1
CSM_E3S-X3_DS_E_2_1
Fiber Photoelectric Sensor
E3S-X3
Excellent Detection of Color
Differences
Ordering Information, Ratings, and Specifications
Amplifiers
Model E3S-X3CE4
Item Sturdy model
Appearance
Light source (wave length) Red LED (660 nm)
Power supply voltage 12 to 24 VDC ±10%
Current consumption 50 mA max.
Response time Operate or reset: 1 ms max.
Control output Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.)
Operation indicator Light indicator (red), Stability indicator (green)
Ambient illumination Sunlight: 10,000 lx max.; Incandescent lamp: 3,000 lx max.
Ambient temperature Operating: 25°C to 55°C (with no icing)
Storage: 25°C to 70°C
Ambient humidity Operating: 35% to 85%
Storage: 35% to 95%
Insulation resistance 20 Mmin. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC at 50/60 Hz for 1 minute between current-carrying parts and case
Degree of protection IEC IP66
Material Case: Zinc die-cast
E3S-X3
2
Through-beam and Grooved-type Sensors
* Values in parentheses: when using the E39-F1 Lens Unit
* Values in parentheses: when using the E39-F1 Lens Unit
Fiber Units
Sensing method Through-beam
Feature Long distance General-purpose
Model E32-T11L E32-T12L E32-T21L E32-T22L E32-TC200
E32-TC200B
E32-
TC200B4
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
250 (650) mm *
Opaque:
1.4-mm dia. min.
250 mm
Opaque:
1.4-mm dia. min.
65 mm
Opaque: 0.9-mm dia. min.
120 mm (1 m) *
Opaque:
1-mm dia. min.
120 mm
Opaque:
1-mm dia. min.
Minimum sensing
object (copper
strand) (typical)
0.3-mm dia. 0.2-mm dia.
Ambient operating tempera-
ture 40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min.
Fiber sheath materials Black polyethylene
Sensing method Through-beam
Feature General-purpose Attachment for
E39-F5 Flexible (resists breaking)
Model E32-T22 E32-TC200E
E32-TC200F
E32-
TC200F4
E32-TC200A E32-T11 E32-T21
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
35 mm
Opaque: 0.5-mm dia. min.
120 mm
Opaque:
1-mm dia. min.
120 mm (1 m) *
Opaque:
1-mm dia. min.
35 mm
Opaque:
0.5-mm dia.
min.
Minimum sensing
object
(copper strand)
(typical)
0.1-mm dia. 0.2-mm dia. 0.1-mm dia.
Ambient operating tempera-
ture 40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min. 4 mm min.
Fiber sheath materials Black polyethylene Vinyl chloride
M4 screw 3-mm dia. M3 screw 2-mm dia. M4 screw
90 mm (40 mm)
M4 screw
( ): E32-TC200B4
2-mm dia. M3 screw
90 mm (40 mm)
M3 screw
( ): E32-TC200F4
M3 screw M4 screw M3 screw
E3S-X3
3
: Indicates models that do not allow free cutting.
*1. When using the E39-F1 Lens Unit. Ambient operating temperature specification is the same as the Lens Unit (40 to
200°C).
*2. The sensing distance is 400 mm when a 1.0-mm-wide Slit is attached. The minimum diameter of the sensing object is
0.35 mm. The sensing distance is 300 mm when a 0.5-mm-wide Slit is attached. The minimum diameter of the sensing
object is 0.25 mm. (Use a Slit with 0.5-mm width if the sensing distance is less than 300 mm. The measurements of
distances are shown in the figure on the right.)
*3. For continuous operation, use the products within the temperature ranging from 40°C to 130°C.
Sensing method Through-beam Side-view Through-beam Through-beam
with lens
Feature Curl cable Long dis-
tance
Space sav-
ing
Screw-
mounting
type
Suitable for ex-
plosion-proof
applications
Model E32-TC200C E32-TC200D
E32-TC200D4 E32-T14L E32-T24 E32-T14 E32-T17L
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
100 (600) mm *1
Opaque: 1-mm dia.
min.
100 mm
Opaque: 1-mm dia.
min.
80 mm
Opaque: 1-
mm dia. min.
30 mm
Opaque: 0.5-
mm dia. min.
600 mm
Opaque: 4-
mm dia. min.
5,000 mm
Opaque: 10-mm
dia. min.
Minimum sensing
object (copper
strand) (typical)
0.2-mm dia. 0.1-mm dia. 0.8-mm dia.
Ambient operating tempera-
ture 40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min.
Fiber sheath materials Black polyethylene
Sensing method
Fluorocarbon
polymer-cov-
ered through-
beam
Screen
through-beam
Four-head
through-beam Heat-resistant through-beam Groove type
Feature
Withstands
chemicals and
harsh environ-
ments
Suitable for
detecting over
a 10-mm area
Simulta-
neous de-
tection in
four loca-
tions
Heat resistant
up to 150°C
Heat resistant
up to 300°C
No optical axis
adjustment re-
quired
Model E32-T12F E32-T16 E32-M21 E32-T51 E32-T61 E32-G14
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
550 mm
Opaque: 4-mm dia.
min.
550 mm *2
(Field of view: 10
mm width)
Opaque: 10-mm
dia. min.
100 mm
Opaque: 2-mm dia.
min.
120 mm
Opaque: 1-mm dia.
min.
100 mm
Opaque: 1.5-mm
dia. min.
100 mm (groove
width)
Opaque: 4-mm dia.
min.
Minimum sensing
object (copper
strand) (typical)
0.9-mm dia. 0.4-mm dia. *2 0.3-mm dia. 0.1-mm dia. 0.8-mm dia.
Ambient operating tempera-
ture 30 to 70°C40 to 70°C40 to 150°C *340 to 300°C40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 40 mm min. 25 mm min. 35 mm min. 25 mm min.
Fiber sheath materials
Black polyethylene
covered with
fluorocarbon
polymer
Black polyethylene Fluororesin SUS Black polyethylene
M4 screw
90 mm (40 mm)
M6 screw
(): E32-TC200D4
3-mm
dia.
1-mm
dia.
M14 screw
5-mm dia. M3 screw M4 screw M4 screw
Sensing object
E3S-X3
4
Reflective Sensors : Indicates models that do not allow free cutting.
Sensing method Reflective
Feature Long distance General-purpose
Model E32-D11L E32-D21L E32-D22L E32-DC200
E32-DC200B
E32-
DC200B4
E32-DC200E
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
65 mm
(white paper 3 x
3 cm)
18 mm (white paper 1.5 x 1.5 cm) 50 mm (white paper 3 x 3 cm)
12 mm (white
paper 1.5 x 1.5
cm)
Minimum sensing
object (copper
strand) (typical)
0.015-mm dia. 0.03-mm dia.
Differential travel 20% of sensing distance max.
Ambient operating tempera-
ture 40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min.
Fiber sheath materials Black polyethylene
Sensing method Reflective
Feature General-pur-
pose Flexible (resists breaking) Expandable curl cable Sleeve adjust-
ment
Model
E32-DC200F
E32-
DC200F4
E32-D11 E32-D21 E32-DC200C E32-DC200D
E32-DC200D4
E32-DC9G
E32-DC9G4
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
12 mm
(white paper 1.5
x 1.5 cm)
30 mm
(white paper 3
x 3 cm)
7 mm
(white paper
1.5 x 1.5 cm)
15 mm (white paper 3 x 3 cm)
20 mm
(white paper
1.5 x 1.5 cm)
Minimum sensing
object (copper
strand) (typical)
0.03-mm dia.
Differential travel 20% of sensing distance max.
Ambient operating tempera-
ture 40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min. 4 mm min. 25 mm min.
Fiber sheath materials Black
polyethylene Vinyl chloride Black polyethylene
M6 screw M4 screw 3-mm dia. M6 screw
90 mm (40 mm)
M6 screw
( ): E32-TC200B4
M3 screw
M3 screw M6 screw M3 screw M6 screw
90 mm (40 mm)
M6 screw
( ): E32-DC200D4
90 mm (40 mm)
1.2-mm dia.
( ): E32-DC9G4
E3S-X3
5
: Indicates models that do not allow free cutting.
*1. For continuous operation, use the products within the temperature ranging from 40°C to 130°C.
*2. The sensing distance is 30 to 80 mm for the E39-RSA with a Tape-type Reflector, and 30 to 120 mm for the E39-RSB.
*3. Refer to Dimensions on pages 24 and 25 for the standards for sensing distances.
*4. The ambient operating temperature specification of the Reflectors is the same as that of the E32-R21 and E32-R16.
Sensing method Superfine
reflector Coaxial reflective Side-view reflective
Reflective
covered with
fluorocar-
bon polymer
Heat-resist-
ing reflective
Feature
Minute
object sens-
ing
Positioning accuracy Long
distance
Space
saving
Withstands
chemicals
and harsh
environ-
ments
Heat resis-
tant to 150°C
Model E32-D33 E32-CC200 E32-D32 E3-D14L E32-D24 E32-D12F E32-D51
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
4 mm
(white paper
1.5 x 1.5 cm)
50 mm
(white paper
3 x 3 cm)
20 mm
(white paper
3 x 3 cm)
25 mm
(white paper
3 x 3 cm)
10 mm
(white paper
1.5 x 1.5 cm)
35 mm
(white paper
3 x 3 cm)
40 mm
(white paper
3 x 3 cm)
Minimum sensing
object (copper
strand) (typical)
0.015-mm
dia. 0.03-mm dia.
Differential travel 20% of sensing distance max.
Ambient operating tempera-
ture 40 to 70°C30 to 70°C40 to 150°C
*1
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min. 40 mm min. 35 mm min.
Fiber sheath materials Black polyethylene
Black
polyethylene
covered with
fluorocarbon
polymer
Fluororesin
Sensing method Heat-resistant reflective Retro-reflective (with MSR function) Convergent-reflective
Feature
Heat resis-
tant up to
300°C
Heat resis-
tant up to
400°C
Transparent object detection Detects wafers and small
differences in height
Model E32-D61 E32-D73 E32-R21+E39-R3 *4E32-R16+E39-R1 *4E32-L25 *3E32-L25A*3
Item
Appearance
With
E3S-
X3CE4
Sensing distance
(standard sens-
ing object)
30 mm (white paper 3 x 3 cm)
30 to 200 mm
(with E39-R3 Reflector,
Opaque: 35-mm dia.
min.)
100 to 1,200 mm
(with E39-R1 Reflector,
Opaque: 35-mm dia.
min.) *2
3.3 mm white paper 3 x
3cm)
Minimum sensing
object (copper
strand) (typical)
0.03-mm dia. 0.3-mm dia. 0.6-mm dia. 0.025-mm dia.
Differential travel --- 5% max. of sensing
distance
Ambient operating tempera-
ture 40 to 300°C40 to 400°C40 to 70°C25 to 55°C40 to 70°C
Ambient operating humidity 35% to 85%
Permissible bending radius 25 mm min.
Fiber sheath materials SUS Black polyethylene
3-mm
dia. 0.8-mm
dia. M6 screw 2-mm dia.
6-mm
dia. 2-mm
dia.
6-mm dia. M6 screw
M6 screw M4 screw
1.25-mm
dia.
M6 screw
E39-R3
Reflector
E39-R1
Reflector
E3S-X3
6
Fiber Unit Specifications
Attachments
* Use the Fiber Unit within the specified ambient operating temperature range specified for it. If the Fiber Unit is used with the E32-T61, make sure the ambient
temperature is 40 to 200°C.
Ambient operating temperature No icing or condensation
Ambient operating humidity No condensation
Ambient storage temperature Heat-resistant Fiber Units: 40 to 110°C (with no icing or condensation)
Other Fiber Units: 40 to 70°C (with no icing or condensation)
Ambient storage humidity 35% to 95% (with no icing or condensation)
Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction) 500 m/s2 (50G) for 3 times each in X, Y, and Z directions
Name Small Spot
Lens Unit Long-distance Lens Unit Side-view Unit
Applications
Detection
over 0.5-
mm-dia.
spots
Increasing sensing distance Change detection direction to side view
Model E39-F3A E39-F1 E39-F2
Item
Sensing
method
Applicable fibers E32-D32 E32-T11L E32-TC200
E32-T11
E32-TC200C
E32-T61 E32-T11L E32-TC200
E32-T11
E32-TC200C
E32-T61
With
E3S-
X3CE4
Sensing dis-
tance 6 to 12 mm 650 mm 1,000 mm 600 mm 100 mm 120 mm 100 mm
Standard sens-
ing object
White paper
3 x 3 mm Opaque: 4-mm dia. min. Opaque: 3-mm dia. min.
Directional angle --- 5 to 40°20 to 60°
Differential travel
20% max. of
sensing
distance
---
Ambient temperature 40 to 70°C40 to 200°C *
Material Shaft Aluminum Brass
Lens Optical glass
Reflective Through-beam Through-beam
E3S-X3
7
* Use the Fiber Unit within the specified ambient operating temperature range specified for it. If the Fiber Unit is used with the E32-T61, make sure the ambient
temperature is 40 to 200°C.
Name Lens-equipped Reflective Unit Side-view Re-
flective Unit
Applications Converting through-beam sensors to long distance reflective sensors
Converting
through-beam
to reflective
sensor
Model E39-F3 E39-F5
Item
Sensing
method
Applicable fibers E32-T11L E32-TC200 E32-T61 E32-T11 E32-TC200C E32-TC200A
With
E3S-
X3CE4
Sensing dis-
tance 5 to 90 mm 35 to 50 mm 20 mm
(5 x 5 cm)
Standard sens-
ing object
(white paper)
20 x 20 cm 1.5 x 1.5 cm
Directivity 20% max. of sensing distance
Differential travel 40 to 200°C *40 to 70°C
Material
Shaft Brass ---
Lens Optical glass ---
Base Aluminum Brass
Reflector --- Stainless steel
Beam Spot Characteristics
E39-F3A with E32-D32
Reflective Reflective
16
14
12
10
8
6
4
2
048121620
Insertion distance (mm)
Fiber
E32-D32 d
d
: Insertion
: Focal distance
: Spot diameter (mm)
0.5
0.8
1.0
Focal length d (mm)
E3S-X3
8
Accessories
Name Protective Spiral Tubes
Length (L) 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm
Model E39-
F32A5
E39-
F32A
E39-
F32B5
E39-
F32B
E39-
F32C5
E39-
F32C
E39-
F32D5
E39-
F32D
Item
Appearance
Applicable fiber
E32-DC200E
E32-DC200F(4)
E32-D21
E32-TC200E
E32-TC200F(4)
E32-T21
E32-T21L
E32-TC200
E32-TC200B(4)
E32-T11
E32-T51
E32-T11L
E32-DC200
E32-DC200B(4)
E32-CC200
E32-D11
E32-D51
E32-D11L
Ambient operating
temperature 40°C to 150°C (Do not exceed the operating temperature of the fiber)
Ambient operating
humidity 35% to 85%
Permissible bending
radius 30 mm min.
Tensile strength Between head connector and end cap with tube: 1.5 N·m max.
Tube: 2 N·m max.
Compression load Tube: 29.4 N max.
Name Fiber Cutter Fine-fiber Attachment Fiber Connector Sleeve Bender
Features Used to cut fibers to
desired lengths
Used when inserting fine
fibers into the amp
Used to connect addition-
al fibers for extension
Used to bend fiber
sleeves
Model E39-F4 E39-F9 E39-F10 E39-F11
Item
Appearance
Applicable fiber
All models equipped
with fibers that can be
trimmed.
E32-DC200E, -TC200E
E32-DC200F(4),
-TC200F(4)
E32-D21, -D21L, -D22L,
E32-T21, -T21L, -T22L,
E32-D32, -T22
E32-D24, -T24
E32-D33
E32-R21
E32-DC200, -TC200
E32-DC200B(4),
-TC200B(4)
E32-TC200A
E32-T14, -G14
E32-D11L, -T11L, -T12L
E32-D14L, -T14L
E32-T17L
E32-TC200B(4)
E32-TC200D(4)
E32-DC200F(4),
-TC200F(4)
E32-DC9G(4)
Provided/Order sep-
arately Provided with Fiber Units. Order separately.
Head connector Tu b e End cap
L* Refer to page 13 for information on
attaching the end cap.
E3S-X3
9
Engineering Data (Typical)
Fiber Length vs. Sensing Distance
I/O Circuit Diagrams Conductor colors have been changed as a result of changes in standards. The previous colors are given in brackets.
Note: Not equipped with load short-circuit protection function.
*1. Reverse the polarity of the power supply to switch the output status.
*2. Voltage output (when connected to a transistor circuit)
Connection Conductor colors have been changed as a result of changes in standards. The previous colors are given in brackets.
Connection with S3D2 Sensor Controller
Note: A maximum of two S3D2 Sensors can be connected.
Connection with S3D8 Sensor Controller
Note 1. Operation can be reversed using the -Key.
2. A maximum of eight S3D2 Sensors can be connected.
Through-beam Fiber Units
(Fiber length of 2 m corre-
sponds to 100%)
Fiber Units with Reflective
Sensors
(Fiber length of 2 m corre-
sponds to 100%)
E3X-N@@@, E32-TC200
(Change in rated value)
E3X-N@@@, E32-DC200
(Change in rated value)
Fiber length (m)
Sensing distance (%)
Fiber length (m)
Sensing distance (%)
Sensing distance Y (mm)
Fiber length X (m)
Sensing distance Y (mm)
Fiber length X (m)
Model E3S-X3CE4
Wire color Brown (red) *1Blue (black) *1Brown (red) *1Blue (black) *1
Item Power polarity +0 V 0 V +
State of output transistor Light-ON Dark-ON
Output circuit
Timing charts
Z: Zener Diode (Vz = 30 V)
Photo-
electric
Sensor
main
circuit
Light
indicator
(Red)
Stability
indicator
(Green)
1.5 to
4 mA
12 to 24 VDC
Brown (red) *1
Black
(white)
Blue (black) *1
1.5 to 4 mA
0 V
*2
80 mA max.
Load 1
(relay)
Load 2
Z
H
L
Between brown (red) and black (white)
Between blue (black) and black (white)
Light indicator
(red)
Output
transistor
Load 1
(e.g., relay)
Load 2
Incident light
No incident light
ON
OFF
Operate
Reset
ON
OFF
H
LBetween brown (red) and black (white)
Between blue (black) and black (white)
Light indicator
(red)
Output
transistor
Load 1
(e.g., relay)
Load 2
Incident light
No incident light
ON
OFF
Operate
Reset
ON
OFF
Blue (black)
Black
(white)
Brown (red)
+12 V 0 V
E3S-X
E3S-X
+12 V
Black (white)
Blue (black)
Brown (red)
0 V
L
E3S-X3
10
Adjustment Methods
Sensitivity Adjustment
Adjust the sensitivity so that the indicators appear as shown in the following table during various sensing situations.
Note 1. When the sensitivity is set to achieve the above status, the Sensor will operate stably at all temperatures within the range specified in the ratings.
2. Even if the green indicator turns OFF, if the temperature change is less than ±10°C from when the setting was made, operation will remain stable.
Type Sensing condition Light status Indicator status
Through-beam
Sensing object present
Interrupted
Red indicator: OFF
Green indicator: ON
No sensing object
Incident
Red indicator: ON
Green indicator: ON
Reflective
Sensing object
Sensing object present
Incident
Red indicator: ON
Green indicator: ON
No sensing object
Interrupted
Red indicator: OFF
Green indicator: ON
Detection of
differences in
color or
brightness
Color with good reflection
Incident
Red indicator: ON
Green indicator: ON
Color with bad reflection
Interrupted
Red indicator: OFF
Green indicator: ON
Retro-reflective
Sensing object present Reflector
Interrupted
Red indicator: OFF
Green indicator: ON
Sensing object present Reflector
Incident
Red indicator: ON
Green indicator: ON
Green Red
Green Red
Green Red
Green Red
Green Red
Green Red
Green Red
Green Red
E3S-X3
11
Safety Precautions
This product is not designed or rated for
ensuring safety of persons. Do not use it for
such purpose.
Do not use the product in atmospheres or environments that
exceed product ratings.
Fiber Units
Heat-resistant Fiber Units (E32-D51 and E32-T51)
Make sure that the bending radius 35 mm or greater.
The fibers of these Units cannot be extended using the E39-
F10 Fiber Connector.
The maximum allowable temperature for continuous
operation with these Units is 130°C. It is 150°C for short-
term use.
E32-T14 and E32-G14
These Units may enter the light-ON state if there are reflecting
objects at the ends of the lenses. In this case, attach the black
stickers provided to the ends of the lenses.
E32-T14
E32-G14
E32-L25(A) Wafer Sensors
To ensure correct performance, insert the fiber with a white
line into the emitter-side port of the Amplifier.
Use a tightening torque of 0.78 N·m when mounting the
Sensor head.
Do not use the Sensor in locations subject to splashing
water.
E39-F11 Sleeve Bender
The bending radius of the stainless steel tube should be as
large as possible. The smaller the bending radius becomes,
the shorter the sensing distance will be.
Insert the tip of the stainless steel tube to the Sleeve Bender
and bend the stainless steel tube slowly along the curve of
the Sleeve Bender.
E32-T16 Slit
If a Slit is going to be used, remove the back paper and stick
it on the Sensor head so that the edges are aligned. For a
sensing distance of less than 45 cm, fit the Sensor head with
a 0.5-mm-wide Slit.
Example
Tightening Torque
The tightening force applied to the Fiber Unit should be as
follows:
Use a proper-sized spanner.
WARNING
Precautions for Correct Use
Fiber Units
Stickers
90° max.
10 mm
10 mm
Do not bend here.
1.2-mm dia. max.
R12.5 mm
R7.5 mm
1.3-mm dia. min.
R10 mm
Fiber tip position
mark
Stainless steel tube
R5 mm
Screw-mounting Sensor Cylindrical Sensor
Fiber Units Tightening torque
M3/M4 screw 0.78 N·m max.
M6 screw 0.98 N·m max.
2-mm-dia./3-mm-dia. cylinder 0.29 N·m max.
E32-D14L 0.98 N·m max.
E32-T12F
E32-D12F 0.78 N·m max.
E32-T16 0.49 N·m max.
E32-R21 0.59 N·m max.
E32-M21
Up to 5 mm to the tip:
0.49 N·m max.
More than 5 mm from the tip:
0.78 N·m max.
E32-L25A 0.78 N·m max.
E32-T16's
sensing head
Slit provided
Toothed washers
Spring mounting clip
Nuts
(attachment)
Retaining screw (flat head or sunken head)
(M3 max.)
E3S-X3
12
Cutting Fiber
Insert a fiber into the Fiber Cutter and determine the length
of the fiber to be cut.
Press down the Fiber Cutter in a single stroke to cut the
fiber.
The cutting holes cannot be used twice. If the same hole is
used twice, the cutting face of the fiber will be rough and the
sensing distance will be reduced. Always use an unused
hole.
Use either one of the two holes on the right (refer to the
following figure) to cut a thin fiber as follows:
Fiber Insertion Position
When the Fiber Unit is pressed in, it will first hit the rubber
packing. Keep pressing it in further until it contacts the back
surface.
Securing the Fiber
Tighten the screw to 0.2 N·m with a screwdriver.
Laying the Fiber Unit
Do not pull or press on the Fiber Units. The Fiber Units have
a withstand force of 9.8 N or 29.4 N maximum.
Do not bend the Fiber Unit beyond the permissible bending
radius given under Ordering Information.
Do not bend the edge of the Fiber Units.
Do not apply excess force on the Fiber Units.
The Fiber Head could be broken by excessive vibration. To
prevent this, the following is effective:
1
An attachment
is temporarily
fitted to a thin
fiber before
shipment.
2
Secure the
attachment
after adjusting
the position of it
in the direction
indicated by the
arrow.
3
Insert the fiber
into the E39-F4
to cut.
4
Finished state
(proper cutting
state).
Thin fiber attachment (E39-F9)
Temporarily fitted
E39-F4 Cutter
Two holes for
thin fiber
Three holes for
standard fiber
(2.2-mm dia.)
Note: Insert the fiber in the direction indicated
by the arrow.
Approx. 0.5 mm
Insertion direction
Approx. 12 mm
Rubber packing
Fiber Unit
Element
Set screw
Fiber
Amplifier Unit Fiber Unit
20 mm min.
20 mm min.
Nylon wireholder
Fiber Unit
A one-turn loop can
absorb vibrations.
Tape
E3S-X3
13
Applications
E39-F10 Fiber Connector
Use the following procedure to connect fibers via the Fiber
Connector.
Each Fiber Unit should be as close as possible before they
are connected.
Sensing distance will be reduced by approximately 25%
when fibers are connected.
Only fibers with a 2.2-mm dia. can be connected.
E39-F32@ Protective Spiral Tube
Insert a fiber to the Protective Spiral Tube from the head
connector side (screwed) of the tube.
Push the fiber into the Protective Spiral Tube. The tube
should be straight so that the fiber is not twisted when
inserted. Then turn the end cap of the spiral tube.
Secure the Protective Spiral Tube on a suitable place with
the attached nut.
Use the attached saddle to secure the end cap of the
Protective Spiral Tube. To secure the Protective Spiral
Tube at a position other than the end cap, apply tape to the
tube so that the portion becomes thicker in diameter.
Attachment Units
1 2
Retention unit
Splice
Retention unit
Fiber Unit
Fiber Unit
Fiber Unit
Fiber Unit
Protective spiral
tube
Fiber Unit
Protective spiral
tube
Fiber Unit
Protective spiral
tube
Fiber Unit
Mounting panel
Toothed washer
Hexagon clamping nut
Tu b e
Saddle
End cap
E3S-X3
14
Fiber Customization Service
OMRON provides the following items to support Fiber Units.
For information on available models, delivery, and prices, contact your OMRON sales representative.
Applicable Fiber Units
E32-TC200F (0.9-mm-dia. tube)
E32-TC200B
E32-DC200F (1.2-mm-dia. tube)
E32-DC200B (2.5-mm-dia. tube)
Tolerance: For L 40 mm = ±1.0 mm
For L > 40 mm = ±2.0 mm
(Lengths of 90 mm and 40 mm are standard sizes.)
Applicable Fiber Units
E32-TC200B
E32-TC200F
E32-DC200F
Available Bending Radius (R) and Dimensions L1, L2
(Units: mm)
Note: Tubes cannot be made to dimensions other than those listed above.
An E39-F11 Sleeve Bender (sold separately) can be used to achieve
dimensions other than those given above.
Model Numbers Incorporating the Bending Radius, R, and Dimensions L1 and L2
Specifying L1 Only (Units: mm)
*1. Insert “T” for Through-beam Fiber Units and “D” for Fiber Units with
Reflective Sensors.
*2. Insert the “B” or “F” that appears at the end of the original model number.
*3. Insert “50” if the total length is 50 mm. The total length must not exceed
120 mm.
Specify L2 only (Units: mm)
*1. Insert “T” for Through-beam Fiber Units and “D” for Fiber Units with
Reflective Sensors.
*2. Insert the “B” or “F” that appears at the end of the original model number.
*3. Insert “50” if the total length is 50 mm. The total length must not exceed
120 mm.
Specifying L1 and L2 (Units: mm)
*1. Insert “T” for Through-beam Fiber Units and “D” for Fiber Units with
Reflective Sensor.s
*2. Insert the “B” or “F” that appears at the end of the original model numbers.
Stainless Tubes at Various Lengths
L
Can be made at lengths
between 10 and 120 mm in
increments of 10 mm.
Stainless Tubes with a Bent End
L1 L2 Total length of
SUS tube
RControl No. 1234 S@
R5.0 A10 15 5 10 120 max.
R7.5 B12.5 17.5 7.5 17.5 120 max.
R10.0 C15 20 10 20 120 max.
R12.5 D17.5 22.5 12.5 22.5 120 max.
L1
R
To t a l
length
L2 R
Total
length
Bend at the tip of the tube Bend at the base of the tube
Bending radius
L1 (
±
1)
Model
R5 10 E32- C200 -S A1
15 E32- C200 -S A2
R7.5 12.5 E32- C200 -S B1
17.5 E32- C200 -S B2
R10 15 E32- C200 -S C1
20 E32- C200 -S C2
R12.5 17.5 E32- C200 -S D1
22.5 E32- C200 -S D2
Bending radius
L2 (
±
1)
Model
R5 5E32- C200 -S A3
10 E32- C200 -S A4
R7.5 7.5 E32- C200 -S B3
17.5 E32- C200 -S B4
R10 10 E32- C200 -S C3
20 E32- C200 -S C4
R12.5 12.5 E32- C200 -S D3
22.5 E32- C200 -S D4
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
*1*2*3
Bending radius
L1 (
±
1) L2 (
±
1)
Model
R5
10 5E32- C200 -A13
10 10 E32- C200 -A14
15 5E32- C200 -A23
15 10 E32- C200 -A24
R7.5
12.5 7.5 E32- C200 -B13
12.5 17.5 E32- C200 -B14
17.5 7.5 E32- C200 -B23
17.5 17.5 E32- C200 -B24
R10
15 10 E32- C200 -C13
15 20 E32- C200 -C14
20 10 E32- C200 -C23
20 20 E32- C200 -C24
R12.5
17.5 12.5 E32- C200 -D13
17.5 22.5 E32- C200 -D14
22.5 12.5 E32- C200 -D23
22.5 22.5 E32- C200 -D24
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
*1*2
E3S-X3
15
Sensing Distance (Units: mm)
Applicable Fiber Units (Typical Models)
E32-TC200/-DC200
E32-TC200B/-DC200B
E32-TC200E/-DC200E
E32-TC200F/-DC200F
E32-TC200A
Between 6 and 20 m in increments of 1 m
(Lengths of 2 m and 5 m are standard sizes
(E32-TC200/-DC200 only).)
Model Amplifier
Stan-
dard
product
R5.0 R7.5 R10.0 R12.5
E32-TC200B E3X-NT 290 180 235 255 290
E3X-NM 270 170 220 240 270
E32-TC200F E3X-NT 70 32 70
E3X-NM 65 30 65
E32-DC200F E3X-NT 22 16 22
E3X-NM 20 15 20
Long-fiber Fiber Units
L
E3S-X3
16
Dimensions
Amplifiers
Through-beam Fiber Units (Two Units are used together as a set.)
(Unit: mm)
Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
Mounting Holes
Two, M4
13 dia.
Sensitivity adjuster
Light indicator
Fiber unit
mounting
screw
Two, M4
slotted hexagonal
bolts
Stability indicator Mounting bracket
A (See note.)
Note: The Mounting Bracket can also be used on side A.
Cable:
4.3C x 0.2-mm-dia. (18/0.12 dia.)
vinyl-insulated round cable
Standard length: 2 m
E3S-X3CE4
M2.6×0.45
* Material: Nickel-plated brass
2.2-dia. optical fiber
3.2 3 11
(14) 2,0007
Two hexagon clamping nuts (T = 2.4)
1.4 dia. Two toothed washers (for M4)
M4 x 0.7 sensing head *
E32-T11L
311
(14) 2,000
1.4 dia.
* Material: Nickel-plated brass
2.2-dia. optical fiber
2.4 dia.
3-dia. sensing head *
E32-T12L
2.5
5.5 11
1.8(1.7)
25
10
2,000
* Material: Nickel-plated brass
1-dia. optical fiber
Two hexagon clamping nuts
0.9 dia. Two toothed washers
M3 x 0.5 sensing head *
E39-F9 Fiber attachment
E32-T21L
25
10
(2)
17
22 2,000
12
0.9 dia.
1-dia. optical fiber
1.8 dia.
2-dia. sensing head (stainless steel)
Fiber attachment (E39-F9)
Heat-shrinkable tube
E32-T22L
M2.6×0.45
3.2 3 2.4
14 2,0007
* Material: Nickel-plated brass
2.2-dia. optical fiber
Two hexagon clamping nuts
1.0 dia. Two toothed washers
M4 x 0.7 sensing head *
E32-TC200
E3S-X3
17
3.2
11
90
(40) *1
2.4
2,0007
*1. The value in the parentheses is for the E32-TC200B4.
*2. Material: Nickel-plated brass
2.2-dia. optical fiber
Two hexagon clamping nuts
1.0 dia.
Two toothed washers
M4 x 0.7 sensing head *2
1.2 dia.
max.
Stainless
tube
(SUS304)
E32-T
C
200B
E32-TC200B4
17
22 2,000
12
25
10
0.5 dia.
1-dia. optical fiber
1.4 dia.
Sensing head
(SUS303)
Heat-shrinkable tube
2 dia.
Fiber attachment (E39-F9)
E32-T22
11 2,000
10
25
1.8
5.5
2.5
1-dia. optical fiber
Two hexagon clamping nuts
0.5 dia. Two toothed washers
M3 x 0.5 sensing head *
* Material: Nickel-plated brass
Fiber attachment (E39-F9)
E32-TC200E
1.8
5.5
2.5
2,00011
90
(40) *1
10
25
*1. The value in the parentheses is for the E32-TC200F4.
*2. Material: Nickel-plated brass
1-dia. optical fiber
Two hexagon clamping nuts
0.5 dia.
Two toothed washers
M3 x 0.5 sensing head *
2
0.9 dia.
max.
Stainless
tube
(SUS304)
Fiber attachment (E39-F9)
E32-TC200F
E32-TC200F4
1.0 dia. 2.6 dia.
* Material: Nickel-plated brass
2.2-dia. optical fiber
Two hexagon clamping nuts
Two toothed washers
M3 x 0.5 sensing head *
3 dia.
E32-T200A
2.4 15
(14) 2,000
3.3
M2.6 x 0.45
7
3.2
Sixteen, 0.265 dia.
* Material: Nickel-plated brass
2.2-dia. optical fiber
Two hexagon clamping nuts
Two toothed washers
M4 x 0.7 sensing head *
Protective tube
E32-T11
5.5
2.5
10
25
2,00011
1.8 15
Four, 0.25 dia.
* Material: Nickel-plated brass
1-dia. optical fiber
Two hexagon clamping nuts
Two toothed washers
M3 x 0.5 sensing head *
Protective tube
Fiber attachment (E39-F9)
E32-T21
E3S-X3
18
: Indicates models that do not allow free cutting.
2.2-dia. optical fiber
* Material: Nickel-plated brass
2,000 (when straight)
1.0 dia. M2.6 x 0.45
Sensing head
Two hexagon clamping nuts
Two toothed washers
M4 x 0.7 sensing head *
22 dia.
E32-TC200C
2.2-dia. optical fiber
2,000 (when straight)
*1. The value in the parentheses is for the E32-TC200B4.
*2. Material: Nickel-plated brass
22 dia.
1.0 dia.
1.2 dia. max.
Two hexagon clamping nuts
Two toothed washers
M4 x 0.7 sensing head *
2
Stainless
tube
(SUS304)
*1
E32-TC200D
E32-TC200D4
35
30
1.5
1.5
2.8
1
45°
12
2,000
3 dia.
3-dia. sensing head
(stainless steel) Heat-shrinkable
tube 2.2-dia. optical fiber
Sensing surface
E32-T14L
35 2,000
15
1.50.5
1
15 12
25
10
45°
SUS304
2 dia. 1.4 dia.
1.0-dia. optical fiber
1-dia. Sensing head Heat-shrinkable tube
Fiber Attachment (E39-F9)
E32-T24
10±
0.2
9.2
7
8
2.5
10.5
R3.5
8.2
16 11.2 2,000
2.2-dia. optical fiber
7
Two, 3.2 dia.
Optical axis
Heat resistive ABS
Nitrile rubber
4.4-dia.
lens unit (PMMA)
E32-T14
5
19
23
42
10,000
2.2-dia. optical fiber
10-dia.
lens
(PMMA)
Two hexagon clamping nutsM14 x 1 sensing head (ABS)
E32-T17L
E3S-X3
19
: Indicates models that do not allow free cutting.
20
2,000 100
2.2-dia. optical fiber
4-dia. lens 5-dia. sensing head 4 dia.Fluoride resin
E32-T12F
Sensing head
(ABS)
Lens
(2 x 10)
(PMMA)
Two, M3
6 dia.
2.2-dia. optical fiber
Two, 3.2 dia.
E39-L4
Mounting Bracket
Mounting Holes
0.5-mm Wide Slit Seal
(Supplied with the Unit in pairs)
1-mm Wide Slit Seal
(Supplied with the Unit in pairs)
Black
Black
Two, R2
E32-T16
28
13
23
11 2,000
1.8
Sleeve
M3 x 0.35
sensing head
(SUS303)
Two hexagon clamping nuts
Two toothed washers
Silicone tube * Four, 1-dia.
plastic fibers
* One set of silicone tubes is black while
the other set is gray for easy
identification when they are connected
to the emitter and receiver.
E32-M21
M4 x 0.7 sensing head *
Two hexagon clamping nuts
Two toothed washers
2.2-dia. optical fiber
1.5 dia.
2.85 dia.
* Material: Nickel-plated brass
Note: Resistant temperature is 150°C.
Resistant temperature is 130°C when used continuously.
E32-T51
E3S-X3
20
: Indicates models that do not allow free cutting.
Note:
Section A resists 300°C and section B (which is inserted to the Amplifier) resists 110°C.
The operating temperature of the section to be inserted (marked with *) must be within
the operating temperature range of the Amplifier.
M4 x 0.7 sensing head
(SUS303)
Two hexagon clamping nuts
Two toothed washers
Sleeve
1.0 dia.
5 dia.
4 dia.2.8 dia.
SUS flexible tube Hexagon clamping screw
4 dia.
E32-T61
Mounting Holes
Lens
(PMMA)
Optical axis
Sensing
head
(ABS)
Two, 2.2-dia.
optical fibers
Two, M3
E32-G14
E3S-X3
21
Reflective Fiber Units
5.2 3 2.4
20 2,000
10
Two, 2.2-dia. optical fibers
* Material: Nickel-plated brass
Two, 1.4 dia.
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75 sensing head *
4 dia.
E32-D11L
3.2 2.43
15 2,000
7
10
25
Two, 1-dia. optical fibers
* Material: Nickel-plated brass
Two, 0.9 dia.
Two hexagon clamping nuts
Two toothed washers
M7 x 0.7 sensing head *
Two Fiber Attachments (E39-F9)
E32-D21L
3
15 2,000
25
10
Two, 1-dia.
optical fibers
* Material: Nickel-plated brass
3 dia. sensing head*
2.7 dia.
Two, 0.9 dia.
Two Fiber Attachments (E39-F9)
E32-D22L
4.8 2.43
17 2,000
10
Two, 2.2-dia. optical fibers
Two, 1.0 dia.
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75 sensing head
(ADC)
4 dia.
E32-DC200
2,00017
2.4
5.2
10 90
(40) *1
Two, 2.2-dia. optical fibers
Two, 1.0 dia.
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75 *2 sensing head
2.5 dia. max.
*1. The value in the parentheses is for the E32-DC200B4.
*2. Material: Nickel-plated brass
Stainless tube
(SUS304)
E32-DC200B
E32-DC200B4
2.5
5.5 11
1.8
2,000
25
10
Two, 1-dia. optical fibers
Two, 0.5 dia.
Two hexagon clamping nuts
Two toothed washers
M3 x 0.5 sensing head
(SUS304)
Two Fiber Attachments (E39-F9)
E32-DC200E
2.5
5.5 11 90
(40) *
1.8
2,000
25
10
Two, 1-dia. optical fibers
Two, 0.5 dia.
Two hexagon clamping nuts
Two toothed washers
M3 x 0.5
sensing head (SUS304)
1.2 dia. max.
* The value in the parentheses is for the E32-DC200F4.
Stainless
tube
(SUS304)
Two Fiber Attachments (E39-F9)
E32-DC200F
E32-DC200F4
E3S-X3
22
: Indicates models that do not allow free cutting.
5.2
10 17
2.4 15
2,000
Two, 2.2-dia. optical fibers
Sixteen, 0.265 dia.
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75
sensing head
(SUS304) Protective tube
E32-D11
5.5
25
10
2.5 151.8
11 2,000
Two, 1-dia.
optical fibers
Four, 0.25 dia.
Two hexagon clamping nuts
Two toothed washers
M3 x 0.5
Sensing head * Protective tube
* Material: Nickel-plated brass
Two Fiber Attachments (E39-F9)
E32-D21
E32-DC200C
2.000 (when straight)
* Material: Nickel-plated brass
Two 1.0 dia.
Two hexagon clamping nuts
Two toothed washers
Two, 2.2-dia.
optical fibers
M6 x 0.75
sensing head*
22 dia.
E32-DC200D
E32-DC200D4 Two 1.0 dia. 2.5 dia.
max.
Stainless
tube
(SUS304)
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75 sensing head
(fine-pitch thread)*
2
Two, 2.2-dia.
optical fibers
2.000 (when straight)
*1. The value in the parentheses is for the E32-DC200D4.
*2. Material: Nickel-plated brass
*1
22 dia.
E32-DC9G
E32-DC9G4
1.2 dia. max.
Stainless tube
*
(Cannot
be bent
in this
range.)
Sleeve
* The value in the parentheses is for the E32-DC9G4.
10
25
15
35 2,000
15 12
Two, 1-dia.
optical fibers
Two, 0.25 dia.
Sensing head (SUS303)
Two Fiber Attachments (E39-F9)
0.8 dia.
3 dia. Heat-shrinkable tube
E32-D33
5.2
10 23
3 2.4
2,000
Two, 2.2-dia. optical fibers
Sixteen, 0.25-dia.
light reception fibers M6 x 0.75 sensing head*
2.5 dia.
Two hexagon clamping nuts
Two toothed washers
* Material: Nickel-plated brass
1.0-dia. light
emission
fiber
Note: The fiber for the emitter is identified by a white line.
E32-CC200
E3S-X3
23
: Indicates models that do not allow free cutting.
10
25
15
22 2,000
12
2
Sensing head (SUS303)
Note: The fiber for the emitter is identified by a white line.
2 dia. 3 dia.
Two, 1-dia.
optical fibers
Two Fiber Attachments (E39-F9)
Heat shrinkable
tube
0.5-dia.
light emission fiber
Four, 0.25-dia.
light reception fibers
E32-D32
Heat shrinkable tube
Sensing surface
Light baffle
6
dia.
Sensing head (stainless)
Two, 2.2 dia. optical fiber
E32-D14L
35
15 1215
1
0.5 1.5
2,000
10
25
45°
Heat shrinkable
tube
Sensing surface
Light baffle
2 dia.
Sensing head (SUS304) Two, 1-dia.
optical fibers
3 dia.
Two Fiber Attachments (E39-F9)
E32-D24
2,000
16
100
6-dia. sensing head Two, 2.2-dia. optical fibers
5 dia.
Fluoride resin
E32-D12F
3.1
4.9
2.4
133
17 2,000
10
Two, 2.2 dia. optical fiber
Two, 1.5 dia.
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75 sensing head*
* Material: Nickel-plated brass
Note: Resistant temperature is 150°C.
Resistant temperature is 130°C when used continuously.
E32-D51
E32-D61
Note:
Section A resists 300°C and section B (which is inserted to the Amplifier) resists 110°C. The operating
temperature of the section to be inserted (marked with *) must be within the operating temperature
range of the Amplifier.
Sleeve
5-dia. hexagon
clamping screw
SUS Flexible
tube
1.4 dia.
5 dia. 3.5 dia.
Two hexagon clamping nuts
Two toothed washers
M6 x 0.75 sensing head
(SUS303)
E3S-X3
24
: Indicates models that do not allow free cutting.
5
7
60 20 10 2,000 16.5 * 13
5
ABC
2.4 56.5 6.4
15
8
SUS303
M4×0.7
(SUS303)
Note:
Section A resists 400°C, section B resists 300°C, and section C (which is inserted to the Amplifier)
resists 110°C. The operating temperature of the section to be inserted (marked with *) must be within
the operating temperature range of the Amplifier.
Sleeve
Hexagon
clamping
screw
SUS Flexible
tube
1.0 dia. 2.5 dia.
Two hexagon clamping nuts
Two toothed washers
1.25-dia.
sensing head
1.65 dia. 2.8 dia. 5 dia.
4 dia.
E32-D73
10
25
M6×0.75
27.8
17.8
2.8 11
3
14
2,000
10
2.2
Two hexagon clamping nuts
Two toothed washers
Sensing head
(ABS)
Lens
(PMMA)
5 dia.
Two fiber attachments (E39-F9)
Two. 1-dia.
optical fibers
Silcone tube
E32-R21
(One E39-R3 Reflector is supplied
with the Sensor.)
Lens
(PMMA)
Sensing head (ABS)
Two, 2.2-dia. optical fibers
Standard length: 2 m
Two, M3 screws (provided)
Mounting bracket (provided)
E32-R16
(One E39-R1 Reflector is supplied with
the Sensor.)
2,000
20
10
6.5
5
4.8
6.5
20
4
Sensing head
(ABS)
Two, 2.2-dia. optical fibers
Two, 3.2-dia.
Sensing distance
6-dia.
Countersink
Note:
The fiber for the emitter is identified by a white line.
E32-L25
E3S-X3
25
Reflectors
Attachments (Order separately)
20
5
2,000
6.5
4.8
6.5
20
104
Sensing head (ABS)
Two, 2.2-dia. optical fibers
Two, 3.2 dia.
Sensing distance
6-dia.
countersink
Note:
The fiber for the emitter is identified by a white line.
E32-L25A
11
20
0.2
22.5
22.9
19.3
38
34.8
1.2
2.6
Two, M3
Adhesive tape
3425.4
Note: Mounting bracket is attached.
Material:
Reflective surface: Acrylic
Rear surface: ABS
Miniature Reflector
E39-R3 (Supplied with E32-R21)
34
40.3
5259.9
2.7
8
1.6
7.5
7
Material:
Reflective surface: Acrylic
Rear surface: ABS
Two, 3.5 dia.
Reflector
E39-R1 (Supplied with E32-R16)
4 dia.
8.9
M2.6 x 0.45
Effective depth: 3.8
Spot facing depth: 0.9
Note: One set includes two units.
E39-F1
Lens Unit
9.2
5.7
4 dia.
Note: One set includes two units.
M2.6
Effective depth: 3.2
Spot facing depth: 0.9
2.8 dia.
E39-F2
Side-view Unit
3
18
8.5
3.6
12
8±0.2 6.5
6.4
6.4
+0.2
0
Two, 4 dia.
20.7
Two, 3.2 dia.
Two, M3 x 3
slotted head machine screws
M3 toothed
washer
M3 x 6
angle fixing screw
E39-F2 Lens-equipped Reflective Unit
2.6
10.5±0.1 4
12.2
Two, 3.2-dia.
Sensing holes
18
13
4
2.1
5
Two, 3,2-dia.
Mounting holes
Two, M3
Fiber Unit mounting holes
(E32-TC200A)
Note:
When mounting, remove all of the accompanying
screws first and then screw the E32-TC200A into
the E39-F5 until the stopper comes into contact.
E39-F5 Side-view Reflective Unit
23
13
3
Two M2 screws for securing the fiber with
an allen screw.
6 dia. 4 dia.
Lens
(3.7 dia.) 2.1 dia.
Note: This Lens Unit is for the E32-D32.
E39-F3A Small Spot Lens Unit
E3S-X3
26
Protective Spiral Tubes (Order Separately)
Accessories
E39-F32A, -F32A5
E39-F32B, -F32B5
12
L
12
3 dia.
6 dia.
(4.6 dia.)
M3 x 0.5;
depth: 4 Head connector End cap
Note:
1. The length L is 1,000 for the E39-F32A/-F32B and 500 for the E39-F32A5/-F32B5.
2. The E39-F32B(5) consists of two E39-F32A(5)s.
E39-F32C, -F32C5
12
7 dia.
L
12
4 dia.
(5.6 dia.)
M4 x 0.7;
depth: 4 Head connector End cap
Note: The length L is 1,000 for the E39-F32C and 500 for the E39-F32C5.
E39-F32D, -F32D5
12
L
12
8.5 dia.
5 dia.
(7 dia.)
M6 x 0.75;
depth: 4 Head connector End cap
Note: The length L is 1,000 for the E39-F32D and 500 for the E39-F32D5.
845
Standard-fiber
insertion hole
24.5
Thin-fiber insertion hole
Fiber Cutter (Provided)
E39-F4
1.1 dia.
25
10 11.7
3.6 dia.
2.2 dia.
Mark indicating position of
insertion into Amplifier Unit
Note: Two per set.
Thin-fiber Attachments
E39-F9
26 12.8
Fiber:
2.2 dia.
3.8 dia. 3 dia. 2.2 dia.
Fiber: 2.2 dia.
Retention clip *2
Splice *1
Retention
clip *2
*1. Material: Polyester
*2. Material: Brass
Fiber Connector (Order Separately)
E39-F10
In the interest of product improvement, specifications are subject to change without notice.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.