SPF Series
• SIP SSR
• Ratings to 25A (forced air) @ 480 VAC
• SCR output for heavy industrial loads
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage 25A 25A 25A
SPF240D25
4-15 VDC SPF380D25 SPF480D25
15-32 VDC SPFE240D25 SPFE380D25 SPFE480D25
18-36 VAC SPFE240A25
90-140 VAC SPF240A25
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description SPF240 SPF380 SPF480
Operating Voltage (47-63Hz) [Vrms] 12-280 48-530 48-660
Transient Overvoltage [Vpk] 600 1200 1200
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500
Maximum Load Current (Convection Air) [Arms] (3) 10 10 10
Maximum Load Current (Forced Air) [Arms] (3) 25 25 25
Minimum Load Current [Arms] 0.06 0.06 0.06
Maximum Surge Current (16.6ms) [Apk] 250 250 250
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6
Maximum I² t for fusing (8.3 msec) [A² sec] 260 260 260
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
INPUT SPECIFICATIONS (1)
Description SPF240D25 SPF380D/480D SPFExxxD25 SPF240A25 SPFE240A25
Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 VAC 18-36 VAC
Maximum Turn On Voltage 3.0 VDC 4.0 VDC 15.0 VDC 90.0 Vrms 18.0 Vrms
Minimum T urn -Off Voltage 1.0 VDC 1.0 VDC 1.0 VDC 10.0 Vrms 2.0 Vrms
Typical Input Current @ Nominal Voltage 15 mAdc 15 mAdc 15 mAdc 10 mAdc 10 mAdc
Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 14.1 k Ohm 2.1 k Ohm
Maximum Turn-On Time [msec] (4) 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 10
Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 40
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms
Minimum Insulation Resistance (@ 500 VDC) 10 9 Ohm
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range -30 to 80ËšC
Ambient Storage Temperature Range -30 to 125ËšC
Weight (typical) 0.85 oz. (25g)
Encapsulation Thermally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443,13.11.1
3) Heatsink temperature 85 ûC Maximum.
4) Turn-On Time for Random Turn-On versions 0.1 msec (DC Control Models)
WIRING DIAGRAM
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
E116950
Rev. 112911
ANNEX - ENVIROMENTAL INFORMATION