PS PRESSURE SENSOR 2002.10.23 7:58 PM Page 23 PS (ADP4) ULTRA SMALL HIGHLY SEMICONDUCTOR PRESSURE SENSOR * Base area: 8.6 .339 7.2(W) x 7.2(D) mm 7.2 .283 .283(W) x .283(D) PS inch 7.2 * Only 60% in mounting .283 10.0 .394 area and 91% in overExisting products all height of previous Piezo resistance strain gauge models (PF) Anode junction Pressure * High-level precision and linearity A high degree of precision and linear detector response have been achieved by applying the semiconductor strain gauge system. Highly reproducible based on repeated pressure. Glass base * Impressive line-up of models Highly reliable wire bonding technology Pressure High reliability die bonding technology Very strong, heat resistant body * Taking their place alongside the standard 5k bridge resistance models are those with a 3.3k resistance which is optimally suited to 5V drive circuits. * Economy model (no glass base) gives outstanding value for consumer appliances 40 kPa (0.4 kgf/cm2) and 49 kPa (0.5 * Improved ease of DIP pin insertion into printed circuit boards The ends of the DIP pins are chamfered to ensure easy insertion into printed circuit Example of pressure characteristics (when the rated pressure is between 98.1 kPa {1.0 kgf/cm2}) Drive current: 1.5 mA rated current; ambient temperature: 25C 77F 100 Output voltage, mV * Ultra-miniature size: much more compact than the PF pressure sensors offered in the past Silicon kgf/cm2) units are also available. FEATURES mall Ultra-sture minia PS PRESSURE SENSOR 50 0 0 {0} 49 {0.5} 98.1 {1} Pressure (gauge pressure), (kPa {kgf/cm2}) TYPICAL APPLICATIONS * Medical equipment: Electronic hemodynamometer * Home appliance: Vacuum cleaner * Gas equipment: Microprocessor gas meter, gas leakage detector * Industrial equipment: Absorption device, etc. ORDERING INFORMATION Ex. ADP Part No. 4 Terminal profile and direction Rated pressure 1: DIP terminal: Direction opposite the pressure inlet direction ADP4: PS pressure sensor 2: DIP terminal: Pressure inlet direction 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: A: DIP terminal: Direction opposite the pressure inlet direction Terminal Pressure Economy type (Without glass base) {approx. 0.05 kgf/cm2} {approx. 0.15 kgf/cm2} {approx. 0.35 kgf/cm2} {approx. 0.5 kgf/cm2} {approx. 1.0 kgf/cm2} {approx. 2.0 kgf/cm2} {approx. 3.5 kgf/cm2} {approx. 5.0 kgf/cm2} {approx. 8.5 kgf/cm2} {approx. 10.0 kgf/cm2} {approx. 0.4 kgf/cm2} Type 1 : Standard type (With glass base) 2: Economy type (Without glass base) 5.0k Bridge resistance Standard type (With glass base) 4.9 kPa 14.7 kPa 34.3 kPa 49.0 kPa 98.1 kPa 196.1 kPa 343.2 kPa 490.3 kPa 833.6 kPa 980.7 kPa 40.0 kPa Bridge resistance 0 : 5.0k 3 : 3.3k 3.3k DIP terminal: Pressure inlet direction DIP terminal: Direction opposite the pressure inlet direction DIP terminal: Pressure inlet direction 4.9kPa approx. 0.05kgf/cm2 ADP41010 ADP42010 ---- ---- 14.7kPa approx. 0.15kgf/cm2 ADP41110 ADP42110 ---- ---- 34.3kPa approx. 0.35kgf/cm ADP41210 ADP42210 ---- ---- 49.0kPa approx. 0.5kgf/cm2 ADP41310 ADP42310 ---- ---- 98.1kPa approx. 1.0kgf/cm2 ADP41410 ADP42410 ADP41413 ADP42413 196.1kPa approx. 2.0kgf/cm2 ADP41510 ADP42510 ---- ---- 343.2kPa 2 approx. 3.5kgf/cm ADP41610 ADP42610 ---- ---- 490.3kPa approx. 5.0kgf/cm2 ADP41710 ADP42710 ---- ---- 833.6kPa approx. 8.5kgf/cm2 ADP41810 ADP42810 ---- ---- 980.7kPa approx. 10.0kgf/cm2 ADP41910 ADP42910 ADP41913 ADP42913 40.0kPa approx. 0.4kgf/cm2 ---- ---- ADP41A23 ADP42A23 49.0kPa approx. 0.5kgf/cm2 ADP41320 ADP42320 ---- ---- 2 23 PS PRESSURE SENSOR 2002.10.23 7:58 PM Page 24 PS (ADP4) SPECIFICATIONS Economy type (Without glass base) Standard type (With glass base) Type Type of pressure Pressure medium Unit: kPa Rated pressure Unit: kgf/cm2 (approx.) 4.9 0.05 14.7 0.15 Max. applied pressure Bridge resistance Ambient temperature Storage temperature Temperature compensation range Drive current (constant current) Output span voltage Offset voltage Linearity Pressure hysteresis Offset voltage-temperature characteristics (0 to 50C 32 to 122F) Sensitivity-temperature characteristics (0 to 50C 32 to 122F) 4020 mV 0.7%FS 0.5%FS 0.6%FS 0.4%FS Gauge pressure Air (For other medium, please consult us.) 34.3 49.0 98.1 196.1 343.2 490.3 833.6 980.7 98.1 980.7 40.0 49.0 0.35 0.5 1.0 2.0 3.5 5.0 8.5 10.0 1.0 10.0 0.4 0.5 1.5 times Twice the 1.5 times the Twice Twice the rated pressure the rated pressure rated pressure rated pressure the rated pressure 50001000 3300700 3300600 50001000 -5 to +50C -20 to +100C -20 to 100C -4 to 212F (no freezing or condensation) +23 to +122F -4 to +212F -20 to +70C -40 to +120C -40 to 120C -40 to 248F (no freezing or condensation) -4 to +158F -40 to +248F 0 to 60C 5 to 45C 0 to 50C 0 to 50C 32 to 122F 32 to 140F 41 to 113F 32 to 122F 1.5 mA DC 1.0 mA DC 1.5 mA DC 10040 mV 6525 mV 43.522.5 mV 8545 mV 20 mV 15 mV 25 mV 0.3%FS 0.5%FS 0.6%FS 1.0%FS 0.3%FS 0.2%FS 0.4%FS 1.0%FS 0.7%FS 15%FS 5.0%FS 10%FS 3.5%FS 2.5%FS 10%FS 8%FS 1.3%FS 2.5%FS Notes) 1. Unless otherwise specified, measurements were taken with a drive current of 0.01 mA and humidity ranging from 25% to 85%. 2. Please consult us if a pressure medium other than air is to be used. 3. This is the regulation which applies within the compensation temperature range. 4. Please consult us if the intended use involves a negative pressure. DATA ADP41913 Drive current: 1.0 mA; temperature: 30C 86F Output voltage (mV) 50 40 30 20 10 0 1-<3> Sensitivity - temperature characteristics (%FS) ADP41913 Drive current: 1.0 mA; rating 3.5%FS ADP41913 Drive current: 1.0 mA; rating 2.5%FS Offset voltage - temperature characteristics (%FS) 60 1-<2> Offset voltage - temperature characteristics 0 980.7/2 {5} kpa {kgf/cm2} 4 4 Sensitivity - temperature characteristics (%FS) 1. Characteristics data 1-<1> Output characteristics 3 2 1 0 -1 -2 0 +32 980.7 {10} Rated pressure 30 +86 60 +140 Temperature (C F) 3 2 1 0 -1 -2 0 +32 30 +86 60 +140 Temperature (C F) 2. Pressure cycle range (0 to rated pressure) Tested sample: ADP41913, temperature: 100C 212F, No. of cycle: 1x106 2-<2> Output span voltage range 3 3 2 2 Output span voltage range (%FS) Offset voltage range (%FS) 2-<1> Offset voltage range 1 0 -1 -2 -3 0 5x105 Pressure cycle (cycle) 24 1x106 Even after testing for 1 million times, the variations in the offset voltage and output span voltage are minimal. 1 0 -1 -2 -3 0 5x105 Pressure cycle (cycle) 1x106 PS PRESSURE SENSOR 2002.10.23 7:58 PM Page 25 PS (ADP4) 3. Evaluation test Tested item Storage at high temperature Storage at low temperature Environmental characteristics Tested condition Temperature: Left in a 120C 248F constant temperature bath Time: 1,000 hrs. Temperature: Left in a -40C -40F constant temperature bath Time: 1,000 hrs. Temperature/humidity: Left at 40C 104F, 90% RH Time: 1,000 hrs. Temperature: -40C to 120C -40F to 248F 1 cycle: 30 min. Times of cycle: 100 Temperature/humidity: 40C 104F, 90% RH Operation times: 106, rated voltage applied Double amplitude: 1.5 mm .059 inch Vibration: 10 to 55 Hz Applied vibration direction: X, Y, Z 3 directions Times: 2 hrs each Dropping height: 75 cm 29.528 inch Times: 2 times Pulling strength: 9.8 N {1 kgf}, 10 sec. Bending strength: 4.9 N {0.5 kgf}, left and right 90 1 time Temperature: 230C 446F Time: 5 sec. Temperature: 260C 500F Time: 10 sec. Humidity Temperature cycle Endurance characteristics High temperature/high humidity operation Vibration resistance Mechanical characteristics Dropping resistance Terminal strength Soldered in DIP soldering bath Soldering Resistance Temperature Result Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Note: For details other than listed above, please consult us. General tolerance: 0.3 .012 mm inch DIMENSIONS 1. Terminal direction: Direction opposite the pressure inlet derection ADP41mmm 2. Terminal direction: Pressure inlet direction ADP42mmm 7.2 .283 7.2 .283 Pressure inlet hole 1.1 dia. .043 dia. Pressure inlet hole 1.1 dia. .043 dia. 7.2 .283 7.2 .283 0.25 4 dia. .157 dia. 2.5 .010 .098 0 2.5 -0.1 dia. 0 .098 -.004 dia. 2.5 .010 .098 0.1 8.2Max .323Max 0.5 .004 .020 .2 8 R0 .00 R 4 5 .157 .197 4 5 .157 .197 3.7 .164 3.5 .138 2.5 2 .004 .098 .010 0.25 0.1 .010 .004 1.5 Recommended PC board pattern (BOTTOM VIEW) 3 Atmospheric Pressure inlet hole 6 5 1 2 6 5 Atmospheric Pressure inlet hole 9.5 .059 .374 JAPAN 1 .020 0.25 .2 R0 08 R.0 3 8.2Max .323Max JAPAN 0.5 0.25 2.5 .010 .098 0 2.5 -0.1 dia. 0 .098 -.004 dia. 0.1 0.25.004 .010 3.5 .138 4.6 .181 0.1 9.5 1.5 .374 .059 4 dia. .157 dia. 0.25 4 Recommended PC board pattern (BOTTOM VIEW) 6-0.9 dia. 6-.035 dia. 4 6-0.9 dia. 6-.035 dia. 5d .197 ia. dia. 7.5 .295 Tolerance: 0.1 .004 7.5 .295 Tolerance: 0.1 .004 2.5 .098 2.5 .098 2.5 .098 2.5 .098 3. Terminal connection diagram +Output R1 R2 +Input -Input R3 R4 -Output Terminal No. Name 1 Power supply (+) 2 Output (+) 3 Power supply (-) 4 Power supply (-) 5 Output (-) 6 No connection Note: Leave terminal 6 unconnected. 25 PS PRESSURE SENSOR 2002.10.23 7:58 PM Page 26 PS (ADP4) NOTES 1. Mounting Use lands on the printed-circuit boards to which the sensor can be securely fixed. 2. Soldering 1) Due to its small size, the thermal capacity of the pressure sensor DIP type is low. Therefore, take steps to minimize the effects of external heat. Dip soldering bath: Max. 260C 500F, 5 sec. Soldering iron: 260 to 300C 500 to 572F (30W) within 5 sec. 2) Use a non-corrosive resin type of flux. Since the pressure sensor DIP type is exposed to the atmosphere, do not allow flux to enter inside. 3. Cleaning 1) Since the pressure sensor chip is exposed to the atmosphere, do not allow cleaning fluid to enter inside. 2) Avoid ultrasonic cleaning since this may cause breaks or disconnections in the wiring. 4. Environment Consult with us before using or storing the pressure sensor chip in a place exposed to corrosive gases (such as the gases given off by organic solvents, sulfites, hydrogen sulfides, etc.) which will adversely affect the performance of the pressure sensor chip. 5. Quality check under actual loading conditions 1) To assure reliability, check the sensor under actual loading conditions. Avoid any situation that may adversely affect its performance. 2) As for test data, please contact us. 6. Other handling precautions 1) That using the wrong pressure range or mounting method may result in accidents. 2) Air can be used directly as a pressure medium. Consult with us before using a corrosive gas (such as a gas given off by an organic solvent, sulfite or hydrogen sulfide) as the pressure medium. 3) The pressure sensor chip is positioned inside the pressure inlet. Never poke wires or other foreign matter through the pressure inlet since they may damage the chip or block the inlet. Avoid use when the atmospheric pressure inlet is blocked. 4) Leave pin No. 6 unconnected since the pressure sensor chip may be damaged if a voltage is applied to this pin. 5) Use an operating pressure which is within the rated pressure range. Using a pressure beyond this range may cause damage. 6) Since this pressure sensor chip does not have a water-proof construction, consult with us if it is to be used in a location where it may be sprayed with water, etc. 7) Avoid using the pressure sensor chip in an environment where condensation may form. Furthermore, its output may fluctuate if any moisture adhering to it freezes. APPLICATION CIRCUIT DIAGRAM (EXAMPLE) MOUNTING METHOD The pressure sensor is designed to convert a voltage by means of constant current drive and then, if necessary, it amplifies the voltage for use. The circuit shown below is a typical example of a circuit in which the pressure sensor is used. Amplifier circuit unit Constant current circuit unit Pressure sensor The general method for transmitting air pressures differs depending on whether the pressure is low or high. * Checkpoints for use <1> Select a pressure inlet pipe which is sturdy enough to prevent pressure leaks. <2> Fix the pressure inlet pipe securely so as to prevent pressure leaks. <3> Do not block the pressure inlet pipe. 8) The pressure sensor chip is constructed in such a way that its output will fluctuate when it is exposed to light. Especially when pressure is to be applied by means of a transparent tube, take steps to prevent the pressure sensor chip from being exposed to light. 9) Avoid using the pressure sensor chip where it will be susceptible to ultrasonic or other high-frequency vibration. 10) Since static charge can damage the pressure sensor chip, bear in mind the following handling precautions. * When storing the pressure sensor chips, use a conductive material to short the pins or wrap the entire chip in aluminum foil. Plastic containers should not be used to store or transport the chips since they readily become charged. * When using the pressure sensor chips, all the charged articles on the bench surface and the work personnel should be grounded so that any ambient static will be safely discharged. 11) Due to the pressures involved, give due consideration to the securing of the pressure sensor DIP type and to the securing and selection of the inlet tube. Consult us if you have any queries. Methods of transmitting air pressures When the pressure is low (4.9 to 98.1 kPa) Printedcircuit board When the pressure is high (196.1 to 980.7 kPa) Printedcircuit board O-ring Tube Pressure inlet pipe If a tube is used as the pressure inlet pipe, it may become disengaged. Therefore, use a sturdy tube and secure it using O-rings. OP AMP OP AMP OP AMP 12/1/2002 All Rights Reserved, (c) Copyright Matsushita Electric Works, Ltd.