom Mount Wire Leads Base Mount Wire Leads 1 1 1 1 1 When Ordering Specify When ordering ME Series Miniature Electric Counters, specify catalog numbers according to the features selected. 1 1 UL recognized Product Selection 1 1 ME Series Miniature Electric Counter ME Series Miniature Electric Counters No. of Figures Voltage Reset Mounting Catalog Number Order Number 1 4 12 Vdc Pushbutton Bottom 4-Y-41312-401-MEQ 41312401 1 4 24 Vdc Pushbutton Bottom 4-Y-41312-402-MEQ 41312402 4 120 Vac Pushbutton Bottom 4-Y-41312-406-MEQ 41312406 1 4 24 Vdc Pushbutton Base 4-Y-41313-402-MEQ 41313402 4 120 Vac Pushbutton Base 4-Y-41313-406-MEQ 41313406 1 4 240 Vac Pushbutton Base 4-Y-41313-407-MEQ 41313407 1 4 12 Vdc Pushbutton Panel 4-Y-41314-401-MEQ 41314401 4 24 Vdc Pushbutton Panel 4-Y-41314-402-MEQ 41314402 4 120 Vac Pushbutton Panel 4-Y-41314-406-MEQ 41314406 4 240 Vac Pushbutton Panel 4-Y-41314-407-MEQ 41314407 1 1 1 1 1 1 1 1 1 1 V13-T1-38 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Panel Mount Wire Leads Counters, Panel Meters, Tachometers and Timers Totalizers ME Series Miniature Electric Counter 1.1 ME Series Miniature Electric Counters, continued No. of Figures Voltage Reset Mounting Catalog Number Order Number 6 24 Vdc Non-reset Bottom 6-Y-41119-402-ME 41119402 6 120 Vac Non-reset Bottom 6-Y-41119-406-ME 41119406 6 12 Vdc Non-reset Base 6-Y-41345-401-ME 41345401 6 24 Vdc Non-reset Base 6-Y-41345-402-ME 41345402 6 120 Vac Non-reset Base 6-Y-41345-406-ME 41345406 6 240 Vac Non-reset Base 6-Y-41345-407-ME 41345407 6 12 Vdc Non-reset Panel 6-Y-41346-401-ME 41346401 6 24 Vdc Non-reset Panel 6-Y-41346-402-ME 41346402 6 120 Vac Non-reset Panel 6-Y-41346-406-ME 41346406 6 240 Vac Non-reset Panel 6-Y-41346-407-ME 41346407 7 12 Vdc Non-reset Bottom 7-Y-41238-401-ME 41238401 7 24 Vdc Non-reset Bottom 7-Y-41238-402-ME 41238402 7 120 Vac Non-reset Bottom 7-Y-41238-406-ME 41238406 7 12 Vdc Non-reset Base 7-Y-41337-401-ME 41337401 7 24 Vdc Non-reset Base 7-Y-41337-402-ME 41337402 7 120 Vac Non-reset Base 7-Y-41337-406-ME 41337406 7 12 Vdc Non-reset Panel 7-Y-41349-401-ME 41349401 7 24 Vdc Non-reset Panel 7-Y-41349-402-ME 41349402 7 120 Vac Non-reset Panel 7-Y-41349-406-ME 41349406 7 240 Vac Non-reset Panel 7-Y-41349-407-ME 41349407 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 4, 6 and 7 Speed Up to 1000 cpm Figure size 3/16 in (4.8 mm) high Reset Pushbutton and non-reset Reset force Pushbutton models only, 20 oz. (568 grams) maximum Mounting Base, bottom, panel Finish Black self-extinguishing plastic Electrical connections Wire leads, 10 in (254 mm) long, AWG 20, stripped 3/8 in (9.5 mm), and pin terminals Power requirements 3W Coils Count coils are designed for continuous duty at rated voltage 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-39 1.1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Dimensions Approximate Dimensions in Inches (mm) 1 ME Series Counters 1 Panel Mounted Bottom Mounted Base Mounted Bottom Mounted 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Recommended Panel Mount Cut-Outs ME Series Counters 4 Figure Pushbutton Reset Counters 6 and 7 Figure Non-Reset Counters 4 Figure Counters 6 and 7 Figure Counters Dimension Dimension Inches (mm) Pushbutton Reset Non-Reset 1.72 x 1.11 (43.7 x 28.2) 1.72 x 1.11 (43.7 x 28.2) Inches (mm) A 1.00 (25.4) A 1.00 (25.4) 1 B 1.60 (40.6) B 1.60 (40.6) C 2.64 (67.1) C 2.38 (60.5) 1 D 2.19 (55.6) D 2.19 (55.6) 1 E 1.80 (45.7) E 1.80 (45.7) F 1.80 (45.7) F 1.80 (45.7) 1 G 1.40 (35.6) G 1.40 (35.6) H 0.69 (17.5) H 0.69 (17.5) 1 J 1.88 (47.8) J 1.88 (47.8) K 0.50 (12.7) K 0.50 (12.7) 1 1 1 1 1 L 0.49 (12.4) L 0.49 (12.4) M 0.94 (23.9) M 0.94 (23.9) N 2.45 (62.2) N 2.19 (55.6) P 2.45 (62.2) P 2.19 (55.6) Q 0.45 (11.4) Q 0.45 (11.4) R 0.63 (16.0) R 0.63 (16.0) S 0.19 (4.8) S 0.19 (4.8) T 0.68 (17.3) T 0.88 (22.4) V13-T1-40 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Contents Electronic Totalizers Description Mechanical Totalizers Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical Totalizers . . . . . . . . . . . . . . . . . Electronic Totalizers 1/32 DIN LCD Totalizers . . . . . . . . . . . . . . . . . . 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter . . . . . . . . . . . . . . . Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . . 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter . . . . . . . . . . . . . . . Page V13-T1-5 V13-T1-14 V13-T1-29 1 1 1 1 V13-T1-42 1 V13-T1-44 V13-T1-46 1 V13-T1-49 1 1 1 1 1 Electronic Totalizers Product Overview Features Eaton's electric totalizers provide a flexible and accurate method of displaying count and measurement data in an easily readable format. LED and LCD readouts Variety of sizes and packages Programmable inputs and displays available 1 Standards and Certifications Most products are UL certified (see individual product pages for details) CE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-41 1.1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers 1/32 DIN LCD Totalizers Product Description Features Compact battery powered totalizers where AC power is unavailable. 1 1 1 1 Standards and Certifications Low price and high efficiency Large eight-digit LCD display, height of the figures 0.31 in (8 mm) Various counting modes like up/down differential available High voltage input for 10-260 Vac/Vdc voltage pulses IP65 Screw terminals, RM 5 mm Lifetime of the battery approximately eight years Locking of the reset key Operating temperature 14 to 140F (-10 to 60C) All version of positive or negative counting edge Filter function for bouncefree counting with mechanical contacts 1 1 Product Selection 1 E5-024-C04_ 1/32 DIN LCD Totalizers Description 1 Catalog Number Eight-Digit LCD Totalizer, Battery Power 1 4-30 Vdc powered, NPN/PNP 0.94 x 1.89 in (24 x 48 mm) E5-024-C0400 1 10-120V input AC/DC powered, NPN only 0.94 x 1.89 in (24 x 48 mm) E5-024-C0408 Count up/down 4-30 Vdc powered, NPN only, 0.94 x 1.89 in (24 x 48 mm) E5-024-C0410 1 1 1 1 Technical Data and Specifications 1/32 DIN LCD Totalizers Description Specification Power supply Non-replaceable lithium battery (lifetime approximately eight years at 68F (20C) 1 Display LCD, eight-digits Figure size 0.31 in (8 mm) high 1 Mode Adding or subtracting (selectable), counting direction, differential counting or phase discriminator single or dual evaluation (selectable) 1 Display range -9999999 to 99999999, with overflow display Reset Manual and electrical 1 Interference emissions EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions) 1 Housing Dark gray RAL 7021 Operating temperature 14 to 131F (-10 to 55C) 1 Ambient temperature 14 to 140F (-10 to 60C) Storage temperature -4 to 158F (-20 to 70C) 1 Protection IP65 (from front) Weight Approx. 1.76 oz (50g) 1 1 1 1 1 1 V13-T1-42 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL recognized CE marked Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 1/32 DIN LCD Totalizers, continued Description 1 Specification 1 Counting inputs: Counting input of the DC version Max. 30 Vdc 1 Slow counting input Max. 30 Hz (NPN) Fast counting input Max. 12 kHz (PNP) Switching level NPN: Low 0-0.7V, High 3-30 Vdc 1 PNP: Low 0-0.7V, High 3-30 Vdc Counting Input of the high voltage versions 1 10-260 Vac/Vdc Counting input 1 Optocoupler input, max. 30 Hz Min. pulse time 16 ms Switching level Low: 0-2 Vac/Vdc 1 High: 10-260 Vac/Vdc Counting direction switching (only DC versions) 1 Contact input, open collector NPN (switching at 0 Vdc) Switching level, NPN--Low, 0-0.7V, High 3-5 Vdc 1 Minimum pulse time DC: 50 ms; high voltage: 16 ms Contact input NPN Low: 0-0.7V 1 Reset input (only DC and high voltage)-- 1 High: 3-30 Vdc High voltage input 10-260 Vac/Vdc Electrical reset key locking (for DC and AC) 1 Contact input, open collector NPN (switching at 0V) Switching level, NPN--Low, 0-0.7V, High 3-5 Vdc 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 1/32 DIN LCD Totalizers 1 MAX. 1.89 (19.3) 1 1.89 (48) 1 0.87 x 1.77 (22 x 45) 0.94 (24) 1 0.11 (2.8) 1.88 (47.7) 1 0.12 (3) 1 1.77 + 0.024 (45 + 0.6) 1 1.77 (22.2 +0.3) 1 + 0.012 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-43 1.1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter Product Description Features Compact LED display for a variety of input signals. 1 Display counter adding and subtracting Position display Frequency counter/ ratemeter Standards and Certifications Timer Display range: -199.999 to 999.999 with zero blanking Screw terminal Locking SET-key 1 1 Product Selection 1 E5-024-C04_ 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter Description Catalog Number 1 LED Single channel totalizer, 10-30 Vdc power 0.94 x 1.89 in (24 x 48 mm) E5-024-E0402 1 LED multifunction totalizer/timer/ratemeter 10-30 Vdc power 0.94 x 1.89 in (24 x 48 mm) E5-424-E0402 1 LED double-function totalizer/timer/ratemeter 10-30 Vdc power 0.94 x 1.89 in (24 x 48 mm) E5-524-E0402 1 LED totalizer with quadrature, 10-30 Vdc power 0.94 x 1.89 in (24 x 48 mm) E5-024-E0432 1 1 1 1 Technical Data and Specifications General Specifications Description Specification Supply voltage 10-30 Vdc with reverse polarity protection 1 Current consumption Max. 55 mA Display Six-digit red, seven-segment LED display 1 Figure size 0.31 in (8 mm) high Data backup EEPROM 1 Housing Dimension 3.78 x 1.89 in (48 x 24 mm) according to DIN 43 700; RAL 7021 gray 1 Polarity of inputs Programmable, NPN or PNP Input resistance Approx. 10k ohms 1 Counting frequency 60 kHz, can be damped to 30 Hz, position display max. 25 kHz Resolution Timer 0.001 sec. 1 Reset time 5 ms 1 1 1 Level of inputs High 0.6 x UB-30 Vdc Low 0-0.2 x UB (Vdc) Error Tachometer <0.1% Timer <50 ppm 1 Ambient temperature 4 to 131F (-20 to 55C) Storage temperature -13 to 167F (-25 to 75C) 1 EMC According to EC EMC directive 89/36/EWG 1 Immunity to interference EN 61 000-6-4/ EN 55011 Class B Emitted interference EN 61 000-6-2 Protection IP65 (from front) Weight Approx. 5.29 oz (150g) 1 1 1 V13-T1-44 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL recognized CE marked Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Dimensions Approximate Dimensions in Inches (mm) 1 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter 1 0.87 x 1.77 (22.0 x 45.0) 1.89 (48.0) Max. 0.76 (19.3) 1 Connections: 1 0.94 (24.0) 1 Panel Cut-Out: 0.87 + 0.01 x 1.77 + 0.02 (22.2 + 0.3 x 45 + 0.6) 1 0.16 (4.0) 1 0.26 (6.5) 2.32 (59.0) 1 1.10 (28.0) 1 1.97 (50 + 0.6) 2.09 (53.0) + 0.02 1 0.98 x 1.97 (25 x 50) 0.98 + 0.02 (25 + 0.5) 0.04 (1.0) 1 1 Panel Cut-Out 1 0.16 (4.0) 1.57 (40) 1.26 (32) 1 1.97 + 0.02 (50 + 0.6) 2.20 (56.0) 0.98 x 1.97 (25 x 50) 0.04 (1.0) 1 1.26 + 0.004 (32 + 0.1) 0.98 + 0.02 (25 + 0.5) 0.16 (4.0) 1 1 1 M3 Panel Cut-Out 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-45 1.1 1 1 1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Courier Series Product Description Features Eaton's Courier Series is a high quality totalizer powered by a replaceable lithium battery. Eight-digit totalizer 1/Tau ratemeter Scaling capabilities Remote reset terminal Standards and Certifications 0.43 in (10.9 mm) display Front panel reset NEMA 4X Product Selection When Ordering Specify When ordering Courier Series Electronic Totalizers and Ratemeters, specify order numbers according to the features selected. Courier Series Courier Series, Eight-Digit LCD Description Catalog Number 1 Totalizer, battery 53300400 1 Add/subtract (10k Hz, PNP input) totalizer, battery 53300401 Add/subtract (20 Hz, NPN/contact input) totalizer, battery 53300402 1 Quadrature (10k Hz, PNP input) totalizer, battery 53300403 Totalizer/ratemeter, battery 53300405 1 Totalizer/ratemeter at 100 Hz, battery 53300465 53300800 1 RMF panel mount totalizer, key reset, 60-160 Vac/Vdc count input RMF panel mount totalizer, dry contact input 53300850 1 RMF panel mount totalizer, 60-160 Vac/Vdc count input 53300851 Totalizer--extended temperature range, battery 53301400 1 Totalizer--1/Tau ratemeter--extended temperature range 53301404 Totalizer/ratemeter--extended temperature range, battery 53301405 1 Totalizer/ratemeter, mag pickup, battery 53301475 1 Backlight totalizer, battery 53302400 Backlight add/subtract (10k Hz, PNP input) totalizer, battery 53302401 1 Backlight add/subtract (20 Hz, NPN/contact input) totalizer, battery 53302402 Backlight quadrature (10k Hz, PNP input) totalizer, battery 53302403 1 Backlight totalizer/ratemeter, battery 53302405 1 1 1 1 1 1 1 1 1 V13-T1-46 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com CE marked Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 Technical Data and Specifications 1 General Specifications Specification 1 Internal battery 3V, lithium 1 Life expectancy 5 years + Replacement part 36367-202 1 10-30 Vdc at 30 mA max. 1 1 Description Power Backlight Backlight Reverse polarity protected 1 Operating temperature -4 to 158F (-20 to 70C) Storage temperature -4 to 158F (-20 to 70C) 1 Operating humidity 60% non-condensing Weight 2.2 oz (62g) net Physical 1 1 Figure size 0.43 in (10.9 mm) high Front panel rating NEMA 4X when mounted with gasket provided Case material Cycolac X-17 1 Type UP counting Digits Eight 1 Totalizer 1 Count Accuracy Operated within specifications 100% 1 DC Common (Terminal 1) Count Inputs Input B (terminal 2) low speed input designed for contact closures to DC common Speed 1 0 to 20 Hz 1 Min. low time 10 ms Min. high time 40 ms Input impedance 101k ohms Voltage thresholds Low 1 0-0.4 Vdc 1 High 2.0-28 Vdc Max. high 28 Vdc 1 Input A (terminal 3) high speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed 0 to 10 kHz 1 1 Min. low time 2 80 ms Min. high time 2 20 ms Input impedance 2k ohms above 5 Vdc 1 Voltage thresholds Low 0-1.2 Vdc 1 High 2.0-28 Vdc Max. high 28 Vdc 1 Reset Input 1 Reset input (terminal 4) designed for contact closures to DC common Min. low 3 0.25 to 1 sec. (reset is maintained) 1 Voltage thresholds Low 0-0.4 Vdc 1 High 2.0-28 Vdc 1 Front Panel Reset Enable Front panel reset enable (terminal 5) Operation 1 Level sensitive (maintained) Notes 1 Derate operating temperature 1C/volt above 17 Vdc. 2 The times are with a 0-5.0V swing. 3 The required pulse width varies with count speed, scale factor and number of digits displayed. Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 1 V13-T1-47 1.1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Dimensions Approximate Dimensions in Inches (mm) Courier Series 1 1.25 (31.8) 1 1 1 1 2.95 (74.9) 1 2.67 (67.8) 1 1 1.57 (39.9) T/R Recommended Panel Cutout 1.30 (33.0) RST 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-48 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Totalizers 1.1 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter Product Description Features LED display for a variety of input signals. Standards and Certifications Display counter adding and subtracting Position display Frequency counter/ ratemeter Timer, res. up to 0.001 second Programmable mode Display range: -199.999 to 999.999 with zero blanking Connection with screw terminal Locking SET-key for reset UL recognized CE marked 1 1 1 1 1 1 Product Selection E5-496-E040_ 1 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter Description 1 Catalog Number 1 LED Multifunction Counter/Timer/Ratemeter 90-260 Vac power 3.78 x 1.89 in (96 x 48 mm) E5-496-E0401 10-30 Vdc power 3.78 x 1.89 in (96 x 48 mm) E5-496-E0402 1 1 Technical Data and Specifications 1 General Specifications Description 1 Specification Supply voltage 10-30 Vdc with reverse polarity protection; 90-260 Vac Current consumption Max. 50 mA 6 VA Display Six-digit red, seven-segment LED display Figure size 0.55 in (14 mm) high Data backup EEPROM Housing Dimension 3.78 x 1.89 in (96 x 48 mm) according to DIN 43 700; RAL 7021 gray Polarity of inputs Programmable, NPN or PNP for all inputs 1 1 1 1 1 Input resistance Approx. 10k ohms Counting frequency 60 kHz, can be damped to 30 Hz depending on operating mode at position display max. 25 kHz 1 Reset time 5 ms Resolution timer Up to 0.001 second 1 High: 0.6 x UB-30 Vdc 1 1 Input switching level DC version (standard version) Low: 0-0.2 x UB (Vdc) AC version 1 High: 12-30 Vdc 1 Low: 0-4 Vdc Voltage supply for sensors 24 Vdc 15%/100 mA at AC versions 1 Accuracy Tachometer <0.1% Timer 1 <50 ppm Ambient temperature -4 to 149F (-20 to 65C) Storage temperature -13 to 167F (-25 to 75C) EMC According to EC EMC directive 89/36/EWG Immunity to interference EN 61 000-6-4/ EN 55011 Class B Emitted interference EN 61-000-6-2 Protection IP65 (from front) Weight Approx. 5.29 oz (150g) 1 1 1 1 1 Note 1 For further specifications, please refer to the user manual. Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-49 1.1 1 1 Counters, Panel Meters, Tachometers and Timers Totalizers Dimensions Approximate Dimensions in Inches (mm) 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter 1 Max. 0.75 (19.0) 3.78 (96.0) 1 1 1 1.89 (48.0) 1.77 x 3.62 (44.9 x 91.9) 1 1 0.61 (15.5) 1 1 0.26 (6.5) 0.16 (4.0) 2.64 (67.1) 1.77 +0.02 (45.0 +0.6) 1 1 3.62 +0.03 (92.0 +0.8) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-50 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Contents Count Controls/Preset Counters Description Page Count Controls/Preset Counters Product Selection Guide . . . . . . . . . . . . . . . . . . . . 1/16 DIN Battery Powered LCD Count Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/16 DIN LCD Preset Counters with Rate and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . President Series (Totalizers). . . . . . . . . . . . . . . . . . Ambassador Series (Totalizers) . . . . . . . . . . . . . . . Ambassador Series (Count Control) . . . . . . . . . . . President Series (Count Control) . . . . . . . . . . . . . . PD-Q and PD-ER Series . . . . . . . . . . . . . . . . . . . . V13-T1-52 V13-T1-53 V13-T1-55 V13-T1-57 V13-T1-60 V13-T1-69 V13-T1-72 V13-T1-64 V13-T1-76 Learn Online 1 1 1 1 1 1 1 1 1 1 1 Product Overview Count controls are counters that provide output signal(s) at preset count value(s). Typical applications include cut-to-length, batching, filling, mixing and dispensing. A variety of count controls in different sizes, display types and feature sets are available from Eaton. Application Description The illustration shows a simple cut-to-length application. The roll of paper is measured using a measuring wheel and rotary contactor (or encoder). Once the desired length is reached, an output signal may be directed to a shear for activation. Following the cutoff, the count control will reset to zero and begin measurement of the next piece. Options such as batch counting, where the number of cut pieces is counted, are also typical of this application. Application Example 1 Rotary Contactor 1 1 1 1 Paper 1 Measuring Wheel 1 Roll 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-51 1.2 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers Product Selection Guide 1 Count Controls/Preset Counters/Totalizers 1 Characteristics E5-148-C Low cost, simple count control 1 Battery operated 1 Two-line display: input and preset values 1 1 Panel Cutout in Inches (mm) Page 1.772 x 1.772 (45 x 45) V13-T1-53 1.772 x 1.772 (45 x 45) V13-T1-55 1.772 x 3.780 (45 x 96) V13-T1-57 2.667 x 2.667 (68 x 68) V13-T1-72 2.667 x 5.433 (68 x 138) V13-T1-64 272 x 1.59 (69 x 40.5) (panel mount model) V13-T1-76 2.667 x 5.433 (68 x 138) V13-T1-119 Easy-to-change preset values E5-648-C Two-line display: counter, timer or tachometer AC or DC power options Wide choice of count modes for pulse inputs, time or frequency 1 Two or four presets 1 1 Eclipse Six-digit, super bright LED display Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls 1 1 1 Ambassador Six-digit, high-visibility, two-line LCD display User-configurable control inputs 1 Highly flexible control/display 1 1 President Bright LED display with 14 mm characters Simple configuration with 14-button tactile keypad 1 Many different versions fit almost any application 1 1 PD-Q and PD-ER Electromechanical pre-set counter Easy setpoint adjustment using pushbuttons 1 Base mount or panel mount 1 1 Fusion 1 Integrated controller combines operator interface, ladder logic and high-speed counting 1 1 1 1 1 1 1 V13-T1-52 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 1/16 DIN Battery Powered LCD Count Control Product Description Features Battery-powered electronic preset counter. Replacement for electromechanical preset counters No power supply necessary (battery operated) Count and reset input electrically separated from counter through optocoupler input range 12-250 Vac/Vdc Two-line LC display count, preset and level of the output Standards and Certifications Screw terminal Data security, through two exchangeable lithium batteries, lifetime minimum eight years Easy programming Counter presets easily via presetting keys allocated to each decade Output: Potential free relay, programmable normally open or normally closed contact cRU(R)us approval CE marked 1 1 1 1 1 1 1 1 Product Selection E5-148-C1400 1 1 1/16 DIN Battery Powered LCD Count Control Description Catalog Number 1 E5-148-C1400 1 Single Preset Count Control Battery power 1.89 x 1.89 in (48 x 48 mm) 1 1 Technical Data and Specifications 1 General Specifications Description Specification Power supply 2 pcs user exchangeable lithium batteries, type 1/2 AA lithium 3.6V Display Two-line LCD display, six digits; 999999 1 1 Figure size 0.28 in (7 mm) or 0.18 in (4.5 mm) high Input Reset, count and keylock inputs 1 Input polarity Bi-directional optocoupler input for the reset count inputs; reset, count and keyboard lock is connected to 3 Vdc 1 Input min. pulse duration Reset input 50 ms; keyboard lock input 15 ms 1 Low <3 Vac/Vdc High 12-250 Vac/Vdc 1 Input switching levels Input frequency Max. 25 Hz Input resistance 110k ohms Output Bistable relay with potential free contact (programmable as normally closed or normally open contact) Max. switching voltage 250 Vac/220 Vdc Max. switching current 2A Max. switching capacity 60 VA/30W Output response time <20 ms, max. 4 Hz Data retention Via two batteries, eight years or 5x106 power operations of the output relay and an ambient temperature of 77F (25C) Ambient temperature 14 to 122F (-10 to 50C) Storage temperature -13 to 140F (-25 to 60C) EMC According to EC EMC directive 89/36/EWG, EN 61 000-6-4/ EN 55011 Class B, EN 61 000-6-2 Protection IP65 (front) Weight Approx. 2.82 oz (80g) Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 1 1 1 1 1 1 1 1 V13-T1-53 1.2 1 1 1 Count Controls/Preset Counters/Totalizers Dimensions Approximate Dimensions in Inches (mm) 1/16 DIN Battery Powered LCD Count Control Max. 0.41 (10.5) 1.89 (48.0) 1 1 Counters, Panel Meters, Tachometers and Timers 123456 7 1.89 (48.0) SQ 1.77 (45) 1 2 3 4 5 6 7 1 1 1 0.63 (16.0) 2.17 (55.0) 1 1 0.12 (3.0) Panel Cut-Out 1.77 x 1.77 (45 x 45) 1 1 2.49 (63.2) Max. 0.37 (9.5) 2.17 (55.0) SQ 1.77 (45) SQ 1.97 (50) 1 1 1 With Front Bezel No. 2 Panel Cut-Out 1.97 x 1.97 (50 x 50) 1 0.63 (16.0) 2.36 (60.0) 1 0.16 (4.0) Max. 0.37 (9.5) 1 1 2.45 (62.2) 2.95 (75.0) 2.48 (63) SQ 1.77 (45) SQ 1.97 (50) 1 1 Flush Bf4, DIN 74 1 With Front Bezel No. 3 Panel Cut-Out 1.97 x 1.97 (50 x 50) 0.63 (16.0) 2.45 (62.2) 0.16 (4.0) 1 1 1 1 1 1 1 1 V13-T1-54 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 1/16 DIN LCD Preset Counters with Rate and Time Product Description Features AC or DC powered preset counters that can function as timer or tachometer/ ratemeter. Two-line display with green backlight (E5-648-C2421 and E5-648-C2422) or multi-color red/green LED backlighting (E5-648C4461 and E5-648-C4462) Programmable as preset counter, batch counter or totalizer Power supply: 90-260 Vac or 10-30 Vdc Standards and Certifications Direct input of the presets via front keys or Teach-In input Relay outputs Scaling by multiplication and division factors 0.0001 to 99.999 Two preset values, two outputs Four preset values, four outputs cRU(R)us approval CE marked 1 1 1 1 1 1 1/16 DIN Two-Line LCD Count Control Catalog Number 1 90-260 Vac power 1.89 x 1.89 in (48 x 48 mm) E5-648-C2421 1 10-30 Vdc power 1.89 x 1.89 in (48 x 48 mm) E5-648-C2422 1 90-260 Vac power 1.89 x 1.89 in (48 x 48 mm) E5-648-C4461 10-30 Vdc power 1.89 x 1.89 in (48 x 48 mm) E5-648-C4462 1 1 Description Two Preset LCD Count Control with Backlighting Four Preset LCD Count Control with Multi-Color Display 1 1 Technical Data and Specifications 1 General Specifications Description Specification Power supply 10-30 Vdc external fuse protection Display Two-line LCD display, six digits with programmable decimal point Figure size 0.35 in (9 mm) high upper line 1 1 90-260 Vac max. 8 VA external fuse protection 1 0.28 in (7 mm) high lower line Count inputs Two count inputs (A and B), programmable for count/count direction, up/up, up/down, quadrature, quad2, quad4, A/B or (A-B)/A x 100% Input polarity Programmable for all inputs in common NPN/PNP Input resistance Approx. 5k ohms Count frequency Max. 55 kHz with programmable filter for 30 Hz (see manual for details) Input min. pulse duration 10 ms for control inputs/1 ms for reset input 1 1 1 1 Switching levels 1 DC supply voltage High 0.6 x UB-30 Vdc Low 0-0.2 x UB (Vdc) 1 AC supply voltage High 12-30 Vdc Low 0-4 Vdc Pulse shape 1 1 Product Selection E5-648-C_ 1 1 1 Variable (Schmitt-Trigger characteristics) 1 Note 1 Not a stocked product, contact Eaton Care for assistance. 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-55 1.2 1 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers General Specifications, continued Description Specification Output 1 Relay Programmable as normally open or normally closed Switching voltage max. 250 Vac/110 Vdc 1 Switching current max. 3A Vac/3A Vdc Switching current at DC min. 30 mA Vdc 1 Switching power at DC 90W Switching power at AC max. 750 VA 1 Output 2 Relay Relay with changeover/Form C contact 1 Switching voltage max. 250 Vac/110 Vdc 1 Switching current max. 3A Vac/3A Vdc Switching current at DC min. 30 mA Vdc 1 Switching power at DC 90W Switching power at AC max. 750 VA 1 Reaction time of the outputs Approximately 10 ms 1 1 Data retention Min. 10 years or 1 million memory cycles Sensor supply voltage AC powered unit 24 Vdc 15%, 80 mA DC powered unit Max. 80 mA, DC voltage is connected through 1 Ambient operating temperature -4 to 149F (-20 to +65C) Storage temperature -13 to 167F (-25 to 75C) 1 EMC 1 1 1 1 1 Emitted interference EN 55011 Class B Immunity to interference EN 61000-6-2 Protection IP65 (front) Weight Approx. 4.4 oz (125g) Dimensions Approximate Dimensions in mm [Inches] 1/16 DIN Two-Line LCD Count Control 1 Max. 10.5 [0.413] 1 48 [1.89] 45+06 [1.77 +0.024] 1 1 1 48 [1.89] 1 45 [1.77] 45+06 [1.77 +0.024] 15.5 [0.61] 1 1 Panel Cut-Out 4.25 [0.167] 91 [3.583] 1 7 [0.276] 1 1 V13-T1-56 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Eclipse Series Product Description Features High visibility LED interface available with a variety of output options 1/8 DIN cutout NEMA 4X front panel Universal AC power supply (85-265 Vac) DC power models (9-30 Vdc) Standards and Certifications Removable screw terminals Short depth: 3.6 in (91 mm) Front panel programming UL and cUL listed CE marked Eclipse Series 1 1 1 1 Product Selection 57700481 1 1 LED Count Control, Six-Digit Description Catalog Number Relay out, 9-30 Vdc power 57700481 Relay out, 85-265 Vac power 57701481 Relay and analog out, 9-30 Vdc power 57700483 Relay and analog out, 85-265 Vac power 57701483 Relay and RS-485 out, 9-30 Vdc power 57700485 Relay and RS-485 out, 85-265 Vac power 57701485 Relay, analog and RS-485 out, 9-30 Vdc power 57700487 Relay, analog and RS-485 out, 85-265 Vac power 57701487 1 1 1 1 1 1 Totalizers Description Catalog Number 9-30 Vdc power 57700480 Analog out, 9-30 Vdc power 57700482 85-265 Vac power 57701480 Analog out, 85-265 Vac power 57701482 1 1 1 1 1 Technical Data and Specifications General Specifications Description 1 Specification 1 Mechanical Cutout dimensions 3.62 in W x 1.77 in H (92 mm x 45 mm) DIN standard Outline dimensions 4.04 in W x 2.19 in H x 3.87 in D (103 mm x 56 mm x 98 mm) 3.60 in (92 mm) maximum depth in panel Enclosure Plastic with polyester front label Connectors Up to six depluggable terminal blocks 1 1 1 Environmental Operating environment Indoor use to 2000 meters 1 Operating 32 to 122F (0 to 50C) Storage -4 to 158F (-20 to 70C) 1 Temperature Humidity 0 to 85% RH, non-condensing Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave EMC Immunity to EN 50082-2 (heavy industrial) 1 1 1 Emissions to EN 50081-2 (heavy industrial) Front panel NEMA 4X when mounted with gasket provided CE EMC immunity and emissions requirements Met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution degree 2 Overvoltage Category II 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-57 1.2 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers General Specifications, continued Description Specification 1 Input Power 1 Input power 85-295 Vac, 47-63 Hz, 20V A External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V) Isolation dielectric strength 2300 Vac 1 1 1 1 1 AC powered models (57701-4XX) DC powered models (57700-4XX) Input power 9-30 Vdc, 12V A External fuse 2.0A, 50 Vdc, time delay (T2A, 50V) Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal outputs and relays, 500 Vac to RS-485 and analog outputs Human Interface Display +6, -5 digits 1 Type 0.56 in (14.2 mm) high, seven segment, red LED 1 Memory type EEPROM, no batteries required 1 Duration 100 years Count Signal Input Data Retention 1 Sensor type Sink or source, DIP switch selectable Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground 1 Thresholds 1 High 3.5-28 Vdc Low 0-1.9 Vdc, for single ended signals Magnetic pickup range 200 mV p-p to 65V rms into 34.9k ohms 1 Slow response 200 Hz max. (DIP switch 2 and/or 5 ON) 1 Count mode 1 1 1 1 Fast response A or B Add/add, add/subtract, add w/Inh 8250/8250 Fast response Count mode A and B Add/add, add/subtract, add w/Inh 3000/3000 Quad x1, quad x2 3250 Quad x4 2000 Control Inputs 1 Sensor type Sink only Input impedance 4.75k ohms to +5 Vdc 1 Thresholds 1 High 3.5 to 28 Vdc Low 0-1.9 Vdc Response 25 ms maximum (5V signal) 1 Accessory Power Output 1 Voltage 12 Vdc +10%/-13% Current 75 mA max. Protection Short-circuit protected 1 1 1 1 1 V13-T1-58 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Dimensions 1 Approximate Dimensions in Inches (mm) 1 Eclipse Series 1 1 2.19 (55.6) 1 1.772 0.02 (45 0.6) PGM 1 4.04 (102.6) 1 3.622 0.03 (92.00 0.8) Panel Cutout Max. Panel Thickness 0.190 (4.83) 1 1 1 1 3.63 (92.2) 1 3.31 (84.1) 1 1 0.27 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-59 1.2 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers President Series (Totalizers) Product Description Features Eaton's President Series totalizers are heavy-duty electronic totalizers with two available sizes. Standards and Certifications Eight-digit, LED display, 0.56 in (14 mm) Programmable decimal point and count and rate scaling 15 Vdc at 100 mA output power Rear panel screw terminals NEMA 4 front panel 1 1 Product Selection 1 President Series President Series Totalizers 1 Description Catalog Number 1 115/230 Vac, LED red display 58811400 115/230 Vac, LED red display, 1/Tau ratemeter 58815400 1 115 Vac, seven-digit LED red display, basic pulse count 57810400 115/230 Vac, LED red display 58810400 1 Feet/inches totalizer 57810402 1 1 1 1 Technical Data and Specifications General Specifications Description Specification Power Requirements 1 AC operation 115/230 Vac (+10%, -20%) 47-63 Hz DC operation 11-28 Vdc 1 Power DC power output 18 watts 1 1 1 15 Vdc (+1, -2). 150 mA if powered from AC or less than 24 Vdc 100 mA if powered from 24 Vdc or greater Environment 1 Operating temperature 32 to 130F (0 to 55C) Storage temperature -40 to 160F (-40 to 70C) 1 Operating humidity 85% non-condensing relative Physical 1 Memory types 1 Note 1 DC power output is only regulated if unit is powered by AC or greater than 18.5 Vdc. PROM, RAM, non-volatile NVRAM 1 1 1 1 1 1 1 V13-T1-60 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL listed CSA marked CE marked Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 General Specifications, continued Description 1 Specification 1 Counter Count range Eight digits (0 to 99,999,999) with rollover Offset range Eight digits (0 to 99,999,999) (offset is used to reset to a non-zero number) Count modes Count with add and subtract inputs 1 1 Count with up/down direction input (hardware doubling for above modes is provided) 1 Count with count inhibit input 1 Quadrature Doubled quadrature 1 Count speed (scale factor of 1.0000 assumed) 58811400 and 58815400 0 to 7,500 counts per second (CPS) with shaft encoders or solid-state sensors 1 0 to 3,750 CPS when hardware doubling is implemented or when quadrature shaft encoders are used 1 0 to 150 CPS when low frequency is selected 57810400, 58810400 and 57810-402 0 to 10,000 counts per second (CPS) with shaft encoders or solid-state sensors with internal pull-up resistor 1 0 to 7,500 CPS minimum for sensors with open collector transistor output 1 0 to 5,000 CPS when hardware doubling is implemented Count Input Ratings 1 1 Input voltage High state (logical "1", sensor off or contact open) 10.5-24.5 Vdc when control is powered by AC line 1 7.0-24.5 Vdc when control is powered by 11 Vdc 1 11.0-24.5 Vdc when control is powered by 16 Vdc Low state (logical "0", sensor on or contact closed) 0-4.5 Vdc when control is powered by AC line 1 0-3.3 Vdc when control is powered by 11 Vdc 0-4.8 Vdc when control is powered by 16 Vdc Input impedance 1 6800 ohms to 15 Vdc when control is powered by AC line 20 mA peak, 3 mA steady state 1 High speed (low speed jumpers not connected) 1 6800 ohms to 10 Vdc when control is powered by DC supply Input current Input response High state (logical "1", sensor off or contact open) 1 110 S minimum at 15 Vdc (6,800 ohms to +DC) 160 S minimum at 13.5 Vdc (50,000 ohms to +DC) High state (logical "1", sensor off or contact open) 1 Low speed (low speed jumpers connected) 5.5 ms minimum at 15 Vdc (6,800 ohms to +DC) 1 7.5 ms minimum at 13.5 Vdc (50,000 ohms to +DC) Low state (logical "0", sensor on or contact closed) 1 High speed (low speed jumpers not connected) 20 S minimum at 0.1 Vdc (0 ohms to DC common) 1 45 S minimum at 1.5 Vdc (500 ohms to DC common) Low state (logical "0", sensor on or contact closed) Low speed (low speed jumpers connected) 1 1.0 ms minimum at 0.1 Vdc (0 ohms to DC common) 1 2.0 ms minimum at 1.5 Vdc (500 ohms to DC common) Note 1 The count inputs are designed to work with current sinking sensors (open-collector NPN transistor output with or without passive pull-up resistor) or contact closures to DC common. 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-61 1.2 1 Description Scale Factor 1 Control Inputs 1 1 1 1 1 1 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 1 Counters, Panel Meters, Tachometers and Timers Specification Range Five digits (0.0001 to 9.9999) Input voltage High state (logical "1", contact open) 15 Vdc maximum Low state (logical "0", contact closed) 1.2 Vdc maximum Input impedance 4.75k ohms to +5 Vdc Threshold High +3.5 to +22 Vdc Low +0.0 to +1.0 Vdc Response time 1 Min. high 5.3 ms Min. low 3.9 ms Diagnostic Modes Diagnostic modes ROM checksum RAM bit test 1 NVRAM read/write test 1 NVRAM checksum NVRAM store test Watchdog timer 1 1 1 1 Display and LED indicator test Counter Operating Modes Reset Reset to zero Reset to offset value Maintained Reset Momentary Reset 1 Communications 1 Speed 110, 300 and 1200 baud, user selectable 1 Data type Standard ASCII code Format Start bit, 7 ASCII data bits, parity bit, one or two stop bits (even parity for serial data output, no parity for serial data input) 1 Interface type Information transmitted Scale factor Information received 1 Print request Offset value 1 1 Count value Offset value 1 1 Dual port 20 mA current loop Scale factor Note 1 The reset and unlatch signals will both occur in less than 200 microseconds after the input signal is detected. The start of the print will occur within 2 milliseconds after the input is detected if the unit is not counting. 1 1 1 1 1 V13-T1-62 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Dimensions Approximate Dimensions in Inches (mm) 1 Standard President Size 1 2.677 0.03 (68 0.7) 1 0.735 0.02 (18.7 0.5) 5.433 0.04 (138 1.0) 1 Recommended Panel Cutout 1 2.62 0.025 (66.67 0.6) 1 0.95 0.04 (24.1 1.0) 5.53 0.015 (140.5 0.4) 5.78 0.02 (146.8 0.5) 1 1 5.91 0.03 (150.1 0.8) 1 Offset Count 1 2 3 4 5 6 7 8 9 3.04 0.015 (77.2 0.4) USE EXTERNAL FUSE! Preset 1 1 2 3 4 5 Count Function 6 7 8 9 0 Reset Enter 1 10 11 12 13 14 15 16 17 18 IN1 IN2 1 IN OUT K1 115/230V~ K2 50/60 Hz + + 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 5.38 0.02 (136.7 0.5) 5.80 0.015 (147.3 0.4) 1 6.25 0.02 (158 0.5) 1 Compact President Size 1 5.43 0.04 (138 1.0) 1.77 0.025 (45 0.6) 1 1.74 0.01 (44.20 0.25) Recommended Panel Cutout 1 1 5.53 0.015 (140.5 0.4) 0.17 0.01 (4.3 0.24) 1 1 1 2.16 0.015 (54.9 0.4) Reset 2 3 4 5 6 SWA 7 8 1 2 3 4 1 5 SWB IN OUT IN1 115/230V~ IN2 + + 50/60 Hz P R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 5.80 0.015 (147.3 0.4) 1 1 5.38 0.015 (136.7 0.4) 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-63 1.2 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers President Series (Count Control) Product Description Features Eaton's President Series features an easy-to-read LED and a simple preset input by means of the large keypad. 1 1 1 1 Standards and Certifications Five- or six-digit, LED display, 0.56 in (14 mm) 1, 2 or 3 presets 15 Vdc at 100 mA output power Rear panel screw terminals 20 mA current loop communications 2 Form C relays Tactile keypad NEMA 4 front panel UL listed CSA marked CE marked Product Selection 58831400 President Series Count Control Features Description Totalizer Batch Counter Rate Scaler Crop-Cut Main Counter Presets Digits Catalog Number 1 120 Vac, no communications -- -- -- -- 1 1 5 57820400 Single preset -- -- -- -- -- 1 1 5 58821400 1 Single preset with rate -- -- -- 1 1 5 58825400 Dual preset -- -- -- -- 1 2 5 58831400 1 1 1 Dual preset with batch -- -- 1 2 6 58841400 Dual preset with totalizer or batch counter 1 1 -- 1 2 6 58851400 Three presets with floating pre-warn -- -- -- -- 1 3 6 58861400 1 Main counter, batch and totalizer presets 2 2 -- 3 1 ea. 6 58827400 Two independent count registers 3 3 -- 3 1 ea. 6 58827410 1 High-speed count control--30 kHz max. -- -- 1 2 6 58867400 President position controller 1 For more details, see Page V13-T1-124 58868400 Notes 1 These models have, in addition to the main count register, a register that may be configured to be used as either a totalizer or single preset batch counter. These two functions are mutually exclusive. 2 The model 58827-400 has both a totalizer and a batch counter, each with a single preset. In addition, the batch counter may be configured as an additional totalizer with control instead of batch counter. 3 The model 58827-410 has two completely independent count input channels feeding two independent, single preset count registers. In addition, a third single preset register may be used as either a totalizer or a batch counter for one or both of the two main counters. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-64 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1.2 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers Technical Data and Specifications 1 President Series--Count Control 1 Description Model 57820400 57820401 58821400 AC power requirements 120V 10% 240V 10% 120V/240V +10%/-20%, 47-63 Hz DC power requirements 11-30 Vdc 11-30 Vdc 11-28 Vdc Power consumption 8 watts max. 8 watts max. 18 watts max. DC power output 1 15 Vdc +1/-2 at 85 mA max. 58831400 1 11-28 Vdc 11-28 Vdc 18 watts max. 18 watts max. 1 58825400 1 15 Vdc +1/-2; 150 mA if powered from AC or less than 24 Vdc, 100 mA if powered from 24 Vdc or greater 1 Operating temperature 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) Operating humidity 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing Storage temperature -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) Front panel rating NEMA 4 rating when mounted with gasket provided 1 Main counter scaler range N/A N/A 5 Digits (0.0001 to 9.9999) 5 Digits (0.0001 to 9.9999) 5 Digits (0.0001 to 9.9999) Count input frequency 10 kHz (5 kHz in quadrature) 10 kHz (5 kHz in quadrature) See table on Page V13-T1-66 See table on Page V13-T1-67 See table on Page V13-T1-66 1 Count input impedance 6.8k ohms to 15 Vdc when control is powered by AC line; 6.8k ohms to 10 Vdc when control is powered by DC line Control input threshold High 10.5 to 24.5 Vdc; Low 0.0 to 4.5 Vdc when powered by AC 4.5k ohms to +5 Vdc 1 Control input impedance 4.5k ohms to +5 Vdc Control input response time Min. high 5.3 ms; min. low 3.9 ms Relay contact output ratings SPDT Form C; 10 amps resistive at 24 Vdc or 230 Vac; 1/3 hp at 115 Vac or 230 Vac; 150 Vdc max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating Transistor output ratings Open collector NPN transistor with Zener diode transient surge protection; 30 Vdc max. load; 300 mA max. per transistor; 480 mA total for all transistors. Use 5 mA per relay coil when calculating total transistor current Communications N/A N/A 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc Model 58841400 58851400 1 1 1 1 Dual port 20 mA current loop, standard ASCII code 1 President Series--Count Control, continued Description 1 58827400 58827410 58867400 1 1 AC power requirements 120V/240V +10%/-20%, 47-63 Hz DC power requirements 11-28 Vdc 11-28 Vdc 11-28 Vdc 11-28 Vdc 11-28 Vdc Power consumption 18 watts max. 18 watts max. 18 watts max. 18 watts max. 18 watts max. DC power output 1 15 Vdc +1/-2; 150 mA if powered from AC or less than 24 Vdc, 100 mA if powered from 24 Vdc or greater Operating temperature 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) 32 to 130F (0 to 55C) -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) -10 to 160F (-40 to 71C) 1 1 1 1 Operating humidity 85% relative, non-condensing Storage temperature -10 to 160F (-40 to 71C) Front panel rating NEMA 4 rating when mounted with gasket provided Main counter scaler range 5 digits (0.0001 to 9.9999) 5 digits (0.0001 to 9.9999) 5 digits (0.0001 to 9.9999) 5 digits (0.0001 to 9.9999) 6 digits (0.00001 to 9.99999) 1 Count input frequency See table on Page V13-T1-66 See table on Page V13-T1-66 See table on Page V13-T1-66 See table on Page V13-T1-67 See table on Page V13-T1-67 Count input impedance 6.8k ohms to 15 Vdc when control is powered by AC line; 6.8k ohms to 10 Vdc when control is powered by DC line 1 Control input threshold High 10.5 to 24.5 Vdc; Low 0.0 to 4.5 Vdc when powered by AC 4.5k ohms to +5 Vdc 1 Control input impedance 4.5k ohms to +5 Vdc Control input response time Min. high 5.3 ms; min. low 3.9 ms 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc Relay contact output ratings SPDT Form C; 10 amps resistive at 24 Vdc or 230 Vac; 1/3 hp at 115 Vac or 230 Vac; 150 Vdc max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating Transistor output ratings Open collector NPN transistor with Zener diode transient surge protection; 30 Vdc max. load; 300 mA max. per transistor; 480 mA total for all transistors. Use 5 mA per relay coil when calculating total transistor current Communications Dual port 20 mA current loop, standard ASCII code 4.5k ohms to +5 Vdc 1 1 1 1 1 Note 1 DC power output is only regulated if unit is powered by AC or greater than 18.5 Vdc. 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-65 1.2 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1 58821400 Count Frequency 1 Scale Factor Nominal Count Quadrature and/or Doubled Count <1.0000 6,250 3,125 1.0000 7,500 3,750 1 1.9999 5,000 2,500 2.0000 6,250 3,125 1 9.0000 2,500 1,250 9.9999 2,000 1,000 1 Count Speed (Pulses per Second) 1 1 58831400, 58841400, 58861400 Count Frequency 1 Scale Factor Nominal Count Quadrature and/or Doubled Count <1.0000 5,000 2,500 1.0000 7,500 3,750 1 1.9999 4,000 2,000 2.0000 6,000 3,000 1 9.0000 2,000 1,000 9.9999 1,500 750 1 Count Speed (Pulses per Second) 1 1 58851400 Count Frequency Count Speed (Pulses per Second) 1 1 Function 61 value = "0" Scale Factor Nominal Count Function 61 value = "1" Quadrature and/or Doubled Count Nominal Count Quadrature and/or Doubled Count <1.0000 5,000 2,500 3,500 1,750 1.0000 7,500 3,750 4,500 2,250 1 1.9999 4,000 2,000 2,400 1,200 2.0000 6,000 3,000 3,600 1,800 1 9.0000 2,000 1,000 1,100 550 9.9999 1,500 750 1,000 500 1 1 1 58827400 Count Frequency 1 Scale Factor Count Up Count Down Quadrature 1 0.999 4,000 2,250 2,000 1.000 5,000 3,500 3,500 1 1.999 3,500 2,000 1,250 2.000 4,000 3,000 2,750 1 9.000 1,500 1,500 1,500 9.999 1,250 1,000 1,000 1 Count Speed (Pulses per Second) 1 1 1 1 1 V13-T1-66 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 58867400 Count Frequency 1 1 Count Speed (Pulses per Second) Count Mode X1 X2 X3 High speed 30,000 15,000 7,500 Low speed 200 200 200 1 1 1 58827410 Count Frequency 1 Count Speed (Pulses per Second) Typical Combinations of Features 2 Sample Scale Factor C1 = ON C2 = OFF C3 = OFF RM = OFF C1 = ON C2 = ON C3 = OFF RM = OFF C1 = ON C2 = ON C3 = ON RM = OFF C1 = ON C2 = ON C3 = OFF RM = ON 1 C1 = ON C2 = ON C3 = ON RM = ON 0.0001-0.9999 6,000 3,000 2,300 2,600 2,000 1.0000 9,000 4,500 3,500 4,000 3,000 5.0000 4,500 2,250 1,000 2,000 750 9.9999 1,500 1,000 500 750 550 1 1 1 1 1 58825400 Count Frequency Count Speed (Pulses per Second) Scale Factor Nominal Count 1 Quadrature and/or Doubled Count <1.0000 4,200 2,100 1.0000 7,500 3,750 1.9999 3,450 1,720 2.0000 6,250 3,120 9.0000 2,500 1,250 9.9999 1,800 900 1 1 1 1 Notes 1 The maximum count input frequency depends only on the selected count mode (doubled or quadrature x4). The maximum input frequencies shown are with square wave (50% duty cycle) input. 2 C1: Counter #1; C2: Counter #2; C3: Counter #3; RM: Ratemeter. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-67 1.2 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers Dimensions Approximate Dimensions in Inches (mm) President Series Count Control 1 5.433 0.04 (138 1.0) 1 1 1 2.677 0.03 (68 0.7) 0.735 0.02 (18.7 0.5) 2.62 0.025 (66.67 0.6) Recommended Panel Cutout 0.95 0.04 (24.1 1.0) 1 1 5.53 0.015 (140.5 0.4) 5.78 0.02 (146.8 0.5) 5.91 0.03 (150.1 0.8) 1 1 5.80 0.015 (147.3 0.4) 1 1 1 1 2 3 4 5 6 7 8 9 Preset Count 10 11 12 13 14 15 16 17 18 IN1 IN2 USE Preset 1 1 1 6 1 1 Preset 2 2 7 3 8 4 9 5 0 Count Function 3.04 0.015 (77.2 0.4) K1 FUSE! Reset Enter 6.25 0.02 (158 0.5) 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-68 EXTERNAL IN OUT K2 K1 115/230V~ 50/60 Hz + + 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 5.38 0.02 (136.7 0.5) 1 K2 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Ambassador Series (Totalizers) Product Description Features Eaton's Ambassador Series is our most noise-immune totalizer available. Various counting modes can be set by the user. Standards and Certifications AC/DC powered, two-line LCD display Eight-digit totalizer 1/Tau ratemeter Totalizer and ratemeter scaling Four user-configurable control inputs Two solid-state outputs RS-485 serial communications UL listed CE marked 1 1 1 Ambassador Series Totalizers Description Catalog Number 10-15 Vdc LCD 57600400 115 Vac LCD 57601400 230 Vac LCD 57602400 1 1 Product Selection Ambassador Series 1 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description 1 Specification Power Input AC operation 1 115 Vac (15%) std., 50 to 60 Hz, 7W 230 Vac (15%) opt., 50 to 60 Hz, 7W DC operation 10-15 Vdc opt., 300 mA maximum DC power output 12 Vdc (25%), 100 mA maximum (includes all line and load variations) 1 1 Environmental Operating temperature 32 to 131F (0 to 55C) Storage temperature -4 to 158F (-20 to 70C) 1 1 Operating humidity 85% relative, non-condensing Rating NEMA 4 when mounted with gasket provided 1 Type Bi-directional Digits Eight 1 Totalizer Scaler range 0.00001 to 9.99999 Decimal point Five positions, programmable 1 1 Totalizer Count Speeds 1 Maximum speed--solid-state (high speed) 1 Mode Input A/Input B Add/sub 20 kHz Add/add 20 kHz Count/direction 15 kHz Count x 2/direction 7.5 kHz Quadrature 6.5 kHz Quadrature x 2 6.5 kHz 1 Mode Input A/Input B Add/sub 40 kHz 1 1 1 1 Maximum speed--contact (low speed) Add/add 40 kHz Count/direction 0 kHz 1 1 Note 1 The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input. Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 V13-T1-69 1.2 1 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers General Specifications, continued Description Specification Count Inputs Sink Impedance 4.6k ohms to +5 Vdc 1 Voltage High 3.5 to 34.0 Vdc 1 Low 0.0 to 1.9 Vdc 1 1 Source (high) Impedance High 3.5 to 17.0 Vdc (100% duty cycle) Low 0.0 to 1.9 Vdc 1 Source (low) 1 DC voltage 1 1 1 1 1 2.3k ohms to common Voltage Impedance 2.3k ohms to common High 0.6 to 17.0 Vdc Low -17.0 to -0.6 Vdc AC voltage 17 Vac (48V peak-peak) maximum Control Inputs Impedance 4.7k ohms to +5 Vdc Voltage High +3.7 to +24 Vdc Low 0.0 to 0.9 Vdc Response Minimum low 15 ms, minimum high 15 ms 1 Transistor Outputs (2) Type NPN open collector with transient protection 1 Maximum voltage (OFF state) 30 Vdc Maximum current (ON state) 200 mA at 1.3 Vdc 1 Communication 1 Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit 1 Protocol Opto-22 compatible Speed 300, 1200, 2400, 4800, 9600 and 19200 baud 1 Parity Odd, even, none (space transmitted, ignore received) Type RS-485 Count Accuracy 1 Operating within specifications 1 Type 1/Tau 1 Digits Six Scaler range 0.00001 to 99999 1 Decimal point Five positions, programmable 1 Accuracy 0.015% of reading Update time 1 second, fixed 1 Zero time 10 seconds, fixed 1 Type Dual depluggable screw terminal strips Conductor size 14-22 AWG (2.1-0.38 mm2), 600V, solid, stranded or fused (preferred) 100% when operated within the specified count speeds and count signal high and low times Rate Indicator Connections 1 1 1 V13-T1-70 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Dimensions Approximate Dimensions in Inches (mm) 1 Ambassador Series Totalizer 1 1 C 123456 P1 10000 RST CLR RUN PGM PRNT EXIT ENT SEL 1 1 2.946 0.015 (74.83 0.38) 1 * 1 2.946 0.015 (74.83 0.38) 1 5.60 0.03 (142.24 0.76) 1 Gasket 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 1 Panel Cutout Max. Panel Thickness 0.50 (12.7) 1 2.677 0.028 (68.00 0.70) 1 1 1 2.677 0.028 (68.00 0.70) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-71 1.2 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers Ambassador Series (Count Control) Product Description Features Eaton's Ambassador Series provides up to four presets in one of the most noiseimmune packages available. 1 1 1 Product Selection 1 57601401 AC/DC powered, two-line LCD display Eight-digit totalizer 1/Tau ratemeter Totalizer and ratemeter scaling Four user-configurable control inputs Standards and Certifications Up to two output relays Two solid-state outputs RS-485 serial communications Feet/inches control available Ambassador Series Count Control Description Catalog Number Single preset with rate, 115 Vac 57601401 1 Single preset with rate, batch and totalizer, 115 Vac 57601402 Dual preset with rate, 115 Vac 57601403 1 Dual preset with rate, batch and totalizer, 115 Vac 57601404 1 Four preset with rate, batch and totalizer, 10-15 Vdc 57600405 Four preset with rate, batch and totalizer, 115 Vac 57601405 1 Four preset with rate, batch and totalizer, 230 Vac 57602405 Feet/inches control, 115 Vac 57601415 1 Feet/inches control, 230 Vac 57602415 1 1 1 Technical Data and Specifications General Specifications 1 Description 1 AC operation 1 DC operation 1 DC operation 1 1 Specification Power Input 115 Vac (15%) std., 50 to 60 Hz, 7W 230 Vac (15%) opt., 50 to 60 Hz, 7W 10-15 Vdc opt., 300 mA maximum Power Output 12 Vdc (25%), 100 mA maximum (includes all line and load variations) Environmental Operating temperature 32 to 131F (0 to 55C) Storage temperature -4 to 158F (-20 to 70C) Operating humidity 85% relative, non-condensing 1 NEMA 4 rating When mounted with gasket provided 1 Type Bi-directional Digits Six 1 Presets Varies by model Reset modes Auto or manual reset to zero or preset 1 Scaler range 0.00001 to 9.99999 Decimal point Five positions (six on four-preset models) 1 Output latency See table on Page V13-T1-74 1 Type Increment with main counter recycle or final preset signal Digits Six Presets One Output latency <1 ms 1 1 Main Counter Batch Counter V13-T1-72 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL listed CE marked Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 General Specifications, continued Specification 1 Type Bi-directional, same or opposite of main counter 1 Digits Eight Scaler Shared with main counter Decimal point Tracks main counter Description Totalizer 1 1 Count Input Speeds 1 See tables on Page V13-T1-74 Count Inputs Sink Impedance 1 4.6k ohms to +5 Vdc 1 Voltage High 3.5 to 34.0 Vdc Low 0.0 to 1.9 Vdc 1 2.3k ohms to common 1 3.5 to 17.0 Vdc (100% duty cycle) 1 Source (high) Impedance Voltage High Low Source (low) Impedance DC voltage High Low AC voltage 0.0 to 1.9 Vdc 1 2.3k ohms to common 1 0.6 to 17.0 Vdc 1 -17.0 to -0.6 Vdc 17 Vac (48V peak-peak) maximum 1 Control Inputs Impedance 4.7k ohms to +5 Vdc Voltage High 1 +3.7 to +24 Vdc 1 Low 0.0 to 0.9 Vdc Response Minimum low 15 ms, minimum high 15 ms 1 Type SPDT contacts UL ratings 250 Vac, 360V A pilot duty 1 Type NPN open collector with transient protection 1 Maximum voltage (OFF state) 30 Vdc Maximum current (ON state) 200 mA at 1.3 Vdc Relay Outputs Transistor Outputs (2) 1 1 Communication Type RS-485 Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit Protocol Opto-22 compatible Speed 300, 1200, 2400, 4800, 9600 and 19200 baud Parity Odd, even, none (space transmitted, ignore received) 1 1 1 Rate Indicator (Not available on models 57601-415 and 57601-485) Type 1/Tau Digits Six Presets Two Scaler range 0.00001 to 99999 Decimal point Five positions, programmable Accuracy 0.015% of reading Update time See table on Page V13-T1-74 Zero time See table on Page V13-T1-74 1 1 1 1 1 Connections Type Dual depluggable screw terminal strips Conductor size 14-22 AWG (2.1-0.38 mm2), 600V, solid, stranded, or fused (preferred) Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 V13-T1-73 1.2 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers Output Latency for Ambassador Control Style Number Output Latency 1 5760X401 0.7 to 2 ms 1 5760X402 0.7 to 2 ms 5760X403 0.7 to 2.7 ms 1 5760X404 0.7 to 2.7 ms 5760X405 <1 ms 1 5760X415 <1 ms 1 Rate Indicator Specs for Ambassador Control 1 Style Number Update Time Zero Time 1 5760X401 1 second, fixed 10 seconds, fixed 5760X402 1 second, fixed 10 seconds, fixed 1 5760X403 1 second, fixed 10 seconds, fixed 5760X40 1 second, fixed 10 seconds, fixed 1 5760X405 0.1 to 99.9 seconds, programmable 0.1 to 99.9 seconds, programmable 5760X415 0.1 to 999.9 seconds, programmable 0.1 to 999.9 seconds, programmable 1 1 Ambassador Count Input Speeds--5760X405, 5760X415 1 1 Solid-State A or B A-B 8250/8250 3000/3000 1 A+B 8250/8250 4000/4000 -A + B 8000/8000 3000/3000 1 A, B Dir 8000/40 -- 1 2A, B Dir 4500/40 -- A, B Rst 8250 -- 1 Quad x 1 -- 3250 Quad x 2 -- 3250 1 Quad x 4 -- 2000 Tot A/Cnt B 14000/9000 6500/6500 Tot + Cnt B 16000/8500 6500/6500 1 1 1 A and B Ambassador Count Input Speeds--5760X401, 5760X402, 5760X403, 5760X404 Maximum Speed 2 Mode Input A/B Solid-State (High Speed) Add/sub 20 kHz 40 kHz Add/add 20 kHz 40 kHz 1 Count/direction 15 kHz 40 kHz Count x 2/direction 7.5 kHz -- 1 Quadrature 6.5 kHz -- Quadrature x 2 6.5 kHz -- 1 1 1 1 Contact (Low Speed) Notes 1 Contact inputs = 40 Hz; B direction inputs = 40 Hz and B reset input = 10 S min. low. Input A not active on ft/in control. 2 The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input. 1 1 1 V13-T1-74 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Dimensions 1 Approximate Dimensions in Inches (mm) 1 Ambassador Series C 123456 P1 10000 RST CLR RUN PGM PRNT EXIT ENT SEL 1 1 1 2.946 0.015 (74.83 0.38) 1 * 1 1 5.60 0.03 (142.24 0.76) 2.946 0.015 (74.83 0.38) 1 Gasket 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 1 Panel Cutout Max. Panel Thickness 0.50 (12.7) 1 2.677 0.028 (68.00 0.70) 1 1 1 2.677 0.028 (68.00 0.70) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-75 1.2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers PD-Q and PD-ER Series Product Description The PD-Q Series is a fivedigit, true subtracting electric predetermined counter that features pushbutton operation of both predetermined count settings and reset. The predetermined count is set by holding the RESET button in and then depressing the easy to operate pushbutton selectors under each digit. The unit subtracts, one count for each contact closure or impulse and actuates a 4 ampere, 250 Vac switch when zero is reached. Features The output signal from this switch can be used to halt or change the flow of items being counted, and/or operate other electrical apparatus. The counter returns to the predetermined number when the RESET button is depressed and it is immediately ready to control the next lot or batch. Standards and Certifications Easy setpoint adjustment Available in base mount or panel mount configurations The PD-ER Series is identical to the PD-Q Series, except that it has electric reset (ER) for remote operation, allowing either local or remote use. Product Selection When Ordering Specify When ordering PD-Q and PD-ER Series Predetermined Counters, specify catalog numbers according to the features selected. 5-Y-41433-*-PD-Q PD-Q and PD-ER Series Predetermined Counters Voltage Mounting Wire Leads Catalog Number 12 Vdc Panel Rear 5-Y-41433-401-PD-Q 41433401 24 Vdc Panel Rear 5-Y-41433-402-PD-Q 41433402 1 1 120 Vac Panel Rear 5-Y-41433-406-PD-Q 41433406 1 1 240 Vac Panel Rear 5-Y-41433-407-PD-Q 41433407 24 Vac Panel Rear 5-Y-41433-408-PD-Q 41433408 24 Vdc Base Rear 5-Y-41469-402-PD-Q 41469402 1 120 Vac Base Rear 5-Y-41469-406-PD-Q 41469406 1 1 1 1 Order Number 240 Vac Base Rear 5-Y-41469-407-PD-Q 41469407 24 Vdc Base Side 5-Y-41470-402-PD-Q 41470402 1 1 120 Vac Base Side 5-Y-41470-406-PD-Q 41470406 1 1 240 Vac Base Side 5-Y-41470-407-PD-Q 41470407 24 Vdc Panel Rear 5-Y-41625-402-PD-ER 41625402 1 120 Vac Panel Rear 5-Y-41625-406-PD-ER 41625406 1 240 Vac Panel Rear 5-Y-41625-407-PD-ER 41625407 1 1 Note 1 UL recognized. 1 1 1 1 1 1 V13-T1-76 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL recognized as indicated Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters/Totalizers 1.2 Technical Data and Specifications 1 General Specifications 1 Description Specification Number of digits Five Speed 1000 cpm Window Acrylic Shaft Stainless steel Frame Zinc alloy die cast Digit size 3/16 in high by 7/64 in wide (4.8 x 2.8 mm) 1 Series PD-Q 0.53 lb (0.24 kg) Series PD-ER 1.06 lb (0.48 kg) 1 1 1 1 Weight Dull Instrument black with red RESET button 1 Series PD-Q 9 watts 1 Series PD-ER Count coil 9 watts, reset coil 20 watts Finish Power consumption Switch rating 1 SPDT, 4 amperes at 250 Vac 1 Approximate Dimensions in Inches (mm) 1 PD-Q and PD-ER Series 1 Dimensions 1.56 1.18 (39.7) (30.1) Dia. 0.14 (3.6) 3.00 (76.2) 3.38 (85.7) 2.97 (75.4) 3.38 (85.7) 3.00 (72.6) 1.59 (40.5) 1.56 (39.7) 1.69 1.31 (42.8) (33.3) 1 2.72 (69.0) 2.69 (68.2) 1 Hole Dia. 0.13 (3.2) 1 3.06 (77.8) 1 1 1.69 (42.8) 4.38 (111.1) 4.00 (101.6) 1 2.69 (68.2) 1 1.63 2.00 (41.3) (50.8) 1.69 (42.8) 1 1 3.22 (81.8) 1 2.69 (68.2) 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-77 1.3 1 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters Contents Tachometers/Ratemeters Description 1 Page Count Controls/Preset Counters Product Selection Guide . . . . . . . . . . . . . . . . . . Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . Ambassador Series . . . . . . . . . . . . . . . . . . . . . 1 1 1 Learn Online 1 1 1 1 1 1 1 Product Overview 1 Ratemeters are used in a variety of applications where it is necessary to monitor the speed of a process. Conveyors, baking ovens, material flow and motor speed are typical uses for ratemeters. Models with alarm outputs can be used to detect high or low rates. Rate indicators are often included as a standard feature on totalizers and count controls. 1 Typical Application 1 1 1 1 1 1 1 1 1 1 1 Application Example 0 to 10 Vdc Feedback to Motor Drive Proximity Sensor Motor One of the most common ratemeter applications is a tachometer. A tachometer displays motor or shaft RPM. The inductive proximity sensor detects the key on the shaft and the meter calculates the rate at which the shaft is turning based on a user-defined scaling factor. Signals from encoders, mag pickups, Hall effect sensors, etc. may also be used as inputs. 1 1 1 1 1 V13-T1-78 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com High Alarm Output Low Alarm Output V13-T1-79 V13-T1-80 V13-T1-82 V13-T1-85 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 1.3 Product Selection Guide 1 1 Tachometers/Ratemeters Panel Cutout in Inches (mm) Characteristics E5-_24-E Compact device with bright, LED display Multiple functions available: count, time, rate, multifunction, double-function 0.870 x 1.772 (22 x 45) 1 Page V13-T1-44 1 1 24 Vdc Power E5-496-E Economical, multifunction display Large, LED characters 1.772 x 3.780 (45 x 96) 1 V13-T1-49 1 AC or DC power options 1 President Bright LED display with 14 mm characters Simple configuration with 14-button tactile keypad 2.667 x 5.433 (68 x 138) V13-T1-60 1 Many different versions fit almost any application E5-148-C Low cost, simple count control Various power options: battery, AC, DC 1 1.772 x 1.772 (45 x 45) 1 V13-T1-53 1 Easy-to-change preset values 1 Two-line display: input and preset values Courier Replaceable lithium battery Eight-digit, high-visibility LCD display 1.299 x 2.677 (33 x 68) 1 V13-T1-80 1 Optional backlighting 1 Various input options available Eclipse Six-digit, super bright LED display Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls Ambassador Six-digit, high-visibility, two-line LCD display User-configurable control inputs 1.772 x 3.780 (45 x 96) 1 V13-T1-82 1 2.667 x 2.667 (68 x 68) 1 V13-T1-85 1 Highly flexible control/display 1 1 Fusion Integrated controller combines operator interface, ladder logic and high-speed counting 2.667 x 5.433 (68 x 138) V13-T1-119 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-79 1.3 1 1 1 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters Courier Series Product Description Features Eaton's Courier Series is powered by a replaceable lithium battery. 1 1 1 Product Selection 1 Courier Series Standards and Certifications 1/Tau ratemeter Scaling capabilities Remote reset terminal 0.43 in (10.9 mm) display Front panel reset NEMA 4X CE marked LCD 1/Tau Ratemeter 1 1 Description Catalog Number 1 Battery 53300404 Extended temperature range, battery 53301404 Backlight, battery 53302404 1 1 1 1 Technical Data and Specifications General Specifications Description Specification Power 1 Internal battery 3V, Lithium 1 Life expectancy 5 years + Replacement part 35367-202 1 1 1 1 1 1 Backlight 10-30 Vdc at 30 mA max. 2 Backlight Reverse polarity protected Physical Operating temperature Model 53300-404 32 to 131F (0 to 55C) Model 53301-404 -4 to 158F (-20 to 70C) Model 53302-404 32 to 131F (0 to 55C) Storage temperature -4 to 158F (-20 to 70C) Operating humidity 60% RH (non-condensing) Weight 2.2 oz. (62g) net 1 Display size 0.43 in (10.9 mm) high 1 Front panel rating NEMA 4X when mounted with gasket provided Case material Cycolac X-17 1 Rate Indicator Type 1/Tau 1 Digits 4/5 (four calculated, five displayed with fixed 0 in LSD) 1 Scaler range 0.001 to 9999 Decimal point Five positions, programmable 1 Accuracy 0.2% Update time 0.7 seconds 1 Zero time 10 seconds 1 Notes 1 For units with rate and total, see Totalizers. 2 Derate operating temperature 1C/Volt above 17 Vdc. 1 V13-T1-80 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 1.3 General Specifications, continued Description 1 Specification 1 DC Common (Terminal 1) Rate Inputs Input B (terminal 2) low speed input designed for contact closures to DC common 1 Speed 0 to 20 Hz Min. low time 10 ms Min. high time 40 ms Input impedance 101k ohm 1 Low 0-0.4 Vdc 1 High 2.0-28 Vdc Max. high 28 Vdc 1 Voltage thresholds 1 1 Input A (terminal 3) high speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors 1 Speed 0 to 10 Hz 1 Min. low time 80 ms 1 Min. high time 20 ms 1 Input impedance 2k ohms above 5 Vdc 1 Low 0-1.2 Vdc High 2.0-28 Vdc 1 Max. high 28 Vdc 1 Voltage thresholds 1 Programmable Enable Input (Terminal 5) Operation Level sensitive (maintained) 1 100% 1 Count Accuracy Operated within specifications 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 Courier Series Ratemeter 1 1.25 (31.8) 1 1 1 1 2.95 (74.9) 2.67 (67.8) 1.57 (39.9) T/R Recommended Panel Cutout 1 1 1.30 (33.0) 1 RST 1 1 Note 1 Times are with a 0-5.0V swing. 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-81 1.3 1 1 1 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters Eclipse Series Product Description Features Eaton's Eclipse Series offers a high visibility LED and a variety of optional outputs. 1 1 1 1 1 1 1/8 DIN cutout NEMA 4X front panel Universal AC power supply (85-265 Vac) DC power modules (9-30 Vdc) Removable screw terminals Short depth: 3.6 in (91 mm) Front panel programming Standards and Certifications UL and cUL listed CE marked Product Selection Eclipse Series Five-Digit LED Ratemeter 57700470 Description Catalog Number 9-30 Vdc 57700470 9-30 Vdc, alarms 57700471 1 9-30 Vdc, analog out 57700472 9-30 Vdc, alarms, analog out 57700473 1 9-30 Vdc, RS-485 57700474 9-30 Vdc, alarms, RS-485 57700475 1 9-30 Vdc, alarms, analog out, RS-485 57700477 1 85-265 Vac 57701470 85-265 Vac, alarms 57701471 85-265 Vac, analog out 57701472 85-265 Vac, alarms, analog out 57701473 1 85-265 Vac, RS-485 57701474 85-265 Vac, alarms, RS-485 57701475 1 85-265 Vac, analog out, RS-485 57701476 85-265 Vac, alarms, analog out, RS-485 57701477 1 1 1 1 1 1 1 1 1 Technical Data and Specifications General Specifications Description Specification Input Power AC powered models (57701-4XX) Input power 85-265 Vac, 47-63 Hz, 20V A External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V) Isolation dielectric strength 2300 Vac DC powered models (57700-4XX) Input power 9-30 Vdc, 12 VA 1 External fuse 2.0A, 50 Vdc, time delay, (T2A, 50V) Reverse voltage protection Yes 1 Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs Human Interface 1 Display Five digits 1 Type 0.56 in high, seven segment, red LED Indicator One red LED program/calibration indicator Update time 0.1 to 99.9 seconds minimum 1 1 V13-T1-82 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 1.3 General Specifications, continued Description 1 Specification 1 Data Retention Memory type EEPROM, no batteries required Duration 100 years 1 Rate/process time Signal in 1 Sensor type Sink or source, DIP switch selectable Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground 1 3.5 to 28 Vdc 1 Signal Input Thresholds High Low 0 to 1.9 Vdc, for single ended signals 1 Magnetic pickup range 200 mV p-p to 65V rms into 34.9k ohms Frequency response 200 Hz max. or 10 kHz max. (5V signals), DIP switch selectable 1 Sensor type Sink only Input impedance 4.75k ohms to +5 Vdc 1 Thresholds High 3.5 to 28 Vdc 1 Program Enable Input Low Response 1 0 to 1.9 Vdc 25 ms max. (5V signal) 1 Accessory Power Output Voltage 12 Vdc 12% Current 75 mA max. Protection Short-circuit protected 1 1 Optional Outputs Relay board Number of relays 1 Two Contact type 1 set Form C per relay Contact rating 5A, 250 Vac or 30 Vdc Isolation dielectric strength 2300 Vac 1 4-20 mA (<750 ohms) and 0-10V (>2500 ohms) Analog retransmission Output signals 1 Accuracy 0.13% full scale and 100 PPM/C (and 0.07% full scale change over 4-20 mA load ranges) 1 Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to RS-485 and DC power inputs 1 1200, 2400, 4800, 9600, or 19,200, programmable 1 RS-485 serial communications Baud rate Parity Even, odd or no parity Address range 00 to 99 decimal Protocol Opto 22(R) compatible Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and DC power inputs 1 1 1 Environmental Operating environment Temperature Operating Storage Indoor use to 2000 meters 1 32 to 122F (0 to 50C) 1 -4 to 158F (-20 to 70C) Humidity 0 to 85% RH, non-condensing Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave EMC Immunity to EN 50082-2 (heavy industrial) 1 1 1 Emissions to EN 50081-2 (heavy industrial) Front panel NEMA 4X when mounted with gasket provided CE EMC immunity and emissions requirements Met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution degree 2 Overvoltage Category II Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 1 V13-T1-83 1.3 1 1 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters Dimensions Approximate Dimensions in Inches (mm) Eclipse Series Ratemeter 1 1 1 2.19 (55.6) 1.772 0.02 (45 0.6) PGM 1 4.04 (102.6) 1 3.622 0.031 (92.00 0.8) Panel Cutout 1 1 Max. Panel Thickness 0.190 (4.83) 1 1 3.63 (92.2) 1 3.31 (84.1) 1 0.27 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-84 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 1.3 Ambassador Series Product Description Features Eaton's most noise-immune ratemeter with an easy-toread two-line LCD. AC/DC powered, two-line LCD display Two-line, five-digit, high visibility, 0.3 in (7.5 mm) characters, backlit display One or two rate inputs Two rate alarms Dual rate unit ratio calculations--A/B, A-B or draw Standards and Certifications Programmable average and zero times Programmable decimal point 12 Vdc, 100 mA max. output power Removable screw terminals RS-485 communications NEMA 4 front panel UL and cUL listed CE marked 1 1 1 1 1 1 1 Product Selection 57150400 1 1 Ambassador Series Ratemeter Description Catalog Number 1 Single Input LCD rate indicator, 2 rate alarms, 10-15 Vdc 57150400 LCD rate indicator, 2 rate alarms, 115 Vac 57151400 LCD rate indicator, 2 rate alarms, 230 Vac 57152400 1 Rate/ratio/draw with alarms and analog out, 10-15 Vdc 57150405 Rate/ratio/draw with alarms and analog out, 115 Vac 57151405 1 Rate/ratio/draw with alarms and analog out, 230 Vac 57152405 1 Dual Input 1 1 Technical Data and Specifications 1 General Specifications 1 Specification 1 Model 57150-40X 10 to 15 Vdc, 300 mA maximum 1 Model 57151-40X 115 Vac (15%) 50-60 Hz, 7W Model 57152-40X 230 Vac (15%) 50-60 Hz, 7W 1 12 Vdc (25%), 100 mA maximum (includes all line and load variations) 1 Operating temperature 32 to 131F (0 to 55C) 1 Storage temperature -4 to158F (-20 to 70C) Operating humidity 85% relative, non-condensing NEMA 4 rating When mounted with gasket provided 1 Type 1/Tau Digits Five with overrange indication 1 Description Power Input DC Power Output (AC Models Only) Output Environment 1 Ratemeter Scaler range 0.00001 to 99999 Decimal point Five positions, programmable Average time 0.1 to 99.9 seconds, programmable Zero time 0.1 to 99.9 seconds, programmable Accuracy 0.015% of reading 1 1 1 1 Note 1 The accuracy of the ratio calculation is dependent upon the resolution of the displayed rates, which are calculated as rounded integers. The ratio calculation treats the displayed rate as integers and the result is displayed as a rounded integer. A and B scalers should be adjusted for maximum resolution. 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-85 1.3 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 1 General Specifications, continued 1 Maximum Rate Input Frequencies Maximum frequencies 1 Contact Input 1 Solid-State Input 1 1 All maximum frequencies listed are with a square wave input (50-50 duty cycle) Contact input 40 Hz Sinking sensor (all DIPs off) Sourcing sensor (push-pull output) High threshold (DIPs 1 and 2 on, 3 and 4 off) 0.5-4.5V, single input 40 kHz 0.5-4.5V, two inputs 30 kHz (each input) 1 0-15V, two inputs 22 kHz (each input) Low threshold (all DIPs on) 1 1 -1 to +1V, single input 27 kHz -2 to +2V, single input 43 kHz 1 1 0-5V, single input 50 kHz 0-5V, two inputs 30 kHz (each input) 1 1 7.3 kHz <-3 to >+3V, single input 60 kHz <-2 to >+2V, two inputs 30 kHz (each input) Rate Inputs Sink Impedance 4.6k ohms to +5 Vdc Voltage High 3.5 to 34.0, low 0.0 to 1.9 Vdc Source (high) 1 Impedance 2.3k ohms to common Voltage High 3.5 to 17.0 Vdc, low 0.0 to 1.9 Vdc 1 Source (low) 1 DC voltage High 0.63 to 17.0 Vdc, low -17.0 to -0.6 Vdc AC voltage 17 Vac (48V peak-peak) maximum 1 Impedance 2.3k ohms to common Control Inputs 1 Impedance 4.7k ohms to +5 Vdc Voltage High +3.7 to +24 Vdc, low 0.0 to 0.9 Vdc 1 Response Min, low 15 ms, min, high 15 ms Transistor Outputs (x2 for 5715X-401; x4 for 5715X-405) 1 Type 1 Max. voltage (OFF state) 30 Vdc Max. current (ON state) 200 mA at 1.3 Vdc NPN open collector with transient protection 1 Communication Type RS-485 1 Format One start bit, seven data bits (ASCII), one parity bit, one stop bit 1 Protocol Opto-22(R) compatible Speed 300, 1200, 2400, 4800, 9600, 19200 baud 1 Parity Odd, even, none (space transmitted, ignore received) 1 Range 0-10 Vdc 0.2% at 5 mA DAC resolution 12 bit Analog Output (Models 5715X-401 Only) 1 Connections 1 Type Dual depluggable screw terminal strips Conductor size 14-22 AWG (2.1-0.38 mm2), 600V, solid, stranded or fused (preferred) 1 1 V13-T1-86 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 1.3 Dimensions Approximate Dimensions in Inches (mm) 1 Ambassador Series Ratemeters 1 1 A 12345 R/M UNL CLR RUN PGM AKN EXIT ENT SEL 1 2.946 0.015 (74.83 0.38) 1 * 1 1 5.60 0.03 (142.24 0.76) 2.946 0.015 (74.83 0.38) 1 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 Panel Cutout Max. Panel Thickness 0.50 (12.7) 1 2.677 0.028 (68.00 0.70) 1 1 1 2.677 0.028 (68.00 0.70) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-87 1.4 1 Counters, Panel Meters, Tachometers and Timers Digital Panel Meters Contents Digital Panel Meters Description 1 Page Count Controls/Preset Counters E5-324-E Series. . . . . . . . . . . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 V13-T1-89 V13-T1-91 Learn Online 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Product Overview Digital Panel Meters are found anywhere a process variable needs to be indicated. Volts, current, pressure, volume, temperature and frequency are typical applications. The product's short depth makes it flexible and accommodating to panel builder needs. A variety of input and output options allows DPMs to be used virtually anywhere. Typical Application 1 1 1 1 Product Selection Guide Digital Panel Meters Characteristics E5-324-E Bright, easy-to-read LED in 1/32 DIN package Programmable scaling of inputs Page 0.870 x 1.772 (22 x 45) V13-T1-89 1.772 x 3.780 (45 x 96) V13-T1-91 Input for display-hold 24 Vdc power Eclipse Six-digit, super bright LED display Multiple models available: DC voltage, AC voltage, DC current, AC current, 5A AC current, 4-20 mA/0-10V process meter Various output options including relay, analog and RS-485 Monitor current draw from motor to identify potential failures Display pressure reading from transducer with highpressure alarm Display system voltage and detect under voltage or over voltage conditions 1 1 1 1 1 1 1 1 V13-T1-88 Panel Cutout in Inches (mm) Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 1.4 E5-324-E Series Product Description Features Eaton's most compact panel meter provides an easy-toread LED in a very small package. Galvanic isolation with protection against incorrect polarity Automatic MIN/MAX value detection Freely programmable characteristic curve end points Input Range-- Single current measuring input (0/4-20 mA) Single voltage measuring input (0/2-10V) Standards and Certifications Compact display for analog standard signals Display range -19.999 to 99.999 with zero blanking Modern industrial design Input for display-hold UL recognized CE marked 1 1 1 1 1 1 1 1 Product Selection E5-324-E0402 1 1 E5-324-E0402 Digital Panel Meter Description Catalog Number LED digital panel meter, 24 x 48 mm E5-324-E0402 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Supply voltage 10-30 Vdc, galvanically isolated with integrated protection against incorrect polarity Current consumption Max. 50 mA Display Five-digit display, red seven-segment LEDs; 0.31 in (8 mm) high Measuring rate Two measurements/second Data backup EEPROM Housing Housing for control panel 1.898 x 0.94 in (48 x 24 mm); acc. to DIN 43 700, RAL 7021, dark gray Ambient temperature 14 to 122 F (-10 to 50C) EMC According to EC EMC directive 89/36/EEC Interference emissions EN 61 000-6-4/EN 55011 Class B Interference resistance EN 61 000-6-2 Protection IP65 (front) Input current measurement 0-20 mA, 4-20 mA, voltage drop max. 1.5 Vdc Input voltage measurement 0-10V, 2-10V 1 1 1 1 1 1 1 1 1 Input resistance approx. 1M ohm Max. input signal level 30 Vdc 1 High 4-30 Vdc 1 Low 0-2 Vdc Control inputs Resolution 14 bits Error <0.1% for the whole measuring range at an ambient temperature of 68F (20C) Weight: Approx 1.76 oz (50g) Connection technique Screw terminal, pitch 0.2 in (5.08 mm), seven-poles 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-89 1.4 1 1 Digital Panel Meters Dimensions Approximate Dimensions in Inches (mm) E5-324-E Series 1 0.87 x 1.77 (22.0 x 45.0) 1.89 (48.0) 1 1 Counters, Panel Meters, Tachometers and Timers Panel Cut-Out: 0.87 + 0.01 x 1.77 + 0.02 (22.2 + 0.3 x 45 + 0.6) 1 0.16 (4.0) 2.09 (53.0) 1 0.98 + 0.02 (25 + 0.5) 0.04 (1.0) 1 Panel Cut-Out 0.16 (4.0) 1 1.97 + 0.02 (50 + 0.6) 2.20 (56.0) 1 1 1.97 + 0.02 (50 + 0.6) 0.98 x 1.97 (25 x 50) 1.10 (28.0) 1 1 0.26 (6.5) 2.32 (59.0) 1 1 Connections: 0.94 (24.0) 1 1 Max. 0.76 (19.3) 1.57 (40) 1.26 (32) 0.98 x 1.97 (25 x 50) 0.04 (1.0) 1 1 1.26 + 0.004 (32 + 0.1) 0.98 + 0.02 (25 + 0.5) 0.16 (4.0) M3 Panel Cut-Out 1 1 1 1 1 1 1 1 1 1 1 V13-T1-90 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 1.4 Eclipse Series Product Description Features Eaton's Eclipse Series panel meter features a highvisibility LED and is available with a variety of input and scaling options. Four full digits 1/8 DIN Size Red, LED display 0.56 in (14 mm) high characters Scalable display Flashing alarms Standards and Certifications Maximum/minimum data hold Optional analog, relay and RS-485 outputs NEMA 4X Depluggable terminal blocks UL and cUL listed CE marked 1 1 1 1 1 1 Eclipse Series Panel Meter 1 1 1 1 Catalog Number Selection 1 Eclipse Series 1 1 5770 X - 4 X X 1 Power Supply 0 = DC (9-30 Vdc) 1 = AC (85-265 Vac) 0 = DC volt 1 = AC volt TRMS 2 = DC amp 3 = AC amp TRMS Output Option 1 Input Option 4 = 5A AC TRMS 5 = Process (4-20 mA, 0-10V, 1-5V) 6 = Temperature (J, K, T, PT100 RTD) 1 0 = No option 1 = Dual relay 2 = Analog output (4-20 mA and 0-10V) 3 = Dual relay, analog output (4-20 mA and 0-10V) 4 = RS-485 communications 5 = Dual relay, RS-485 6 = Analog, RS-485 (4-20 mA and 0-10V) 7 = Dual relay, analog, RS-485 (4-20 mA and 0-10V) 1 1 1 1 Note 1 Output options 0, 2, 4 are not available for models -41X and -43X. 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-91 1.4 1 1 Counters, Panel Meters, Tachometers and Timers Digital Panel Meters Product Selection Eclipse Series Panel Meter Eclipse Digital Panel Meter Description Catalog Number 1 9-30 Vdc, DC volt 57700400 1 9-30 Vdc, DC volt, relay out 57700401 9-30 Vdc, DC volt, analog out 57700402 1 9-30 Vdc, DC volt, relay out, analog out 57700403 9-30 Vdc, DC volt, RS-485 57700404 1 9-30 Vdc, DC volt, RS-485, relay out 57700405 1 9-30 Vdc, AC volt, relay out, analog out 57700413 9-30 Vdc, DC amp 57700420 1 9-30 Vdc, DC amp, relay out 57700421 9-30 Vdc, DC amp, analog out 57700422 1 9-30 Vdc, AC amp, relay out 57700431 9-30 Vdc, 5A AC 57700440 1 9-30 Vdc, 5A AC, relay out 57700441 1 9-30 Vdc, 5A AC, analog out 57700442 85-265 Vac, DC volt 57701400 1 85-265 Vac, DC volt, relay out 57701401 85-265 Vac, DC volt, analog out 57701402 1 85-265 Vac, DC volt, analog out, relay out 57701403 85-265 Vac, DC volt, RS-485 57701404 1 85-265 Vac, DC volt, RS-485, relay out 57701405 1 85-265 Vac, AC volt 57701410 85-265 Vac, AC volt, relay out 57701411 1 85-265 Vac, AC volt, analog out 57701412 85-265 Vac, AC volt, relay out, analog out 57701413 1 85-265 Vac, AC volt, RS-485, analog out, relay out 57701417 1 85-265 Vac, DC amp 57701420 85-265 Vac, DC amp, relay out 57701421 1 85-265 Vac, DC amp, analog out 57701422 85-265 Vac, DC amp, relay out, analog out 57701423 1 85-265 Vac, DC amp, RS-485, analog out, relay out 57701427 85-265 Vac, AC amp 57701430 1 85-265 Vac, AC amp, relay out 57701431 1 85-265 Vac, AC amp, analog out 57701432 85-265 Vac, AC amp, analog out, relay out 57701433 1 85-265 Vac, AC amp, RS-485 57701434 85-265 Vac, 5A AC 57701440 1 85-265 Vac, 5A AC, relay out 57701441 85-265 Vac, 5A AC, analog out 57701442 85-265 Vac, 5A AC, analog out, relay out 57701443 85-265 Vac, 5A AC, RS-485, analog out 57701446 1 1 1 1 1 1 V13-T1-92 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 1.4 Eclipse Process Description Catalog Number 9-30 Vdc 57700450 9-30 Vdc, relay out 57700451 9-30 Vdc, analog out 57700452 9-30 Vdc, relay out, analog out 57700453 9-30 Vdc, RS-485 57700454 85-265 Vac 57701450 85-265 Vac, relay out 57701451 85-265 Vac, analog out 57701452 85-265 Vac, analog out, relay out 57701453 85-265 Vac, RS-485 57701454 85-265 Vac, RS-485, relay out 57701455 85-265 Vac, RS-485, analog out 57701456 85-265 Vac, relay out, analog out, RS-485 57701457 1 1 1 1 1 1 1 1 1 1 Eclipse Temperature Description Catalog Number 9-30 Vdc 57700460 9-30 Vdc, relay out 57700461 9-30 Vdc, relay out, analog out 57700463 85-265 Vac 57701460 85-265 Vac, relay out 57701461 85-265 Vac, analog out 57701462 85-265 Vac, relay out, analog out 57701463 85-265 Vac, RS-485 57701464 85-265 Vac, RS-485, analog out, relay out 57701467 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-93 1.4 Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Input Power 1 Input power 85-265 Vac, 47-63 Hz, 20 VA External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V) Isolation dielectric strength 2300 Vac 1 1 AC powered models (57751-4XX) DC powered models (57750-4XX) Input power 9-30 Vdc, 12 VA 1 External fuse 2.0A, 50 Vdc, time delay (T2A, 50V) 1 Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs 1 Human Interface Display 4 full digits 1 Type 0.56 in (14 mm) high, seven segment, red LED Update time 0.4 seconds 1 Alarm Flashing display 1 Indicator One red LED program/calibration indicator with max./min. capture and hold Data Retention 1 Memory type EEPROM, no batteries required Duration 100 years 1 Signal Input DC voltage models (5770X-40X) 1 Range 199.9m Vdc, 1.999 Vdc, 19.99 Vdc, 199.9 Vdc, DIP switch selectable 1 Impedance 1M ohm Overrange 750 Vdc/530 Vac except 220 Vdc/Vac on 199.9 mV range Accuracy 0.1% of reading, 0.03% FS, 0.5 digit, and 80 PPM/C 1 AC voltage models (5770X-41X) 1 Range 199.9 m Vac, 1.999 Vac, 19.99 Vac, 199.9 Vac, DIP switch selectable, all ranges true rms Frequency 40 to 1000 Hz 1 Impedance 1M ohm (capacity coupled) Overrange 750 Vdc/530 Vac except 220 Vdc/Vac on 199.9 mV range Accuracy 0.5% of reading, 0.13% FS, 0.5 digit, 180 PPM/C for crest factor = 1; plus 0.7% for crest factor = 1 to 3; and 2.5% for crest factor = 5 1 1 1 1 1 DC current models (5770X-42X) Range 199.9 A DC, 1.999 mA DC, 19.99 mA DC, 199.9 mA DC, DIP switch selectable Impedance 199.9 mV/selected range Overrange 30 mA (199.9 A range), 100 mA (1.999 mA range), 300 mA (19.99 mA range), 1A (199.9 mA range) Accuracy 0.1% of reading, 0.03% FS, 0.5 digit, and 120 PPM/C AC current models (5770X-43X) Range 199.9 A AC, 1.999 mA AC, 19.99 mA AC, 199.9 mA AC, DIP switch selectable, all ranges true rms Frequency 40 to 1000 Hz Impedance 199.9 mV/selected range (shunt output capacitive coupled) 1 Overrange 30 mA (1199.9 A range), 100 mA (1.999 mA range), 300 mA (19.99 mA range), 1A (199.9 mA range) 1 Accuracy 0.5% of reading, 0.13% FS, 0.5 digit, and 200 PPM/C for crest factor = 1; plus 0.7% for crest factor = 1 to 3; and 2.5% for crest factor = 5 1 1 1 1 V13-T1-94 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 1.4 General Specifications, continued Description 1 Specification 1 Signal Input, continued 5A AC models (5770X-44X) Range 5A AC, true rms Frequency 40 to 1000 Hz Impedance 0.02 ohm (shunt output capacitive coupled) Overrange 10A maximum Accuracy 0.4% of reading, 0.13% FS, 0.5 digit, and 200 PPM/C for crest factor = 1; plus 0.7% for crest factor = 1 to 3; and 2.5% for crest factor = 5 1 1 1 1 Process models (5770X-45X) Range 4-20 mA DC, 0-10 Vdc, 1-5 Vdc; separate input terminals for voltage and current signals Impedance 100 ohms (current input) and 1.27M ohms (voltage input) Overrange 50 mA maximum (current input) and 100V maximum (voltage input) Power output 24 Vdc 10%, 90 mA max, short-circuit protected Accuracy 0.1% of reading, 0.03% FS, 0.5 digit, and 80 PPM/C 1 1 1 Optional Outputs 1 Relay board Dual relay 1 set of Form C contacts each Contact rating 5A, 250 Vac or 30 Vdc Isolation dielectric strength 2300 Vac 1 Output signals 4-20 mA (<750 ohms) and 0-10V (>2500 ohms) Accuracy 0.13% FS, 100 PPM/C, 0.07% FS change with 4-20 mA load, 0.3% FS for 4-20 mA output, only after exposure to 85% relative humidity 1 Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power input; 500 Vac to RS-485 and DC power inputs 1 Analog retransmission 1 1 RS-485 serial communication Baud rate 1200, 2400, 4800, 9600 or 19,200, programmable Parity Even, odd or no parity Address range 00 to 99 decimal Protocol Opto 22(R) compatible Isolation dielectric strength 2300 Vac to signal inputs, relays, and AC power input; 500 Vac to analog outputs and DC power inputs 1 1 1 1 Environmental Operating environment Indoor use to 2000 meters 1 Operating 32 to 122F (0 to 50C) Storage -4 to 158F (-20 to 70C) 1 Temperature Humidity 0 to 85% RH, non-condensing Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave EMC/EMI Per EN 61326-1 industrial Front panel NEMA 4X when mounted with gasket provided Agency approval CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and signal input lines. The shields were connected to earth ground at the Eclipse end of the shields. 1 1 1 1 1 Conducted emissions requirements were met assuming that the AC signal input would not be connected directly to the AC mains. 1 The measurement error during RF immunity testing was less than 5% of full scale. In addition, models with an AC signal input had measurement error of less than +25% of full scale during RF immunity testing of the RS-485 at frequencies below 1 MHz. Pollution degree 2 1 Overvoltage Category II 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-95 1.4 1 1 Counters, Panel Meters, Tachometers and Timers Digital Panel Meters Dimensions Approximate Dimensions in Inches (mm) Eclipse Series 1 1 1 2.19 (55.6) 1.772 0.02 (45 0.6) PGM 1 4.04 (102.6) 1 3.622 0.031 (92.0 0.8) Panel Cutout 1 1 Max. Panel Thickness 0.19 (4.8) 1 1 3.63 (92.2) 1 3.31 (84.1) 1 0.27 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-96 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 Contents Timers/Hour Meters Description Timers/Hour Meters Product Selection Guide . . . . . . . . . . . . . . . . . . Electronic Timers/Hour Meters . . . . . . . . . . . . . Electromechanical Timers/Hour Meters . . . . . . Page V13-T1-98 V13-T1-99 V13-T1-105 Learn Online 1 1 1 1 1 1 1 1 1 1 Product Overview Typical Application Timers are used in applications where time itself is the main focus. These include simple knowledge of how long a machine has been running to determine machine maintenance, for example, (elapsed time) to knowing when to change an elevator cable (cable life and safety). Timers generally have the ability to stop and then to continue on from the point at which they stopped. Timer relays are used in applications where an output is required to make something happen at a predetermined point in time (to stop or start the process). 1 1 Elapsed time indication for interval maintenance of construction and agricultural equipment Usage metering for determining charges on rental equipment Controlled process timing for adhesive application/ curing equipment 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-97 1.5 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters Product Selection Guide 1 Timers/Hour Meters 1 Characteristics E5-_24-E Compact device with bright, LED display 1 Multiple functions available: count, time, rate, multifunction, doublefunction 1 24 Vdc Power 1 E5-496-E Economical, multifunction display Large, LED characters 1 Panel Cutout in Inches (mm) Page 0.870 x 1.772 (22 x 45) V13-T1-44 1.772 x 3.622 (45 x 92) V13-T1-49 0.870 x 1.772 (22 x 45) V13-T1-100 Various V13-T1-105 1.988 (50.5) dia. or DIN rail V13-T1-111 AC or DC power options 1 1 E5-224-C Non-replaceable battery (minimum eight-year life) Compact, low cost and high efficiency 1 Eight-digit LCD timer 1 Various timing modes (Hr/Min/Sec) 1 Manual or electrical reset Hour Meters Compact, low-cost LCD and electromechanical elapsed time meters Various power options for almost any power supply 1 1 1 Hour Meter/Counter Combination counter consists of time meter and adding counter in one 1 Without reset 1 Magnified figures 1 Data retention if power is lost 1 UL Approved High shock resistance Protection IP52 (front) Long service life 1 1 1 1 1 1 1 1 1 1 1 V13-T1-98 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 Contents Electronic Timers/Hour Meters Description Electronic Timers/Hour Meters 1/32 DIN LCD--Timers . . . . . . . . . . . . . . . . . . . E42DI24/E42DIR Series . . . . . . . . . . . . . . . . . . Electromechanical Timers/Hour Meters . . . . . . . . Page V13-T1-100 V13-T1-103 V13-T1-105 1 1 1 1 1 1 1 1 1 1 1 Electronic Timers/Hour Meters Product Overview Features Eaton's electronic hour meters are a simple and effective way to monitor equipment on time. Reset or non-reset Variety of power options LCD displays 1 Standards and Certifications UL recognized CE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-99 1.5 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1/32 DIN LCD--Timers Product Description Features Simple battery-powered timers provide an easy-toread LCD and a variety of timing display options. 1 1 1 Low price and high efficiency Large eight-digit LCD display, height of the figures 0.31 in (8 mm) Different time ranges from 0.1 second to 100,000 hours 0.1 second synchronization makes it suitable for very short activation times Standards and Certifications High voltage input for 10-260 Vac/Vdc voltage pulses IP65 Screw terminals, RM 5 mm Lifetime of the battery approximately eight years Locking of the reset key Operating temperature 14 to 140F (-10 to 60C) 1 1 Product Selection 1 E5-224-C04_ 1/32 DIN LCD Timers 1 Description 1 Hours/minutes, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0440 Hours/minutes, 10-260V input, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0448 Minutes/seconds, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0450 Minutes/seconds, 10-260V input 0.94 x 1.89 in (24 x 48 mm) E5-224-C0458 Eight-Digit LCD Timer, Battery Power 1 1 1 1 Catalog Number Technical Data and Specifications General Specifications 1 Description Specification Power supply Non-replaceable lithium battery (lifetime approximately eight years at 68F (20C) 1 Display LCD, eight-digits 1 Figure size 0.31 in (8 mm) high Counting direction Adding 1 Display range 1 Display 1 1 1 1 1 Time range Time range 99999h 59m (134) 99999.99h (134) Display Time range 9999h 59m 59s (135) Display Time range 9999999.9s (135) Display Reset Manual and electrical 1 1 1 1 V13-T1-100 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL recognized CE marked Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 General Specifications, continued Description 1 Specification 1 Timer inputs, DC versions (max. 30 Vdc) Timer input NPN or PNP depending on the type 1 Switching level NPN low 0-0.7V NPN high 3-30 Vdc PNP low 0-0.7V PNP high 4-30 Vdc 1 NPN For low signal at the timer input 1 PNP For high signal at the timer input 1 Timer input Optocoupler input max. 30 Hz Min. pulse time 16 ms 1 1 Counting start Timer inputs, high voltage version (10-260 Vdc/Vac) 1 Switching level Low High Counting start 0-2 Vdc/Vac 1 10-260 Vdc/Vac For high signal at the timer input 1 Time range change (mode) 1 Contact input--open collector (switching at 0V) NPN low 0-0.7V NPN high 3-5 Vdc Time range 1 Depending on the circuit 1 Reset Input (only DC and high voltage) Minimum pulse time 1 DC 50 ms High voltage 10 ms 1 NPN low 0-0.7V NPN high 3-30 Vdc 1 Contact input (DC) High voltage input 1 10-260 Vdc/Vac Reset locking input (for DC and AC), electrical reset key locking 1 Input not active Reset key locked Contact input Open collector NPN (switching at 0V) 1 NPN low 0-0.7V 1 NPN high 3-5 Vdc Switching level Interference emissions 1 EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions) Housing Dark gray RAL 7021 Operating temperature 14 to 131F (-10 to 55C) Ambient temperature 14 to 140F (-10 to 60C) Storage temperature -4 to 158F (-20 to 70C) Protection IP65 (from front) Weight Approx. 1.76 oz (50g) 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-101 1.5 1 1 1 Timers/Hour Meters Dimensions Approximate Dimensions in Inches (mm) 1/32 DIN LCD Timers 1 1 Counters, Panel Meters, Tachometers and Timers MAX. 1.89 (19.3) 1.89 (48) 0.87 x 1.77 (22 x 45) 0.94 (24) 1 0.11 (2.8) 1.88 (47.7) 1 1.77 + 0.024 (45 + 0.6) 1 1 1 0.12 (3) 1.77 + 0.012 (22.2 +0.3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-102 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 E42DI24/E42DIR Series Product Description Features Simple LCD hour meters with flexible input voltages Solid-state hour meters Record and display up to 99,999.9 hours, rollover and continue timing EEPROM memory can retain data for 25+ years Standards and Certifications Time accumulation indicated by flashing hourglass icon Memory will arm only when power has been applied for 5 seconds UL recognized CE compliant 1 1 1 1 E42DI24/E42DIR Series Elapsed Time Meters Description E42DI24_ 1 1 Product Selection E42DIR_ 1 1 Catalog Number Round LCD Elapsed hour meter, 48-150 Vdc/100-230 Vac E42DIR48230 Elapsed hour meter with reset, 48-150 Vdc/100-230 Vac E42DIR48230R Elapsed hour meter, 12-48 Vdc/20-60 Vac E42DIR1260 1 1 1 Rectangular LCD Elapsed hour meter, 48-150 Vdc/100-230 Vac E42DI2448230 Elapsed hour meter, with reset, 48-150 Vdc/100-230 Vac E42DI2448230R Elapsed hour meter, 12-48 Vdc/20-60 Vac E42DI241260 1 1 1 Technical Data and Specifications 1 General Specifications Description Specification Function Solid-state hour meter 1 Power supply E42DIXX1260X 12-48 Vdc 25%/20-60 Vac 25% 1 E42DIXX48230X 1 48-150 Vdc +23%-25%/100-230 Vac +17%-25% Frequency range 48-440 Hz Display Six-digit LCD, 0.20 in (5 mm) Accuracy 0.1% Recording/display capacity 99,999.9 hours Resolution 0.1 hour (6 minutes) Current consumption max. at nominal voltage E42DIXX1260X 0.8 mA at 12 Vdc 1 1 1 1 5.0 mA at 48 Vdc 0.5 mA at 20 Vac 1 2.5 mA at 60 Vac E42DIXX48230X 0.8 mA at 48 Vdc 1 2.5 mA at 150 Vdc 2.0 mA at 230 Vac 1 70k ohms 1 0.9 mA at 100 Vac Input impedance minimum (pins 3 and 4) E42DIXX1260X E42DIXX48230X 1 480k ohms Operating temperature -40 to 185F (-40 to 85C) Storage temperature -58 to 194F (-50 to 90C) 1 1.94 oz (55g) 1 Weight E42DIRXXXXXX E42DI24XXXXXX 0.78 oz (22g) Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 V13-T1-103 1.5 1 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters Dimensions Approximate Dimensions in Inches (mm) E42DI24/E42DIR Series 1 U Clamp for 0.03 - 0.25 (7.6 - 6.4) Panel Thickness 1 Washer Thumbnut 0.16 (4.0) Black Bezel 1 QUARTZ HOURS 1 1 -- 10 Terminal 0.25 (6.4) Max. 1 1 0.35 (8.9) Max. Dia. 2.30 (58.4) Max. 1 1 1 1 1 Dia. 2.06 (52.3) Max. 0.52 (13.2) Max. 1.40 (35.6) 0.06 (1.5) 1.13 (28.6) Max. 1.13 (28.7) Terminal 0.25 (6.4) +0.01 HOURS 0.89 (22.6) 1/10 1.75 (44.5) 2.00 (53.1) 1 1 1.22 (31.1) 0.95 -0.00 +0.25 (24.1 -0.00) 0.93 (23.6) 0.18 (4.7) +0.01 0.71 (18) 1.45 -0.00 +0.25 (36.8 -0.00) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-104 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 Contents Electromechanical Timers/Hour Meters Description Electronic Timers/Hour Meters . . . . . . . . . . . . . . . Electromechanical Timers/Hour Meters 1/16 DIN Hour Meters . . . . . . . . . . . . . . . . . . . 71.1 Round Hour Meters . . . . . . . . . . . . . . . . . Hour Meter/Counter . . . . . . . . . . . . . . . . . . . . . Page V13-T1-99 V13-T1-106 V13-T1-109 V13-T1-111 1 1 1 1 1 1 1 1 1 1 1 Electromechanical Timers/Hour Meters Product Overview Features Eaton's electromechanical hour meters are available in a variety of configurations and provide a cost-effective way to monitor equipment on time. Non-resettable Always readable display 1 Standards and Certifications UL recognized CE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-105 1.5 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1/16 DIN Hour Meters Product Description Typical Application Eaton's most cost-effective elapsed time meter. Features IP65 protection against water intrusion. 1 1 1 1 1 General elapsed time Service interval for measurement systems-- Respiratory ventilators Oxygen machines Dialysis machines Small appliances UV lamps Display panels in cars Features High shock resistance Without reset Small dimension Magnified figures Protection IP65 Data retention if power is lost Long service life Optional mounting position Product Selection 7-T-65-4848PM-40_ 1 1/16 DIN Hour Meters Description Catalog Number 10-30 Vdc, 1.89 x 1.89 in (48 x 48 mm) 8-T-65-4848PM-402 100-130 Vac, 1.89 x 1.89 in (48 x 48 mm) 7-T-65-4848PM-406 1 1 1 T4848DINADAPT 1 DIN Rail Adapter Description Catalog Number DIN rail adapter for DIN electromechanical hour meter T4848DINADAPT 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-106 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Standards and Certifications UL recognized Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 Technical Data and Specifications 1 General Specifications Description Specification 1 Electrical connection Clamp terminal for cable diameter up to 14 AWG (2.5 mm2), tightening torque max. 0.59 lb-ft (0.8 Nm) 1 10-30 Vdc Approx. 500 mW 1 100-130 Vdc Approx. 750 mW Power consumption 1 Rated voltages 100-130 Vac, 50 or 60 Hz On time 100% 1 Seven at AC 99999.99 Eight at DC 999999.99 1 1 10-30 Vdc Display 1 Accuracy AC DC Supply frequency + 30 ms 1 <0.003% (24h) Count mode Adding Figure size 0.16 in (4 mm) high Color of figures White and red-on-black Ambient temperature 5 to 122F (-15 to 50C) Mounting position Any Protection IP65 1 1 1 1 Housing Plastic Weight 1.7 oz (48g) 1 AC Fast rotating wheel with red dashes DC 1/100h display turns continuously by 1-digit in 36 seconds 1 Operating indicator of the running time meter Test voltage 2000 Vac, 50 Hz for AC counters Options Further voltages on request Color of housing Gray 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-107 1.5 1 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters Dimensions Approximate Dimensions in Inches (mm) 1/16 DIN Hour Meters 1 1 Dia. 1.97 (50) 1 1 1 1.89 (48) SQ. 0.35 (9) Max. 1 1.10 (28) 1 1 1 1 0.28 (7) Screw Terminal SQ. Panel Cut-Out DIN Rail Adapter 1.91 (48.5) 1 1 1.77+0.02 (45+0.6) 1.77 (45) SQ. 2.42 (61.5) 1 0.75 (19) 1.62 (41.1) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-108 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 71.1 Round Hour Meters Product Description Typical Application Eaton's 6-T-3H hour meters are heavy-duty elapsed time meters with NEMA 4X protection. General elapsed time Utility vehicles Construction machines Generators Fork-lift trucks Car washes Outside areas Features Six-digit hour meter for round panel cut-out Low cost High shock resistance Low power consumption Small dimension Magnified figures Waterproof NEMA Type 4X rating Data retention if power is lost Available in 50 pc. bulk package Standards and Certifications UL recognized 1 1 1 1 1 1 1 1 1 Product Selection 6-T-3H-508RPM-40_ 1 71.1 Round Hour Meters Description Catalog Number 115 Vac, 2.80 in (71.1 mm) round 6-T-3H-508RPM-406 10-80 Vdc, 2.80 in (71.1 mm) round 6-T-3H-508RPM-402 1 1 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Electrical connection Flat pins 0.8 x 6.3 Power consumption AC 1 Max. 0.4 VA 1 12 Vdc Max. 0.08W 48 Vdc Max. 0.7W Rated voltages 115 Vac 10%, 50/60 Hz, 10-80 Vdc On time 100% Display Six-digits, 99999.9h Count mode Adding Figure size 0.14 in (3.5 mm) high Reset None Ambient temperature -22 to 149F (-30 to 65C) Mounting position Any Protection IP65 Housing Plastic Error <0.02% over the full range 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-109 1.5 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters Dimensions Approximate Dimensions in Inches (mm) 71.1 Round Hour Meter Dia. 2.54 (64.5) Dia. 2.44 (62) Dia. 0.15 (3.8) 1 120 0.03 x 0.25 (0.8 x 6.3) Dia. 0.13 (3.3) 1 Dia. 2 (50.8) 1.68 (42.7) 1 Dia. 2 (50.8) 1 Dia. 2.80 (71.1) 1 0.47 (12) 1.26 (32) 0.21 (5.3) Panel Cut-Out 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-110 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters 1.5 Hour Meter/Counter Product Description Typical Application Eaton's CEC series combination meters provide an event counter and elapsed time meter is one compact unit. General counting Pump control panels Service interval for measurement systems (respiratory ventilators, oxygen machines, dialysis machines) Small appliances UV lamps Display panels in cars Features Combination counter consists of time meter and adding counter in one Without reset High shock resistance Magnified figures Protection IP52 (front) Data retention if power is lost Long service life Standards and Certifications cRU(R)us certified CE marked 1 1 1 1 1 1 1 Product Selection CEC-...-406 1 1 Hour Meter/Counters Description Catalog Number Combination hour meter/counter, 55 mm square front panel mount, 100-130 Vac, 60 Hz CEC-55PM-406 Combination hour meter/counter, 48 mm DIN rail mount, 100-130 Vac, 60 Hz CEC-48DR-406 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Electrical connection Flat pin 0.8 x 6.3 mm with screw terminal, tightening torque max. 0.8 Nm 1 Power consumption 100-130 Vac 60 Hz, approx. 1.43 VA 1 Count mode Adding Figure size 0.16 x 0.07 in (4 x 1.7 mm) 1 Color of figures Hour White on black 1 Decimal Running time meter operating indicator 1 Red on black Fast rotating wheel with red dashes; 99999.99 hour Accuracy AC Supply frequency 30 ms Reset None Ambient temperature 5 to 122F (-15 to 50C) Mounting position Any Color of housing Black 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-111 1.5 1 1 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters Dimensions Approximate Dimensions in Inches (mm) DIN Rail Mount 1 0.197 (5.0) 1 1 1 1 1 1 2.106 (53.5) h 2.421 (61.5) SQ 1.91 (48.5) 0.748 (19.0) 0.047 (1.2) Front Panel Mount 1 0.256 (6.5) Max. 1 1 h 1 1 1 1 0.047 (1.2) SQ 2.166 (55.0) 1.122 (28.5) 0.374 (9.5) Dia. 1.988 (50.5) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-112 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls 1.6 Contents Flow Totalizers, Transmitters and Controls Page 1 V13-T1-113 V13-T1-114 1 Description Flow Totalizers, Transmitters and Controls Product Selection Guide . . . . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 Learn Online 1 1 1 1 1 1 1 Product Overview Flow products are used in a variety of applications where liquid gas flow needs to be monitored or controlled. Eaton offers models for flow total, flow rate and flow batch control. Several optional outputs allow great flexibility to meet most application needs. 1 1 Flow Sensor 1 1 Typical Application 1 53300-405 Totalizer/Ratemeter In many processes, it is desirable to know both the total quantity of product being produced and the rate at which the product is being produced. In the illustration at right, the output of a turbine flow sensor is connected to a totalizer/ratemeter. The flow sensor produces a known number of pulses per gallon (or other unit of measure). The instrument scales these pulses into the desired units of flow volume (gallons, liters, barrels, etc.), and flow rate (gallons/minute, barrels/ hour, etc.). 1 Application Example 1 1 1 1 Liquid 1 1 Product Selection Guide 1 Totalizers 1 Eclipse Characteristics Typical Applications Six-digit, super bright LED display Length measurement and control Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls Flow monitoring and control Panel Cutout in Inches (mm) 1.772 x 3.780 (45 x 96) Page V13-T1-114 1 1 1 Process monitoring and display Voltage and current monitoring and display 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-113 1.6 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls Eclipse Series Product Description Features Eaton's Eclipse series flow totalizer and controller can accept signals from analog flow meters and display flow rates and volumes on a highvisibility LED. 1 1 1 1 Standards and Certifications Six- or 10-digit display 1/8 DIN size Red, LED display 0.56 in (14 mm) high characters Scalable display Analog or pulse input versions Accessory power output 15-point linearization available Dual valve pre-warn available Optional analog, relay and RS-485 outputs NEMA 4X Depluggable terminal blocks Eclipse Series Flow Totalizer and Control 1 1 1 1 1 Catalog Number Selection 1 Eclipse Flow Model 5775 X - 4 X X 1 1 1 Power Supply 0 = DC (9-30 Vdc) 1 = AC (85-265 Vac) 1 Input Option 0 = Pulse input totalizer/ratemeter 1 = Pulse input batch control 2 = Analog input totalizer/ratemeter 3 = Analog input batch control 1 1 1 1 0 1 2 3 4 5 6 7 A B C D Output Option 1 = No option = Dual relays (standard or batch) = Analog output (4-20 mA and 0-10V) = Dual relays and analog output = RS-485 communications = Dual relay and RS-485 = Analog output and RS-485 = Dual relays, analog output and RS-485 = One relay, one transistor = One relay, one transistor, analog output = One relay, one transistor, RS-485 = One relay, one transistor, analog output and RS-485 Note 1 Output options 0, 2, 4 are not available for models -41X and -43X. 1 1 1 1 1 1 1 1 V13-T1-114 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL and cUL listed CE marked Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls 1.6 Product Selection Eclipse Series Totalizer Display Preset Counter 1 Eclipse Series Totalizer Display Preset Counters Description Catalog Number Flow total rate, DC, pulse input 57750400 Flow total rate, DC, pulse input, dual relay out 57750401 Flow total rate, DC, pulse input, analog out 57750402 Flow total rate, DC, pulse input, dual relay out, analog out 57750403 Flow total rate, DC, pulse input RS-485 57750404 Flow batcher, DC, pulse input, dual relay out 57750411 Flow batcher, DC, pulse input, dual relay out, RS-485 57750415 Flow total/rate, DC, analog input 57750420 Flow total/rate, DC, analog input, dual relay out 57750421 Flow total/rate, DC, analog input, analog out 57750422 Flow total/rate, AC, pulse input 57751400 Flow total/rate, AC, pulse input, dual relay out 57751401 Flow total/rate, AC, pulse input, analog out 57751402 Flow total/rate, AC, pulse input, dual relay out, analog out 57751403 Flow total/rate, AC, pulse input, analog out 57751404 Flow batcher, AC, pulse input, dual relay out 57751411 Flow batcher, AC, pulse input, dual relay out, analog out 57751413 Flow batcher, AC, pulse input, dual relay out, RS-485 57751415 Flow total/rate, AC, analog input 57751420 Flow total/rate, AC, analog input, dual relay out 57751421 Flow total/rate, AC, analog input, analog out 57751422 Flow total/rate, AC, analog input, dual relay out, analog out 57751423 Flow total/rate, AC, analog input, analog out, RS-485 57751426 Flow batcher, AC, analog input, dual relay out 57751431 Flow total/rate, AC, pulse input, relay/transistor out 5775140A Flow total/rate, AC, pulse input, relay/transistor out, analog out, RS-485 5775140D Flow total/rate, AC, analog input, relay/transistor out 5775142A Flow total/rate, AC, analog input, relay/transistor out, analog 5775142D Flow batcher, AC, analog input, relay/transistor out, analog 5775143D 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-115 1.6 Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Input Power 1 Input power 85-265 Vac, 47-63 Hz, 20 VA External fuse 0.2A, 250 Vac, time delay (T200mA, 250V) Isolation dielectric strength 2300 Vac 1 1 AC powered models (57751-4XX) DC powered models (57750-4XX) Input power 9-30 Vdc, 12 VA 1 External fuse 2.0A, 50 Vdc, time delay (T2A, 50V) 1 Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs 1 Human Interface Display Six digits 1 Type 0.56 in high, seven segment, red LED Data Retention 1 Memory type EEPROM, no batteries required 1 Duration 100 years Count Signal Input/Count Inhibit Signal Input 1 Sensor type Sink or source, DIP switch selectable Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground 1 Thresholds 1 1 High 3.5 to 28 Vdc Low 0 to 1.9 Vdc, for single ended signals Magnetic pickup range 50 mV p-p to 65V rms into 34.9k ohms Slow response 50 Hz max. (DIP switch 2 and/or 5 ON) 1 Flat response 10 kHz 1 Types Flow Signal Input (Analog Input Models) 4-20 mA and 0-10 Vdc Input impedance 100 ohms (current input), 1.27M ohms (voltage input) 1 Overrange 50 mA max. (current input), 100V max. (voltage input) 1 Accuracy 0.1% of reading, 1 digit, and 80 PPM/C Control Inputs 1 Sensor type Sink only Input impedance 4.75k ohms to +5 Vdc 1 Thresholds 1 1 High 3.5 to 28 Vdc Low 0 to 1.0 Vdc Response 25 ms maximum (5V signal) Accessory Power Output (Pulse Input Models) 1 Voltage 12 Vdc +10%/-13% Current 75 mA max. 1 Protection Short-circuit protected Accessory Power Output (Analog Input Models) 1 Voltage 24 Vdc 10% 1 Current 90 mA max. Protection Short-circuit protected 1 1 V13-T1-116 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls 1.6 General Specifications, continued Description 1 Specification 1 Relay/Transistor Outputs (Standard on Batch Controls, Optional on Totalizers) Number Two relays or one relay and one transistor Relay contact type One set Form C per relay Relay contact rating 5A, 250 Vac or 30 Vdc Transistor type NPN, opto isolated OFF state block 30 Vdc max., 0.1 mA max. leakage current ON state conduct 50 mA max., 1.2 Vdc max. C-E drop Max. switching frequency 4 kHz (50-50 duty cycle) Isolation dielectric strength 2300 Vac 1 1 1 1 1 Optional Outputs Analog retransmission Output signals 4-20 mA (<750 ohms) and 0-10V (>2500 ohms) Accuracy 0.13% full scale and 100 PPM/C (and 0.07% full scale change over 4-20 mA load ranges Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and DC power inputs 1 1 1 RS-485 serial communications Baud rate 1200, 2400, 4800, 9600, or 19,200, programmable Parity Even, odd or no parity Address range 00 to 99 decimal (00 indicates off line) Protocol Opto 22(R) compatible Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and DC power inputs 1 1 1 1 Environmental Operating environment Indoor use to 2000 meters 1 Operating 32 to 122F (0 to 50C) Storage -4 to 158F (20 to 70C) 1 Humidity 0 to 85% RH, non-condensing Temperature Vibration 1 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave EMC Immunity to EN 50082-2 (heavy industrial) 1 1 Emissions to EN 50081-2 (heavy industrial) Front panel NEMA 4X when mounted with gasket provided Agency approval CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and pulse input/power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution degree 2 Overvoltage Category II 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-117 1.6 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls Dimensions Approximate Dimensions in Inches (mm) Eclipse Flow Models 2.19 (55.6) BATCH 1 1 1.772 0.02 (45 0.6) PGM PGM View Enter Edit Start Stop Reset 4.04 (102.6) 3.622 0.031 (92.00 0.8) Panel Cutout 1 1 Max. Panel Thickness 0.190 (4.83) 1 1 3.63 (92.2) 1 3.31 (84.1) 1 1 0.27 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-118 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Fusion Integrated Machine Control 1.7 Contents Fusion Integrated Machine Control Description Fusion Integrated Machine Control Standards and Certifications . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V13-T1-120 V13-T1-120 V13-T1-121 V13-T1-123 1 1 1 1 1 Learn Online 1 1 1 1 1 1 Fusion Integrated Machine Control Product Description The Fusion(R) Integrated Machine Control has advanced features, including a five-preset high speed counter with pre-warn, a totalizer with preset, a batch counter with preset and a ratemeter with high and low setpoints. Unique to the count control world, the Fusion has five output relays (rather than two), along with two transistors and two analog setpoint or follower outputs. Its ten available parameter sets of pre-loaded values are useful as recipes, for job-stacking or for a variety of application-specific purposes. 1 Features The Fusion has a multi-line alphanumeric display which can be programmed to show text messages, logicgenerated prompts, alarms and machine status. Up to eight screens can be shown or optionally locked out. Count and time presets can be made view-only or editable. Preset entry is achieved with simple 0-9 keys on the front panel rather than complicated scrolling methods. The Fusion's real time clock/calendar may be displayed and/or used to time and date stamp printouts. With its ladder logic, the Fusion is actually a 26 I/O controller, making it a complete control for many machines and processes, integrating the functions of external timers, pushbuttons, power supplies, indicating lights, control relays and other components in the same box. User-configurable operator interface with back-lit LCD display and 18-button tactile feedback keypad High speed counter with five presets and pre-warn, totalizer, batch counter and ratemeter 10 parameter sets 13 digital inputs (2) 4-20 mA inputs (2) 0-10V input (3) Form C, 2 Form A, 2 NPN transistor, (1) 4-20 mA, and (1) 0-10V outputs RS-232 and RS-485 serial communications 100-line ladder logic processor for ultimate flexibility Configuration software included NEMA 4X enclosure 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-119 1.7 1 Counters, Panel Meters, Tachometers and Timers Fusion Integrated Machine Control Features and Benefits Feature Customer Benefit 1 High speed count functions; including scaling, main counter, five presets, pre-warn, totalizer, batch and rate "Canned" count functions offer flexibility and ease of setup in the desired units of measure. 1 High speed counting independent of ladder scan time Precise and repeatable output response for high performance applications. Flexible display with selectable character sizes (large, medium, small), run screens and ladder triggered messages Minimizes confusion and operator errors as information can be tailored to what they need and in their language. Maintenance/management data can be separated. Different character sizes allow optimization of information displayed. Machine status information can be displayed allowing operators to take action. Simple front panel layout and keypad. Four soft keys and six function keys can be used as inputs 1 Ease of use for operator. Numeric keypad allows for ease of preset and machine parameter entry. Function keys and soft keys allow easy and quick access to information and/or parameters needed by the operator and don't require using additional inputs. Eliminates cost associated with external pushbuttons and inputs. Parameter sets 1 Allows for predefined recipes/jobs to be preloaded for the operator. Simplifies operator interaction and minimizes errors. Programmable relay logic 1 Well understood programming method that allows flexibility in control functionality. Easy to tailor the control to various applications. 26 I/O (digital and analog) Provides application flexibility. Analog inputs allow monitoring key process parameters. Analog outputs allow interfacing to drives and other control products. Integrated solution Reduced overall control costs, installation and commissioning. More flexible and capable than traditional count/control solutions but less complex than many PLC solutions. Windows(R) and front panel programming Ease of programming and configuration control. RS-232 and RS-485 serial communication ports Allow for direct connection to PC for programming, connection to Modbus(R) networks, interface to serial printer. Robust type 4X package. DIN cutout and short depth 2.82 in (71.6 mm) Suited for wet applications. Same cutout as the President Series--easing the migration. Short depth minimizes the cost and size of the machine panel or control enclosure. 1 1 1 1 1 1 1 1 Input power: 85-265 Vac 50/60 Hz or 10-30 Vdc models Greatly reduces models required for different control voltages. Output power: 12 Vdc at 75 mA, 24 Vdc at 100 mA 1 Eliminates the need for an external power supply for encoders, analog transducers, etc. Depluggable screw terminals 1 Allows for ease of wiring and removal of control. Terminals are different sizes to error-proof installation. Non-volatile memory and capacitor backed real time clock Don't have to worry about a battery failing down the road. 1 Real time clock Allows for control functions to be performed on day/time and allows for date/time stamping on printouts. 1 UL, cUL and CE marked Ease of meeting machine agency requirements and robust EMC performance. 1 1 1 Standards and Certifications UL and cUL listed CE marked 1 1 1 1 Product Selection 1 57550400 Fusion Integrated Machine Control Description Catalog Number 1 Fusion integrated machine control--10-30 Vdc power 57550400 1 Fusion integrated machine control--85-265 Vac power 57551400 Fusion configuration software 57590400 1 1 V13-T1-120 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Fusion Integrated Machine Control 1.7 Technical Data and Specifications 1 General Specifications Description 1 Specification 1 Environmental Operation Temperature Indoor use to 2000m 1 32 to 122F (0 to 50C) operating -4 to 158F (-20 to 70C) storage Humidity 1 0 to 85% RH, non-condensing Vibration 2.5 Gs, 30-200 Hz Shock 30 Gs, 11 ms half sinewave EMC EN61326:1997 1 1 All I/O lines except RS-485 <30m Front panel Type 4X indoor use only, when mounted with gasket provided Safety UL and cUL listed, CE compliant 1 1 Input Power AC model 85-265 Vac, 47-63 Hz, 20 VA; isolation 2300 Vac DC model 10-30 Vdc, 15 VA 1 1 Inputs Control 1 Number 10 Impedance 4.75k ohms to +5 Vdc 1 High 3.5-30 Vdc Low 0-1.0 Vdc 1 Thresholds 1 Counter Number Three (including reset) Impedance 4.75k ohms to +5 Vdc or 26.9k ohms to ground 1 High 3.5-30V 1 Low 0-1.5V, or 200 mV p-p to 50V rms at 26.9k ohms (mag pickup) Thresholds Response 1 140 Hz or 14 kHz for sinking, push-pull or mag pickup inputs 1 60 Hz or 6 kHz for sourcing only inputs All frequencies based on 50-50 duty cycle 6 kHz maximum sustained count speed 1 Number 4 1 Type 4-20 mA and two 0-10 Vdc Accuracy 0.5% FS and 200 PPM/C Analog Impedance 100 ohms (current input), 1.27M ohms (voltage input) Overrange 45 mA max. (current input), 20V max. (voltage input) 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-121 1.7 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Fusion Integrated Machine Control General Specifications, continued Description Specification Outputs Power (AC input model only) 24 Vdc 15%, 100 mA max., short-circuit protected 12 Vdc 10%, 75 mA max., short-circuit protected Relays Number 3 (Form C), 2 (Form A) Contacts 5A, 250 Vac, 30 Vdc Isolation 2300 Vac Transistors Number 2 1 Type NPN Darlington 1 Ratings 150 mA max. ON current, 30 Vdc max. OFF voltage Analog 1 Number 2, short-circuit protected Type 4-20 mA (<450 ohms), 0-10V (>2500 ohms) 1 Accuracy 0.5% FS and 200 PPM/C Common mode voltage rating 250 Vac Isolation 2300 Vac 1 1 1 1 1 1 1 RS-232 Connector DB-9S Polarity DCE Baud rate 1200-19200 RS-485 Connector Six-wire RJ-12 phonejack Baud rate 1200-19200 Data Retention Program data Type Non-volatile Duration 100 years, no batteries 1 Real time clock 1 Charge time Three minutes Retention 1-5 days 1 1 1 1 1 1 Type Capacitor Human Interface Display Type 128 x 64 pixel graphic LCD with LED backlight Figure size 0.12 in (3 mm) high, 21 characters per line, 6 lines maximum 0.24 in (6 mm) high, 10 characters per line, 3 lines maximum 0.35 in (9 mm) high, 7 characters per line, 2 lines maximum Keys Number 18 Type Membrane switches with tactile feedback Real time clock format Seconds, minutes, hours, day and date 1 1 1 1 1 V13-T1-122 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Fusion Integrated Machine Control 1.7 Dimensions Approximate Dimensions in Inches (mm) 1 Fusion Integrated Machine Control 1 1 1 5.33 (135.5) 1 01 L1 L2 1 xxxx 2 3 1 2 2 RUN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 16 17 P/N 57551 400 1 1 1 F1 F2 1 F4 1 F3 1 F5 1 F6 4 5 6 1 2 3 3.42 (86.9) 2.57 (65.3) 1 1 5 6.18 (157) 0.38 (9.7) 1 2.50 (63.5) 2.79 (70.8) 1 1 1 2.6770.028 (680.7) 1 1 5.4330.039 (1381) 1 1 Note 1 Recommended panel cutout is 0.375 in (9.5 mm) max. panel thickness. 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-123 1.8 1 Counters, Panel Meters, Tachometers and Timers Special Function Controls Contents President Position Controller Description 1 Page President Position Controller Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 V13-T1-125 V13-T1-127 Learn Online 1 1 1 1 1 1 1 President Position Controller 1 Product Description Features The 58868400 closed-loop position control provides digital output signals (run, direction and fast/slow) to a drive to cause a motor-driven tool to be positioned along a single axis. These signals can also be used to control values in a hydraulic positioning system. Typically, a quadrature encoder, coupled to the drive mechanism, provides the feedback signal to the position control. Up to five destinations can be automatically sequenced through in a move-and-dwell process, or the operator can select a single destination for move-and-stop positioning. 1 1 1 1 1 1 1 1 1 1 1 1 6-digit, LED display, 14 mm (0.56 in) high characters 4 move registers plus home 2 Form C relays and 5 NPN transistor outputs 28 kHz count speed 5 dwell time settings 15 Vdc at 100 mA power output Standards and Certifications Manual or automatic operation Programmable offset, prewarn and kerf values Backlash compensation Programmable high/low limits 20 mA current loop communications NEMA 4X front panel Product Selection 58868400 1 President Position Control Description Catalog Number Single-axis position control 58868400 1 1 1 1 1 V13-T1-124 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL Listed Counters, Panel Meters, Tachometers and Timers Special Function Controls 1.8 Technical Data and Specifications 1 General Specifications Description 1 Specification 1 Power Input AC operation 120/240 Vac (10%, -20%), 47 to 63 Hz 1 DC operation 11 to 16 Vdc (0.7A maximum) Power consumption 18 watts maximum 1 15 Vdc (+1, -2), 100 mA maximum 1 Operating temperature 32 to 130F (0 to 55C) 1 Storage temperature -40 to 160F (-40 to 71C) DC Power Output Output Environment Operating humidity 85% relative, non-condensing Rating NEMA 4 rating when mounted with gasket provided 1 1 Control Input Response START/STOP 1 mS Go home input 5 mS Load position 5 mS Reference input 1.7 mS 1 1 1 Input Voltage 1 Count Inputs High 10.5 to 24.5 Vdc Low 0 to 4.5 Vdc 1 High 3.8 to 15.0 Vdc Low 0 to 1.2 Vdc 1 Control Inputs 1 Input Impedances Count inputs 6.8k ohms to +15 Vdc (2.2 mA at 0 Vdc) Control inputs 2.2k ohms to +5 Vdc (2.3 mA at 0 Vdc) 1 Form C contacts 1 Relay Outputs (2) Type Load voltage Up to 240 Vac or 280 Vdc Load current 5A resistive, 1.5A at 80% PF 1 1 Transistor Outputs (5) Type NPN open collector with surge protection Load voltage 30 Vdc maximum Load current 300 mA maximum Saturation 1.5V maximum at 300 mA Latency 150 +5 S/1 kHz input speed 10 S 1 1 1 Communication Type 1 20 mA loop (active transmit, passive receive) Speed 110, 300 or 1200 baud Parity Odd, even, space Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit (110 baud uses 2 stop bits) Load voltage 30 Vdc maximum Load current 300 mA maximum Saturation 1.5V maximum at 300 mA Latency 150 +5 S/1 kHz input speed 10 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-125 1.8 1 1 1 1 1 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Special Function Controls General Specifications, continued Description Input Frequency Specification 1 Quadrature selection 2 X1 3 High speed 28 kHz Low speed 150 Hz X2 3 High speed 14 kHz Low speed 150 Hz X4 3 High speed 7 kHz Low speed 150 Hz Position Control Features Setpoints Four move setpoints plus one home setpoint Range (all setpoints) -99999 to 999999 1 Decimal point Four positions, programmable 1 Dwell times Five, one for each setpoint Dwell time range 00.01 to 99.98 seconds Scale factor range 0.00100 to 9.999999 Accuracy 100% when the position control is operated within the specified speeds and input voltages 1 1 1 1 Notes 1 Only function 60 and the double jumper affect the maximum input speed. The scale factor does not affect the input speed. 2 The maximum input frequency only on the selected quadrature operation. 3 Low speed jumper installed. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-126 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Special Function Controls 1.8 Dimensions Approximate Dimensions in Inches (mm) 1 President Position Controller 1 5.80 (147.3) 1 5.38 (137) 1 POSITION RUN 1 2 3 4 5 6 7 8 9 MOVE K1 1 10 11 12 13 14 15 16 17 18 IN1 IN2 K2 DWELL MOVE HOME 1 2 3 4 5 RECALL FAST JOG+ JOG- POSITION 6 7 8 9 0 +/DWELL FUNCTION START STOP ENTER 3.04 (77.2) 2.62 (66.7) + K1 NO C NO Recommended Panel Cutout: 5.43 W x 2.68 H (137.9 x 68.1) Gaskets Pt. #28720-216 (Standard) Pt. #28720-217 Note: 1 gasket standard. 2nd gasket and Panel spacer optional. Use of optional spacer and gasket Spacer reduces unit depth from 5.91 (150) Counter to 5.38 (137.3). Front Spacer Kit Pt. #38820-400 Bezel 1 K2 AC INPUTS 19 20 21 22 23 24 25 26 27 NC C NO 28 29 30 31 32 33 34 35 36 1 1 5.91 (150) 1 1 1 1 1 Panel mounting clip fits into four square holes in side of counter. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-127 1.9 1 Counters, Panel Meters, Tachometers and Timers Temperature Controls Contents TC Series Description 1 Page TC Series Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . Special Control Function Inputs . . . . . . . . . . . . . . . 1 1 V13-T1-129 V13-T1-129 V13-T1-130 1 1 1 1 1 1 1 TC Series 1 Product Description Features and Benefits Temperature controllers for a wide range of applications including heat treating, baking, packaging, furnace control, and chillers. 1 1 1 1 1 Universal temperature inputs allow user to select from PT100 or J, K, T, E, B, R, S, N, L thermocouples without modification to the unit Advanced fuzzy modified PID technology minimizes overshoot/undershoot and allows quick and accurate responses Standards and Certifications Fast sampling rate of up to five times per second ensures accuracy in fast processes Standard IP65 front panel (TC48) provides protection in wash-down and other challenging environments 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-128 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com UL recognized CSA certified CE marked RoHS compliant Counters, Panel Meters, Tachometers and Timers Temperature Controls 1.9 Product Selection TC24411100 TC484120001 TC964110100 1 TC Series 1 Description Normally Stocked Item Catalog Number Temperature control, 24 x 48 mm, two relay out, 90-250 Vac Yes TC24411100 Temperature control, 24 x 48 mm, SSR driver/relay out, 90-250 Vac Yes TC24412100 Temperature control, 48 x 48 mm, one relay out, relay alarm, 90-250 Vac Yes TC484110101 Temperature control, 48 x 48 mm, SSR driver out, 90-250 Vac Yes TC484120001 Temperature control, 48 x 48 mm, SSR driver out, relay alarm, 90-250 Vac Yes TC484120101 Temperature control, 48 x 48 mm, analog out, relay alarm, 90-250 Vac Yes TC484130101 Temperature control, 96 x 48 mm, one relay out, relay alarm, 90-250 Vac Yes TC964110100 Temperature control, 24 x 48 mm, two relay out, 11-26 Vac/Vdc -- TC24511100 Temperature control, 48 x 48 mm, one relay out, relay alarm, 11-26 Vac/Vdc -- TC485110101 Process control, 24 x 48 mm, analog/relay out, 90-250 Vac -- PC24463100 Temperature control, 48 x 48 mm, analog out, relay alarm, 90-250 Vac -- TC24413100 1 1 1 1 1 1 1 1 1 1 1 Technical Data and Specifications General Specifications Description 1 Specification 1 Power Power 90-250 Vac, 47-63 Hz, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx4) 11-26 Vac/Vdc, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx5) 1 Resolution 18 bits 1 Sampling rate 5 times/second Temperature effect 1.5 V/C for all inputs except mV input Input 1 3.0 V/C for mV input 1 T/C 0.2 V/ohm 1 Three-wire RTD 2.6C/ohm of resistance difference of 2 leads Two-wire RTD 2.6C/ohm of resistance sum of 2 leads Sensor lead resistance effect Burn-out current 200nA Common mode rejection ratio (CMRR) 120dB Normal mode rejection ratio (NMRR) 55dB Sensor break detection Sensor open for TC, RTD and mV inputs, sensor short for RTD input, below 1 mA for 4-20 mA, below 0.25V for 1-5V input Sensor break response time Within 4 seconds for TC, RTD, and mV inputs; 0.1 second for 4-20 mA and 1-5V inputs 1 1 1 1 1 Output Relay rating 2A/240 Vac; 200,000 life cycles for resistive load Pulsed voltage Source voltage 5V, current limiting resistance of 66 ohms 1 Resolution 15 bits 1 Output regulation 0.02% for full load change Output setting time 0.1 sec. (stable to 99.9%) Linear output Isolation breakdown voltage 1000 Vac Temperature effect 0.01% of SPAN/C Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 1 1 1 V13-T1-129 1.9 1 Counters, Panel Meters, Tachometers and Timers Temperature Controls General Specifications, continued Description Specification 1 Alarm 1 Alarm relay Form C rating; 2A/240 Vac; 200,000 life cycles for resistive load Alarm functions Dwell timer, deviation high/low alarm, deviation band high/low alarm, PV high/low alarm 1 Alarm mode Normal, latching, hold, latching/hold Dwell timer 0.1 to 4553.6 minutes 1 Environmental and Physical 1 Operating temperature 14 to 122F (-10 to 50C) Storage temperature -40 to 140F (-40 to 60C) 1 Humidity 0-90% RH (non-condensing) Altitude 2000m max. 1 Pollution Degree 2 Insulation resistance 20M ohms min. (at 500 Vdc) 1 Dielectric strength 2000 Vac, 50/60 Hz for 1 minute 1 Vibration resistance 10-55 Hz, 10 m/s2 for 1 minute Moldings Flame resistant polycarbonate Dimensions TC96 = 1.88 in (48 mm) (W) x 3.77 in (96 mm) (H) x 3.15 in (80 mm) (D) 1 TC48 = 1.88 in (48 mm) (W) x 1.88 in (48 mm) (H) x 4.56 in (116 mm) (D) 1 1 1 1 TC24 = 1.96 in (50 mm) (W) x 1.04 in (26.5 mm) (H) x 4.35 (110.5 mm) (D) Special Control Function Inputs Input Characteristics Type Range Accuracy at 25C Input Impedance J -120 to 1000C (-184 to 1832F) 2C 2.2M ohms K -200 to 1370C (-328 to 2498F) 2C 2.2M ohms 1 T -250 to 400C (-418 to 752F) 2C 2.2M ohms E -100 to 900C (-148 to 1652F) 2C 2.2M ohms 1 B 0 to 1800C (32 to 3272F) 2C (-200 to 1800C) 2.2M ohms R 0 to 1767.8C (32 to 3214F) 2C 2.2M ohms 1 1 1 S 0 to 1767.8C (32 to 3214F) 2C 2.2M ohms N -250 to 1300C (-418 to 2372F) 2C 2.2M ohms L -200 to 900C (-328 to 1652F) 2C 2.2M ohms 1 PT100 (DIN) -210 to 700C (-346 to 1292F) 0.4C 1.3k ohms PT100 (JIS) -200 to 600C (-328 to 1112F) 0.4C 1.3k ohms 1 mV -8 mV to 70 mV 0.05% 2.2M ohms mA -3 mA to 27 mA 0.05% 70.5 ohms V -1.3V to 11.5V 0.05% 650k ohms 1 1 1 1 1 1 1 1 V13-T1-130 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 Contents Accessories and Encoders Description Accessories and Encoders DIN Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . C-Face Ring Tachometer . . . . . . . . . . . . . . . . . . Magnetic Pickup Sensor and Gear . . . . . . . . . . Rotary Contactor--ES9513/ES9513RS . . . . . . . Measuring Wheels . . . . . . . . . . . . . . . . . . . . . . Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . Cube Style Shaft Encoders . . . . . . . . . . . . . . . . Heavy-Duty Shaft Encoders. . . . . . . . . . . . . . . . Right Angle, Size 20 Shaft Encoders . . . . . . . . . Page V13-T1-132 V13-T1-133 V13-T1-134 V13-T1-134 V13-T1-135 V13-T1-135 V13-T1-136 V13-T1-139 V13-T1-142 1 1 1 1 1 1 1 1 1 1 1 Accessories and Encoders Product Overview Features Eaton offers a variety of accessories to complement our counting and control product offering. 1 Easy integration with Eaton counters 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-131 1.10 1 1 1 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders DIN Rail Adapter Product Description Features Allows mounting of 1/32 DIN front panel mounted products to DIN rail inside panel. 1 1 1 1 1 1 For panel-mounting all DIN size counters, timers and process indicators 0.94 x 1.89 in (24 x 48 mm) or 1.97 x 0.98 in (50 x 25 mm) Cut-out: 0.98 x 1.97 in (25 x 50 mm) For snap-on fitting to 35 mm top hat DIN rails Construction-- Mounting panel for counter: Chrome-plated sheet steel Top hat DIN rail adapter: Glass fiber reinforced polymide Product Selection DIN Rail Adapter A2448DINADAPT 1 Description Catalog Number DIN rail adapter for 1/32 DIN panel mount devices A2448DINADAPT 1 1 1 1 Dimensions Approximate Dimensions in Inches (mm) DIN Rail Adapter 1 3.98 (101.0) 1.98 (50.4) 1.77 (45.0) 1 1 1 1.77 (45.0) 1 2.95 (75.0) 1.0 (25.4) 3.29 (83.5) 1 1 1 1 2.76 (70.0) 1 1 1 1 1 1 1 V13-T1-132 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 C-Face Ring Tachometer Product Description Features Provides sensing of motor speed when used with ratemeter/tachometer. 1 5-16 Vdc input power NPN transistor output, 20 mA sinking capacity 60 pulses per resolution Zero speed pickup 1 Variety of motor C-face sizes: 56, 184, 254, 256 39 to 225F (4 to 107C) operating temperature 1 1 1 Product Selection 47007_ 1 C-Face Sensor 1 Description Normally Stocked Item Catalog Number Motor size 56C Yes 47007056 Motor size 143TC, 145TC, 182C, 184C Yes 47007184 Motor size 184TC, 213C, 215C, 254C Yes 47007215 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-133 1.10 1 1 1 1 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders Magnetic Pickup Sensor and Gear Product Description Sensor ideal for use with a variety of Eaton counters to show motor/shaft speed or measurement. 1 Features Magnetic Pickup 0.25 in (6.4 mm) diameter Ideal for tachometer and rate control applications -40 to 298F (-40 to 148C) operating temperature Output is AC signal, amplitude proportional to speed of target 10 ft (3m) cable attached L-mounting bracket included 1 1 1 Product Selection Magnetic Pickup Sensor and Gear 47004400 and 28433400 1 Description Catalog Number Magnetic pickup 47004400 30-tooth gear for magnetic pickup 28433400 1 1 1 1 1 1 1 1 1 Rotary Contactor--ES9513/ES9513RS Product Description Features Simple reed switch circuit to provide a contact closure for counting. 1 1 No power required Reed switch output models for electronic counters Contact closure output Leaf switch output models for electromechanical counters 5/16 in (7.9 mm) double shaft, 2400 rpm max. at 1:1 ratio 12 in (304.8 mm) wire leads 1 1 Product Selection 1 3910040 Rotary Contactor Description Rotary Contactor Catalog Number 1 12:1 ratio reed switch output ES9513RS 39100400 1 10:1 ratio reed switch output ES9513RS 39100401 1:1 ratio reed switch output ES9513RS 41100400 1 1:3 ratio reed switch output ES9513RS 41100401 1:3.28 ratio reed switch output ES9513RS 41100402 1 1:10 ratio reed switch output ES9513RS 41100403 1:10 ratio leaf switch output ES9513 40892400 1 1:1 ratio leaf switch output ES9513 40891400 1:3 ratio leaf switch output ES9513 40892401 1 1 V13-T1-134 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com 30-Tooth Gear Accessory 1.6 in (41 mm) diameter 0.275 in (7 mm) bore diameter Mounting set screw included Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 Measuring Wheels Product Description Features Measuring wheel mounts to Eaton encoders and rotary contactor to allow for accurate measurement. 1 For use with shaft encoders and rotary contactors 12 in (304.8 mm) meter circumference 1 Urethane, rubber and knurled edges available 1 1 1 Product Selection Measuring Wheel 1 1 Ft Circumference Measuring Wheels Normally Stocked Item Description 1 Catalog Number 5/16 in bore, urethane rim Yes 20144300KIT 3/8 in bore, urethane rim -- 20144303KIT 5/16 in bore, rubber rim Yes 20154300KIT 3/8 in bore, rubber rim Yes 20154301KIT 5/16 in bore, knurled rim Yes 20156300KIT 3/8 in bore, knurled rim -- 20156301 1 1 1 1 1 1 Mounting Bracket 1 Product Description 1 Mounting bracket for Eaton D-Series counters and rotary contactors. 1 1 1 Product Selection Mounting Bracket 1 Mounting Bracket Description Normally Stocked Item Catalog Number Mounting bracket Yes 40460400 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-135 1.10 1 1 1 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders Cube Style Shaft Encoders Product Description Features Provides accurate pulse outputs for use with PLCs and counters. 1 1 1 1 1 1 5-28 Vdc input power 80 mA current draw NPN transistor output, 250 mA sinking capacity Square wave output; (50-50 duty cycle) Single channel and quadrature models Up to 600 pulses per revolution 3/8 in (9.5 mm) double ended shaft ABEC three double sealed ball bearings Tapped holes for face or base mounting Military style connector Product Selection Cube Shaft Encoder Cube Shaft Encoders Description 1 Normally Stocked Item Catalog Number Single Channel 1 60 pulses per revolution -- 38150060 100 pulses per revolution Yes 38150100 1 120 pulses per revolution -- 38150120 600 pulses per revolution Yes 38150600 1 Quadrature 1 60 pulses per revolution -- 38151060 100 pulses per revolution Yes 38151100 120 pulses per revolution -- 38151120 600 pulses per revolution Yes 38151600 Description Normally Stocked Item Catalog Number Mounting bracket -- 40460402 1 1 1 1 Accessory Mounting Bracket 1 1 Mounting Bracket 1 Note 1 40460400 is shown, 40460402 has additional mounting plate for encoders. 1 1 1 1 1 1 1 1 1 1 V13-T1-136 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 Technical Data and Specifications 1 General Specifications Description 1 Specification 1 Electrical Input (38150) 1 Voltage 9 to 16 Vdc Current 60 mA max. at 16 Vdc Ripple 2% 1 5 to 28 Vdc 1 Input (38151) Voltage Current 60 mA nom., 100 mA max. Ripple <2% 1 1 Output Type Current sinking transistor with 1.5k ohms pull-up Sinking current 100 mA max. Max. voltage at 100 mA 1.3 Vdc Blocking voltage 1 1 40 Vdc max. Polarity Positive Wave shape Square wave 1 1 Pulse rate 38150 1 to 20,000 pulse per second 38151 1 to 10,000 pulse per second Rise time <1 S Pulses per rev. 1 to 1270 Accuracy Within 0.1 1 1 1 Environmental Operating temperature 32 to 167F (0 to 75C) Vibration 3 Gs at 5 to 1000 cps Shock 20 Gs, 10 ms 1 1 Mechanical Shaft speed 6000 RPM max. Shaft rotation CW or CCW Bearings Sealed ball bearings Starting torque 0.1 oz-in Moment of inertia 0.0025 ounce in-sec2 Radial loading 40 pounds operating Axial loading 30 pounds operating Shaft 3/8 in (9.5 mm) dia. Operating life Up to 100,000 hours, depending on speed Housing Aluminum with black anodized finish. Sealed against dust, oil, vapor and moisture. Mounting Bottom or front face Weight 1 lb (0.5 kg) max. Connector MS-3102E-14S-6P Mating connector MS-3106A-14S-6S with 10 ft (3m) shielded cable and termination for electronic controls 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-137 1.10 1 1 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders Dimensions Approximate Dimensions in Inches (mm) Cube Shaft Encoders 1 2.25 (57.2) 1 0.50 (12.7) 0.33 (8.3) 1 1 1 1 1 0.06 (1.6) 0.70 (17.8) 1 0.25 (6.4) 2.25 (57.2) 45 0.38 (9.5) (4) 6.32 (160.5) Tapped Holes 0.25 (6.4) Deep on 2.00 (50.8) B.C. (Same Mtg. Holes on Opposite End and Bottom) 2.25 (57.2) (4) 6.32 (160.5) Tapped Holes 0.25 (6.4) Deep on 2.00 (50.8) B.C. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-138 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 Heavy-Duty Shaft Encoders Product Description Features Provides accurate pulse outputs for use with PLCs and counters. 1 5-28 Vdc input power 80 mA current draw NPN transistor output, 250 mA sinking capacity Square wave output Single channel and quadrature models 1 3/8 in (9.5 mm) single ended shaft ABEC 3 double sealed ball bearings Tapped holes for face or base mounting Military style connector 1 1 1 1 Product Selection Heavy-Duty Shaft Encoder 1 Heavy-Duty Encoder Normally Stocked Item Catalog Number 60 pulses per revolution Yes 48370060 100 pulses per revolution -- 48370100 120 pulses per revolution Yes 48370120 600 pulses per revolution Yes 48370600 60 pulses per revolution Yes 48371060 100 pulses per revolution Yes 48371100 100 pulses per revolution Yes 48371120 600 pulses per revolution Yes 48371600 Description 1 1 Single Channel 1 1 1 Quadrature 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-139 1.10 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1 Technical Data and Specifications 1 General Specifications 1 1 1 1 1 1 Description Specification Electrical Input Voltage 5 to 28 Vdc Current 60 mA nom., 100 mA max. Ripple -2% Output Type Current sinking transistor with 1.5k ohms pull-up Sinking current 100 mA max. Max. voltage at 100 mA 1.3 Vdc Blocking voltage 40 Vdc max. 1 Polarity Positive Wave shape Square wave (50-50 duty) 1 Pulse rate 0 to 20,000 pulse per second 1 1 Rise time <1 S Pulses per rev. 1 to 1270 Accuracy Within 0.1 or 6 arc minutes Environmental 1 Operating temperature 32 to 167F (0 to 75C) Vibration 3 Gs at 58 to 500 cps 1 Shock 50 Gs, 11 ms duration Mechanical 1 Shaft speed 6000 RPM max. 1 Shaft rotation CW or CCW Bearings Sealed ball bearings 1 Starting torque 1.0 oz-in Radial loading 50 pounds operating 1 Axial loading 35 pounds operating 1 Shaft 3/8 in (9.5 mm) dia. Housing Aluminum with black painted finish. Sealed against dust, oil, vapor and moisture. 1 Mounting Provisions for bottom or front face Weight 3.25 lbs (1.47 kg) max. 1 Connector MS-3102E-14S-6P Mating connector MS-3106A-14S-6S with 10 ft (3m) shielded cable and termination for electronic controls (Part No. 29665-300) 1 Connector, clamp and bushing only (Part No. 29729-300) 1 1 1 1 1 1 1 1 V13-T1-140 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 Dimensions Approximate Dimensions in Inches (mm) 1 Heavy-Duty Encoder 1 3.00 (76.2) 1.50 (38.1) 0.70 (17.8) 0.81 (20.6) 1 3.00 (76.2) 0.06 (1.6) 1.50 (38.1) 1 1.13 (28.6) 1 1.18 (30.0) 1.50 (38.1) 1 3.00 (76.2) 1 1.50 (38.1) 45 Mounting Holes (Typical) 1/4-20, 0.55 (14.0) Deep on 2.00 (50.8) B.C. 6.00 (152.4) 1 Dia. 0.38 (9.5) Shaft with Flat 2.00 (50.8) Bolt Hole Circle 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-141 1.10 1 1 1 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders Right Angle, Size 20 Shaft Encoders Product Description Features Provides accurate pulse outputs for use with PLCs and counters. 1 1 1 1 1 5-28 Vdc input power 100 mA current draw NPN transistor output, 100 mA sinking capacity Quadrature output, two square waves Up to 1800 pulses per revolution Flange mounting 3/8 in (9.5 mm) shaft diameter Double shielded ball bearings Military style connector Product Selection 38159_ Right-Angle Shaft Encoder, Size 20 1 Description Catalog Number 100 pulses per revolution 38159100 1 120 pulses per revolution 38159120 38159600 1 600 pulses per revolution 1000 pulses per revolution 381591000 1800 pulses per revolution 381591800 1 1 Encoder Cables 1 Description Catalog Number 1 10 ft encoder cable 29665300 15 ft encoder cable 29665315 1 20 ft encoder cable 29665320 25 ft encoder cable 29665325 1 30 ft encoder cable 29665330 35 ft encoder cable 29665335 1 40 ft encoder cable 29665340 1 50 ft encoder cable 29665350 75 ft encoder cable 29665375 100 ft encoder cable 29665400 1 1 1 1 1 1 1 1 1 1 1 V13-T1-142 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 1.10 Technical Data and Specifications 1 General Specifications Description 1 Specification 1 Electrical Input 1 Voltage 5 to 28 Vdc (4.75 min., 28.0 max.) Current 100 mA max. with no output load Ripple -2% peak to peak at 5 Vdc 1 Type Quadrature current sinking transistors with 2.2k ohms pull-up 1 Sinking current 100 mA max. Max. voltage at 100 mA 1.3 Vdc Output Blocking voltage 40 Vdc max. Polarity Positive Wave shape Square wave (50-50 duty cycle) Pulse rate 0 to 100,000 pulses per second Noise immunity Tested to BS EN6100-4-2; IEC801-3; BS EN61000-4-4; DDENV 50141; DDENV 50204; BS EN55022 (with European compliance option) Symmetry 180 electrical degrees 18 Quadrature phasing 90 electrical degrees 36 Minimum edge separation 54 electrical degrees 1 1 1 1 1 1 1 Rise time <1 S Pulses per rev. 1 to 1270 Accuracy Within 0.1 1 32 to 158F (0 to 70C) 1 Environmental Operating temperature Vibration 20 Gs at 50 to 500 cps Shock 75 Gs, 11 ms 1 1 Mechanical Shaft speed 8000 RPM max. Shaft rotation CW or CCW Bearings Double shielded ball bearings Starting torque 1.0 oz-in typical Moment of inertia 5.2 x 104 ounce in-sec2 Radial and axial loading (80 lbs max.) 20-40 lbs for bearing life of 1.5 x 109 revolutions Maximum acceleration 1 x 105 radians/second2 Shaft 0.375 in (9.5 mm) dia. Housing Black non-corrosive finish. Sealed against dust, oil, vapor and moisture. Mounting Flange mount Weight 11 oz (312g) Connector MS-3102E-14S-6P Mating connector MS-3106A-14S-6S with 10 ft (3m) shielded cable and termination for electronic controls (Part No. 29665-300) 1 1 1 1 1 1 1 1 Connector, clamp and bushing only (Part No. 29729-300) 1 1 1 1 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-143 1.10 1 1 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders Dimensions Approximate Dimensions in Inches (mm) Right-Angle Shaft Encoder 1 6-32 UNC 0.25 (6.4) Deep 4 x 90 Dia. 2.0 (50.8) B.C. 1 3/8" 0.3745 (9.512) 1 0.75 (19.1) 1 0.63 (15.9) 1 1.18 (30) 2.06 1.75 (52.3) (44.5) 0.05 (1.3) 1 1 1.41 (35.9) 2.06 (52.3) 1 Side Mount MS Style Connector Shaft Size Dia. 0.16 (4.0) Through 4 x 90 Dia. 2.48 (62.9) B.C. 0.87 (22.1) 0.80 (20.3) 2.0 (50.8) 0.05 (1.3) 0.30 (7.6) 0.60 (15.2) 2.0 (50.8) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-144 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers Accessories 1.11 Spare Parts 1 Style Number Description 36172202KIT Front panel gasket 48369200KIT Mounting clip 28748200KIT Screw for mounting clip 48355110KIT Terminal strip--10 position 48355112KIT Terminal strip--12 position 58802420 Desk kit for President Series (part numbers 5882-5886 and 5782) 29729300 Accessories connector 56460400 Sequence control 57044200KIT 6460 keypad 57740290KIT Mounting clip 46066220KIT Gasket 1 1 1 1 1 1 48720623KIT Ambassador front keypad 28720400KIT Kit mounting Ambassador Series 48720614KIT Label position control 48720280KIT Label membrane switch, Ambassador 1 1 1 1 General Accessories Style Number Description 48160400 Input signal conditioner 48160440 Timer module (selectable time base oscillator) 48160451 Analog to frequency converter 499904xx(08/16) Simultaneous input processor (anti-coincidence counting from multiple input devices) 8 inputs/16 inputs 38091400 RC surge suppressor 3605945x(0/1) Solid-state I/O modules (AC input and output, DC input and output) 0 = DC, 1= AC 36059201 Plug-in-module, 10-32 Vdc or 15-32 Vac input 36059202 Plug-in-module, 12-140 Vac output 1 1 1 1 1 1 Fusion Style Number Description 47590200 Front overlay label 1 1 Ambassador Family Accessories Style Number Description 48183401 Desk mount kit (enclosure for flat surface mounting) 58801460 RS-485 to RS-232 communications converter 58801461 RS-485 to RS-232 communications converter (Europe) 38145400 RS-485 interconnect kit 38146xxxx RS-485 cable--xxxx is length in feet, specify with 4 digits (0500 = 500 ft) 1 1 1 1 1 President 1 Style Number Description 28720302KIT Mounting kit 28720301KIT Kit mounting clip and gasket 48720410 5881-0 President replace label 48720420 Label kit 48720430 Kit label replace Lexan to Mylar 48720440 5884 President replace label 48720450 5885 President replace label 48720460 5886 President replace label 1 1 1 1 1 Note 1 Call EatonCare. 1 Volume 13--Counters, Timers and Tachometers CA08100015E--January 2013 www.eaton.com V13-T1-145