General Performance IEC Inlet Filter
Approvalsn Rated currents up to 20A
n Excellent performance/size ratio
n Optional medical versions (B type)
according to IEC/EN 60601-1
n Snap-in versions (S and S1 type)
n Hot inlet versions (HI type)
n Optional overvoltage protection
(Z type)
Typical applications
The FN 9222 IEC inlet filter combines an
IEC inlet and mains filter with excellent filter
attenuation in a small form factor. Choosing
the FN 9222 product line brings you the rapid
availability of a standard filter associated with
the necessary safety acceptances. Standard
IEC connector filters are a practical solution
helping you to pass EMI system approval in
a short time. A wide selection on amperage
ratings, output connections, mounting
possibilities and filters for medical applications
are designed to offer you the desired solution.
n Exceptional conducted attenuation
performance, based on chokes with high
saturation resistance and excellent thermal
behavior.
n Rear/front or snap-in mounting.
n Wide mounting flanges available.
n Optional medical versions (B type) comply
with the requirements of IEC/EN 60601-1
for creepage and clearance, leakage
current and high potential testing.
n 12 and 15A types with hot inlet available.
n Optional surge pulse protection.
n Different output connections offering
maximum flexibility for assembly.
n Custom-specific versions are available on
request.
n Portable electrical and electronic
equipment
n Small to medium-sized machines and
household equipment
n Single-phase power supplies, switch-mode
power supplies
n Test and measurement equipment
n Medical equipment
n Rack mounting equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 1 to 20A @ 50°C
Approvals by rated current: 1 to 10A (ENEC, CQC)
16A (ENEC, CQC) for 16 and 20A types
1 to 20A (UL, CSA)
High potential test voltage: P –> PE 2000VAC for 2 sec (standard types)
P –> PE 2500VAC for 2 sec (B types)
P –> N 1000VAC for 2 sec (1 to 10A types, not Z types)
P –> N 250VAC for 2 sec (all Z types)
P –> N 1100VDC for 2 sec (16 and 20A types, not Z types)
Protection category: IP40 according to IEC 60529
Temperature range (operation and storage): -25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
(X to XX A, not Z types)
Flammability corresponding to: UL 94V-2 or better
Surge pulse protection (optional): 2kV, IEC 61000-4-5
MTBF @ 40°C/230V (Mil-HB-217F): ≤15A: 3,040,000 hours
≥16A: 2,256,000 hours
Typical electrical schematic
N
PE
P
Line
Cx R 2xL 2xCy
N‘
PE
P‘
Load
Z types
Standard, R and B types
N
PE
P
Line
Cx 2xL 2xCy
N‘
PE
P‘
Load
except HI-types
IEC Inlet Filters