SB(R)350 Connectors - up to 500 Amps The SB(R)350 is the largest connector in the series with power capabilities up to 450 amps with 4/0 AWG wire and 500 amps with a 350 mcm wire. Wires ranging from #1/0 (53.5 mm) to 350 mcm (150 mm) fit into the one piece housing available in standard PC or a chemical resistant PBT/PC blend. Silver plated wire or busbar contacts minimize electrical resistance while offering supreme durability and reliability. * Up to 350 mcm (150 mm) Wires Allows UL rated currents up to 500 amps * Chemical Resistant Housing Option Extends temperature range down to -40C, while offering enhanced UV and chemical resistance * Same Housings Used for Wire and Busbar Contacts Enables color-coded mechanically keyed wire to busbar connections | SB(R)350 ORDERING INFORMATION | SB(R)350 Standard Housings SB(R) 350 SECTION 3 The largest SB(R) housings work with wire contacts up to 350 mcm [150 mm] as well as busbar contacts. GenBottom View derless design mates with itself. Mechanical keys are color coded. NOTE: SB(R)350 Black and Blue Housings have the same keying features and can be intermated. Description Minimum Quantity ...... Yellow Orange Red Gray Blue Green Black --- Part Numbers --50 25 ... 914-BK 914 932-BK 932 913-BK 913 906-BK 906 912-BK 912 931-BK 931 2-7250G8 - [ 107.9 ] 4.25 [ 6.6 ] O 0.26 (2) PLC'S [ 69.9 ] 2.75 [ 28.6 ] [ 34.9 ] 1.38 1.13 MATERIAL ID P = Chemical Resistant SB(R)350 Chemical Resistant Housings Same features as the Standard SB(R)350 but molded in a chemical resistant PBT/ PC blend. Suitable for use to -40C. Description Minimum Quantity ...... Red Gray [ 182.6 ] 7.19 --- Part Numbers --50 25 .... P913-BK P913 P906-BK P906 Mated Length SB(R)350 Silver Plated Wire Contacts Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles. See reducing bushings in accessory section for smaller wires. Dimensions Mating -A-B-Cinches mm inches mm AWG mm Force - Loose Piece Part Numbers - inches mm Minimum Quantity .............. 200 150 50 ............................................................................. 300mcm 152 High 910-BK 910 * 0.75 19.05 0.87 22.10 3.04 77.2 4/0 107.2 High 908-BK 908 * 0.64 16.26 0.75 19.05 3.03 77.0 3/0 85 High 916-BK 916 * 0.58 14.73 0.70 17.78 3.00 76.2 2/0 67.4 High 907-BK 907 * 0.49 12.45 0.64 16.26 2.96 75.2 1/0 53.5 High 917-BK 917 * 0.44 11.18 0.51 12.95 2.91 73.9 [ 32.8 ] 1.29 MIN [ C 2.0 ] C 0.08 A B [ 20.6 ] 0.81 * Sold as pairs. 2 parts shipped for every 1 part ordered. (c) 2018 Anderson Power Products, Inc. All rights reserved. APP(R), Anderson Power Products(R), A(R), SB(R) and the APP Logo are registered trademarks of Anderson Power Products, Inc. - 82 - www.andersonpower.com All Data Subject To Change Without Notice SB(R)350 Silver Plated Busbar Contacts Use 2 busbar contacts per housing to provide a quick disconnect input or output busbar connection. Busbar contacts are for mating with wire contacts only. Part number 350BBS includes lock nuts. Locknuts must be ordered separately for B01998P1. [ 131.7 ] 5.19 # 3/8 - 16 THD B [ 17.0 ] 0.67 Mating Type Thread Force - Loose Piece Part Numbers Minimum Quantity .................. 50 10 ............. Busbar 3/8-16 High B01998P1 350BBS Lock Nut 3/8-16 H1216P9 110G73 See Busbar contact drawing on website for further detail. [ 22.3 ] 0.88 [ 2.5 ] 0.10 NOTE: Has not been tested by UL. | SB(R)350 CONNECTOR SPECIFICATIONS | Electrical Mechanical Current Rating Amperes 1 Wire to Wire (4/0 AWG) Wire to Wire (350 mcm) UL 1977 450 500 CSA Wire Size Range Wire Contacts with Bushings AWG 1/0 to 350 mcm mm 53.5 to 150 Max. Wire Insulation Diameter in. 1.100 mm 27.900 Operating Temperature Standard Chemical Resistant F -4 to 221 -40 to 221 C -20 to 105 -40 to 105 Avg. Mated Contact Resistance Milliohms 2 1/2" of 300mcm wire 0.050 Mating Cycles No Load by Plating Wire and Busbar Contacts Silver (Ag) 10,000 Hot Plug Current Rating Amperes - Wire & Busbar 250 cycles at 120V DC 100A Avg. Mating / Unmating Force 2 Pole Lbf. 30 Materials Min. Contact / Spring Retention Force lbf N 150 667 Voltage Rating AC/DC UL 1977 325 600 Dielectric Withstanding Voltage Volts AC 2,200 1 Housing Flammability Rating UL94 Glow Wire V-0 960C (GWFI) / 800C (GWIT) Wire & Busbar Contacts 4 Base Plating Copper Alloy Silver Contact Termination Methods Crimp Hand Solder Wrench / Socket Wire Contacts Wire Contacts Busbar Contacts NOTE 1: See IEC 60664-1 for working voltage. Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25C ambient temperature. UL rating not to exceed the maximum operating temperature. CSA rating below a 30C temperature rise. Limited by the thermal properties of the connector plastic housing. Use APP recommended tooling only. Alternate tools may adversely affect the performance of our connectors along with UL and CSA recognition. 4 Has not been tested by UL. | IEC INFORMATION | Connector Series Creepage/Clearance Material Configurations per IEC 60950-1 Group Unmated 5.66 mm Mated 5.66 mm IIIa SB(R)350 Attributes SB350 Protection AMP Rating AC/DC Voltage Rating AC/DC (Steady State) Breaking Capacity - AMP Rating /Cycles Voltage Rating (Breaking Capacity) Finger Safety - Mated only Wire Size tested Contact Series Tested Climatic Testing (Cold,Heat & MFG) Cycle Life Mechanical Strength Impact Temperature Range 350 500 V AC/DC (Operational) 100 Amp / 10 cycles 125 VDC IEC 60529 - IP20 120 mm 908 IEC 60512 Test -11j, 11i & 11g, IEC 60512 Test 9a - 5000 Cycles IEC 60512-5 @ 29.5 Inches - dropped 8 times -20 C to 105 C -4 F to 221 F Touch Safety with Wire Contacts IEC 60529 IP10 All Data Subject To Change Without Notice NOTE 2: Refer to the Constructional Data form for additional information on our website., www.andersonpower.com www.andersonpower.com - 83 - SECTION 3 Polycarbonate Polycarbonate / PBT blend Stainless Steel SB(R) 350 Housing Standard Plastic Resin Chem. Resistant Resin Contact Retention Spring N 133 | SB(R)350 CONNECTOR TEMPERATURE CHARTS| Temperature rise charts are based on a 25C ambient temperature. For Temperature Rise Above 60C, Consult the Extended Temperature Rise Charts in the Appropriate Product Section on the Website. Current - Temperature Derating per IEC 60512-5-2 Test 5B SB(R)350 Derating vs. Ambient Temperature SB(R)350 Temperature Rise at Constant Current 125 Ambient Temperature (C) 60 Temperature Rise Above Ambient (C) 50 40 30 20 10 0 0 50 100 150 200 250 300 350 400 450 500 350 MCM 3/0 AWG Amperes Applied 300 MCM 2/0 AWG 4/0 AWG 1/0 AWG 100 75 50 25 0 50 100 150 200 250 300 350 400 450 500 550 350 MCM 3/0 AWG Amperes Applied 300 MCM 2/0 AWG 4/0 AWG 1/0 AWG | SB(R) 350 ACCESSORIES | SB(R) 350 SECTION 3 Cable Clamps Durable metal cable clamps securely hold cables to prevent accidental strain or pulls from dislodging wire or contacts from the housing. Cable clamps are recommended for solder terminated wires. Cable Size Min / Max Min / Max Description Inches O.D. mm O.D. - Part Numbers Minimum Quantity ............................................................................... 10 ..... Bolt On for Discrete Conductor 1.00 to 0.35 25.4 to 8.8 996G1 Discrete Conductor w/ Integral Handle 0.76 to 0.32 19.3 to 8.2 911 "A" frame handle (not included). 996G1 The given wire O.D. information is an estimate. Cable clamps should be evaluated for performance with the actual wire to be used. 911 Handles Handles are made out of durable PC plastic. Hardware to attach to connector body included in kits. Description Minimum Quantity .... Gray Handle Kit Red Handle Kit Handle Only, Gray Handle Only, Red Handle Only, Black Hardware Bag ----- Part Numbers ----100 25 ... 995G2 995G4 3-5074P1 3-5074P3 3-5074P5 106G7 Handle Clamp Dust Cover Prevents dust and dirt from entering the mating interface of the connector when unmated. NOTE: Not a Hermetic Seal. Description ----- Part Numbers ----Minimum Quantity .............................. 500 50 ... Dust Cover with Lanyard Strap, Red 113890P3 134G3 (R) SB 350 Lockout - 84 - www.andersonpower.com Slide cover over mating end. All Data Subject To Change Without Notice Works with standard lockout - tagout equipment to prevent access to the mating interface of the connector. Made from durable PC plastic. Description --- Part Number --Minimum Quantity ........... 25 ..... Red Lockout - Tagout Kit SB350-LOCKOUT SB350 Connector not included. Manual Release Bracket - Mounting Side Works with the Locking Side to ease mating and unmating connectors. Description Minimum Quantity ........... Bracket and Hardware Kit Bracket Only Hardware Bag ----------- Part Numbers ---------66 25 10 ... 922G1 B00229P1 106G6 - Mounting Half (charger). Locking Half Components Cable Size Min / Max Min / Max Description Inches O.D. mm O.D. - Part Numbers Minimum Quantity ............................................................................... 10 .......... Bracket and Hardware Kit w/ Clamp Kit 0.94 to 0.61 23.7 to 15.5 919 The given wire O.D. information is an estimate. Cable clamps should be evaluated for performance with the actual wire to be used. Mounting Half Manual Release Bracket - Locking Side no Cable Clamp Works with the Battery side to ease mating and unmating connectors. Description - Part Numbers Minimum Quantity ................................... 10 ............. Bracket and Hardware Kit No Clamp Kit 919G1 Mounting Half Reducing Bushings: for Use with Contact # 907 Use with contact part number 907-BK to allow a smaller wire to be used with the connector. Electrical capability is derated with smaller wire. Contact Barrel Size Wire Size --- Part Numbers --Minimum Quantity ......................................... 500 100 ... 2/0 AWG [67.4 mm] 1/0 AWG [53.5 mm] 5918-BK 5918 [ 28.4 ] 1.12 [ 11.1 ] 0.44 Wire Entrance All Data Subject To Change Without Notice 2018-0054 DS-SB350 REV C6 www.andersonpower.com - 85 - SECTION 3 Works with the Mounting Side to ease mating and unmating connectors. SB(R) 350 Manual Release Bracket - Locking Side with Cable Clamp SB(R) - Tooling Information Wire Size AWG mm Loose Piece Part Numbers Silver Plating Loose Piece Contact Crimp Tools Pneumatic Bench Tool Hand Tool Die Locator 1388G6 1389G6 Number of Crimps SB(R)50 #6 13.3 #8 8.4 1307 5900 #10 / 12 5.3 / 3.3 5952 1309G4 Single 1387G1 5953 1388G7 1389G7 5915 SB(R)120 #1 42.4 1388G3 1323G1 #2 33.6 1319 #4 21.2 1319G4 #6 13.3 1319G6 1368 Series 1387G1 1388G4 1389G4 Single 1/0 53.5 1382 #1 42.4 1347 #2 33.6 1383 #4 21.1 1384 #6 13.3 1348 1368 Series 1387G2 1303G13 1304G32 Double 1387G1 1388G4 1389G3 Single SB(R)350 SB(R) SECTION 3 SB(R)175 300mcm 152 910 4/0 107.2 908 3/0 85 916 2/0 67.4 907 1/0 53.5 917 N/A 1368 Series 1303G3 Double 1387G2 1303G12 1304G31 NOTE: See website for the most current information. - 86 - www.andersonpower.com All Data Subject To Change Without Notice