SPECIFICATION CONTROL DRAWING CHEMINAX 50 OHM, AWG 26, 7 STRANDS OF AWG 34, COAXIAL CABLE 5026A1311 Date: 6-17-94 Revision: 8 THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200 CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. CONDUCTOR AWG 26, 7 Strands of AWG 34, Tin-Coated Copper < DIELECTRIC 003 Rayfoam L Color - Natural 064 +| SHIELD AWG 38 Tin-Coated Copper 084 (nominal) = J le JACKET 089 Thermorad S (maximum) Outer jacket color will be black (designated by a .0" appended to the part number, e.g., 5026A 1311-0) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681 CHARACTERISTIC IMPEDANCE CAPACITANCE VELOCITY OF PROPAGATION 50 + 2 ohms, Method A 27.1 pF/ft. (nominal) 28.2 pF/ft. (maximum) 75% (nominal) ADDITIONAL REQUIREMENTS ELECTRICAL CONDUCTOR RESISTANCE INSULATION RESISTANCE JACKET FLAWS SPARK TEST IMPULSE TEST VOLTAGE WITHSTAND (DIELECTRIC) ENVIRONMENTAL. AGING STABILITY FLAMMABILITY HEAT SHOCK LOW TEMPERATURE- COLD BEND VOLTAGE WITHSTAND (POST ENVIRONMENTAL) PHYSICAL INSULATION (DIELECTRIC) ELONGATION TENSILE STRENGTH JACKET ELONGATION TENSILE STRENGTH JACKET THICKNESS SHIELD COVERAGE WEIGHT 42.6 ohms/1GOOft. (nominal) 10,000 megohms (minimum) for 1000 ft. 4.0 kV, 60 Hz (rms) 6.0 kV, (peak) 1000 volts (minimum) 135C/-55C/2.50 inch mandrel Method C 225C -55C/2.50 inch mandret 1000 volts (rms), 1 minute 50% (minimum) 1000 Ibf/in? (minimum) 250% (minimum) 2000 lbff/in? (minimum) .008 inch (minimum) .010 inch (nominal) 90% (minimum) 5.7 Ibs/1000 ft. (nominal) Raychem Raychem Corporation 300 Consatuton Orve Menlo Park Calfornia 94025 4-806-2 RAYCHEM FAX: 415-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HERIN. REFER. NCE DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.