Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
LD6A Signaling Lights
778 www.IDEC.com 1607302105
LD6A LED SignaLight Towers
Unique Striped Design Improves Visibility
Key features of the LD6A LED SignaLight Towers include:
The striped design with non-illuminated area between the lenses
makes the illuminated color very visible.
Unique oval lens shape provides high-visibility from different
directions.
Five different mounting styles available: frame mount, wall mount,
direct mount and pole mount (round or L-shaped bracket).
Clear lens models available to clearly distinguish between illumi-
nated and non-illuminated lenses.
Custom conguration is possible.
Flashing cycle: 1.75Hz (approx. 105 ashes per minute) conforms to
international standard IEC 60073.
Alarm (3.3kHz, 2 different styles) can be heard in 360º degrees.
Adjustable volume (70 to 90dB).
Degree of protection: IP65 Steady units and IP54 Flashing units
(using frame, wall, direct and pole mount with round base), IP23
Steady and Flashing units using pole mount with L-shaped bracket.
(w/L-shaped bracket)
Frame mount
Direct mount Pole mount
(w/Base)
Wall mount
Assembled Products
Mounting
Style Tiers LED Color
Code
Steady Steady/Flashing/Alarm
Specify housing color code in
place of *: B (black),
W (light gray)
Specify illumination color in
place of starting with the
top tier. State the LED color
code from the left.
R (red), Y (yellow), S (blue),
G (green), W (pure white)
Example: When the LED color is
RYGSW => LD6A-5GQW-
RYGSW
Clear lens type also available.
Specify “C” after the LED
color code.
Example:
LD6A-5GQW-RYSGW =>
LD6A-5GQW-RYSGWC
Part Number Weight (approx.) Part Number Weight (approx.)
G: Frame
Mount
1 R, Y, S, G, W LD6A-1GQ*- 220g LD6A-1GZQ*- 310g
2 RY, RG LD6A-2GQ*- 260g LD6A-2GZQ*- 350g
3 RYS, RYG LD6A-3GQ*- 300g LD6A-3GZQ*- 390g
4 RYSG LD6A-4GQ*- 340g LD6A-4GZQ*- 430g
5 RYSGW LD6A-5GQ*- 380g LD6A-5GZQ*- 470g
W: Wall
Mount
1 R, Y, S, G, W LD6A-1WQ*- 225g LD6A-1WZQ*- 315g
2 RY, RG LD6A-2WQ*- 265g LD6A-2WZQ*- 355g
3 RYS, RYG LD6A-3WQ*- 305g LD6A-3WZQ*- 395g
4 RYSG LD6A-4WQ*- 345g LD6A-4WZQ*- 435g
5 RYSGW LD6A-5WQ*- 385g LD6A-5WZQ*- 475g
D: Direct
Mount
1 R, Y, S, G, W LD6A-1DQ*- 185g LD6A-1DZQ*- 275g
2 RY, RG LD6A-2DQ*- 225g LD6A-2DZQ*- 315g
3 RYS, RYG LD6A-3DQ*- 265g LD6A-3DZQ*- 355g
4 RYSG LD6A-4DQ*- 305g LD6A-4DZQ*- 395g
5 RYSGW LD6A-5DQ*- 345g LD6A-5DZQ*- 435g
P: Pole Mount
(with base)
1 R, Y, S, G, W LD6A-1PQ*- 645g LD6A-1PZQ*- 735g
2 RY, RG LD6A-2PQ*- 685g LD6A-2PZQ*- 775g
3 RYS, RYG LD6A-3PQ*- 725g LD6A-3PZQ*- 815g
4 RYSG LD6A-4PQ*- 765g LD6A-4PZQ*- 855g
5 RYSGW LD6A-5PQ*- 805g LD6A-5PZQ*- 895g
K: Pole
Mount
(with
L-shaped
bracket)
1 R, Y, S, G, W LD6A-1KQ*- 640g LD6A-1KZQ*- 730g
2 RY, RG LD6A-2KQ*- 680g LD6A-2KZQ*- 770g
3 RYS, RYG LD6A-3KQ*- 720g LD6A-3KZQ*- 810g
4 RYSG LD6A-4KQ*- 760g LD6A-4KZQ*- 850g
5 RYSGW LD6A-5KQ*- 800g LD6A-5KZQ*- 890g
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
779
800-262-IDEC (4332) USA & Canada
LD6A
Signaling Lights
1607302105
Combination of LED Color and Lens Color
LED Color Color Lens Type Clear Lens Type
R: Red Red lens Clear lens
Y: Yellow Yellow lens Clear lens
S: Blue Blue lens Clear lens
G: Green Green lens Clear lens
W: White Clear lens
For white (W) LED, a clear lens is used in both color and
clear lens congurations.
Mounting Parts Included
Mounting Style Supplied Parts
G: Frame mount M4 screw (4 pcs)*, M4 spring washer (4 pcs)*, M4 plain washer (4 pcs)*, M5 screw (2 pcs),
M5 spring washer (2 pcs), M5 plain washer (2 pcs), bracket (1 pc)
W: Wall mount M4 screw (20 mm) (4 pcs), M4 screw (8 mm) (4 pcs)*, M4 spring washer (8 pcs)*
M4plainwasher (8 pcs)*, M4 nut (4 pcs), bracket (1 pc), gasket (1 pc)
D: Direct mount M5 screw (4 pcs)*, M5 spring washer (4 pcs)*, M5 plain washer (4 pcs)*, M5 nut (4 pcs)*,
O-ring (4 pcs), gasket (1 pc)
P: Pole mount
(with base)
M5 screw (4 pcs), M5 spring washer (4 pcs), M5 plain washer (4 pcs), M5 nut (4 pcs),
O-ring (4 pcs), gasket (1 pc)
K: Pole mount
(with L-shaped bracket) M22 plain washer 2 (pcs), M22 nut (2 pcs), bracket (1 pc)
*For black housing, black screws and washers are supplied. For light gray housing, silver screws and washers are supplied.
Base Module
Style Mounting Style Part Number Notes
Steady Steady/Flashing/Alarm
Frame Mount LD6A-0GQ* LD6A-0GZQ*
A top cap is supplied.
Wall Mount LD6A-0WQ* LD6A-0WZQ*
Direct Mount LD6A-0DQ* LD6A-0DZQ*
Pole Mount (with base) LD6A-0PQ* LD6A-0PZQ*
Pole Mount (with L-shaped bracket) LD6A-0KQ* LD6A-0KZQ*
Specify a housing color code in place of *: B (black), W (light gray)
Do not supply power to the base module without connecting LED modules.
LED Module
Style Lens Part Number LED Color Code
Black Color lens LD9Z-6ALB- R, Y, S, G, W
Clear lens LD9Z-6ALB- C R, Y, S, G
Light gray Color lens LD9Z-6ALW- R, Y, S, G, W
Clear lens LD9Z-6ALW- C R, Y, S, G
Specify an LED color code in place of : R (red), Y (yellow), S (blue), G (green), W (white)
When using white (W) with a clear lens, order LD9Z-6ALB-W (black housing) or LD9Z-6ALW-W (light gray housing).
Center Set Screw
Item Part Number Notes
1 tier LD9Z-6AC1
A plain washer and spring washer are supplied.
2 tiers LD9Z-6AC2
3 tiers LD9Z-6AC3
4 tiers LD9Z-6AC4
5 tiers LD9Z-6AC5
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
LD6A Signaling Lights
780 www.IDEC.com 1607302105
Ordering Examples
[Ex. 1] When ordering LD6A-3PQW-RYG as sub-component parts, specify the following:
Pole mount (with base), steady, light gray housing, 3 tiers, color lens LED modules with Red, Yellow, and Green LED
Base module (pole mount with base, steady, light gray housing) LD6A-0PQW 1 piece
LED module (red LED with color lens, light gray housing) LD9Z-6ALW-R 1 piece
LED module (yellow LED with color lens, light gray housing) LD9Z-6ALW-Y 1 piece
LED module (green LED with color lens, light gray housing) LD9Z-6ALW-G 1 piece
Center screw set (3 tiers) LD9Z-6AC3 1 piece
[Ex. 2] When ordering LD6A-5WZQB-RYSGWC as sub-component parts, specify the following:
Wall mount, steady/ashing/alarm, black housing, 5 tiers, clear lens LED modules with Red, Yellow, Blue, Green, and Pure white LED
Base module (wall mount, steady/ashing/alarm, black housing) LD6A-0WZQB 1 piece
LED module (red LED with clear lens, black housing) LD9Z-6ALB-RC 1 piece
LED module (yellow LED with clear lens, black housing) LD9Z-6ALB-YC 1 piece
LED module (blue LED with clear lens, black housing) LD9Z-6ALB-SC 1 piece
LED module (green LED with clear lens, black housing) LD9Z-6ALB-GC 1 piece
LED module (pure white LED with clear lens, black housing) LD9Z-6ALB-W 1 piece
Center screw set (5 tiers) LD9Z-6AC5 1 piece
Replacement Parts
Item Description Part Number Notes
Top Cap
Black LD9Z-6ATB
A top cap is supplied with a base module.
Light gray LD9Z-6ATW
L-shaped Bracket Metal
(chrome-plated) LD9Z-6AK Two plain washers and two nuts are supplied.
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
781
800-262-IDEC (4332) USA & Canada
LD6A
Signaling Lights
1607302105
Specications
Specications
Safety Standards IEC60947-5-1, EN60947-5-1, UL508,
CSA C22.2 No.14
Operating Temperature –25 to +55ºC (no freezing)
Operating Humidity 45 to 85% RH (no condensation)
Storage Temperature –40 to +75ºC (no freezing)
Overvoltage Category III (IEC60664-1)
Impulse Withstand
Voltage 800V (IEC60947-1)
Insulation Resistance 100 MΩ minimum (500V DC megger)
Dielectric Strength Between live and dead parts: 1000V AC, 1 minute
Pollution Degree 3
Corrosion Immunity Atmosphere free from corrosive gases
Vibration Resistance Operating extremes: 10 to 55Hz, amplitude 0.5 mm
Shock Resistance Operating extremes: 147 m/s2, 6 shocks each in 6 axes
Degree of Protection
(IEC60529)
Steady frame mount, wall mount, direct
mount, pole mount with base IP65
Steady pole mount with L-shaped bracket IP23
Flashing/
Alarm
frame mount, wall mount, direct
mount, pole mount with base IP54
Flashing/
Alarm pole mount with L-shaped bracket IP23
Housing Color Black, Light gray
Material
Housing: ABS resin
Lens: AS resin
Pole: Steel (nickel-chrome plated)
Pole base: Diecast aluminum
Wire 22AWG
Functional Specications
Rated Insulation Voltage 60V
Operating Voltage 24V AC/DC ±10%
Rated Voltage (Ue) 24V AC/DC
LED Color Code R (red), Y (yellow), S (blue), G (green), W (white)
LED
Illumination Color R, Y S, G W
Rated Current (per tier) 25mA 30mA 20mA
Power Consumption
(pertier) 0.6W 0.75W 0.5W
LED Life (Note)
Approx. 30,000 hours (until brightness is reduced
to 50% of the initial value in a 25ºC operating
environment)
Flashing Cycle (IEC60073) Approx. 105 ashes per minute (1.75 Hz)
Alarm
Alarm Cycle Alarm 1: approx. 700 times per minute
Alarm 2: approx. 35 times per minute
Current Draw 110mA max.
Inrush Current AC: 400mA max. DC: 250mA max.
Alarm Volume 70 to 90dB, at 1m (volume adjustable)
Acoustic Frequency Approx. 3.3kHz
Note: Life of the LED varies according to operating conditions and environment.
External Contact Ratings
LED
AC Contact Capacity
(per tier)
Current Capacity 100mA min.
Dielectric Strength 35V AC min.
DC Contact Capacity,
Transistor Capacity (per tier)
Current Capacity 100mA min.
Dielectric Strength 35V min.
Leakage Current 0.1mA max.
Alarm
AC Contact Capacity
(per alarm)
Current Capacity 400mA min.
Dielectric Strength 35V AC min.
DC Contact Capacity,
Transistor Capacity
(per alarm)
Current Capacity 300mA min.
Dielectric Strength 35V min.
Leakage Current 0.1mA max.
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
LD6A Signaling Lights
782 www.IDEC.com 1607302105
Dimensions (Steady Light)
Frame Mount Wall Mount Direct Mount Pole Mount (with base) Pole Mount (with L-shaped bracket)
40
60
52.4
40
40
60
53.4
40
60
40
ø70
60
40
ø94
60
40
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
L1980
L2
L31040
L4730
L580
73032
65
65
980
60
80
40
Conduit Port
M20×P1.5
Front Front Front
Dimension Table
Tiers Frame Mount
(L1)
Wall Mount
(L2)
Direct Mount
(L3)
Pole Mount
w/ base (L4) w/ L-shaped bracket (L5)
1 156 156 98 408 372
2 186 186 128 438 402
3 216 216 158 468 432
4 246 246 188 498 462
5 276 276 218 528 492
Panel Cut-Out
Frame Mount Wall Mount Direct Mount* Pole Mount (with base)
Pole Mount
(with L-shaped bracket)
ø22
2-ø11
35
44.0
2-M5
4-ø4.5
46
23
16
Wire Entry
ø15
+1
0
ø54
4-ø5.5
90°
Wire Entry
ø15
Front
4-ø5.5
ø73
4-ø4.5
ø73
90°
Pattern A*Pattern BPattern CPattern D
120°
120°
ø40
3-ø4.5
4-ø5.5
ø54
Wire
Entry
ø15
Wire
Entry
ø15
Wire
Entry
ø15
Wire Entry
ø15
FrontFrontFront
Front
w/ L-shaped
bracket
w/o L-shaped
bracket
*Complies with IEC60947-5-1.
Wiring Example (Steady Light)
Mechanical Contacts NPN Transistors PNP Transistors
Fuse
1A Power supply
24V AC/DC Power supply
24V DC
Power supply
24V DC
Power supply line:
Yellow
Power supply line:
Yellow
Power supply line:
Yellow
Red
Yellow
Green
Blue
Pure Whit
e
Red
Yellow
Green
Blue
Pure White
Red
Yellow
Green
Blue
Pure White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
External contact
for steady light
(–)
(–)
(+)
(+)
Fuse
1A
External transistor
for steady light
External transistor
for steady light
Fuse
1A
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
783
800-262-IDEC (4332) USA & Canada
LD6A
Signaling Lights
1607302105
Dimensions (Steady/Flashing/Alarm)
Frame Mount Wall Mount Direct Mount Pole Mount (with base) Pole Mount (with L-shaped bracket)
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
2517.4
12.6
52.4
40
60
40
40
60
40
53.4
60
40
40
60
60
40
ø94
L1900
65
L2
65
L3960
650 L4
L580
32650
900
ø70
60
80
40
Conduit Port
M20×P1.5
FrontFront Front
Dimension Table
Tiers Frame Mount
(L1)
Wall Mount
(L2)
Direct Mount
(L3)
Pole Mount
w/ base (L4) w/ L-shaped bracket (L5)
1 228 228 170 480 444
2 258 258 200 510 474
3 288 288 230 540 504
4 318 318 260 570 534
5 348 348 290 600 564
Panel Cut-Out
Frame Mount Wall Mount Direct Mount* Pole Mount (with base)
Pole Mount
(with L-shaped bracket)
ø22
2-ø11
35
44.0
2-M5
4-ø4.5
46
23
16
Wire Entry
ø15
+1
0
ø54
4-ø5.5
90°
Wire Entry
ø15
Front
4-ø5.5
ø73
4-ø4.5
ø73
90°
Pattern A*Pattern BPattern CPattern D
120°
120°
ø40
3-ø4.5
4-ø5.5
ø54
Wire
Entry
ø15
Wire
Entry
ø15
Wire
Entry
ø15
Wire Entry
ø15
FrontFrontFront
Front
w/ L-shaped
bracket
w/o L-shaped
bracket
*Complies with IEC60947-5-1.
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
LD6A Signaling Lights
784 www.IDEC.com 1607302105
Wiring Example (Flashing Light and Alarm)
Mechanical Contacts NPN Transistors PNP Transistors
Flashing COM Brown
Power Gray
Power: Yellow Fuse 1A Power supply
24V AC/DC
Red
Yellow
Green
Blue
Pure White
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
Alarm 1: Purple
Alarm 2: Light Blue
External contact
for steady light/alarm
External contact
for flashing light
(–)
(+)
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
Alarm1: Purple
Alarm 2 Light Blue
Red
Yellow
Green
Blue
Pure White
External contact
for steady light/alarm
External contact
for flashing light
Flashing COM Brown
Power Gray
Power: Yellow Fuse 1A Power supply
24V DC
LED Red: Red
LED Yellow: Orange
LED Blue: Blue
LED Green: Green
LED
Pure White
: White
Alarm1: Purple
Alarm 2 Light Blue
Red
Yellow
Green
Blue
Pure White
Flashing COM Brown
Power Gray
Power: Yellow
(+)
(–)
Power supply
24V DC
Fuse 1A
External contact
for steady light/alarm
External contact
for flashing light
Safety Precautions
Turn off the power to the LD6A before mounting, removing, wiring or as-
sembling the LED module. Make sure the wiring is done correctly otherwise
electrical shock or re may result.
Mount the LD6A on a solid surface not subject to vibrations.
Do not mount the LD6A upside-down or horizontally.
Do not leave the LD6A without a cap or unassembled.
Install the supplied gasket, otherwise the waterproof seal will be
compromised.
Do not apply any chemicals that may corrode the plastic materials.
If the LD6A is subjected to strong vibrations, the hexagon socket screw may
become loose. Take measures to prevent loosening. (See the gure below.)
2-M4 holes for hexagon socket
set screws
recommended tightening torque:
1.1 to1.2 Nm
Do not loosen any screws if the tightening torque is not specied.
Instructions
Mounting
See drawing below regarding the mounting of the LD6A.
For panel cut-out dimensions, see pages 9 and 10.
Postion the LD6A to make sure the alarm sound is the loudest. (Steady/ash-
ing/alarm type)
Frame Mounting
1. Insert two nuts in the frame, and attach the bracket using two M5 screws.
Recommended tightening torque: 2.6 to 2.7 N·m
2. Mount the LD6A to the bracket using four M4 screws.
Recommended tightening torque: 1.6 to 1.7 N·m
Frame (Note)
Frame Nut (Note)
Bracket
Plain Washer
Spring Washer
M5 Screw
M4 Screw, Spring Washer, Plain Washer
Note: See table below for typical examples of frames and nuts. Consult the manufacturer of the frame
for the installation method of the frame nut.
Examples of recommended frames and frame nuts
Frame Size Frame Frame Nut Manufacturer
30 mm* SFF-302
SFB-001
SFB-4B5
SFB-101 SUS
Corporation
(Japan)
40 mm SFF-402
SFB-008
SFB-4A5
SFB-108
*The mounting bracket for the housing is 40 mm.
When using a frame mount type, be sure to use
exible conduit, otherwise the waterproof seal will
be compromised.
Refer to the “Example of Flexible Conduit” shown on
the right.
Gland
Conduit
Conduit por
t
(M20×P1.5
)
Example of Flexible Conduit
Conduit Port Size M20
Gland AL16/M20/A/BL
Conduit PAFS16BL
Manufacturer Adaptaex
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
785
800-262-IDEC (4332) USA & Canada
LD6A
Signaling Lights
1607302105
Wall Mounting
1. Make four tapped holes in the mounting panel and mount the bracket
and gasket using four screws (M4 x 20).
Recommended tightening torque: 1.6 to 1.7 N·m
2. Mount the LD6A to the bracket using four screws (M4 x 8).
Recommended tightening torque: 1.6 to 1.7 N·m
Panel
Nut
Gasket
Bracket
Plain Washer
Spring Washer
M4 Screw (20 mm)
M4 Screw (8 mm), Spring Washer, Plain Washer
Direct Mounting
Recommended tightening torque: 2.6 to 2.7 N·m
Pane
l
M5 Screw
Spring Washer
Plain Washer
O-ring
Base
Gasket
Nut
Pole Mounting (with base)
The pole mount type can be installed in four ways. The recommended mounting
method (pattern A from page 9 or 10) is described below.
Recommended tightening torque: 2.6 to 2.7 N·m (M5 screw)
Pole Mounting (with L-shaped bracket)
1. Using L-shaped bracket
Recommended tightening torque: 10 to 11 N·m (M10)
Recommended tightening torque: 25 to 26 N·m (M22)
2. Not using L-shaped bracket
Remove the bushing, hexagonal nut (M22), plain washer, and L-shaped
bracket from the LD6A and install in the following order: plain washer, hex-
agonal nut (M22), and bushing.
Recommended tightening torque: 25 to 26 N·m (M22)
1. Using L-shaped bracket 2. Not using L-shaped bracket
Hexagonal
nut
(M22)
Hexagonal
bolt
(M10)
Hexagonal
nut
(M10)
Spring washer
Plain washer
Plain washer
Bushing
Hexagonal nut
(M22)
The parts marked with * are not supplied and should be provided by the user.
Replacement and Addition of LED Modules
Make sure to turn power off.
Insert a at screwdriver into the cap recess as shown below, lift up the cap,
and remove with your hands. Use a at screwdriver with maximum 1-mm
thick and 7-mm wide tip.
Remove the center screw before reassembling the LED modules.
When assembling the LED modules, make sure to align the recess of the cap
with the recess of the LED module. Otherwise, damage may result.
Recommended tightening torque: 0.4 to 0.5 N·m.
Insert flat screwdriver into recess
1
23
Recess
Recess
Recess
Recess
LED module
Top Cap
Gasket
Note the correct orientation when assembling the LED modules.
Tighten the screws to the recommended tightening torque. The LED module
may be damaged if the screw is loose during operation.
Do not touch the metal plug on the LED module. Otherwise, LED elements
maybe damaged due to static electricity.
Use a maximum of 5 tiers.
Select the correct screw length depending on the number of tiers.
Do not remove the gasket from the LED module. Otherwise, the waterproof
seal will be compromised.
Wiring
For wiring, see the wiring diagrams on pages 782 and 784.
Incorrect wiring may damage the internal circuit.
Be sure to insulate unused wires.
Connect a 1A fuse to the power line as shown in the Wiring Examples on
pages 782 and 784.
Use a UL listed external fuse holder.
Use a class 2 power supply only.
When using LED modules of the same color for two or more tiers, determine
contact capacity in referencet to the LED current, because only one wire is
used to light all tiers of the same color.
Do not apply voltage to ashing (brown) lines.
Do not connect ashing (brown) line to the power lines. The internal circuit
may be damaged.
Do not turn on steady and ashing circuits simultaneously.
Do not turn on alarms 1 and 2 simultaneously.
Pole Stand
4-M5 Mounting Hole
(recommended)
3-M4 Mounting Hole
4-M4 Mounting Hole
4-M5
Mounting
Hole
M5 Screw
O-ring
Pole Stand
Gasket
Panel
Plain Washer
Spring Washer
Nut
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
LD6A Signaling Lights
786 www.IDEC.com 1607302105
Wire Color
Wire Color Steady Steady, Flashing, Alarm
Red LED Module – Red LED Module – Red
Orange LED Module – Yellow LED Module – Yellow
Blue LED Module – Blue LED Module – Blue
Green LED Module – Green LED Module – Green
White LED Module – White LED Module – White
Purple Alarm 1
Light Blue Alarm 2
Brown Flashing COM
Gray Power Line
Yellow Power Line Power Line
For information on external contacts, see “External Contact Ratings” on page 781.
Alarm Volume Adjustment
Move the volume adjustment to the right or left to change the volume.
When the adjustment lever is all the way to the right the volume is at its
maximum.
The adjustment lever may be damaged if forced open or closed.
Max.
Min.
Alarm volume
adjustment lever
High Temperature Limitations
The external temperature cannot exceed 50ºC when all tiers are lit at the same
time in the following combinations:
1. Three tiers
Two or more tiers of blue and green (example: Red-Green-Blue,
Green-Green-Red)
2. Four or ve tiers (example: Red-Yellow-Green-White, Red-Yellow-Blue-Green-
White)