GXE600 Series Single output 600W Programmable Medical and ITE Power Supplies Features Convection Cooled Up to 95% Efficient RS-485 Read-Write Communication (Modbus RTU protocol) Constant Voltage & Constant Current Modes Monitoring & Programming Functions Digital or Analog Programming Seven Year Warranty Key Market Segments & Applications Specifications Model AC Input Voltage range (1) Inrush Current (100 / 200VAC) Power Factor (100 / 200VAC) Input Current (115/230VAC) (Typ) Nominal Output Voltage Maximum Output Current Output Voltage Range (Manual Adjust) Output Voltage Range (Via Programming) (2) Current Limit Set Point (Via Programming) (2) Temperature Coefficient Regulation Overcurrent Protection (3) Overvoltage Protection (3) Hold Up Time (Typ at 100% load) Leakage Current (max) Standby Voltage Vsb) Remote Sense Remote On/Off Power Fail Signal AC Fail Signal Parallel Operation Operating Temperature (-40C start up) Storage Temperature Operating Humidity (non condensing) Storage Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Certifications Line Dips Conducted & Radiated EMI Immunity Weight (Typ) Size (WxHxD) MTBF - Telcordia SR-332 issue 3* Warranty VAC A A VDC A VDC VDC A %/C V ms mA C C %RH %RH VAC M g mm Hours Yrs GXE600-24 GXE600-48 85 - 265VAC (47 - 63Hz). Withstands 300VAC for 5s 40 / 40A Meets EN61000-3-2 (0.99 / 0.95) 6.1 / 3.1A 24V 48V 25A 12.5A 19.2 - 28.8V 38.4 - 57.6V 4.8 - 28.8V 9.6 - 57.6V 5 - 28.8A 2.5 - 14.4A <0.02%/C See Model Selector >28.8A >14.4A 28.8 - 31.2V 57.6 - 62.4V 20ms <0.3mA 4.8V - 5.2V 1A Yes Isolated opto-coupler. Unit off when current is flowing through the opto diode Signal is high when the output voltage drops due to AC loss or OCP, OVP, OTP Signal goes high when the AC input is not present Yes, up to five units Convection: -20 to +70C, derate linearly to 50% load from 50 to 70C (4) -40 to +85C 20 - 90%RH 10 - 90%RH Convection or forced air cooling Input to Ground 2kVAC (1xMOPP), Input to Output 4kVAC (2xMOPP), Output to Ground 1.5kVAC (1xMOPP), Output to Signals 100VAC for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour /HD version: Designed to meet MIL-STD-810G 514.7 Category 4, 10 < 196.1m/s2 /HD version: Designed to meet MIL-STD-810G 516.7 Procedure I, VI IEC/UL/CSA/EN60950-1, IEC/UL/CSA/EN62368-1, IEC/ES/CSA/EN60601-1, IEC/EN62477-1 (OVC III), CE Mark SEMI-F47 (200VAC input) EN55011 / EN55032-B, FCC Class B, VCCI-B IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2, IEC60601-1-2 Ed 4 1300 127 x 41 x 254mm 511,677 hours Seven Years (1) 85Vac: 360W, 100 to <170Vac: 500W, 170V to 265Vac: 600W (Convection cooled). 600W when forced air is applied (see installation manual) (2) Using RS-485 communications or external 1-6V voltage source. See installation manual for details (3) Overcurrent & Overvoltage limits and recovery modes can be set using the RS-485 communications (4) See installation manual for full derating curves *24V output model, 25C ambient, full load, 230VAC input GXE600 Series Model Selector Model GXE600-24 GXE600-48 Output Voltage (V) Max Output Power (W) Load Reg (mV) Line Reg (mV) Ripple Noise (mV) Efficiency (typ) % 115/230 VAC 24 48 600 600 144 288 96 192 150 350 92 / 95 92 / 95 Monitoring and Programming Functions Function Output Voltage Monitor Output Current Monitor Output Voltage Programming Output Current Programming Over Voltage Protection Set Point Over Voltage Recovery Over Current Set Point Over Current Recovery Over Temperature Recovery Remote On/Off Internal Temperature Monitoring Operating Run Time Log Remaining Electrolytic Capacitor Life Alarm History Slew Rate (Rise-time) Control Communication Configuration Product Information Power Fail Signal Threshold Digital (RS-485) Control Analog Control Read back No Read back No Adjustable Adjustable, use a 1-6V external voltage source Adjustable Adjustable, use a 1-6V external voltage source Adjustable Fixed Auto-recovery or manual settings Cycle AC input or use the remote on/off Adjustable Fixed Auto recovery: Constant current, hiccup or foldback Constant current, auto-recovery Latching: Constant current or foldback Cycle AC input or use the remote on/off Cycle AC input or use the remote on/off Yes, enable or inhibit type Yes, enable or inhibit type Yes, -20 to +100oC No Records more than 20 years of data No Indicates hours left No OCP, OVP, OTP, remote on/off, system error No Voltage and current No ID, Baud Rate, Parity Not applicable Model #, serial #, lot #, firmware version Not applicable Adjustable for either output voltage or current Fixed (voltage only) Outline Drawing Options Suffix Blank /A /HD /HDA Description U channel chassis U channel chassis with cover U channel chassis, ruggedized & pcb coating U channel chassis with cover, ruggedized & pcb coating For Additional Information, please visit https://product.tdk.com/info/en/products/power/index.html Revision p9: Jan 2020