Panel Mount Datasheet Dual GN Series * Current rating 25 and 40 Amps * Output voltage 24-280 VAC and 48-660 VAC * Direct bond copper substrate * Back to back dual SCR output * 4000 VAC optical isolation * Zero Voltage and Instantaneous Turn-On * UL/cUL Recognized, CE Compliant PRODUCT SELECTION 1/4" Quick Connect 280 VAC 25 A 40 A Control Voltage 1/4" Quick Connect 660 VAC 40 A 25 A Locking Connector 280 VAC 25 A 40 A 4-15 VDC 84140000 84140200 84140500 84140600 84140800 84140900 17-32 VDC 84140410 84134210 84140510 84140610 84140810 84140910 AVAILABLE OPTIONS Series Rated Load Current Control Voltage Operating Voltage 84140 0 1 U 0 0: 24-280 VAC 1/4" Quick Connect 280 VAC 0: 25 Amp/Zero Voltage Turn-On 1: 25 Amp/Instantaneous Turn-On 2: 40 Amp/Zero Voltage Turn-On 3: 40 Amp/Instantaneous Turn-On 0: 4-15 VDC 1: 17-32 VDC 1/4" Quick Connect 660 VAC 5: 25 Amp 6: 40 Amp 0: 4-15 VDC 1: 17-32 VDC 0: 48-660 VAC/Zero Voltage Turn-On 1: 48-660 VAC/Instantaneous Turn-On Locking Connector 280 VAC 8: 25 Amp 9: 40 Amp 0: 4-15 VDC 1: 17-32 VDC 0: 24-280 VAC/Zero Voltage Turn-On 1: 24-280 VAC/Instantaneous Turn-On OUTPUT SPECIFICATIONS (1) Description Operating Voltage [Vrms] Transient Voltage(t=1 min.) [Vpk] Maximum Off-State Leakage Current @ Rated Voltage (@ max. line voltage) [mArms] 280 VAC 660 VAC 24-280 550 0.1 48-660 1000 0.25 25 A 40 A 25 100 275/300 85 1.4 0.6 380/370 500 40 100 710/750 150 1.3 0.4 2520/2320 500 OUTPUT SPECIFICATIONS (1) Description Maximum Load Current [Arms] Minimum Load Current [mArms] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 1 Second surge current (50/60 Hz @ Ta=25C) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [C/W] Maximum 1/2 Cycle I t for Fusing (50/60Hz) [A sec] Maximum Off-State dv/dt @ Maximum Rated Voltage [V/sec] Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description Control Voltage Range [Vdc] Minimum Turn-On Voltage [Vdc] Must Turn-Off Voltage [Vdc] Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance [Ohms] Maximum Turn-On Time [msec] (2) Maximum Turn-Off Time [msec] 84140x0x 84140x1x 4-15 4 1 7.5 34 500 17-32 17 1 13 24 1500 1/2 Cycle 1/2 Cycle GENERAL SPECIFICATIONS (1) Description Parameters -40 to 80 C Ambient Operating Temperature Range Ambient Storage Temperature Range Input to Output Isolation Input/Output to Ground Isolation Input to Output Capacitance Operation Frequency Housing Material Weight (typical) -40 to 100 C 4000 Vrms 2500 Vrms 8pF 47 to 63 Hz UL94 V-0 (self extinguishing) 3.2 oz (91.5g) GENERAL NOTES (1) All parameters at 25C unless otherwise specified. (2) Turn-on time for Instantaneous turn-on versions is 0.02 msec. For additional information or specific questions, contact Crydom Technical Support. WIRING DIAGRAM Load AC AC V V 2A ( ) 2B ( ) 1A ( ) Load 1B ( ) S O L I D S TAT E R E L AY Input A + - + Input B - Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet EQUIVALENT CIRCUIT BLOCK DIAGRAMS -DC Trigger Circuit +DC + OUTPUT INPUT 2A AC 1A AC Current Limiter -DC Trigger Circuit +DC + OUTPUT INPUT 2B AC 1B AC Current Limiter MECHANICAL SPECIFICATIONS (1) Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 1.78 [45.3] Mounting Hole/Slot 0.19 [4.9] DIA. 1.17 [29.7] 1.00 [25.4] 0.18 [4.7] 0.56 [14.3] S O L I D S TAT E R E L AY Input A + - 1.87 [47.5] 1.21 [30.6] 0.86 [21.8] + Input B - 0.60 [15.2] 2.30 [58.4] 0.74 [18.8] 0.45 [11.5] Pin .025 SQ .100 CENTERS (4 places) Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 1.31 [33.2] Mating Connector for 841408xxx and 841409xxx Molex # 50-57-9404 without pins Crimp Pins Molex # 16-02-0103 Panel Mount Datasheet THERMAL DERATE INFORMATION 25 A 0.7C/W 1C/W 40 A 0.5C/W 2C/W 1.5C/W Combined Channel Output Current (Amp) Combined Channel Output Current (Amp) 50 40 30 20 10 0 20 30 40 50 60 70 80 Ambient Temperature (C) 80 70 60 50 40 30 20 10 0 20 30 1C/W 40 1.5C/W 50 60 2C/W 70 80 Ambient Temperature (C) AGENCY APPROVALS EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Certified according to EN 62314:2006 IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 E79183 LR 38595 Rev. 092616 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSI ONE. * Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra * * Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provochera la morte o di lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. * * * Panel Mount Datasheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)