Industry’s smallest fused disconnect
offers superior circuit protection
Delivers up to 200 kA
SCCR in a compact,
nger-safe design.
Product description:
Eaton's revolutionary
Bussmann™ series Compact
Circuit Protector (CCP) is
designed as a fused branch
circuit rated disconnect with
a footprint 2/3 the space
required by a traditional
fusible switch.
Available in both Class CC
and Bussmann series CF
CUBEFuse™ versions, the
CCP features high 200 kA
Short-Circuit Current Rating
(SCCR) at 600 V that can
help increase equipment
SCCR. These high ratings
and compact design make
the CCP ideal for industrial
control panels, machinery
and HVAC applications.
Features and benefits:
With just 2/3 the space
required by a traditional
fusible switch, the CCP
saves panel space.
200 kA SCCR with
Bussmann series
Low-Peak™ CUBEFuse
and Class CC fuses helps
provide high equipment
SCCR.
UL® 98 Listed,
horsepower rated fused
disconnect.*
Built-in switch/fuse
interlock helps prevent
fuse removal while
energized.
Standard open fuse
indication speeds
troubleshooting.
No tools required for
mounting onto DIN-Rail.
Available in 1-, 2- and
3-pole versions.
3-pole CUBEFuse version
The Bussmann series
CUBEFuse has a small
footprint and a high level of
protection with ratings up to
100 A, 600 Vac and a 200 kA
SCCR.
* Class CC and CF versions with
time-delay fuses.
BUSSMANN
SERIES
Compact Circuit Protector
Agency information:
UL Class CC fuse version
UL 98 Listed, File E302370,
Guide WHTY
cULus to CSA® Standard 22.2 No. 4-04,
File 302370, Guide WHTY7
RoHS compliant
CE compliant
UL midget fuse version
UL 508 Listed
cULus Certied 22.2 No. 14-05
CE Compliant
RoHS compliant
10x38 IEC® Class aM and gG/gl fuse
version
IEC 60947-3 AC23A
IEC 60947-3 DC23A
CE Compliant
RoHS compliant
Wire range:
18-6AWG single or dual rated (same size
wire), solid or stranded 4AWG single,
75ºC Cu only
Torque rating:
18-10AWG 20lb-In
8-4AWG 35lb-In
Poles:
1-, 2- and 3-pole: AC version
1-pole: DC version
Construction
Finger-safe, IP20 compliant with 10AWG
or larger wire
Operating temperature:
-20ºC to 75ºC*
Flammability rating:
UL 94V0
Padlockable:
Yes
Local indication:
Yes
Mounting:
DIN-Rail
1-pole Class 80 Vdc CCP
1-, 2-, and 3-pole Class CC and midget CCP
* For fuse performance under or above 25ºC, consult fuse performance charts in Eaton's Bussmann series Selecting Protective Devices (SPD) handbook
(Number 3002).
Amp
rating
Fuse
Class
Number
of
poles Volts SCCR
Max horsepower rating
Wire size/
(torque†††)
Wire
type
Part
number Agency information
120
Vac
240
Vac
480
Vac
600
Vac
30 CC 1 600Vac 200kA 0.5
Single/dual
8-6AWG sol/
str
Single
4AWG sol/
str
Fork
terminal††
75°C
Cu
or
higher
CCP-1-30CC UL 98 Listed, cULus 22.2, No. 4-04
30 CC 2 600Vac 200kA 2 CCP-2-30CC UL 98 Listed, cULus 22.2, No. 4-04
30 CC 3 600Vac 200kA 3 5 7. 5 CCP-3-30CC UL 98 Listed, cULus 22.2, No. 4-04
30 UL
midget 1240Vac10kA
CCP-1-30M UL 508 Listed, cULus 22.2, No. 14-05
32* 10x38 IEC 400Vac120kAIEC 60947-3, AC-23A
30 UL
midget 2240Vac10kA
CCP-2-30M UL 508 Listed, cULus 22.2, No. 14-05
32* 10x38 IEC 400Vac120kAIEC 60947-3, AC-23A
30 UL
midget 3240Vac10kA
CCP-3-30M UL 508 Listed, cULus 22.2, No. 14-05
32* 10x38 IEC 400Vac120kAIEC 60947-3, AC-23A
30 CC 1 80Vdc20kA CCP-1-DCC UL 98 Listed, CSA 22.2, No. 4-04
30 CC 1 80Vdc10kA CCP-1-DCM UL 508 Listed, cULus 22.2, No. 14-05
32* 10x38 IEC IEC 60947-3, DC-23A
* 32A Class aM, 25A Class gG.
† SCCR may be lower, refer to installed fuse data sheets.
†† Fork terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG.
††† - 18-10AWG; 20 lb-In
- 8-4AWG; 35 lb-In
Ratings
Features for CCP CC, midget and 10x38mm versions
Recomended fuse types
Class CC
AC voltage
Midget Class CC Midget
LP-CC KTK LP-CC KLM
KTK-R FNM
FNQ
BAF
10X38 IEC
Part number
family
IEC
Class
C10G gG/gL
aMC11M
DC voltage
Agency information:
UL 98 Listed, File E302370, Guide WHTY
cULus to CSA Standard 22.2 No. 4-04,
File 302370, Guide WHTY7
RoHS compliant
CE compliant
Ampacity rejection:
CCP_CF disconnects will not accept
CUBEFuse amp ratings greater than the
switch rating.
Construction:
Finger-safe, IP20 compliant with 10AWG
or larger wire.
Amp ratings:
30 A
60 A
100 A
Wire range (75°C Cu or higher):
30-60A
18-6AWG, single/dual, solid/
stranded
4AWG, single/solid/stranded
100A
8-10AWG, single, solid/stranded
8-1AWG, single, stranded
6AWG, dual, stranded
Torque:
30-60A
18-10AWG, 20 lb-in
8-6AWG, 35 lb-in
4AWG, 35 lb-in
100A
8-10AWG, 25 lb-in
8-1AWG, 35 lb-in
6AWG, 45 lb-in
Poles:
1-, 2- and 3-pole
Operating temperature:
-20ºC to 75ºC*
Flammability rating:
UL 94V0
Padlockable:
Yes
Local indication:
Yes
Mounting:
DIN-Rail
1- and 2-pole 30A 3-pole 60A
Ratings
Amp
rating
UL
fuse
Class
Number
of
poles Volts SCCR
Max horsepower rating* Wire size
(See note
for torque†)
Wire
type
Part
number Agency information
120
Vac
240
Vac
480
Vac
600
Vac
30 CF 1 600Vac 200kA 1.5
Single/dual
18-6AWG sol/str
Single
4AWG sol/str
Fork terminal**
75°C Cu
or
higher
CCP-1-30CF UL 98 Listed, cULus 22.2, No. 4-04
125Vdc 100kA
30 CF 2 600Vac 200kA 3 CCP-2-30CF UL 98 Listed, cULus 22.2, No. 4-04
125Vdc 100kA
30 CF 3 600Vac 200kA 5 15 10 CCP-3-30CF UL 98 Listed, cULus 22.2, No. 4-04
60 CF 1 600Vac 200kA 3 CCP-1-60CF UL 98 Listed, cULus 22.2, No. 4-04
125Vdc 100kA
60 CF 2 600Vac 200kA 7. 5 CCP-2-60CF UL 98 Listed, cULus 22.2, No. 4-04
125Vdc 100kA
60 CF 3 600Vac 200kA 7. 5 20 10 CCP-3-60CF UL 98 Listed, cULus 22.2, No. 4-04
100 CF 1 125Vac
600Vac
100kA
200kA 5 Single
8-10AWG sol/str
8-1AWG str
Dual 6AWG str
Fork terminal**
CCP-1-100CF UL 98 Listed, cULus 22.2, No. 4-04
100 CF 2 125Vac
600Vac
100kA
200kA 10 CCP-2-100CF UL 98 Listed, cULus 22.2, No. 4-04
100 CF 3 600Vac 200kA 20 50 50 CCP-3-100CF UL 98 Listed, cULus 22.2, No. 4-04
* With time-delay Low-Peak CUBEFuse.
** Fork terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange,
wire size 12-10AWG.
30-60A: - 18-10AWG 20 lb-In
- 8-6AWG 35 lb-In
- 4AWG 35 lb-In
70-100A: - 8-10AWG single 25 lb-In
- 8-1AWG single 35 lb-In
- 6AWG dual 45 lb-In
* For fuse performance under or above 25ºC, consult fuse performance charts in Eaton's Bussmann series Selecting Protective Devices (SDP) handbook
(Number 3002).
Features for CCP_CF CUBEFuse version
Eaton, Bussmann, CUBEFuse and
Low-Peak are valuable trademarks of Eaton
in the US and other countries. You are not
permitted to use the Eaton trademarks
without prior written consent of Eaton.
CSA is a registered trademark of the
Canadian Standards Group.
IEC is a registered trademark of the
International Electrotechnical Commission.
UL is a registered trademark of the
Underwriters Laboratories, Inc.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton.com/bussmannseries
© 2017 Eaton
All Rights Reserved
Printed in USA
Publication No. 3191
June 2017
Auxiliary contact
NO+NC contact output to indicate the status
of the switching mechanism on the
Bussmann series CCP.
Agency information:
UL 98 File E155130, guide WHTY2
cULus to CSA Standard 22.2 Number 4-04
IEC 60947-5-1
Specications:
Rated ampacity
5 A
Rated voltage
240 Vac
NC/NO contacts are closed/open when the
CCP switch is in the “ON” position (closed)
Flammability rating
UL 94V0
Remote fuse monitoring
A resetable three-phase fuse monitor that
integrates with the I/O card in a
Programmable Logic Controller (PLC).
Agency information:
UL 98 File E155130, guide WHTY2
cULus to CSA Standard 22.2 Number 4-04
Specications:
Power input
24 Vdc / 10mA max
Output signals
Digital 0 Vdc (low), 24Vdc (high)
0Vdc low - fuse is good
24Vdc high - fuse has opened
When the fuse opens, the output signal is
sent high and will remain high until the unit
is reset.
Rated impulse voltage
8kA
Local indication
Two distinct LEDs indicate unit power
(green) and open fuse (red). Upon the
replacement of the fuse, the actuation of
the reset switch will reset the open fuse
LED.
Flammability rating
UL 94V0
Accesories
CCP-PLC-IND
(Includes fork terminals)
CCP-AUX
CCP-AUX accessories
Description
Max per
CCP
Signal
output
Agency
information
Catalog
number
Auxiliary contacts
NO+NC for switch
status up to 60A
1 per CCP
(1-, 2- or
3-pole)
5A/240VAC
UL 98
Recognized,
cURus 22.2
No. 4-04,
IEC 60947-5-1
AC-15
CCP-AUX
Auxiliary contacts
NO+NC for switch
status 70 to 100A
1 per CCP
(1-, 2- or
3-pole)
5A/240Vac
UL 98
Recognized,
CSA C22.2
No. 4-04
CCP-AUX-100
De-energize all circuits before installing or removing any CCP-AUX devices and
follow all prescribed safety procedures.
PLC fuse monitor
Description
Max
per
CCP
Signal
output
to PLC
Min.
circuit
volts
Agency
information
Catalog
number
Wired remote
fuse indication
for PLC
applications up
to 60A
1 per
CCP
(1, 2- or
3-Pole)
24Vdc/
10mA 100Vac
UL 98 Recognized,
cURus 22.2
No. 4-04
CCP-PLC-IND
Wired remote
fuse indication
for PLC
applications 70
to 100A
UL 98 Recognized,
CSA C22.2 No. 4-04 CCP-PLC-100
De-energize all circuits before installing or removing any
CCP-PLC-IND devices and follow all prescribed safety procedures.
See data sheet No. 1157 for more information.
Follow us on social media to get the
latest product and support information.
For Eatons Bussmann series
product information,
call 1-855-287-7626 or visit:
Eaton.com/bussmannseries