8 7 6 5 4 3 2 VICOR CONFIDENTIAL F 1 REVISIONS THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR HEREWITH IS NOT TO BE REPRODUCED, USED OR DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT THE PERMISSION OF VICOR CORP. REV .590 MAX 1.240 MAX DATE DESCRIPTION APPROVED DPK 4/5/95 RCM 03 REVSD & REDWN PER E950112 4 REVISED PER ECO Request E080622 REJH 03/28/08 EF 5 REVISED PER E100698A 5/19/10 JG KUK F E E .965 MAX .236 D D 1.080 C .031 NOTES: 1. APPROVALS INCLUDE VDE, SEV, DEMKO, SEMKO, NEMKO, SETI, UL, IMQ, OVE. ELECTRICAL CHARACTERISTICS RATED VOLTAGE: 250 VAC, 50/60 Hz CAPACITANCE TOLERANCE: 10% DISSIPATION FACTOR: < 1% MEASURED AT 1 KHZ 3. RoHS COMPLIANT, LEAD FREE PER CST-0001 LATEST REVISION. MAXIMUN PULSE RISE TIME: ACCORDING TO VDE 0565 PART 1 4. DIMENSIONS ARE INCHES ONLY. C 2. LEADS ARE TINNED COPPER WIRE. du/dt 100V / uSEC B DIELECTRIC: POLYESTER-FILM TEST VOLTAGE: (ELECTRODE/ELECTRODE) B DRAWN 1075 V-, 2 SEC. D.P. KELLY (SELF HEALINGS ARE ALLOWED TO OCCUR) INSULATION RESISTANCE: FOR C .33uF A COATING: PLASTIC CAN, EPOXY RESIN SEALED, FLAME RETARDANT 8 7 6 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE INCH [MM] TOLERANCES ARE: DECIMALS ANGLES X.XX [X.X] = 0.01 [0.25] 1 X.XXX [X.XX] = 0.005 [0.127] FINISH THIRD ANGLE PROJECTION DO NOT SCALE DRAWING 5 4 3 SWD 4/95 MATERIAL 15000 MEGOHM MINIMUM VALUE VICOR DATE CAP, FLM, AXIAL 1uF, 10%, 250V SIZE CAGE CODE B 67131 SCALE 2 : 1 DWG NO REV 02573 5 SHEET 1 OF 1 2 1 A