DT-39-B01W-XX Barrier Terminal Blocks > Single Row Date:2019-05-26Version:1.1 The web catalog is for reference only. Dinkle remains the right of product modification and engineering change of the design. The final product is made according to engineering drawing. Product Description Pitch: 8.25mm , #6-32, 300V, 20A General information Short description Category Pitch (mm) Color Connection method Barrier terminal blocks , Screw connection Single Row 8.25 Black(default) Screw connection Type of locking Without Pin demensions (Thickness x Width)(mm) 0.8X1.2 PCB hole diameter (mm) 1.6~1.7 Level Single Row Material information Insulation material Insulation material group Flame retardant rating , compliant with UL94 Conductor material Plating of conductor surface TEL: +886-2-8069-9000 / E-mail: service@dinkle.com (c) DINKLE ENTERPRISE CO ,LTD. ALL RIGHT RESERVED PA66 I V0 Copper Alloy Tinned 1/4 Connection data-IEC Rated current (A) 24 Rated voltage (II/2)(V) 630 Rated voltage (III/2) (V) 320 Rated voltage (III/3)(V) 320 Rated impulse voltage (II/2)(KV) 4 Rated impulse voltage (III/2)(KV) 4 Rated impulse voltage (III/3)(KV) 4 Conductor cross section solid. min (mm) 0.2 Conductor cross section solid.max (mm) 2.5 Conductor cross section stranded. min (mm) 0.2 Conductor cross section stranded. max (mm) 2.5 2 conductors with same cross section, solid, max (mm) 1.5 2 conductors with same cross section, stranded, max (mm) 1.5 Screw thread #6-32 Slotted screwdriver size (Blade thickness x Width)(mm) 0.8x4.0 Philips screwdriver size PH2 Rated torque (N.m) 1.4 Recommend tightening torque. min (N.m) 0.8 Recommend tightening torque. max (N.m) 1.4 Stripping Length (mm) 6~7 Connection data-UL Rated voltage (UL/CUL Group B)(V) 300 Rated current (UL/CUL Group B)(A) 20 Rated voltage (UL/CUL Group D)(V) 300 Rated current (UL/CUL Group D)(A) 10 Min. solid wire connection (AWG) acc. to UL/CUL 22 Max. solid wire connection AWG acc. to UL/CUL 12 Min. stranded wire connection AWG acc. to UL/CUL 22 Max. stranded wire connection AWG acc. to UL/CUL 12 Environment & Safety Back of the hand protection (YES or NO) TEL: +886-2-8069-9000 / E-mail: service@dinkle.com (c) DINKLE ENTERPRISE CO ,LTD. ALL RIGHT RESERVED YES 2/4 Operating temperature. max (C) 11.005 Operating temperature. min (C) -40 UL Recognized Wire Range (Group B)(AWG) 22~12 Rated voltage (Group B)(V) 300 Rated current (Group B)(A) 20 Wire Range (Group C)(AWG) 22~12 Wire Range (Group D)(AWG) 22~12 Rated voltage (Group D)(V) 300 Rated current (Group D)(A) 10 CUL Recognized Wire Range (Group B)(AWG) 22~12 Rated voltage (Group B)(V) 300 Rated current (Group B)(A) 20 Wire Range (Group C)(AWG) 22~12 Wire Ranget (Group D)(AWG) 22~12 Rated voltage (Group D)(V) 300 Rated current (Group D)(A) 10 VDE Approval Wire Range (mm) Rated current (A) 0.2~2.5 24 Drawings TEL: +886-2-8069-9000 / E-mail: service@dinkle.com (c) DINKLE ENTERPRISE CO ,LTD. ALL RIGHT RESERVED 3/4 Approvals TEL: +886-2-8069-9000 / E-mail: service@dinkle.com (c) DINKLE ENTERPRISE CO ,LTD. ALL RIGHT RESERVED Powered by TCPDF (www.tcpdf.org) 4/4