2ds_61005_en_ds2y: 230712J
RATING
1. Coil data
Single side stable type
2. Specifications
* Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Nominal coil
voltage Pick-up voltage
(at 20C 68F)Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)Nominal operating
power Max. applied voltage
(at 50C 122F)
1.5V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
132.7mA 11.3
200mW 200%V of
nominal voltage
3V DC 66.7mA 45
5V DC 40mA 125
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
24V DC 8.3mA 2,880
48V DC 6.3mA 7,680300mW
Characteristics Item Specifications
Contact Arrangement 2 Form C
Initial contact resistance, max. Max. 50 m (By voltage drop 6 V DC 1A)
Contact material Ag+Au clad
Rating
Max. switching power 60 W, 62.5 VA (resistive load)
Max. switching voltage 220 V DC, 250 V AC
Max. switching current 2 A
Max. carrying current 3 A
Minimum operating power Approx. 98 mW (147 mW: 48 V)
Nominal operating power Approx. 200 mW (300 mW: 48 V)
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 1,000 Vrms for 1min. (Detection current: 10mA.)
FCC surge breakdown voltage between contacts
and coil 1,500 V
Temperature rise (at 20C 68F) Max. 65C with nominal coil voltage across coil and at nominal switching capacity
Operate time [Set time] (at 20C 68F)Approx. 4 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)Approx. 3 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 108
Electrical 5105 (1 A 30 V DC), 105 (2 A 30 V DC)
Conditions Conditions for operation, transport and storage* Ambient temperature: –40C to +70C –40F to +158F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 60 cpm
Unit weight Approx. 4g .14oz