10 December 2014 Page 1 500W Single Output with PFC Function FEATURES Universal AC Input / Active PFC A DC fan is provided voltage / Over-temperature 23.5CFM forced Protections: Short-Circuiting / Over-load / OverAll Using 105C Long-Life Electrolytic Capacitors High Operating temperatures of up to 65C Power "OK" Signal U-Bracket Low Profile: 38mm Active AC Surge Current Limiting 3 Year Warranty SP-500 series Cooling-Free Air Convection for 400w and 500W with 2 Mode - Remoter for ON/OFF Ctrl. Which is Setup by User Remote Voltage Sense High Power Density 6.4w/in^3 Withstands 2G Vibration Testing High Efficiency, Long Life, and High Reliability Environmental Conditions Protection Requirement Input Requirements Output Requirements SPECIFICATION Model Voltage (1) Rated Current Current Range (Convection) Rated Power (10.5CFM Fan) Rated Power (Convection) Rated Power (10.5 CFM Fan) Ripple & Noise (Max) (2) Voltage Adjustment Range Voltage Tolerance (3) Line Regulation Load Regulation Setup, Rise Time Hold Time SP-500-12 12V 42A SP-500-15 15V 33.5A SP-500-24 24V 21A SP-500-48 48V 10.5A 0 ~ 33.3A 0 ~ 26.7A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 42A 0 ~ 33.5A 0 ~ 21A 0 ~ 10.5A 399.6W 400.5W 400.8W 403.2W 504W 502.5W 504W 504W 150 mVp-p 150 mVp-p 150 mVp-p 150 mVp-p 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V 2% 1% 2% Voltage (4) Frequency Efficiency (Typ.) AC Current (max.) Inrush Current (Typ.) Leakage Current Over Load Over Voltage Over Temperature Operating Temperature Operating Humidity Storage Temperature, Humidity Temperature Coefficient Vibration www.autec.com 2% 2% 1% 1% 2% 2% 600ms, 30ms at full load 16ms / 230VAC at full load 2% 1% 2% 90V ~ 264VAC / 127 ~ 370VDC 47Hz ~ 63Hz 90% 90% 90% 91% 6 A / 115VAC 2A / 230VAC 30A / 115VAC 44A / 230VAC < 2mA / 230VAC > 105% rated output power Protection type: constant current limiting, output voltage less than 50% rating DC voltage range after 500ms the unit will shutdown 115% ~ 150% rated output voltage Protection type: latch-off mode 95C With N2 sense by T1 core 5C, 95C With TH1 sense near D26 heat sink 5C -20C ~ +65C (Refer to output load de-rating curve) 20 ~ 90% RH non-condensing - 40 +85 / 10 ~ 95% R.H~ 0.03%/ (0 ~ 50) 10 ~ 500HZ, 2G 10min./ 1 cycle, period for 60 min. Each along X,Y,Z axes Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 10 December 2014 Page 2 Model Safety & EMC (5) Safety Standards Withstand Voltage Isolation Resistance SP-500-15 SP-500-24 I/P -O/P : 4242 DC I/P -FG : 2121 DC 1 minute I/P -O/P,I/P -FG, O/P -FG:100M /500VDC EN55022: 2006 Class B Harmonic Current EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 Connection EN61204-3: 2000, EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A I/P 3P / 9.5mm terminal block with cover, O/P : 8P/9.5mm terminal block with cover Power Ok signal Open Darin. Max 30Vdc / 0.1A Cooling MTBF (MILHDBK-217F) ON/OFF Remote Control Remote Voltage Sense Dimension (W*H*D) Free Air convection for 400W, With23.5CFM Fan for 500W Packing SP-500-48 UL 60950-1, 2nd Edition, TUV EN60950-1 : 2006+A11 Approved EMI Conduction & Radiation EMS Immunity Others SP-500-12 Two modes setup remote ON/OFF see Function Description of J2 Compensates for wire voltage drop 254 x 127 x 38(mm) or 10 x 5 x 1.50(inches) 1.7kg : 12Pcs / 20.4KG NOTES: 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. De-rating may be needed under low input voltages. Please check the de-rating curve for more details. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be reconfirmed that it still meets EMC directives. 6. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition. www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 10 December 2014 Page 3 www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 10 December 2014 Page 4 www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 10 December 2014 Page 5 SP-500-24 Voltage Switching Power (Opern Frame) Watts www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777