GXE600 Series
Features
Convection Cooled
Up to 95% Effi cient
RS-485 Read-Write Communication (Modbus RTU protocol)
Constant Voltage & Constant Current Modes
Monitoring & Programming Functions
Digital or Analog Programming
Seven Year Warranty
Single output 600W Programmable Medical and ITE Power Supplies
Model GXE600-24 GXE600-48
AC Input Voltage range (1) VAC 85 - 265VAC (47 - 63Hz). Withstands 300VAC for 5s
Inrush Current (100 / 200VAC) A 40 / 40A
Power Factor (100 / 200VAC) - Meets EN61000-3-2 (0.99 / 0.95)
Input Current (115/230VAC) (Typ) A 6.1 / 3.1A
Nominal Output Voltage VDC 24V 48V
Maximum Output Current A 25A 12.5A
Output Voltage Range (Manual Adjust) VDC 19.2 - 28.8V 38.4 - 57.6V
Output Voltage Range (Via Programming) (2) VDC 4.8 - 28.8V 9.6 - 57.6V
Current Limit Set Point (Via Programming) (2) A 5 - 28.8A 2.5 - 14.4A
Temperature Coeffi cient %/°C <0.02%/°C
Regulation - See Model Selector
Overcurrent Protection (3) - >28.8A >14.4A
Overvoltage Protection (3) V 28.8 - 31.2V 57.6 - 62.4V
Hold Up Time (Typ at 100% load) ms 20ms
Leakage Current (max) mA <0.3mA
Standby Voltage Vsb) - 4.8V - 5.2V 1A
Remote Sense - Yes
Remote On/Off - Isolated opto-coupler. Unit off when current is fl owing through the opto diode
Power Fail Signal - Signal is high when the output voltage drops due to AC loss or OCP, OVP, OTP
AC Fail Signal - Signal goes high when the AC input is not present
Parallel Operation - Yes, up to fi ve units
Operating Temperature (-4C start up) °C Convection: -20 to +70°C, derate linearly to 50% load from 50 to 70°C (4)
Storage Temperature °C -40 to +85°C
Operating Humidity (non condensing) %RH 20 - 90%RH
Storage Humidity (non condensing) %RH 10 - 90%RH
Cooling - Convection or forced air cooling
Withstand Voltage VAC Input to Ground 2kVAC (1xMOPP), Input to Output 4kVAC (2xMOPP),
Output to Ground 1.5kVAC (1xMOPP), Output to Signals 100VAC for 1 min.
Isolation Resistance MΩ >100MΩ at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour
/HD version: Designed to meet MIL-STD-810G 514.7 Category 4, 10
Shock - < 196.1m/s2 /HD version: Designed to meet MIL-STD-810G 516.7 Procedure I, VI
Safety Agency Certifi cations - IEC/UL/CSA/EN60950-1, IEC/UL/CSA/EN62368-1, IEC/ES/CSA/EN60601-1,
IEC/EN62477-1 (OVC III), CE Mark
Line Dips - SEMI-F47 (200VAC input)
Conducted & Radiated EMI - EN55011 / EN55032-B, FCC Class B, VCCI-B
Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2, IEC60601-1-2 Ed 4
Weight (Typ) g 1300
Size (WxHxD) mm 127 x 41 x 254mm
MTBF - Telcordia SR-332 issue 3* Hours 511,677 hours
Warranty Yrs Seven Years
Specifi cations
(1) 85Vac: 360W, 100 to <170Vac: 500W, 170V to 265Vac: 600W (Convection cooled). 600W when forced air is applied (see installation manual)
(2) Using RS-485 communications or external 1-6V voltage source. See installation manual for details
(3) Overcurrent & Overvoltage limits and recovery modes can be set using the RS-485 communications
(4) See installation manual for full derating curves *24V output model, 25°C ambient, full load, 230VAC input
Key Market Segments & Applications
Revision p9: Jan 2020
GXE600 Series
Outline Drawing
Output Max Output Load Reg Line Reg Ripple Noise Effi ciency (typ) %
Model Voltage (V) Power (W) (mV) (mV) (mV) 115/230 VAC
GXE600-24 24 600 144 96 150 92 / 95
GXE600-48 48 600 288 192 350 92 / 95
Function Digital (RS-485) Control Analog Control
Output Voltage Monitor Read back No
Output Current Monitor Read back No
Output Voltage Programming Adjustable Adjustable, use a 1-6V external voltage source
Output Current Programming Adjustable Adjustable, use a 1-6V external voltage source
Over Voltage Protection Set Point Adjustable Fixed
Over Voltage Recovery Auto-recovery or manual settings Cycle AC input or use the remote on/off
Over Current Set Point Adjustable Fixed
Over Current Recovery Auto recovery: Constant current, hiccup or foldback Constant current, auto-recovery
Latching: Constant current or foldback
Over Temperature Recovery Cycle AC input or use the remote on/off Cycle AC input or use the remote on/o
Remote On/Off Yes, enable or inhibit type Yes, enable or inhibit type
Internal Temperature Monitoring Yes, -20 to +100oC No
Operating Run Time Log Records more than 20 years of data No
Remaining Electrolytic Capacitor Life Indicates hours left No
Alarm History OCP, OVP, OTP, remote on/o , system error No
Slew Rate (Rise-time) Control Voltage and current No
Communication Con guration ID, Baud Rate, Parity Not applicable
Product Information Model #, serial #, lot #, rmware version Not applicable
Power Fail Signal Threshold Adjustable for either output voltage or current Fixed (voltage only)
Model Selector
Monitoring and Programming Functions
Suffi x Description
Blank U channel chassis
/A U channel chassis with cover
/HD U channel chassis, ruggedized & pcb coating
/HDA U channel chassis with cover, ruggedized & pcb coating
Options For Additional Information, please visit