Datasheet
Honeywell Pressure Switches
HP, HE, MH, ME, LP, LE, 5000, and 1000 Series
DESCRIPTION
The Honeywell Pressure Switch portfolio consists of:
High Pressure (HE/HP Series)
Medium Pressure (ME/MH Series)
Low Pressure (LE/LP Series)
5000 Series, 1000 Series
These pressure switches are durable, reliable
electromechanical gauge pressure on/off switches that are
available with either single pole single throw (SPST) normally
open or normally closed circuitry, or single pole double throw
(SPDT) circuitry. Their high proof pressure and burst pressure
ratings can allow for use in many rugged applications that
require the making or breaking of an electrical connection in
response to a pressure change of the system media.
DIFFERENTIATION
Through optional smart diagnostic technology,
Honeywell pressure switches are able to detect failures
such as open circuits, cut wires, worn insulation, and
more6
Optional smart diagnostic technology allows up to four
segregated signal amplitudes to perform diagnostics and
status6
Pressure port snubber suppresses pressure spikes2
IP67 sealing provides enhanced durability in harsh
environmental and washing applications1
VALUE TO CUSTOMERS
Designed to provide resistance to corrosion and enhances
equipment life with available two million life cycle rating and
IP67 rating1
Can expedite design and product cycle due to ability to
receive samples in two weeks and production units in four
weeks
Can reduce tooling, service, and manufacturing labor costs
due to standard connections, extended product life, and
expedited design and production cycle
FEATURES
Pressure switching set point range: 3.5 psi to 4500 psi
Proof pressure: from 500 psi up to 10,000 psi
Burst pressure: from 1250 psi up to 20,000 psi
Life cycle rating up to 2 million
IP67 sealing rating4
Operating temperature: 40 °C to 120 °C [40 °F to 248 °F]
Hysteresis option5
More than 15 pressure port options and over 30 electrical
terminations
Plated steel, brass or stainless steel options3
Switching point accuracy up to ±2 %
POTENTIAL APPLICATIONS
• Agricultural machinery
• Heavy duty construction
machinery and trucks
• Lawn & garden machinery
• Marine vessels
• Material handling
machinery
• Railway
• CNC machines
• Compressors/boilers
• Fracking equipment
• Food & beverage equipment
• Generators
• HVAC/R equipment
• Mud pumps
• Pneumatic equipment
• Presses/punches
• Pressure washers
• Trash compactors
• Water pumps & jet cutting
machines
PORTFOLIO
Honeywell also offers the PBN1 Series and PBN3 Series
Pressure Sensor.
1 HP, HE, MH, ME, LP, LE Series
2 HP, HE Series
3 ME, MH, LP, LE Series
4 HP, HE, LP, LE, ME Series
5 HP, HE, LP Series
6 HP, HE, ME, LP, LE Series
Safety and Productivity Solutions
50094081
Issue 5
2 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Table 1. Specifications
Character-
istic HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series
Product
length (various
terminations)
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 see page 10
Product length
(blade) see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 58,42 mm
[2.3 in]
65,6 mm
[2.583 in]
Product length
(#832 screws)
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 60,96 mm
[2.4 in]
Product length
(Metripack)
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 73,66 mm
[2.9 in]
Hex size 27 mm 27 mm 27 mm 27 mm 27 mm 27 mm 0.50 in (steel)
0.437 in (brass)
M10 x 1.25 banjo
fitting
Ease of
installation box spanner box spanner box spanner box spanner box spanner box spanner 1/2 in open spanner 18 mm open
spanner
Snap-action
switch yes yes no no yes no no no
Set point1
range 100 psi to 4500 psi 150 psi to 4500 psi 25 psi to 350 psi 40 psi to 500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi 75 psi to 150 psi 10 psi to 60 psi
[0,69 bar to 2,7 bar]
Set point
ranges
6 (Base Style A)
7 (Base Style B) 644448
Set point
accuracy
@ 25 °C
(before test)
100 psi to 150 psi
(±10 %);
150 psi to 500 psi
(±6 %);
501 psi to 4000 psi
(±3.5 %);
4000 psi to 4500
psi
(±2 %)
150 psi to 1000 psi
(±14%);
1000 psi to
2000 psi
(±12 %);
2000 psi to
4000 psi
(±11 %);
>4000 psi (±10 %)
25 psi to 50 psi
(±3 psi);
>50 psi to 100 psi
(±7 psi);
>100 psi to 150 psi
(±10 psi);
>150 psi to 250 psi
(±13 psi);
>250 psi to 350 psi
(±16 psi)
40 psi to 70 psi
(±7 psi);
>70 psi to 130 psi
(±10 psi);
>130 psi to 200 psi
(±15 psi);
>200 psi to 280 psi
(±20 psi);
>280 psi to 350 psi
(±30 psi);
>350 psi to 500 psi
(±40 psi)
3.5 psi to 10 psi (±1 psi);
>10 psi to 50 psi (±3 psi);
>50 psi to 100 psi (±7 psi);
>100 psi to 150 psi (±10 psi)
0.5 psi to 1 psi
(±0.3 psi);
1.1 psi to 3 psi
(±0.5 psi);
3.1 psi to 7 psi
(±1 psi);
8 psi to 13 psi
(±2 psi);
14 psi to 24 psi
(±3 psi);
25 psi to 50 psi
(±5 psi);
51 psi to 90 psi
(±7 psi);
91 psi to 150 psi
(±10 psi)
20 psi ±10 psi;
58 psi ±20 psi
Average dead-
band max. n/a n/a
25 psi to 50 psi
(20 psi);
>50 psi to 100 psi
(30 psi);
>100 psi to 150 psi
(40 psi);
>150 psi to 250 psi
(50 psi);
>250 psi to 350 psi
(60 psi)
40 psi to 70 psi
(±6 psi);
>70 psi to 130 psi
(±10 psi);
>130 psi to 200 psi
(±15 psi);
>200 psi to 280 psi
(±20 psi);
>280 psi to 350 psi
(±30 psi);
>350 psi to 500 psi
(±40 psi)
n/a
3.5 psi to 10 psi
(±2.8 psi);
>10 psi to 50 psi
(±14 psi);
>50 psi to 100 psi
(±38 psi);
>100 psi to 150 psi
(±40 psi)
0.5 psi to 3 psi
(±1.5 psi);
4 psi to 7 psi
(±2.5 psi);
8 psi to 13 psi
(±3.5 psi);
14 psi to 24 psi
(±8 psi);
25 psi to 50 psi
(±15 psi);
51 psi to 90 psi
(±23 psi);
91 psi to 150 psi
(±40 psi)
n/a
Operating
pressure25,000 psi max. 5,000 psi max. 500 psi max. 600 psi max. 250 psi max. 250 psi max. 150 psi, 250 psi 1400 psi
[96,5 bar] max.
Proof pressure3
10,000 psi (Base
Style A)
6,500 psi (Base
Style B)
10,000 psi 4,000 psi 6,000 psi 500 psi 500 psi 500 psi 2973 psi
[205 bar]
Hysteresis
5 % to 55 %
(based on set point
range)
3 % to 65 %
(based on set point
range)
n/a n/a
5 % to 55 %
(based on set point
range)
n/a n/a n/a
Burst pressure4
20,000 psi (Base
Style A); 9,000 psi
(Base Style B)
20,000 psi 8,000 psi 9,000 psi 1250 psi 1250 psi 4000 psi 3500 psi
[241 bar]
Current rating
(resistive)
5 A at 250 Vac
5 A at 24 Vdc
3 A at 250 Vac
3 A at 24 Vdc
7.5 mA to 3 A,
24 Vdc and 250 Vac 100 mA to 3 A max. 7.5 mA to 5 A,
24 Vdc and 250 Vac
7.5 mA to 3 A,
24 Vdc and 250 Vac
15 A, 6 Vdc;
8 A, 12 Vdc;
4 A, 24 Vdc
12 Vdc with two-
1157 bulbs (4.4 A)
Current rating
(inductive)
5 A at 115 Vac (SX
rating); 3 A at 28 Vdc n/a n/a n/a 1 A at 28 Vdc n/a 1 A, 120 Vac
0.5 A, 240 Vac n/a
8Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.
Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.
Port Styles A, B, E, M, P, T, and Y will use Base Style B.
Switches less than 150 psi will only use Base Style B.
Safety and Productivity Solutions 3
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Character-
istic HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series
Rated thermal
current 5 A 3 A 3 A n/a 5 A 3 A n/a n/a
Rated insula-
tion voltage 28 V 28 V 28 V n/a 28 V 28 V n/a n/a
Short-circuit
protective
device c-type
max. rating
Class J fuse (10 A, 600 V) n/a Class J fuse (10 A, 600 V) n/a n/a
Conditional
short circuit
current
1000 A n/a 1000 A 1000 A n/a n/a
Pollution
degree 3 (macro environment) n/a 3 (macro environment) n/a n/a
Temperature
rating
40 °C to 120 °C
[40 °F to 248 °F]
40 °C to 85 °C
[40 °F to 185 °F] 40 °C to 120 °C [40 °F to 248 °F] 40 °C to 121 °C
[40 °F to 250 °F]
20 °C to 74 °C
[4 °F to 165 °F]
Media
connection
multiple ports
available
multiple ports
available multiple ports available 1/827 NPT male
thread
multiple ports
available
Pressure ports
Refer to product
nomenclature for
pressure port types.
C = 1/220 UNF
F = M14 × 1.5
G =9/1618 UNF
H = 3/416 UNF
K = M18 × 1.5
N = 7/814 UNF
A = 1/418 NPT
B = 1/827 NPT
C = 1/220 UNF
D = 1/827 PTF
E = M12 × 1.5
F = M14 × 1.5
G = 9/1618 UNF
H = 3/416 UNF
J = G1/8 BSPP
M = 7/1620 UNF
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
A = 1/418 NPT
B = 1/827 NPT
C = 1/220 UNF
D = 1/827 PTF
E = M12 × 1.5
F = M14 × 1.5
G = 9/1618 UNF
H = 3/416 UNF
J = G1/8 BSPP
L = 3/824 UNF
M = 7/1620 UNF
P = 1/214 NPT
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
A = 1/418 NPT
B = 1/827 NPT
C = 1/220 UNF
D = 1/827 PTF
E = M12 × 1.5
F = M14 × 1.5
G = 9/1618 UNF
H = 3/416 UNF
J = G1/8 BSPP
M = 7/1620 UNF
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
A = 1/418 NPT
B = 1/827 NPT
C = 1/220 UNF
D = 1/827 PTF
E = M12 × 1.5
F = M14 × 1.5
G = 9/1618 UNF
H = 3/416 UNF
J = G1/8 BSPP
M = 7/1620 UNF
R = R1/8 BSPT
T = M10 × 1.0
V = R1/2 BSPT
Y = G1/4 BSPP
Z = R1/4 BSPT
1/827 NPT
M10 x 1.25 double
banjo;
M10 x 1;
1/827 NPT
Circuit forms5SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPST - NO/NC SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPSTNO; SPSTNC SPNO
Smart pressure single- or dual-resistor topology available single- or dual-resistor topology available
Life 2 million (Base A)
1 million (Base B) 1 million 1 million 1 million 2 million 1 million 100,000 cycles 100,000 cycles
Agency approv-
als (special use
switches)
––––––UL Custom
(select models)
Agency approv-
als (other) CE CE CE CE CE CE
Field
adjustability6no no yes yes yes yes yes no
Spike
dampening yes yes no no no no no no
Ingress
protection7
IP67 (connecetors)
IP67 (wire/Base A)
IP69K (wire/Base B)
IP00 (blade/screw)
IP67 (connectors)
IP00 (blade/screw)
IP67 (connectors)
IP67 (wire out)
IP00 (blade/screw)
IP67 (connectors)
IP00 (blade/screw)
IP67 (connectors)
IP67 (wire out)
IP00 (blade/screw)
IP67 (connectors)
IP67 (wire out)
IP00 (blade/screw)
IP00 IP65
Vibration
resistance
swept sine: 10 Hz to 2000 Hz at 15 g, 20 min/sweep; 8 hours in each axis
random: 5 Hz to 2000 Hz, 8 hours/axis; 14,88 gRMS, each axis
Shock
resistance 500 m/sec2, 11 mSEC, 100 shocks / axis 500 m/sec2, 11 mSEC 15 G @ 5 mSEC
Wetted part
(diaphragm) n/a Kapton®
(Teflon® coated) Nitrile/EPDM/LTNB Kapton®
(Teflon® coated) Tefzel®Polymide film EPDM
Wetted part
(piston) nitrile o-ring, steel piston nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring
nitrile or EPDM
o-ring EPDM
Weight 133 g [4.7 oz] (Base Style A)
178 g [6.28 oz] (Base Style B) 53 g [1.9 oz] 53 g [1.9 oz] 58 g [2.0 oz] 53 g [1.9 oz] 65 g [2.3 oz] 40 g [1.4 oz]
Contacts silver / gold inlay silver gold plated gold plated gold plated gold plated silver-plated copper silver-plated copper
Product finish zinc plating zinc plating zinc plating zinc plating zinc plating zinc plating
glass reinforced
polyester (housing);
plated steel (base)
Rynite 545 glass
filled (housing);
Travalent plated steel
(base)
1Set point: Point at which switch actuates or de-actuates
2Operating pressure: Maximum normal system operating pressure
3Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable.
4Burst pressure: Point of complete switch failure
5SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed.
6Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations.
7IP00 for AA and BA terminations.
4 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Table 2. Terminations
Series Available Terminations
HP, HE, ME,
LP, LE
AA = Spade Terminals
BA = Screw Terminals
CA = Deutsch DT043PE005 (3Pin Connector)
DA = Amp Super Seal 1.5 - 2821051 (3Pin Connector)
EA = 10-inch Cable, 18 AWG (Wire Out, No Connector)
FA = 10-inch Cable w/Deutsch DT043PE005 (3Pin Connector) (16 AWG)*
GA = 10-inch Cable w/Amp Super Seal 1.5 - 2821051 (3Pin Connector) (18 AWG)*
HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2Pin Connector) (18 AWG)*
JA = 10-inch Cable w/Din43650C (3Pin Connector) (18 AWG)*
KA = 10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3Pin Connector) (18 AWG)*
LA = 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3Pin Connector) (18 AWG)*
MA = 10-inch Cable w/Deutsch DT042PE005 (2Pin Connector) (18 AWG)
NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2Pin Connector) (18 AWG)
PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2Pin Connector) (18 AWG)
RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2Pin Connector) (16 AWG)
SA = 5.5-inch Cable w/ITT Cannon 2P SureSeal Circular Connector - SS2R1201804000 (2Pin Connector) (18 AWG)
TA = 8.5-inch Cable w/ITT Cannon 3P SureSeal Circular Connector - SS3R1208551001 (3Pin Connector) (16 AWG)*
UA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT063SEP06 (3Socket Connector) (16 AWG)*
VA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT043PE005 (3Pin Connector) (16 AWG)*
WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*
XA = 10-inch Cable w/ Metripack 2Pin Shroud Connector 153000027 (18 AWG)
YA = 6-inch Cable w/Amp Super Seal 1.5 - 2821041 (2Pin Connector) (18 AWG)*
ZA = 10-inch Cable w/Deutsch DT062SCE06 (2Socket Connector) (18 AWG)
AB = Deutsch DT042PE005 (2Pin Connector)
BB = 10-inch Cable w/Metripack 150 Delphi 12129615 (3Pin Connector) (18 AWG)*
CB = 6-inch Cable w/ AMP Super Seal 1.5 - 2820801 (2Pin Connector) (18 AWG)
DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 19674021 (18 AWG)*
EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2Pin Connector) (18 AWG)
FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2Pin Connector) (18 AWG)
GB = 8.5-inch Cable w/Deutsch Plug HD 163 96S (3Pin Connector) (16 AWG)
MH
AA = Spade Terminals
BA = Screw Terminals
DA = Amp Super Seal 1.5 - 2821051 (3Pin Connector)
EA = 10-inch Cable, 18 AWG (Wire Out, No Connector)
HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2Pin Connector) (18 AWG)*
MA = 10-inch Cable w/Deutsch DT042PE005 (2Pin Connector) (18 AWG)
NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2Pin Connector) (18 AWG)
PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2Pin Connector) (18 AWG)
RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2Pin Connector) (16 AWG)
SA = 5.5-inch Cable w/ITT Cannon 2P SureSeal Circular Connector - SS2R1201804000 (2Pin Connector) (18 AWG)
WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*
XA = 10-inch Cable w/ Metripack 2Pin Shroud Connector 153000027 (18 AWG)
YA = 6-inch Cable w/Amp Super Seal 1.5 - 2821041 (2Pin Connector) (18 AWG)*
ZA = 10-inch Cable w/Deutsch DT062SCE06 (2Socket Connector) (18 AWG)
AB = Deutsch DT042PE005 (2Pin Connector)
CB = 6-inch Cable w/ AMP Super Seal 1.5 - 2820801 (2Pin Connector) (18 AWG)
DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 19674021 (18 AWG)*
EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2Pin Connector) (18 AWG)
FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2Pin Connector) (18 AWG)
*These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suit-
able connections. Refer to wiring diagram.
Safety and Productivity Solutions 5
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS  HIGH PRESSURE: HP SERIES (BASE STYLE A), HE SERIES
Base Style A key specifications • Life: 2 million (HP), 1 million (HE); Burst pressure: 20,000 psi
Figure 1. AMP Superseal 1.5
(top view)
(bottom view)
61,64 mm
[2.427 in]
27 mm
[1.063] hex A/F
20,02 mm
[0.788 in]
Female Connector Part Number (included): C282105
Male Mating Connector (customer provided): C282087
IP Rating: IP67
Figure 2. Deutsch
(top view)
61,64 mm
[2.427 in]
27 mm
[1.063] hex A/F
(bottom view)
21,16 mm
[0.833 in]
Female Connector Part Number (included): DT043P
Male Mating Connector (customer provided): DT063S
IP Rating: IP67
Figure 3. Spade Terminal
Figure 4. Screw Terminal
(top view)
61,64 mm
[2.427 in]
27 mm
[1.063] hex A/F
(bottom view)
14,43 mm
[0.568 in]
(top view)
61,64 mm
[2.427 in]
27 mm
[1.063] hex A/F
(bottom vie
w)
12,65 mm
[0.498 in]
Figure 5. Cable
(top view)
61,64 mm
[2.427 in]
27 mm
[1.063] hex A/F
(bottom view)
19,51 mm
[0.768 in]
IP Rating: IP67
6 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS  HIGH PRESSURE: HP SERIES (BASE STYLE B)
Base Style B key specifications • Life: 1 million; Burst pressure: 9,000 psi
Nomenclature Code Thread Height “A” Diameter “ØD” Diameter “ØC” Height “H”
M7/1620 UNF
9,25 mm
[0.364 in] 11 mm [0.433 in]
C11/220 UNF
10,85 mm
[0.427 in] 11 mm [0.433 in]
G29/1618 UNF
12,24 mm
[0.482 in]
12 mm
[0.472 in]
H3/416 UNF 16,74 mm [0.66 in] 14 mm [0.551 in]
N7/814 UNF 19,6 mm [0.773 in] 16 mm [0.630 in]
TM10 x 1.0 1,60 mm [0.063 in] 9,25 mm [0.364 in] 13,79 mm [0.543 in] 11 mm [0.433 in]
EM12 x 1.5 2,48 mm [0.098 in]
10,85 mm
[0.427 in] 16,79 mm [0.661 in] 11 mm [0.433 in]
F2M14 x 1.5 2,48 mm [0.098 in]
12,24 mm
[0.482 in] 18,8 mm [0.74 in]
12 mm
[0.472 in]
KM18 x 1.5 2,48 mm [0.098 in] 16,74 mm [0.66 in] 23,8 mm [0.937 in] 14 mm [0.551 in]
B1/827 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]
A1/418 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]
1Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.
2Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.
Switches less than 150 psi will use only Base Style B.
Figure 7. HP Series Pressure Port Dimensions
Table 3. HP/HE Series Pressure Port Diameters and Heights
“Ø D”
“H”
Thread
“Ø D”
“H”
Thread
“Ø D”
“H”
Thread
“Ø C”
“A
Figure 6. HP Series Base Style B
[2.814 in]
(bottom view)
HP with smaller port: dimension 2.814 in remains same
14,43 mm
[0.568 in]
Safety and Productivity Solutions 7
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS  MEDIUM PRESSURE: MH SERIES
Port Diameter “ØD” Height “H”
R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]
R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]
R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]
1/827 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]
1/418 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]
1/827 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]
G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]
G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]
3/416 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in]
7/1620 UNF
9,25 mm
[0.364 in] 9,09 mm [0.358 in]
9/1618 UNF
12,24 mm
[0.482 in] 10,00 mm[0.394 in]
1/220 UNF
10,85 mm
[0.427 in] 9,09 mm [0.358 in]
Port Height
“A”
Diameter
“ØC
Diameter
“ØD” Height “H”
M14 × 1.5 2,49 mm
[0.098 in]
18,8 mm
[0.74 in]
11,71 mm
[0.461 in]
10,998 mm
[0.433 in]
M12 × 1.5 2,49 mm
[0.098 in]
16,79 mm
[0.661 in]
9,70 mm
[0.382 in]
10,998 mm
[0.433 in]
M10 × 1.0 1,6 mm
[0.063 in]
13,79 mm
[0.543 in]
8,41 mm
[0.331 in]
8,51 mm
[0.335 in]
Figure 13. MH Series Pressure Port Dimensions
Table 4. MH Series Pressure Port Diameters and Heights
Figure 8. AMP Superseal 1.5
Figure 9. Deutsch 2-pin
Figure 10. Wire out
Figure 11. Blade terminal
(bot
tom view) 50,29 mm max.
[1.98 in] max.
Figure 12. Screw terminal
(bot
tom view) 67,06 mm max.
[2.64 in] max.
(bottom view)
67,06 mm max.
[2.64 in] max.
(bottom view) 38,35 mm max.
[1.51 in] max.
(bottom view) 38,35 mm max.
[1.51 in] max.
“A
8 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS  MEDIUM PRESSURE: ME SERIES
Port Diameter “ØD” Height “H”
R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]
R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]
R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]
1/827 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]
1/418 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]
1/827 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]
G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]
G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]
3/416 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in]
7/1620 UNF
9,25 mm
[0.364 in] 9,09 mm [0.358 in]
9/1618 UNF
12,24 mm
[0.482 in] 10,00 mm[0.394 in]
1/220 UNF
10,85 mm
[0.427 in] 9,09 mm [0.358 in]
Port Height
“A”
Diameter
“ØC
Diameter
“ØD” Height “H”
M14 × 1.5 2,49 mm
[0.098 in]
18,8 mm
[0.74 in]
11,71 mm
[0.461 in]
10,998 mm
[0.433 in]
M12 × 1.5 2,49 mm
[0.098 in]
16,79 mm
[0.661 in]
9,70 mm
[0.382 in]
10,998 mm
[0.433 in]
M10 × 1.0 1,6 mm
[0.063 in]
13,79 mm
[0.543 in]
8,41 mm
[0.331 in]
8,51 mm
[0.335 in]
Figure 20. ME Series Pressure Port Dimensions
HH
H
ØD
ØD
ØD
ØC
A
Table 5. ME Series Pressure Port Diameters and Heights
Figure 14. AMP Superseal 1.5
(bot
tom view) 65,3 mm max.
[2.57 in] max.
F
emale connector part number (included): C-282105
Male mating connector (customer provided):
C-282087
IP rating: IP67
Figure 15. Deutsch 3-pin
(bot
tom view)
64 mm max.
[2.52 in] max.
Female connector part number (included): DT04-3P
Male mating connector (customer provided): DT06-3S
IP rating: IP67
Figure 16. Deutsch 2-pin
Figure 17. Wire out
(bot
tom view) 65,5 mm max.
[2.58 in] max.
F
emale connector part number (included): DT04-2P
Male mating connector (customer provided):
DT06-2S
IP rating:
IP67
(bot
tom view) 48,51 mm max.
[1.91 in] max.
IP rating:
IP67
Figure 18. Blade terminal
Figure 19. Screw terminal
(bot
tom view) 38,9 mm max.
[1.57 in] max.
(bot
tom view) 38,9 mm max.
[1.57 in] max.
Safety and Productivity Solutions 9
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS  LOW PRESSURE: LP SERIES, LE SERIES
Port Diameter “ØD” Height “H”
R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in]
R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in]
R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in]
1/827 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in]
1/418 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in]
1/827 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in]
G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in]
G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in]
3/416 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in]
7/1620 UNF
9,25 mm
[0.364 in] 9,09 mm [0.358 in]
9/1618 UNF
12,24 mm
[0.482 in] 10,00 mm [0.394 in]
1/220 UNF
10,85 mm
[0.427 in] 9,09 mm [0.358 in]
Port Height
“A”
Diameter
“ØC
Diameter
“ØD” Height “H”
M14 × 1.5 2,49 mm
[0.098 in]
18,8 mm
[0.74 in]
11,71 mm
[0.461 in]
10,998 mm
[0.433 in]
M12 × 1.5 2,49 mm
[0.098 in]
16,79 mm
[0.661 in]
9,70 mm
[0.382 in]
10,998 mm
[0.433 in]
M10 × 1.0 1,6 mm
[0.063 in]
13,79 mm
[0.543 in]
8,41 mm
[0.331 in]
8,51 mm
[0.335 in]
Figure 21. AMP Superseal 1.5
(bot
tom view) 58,93 mm max.
[2.32 in] max.
Figure 22. Deutsch 3-pin
(bot
tom view) 57,66 mm max.
[2.27 in] max.
Figure 23. Deutsch 2-pin
Figure 24. Wire out
(bot
tom view) 58,93 mm max.
[2.32 in] max.
(bot
tom view) 42,16 mm max.
[1.66 in] max.
IP rating:
IP67
Figure 25. Spade terminal
Figure 26. Screw terminal
(bot
tom view) 33,02 mm max.
[1.30 in] max.
(bot
tom view) 33,02 mm max.
[1.30 in] max.
Figure 27. LP/LE Series Pressure Port Dimensions
HH
H
ØD
ØD
ØD
ØC
A
Table 6. LP/LE Series Pressure Port Diameters and Heights
10 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
DIMENSIONS  1000 SERIES, 5000 SERIES
Figure 28. 1000 Series Dimensions
6,02 mm
[0.237 in]
12,4 mm
[0.488 in]
65,6 mm
[2.583 in]
31,5 mm
[1.24 in]
33,1 mm
[1.303 in]
11,18 mm [0.44 in] min.
last full thread ref.
45°
M 10 x 1.25 -6G
5,5 mm
[0.22 in]
55,11 mm
[2.17 in]
45°
34,85 mm
[1.37 in]
3,2 mm
[0.13 in]
2,1 mm
[0.08 in]
1,5 x 45°
8,99 mm
[0.35 in]
2X 9,91 mm
[0.39 in]
Ø2,5 cross drill
0.25 x 45° chamfer
Figure 29. 5000 Series Dimensions
8-32 x 1/4 screw (3)
Ø 37,34 m
m
[Ø 1.47 in]
ref.
58,42 mm
[2.3 in] ref.
1/8-27 NPT
0.500 hex ref
.
Safety and Productivity Solutions 11
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: HIGH PRESSURE
HP
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
HP Series
HE Series
(100 psi to
4500 psi),
High
Pressure
Switch
EDPM O-ring option only available
from 100 psi to 250 psi.
F
Port Type
6,89 bar to 310,26 bar
[100 psi to 4500 psi]
Pressure
Set Point
05500
D
C
NSPST-NO,
silver contacts
SPST-NC,
silver contacts
SPDT-NO/NC,
silver contacts
N
Output
S
Cold-rolled
steel
Base
S
P
NPetroleum-based
hydraulic fluid
(Nitrile)
Glycol-based
fluid (EPDM)
P
Actuation/
Application
A
B
Standard
switch
With 3 shrink
sleeve
Options
A
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
CA
DA
BA
AA 1/4 in Spade
Terminals*
Screw
Terminals*
Deutsch DT04-3P-E005
(3-Pin Connector)*
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)*
FA
GA
EA 10-inch Cable, 18 AWG
(Wire Out, No Connector)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
HA
JA
AA
Connector
Type
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as 01545.
This allows for 2 decimal
places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
K
J
HNO, gold
inlay contacts
NC, gold
inlay contacts
SPDT(NO/NC),
gold inlay
contacts
NA
PA
RA
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
UA
VA
TA
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
YA
WA 4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)
ZA
CB
6-inch Cable w/ AMP Super
Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB
GB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)*
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
F
G
304,8 mm [12 in]
total wire length
With conduit
sleeve
H
With Vibra seal for
port threads
Packaging
Options
01
01 Individually
boxed units*
02
15 25 individual
boxes packed in
bulk packaging*
Individually
boxed units**
16 25 individual
boxes packed in
bulk packaging**
20 50 individual
boxes packed in
bulk packaging*
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
21
25 25 units in
bulk packaging*
50 individual
boxes packed in
bulk packaging**
26 25 units in
bulk packaging**
50 50 individual
parts in
bulk packaging*
* Not applicable for HP
Series (Base Style B)
** Not applicable for
HP (Base Style A) & HE Series
XA 10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000027 (18 AWG)
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)
NOTE:
Set point below 100 psi
is available only with
HP Series (Body Style B).
C1/2-20 UNF
E
FM14 x 1.5
M12 x 1.5
G9/16-18 UNF
KM18 x 1.5
M7/16-20 UNF
A1/4-18 NPT
B1/8-27 NPT
N7/8-14 UNF
TM10 x 1.0
H3/4-16 UNF
F
ENO, with 510 /
0.5 W & 160 /
0.5 W resistors
NC, with 3000 /
0.125 W resistor J#8-32 screw with
external tooth
lockwasher***
K
L
914,4 mm [36 in]
total wire length
304,8 mm [12 in]
total wire length with
acrylic sleeve
M
914,4 mm [36 in]
total wire length with
acrylic sleeve
*** For screw terminal option
only
For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, non-adjustable set point, 550 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTNO silver contacts output, cold-rolled steel base, glycol-based
fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units.
HP Series Port Types
Thread Type Base Style A Base Style B
A = 1/418 NPT n/a 100 psi to 4500 psi
B = 1/827 NPT n/a 100 psi to 4500 psi
C = 1/220 UNF >975 psi n/a
E = M12 x 1.5 n/a 100 psi to 4500 psi
F = M14 x 1.5 >350 psi n/a
G = 9/1618 UNF >350 psi <350 psi
H = 3/416 UNF >150 psi <150 psi
K = M18 x 1.5 150 psi to 4500 psi n/a
M = 7/1620 UNF n/a 100 psi to 4500 psi
N = 7/814 UNF 150 psi to 4500 psi n/a
T = M10 x 1.0 n/a 100 psi to 4500 psi
Port Type A, B, E, M, and T will be available only with HP Series.
Base Style B will be available only with HP Series
12 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: MEDIUM PRESSURE, HIGH BURST
MH
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
MH Series
Medium
Pressure
Switch
C1/2-20 UNF
E
FM14 x 1.5
M12 x 1.5
G
A
Port Type
0,24 bar to 10,34 bar
[3.5 psi to 150 psi]
Pressure
Set Point
01500
9/16-18 UNF
M
PSPST-NO
SPST-NC
P
Output
N
Base
N
M
Actuation/
Application Options
A
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
JG1/8 BSPP
L3/8-24 UNF
T
C
Rising,
field adjustable*
Falling,
field adjustable*
* Field adjustable option is only
available for:
1. Blade and screw terminations
(SPDT, SPNO, SPNC)
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
Mbar,
true gage*
Tpsig,
true gage*
A1/4-18 NPT
B1/8-27 NPT
D1/8-27 PTF
RR1/8 BSPT
VR1/2 BSPT
M7/16-20 UNF
P1/2-14 NPT
TM10 × 1.0
Cold-rolled
steel
N
M
LTNB diaphragm
(Low-temp Buna N)
HNBR diaphragm
(Hydrogenated Nitrile
Butadiene Rubber)
H3/4-16 UNF
AA
Connector
Type
EA
HA
BA
AA 1/4 in Spade
Terminals
Screw
Terminals
10-inch Cable, 18 AWG
(Wire Out, No Connector)
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
NA
PA
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
RA
SA
WA 4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
XA
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000287 (18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
YA
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
AB
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB 10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
*Blade and screw electrical
terminations are available
with only the the true gage
option.
**Connector cavity and roll
forming area filled with epoxy
to meet dunk test sealing
capability.
Gpsig,
sealed gage
with epoxy**
Hbar,
sealed gage
with epoxy**
CB
6-inch Cable with Amp
Super Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
A
Standard
switch
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
GWith conduit
sleeve
#8-32 screw with
external tooth
lockwasher***
L304,8 mm [12 in]
total wire length
w/ shrink sleeve
F304,8 mm [12 in]
total wire length
K914,4 mm [36 in]
total wire length
E
EPDM diaphragm
(Ethylene-Propylene-
Diene Monomer)
J
B
Brass
V
Stainless
steel
ZR1/4 BSPT
YG1/4 BSPP
HWith Vibra seal
for threads
M914,4 mm [36 in]
total wire length
w/ shrink sleeve
Packaging
Options
01
01 Individually
boxed units
15
20 150 units in
bulk packaging
25 individual
boxes packed in
bulk packaging
25
30 150 individual
boxes packed in
bulk packaging
25 units in
bulk packaging
***applicable only for
screw terminal version.
DA Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)
For example, MHR01500PFPVMAAA01 defines a medium pressure, high burst switch, rising factory set, non-adjustable set
point, 150 psi set point, psig, sealed gage pressure unit, 1/418 NPT port type, SPSTNO contacts output, stainless steel base,
LTNB diaphragm, and spade terminal connectors.
Safety and Productivity Solutions 13
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: MEDIUM PRESSURE
ME
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
ME Series
Medium
Pressure
Switch
C
1/2-20 UNF
E
F
M14 x 1.5
M12 x 1.5
G
F
Port Type
1,72 bar to 24,13 bar
[25 psi to 350 psi]
Pressure
Set Point
01500
9/16-18 UNF
Y
M
P
SPST-NO,
gold-plated contacts
SPST-NC,
gold-plated contacts
SPDT-NO/NC,
gold-plated contacts
P
Output
N
Base
VK
Actuation/
Application Options
A
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
J
G1/8 BSPP
M
7/16-20 UNF
Packaging
Options
01
01
Individually
boxed units
15
20
150 units in
bulk packaging
25 individual
boxes packed in
bulk packaging
T
C
Rising,
field adjustable*
Falling,
field adjustable*
* Field adjustable option is only
available for:
1. Blade and screw terminations
(SPDT, SPNO, SPNC)
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
M
bar,
true gage
T
psig,
true gage
A
1/4-18 NPT
B
1/8-27 NPT
D
1/8-27 PTF
V
R1/2 BSPT
Z
R1/4 BSPT
R
R1/8 BSPT
T
M10 × 1.0
Y
G1/4 BSPP
V
Cold-rolled
steel with
zinc plating
H
K
Kapton® diaphragm
(Teflon
®
coated),
Nitrile O-ring1
Kapton
®
diaphragm
(Teflon
®
coated),
EPDM O-ring2
1 Air, Petroleum-based
hydraulic fluid, engine oil
2 Glycol-based fluid
H
3/4-16 UNF
AA
Connector
Type
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
CA
DA
BA
AA
1/4 in Spade
Terminals
Screw
Terminals
Deutsch DT04-3P-E005
(3-Pin Connector)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)
FA
GA
EA
10-inch Cable, 18 AWG
(Wire Out, No Connector)
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
HA
JA
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
NA
PA
RA
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
UA
VA
TA
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
YA
WA
4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
AB
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB
GB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
Blade and screw electrical
terminations are available
with only the the true gage
option.
G
psig,
sealed gage
with epoxy
H
bar,
sealed gage
with epoxy
F
E
NO, with 510 /
0.5 W & 160 /
0.5 W resistors
NC, with 3000 /
0.125 W resistor
XA
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000287 (18 AWG)
CB
6-inch Cable with Amp
Super Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
A
B
Standard
switch
With 3 shrink
sleeve
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
F
G
304,8 mm [12 in]
total wire length
With conduit
sleeve
J
#8-32 screw with
external tooth
lockwasher
R
With port neck
O-ring for LPS
*** For screw terminal option
only
E
With 1/8 W resistor
between terminals
H
With Vibra seal
for port threads
K
914,4 mm [36 in]
total wire length
Stainless
steel
25
30
150 individual
boxes packed in
bulk packaging
25 units in
bulk packaging
For example, MER01500PFPVKAAA01 defines a medium pressure switch, rising factory set, non-adjustable set point, 55 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTNO gold-plated contacts output, stainless steel base, Kapton®
diaphragm (Teflon® coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed
units.
14 sensing.honeywell.com
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
NOMENCLATURE: LOW PRESSURE
LP
Series
R
F
Rising
factory set,
non-adjustable
Falling
factory set,
non-adjustable
Set Point
R
P
B
psig,
sealed gage
bar,
sealed gage
Pressure
Unit
P
LP Series,
LE Series
Low
Pressure
Switch C1/2-20 UNF
E
FM14 x 1.5
M12 x 1.5
G
F
Port Type
0,24 bar to 10,34 bar
[3.5 psi to 150 psi]
Pressure
Set Point
00550
9/16-18 UNF
Y
M
PSPST-NO,
gold-plated contacts
SPST-NC,
gold-plated contacts
SPDT-NO/NC,
gold-plated contacts
P
Output
B
Brass
Base
VK
Actuation/
Application Options
A
NOTE:
Pressure set point
is always five digits.
For bar, the set point
value will be multiplied
by 100 and entered
in the listing. For example,
15,45 Bar is noted as
01545. This allows for
2 decimal places.
For psi, the set point
value will be multiplied
by 10 and entered
in the listing. For example,
245.5 psi is noted as 02455.
This allows for 1 decimal place.
JG1/8 BSPP
M7/16-20 UNF
Packaging
Options
01
01 Individually
boxed units
15
20 150 units in
bulk packaging
25 individual
boxes packed in
bulk packaging
T
C
Rising,
field adjustable*
Falling,
field adjustable*
* Field adjustable option is only
available for:
1. Blade and screw terminations
(SPDT, SPNO, SPNC)
2. Deutsch DT04-3P
(SPDT, SPNO, SPNC)
3. Amp Superseal 1.5 (3-pin)
(SPNO & SPNC)
Mbar,
true gage
Tpsig,
true gage
A1/4-18 NPT
B1/8-27 NPT
D1/8-27 PTF
VR1/2 BSPT
ZR1/4 BSPT
RR1/8 BSPT
TM10 × 1.0
YG1/4 BSPP
N
Cold-rolled
steel with
zinc plating H
K
Kapton
®
diaphragm
(Teflon® coated),
Nitrile O-ring1
Kapton
®
diaphragm
(Teflon® coated),
EPDM O-ring2
U
TTefzel® and Kapton®
diaphragm,
Nitrile O-ring3
Tefzel® and Kapton®
diaphragm,
EPDM O-ring4
1 Air, Petroleum-based
hydraulic fluid, engine oil
2 Glycol-based fluid
3 For high temperature
fluid media (LE Series only)
4 For high temperature
fluid media, glycol-based
fluid (LE Series only)
H3/4-16 UNF
V
Stainless
steel
AA
Connector
Type
MA
10-inch Cable w/Deutsch
DT04-2P-E005
(2-Pin Connector) (18 AWG)
CA
DA
BA
AA 1/4 in Spade
Terminals
Screw
Terminals
Deutsch DT04-3P-E005
(3-Pin Connector)
Amp Super Seal 1.5 -
282105-1
(3-Pin Connector)**
FA
GA
EA 10-inch Cable, 18 AWG
(Wire Out, No Connector)*
10-inch Cable w/Amp
Super Seal 1.5 - 282105-1
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT04-3P-E005
(3-Pin Connector) (16 AWG)*
HA
JA
KA
10-inch Cable w/M12x1
(Brad Harrison Micro) -
21032121306 Harting P/N
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Metripack
280 Delphi 15300002
(2-Pin Connector) (18 AWG)*
10-inch Cable w/
Din43650-C
(3-Pin Connector) (18 AWG)*
LA
10-inch Cable w/Packard
Weatherpack Male Terminal -
12020827 (3-Pin Connector)
(18 AWG)*
NA
PA
RA
4-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(16 AWG)
3-inch Cable w/Packard 2P
Tower Connector -
12015792 (2-Pin Connector)
(18 AWG)
2.75-inch Cable w/Packard
2P Shroud Connector -
12010973 (2-Pin Connector)
(18 AWG)
EB
4.5-inch Cable w/Packard
Shroud Connector 12015792
(2-Pin Connector) (18 AWG)
UA
VA
TA
SA
5.5-inch Cable w/ITT
Cannon 2P Sure-Seal
Circular Connector -
SS2R-120-1804-000 (2-Pin
Connector) (18 AWG)
8.5-inch Cable w/ITT
Cannon 3P Sure-Seal
Circular Connector -
SS3R-120-8551-001 (3-Pin
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT06-3S-EP06 (3-Socket
Connector) (16 AWG)*
10-inch Cable - Vacuum
Impregnated w/Deutsch
DT04-3P-E005 (3-Pin
Connector) (16 AWG)*
YA
WA 4.5-inch Cable w/ 1/4 in
Spade Terminals 6,3 mm x
0,8 mm (16 AWG)*
6-inch Cable w/Amp
Super Seal 1.5 - 282104-1
(2-Pin Connector) (18 AWG)*
ZA
AB
BB
10-inch Cable w/Metripack
150 Delphi 12129615
(3-Pin Connector) (18 AWG)*
10-inch Cable w/Deutsch
DT06-2S-CE06 (2-Socket
Connector) (18 AWG)
Deutsch DT04-2P-E005
(2-Pin Connector)
DB
10-inch Cable w/AMP 2,5 mm
System Series Connector
1-967402-1 (18 AWG)*
FB
GB
10-inch Cable w/Metripack
150 Delphi 12052641
(2-Pin Connector) (18 AWG)
8.5-inch Cable w/Deutsch
Plug HD 16-3 96S
(3-Pin Connector) (16 AWG)
*These connectors are designed for dual circuit (SPDT) by default.
They can be used for single-circuit applications (SPNC/SPNO) by
making suitable connections. Refer to wiring diagram.
**For electrical termination with SPST option, only SPNO
configuration is available. SPNC configuration cannot be provided.
Blade and screw electrical
terminations are available
with only the the true gage
option.
True gage option is available
only up to 20 psig set
point for integral connectors
and wire out electrical
terminations.
Gpsig,
sealed gage
with epoxy
Hbar,
sealed gage
with epoxy
F
ENO, with 510 /
1 W & 160 /
1 W resistors****
NC, with 3000 /
0.125 W resistor
XA
10-inch Cable w/ Metripack
2-Pin Shroud Connector
153000287 (18 AWG)
CB
6-inch Cable with Amp
Super Seal 1.5 - 282080-1
(2-Pin Connector) (18 AWG)
A
B
Standard
switch
With 3 shrink
sleeve
C
D
With shrink
sleeve
(plastic coating)
With shrink
sleeve
(acrylic coating)
F
G
304,8 mm [12 in]
total wire length
With conduit
sleeve
H
K
With Vibra seal
for port threads
914,4 mm [36 in]
total wire length
L304,8 mm [12 in]
total wire length with
acrylic sleeve
GNC with 510 /
0.5 W and 160 /
0.5 W resistors****
25
30 150 individual
boxes packed in
bulk packaging
25 units in
bulk packaging
M
914,4 mm [36 in]
total wire length with
acrylic sleeve
*** For screw terminal option
only
**** Available only on LP Series
For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTNO gold-plated contacts output, stainless steel base, Kapton®
diaphragm (Teflon® coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed
units.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship during the appli-
cable warranty period. Honeywell’s standard product warranty
applies unless agreed to otherwise by Honeywell in writing;
please refer to your order acknowledgement or consult your
local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items that Honeywell, in its sole discretion, finds defec-
tive. The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyers
sole responsibility to determine the suitability of the product in
the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
500940815EN IL50 GLO
October 2016
© 2016 Honeywell International Inc. All rights reserved.
® DuPont™, Teflon®, Tefzel®, and Kapton® are trademarks or registered trademarks of E.I. du Pont de Nemours and Company
m WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For
application assistance, current
specifications, pricing or name
of the nearest Authorized
Distributor, contact your local
sales office. To learn more
about Honeywell’s sensing and
switching products,
call +18152356847 or
18005376945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
ADDITIONAL MATERIALS
The following associated literature is available at
sensing.honeywell.com:
Product range guide
Product line guide
Technical note: Smart Diagnostic Technology
Product application-specific information
Application Note: Honeywell Pressure Switches
Sensors and switches in front loaders
Sensors and switches in mobile cranes
Sensors and switches in oil rig applications
Industrial product line card
Honeywell Safety and Productivity Solutions
9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com