AC-DC Power Supplies PCB Mount Type
TUH S 10 F 05
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
R
1 2 3 4 5
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL TUHS10F05 TUHS10F12 TUHS10F15 TUHS10F24
MAX OUTPUT WATTAGE[W] 10.00 10.80 10.10 10.80
DC OUTPUT 5V 2A 12V 0.9A 15V 0.67A 24V 0.45A
SPECIFICATIONS
MODEL TUHS10F05 TUHS10F12 TUHS10F15 TUHS10F24
INPUT
VOLTAGE[V] AC85 - 264 1f DC120 - 370
CURRENT[A]
ACIN 100V
0.25typ (Io=100%)
ACIN 200V
0.14typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
81typ 85typ 85typ 86typ
ACIN 200V
82typ 85typ 85typ 87typ
INRUSH CURRENT Limited by external components
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 2 0.9 0.67 0.45
LINE REGULATION[mV] 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 100max 120max 150max
RIPPLE[mVp-p]
30 to 100% Load
*1
120max 160max 160max 200max
0 to 30% Load
AC85V - 240V
*1
400max 480max 480max 580max
RIPPLE
NOISE[mVp-p]
30 to 100% Load
*1
160max 200max 200max 240max
0 to 30% Load
AC85V - 240V
*1
480max 560max 560max 660max
TEMPERATURE
REGULATION[mV]
0 to +70C
100max 180max 240max 360max
-40 to +70C
150max 270max 360max 480max
DRIFT[mV]
*
2
20max 48max 60max 96max
OUTPUT VOLTAGE SETTING[V]
4.90 - 5.30 11.40 - 12.60 14.25 - 15.75 23.00 - 25.00
PROTECTION CIRCUIT
AND OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recover automatically
OVERVOLTAGE PROTECTION[V]
5.50 - 8.00 13.20 - 19.20 16.50 - 24.00 26.40 - 38.40
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
*
3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS CASE SIZE/WEIGHT 33.0X15.0X22.0mm[1.3X0.59X0.86 inches] (WXHXD) / 25g max
COOLING METHOD Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 47μF capasitor as Cbc.
ClassⅡ