Safety and Productivity Solutions 11
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: HIGH PRESSURE
HP
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
HP Series
HE Series
4500 psi),
High
Pressure
Switch
EDPM O-ring option only available
from 100 psi to 250 psi.
F
Port Type
6,89 bar to 310,26 bar
[100 psi to 4500 psi]
Pressure
Set Point
05500
D
C
NSPST-NO,
silver contacts
SPST-NC,
silver contacts
SPDT-NO/NC,
silver contacts
Output
S
Cold-rolled
steel
Base
S
P
NPetroleum-based
hydraulic fluid
(Nitrile)
Glycol-based
fluid (EPDM)
Actuation/
Application
A
B
Standard
switch
With 3 shrink
sleeve
Options
A
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
CA
DA
BA
AA 1/4 in Spade
Terminals*
Screw
Terminals*
Deutsch DT04-3P-E005
(3-Pin Connector)*
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)*
FA
GA
EA 10-inch Cable, 18 AWG
(Wire Out, No Connector)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
HA
JA
AA
Connector
Type
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as 01545.
This allows for 2 decimal
places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
K
J
HNO, gold
inlay contacts
NC, gold
inlay contacts
SPDT(NO/NC),
gold inlay
contacts
NA
PA
RA
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
UA
VA
TA
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
YA
WA 4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)
ZA
CB
6-inch Cable w/ AMP Super
Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB
GB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
F
G
304,8 mm [12 in]
total wire length
With conduit
sleeve
H
With Vibra seal for
port threads
Packaging
Options
01
01 Individually
boxed units*
02
15 25 individual
boxes packed in
bulk packaging*
Individually
boxed units**
16 25 individual
boxes packed in
bulk packaging**
20 50 individual
boxes packed in
bulk packaging*
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
21
25 25 units in
bulk packaging*
50 individual
boxes packed in
bulk packaging**
26 25 units in
bulk packaging**
50 50 individual
parts in
bulk packaging*
* Not applicable for HP
Series (Base Style B)
** Not applicable for
HP (Base Style A) & HE Series
XA 10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000027 (18 AWG)
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)
NOTE:
Set point below 100 psi
is available only with
HP Series (Body Style B).
C1/2-20 UNF
E
FM14 x 1.5
M12 x 1.5
G9/16-18 UNF
KM18 x 1.5
M7/16-20 UNF
A1/4-18 NPT
B1/8-27 NPT
N7/8-14 UNF
TM10 x 1.0
H3/4-16 UNF
F
ENO, with 510 Ω/
0.5 W & 160 Ω/
0.5 W resistors
NC, with 3000 Ω/
0.125 W resistor J#8-32 screw with
external tooth
lockwasher***
K
L
914,4 mm [36 in]
total wire length
304,8 mm [12 in]
total wire length with
acrylic sleeve
M
914,4 mm [36 in]
total wire length with
acrylic sleeve
*** For screw terminal option
only
For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, non-adjustable set point, 550 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTNO silver contacts output, cold-rolled steel base, glycol-based
fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units.
HP Series Port Types
Thread Type Base Style A Base Style B
A = 1/418 NPT n/a 100 psi to 4500 psi
B = 1/827 NPT n/a 100 psi to 4500 psi
C = 1/220 UNF >975 psi n/a
E = M12 x 1.5 n/a 100 psi to 4500 psi
F = M14 x 1.5 >350 psi n/a
G = 9/1618 UNF >350 psi <350 psi
H = 3/416 UNF >150 psi <150 psi
K = M18 x 1.5 150 psi to 4500 psi n/a
M = 7/1620 UNF n/a 100 psi to 4500 psi
N = 7/814 UNF 150 psi to 4500 psi n/a
T = M10 x 1.0 n/a 100 psi to 4500 psi
Port Type A, B, E, M, and T will be available only with HP Series.
Base Style B will be available only with HP Series