TUHS-2
TUHS3
AC-DC Power Supplies PCB Mount Type
TUH S 3 F 05
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
R
1 2 3 4 5
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL TUHS3F05 TUHS3F12 TUHS3F15 TUHS3F24
MAX OUTPUT WATTAGE[W] 3.00 3.00 3.00 3.12
DC OUTPUT 5V 0.6A 12V 0.25A 15V 0.2A 24V 0.13A
SPECIFICATIONS
MODEL TUHS3F05 TUHS3F12 TUHS3F15 TUHS3F24
INPUT
VOLTAGE[V] AC85 - 264 1f DC120 - 370
CURRENT[A]
ACIN 100V
0.08typ (Io=100%)
ACIN 200V
0.05typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
79typ 81typ 81typ 81typ
ACIN 200V
78typ 79typ 79typ 79typ
INRUSH CURRENT Limited by external components
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 0.6 0.25 0.2 0.13
LINE REGULATION[mV] 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 100max 120max 150max
RIPPLE[mVp-p]
30 to 100% Load
*1
120max 160max 160max 200max
0 to 30% Load
AC85V - 240V
*1
400max 480max 480max 580max
RIPPLE
NOISE[mVp-p]
30 to 100% Load
*1
160max 200max 200max 240max
0 to 30% Load
AC85V - 240V
*1
480max 560max 560max 660max
TEMPERATURE
REGULATION[mV]
0 to +85C
100max 180max 240max 360max
-40 to +85C
150max 270max 360max 480max
DRIFT[mV]
*
2
20max 48max 60max 96max
OUTPUT VOLTAGE SETTING[V]
4.90 - 5.30 11.40 - 12.60 14.25 - 15.75 23.00 - 25.00
PROTECTION CIRCUIT
AND OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recover automatically
OVERVOLTAGE PROTECTION[V]
5.50 - 8.00 13.20 - 19.20 16.50 - 24.00 26.40 - 38.40
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
*
3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS CASE SIZE/WEIGHT 28.7X12.7X17.5mm[1.13X0.50X0.69 inches] (WXHXD) / 15g max
COOLING METHOD Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 18μF capasitor as Cbc.
Class
TUHS-3
TUHS3
External view
(TOP VIEW)
Tolerance : ±0.5 [±0.02]
Weight : 15g max
Case material : PBT
Pin material : Copper
Plating treatment of pin : Lead free plating
Dimensions in mm, [ ]=inches
Name Plate
[0.2]
5.08
[0.95]
24.1
[0.25]
6.4
[0.51]
12.9
[0.2]
5.08
-
BC+BC
+Vout
-
Vout
AC1
AC2
1±0.1
2.3
[0.09]
12.9
6.4
17.5
24.1
5.08
2.3
[0.09]
28.7
[0.95]
[0.2]
[1.13]
12.7
0.5
7.82 5.08
[0.51]
[0.25]
[0.69]
[0.31] [0.2]
3.5
[0.5]
[0.02]
[0.14]
Div. : 0.2inch
Dimensions in : [inch]
mm
Recommending size for processing PCB
TUHS-4
TUHS5
AC-DC Power Supplies PCB Mount Type
TUH S 5 F 05
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
R
1 2 3 4 5
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL TUHS5F05 TUHS5F12 TUHS5F15 TUHS5F24
MAX OUTPUT WATTAGE[W] 5.00 5.40 5.10 5.28
DC OUTPUT 5V 1A 12V 0.45A 15V 0.34A 24V 0.22A
SPECIFICATIONS
MODEL TUHS5F05 TUHS5F12 TUHS5F15 TUHS5F24
INPUT
VOLTAGE[V] AC85 - 264 1f DC120 - 370
CURRENT[A]
ACIN 100V
0.13typ (Io=100%)
ACIN 200V
0.08yp (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
78typ 82typ 82typ 83typ
ACIN 200V
79typ 82typ 82typ 83typ
INRUSH CURRENT Limited by external components
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 1 0.45 0.34 0.22
LINE REGULATION[mV] 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 100max 120max 150max
RIPPLE[mVp-p]
30 to 100% Load
*1
120max 160max 160max 200max
0 to 30% Load
AC85V - 240V
*1
400max 480max 480max 580max
RIPPLE
NOISE[mVp-p]
30 to 100% Load
*1
160max 200max 200max 240max
0 to 30% Load
AC85V - 240V
*1
480max 560max 560max 660max
TEMPERATURE
REGULATION[mV]
0 to +80C
100max 180max 240max 360max
-40 to +80C
150max 270max 360max 480max
DRIFT[mV]
*
2
20max 48max 60max 96max
OUTPUT VOLTAGE SETTING[V]
4.90 - 5.30 11.40 - 12.60 14.25 - 15.75 23.00 - 25.00
PROTECTION CIRCUIT
AND OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recover automatically
OVERVOLTAGE PROTECTION[V]
5.50 - 8.00 13.20 - 19.20 16.50 - 24.00 26.40 - 38.40
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
*
3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS CASE SIZE/WEIGHT 28.7X12.7X17.5mm[1.13X0.50X0.69 inches] (WXHXD) / 15g max
COOLING METHOD Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 22μF capasitor as Cbc.
Class
TUHS-5
TUHS5
External view
(TOP VIEW)
Tolerance : ±0.5 [±0.02]
Weight : 15g max
Case material : PBT
Pin material : Copper
Plating treatment of pin : Lead free plating
Dimensions in mm, [ ]=inches
Name Plate
[0.2]
5.08
[0.95]
24.1
[0.25]
6.4
[0.51]
12.9
[0.2]
5.08
-
BC+BC
+Vout
-
Vout
AC1
AC2
1±0.1
2.3
[0.09]
12.9
6.4
17.5
24.1
5.08
2.3
[0.09]
28.7
[0.95]
[0.2]
[1.13]
12.7
0.5
7.82 5.08
[0.51]
[0.25]
[0.69]
[0.31] [0.2]
3.5
[0.5]
[0.02]
[0.14]
Div. : 0.2inch
Dimensions in : [inch]
mm
Recommending size for processing PCB
TUHS-6
TUHS10
AC-DC Power Supplies PCB Mount Type
TUH S 10 F 05
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
R
1 2 3 4 5
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL TUHS10F05 TUHS10F12 TUHS10F15 TUHS10F24
MAX OUTPUT WATTAGE[W] 10.00 10.80 10.10 10.80
DC OUTPUT 5V 2A 12V 0.9A 15V 0.67A 24V 0.45A
SPECIFICATIONS
MODEL TUHS10F05 TUHS10F12 TUHS10F15 TUHS10F24
INPUT
VOLTAGE[V] AC85 - 264 1f DC120 - 370
CURRENT[A]
ACIN 100V
0.25typ (Io=100%)
ACIN 200V
0.14typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
81typ 85typ 85typ 86typ
ACIN 200V
82typ 85typ 85typ 87typ
INRUSH CURRENT Limited by external components
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 2 0.9 0.67 0.45
LINE REGULATION[mV] 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 100max 120max 150max
RIPPLE[mVp-p]
30 to 100% Load
*1
120max 160max 160max 200max
0 to 30% Load
AC85V - 240V
*1
400max 480max 480max 580max
RIPPLE
NOISE[mVp-p]
30 to 100% Load
*1
160max 200max 200max 240max
0 to 30% Load
AC85V - 240V
*1
480max 560max 560max 660max
TEMPERATURE
REGULATION[mV]
0 to +70C
100max 180max 240max 360max
-40 to +70C
150max 270max 360max 480max
DRIFT[mV]
*
2
20max 48max 60max 96max
OUTPUT VOLTAGE SETTING[V]
4.90 - 5.30 11.40 - 12.60 14.25 - 15.75 23.00 - 25.00
PROTECTION CIRCUIT
AND OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recover automatically
OVERVOLTAGE PROTECTION[V]
5.50 - 8.00 13.20 - 19.20 16.50 - 24.00 26.40 - 38.40
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
*
3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS CASE SIZE/WEIGHT 33.0X15.0X22.0mm[1.3X0.59X0.86 inches] (WXHXD) / 25g max
COOLING METHOD Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 47μF capasitor as Cbc.
Class
TUHS-7
TUHS10
External view
Recommending size for processing PCB
(TOP VIEW)
Tolerance : ±0.5 [±0.02]
Weight : 25g max
Case material : PBT
Pin material : Copper
Plating treatment of pin : Lead free plating
Dimensions in mm, [ ]=inches
[0.2]
5.08 [1.1]
28
[0.25]
6.4
[0.51]
12.9
[0.67]
17
[0.3]
7.62
-
BC+BC
+Vout
-
Vout
AC1
AC2
0.5
22
15
3.5
2.5 5.08
28
33
2.5 6.4
12.9
9.38 7.62
Div. : 0.2inch
Dimensions in : [inch]
mm
Name Plate
[0.1]
[0.1]
[1.1]
[0.2]
[1.3]
[0.51]
[0.25]
[0.87]
[0.37] [0.3]
[0.59]
[0.02]
[0.14]
TUHS-8
TUHS15
AC-DC Power Supplies PCB Mount Type
TUH S 15 F 12
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
R
1 2 3 4 5
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL TUHS15F12 TUHS15F15 TUHS15F24
MAX OUTPUT WATTAGE[W] 15.00 15.00 15.12
DC OUTPUT 12V 1.25A 15V 1A 24V 0.63A
SPECIFICATIONS
MODEL TUHS15F12 TUHS15F15 TUHS15F24
INPUT
VOLTAGE[V] AC85 - 264 1f DC120 - 370
CURRENT[A]
ACIN 100V
0.35typ (Io=100%)
ACIN 200V
0.18typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
85typ 85typ 86typ
ACIN 200V
85typ 85typ 87typ
INRUSH CURRENT Limited by external components
OUTPUT
VOLTAGE[V] 12 15 24
CURRENT[A] 1.25 1 0.63
LINE REGULATION[mV] 48max 60max 96max
LOAD REGULATION[mV] 100max 120max 150max
RIPPLE[mVp-p]
30 to 100% Load
*1
160max 160max 200max
0 to 30% Load
AC85V - 240V
*1
480max 480max 580max
RIPPLE
NOISE[mVp-p]
30 to 100% Load
*1
200max 200max 240max
0 to 30% Load
AC85V - 240V
*1
560max 560max 660max
TEMPERATURE
REGULATION[mV]
0 to +50C
180max 240max 360max
-40 to +50C
270max 360max 480max
DRIFT[mV]
*
2
48max 60max 96max
OUTPUT VOLTAGE SETTING[V]
11.40 - 12.60 14.25 - 15.75 23.00 - 25.00
PROTECTION CIRCUIT
AND OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recover automatically
OVERVOLTAGE PROTECTION[V]
13.20 - 19.20 16.50 - 24.00 26.40 - 38.40
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
*
3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS CASE SIZE/WEIGHT 33.0X15.0X22.0mm[1.3X0.59X0.86 inches] (WXHXD) / 25g max
COOLING METHOD Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 68μF capasitor as Cbc.
Class
TUHS-9
TUHS15
External view
Recommending size for processing PCB
(TOP VIEW)
Tolerance : ±0.5 [±0.02]
Weight : 25g max
Case material : PBT
Pin material : Copper
Plating treatment of pin : Lead free plating
Dimensions in mm, [ ]=inches
[0.2]
5.08 [1.1]
28
[0.25]
6.4
[0.51]
12.9
[0.67]
17
[0.3]
7.62
-
BC+BC
+Vout
-
Vout
AC1
AC2
0.5
22
15
3.5
2.5 5.08
28
33
2.5 6.4
12.9
9.38 7.62
Div. : 0.2inch
Dimensions in : [inch]
mm
Name Plate
[0.1]
[0.1]
[1.1]
[0.2]
[1.3]
[0.51]
[0.25]
[0.87]
[0.37] [0.3]
[0.59]
[0.02]
[0.14]
TUHS-10
TUHS25
AC-DC Power Supplies PCB Mount Type
TUH S 25 F 05
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
R
1 2 3 4 5
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL TUHS25F05 TUHS25F12 TUHS25F15 TUHS25F24
MAX OUTPUT WATTAGE[W] 25.00 25.20 25.50 26.40
DC OUTPUT 5V 5A 12V 2.1A 15V 1.7A 24V 1.1A
SPECIFICATIONS
MODEL TUHS25F05 TUHS25F12 TUHS25F15 TUHS25F24
INPUT
VOLTAGE[V] AC85 - 264 1f DC120 - 370
CURRENT[A]
ACIN 100V
0.55typ (Io=100%)
ACIN 200V
0.35typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
87typ 88typ 88typ 89typ
ACIN 200V
87typ 88typ 88typ 90typ
INRUSH CURRENT Limited by external components
OUTPUT
VOLTAGE[V] 5 12 15 24
CURRENT[A] 5 2.1 1.7 1.1
LINE REGULATION[mV] 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 100max 120max 150max
RIPPLE[mVp-p]
30 to 100% Load
*1
120max 160max 160max 200max
0 to 30% Load
AC85V - 240V
*1
400max 480max 480max 580max
RIPPLE
NOISE[mVp-p]
30 to 100% Load
*1
160max 200max 200max 240max
0 to 30% Load
AC85V - 240V
*1
480max 560max 560max 660max
TEMPERATURE
REGULATION[mV]
0 to +50C
100max 180max 240max 360max
-40 to +50C
150max 270max 360max 480max
DRIFT[mV]
*
2
20max 48max 60max 96max
OUTPUT VOLTAGE SETTING[V]
4.90 - 5.30 11.40 - 12.60 14.25 - 15.75 23.00 - 25.00
PROTECTION CIRCUIT
AND OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recover automatically
OVERVOLTAGE PROTECTION[V]
5.50 - 8.00 13.20 - 19.20 16.50 - 24.00 26.40 - 38.40
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
*
3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS CASE SIZE/WEIGHT 36.0X16.5X25.4mm[1.42X0.65X1.0 inches] (WXHXD) / 40g max
COOLING METHOD Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 120μF capasitor as Cbc.
Class
TUHS-11
TUHS25
External view
(TOP VIEW)
Tolerance : ±0.5 [±0.02]
Weight : 40g max
Case material : PBT
Pin material : Copper
Plating treatment of pin : Lead free plating
Dimensions in mm, [ ]=inches
[0.3]
7.62 [1.2]
30.48
[0.4]
10.16
[0.8]
20.32
[0.3]
7.62
-
BC+BC
+Vout
-
Vout
AC1
AC2
10.16
0.5
3.5 16.5
7.62
25.4
30.48
36
2.54
20.32
10.16
7.62
2.76
Name Plate
[0.1]
[0.11]
[0.3]
[1.42]
[1.2]
[0.8]
[0.4]
[1.0]
[0.4] [0.3]
[0.65]
[0.02]
[0.14]
Div. : 0.2inch
Dimensions in : [inch]
mm
Recommending size for processing PCB
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Cosel:
TUHS3F24 TUHS5F24 TUHS3F12 TUHS25F24 TUHS5F12 TUHS10F24 TUHS10F12 TUHS10F05 TUHS5F05
TUHS3F05 TUHS25F12 TUHS25F05 TUHS15F24 TUHS15F12