Nominal capacity @ 4 mA, to 2 V 19 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 230 mA
Maximum pulse current capability 500 mA
Weight 93 g (3.28 oz)
Volume 51 cc
Operating temperature range -55 ºC to +85 ºC
Li metal content approx. 5 g
U.L. Component Recognition, MH 12193
SUFFIX- /S STANDARD 15-5930-21500
SUFFIX- /T SOLDER TABS 15-5930-31500
TECHNICAL DATA
(Typical values @+ 25ºC for batteries stored for one year or less)
International size reference: D, ER32L615
MODEL TL-5930
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
TERMINATIONS & ORDERING NO.
iXtra - Long Term High Performance
ECN 1501879 Rev. C 11/08
Page 1 of 2
DISCHARGE CHARACTERISTICS @ +25ºC
33
~100 mA
(9.0 Ah)
180
~20 mA
(16.9 Ah)
56
~60 mA
(13.1 Ah)
330
~10 mA
(18.2 Ah)
910
~4 mA
(19.0 Ah)
18 k
~200 µA
(15.4 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1 10 100 1000 10000 100000
Hours
Volts
VOLTAGE VS. TEMPERATURE
100 mA
20 mA
2 mA
0.5 mA
100 µA
50 µA
2.3
2.5
2.7
2.9
3.1
3.3
3.5
3.7
-50 -30 -10 10 30 50 70 90
ºC
Volts CAPACITY VS. CURRENT
-30 °C
0 °C
25 °C
55 °C
72 °C
0.1 1 10 100
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
mA
Ah
VOLTAGE RESPONSE AFTER STORAGE
After 1 year
After 2 years
After 5 years
After 8 years
After 10 years
2.4
2.6
2.8
3.0
3.2
3.4
0 200 400 600 800 1000 1200
msec
Volts
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
Low self discharge rate
Bobbin construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
Restricted for transportation (Class 9 worldwide)
Non-restricted within the US
CELL FEATURES
TL-5930
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
iXtra - Long Term High Performance
ECN 1501879 Rev. C 11/08
Page 2 of 2
MAIN APPLICATIONS
Utility meters (elect., water & gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power (ULP) devices
Others
Cells should be stored in a clean
& dry (less than 30 % RH) area
Temp. should not exceed +30 ºC
STORAGE CONDITIONS
For updated information please visit
our website www.tadiranbat.com
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 8 years
After 10 years
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
0 20 40 60 80 100 120
msec
Volts VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 8 years
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
0 20 40 60 80 100 120
msec
Volts
Pulse applied: 60 mA for 100 msec
Temperature: RT
Background current: 50 µA
Pulse applied: 60 mA for 100 msec
Temperature: RT
Background current: 100 µA
Pulse applied: 60 mA for 1 sec
Storage: RT
Background current: None