Model 53 Low Cost Load Cell DESCRIPTION Model 53 load cells are bonded foil strain gage transducers term stability and reliability under severe operating conditions. designed for cost efficient production and testing applications The Model 53 compression-only load cell has an integral load (i.e. press calibration). Engineered compression force button machined as part of the load cell. The Model 53 must be measurements up to 50K lb., this model achieves a maximum mounted on a smooth flat surface for proper operation. Three non-linearity of 0.5 % full scale. Precision gaging techniques tapped holes are provided for mounting. and a stainless steel construction provides excellent long- FEATURES * 5 lb to 50K lb * Stainless steel * Mini footprint * Button-style design * mV/V output Model 53 PERFORMANCE SPECIFICATIONS Characteristic Measure Load ranges5 5 lb to 50K lb Linearity (max.) 0.5 % full scale Hysteresis (max.) 0.3 % full scale Non-repeatability (max.) 0.1 % full scale Output (tolerance) 2 mV/V (nominal) Operation Compression Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero 0.005 % full scale/F Temperature effect, span 0.01 % full scale/F ELECTRICAL SPECIFICATIONS Characteristic Measure Strain gage type Bonded foil Excitation (calibration) 5 lb to 100 lb 5 Vdc RANGE CODES Range Code Available ranges Range Code Available ranges AT 5 lb DN 3000 lb AV 10 lb DP 4000 lb BL 25 lb DR 5000 lb BN 50 lb DT 7500 lb BR 100 lb DV 10K lb CN 250 lb EJ 15K lb CR 500 lb EL 20K lb CV 1000 lb EN 30K lb DL 2000 lb EP 50K lb DEFLECTIONS AND RINGING FREQUENCIES Capacity (lb) Deflection @ full scale (in) Natural ringing frequency (Hz) Weight with cable g [lb] 5 0.001 2000 59 [0.13] 10 0.001 3000 59 [0.13] 25 0.001 16K 62 [0.136] 50 0.001 21K 63 [0.138] 100 0.001 28K 64 [0.141] 250 0.001 25K 72 [0.158] 500 0.001 32K 72 [0.158] Excitation (calibration) 250 lb to 50K lb 10 Vdc 1000 0.001 42K 75 [0.165] Insulation resistance 5000 Mohm @ 50 Vdc 2000 0.001 53K 77 [0.17] Bridge resistance (tolerance) 350 ohm (nominal) 3000 0.001 27K 137 [0.30] Zero balance (tolerance) 3 % full scale 4000 0.001 31K 138 [0.304] Shunt calibration data Included 5000 0.001 34K 140 [0.306] Electrical termination (std) Teflon cable 1.83 m [5 ft] 7500 0.001 41K 142 [0.313] 10K 0.001 47K 145 [0.32] 15K 0.002 24K 368 [0.811] 20K 0.002 28K 372 [0.820] 30K 0.002 33K 377 [0.831] 50K 0.003 24K 1270 [2.8] MECHANICAL SPECIFICATIONS Characteristic Measure Weight See table Material 17-4 PH stainless steel Maximum allowable load 150 % full scale1 Deflection full scale See table Natural frequency See table WIRING CODES Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output 2 Honeywell * Sensing and Control Low Cost Load Cell MOUNTING DIMENSIONS Ranges lb D1 mm [in] D2 mm [in] H mm [in] L mm [in] A in B mm [in] G mm [in] 5, 10, 25, 50, 100 25,4 [1.00] 5,33 [0.21] 15,75 [0.62] 1,27 [0.05] #4-40 UNC 5,59 [0.22] 19,05 [0.750] 250, 500, 1000, 2000 31,75 [1.25] 8,13 [0.32] 9,91 [0.39] 1,78 [0.07] #6-32 UNC 6,35 [0.25] 25,4 [1.000] 3000, 4000, 5000, 7500, 10K 38,1 [1.50] 10,16 [0.40] 16,0 [0.63] 2,03 [0.08] #6-32 UNC 6,35 [0.25] 31,75 [1.250] 15K, 20K, 30K 50,8 [2.00] 15,24 [0.60] 25,4 [1.00] 3,05 [0.12] #6-32 UNC 6,35 [0.25] 41,28 [1.625] 50K 76,2 [3.00] 19,81 [0.78] 38,1 [1.50] 4,57 [0.18] #6-32 UNC 6,35 [0.25] 60,33 [2.375] OPTION CODES Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10K, 15K, 20K, 30K, 50K lb Temperature compensation 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F Internal amplifiers 2u. Unamplified, mV/V output Electrical termination 6d. Microtec DR-4S-4H 4-pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 6g. Integral cable: Neoprene Special calibration 9a. 10 point (5 up/5 down) 20 % increments @ 68 F 9b. 20 point (10 up/10 down) 10 % increments @ 68 F Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration6 53t. TEDS IEEE 1451.4 module4 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 6h. Integral cable: Silicone 6i. Integral underwater cable3 6v. Phoenix connector on end of cable Honeywell * Sensing and Control 3 Model 53 Low Cost Load Cell NOTES 1. 2. 3. 4. 5. 6. Allowable maximum loads - maximum load to be applied without damage.2 Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. Dimension "H" may increase with option 6i. Consult factory. Maximum temperature is 180 F. TEDS available with integral cable units only. This unit calibrated to Imperial (non-Metric) units. Signature calibration only available as inline module. TYPICAL SYSTEM DIAGRAM In-line amplifiers (used with unamplified units only) Amplifier Output Universal in-line amplifiers UV 5 Vdc UV-10 10 Vdc UBP 0 5 Vdc U3W 4 mA to 20 mA (3-wire) DIN rail mount in-line amplifiers DV-05 0 5 Vdc (3-wire) DA-05 4 mA to 20 mA (3-wire) DV-10 0 10 Vdc (3-wire) Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. WARNING PERSONAL INJURY Customer supplied Chart recorder Alarm panel Data acquisition Computer PLC Model 53 Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifica- Display units SC500 SC2000 SC2001 SC3004 GM NK HH * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. tions, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell's test and measurement products, call +1-614-850-5000, visit http://measurementsensors. honeywell.com, or e-mail inquiries to info.tm@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 008638-4-EN IL50 GLO February 2014 Copyright (c) 2014 Honeywell International Inc. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: 060-0238-05 060-0238-10 060-0240-02 060-0241-04 060-0238-07 060-0239-04 060-0239-08