Temperature Sensor E52 CSM_E52_DS_E_21_5 A Wide Variety of High-precision Temperature Sensors * Previous models with M3 screw connections have been joined by new models with ferrules to help reduce wiring work. * A Temperature Sensor for Packaging Machines that accurately measures seal temperature has been added. * The type, shape, length, and terminal shape can be selected to match the temperature to be measured, location, and environment. Refer to Safety Precautions for All Temperature Controllers. Ordering Information List of Models (Temperature Sensors) Classifi- Description cation Generalpurpose Models Model and appearance Temperature range (See note 3.) Element type Sheathed E52-P@AY platinum resistance E52-P@C-N thermometer E52-P@B-N -196C to 450C Standard E52-P@C-N platinum resistance thermometer 0C to 450C Sheathed E52-CA@AY thermocou- E52-IC@AY ple E52-CA@B-N E52-IC@B-N 0C to 900C K (CA) J (IC) Pt100 Conductor type Class 3-conduc- B tor system -196C to 450C Protective tubing material SUS316 Exposed 5 lead wires ASTM316L Enclosed terminals Nongrounded type 2 (0.75) SUS316 Enclosed terminals ASTM316L Exposed 9 to lead wires 12 Exposed terminals SUS316 0C to 1,400C R (PR) Low-cost E52-P10AEY platinum reE52-P6DY sistance thermometer E52-P6FY 0C to 250C Pt100 Low-cost E52-CA@ASY thermocou- E52-IC@ASY ple E52-CA1DY E52-IC1DY 0C to 400C K (CA) J (IC) 13 -50C to 250C 2 (0.25) 3-conduc- B tor system Exposed terminals 14 Enclosed terminals 15 JIS ceramic Enclosed JIS special terminals ceramic 16 SUS316 SUS304 Exposed 17 lead wires Non-ground- 2 (0.75) ed type 18 Grounded type 19 20 E52-CA6F-N E52-CA6F-N-25 E52-IC6F-N E52-CA6D-N E52-CA6D-N-25 E52-IC6D-N E52-CA10AE-N E52-IC10AE-N 7 Enclosed terminals Standard E52-CA@B-N thermocou- E52-IC@B-N ple E52-CA@C-N E52-IC@C-N Low-cost Models 6 Exposed terminals E52-CA@C-N E52-IC@C-N E52-PR@C-N Terminal Page type Non-grounded type Note: 1. Exclusive models are provided on the following page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing. 1 E52 Classifi- Description cation Exclusive Models Model and appearance Temperature range (See note 3.) Element type Bayonet E52-CA2GVY spring for E52-IC2GVY molding machines 0C to 350C K (CA) J (IC) Crimping terminals 0C to 300C E52-CA1GTY E52-IC1GTY Used for E52-P2GSY measuring surface temperatures -50C to 250C Used for room temperature measurement -50C to 60C Conductor type Class Grounded 2 (0.75) type Protective tubing material SUS304 Terminal Page type Exposed 22 lead wires --- 3-conduc- B tor system SUS304 23 0C to 900C K (CA) Two nongrounded types ASTM316L 28 E52-P20AY-7 -196C to 250C Two 3B conductor systems E52-P20C-N-7 -200C to 450C E52-P10GPY 0C to 70C E52-P5AY-40 -50C to 180C Corrosionresistant model E52-P20AY-1 -80C to 180C E52-CA20AY-1 0C to 180C K (CA) Nongrounded type Siliconecovered lead wires E52-CA1DY-40 0C to 300C Grounded type E52-CA1GTY-14 0C to 200C E52-P10GRY Double-ele- E52-CA20AY-7 ment model Waterproof model Pt100 Pt100 2 (0.75) Enclosed terminals 3-conductor system SUS304 29 Exposed 23 lead wires Fluororesin tubing 25 SUS304 30 2 (0.75) --- Explosion- E52-P@@C-N-6 proof model --- Pt100 3-conduc- B tor system E52-CA@@C-N-6 --- K (CA) Nongrounded type ASTM316L Enclosed terminals 26 2 (0.75) E52-CAAY Special Sheathed models for thermocou- D=1 S packaging ple machines 0C to 650C K (CA) Grounded 2 (0.75) type ASTM316L Exposed 31 lead wires to 33 Thermistors -50C to 300C Element- 1 interchangeable thermistor SUS304 Exposed 35 lead wires E52-THE5A E52-THE6F E52-THE6D Thermistor Note: 1. General-purpose models and low-cost models are provided on the previous page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing. Use the temperature sensors with ferrule from the list on the next page. 2 E52 List of Models (Temperature Sensors with ferrule) Classification Generalpurpose Models Low-cost Models Exclusive Models Description Model and appearance Tempera- Element type ture range (See note 3.) Conductor type Class Protective Terminal Page tubing type material Sheathed platinum resistance thermometer E52-P@AF -196C to 450C Sheathed thermocouple E52-CA@AF 0C to 900C K (CA) Nongrounded type Low-cost platinum resistance thermometer Low-cost thermocouple E52-P10AEF 0C to 250C Pt100 E52-P6DF 3-conduc- B tor system E52-P6FF -50C to 250C E52-CA1DF 0C to 400C K (CA) Grounded 2 (0.75) type 42 Bayonet spring E52-CA2GVF for molding machines 0C to 350C K (CA) Grounded 2 (0.75) SUS304 type 43 Crimping terminals 0C to 300C E52-CA1GTF Used for E52-P2GSF measuring surface temperatures Used for room E52-P10GRF temperature measurement Waterproof model -50C to 250C 3-conduc- B tor system SUS316 Exposed 37 lead wires 2 (0.75) ASTM316L SUS316 E52-P10GPF 0C to 70C E52-P5AF-40 -50C to 180C 39 to 40 41 SUS304 --- Pt100 3-conduc- B tor system SUS304 -50C to 60C Silicone-covE52-CA1DF-40 ered lead wires Special Sheathed models for thermocouple packaging machines Pt100 44 Fluororesin tubing 0C to 300C K (CA) E52-CA1GTF-14 0C to 200C E52-CA@AF D=1 S@ 0C to 650C K (CA) Grounded 2 (0.75) SUS304 type 45 46 --- Grounded 2 (0.75) ASTM316L type 47 to 48 Note: 1. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 2. The temperature range varies with the material, thickness, construction, and element type of the protective tubing. Accessories It is recommended that the following accessories be used for mounting Temperature Sensors. Accessory Compression Fitting Temperature range 600C max. Mounting example Mounting with Compression Fitting Page 49 Terminal box Compression Fitting PT screw Welding Loose Flange 400C max. Mounting with Loose Flange Loose Flange Mounting screw Protective tubing Terminal box Protective tubing Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. Note: 1. Use the Loose Flange in normal atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400C max. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. 3 E52 General-purpose Models Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Platinum Resistance Thermometers E52-@@@ D=@@@M 1 2 3 4 5 6 1. Element type P: Pt100 2. Protective tubing length (L) Specify the length in centimeters within the following range: Unit (cm) E52-@@AY Diameter (D) Length (L) 3.2 7 to 100 4.8 10 to 600 6.4 13 to 1,300 4. Diameter 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) E52-@@AY and E52-@@C-N only 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) E52-@@AY and E52-@@C-N only 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) E52-@@AY and E52-@@C-N only 8: 8-mm dia. (Protective tubing construction: Sheathed) E52-@@B-N and E52-@@C-N only 10: 10-mm dia. (Protective tubing construction: Standard) E52-@@C-N only 5. Heat resistance E52-@@B-N Code Diameter (D) 8 Length (L) Diameter (D) Vinyl-covered NETU 0C to 180C Sleeve: 0C to 100C Glass-wool-covered, externally shielded with stainless Length (L) 3.2 12 to 100 4.8 15 to 600 6.4 18 to 1,300 8 21 to 100 10 26 to 100 Lead type -20C to 70C Sleeve: 0C to 70C 20 to 100 E52-@@C-N Temperature range --- Specify for E52-@@AY model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@AY only: Range: 0.5, 1 to 100 m 3. Terminal AY: Exposed lead wires (Y-type crimp terminal for M3.5) B-N: Exposed terminals C-N: Enclosed terminals Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42AY D=4.8 NETU 10M Sheathed Platinum Resistance Thermometers Refer to Model Number Legend above for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 (E52-P@AY) ASTM316L (E52-P@B-N, E52-P@C-N) Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia Conductor type 3-conductor system Temperature range -196C to 450C (in dry air) 4 E52 Exposed-lead Models E52-P@AY Dimensions Marking tube (Red) Shrinkable tube (Black) Sleeve (SUS304) Sheath (SUS316) Swage Marking tube (White) Unit (mm) Crimping terminal Y type for M3.5 White Product Label d l 3.2 dia. 8 40 4.8 dia. 8 40 6.4 dia. 8 40 D Red Red (A) Lead wire Lead Wire White (B) D0.05 8 dia. Black (B) (30) L3% 40 M4% (80) 8510 * Standard (-20C to 70C): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0C and 70C. * Heat Resistive (0C to 180C): Fully glass-wool-covered with thirty 0.12-dia. conductors (0.3 mm thick) externally shielded with stainless steel, 4 mm in outer dia. The sleeve resists a temperature range between 0C and 100C. * Lead Wire Length (M): 1, 2, 4, or 8 m Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 4.8 dia. 20 35 50 Lead wire type 20 35 50 2 4 8 Model Standard E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 1M 2M 4M 8M Heat resistive E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 1M 2M 4M 8M Heat resistive E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 1M 2M 4M 8M Heat resistive E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 1M 2M 4M 8M Heat resistive E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 1M 2M 4M 8M Heat resistive E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P50AY D=4.8 1M E52-P50AY D=4.8 NETU 1M Heat resistive 6.4 dia. Lead wire length M (m) 1 E52-P50AY D=4.8 2M E52-P50AY D=4.8 NETU 2M E52-P50AY D=4.8 4M E52-P50AY D=4.8 NETU 4M E52-P50AY D=4.8 8M E52-P50AY D=4.8 NETU 8M Standard E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 1M 2M 4M 8M Heat resistive E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 1M 2M 4M 8M Heat resistive E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 1M 2M 4M 8M Heat resistive E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 NETU 1M NETU 2M NETU 4M NETU 8M 5 E52 Enclosed-terminal Models E52-P@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (66) Product label Cap Socket (SUS304) Sheath (ASTM316L) Swage 58 dia. D0.05 (66) Terminal box (15) Chain 40 G 3 8 L-353% Use wiring terminals that fit M3 screws. (Packing internal diameter : 6.5 dia) Terminal box: The permissible temperature is 0C to 90C. Note: 1. The terminals in the cap indicate polarity (A, B, b). 2. The length L is in centimeters, but "35" is 35 millimeters. Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L - 35 = 350 - 35 = 315 mm. Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing length L (cm) Enclosed-terminal Models Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model 20 E52-P20C-N D=3.2 E52-P20C-N D=4.8 E52-P20C-N D=6.4 E52-P20C-N D=8 35 E52-P35C-N D=3.2 E52-P35C-N D=4.8 E52-P35C-N D=6.4 E52-P35C-N D=8 50 E52-P50C-N D=3.2 E52-P50C-N D=4.8 E52-P50C-N D=6.4 E52-P50C-N D=8 75 --- E52-P75C-N D=4.8 E52-P75C-N D=6.4 --- Exposed-terminal Models E52-P@B-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Model Information Terminal box Socket (SUS304) 5.6 Product label Swage b B A Sheath (ASTM316L) 80.05 dia. Custom-made models are available on request. Refer to page 4 for details Terminal type 19.2 45 17 17.6 19 dia. 21.5 3xM3 30.5 42.5 (51) (15) L-403% Terminal box: The permissible temperature is 0C to 100C. Exposedterminal Models Protective Protective tubing diameter D (mm) tubing length 8 dia. L (cm) Model 20 E52-P20B-N D=8 35 E52-P35B-N D=8 50 E52-P50B-N D=8 Note: The length L is in centimeters, but "40" is 40 millimeters. Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L - 40 = 350 - 40 = 310 mm. 6 E52 Standard Platinum Resistance Thermometers Refer to Model Number Legend on page 4 for the Pt100. Specifications Element type Pt100 Class JIS class B Protective tubing material SUS316 Conductor type 3-conductor system Temperature range 0C to 450C (in dry air) Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result. Enclosed-terminal Models E52-P@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (92) Product label Cap Socket (SUS304) Full-circled Welding 82 dia. Protective tubing (SUS316) 100.3 dia. (86) 38 dia. Chain G1 2 (Packing internal diameter : 9 dia.) Terminal box (5) L-503% 53 Note: 1. The length L is in centimeters, but "50" is 50 millimeters. Therefore, for the E52-P75C-N: L = 75 (cm), the protective tubing length L - 50 = 750 - 50 = 700 mm. Terminal box: The permissible temperature is 0C to 90C. Note: The terminals in the cap indicate polarity (A, B, B). Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. Model Enclosed-terminal Models 35 E52-P35C-N D=10 50 E52-P50C-N D=10 75 E52-P75C-N D=10 100 E52-P100C-N D=10 7 E52 Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Thermocouples E52-@@@ D=@@@M@ 1 2 3 4 5 6 7 1. Element type CA:K IC: J PR:R 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) 4. Diameter Specify the protective tubing material according to the table. Code Diameter Protective tubing (D) construction Protective tubing material 1 1 mm Sheathed ASTM316L 1.6 1.6 mm Sheathed ASTM316L E52-@@AY (Exposed-lead Model) 3.2 3.2 mm Sheathed ASTM316L Diameter (D) 4.8 4.8 mm Sheathed ASTM316L 6.4 6.4 mm Sheathed ASTM316L 8 8 mm Sheathed ASTM316L 10 10 mm Standard SUS316, SUS310S 12 12 mm Standard SUS316, SUS310S 15 15 mm Standard Length (L) 1 2 to 200 1.6 3 to 500 3.2 5 to 2,000 4.8 8 to 2,300 6.4 10 to 1,200 8 12 to 1,000 E52-@@B-N and E52-@@C-N (except E52-PR@C-N) Diameter (D) Length (L) 3.2 11 to 2,000 4.8 14 to 2,300 6.4 16 to 1,200 8.0 18 to 1,000 10 21 to 126 12 24 to 126 15 29 to 156 22 39 to 206 E52-PR@C-N Diameter (D) 15 SUS316, SUS310S PT1, PT0 (E52-PR) 22 22 mm Standard SUS316, SUS310S 5. Heat resistance Specify this item for the exposed-lead models only. Code Temperature range Lead type --- -20C to 70C Sleeve: 0C to 70C Vinyl-covered NETU 0C to 150C Sleeve: 0C to 100C Glass-wool-covered with external shield of stainless 6. Lead length (M) Specify the length in meters in the following range for the E52@@AY only. Range: 1 to 100 m 7. Protective tubing material Length (L) Code 50, 75, 100 3. Terminal AY: Exposed lead wires (Y-type crimp terminal for M3.5) (element type: K, J) B-N: Exposed terminals (element type: K, J) C-N: Enclosed terminals (element type: K, J, R) Protective tubing material Element type --- ASTM316L K, J SUS310S SUS310S K, D = 10 to 22 PT1 JIS ceramic Cat.1 R PT0 JIS special ceramic R Examples Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA42AY D=4.8 NETU 10M Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2 E52-IC36C-N D=3.2 8 E52 Sheathed Thermocouples Specifications Permissible Temperature in Dry Air D Element type K (CA), J(IC) Class JIS class 2 (0.75) Thermal contact Non-grounded type Sheath material CA: ASTM316L Element wire K (CA) ASTM316L IC: ASTM316L J (IC) ASTM316L 1 dia. 650C 450C 1.6 dia. 650C 450C 3.2 dia. 750C 650C 4.8 dia. 800C 750C 6.4 dia. 800C 750C 8.0 dia. 900C 750C Note: For details on the permissible temperature, refer to page D-5 of Introduction of Temperature Controllers (Cat. No. H900). Exposed-lead Models E52-CA@AY Dimensions Sleeve (SUS304) Sheath (ASTM316L) Swage Lead wire Unit (mm) Crimping terminal Y type for M3.5 Shrinkable tube (CA:Blue, IC:Yellow) Red (+) Product label D0.05 305 M4% 55 l 8 55 1.6 dia. 8 55 3.2 dia. 8 55 4.8 dia. 8 55 6.4 dia. 11 55 8 dia. 11 55 D d L3% d 1 dia. Transparent Marking tube (White) (80) 9010 White (-) Note: 1. Lead Wire (Compensating Conductor) * Standard (-20C to 70C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 2.4 x 4.1. * Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.8 x 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between -20C and 70C for standard models and 0C and 100C for heat-resistive models. Permissible Temperature in Dry Air D Element wire K (CA) ASTM316L 1 dia. 650C 1.6 dia. 650C 3.2 dia. 750C 4.8 dia. 800C 6.4 dia. 800C 8.0 dia. 900C K (CA) Model Information (E52-CA@AY) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1 dia. 15 20 35 Standard E52-CA15AY D=1 1M E52-CA15AY D=1 2M E52-CA15AY D=1 4M E52-CA15AY D=1 8M Heat resistive E52-CA15AY D=1 NETU 1M E52-CA15AY D=1 NETU 2M E52-CA15AY D=1 NETU 4M E52-CA15AY D=1 NETU 8M Standard E52-CA20AY D=1 1M E52-CA20AY D=1 2M E52-CA20AY D=1 4M E52-CA20AY D=1 8M Heat resistive E52-CA20AY D=1 NETU 1M E52-CA20AY D=1 NETU 2M E52-CA20AY D=1 NETU 4M E52-CA20AY D=1 NETU 8M Standard E52-CA35AY D=1 1M E52-CA35AY D=1 2M E52-CA35AY D=1 4M E52-CA35AY D=1 8M Heat resistive E52-CA35AY D=1 NETU 1M E52-CA35AY D=1 NETU 2M E52-CA35AY D=1 NETU 4M E52-CA35AY D=1 NETU 8M 9 E52 Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1.6 dia. 15 20 35 3.2 dia. 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 Standard E52-CA15AY D=1.6 1M E52-CA15AY D=1.6 2M E52-CA15AY D=1.6 4M E52-CA15AY D=1.6 8M Heat resistive E52-CA15AY D=1.6 NETU 1M E52-CA15AY D=1.6 NETU 2M E52-CA15AY D=1.6 NETU 4M E52-CA15AY D=1.6 NETU 8M Standard E52-CA20AY D=1.6 1M E52-CA20AY D=1.6 2M E52-CA20AY D=1.6 4M E52-CA20AY D=1.6 8M Heat resistive E52-CA20AY D=1.6 NETU 1M E52-CA20AY D=1.6 NETU 2M E52-CA20AY D=1.6 NETU 4M E52-CA20AY D=1.6 NETU 8M Standard E52-CA35AY D=1.6 1M E52-CA35AY D=1.6 2M E52-CA35AY D=1.6 4M E52-CA35AY D=1.6 8M Heat resistive E52-CA35AY D=1.6 NETU 1M E52-CA35AY D=1.6 NETU 2M E52-CA35AY D=1.6 NETU 4M E52-CA35AY D=1.6 NETU 8M Standard E52-CA15AY D=3.2 1M E52-CA15AY D=3.2 2M E52-CA15AY D=3.2 4M E52-CA15AY D=3.2 8M Heat resistive E52-CA15AY D=3.2 NETU 1M E52-CA15AY D=3.2 NETU 2M E52-CA15AY D=3.2 NETU 4M E52-CA15AY D=3.2 NETU 8M Standard E52-CA20AY D=3.2 1M E52-CA20AY D=3.2 2M E52-CA20AY D=3.2 4M E52-CA20AY D=3.2 8M Heat resistive E52-CA20AY D=3.2 NETU 1M E52-CA20AY D=3.2 NETU 2M E52-CA20AY D=3.2 NETU 4M E52-CA20AY D=3.2 NETU 8M Standard E52-CA35AY D=3.2 1M E52-CA35AY D=3.2 2M E52-CA35AY D=3.2 4M E52-CA35AY D=3.2 8M Heat resistive E52-CA35AY D=3.2 NETU 1M E52-CA35AY D=3.2 NETU 2M E52-CA35AY D=3.2 NETU 4M E52-CA35AY D=3.2 NETU 8M Standard E52-CA50AY D=3.2 1M E52-CA50AY D=3.2 2M E52-CA50AY D=3.2 4M E52-CA50AY D=3.2 8M Heat resistive E52-CA50AY D=3.2 NETU 1M E52-CA50AY D=3.2 NETU 2M E52-CA50AY D=3.2 NETU 4M E52-CA50AY D=3.2 NETU 8M Standard E52-CA20AY D=4.8 1M E52-CA20AY D=4.8 2M E52-CA20AY D=4.8 4M E52-CA20AY D=4.8 8M Heat resistive E52-CA20AY D=4.8 NETU 1M E52-CA20AY D=4.8 NETU 2M E52-CA20AY D=4.8 NETU 4M E52-CA20AY D=4.8 NETU 8M Standard E52-CA35AY D=4.8 1M E52-CA35AY D=4.8 2M E52-CA35AY D=4.8 4M E52-CA35AY D=4.8 8M Heat resistive E52-CA35AY D=4.8 NETU 1M E52-CA35AY D=4.8 NETU 2M E52-CA35AY D=4.8 NETU 4M E52-CA35AY D=4.8 NETU 8M Standard E52-CA50AY D=4.8 1M E52-CA50AY D=4.8 2M E52-CA50AY D=4.8 4M E52-CA50AY D=4.8 8M Heat resistive E52-CA50AY D=4.8 NETU 1M E52-CA50AY D=4.8 NETU 2M E52-CA50AY D=4.8 NETU 4M E52-CA50AY D=4.8 NETU 8M Standard E52-CA20AY D=6.4 1M E52-CA20AY D=6.4 2M E52-CA20AY D=6.4 4M E52-CA20AY D=6.4 8M Heat resistive E52-CA20AY D=6.4 NETU 1M E52-CA20AY D=6.4 NETU 2M E52-CA20AY D=6.4 NETU 4M E52-CA20AY D=6.4 NETU 8M Standard E52-CA35AY D=6.4 1M E52-CA35AY D=6.4 2M E52-CA35AY D=6.4 4M E52-CA35AY D=6.4 8M Heat resistive E52-CA35AY D=6.4 NETU 1M E52-CA35AY D=6.4 NETU 2M E52-CA35AY D=6.4 NETU 4M E52-CA35AY D=6.4 NETU 8M Standard E52-CA50AY D=6.4 1M E52-CA50AY D=6.4 2M E52-CA50AY D=6.4 4M E52-CA50AY D=6.4 8M Heat resistive E52-CA50AY D=6.4 NETU 1M E52-CA50AY D=6.4 NETU 2M E52-CA50AY D=6.4 NETU 4M E52-CA50AY D=6.4 NETU 8M Standard E52-CA20AY D=8 1M E52-CA20AY D=8 2M E52-CA20AY D=8 4M E52-CA20AY D=8 8M Heat resistive E52-CA20AY D=8 NETU 1M E52-CA20AY D=8 NETU 2M E52-CA20AY D=8 NETU 4M E52-CA20AY D=8 NETU 8M Standard E52-CA35AY D=8 1M E52-CA35AY D=8 2M E52-CA35AY D=8 4M E52-CA35AY D=8 8M Heat resistive E52-CA35AY D=8 NETU 1M E52-CA35AY D=8 NETU 2M E52-CA35AY D=8 NETU 4M E52-CA35AY D=8 NETU 8M Standard E52-CA50AY D=8 1M E52-CA50AY D=8 2M E52-CA50AY D=8 4M E52-CA50AY D=8 8M Heat resistive E52-CA50AY D=8 NETU 1M E52-CA50AY D=8 NETU 2M E52-CA50AY D=8 NETU 4M E52-CA50AY D=8 NETU 8M 10 E52 Exposed-lead Models E52-IC@AY Dimensions Sleeve (SUS304) Sheath (ASTM316L) Product label Swage Red (+) d 305 L3% 55 M4% Unit (mm) (80) 9010 White (-) Note: 1. Lead Wire (Compensating Conductor) * Standard (-20C to 70C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 2.4 x 4.1. * Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.8 x 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between -20C and 70C for standard models and 0C and 100C for heat-resistive models. Permissible Temperature in Dry Air d l 1 dia. 8 55 1.6 dia. 8 55 3.2 dia. 8 55 4.8 dia. 8 55 6.4 dia. 11 55 8 dia. 11 55 D Transparent Marking tube (White) Lead wire D0.05 Crimping terminal Y type for M3.5 Shrinkable tube (CA:Blue, IC:Yellow) D Element wire J (IC) ASTM316L 1 dia. 450C 1.6 dia. 450C 3.2 dia. 650C 4.8 dia. 750C 6.4 dia. 750C 8.0 dia. 750C J (IC) Model Information (E52-IC@AY) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Terminal type Protective tubing diameter D (mm) Exposed-lead 1 dia. Models Protective tubing length L (cm) 15 20 35 1.6 dia. 15 20 35 Lead wire type Lead wire length M (m) 1 2 4 Model Standard E52-IC15AY D=1 1M E52-IC15AY D=1 2M E52-IC15AY D=1 4M Heat resistive E52-IC15AY D=1 NETU 1M E52-IC15AY D=1 NETU 2M E52-IC15AY D=1 NETU 4M Standard E52-IC20AY D=1 1M E52-IC20AY D=1 2M E52-IC20AY D=1 4M Heat resistive E52-IC20AY D=1 NETU 1M E52-IC20AY D=1 NETU 2M E52-IC20AY D=1 NETU 4M Standard E52-IC35AY D=1 1M E52-IC35AY D=1 2M E52-IC35AY D=1 4M Heat resistive E52-IC35AY D=1 NETU 1M E52-IC35AY D=1 NETU 2M E52-IC35AY D=1 NETU 4M Standard E52-IC15AY D=1.6 1M E52-IC15AY D=1.6 2M E52-IC15AY D=1.6 4M Heat resistive E52-IC15AY D=1.6 NETU 1M E52-IC15AY D=1.6 NETU 2M E52-IC15AY D=1.6 NETU 4M Standard E52-IC20AY D=1.6 1M E52-IC20AY D=1.6 2M E52-IC20AY D=1.6 4M Heat resistive E52-IC20AY D=1.6 NETU 1M E52-IC20AY D=1.6 NETU 2M E52-IC20AY D=1.6 NETU 4M Standard E52-IC35AY D=1.6 1M E52-IC35AY D=1.6 2M E52-IC35AY D=1.6 4M Heat resistive E52-IC35AY D=1.6 NETU 1M E52-IC35AY D=1.6 NETU 2M E52-IC35AY D=1.6 NETU 4M 11 E52 Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 Lead wire type 1 Lead wire length M (m) 2 4 Model Standard E52-IC15AY D=3.2 1M E52-IC15AY D=3.2 2M E52-IC15AY D=3.2 4M Heat resistive E52-IC15AY D=3.2 NETU 1M E52-IC15AY D=3.2 NETU 2M E52-IC15AY D=3.2 NETU 4M Standard E52-IC20AY D=3.2 1M E52-IC20AY D=3.2 2M E52-IC20AY D=3.2 4M Heat resistive E52-IC20AY D=3.2 NETU 1M E52-IC20AY D=3.2 NETU 2M E52-IC20AY D=3.2 NETU 4M Standard E52-IC35AY D=3.2 1M E52-IC35AY D=3.2 2M E52-IC35AY D=3.2 4M Heat resistive E52-IC35AY D=3.2 NETU 1M E52-IC35AY D=3.2 NETU 2M E52-IC35AY D=3.2 NETU 4M Standard E52-IC50AY D=3.2 1M E52-IC50AY D=3.2 2M E52-IC50AY D=3.2 4M Heat resistive E52-IC50AY D=3.2 NETU 1M E52-IC50AY D=3.2 NETU 2M E52-IC50AY D=3.2 NETU 4M Standard E52-IC20AY D=4.8 1M E52-IC20AY D=4.8 2M E52-IC20AY D=4.8 4M Heat resistive E52-IC20AY D=4.8 NETU 1M E52-IC20AY D=4.8 NETU 2M E52-IC20AY D=4.8 NETU 4M Standard E52-IC35AY D=4.8 1M E52-IC35AY D=4.8 2M E52-IC35AY D=4.8 4M Heat resistive E52-IC35AY D=4.8 NETU 1M E52-IC35AY D=4.8 NETU 2M E52-IC35AY D=4.8 NETU 4M Standard E52-IC50AY D=4.8 1M E52-IC50AY D=4.8 2M E52-IC50AY D=4.8 4M Heat resistive E52-IC50AY D=4.8 NETU 1M E52-IC50AY D=4.8 NETU 2M E52-IC50AY D=4.8 NETU 4M Standard E52-IC20AY D=6.4 1M E52-IC20AY D=6.4 2M E52-IC20AY D=6.4 4M Heat resistive E52-IC20AY D=6.4 NETU 1M E52-IC20AY D=6.4 NETU 2M E52-IC20AY D=6.4 NETU 4M Standard E52-IC35AY D=6.4 1M E52-IC35AY D=6.4 2M E52-IC35AY D=6.4 4M Heat resistive E52-IC35AY D=6.4 NETU 1M E52-IC35AY D=6.4 NETU 2M E52-IC35AY D=6.4 NETU 4M Standard E52-IC50AY D=6.4 1M E52-IC50AY D=6.4 2M E52-IC50AY D=6.4 4M Heat resistive E52-IC50AY D=6.4 NETU 1M E52-IC50AY D=6.4 NETU 2M E52-IC50AY D=6.4 NETU 4M Standard E52-IC20AY D=8 1M E52-IC20AY D=8 2M E52-IC20AY D=8 4M Heat resistive E52-IC20AY D=8 NETU 1M E52-IC20AY D=8 NETU 2M E52-IC20AY D=8 NETU 4M Standard E52-IC35AY D=8 1M E52-IC35AY D=8 2M E52-IC35AY D=8 4M Heat resistive E52-IC35AY D=8 NETU 1M E52-IC35AY D=8 NETU 2M E52-IC35AY D=8 NETU 4M Standard E52-IC50AY D=8 1M E52-IC50AY D=8 2M E52-IC50AY D=8 4M Heat resistive E52-IC50AY D=8 NETU 1M E52-IC50AY D=8 NETU 2M E52-IC50AY D=8 NETU 4M 12 E52 Exposed-terminal Models E52-CA@B-N E52-IC@B-N Dimensions Permissible Temperature in Dry Air Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. D Element wire K (CA) ASTM316L Product label Terminal box 2x10 dia. Socket (SUS304) Swage + Sheath (ASTM316L) D0.05 44 18 - 4 2xM3 16 8 3.2 dia. 750C 650C 4.8 dia. 800C 750C 6.4 dia. 800C 750C 8.0 dia. 900C 750C Terminal box: The permissible temperature is 0C to 100C. 3.5 (15) 38.5 (52) 22 dia. J (IC) ASTM316L L-403% Note: The length L is in centimeters, but "40" is 40 millimeters. Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length L - 40 = 500 - 40 = 460 mm. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type K (CA) Exposed-terminal Models J (IC) Exposed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model 20 E52-CA20B-N D=3.2 E52-CA20B-N D=4.8 E52-CA20B-N D=6.4 --- 35 E52-CA35B-N D=3.2 E52-CA35B-N D=4.8 E52-CA35B-N D=6.4 E52-CA35B-N D=8 50 E52-CA50B-N D=3.2 E52-CA50B-N D=4.8 E52-CA50B-N D=6.4 E52-CA50B-N D=8 75 --- E52-CA75B-N D=4.8 E52-CA75B-N D=6.4 E52-CA75B-N D=8 20 E52-IC20B-N D=3.2 E52-IC20B-N D=4.8 E52-IC20B-N D=6.4 --- 35 E52-IC35B-N D=3.2 E52-IC35B-N D=4.8 E52-IC35B-N D=6.4 E52-IC35B-N D=8 50 E52-IC50B-N D=3.2 E52-IC50B-N D=4.8 E52-IC50B-N D=6.4 E52-IC50B-N D=8 75 --- E52-IC75B-N D=4.8 E52-IC75B-N D=6.4 E52-IC75B-N D=8 Enclosed-terminal Models E52-CA@C-N E52-IC@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (66) Permissible Temperature in Dry Air D Element wire Product label K (CA) ASTM316L Cap Socket (SUS304) Swage 58 dia. Sheath (ASTM316L) D0.05 (66) (15) Chain Terminal box 3.2 dia. 750C 650C 4.8 dia. 800C 750C 6.4 dia. 800C 750C 8.0 dia. 900C 750C Terminal box: The permissible temperature is 0C to 90C. L-403% 40 G3 8 (Packing internal diameter 6.5 dia.) J (IC) ASTM316L Use wiring terminals that fit M3 screws. Note: The terminals in the cap indicate polarity (+ or -). Note: The length L is in centimeters, but "40" is 40 millimeters. Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length L - 40 = 350 - 40 = 310 mm. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model 20 E52-CA20C-N D=3.2 E52-CA20C-N D=4.8 E52-CA20C-N D=6.4 --- 35 E52-CA35C-N D=3.2 E52-CA35C-N D=4.8 E52-CA35C-N D=6.4 E52-CA35C-N D=8 50 E52-CA50C-N D=3.2 E52-CA50C-N D=4.8 E52-CA50C-N D=6.4 E52-CA50C-N D=8 75 --- E52-CA75C-N D=4.8 E52-CA75C-N D=6.4 E52-CA75C-N D=8 20 E52-IC20C-N D=3.2 E52-IC20C-N D=4.8 E52-IC20C-N D=6.4 --- 35 E52-IC35C-N D=3.2 E52-IC35C-N D=4.8 E52-IC35C-N D=6.4 E52-IC35C-N D=8 50 E52-IC50C-N D=3.2 E52-IC50C-N D=4.8 E52-IC50C-N D=6.4 E52-IC50C-N D=8 75 --- E52-IC75C-N D=4.8 E52-IC75C-N D=6.4 E52-IC75C-N D=8 13 E52 Standard Thermocouples Specifications Permissible Temperature in Dry Air (See note.) D Element wire K (CA), J(IC), R(PR) Class K (CA), J (IC) JIS class 2 (0.75) Protective tubing material J (IC) SUS316 R(PR), JIS class 2 (0.25) 10 dia. 750C 450C K (CA) SUS316 12 dia. 850C 500C J (IC) 15 dia. 900C 550C 22 dia. 900C 600C SUS316 R (See JIS ceramic cat. 1 (PT1) note.) JIS special ceramic (PT0) Thermal contact Element wire K (CA) SUS316 Note: For details on the permissible temperature, refer to Technical Guide for Temperature Sensors. Non-grounded type Note: Specify PT1 or PT0 if the element is R. D Element wire R 15 dia. 0C to 1,400C Exposed-terminal Models E52-CA@B-N E52-IC@B-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 25.5 9.6 25 Product label Terminal box 2x12 dia. Socket (SUS304) 18 Protective tubing (SUS316 or SUS310S) - 70 30.8 + 3.8 18 D Full-circled welding 2xM4 30 dia. 34.5 5 8 (5) 8 49.5 L-503% (65.5) Terminal box: The permissible temperature is 0C to 100C. Note: The length L is in centimeters, but "50" is 50 millimeters. Therefore, for the E52-CA75B-N: L = 75 (cm), the protective tubing length L - 50 = 750 - 50 = 700 mm. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 750C 450C 12 dia. 850C 500C 15 dia. 850C 550C 22 dia. 900C 600C Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type K (CA) J (IC) Exposed-terminal Models Exposed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model 35 E52-CA35B-N D=10 E52-CA35B-N D=12 E52-CA35B-N D=15 --- 50 E52-CA50B-N D=10 E52-CA50B-N D=12 E52-CA50B-N D=15 E52-CA50B-N D=22 75 E52-CA75B-N D=10 E52-CA75B-N D=12 E52-CA75B-N D=15 E52-CA75B-N D=22 100 E52-CA100B-N D=10 E52-CA100B-N D=12 E52-CA100B-N D=15 E52-CA100B-N D=22 35 E52-IC35B-N D=10 E52-IC35B-N D=12 E52-IC35B-N D=15 --- 50 E52-IC50B-N D=10 E52-IC50B-N D=12 E52-IC50B-N D=15 E52-IC50B-N D=22 75 E52-IC75B-N D=10 E52-IC75B-N D=12 E52-IC75B-N D=15 E52-IC75B-N D=22 100 E52-IC100B-N D=10 E52-IC100B-N D=12 E52-IC100B-N D=15 E52-IC100B-N D=22 14 E52 Enclosed-terminal Models E52-CA@C-N E52-IC@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (92) Cap Product label 82 dia. Socket (SUS304) Full-circled Welding Protective tubing (SUS316 or SUS310S) D (86) 38 dia. Terminal box (5) Chain G1 2 L-503% 53 (Packing internal diameter : 9 dia.) Note: The length L is in centimeters, but "50" is 50 millimeters. Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L - 50 = 500 - 50 = 450 mm. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 0 to 750C 0 to 450C 12 dia. 0 to 850C 0 to 500C 15 dia. 0 to 850C 0 to 550C 22 dia. 0 to 900C 0 to 600C Terminal box: The permissible temperature is 0C to 90C. Note: The terminals in the cap indicate polarity (+ or -). Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Element type Terminal type K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model 35 E52-CA35C-N D=10 E52-CA35C-N D=12 E52-CA35C-N D=15 --- 50 E52-CA50C-N D=10 E52-CA50C-N D=12 E52-CA50C-N D=15 E52-CA50C-N D=22 75 E52-CA75C-N D=10 E52-CA75C-N D=12 E52-CA75C-N D=15 E52-CA75C-N D=22 100 E52-CA100C-N D=10 E52-CA100C-N D=12 E52-CA100C-N D=15 E52-CA100C-N D=22 35 E52-IC35C-N D=10 E52-IC35C-N D=12 E52-IC35C-N D=15 50 E52-IC50C-N D=10 E52-IC50C-N D=12 E52-IC50C-N D=15 E52-IC50C-N D=22 75 E52-IC75C-N D=10 E52-IC75C-N D=12 E52-IC75C-N D=15 --- 100 E52-IC100C-N D=10 E52-IC100C-N D=12 E52-IC100C-N D=15 --- --- 15 E52 Enclosed-terminal Models (High-temperature Use) E52-PR@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (92) Cap Product label Support (SUS304) 82 dia. Ceramic protective tubing (PT0 or PT1) 150.7 dia. (86) * 21.7 dia. 38 dia. Chain * Tubing distortion A dimensions more than 500mm: 0.6% or less A dimensions are less than 500mm: 3mm or less Terminal box (5) G1 2 (100) (Packing internal diameter : 9 dia.) L-1503% A 53 Use wiring terminals that fit M4 screws. Permissible Temperature in Dry Air D Element wire R 15 dia. 0C to 1,400C Terminal box: The permissible temperature is 0C to 90C. Note: The terminals in the cap indicate polarity (+ or -). Note: The length L is in centimeters, but "150" is 150 millimeters. Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing length L - 150 = 750 - 150 = 600 mm. Model Information Element type R (See note 1.) Terminal type Protective tubing length L (cm) Enclosed-ter- 50 minal Models 75 100 R (See note 2.) Enclosed-ter- 50 minal Models 75 100 Standard Protective tubing diameter D (mm) 15 dia. Model E52-PR50C-N D=15 PT1 E52-PR75C-N D=15 PT1 E52-PR100C-N D=15 PT1 E52-PR50C-N D=15 PT0 E52-PR75C-N D=15 PT0 E52-PR100C-N D=15 PT0 Protective tubing material Permissible temperature in dry air Note 1: JIS ceramic Cat.1 (PT1) Mullite, high alumina, etc. 1,500C (See note.) Note 2: JIS special ceramic (PT0) Recrystallized alumina, fused alumina, etc. 1,600C (See note.) Note: The permissible temperature given for the protective tubing is higher than 1,400C, but the permissible temperature of the thermocouple element wire is only 1,400C. Therefore, the protective tubing of the E52-PR@C-N can withstand high temperatures momentarily to the levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures that exceed the permissible temperature for the element wire. 16 E52 Low-cost Models Low-cost Platinum Resistance Thermometers Exposed-lead Models with Screws Specifications E52-P6DY Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Max. detectable temperature 250C Temperature range -50C to 250C Lead wire Fluororesin-covered wire (PFA) with 1.0 outer dia. 7/0.18 -50C to 150C Taper screw for tube R1/8 (SUS304) Full-circled welding (16) Crimping terminal Y type for M3.5 Siliconized shrinkable tube Protective tubing (SUS304) Red Marking tube (Red) Red (A) Lead wire Black (B) 40.4 dia. Black (B) Product label 60.5 100.5 Marking tube (White) White (M-16) (30) 14 65 15 0 -2 M5% Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6DY 1M 2 E52-P6DY 2M 4 E52-P6DY 4M Exposed-lead Models with Flange Specifications E52-P6FY Element wire Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Max. detectable temperature 250C Temperature range -50C to 250C Lead wire Fluororesin-covered wire (PFA) with 1.0 outer dia. 7/0.18 -50C to 150C Crimping terminal Y type for M3.5 Nickel brazing 3x3.5 dia. 120 Red Siliconized shrinkable tube Marking tube (Red) Lead wire Flange (SUS304) 120 40.4 dia. Protective tubing (SUS304) Red (A) Black (B) Black (B) Product label Marking tube (White) 1 20 dia. 65 30 dia. 15 0 -2 White (M-16) M5% (30) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6FY 1M 2 E52-P6FY 2M 4 E52-P6FY 4M Exposed-lead Models Specifications E52-P10AEY Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Crimping terminal Y type for M3.5 Product label Transparent Marking tube (White) Siliconized shrinkable tube Shrinkable tube (Black) Red (A) Protective tubing material SUS316 Max. detectable temperature 250C White (B) Temperature range 0C to 250C White (B) Lead wire Fluororesin-covered wire (PFA) with 1.0 outer dia. 7/0.18 -50C to 150C 3.20.05 dia. Protective tubing (SUS316) Lead wire 30 305 8010 M4% 1003% Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting. Lead wire length (m) Model 1 E52-P10AEY 1M 2 E52-P10AEY 2M 4 E52-P10AEY 4M 17 E52 Low-cost Thermocouples Exposed-lead Models with Spring E52-CA@ASY, E52-IC@ASY Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing (SUS304) Protective tubing material SUS304 Thermal contact Non-grounded type Temperature range 0C to 400C: K (CA) 0C to 350C: J (IC) Lead wire 100 +0.02 4.8 0 dia. +0.2 14.5 -0.1 dia. Sleeve (Brass nickel chrome plating) 120.05 dia. Shrinkable tube (CA:Blue, IC:Yellow) Protective spring (SUS304) Lead wire 110.2 dia. 8.20.1 dia. Crimping terminal Y type for M3.5 Marking tube (White) Red (+) + - 50.5 6.31 181 L3 Fully glass-wool-covered compensating cable and external dimensions of approx. 5.1 x 3.0 4/0.65 0C to 180C 1.20.02 dia. White (-) (20) (70) 1501 322 8010 M1% L: Protective tubing length M: Lead wire length Note: The sleeve resists temperatures ranging between 0C and 100C. Note: The protective tubing is of pipe construction, which must not be bent. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 65 100 150 200 1 E52-CA6ASY 1M E52-IC6ASY 1M 2 E52-CA6ASY 2M E52-IC6ASY 2M 4 E52-CA6ASY 4M E52-IC6ASY 4M 1 E52-CA10ASY 1M E52-IC10ASY 1M 2 E52-CA10ASY 2M E52-IC10ASY 2M 4 E52-CA10ASY 4M E52-IC10ASY 4M 1 E52-CA15ASY 1M E52-IC15ASY 1M 2 E52-CA15ASY 2M E52-IC15ASY 2M 4 E52-CA15ASY 4M E52-IC15ASY 4M 1 E52-CA20ASY 1M E52-IC20ASY 1M 2 E52-CA20ASY 2M E52-IC20ASY 2M 4 E52-CA20ASY 4M E52-IC20ASY 4M 18 E52 Exposed-lead Models with Screw E52-CA1DY, E52-IC1DY Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0C to 400C: K (CA) 0C to 350C: J (IC) Lead wire Movable ring (Brass) End ring (Brass) Shrinkable tube (CA:Blue, IC:Yellow) Screw (SUS304) Protective copper wire 3.80.1 dia. Fully glass-wool-covered with external copper shield and external dimensions of approx. 3.1 x 2.0 1/0.65 0C to 180C Terminal shape Sleeve (Brass nickel plated) Y-type crimp terminal for M3.5 Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, or W1/4) when ordering. 3. The thermocouple is not of airtight construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Lead wire Crimping terminal Y type for M3.5 Marking tube (White) Red Red (+) PVC less tube B Blue 120 91 50.05 dia. 3.81 2.8 +0.3 0 10.1 Black (-) (20) 0 10 -0.5 A0.3 M1% C Internal Construction (E52-CA1DY) 0.65-dia. black wire Movable ring Brass Cut after silver soldering (70) 8010 Closely wound enamel-bonded coil. M6 Lead wire length (m) Screw W1/4 M6 M8 (P=1.27) (P=1.0) (P=1.25) A (mm) 4.3 4 B (mm) 11.5 11.5 5.3 15 C (mm) 10 10 13 Brass pipe Screw Shielded glass-wool lead wire Installation Example Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Workpiece Note: E52-CA1DY with the same shape and multiple element wires are also available (E52-CA1DY-40). Refer to page 30 for details. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model M6 screw M8 screw W1/4 screw 1 E52-CA1DY M6 1M E52-IC1DY M6 1M 2 E52-CA1DY M6 2M E52-IC1DY M6 2M 4 E52-CA1DY M6 4M E52-IC1DY M6 4M 1 E52-CA1DY M8 1M E52-IC1DY M8 1M 2 E52-CA1DY M8 2M E52-IC1DY M8 2M 4 E52-CA1DY M8 4M E52-IC1DY M8 4M 1 E52-CA1DY W1/4 1M E52-IC1DY W1/4 1M 2 E52-CA1DY W1/4 2M E52-IC1DY W1/4 2M 4 E52-CA1DY W1/4 4M E52-IC1DY W1/4 4M 19 E52 Exposed-lead Models with Flange Specifications E52-CA6F-N, E52-IC6F-N Element type K (CA), J (IC) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0C to 350C: K (CA) 0C to 350C: J (IC) Lead wire Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0 1/0.32 0C to 150C Silver brazing Siliconized shrinkable tube Flange (SUS304) 3x3.5 dia. 120 120 (M-16) M5% Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The protective tubing is of pipe construction, which must not be bent. 3. Do not use in locations subject to excessive vibration and shock. Doing so may cause disconnection. Element type: K (CA) Element type: J (IC) Model 1 E52-CA6F-N 1M E52-IC6F-N 1M 2 E52-CA6F-N 2M E52-IC6F-N 2M 4 E52-CA6F-N 4M E52-IC6F-N 4M K (CA) Dimensions Class 2 (0.75) Silver brazing Siliconized shrinkable tube SUS304 Fluororesin-covered thermocouple wire (PFA) with external dimensions of 2.5 x 1.5 1/0.65 0C to 150C (30) White (-) (75) 8010 (30) 15 652 Class Lead wire Red (+) 20 dia. Element type 0C to 350C: K (CA) 1 30 dia. E52-CA6F-N-25 Temperature range Peel treatment (10) 40.05 dia. Specifications Thermal contact Grounded type Product label Lead wire Protective tubing (SUS304) Lead wire length (m) Protective tubing material Shrinkable tube (CA:Blue, IC:Yellow) 3x3.5 dia. 120 120 Flange (SUS304) Shrinkable tube (CA:Blue, IC:Yellow) Product label Lead wire Protective tubing (SUS304) Peel treatment Red (+) (10) 40.05 dia. 1 (30) 20 dia. 30 dia. 652 15 (30) White (-) (75) 8010 (M-16) M5% Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Model 1 E52-CA6F-N-25 1M 2 E52-CA6F-N-25 2M 4 E52-CA6F-N-25 4M 20 E52 Exposed-lead Models with Screws Specifications E52-CA6D-N, E52-IC6D-N Element type K (CA), J (IC) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Taper screw for tube R1/8 (SUS304) Siliconized shrinkable tube Full-circled welding Shrinkable tube (CA:Blue, IC:Yellow) Product label Peel treatment Lead wire Protective tubing (SUS304) Thermal contact Grounded type Temperature range 0C to 350C: K (CA) 0C to 350C: J (IC) Lead wire Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0 1/0.3 0C to 150C Red (+) (16) 40.05 dia. (30) 14 Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The protective tubing is of pipe construction, which must not be bent. 3. Do not use in locations subject to excessive vibration and shock. Doing so may cause disconnection. Element type: K (CA) 1 E52-CA6D-N 1M E52-IC6D-N 1M 2 E52-CA6D-N 2M E52-IC6D-N 2M 4 E52-CA6D-N 4M E52-IC6D-N 4M E52-CA6D-N-25 Element type K (CA) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Taper screw for tube R1/8 (SUS304) Siliconized shrinkable tube Full-circled welding Shrinkable tube (CA:Blue, IC:Yellow) Product label Peel treatment Lead wire Protective tubing (SUS304) Red (+) Thermal contact Grounded type Lead wire Fluororesin-covered thermocouple wire (PFA) with external dimensions of 2.5 x 1.5 1/0.65 0C to 150C Element type: J (IC) Model Specifications 0C to 350C: K (CA) White (-) (M-16) M5% 15 652 Lead wire length (m) Temperature range (10) (75) 8010 (30) (16) 40.05 dia. (30) 14 (10) (75) 8010 (30) (M-16) M5% 15 652 White (-) Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Model 1 E52-CA6D-N-25 D4.0 1M 2 E52-CA6D-N-25 D4.0 2M 4 E52-CA6D-N-25 D4.0 4M Exposed-lead Models Specifications E52-CA10AE-N, E52-IC10AE-N Element type K (CA), J (IC) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Fluorocarbon resin protective tubing Protective tubing 3.20.05 dia. (SUS304) Shrinkable tube (CA:Blue, IC:Yellow) Peel treatment Product label Red (+) Thermal contact Non-grounded type Temperature range 0C to 350C: K (CA) 0C to 200C: J (IC) Lead wire Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0 1/0.32 0C to 180C Swage Lead wire (30) M5% 1005 Note: 1. 2. 3. 4. (10) (75) 8010 White (-) The thermocouple is a single wire from the tip to the terminal. Lead wire length M: 1, 2, or 4 m The protective tubing is of pipe construction, which must not be bent. The thermocouple cannot be mounted using a PT@ Compression Fitting. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA10AE-N 1M E52-IC10AE-N 1M 2 E52-CA10AE-N 2M E52-IC10AE-N 2M 4 E52-CA10AE-N 4M E52-IC10AE-N 4M 21 E52 Exclusive Models Thermocouples Thermocouples for Molding Machines Specifications E52-CA2GVY, E52-IC2GVY Element type K (CA), J (IC) Dimensions Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0C to 350C Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia. 1/1.0 0C to 180C Spring retainer (Brass nickel plated) Bayonet (Brass nickel plated) Protective tubing (SUS304) Shrinkable tube (CA:Blue, IC:Yellow) Spring 15 dia. 6.8 dia. Product label Marking tube Red (Red) Lead wire 4.80.05 dia. 252 15 White/Red Stripes (+) White Marking tube (White) (80) 8510 (30) 20 10010 Crimping terminal Y type for M3.5 CA: White/Blue Stripes (-) IC: White/Yellow Stripes (-) M5% Taper screw for tube R1/8 (Brass nickel plated) Note: The Adapter is included with the Thermocouple. If it is lost or damaged, you can order a replacement with the following model number. Adapter: Y92F-S1 8 dia.12 dia. 10 5 dia. 10 15 Details of mounting bracket Lead wire length (m) Element type: K (CA) Lead wire length (M): 1 or 2 m Element type: J (IC) Model 1 E52-CA2GVY 1M E52-IC2GVY 1M 2 E52-CA2GVY 2M E52-IC2GVY 2M Thermocouples with Crimp Terminal Specifications E52-CA1GTY, E52-IC1GTY Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0C to 300C Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia. 1/1.0 0C to 150C Terminal shape Crimping terminal Y type for M3.5 Temperature measuring junction Marking tube (White) Shrinkable tube (CA:Blue, IC:Yellow) Crimping terminal round type for M4 (N1.25-4) Transparent vinyl tube Siliconized shrinkable tube White/Red Stripes (+) Product label 8 4.3 dia. Max. 6 dia. Lead wire Transparent 155 305 White (-) (80) 9010 M4% Lead wire length (M): 1 or 2 m Y-type crimp terminal for M3.5 Note: The E52-CA1GTY is also available with double elements. Refer to page 30 for details. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA1GTY 1M E52-IC1GTY 1M 2 E52-CA1GTY 2M E52-IC1GTY 2M 22 E52 Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications E52-P2GSY Element type Pt100 Dimensions Class Class B Protective tubing material SUS304 With brass-nickelplated bracket Conductor type 3-conductor system Temperature range -50C to 250C Lead wire Silicone-covered 3-conductor cable and approx. 3.9 dia. 30/0.08 -50C to 150C Blacket (Brass nickel plated) 4x3.2 dia. Siliconized shrinkable tube (7.5 dia.) Lead wire 3 Crimping terminal Y type for M3.5 Marking tube (White) Shrinkable tube Product label (Black) Red (A) White (B) 5 201 White (B) 140.5 Transparent 200.5 1.5 4.5 305 (50) 6 281 (30) (80) M4% Lead wire length (m) 9010 Lead wire length (M): 1 or 2 m Model 1 E52-P2GSY 1M 2 E52-P2GSY 2M Platinum Resistance Thermometers for Room Temperature Measurement Specifications E52-P10GRY Element type Pt100 Dimensions Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Temperature range -50C to 60C Lead wire Vinyl-covered 3-conductor cable with 6.1 dia. 20/0.18 -25C to 60C Product label Terminal box 85 2x8 dia. 60 701 421 69.51 Protective piping (Brass nickel plated) Crimping terminal Y type for M3.5 Chain Marking tube (Red) Protective tubing (SUS304) Red Shrinkable tube (Black) 561 22.21 dia. 8 dia. Red (A) White (B) 4.8 dia. Black (B) Lead wire 4.51 (30) (95) 1004 971 Lead wire length (m) 2 White Marking tube (White) (80) 8510 M5% Model E52-P10GRY 2M Waterproof Platinum Resistance Thermometers Specifications E52-P10GPY Element wire Pt100 Class Class B Protective tubing material SUS304 Conductor type Vinyl-covered 3-conductor cable with 6.1 dia. 12/0.18 -25C to 60C Resistive pressure 981 kps Crimping terminal Y type for M3.5 Shrinkable tube (Black) Protective tubing (SUS304) Marking tube (Red) Sleeve (SUS304) Full-circled Welding 3-conductor system Temperature range 0C to 70C (underwater) -20C to 70C (in the air) Lead wire Dimensions Red Lead wire Product label Red (A) White (B) 70.2 dia. 20 dia. White Marking tube (White) (30) (80) 8510 M5% 12 1002 62 5 Black (B) Lead wire length (M): 1 or 2 m Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52-P5AY-40 if waterproof lead wires are required for use underwater. Refer to page 25 for details. Lead wire length (m) Model 2 E52-P10GPY 2M 4 E52-P10GPY 4M 23 E52 Corrosion-resistant Models with Fluororesin-covered Protective Tubing Thermocouples Exposed-lead Models Specifications E52-CA20AY-1 Element type K (CA) Class Class 2 (0.75) Protective tubing material ASTM316L with Fluororesin-covered (FEP) tube Thermal contact Non-grounded type Temperature range 0C to 180C Lead wire Vinyl-covered: -20C to 70C Dimensions Sheath (ASTM316L) Ds0.05 Fixed with adhesive tape and siliconized shrinkable tube Shrinkable tube (CA:Blue, IC:Yellow) Sleeve (SUS304) FEP-covered tubing Crimping terminal Y type for M3.5 Marking tube (White) Product label d Red (+) White (-) D0.1 5 22 +9 -5 Lead wire 8 Transparent 305 (L-5) L +4 0 Model (80) 9010 M4% 55 Protective Protective tubing tubing length L diameter (cm) E52-CA20AY-1 D=4.6 2M 20 D = 4.6 E52-CA20AY-1 D=6 2M D = 6.0 E52-CA20AY-1 D=8 2M D = 8.0 Sleeve tube diameter thickness (mm) (mm) Sleeve length (mm) d=8 l = 55 0.7 Lead wire length (m) 0.5 0.6 d = 11 l = 55 0.8 Platinum Measurement Exposed-lead Models Specifications E52-P20AY-1 Element type Pt100 Class Class B Protective tubing material SUS316 with Fluororesin-covered (FEP) tube Conductor type 3-conductor system Temperature range -80C to 180C Lead wire Vinyl-covered: -20C to 70C Dimensions Crimping terminal Y type for M3.5 Fixed with adhesive tape and Tube nose shape : siliconized shrinkable tube Round Marking tube Sheath (SUS316) Shrinkable tube (Black) (Red) FEP-covered tubing Red Sleeve (SUS304) Product label Lead wire Red (A) White (B) D0.1 Ds0.05 (10) A Black (B) 8 dia. (10) (20) L+5 3% Model (30) 35 M4% Marking tube White (White) (80) 8510 Protective Protective Sleeve Coating Lead wire tubing tubing diameter thickness length (m) length L diameter (mm) (mm) (cm) E52-P20AY-1 D=4.6 2M 20 D = 4.6 d=8 0.7 E52-P20AY-1 D=6 2M D = 6.0 d=8 0.6 E52-P20AY-1 D=8 2M D = 8.0 d=8 0.8 2 24 E52 FEP-molded Models (Completely Waterproof) Specifications E52-P5AY-40 Element type Pt100 Class Class B Protective tubing material Fluororesin (FEP) tube (element / fluororesin mold (FEP)) Conductor type 3-conductor system Temperature range -50C to 180C Lead wire Fluororesin (FEP) cover (with outer cover): -50C to 180C Dimensions Crimping terminal Y type for M3.5 Fusion (Completely waterproof) +0.1 6 -0.5 dia. Lead wire FEP tube Transparent Shrinkable tube (Black) Product label Marking tube (White) Red (A) White (B) White (B) +4 305 65 -1 (80) 9010 M4% Model Lead wire length (m) E52-P5AY-40 2M 2 E52-P5AY-40 4M 4 E52-P5AY-40 6M 6 E52-P5AY-40 8M 8 25 E52 Pressure-resistant Explosion-proof (IICT6) Models Thermocouples Enclosed-terminal Models E52-CA@@C-N-6 Dimensions (131.5) Explosion-proof display label Back: Product label 110 L L23% L1=50 Official approval success label Socket (SUS304) Support (SUS304) Sheath (ASTM316L) 15 dia. (113) 6.40.05 dia. Full-circled Welding Cap Terminal box Chain (64.5) Pressure-resistant explosion-proof cable ground (Adopted cable diameter: for 9-10 dia.) 70 (10) Specifications Element type K (CA) Class Class 2 (0.75) Class 3 (Level 1.5) at 40C and under Protective tubing material L2 section: ASTM316L L1 section: SUS304 Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosion-protected IICT6 tions class and ignitability Explosion-proof temperature range -20C to 85C Lead wire wiring method Pressure-resistant packing cable ground type Conduit thread G1/2 Installation method Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) Model Protective tubing length L (cm) Protective tubing diameter L2 (mm) E52-CA20C-N-6 D=6.4 L2=150 20 D = 6.4 150 E52-CA35C-N-6 D=6.4 L2=300 35 D = 6.4 300 E52-CA50C-N-6 D=6.4 L2=450 50 D = 6.4 450 E52-CA75C-N-6 D=6.4 L2=700 75 D = 6.4 700 26 E52 Platinum Resistance Thermometers for Surface Temperature Measurement Enclosed-terminal Models E52-P@@C-N-6 Dimensions 110 L (131.5) Explosion-proof display label Back: Product label L23% L1=50 Official approval success label Socket (SUS304) 15 dia. Support (SUS304) Sheath (ASTM316L) (113) 6.40.05 dia. Full-circled Welding Cap Terminal box Chain (64.5) Pressure-resistant explosion-proof cable ground (Adopted cable diameter: for 9-10 dia.) 70 (10) Specifications Element type Pt100 Class Class B Protective tubing material L2 section: ASTM316L L1 section: SUS304 Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosion-protected IICT6 tions class and ignitability Explosion-proof temperature range -20C to 85C Lead wire wiring method Pressure-resistant packing cable ground type Conduit thread G1/2 E52-P20C-N-6 D=6.4 L2=150 20 D = 6.4 150 Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) E52-P35C-N-6 D=6.4 L2=300 35 D = 6.4 300 E52-P50C-N-6 D=6.4 L2=450 50 D = 6.4 450 E52-P75C-N-6 D=6.4 L2=700 75 D = 6.4 700 Installation method Model Protective tubing length L (cm) Protective tubing diameter L2 (mm) 27 E52 Double-element Models Thermocouple Exposed-lead Models Specifications E52-CA20AY-7 Element type K (CA) Dimensions Class Class 2 (0.75) Thermal contact Non-grounded type Temperature range 0C to permissible temperature limit Lead wire Vinyl-covered with external dimensions of 2.4 x 4.1 7/0.3 -20C to 70C Product label Sleeve (SUS304) Protective tubing ASTM316L material (with sheath) Sheath (ASTM316L) Crimping terminal Y type for M3.5 Transparent Marking tube (White) Shrinkable tube (Blue) Swage Lead wire 11 dia. D0.05 305 L3% Red (+) White (-) Red (+) White (-) (80) 9010 M4% 55 Permissible Temperature in Dry Air D Element wire K (CA) ASTM316L 3.2 dia. 750C 4.8 dia. 800C 6.4 dia. 800C 8.0 dia. 900C Model Protective Protective Sleeve Permissible Lead wire tubing length L tubing diameter Temperature length (m) (cm) diameter (mm) (C) E52-CA20AY-7 D=3.2 2M 20 D = 3.2 d = 11 750 2 E52-CA20AY-7 D=4.8 2M D = 4.8 d = 11 800 2 E52-CA20AY-7 D=6.4 2M D = 6.4 d = 11 800 2 E52-CA20AY-7 D=8.0 2M D = 8.0 d = 11 900 2 Platinum Resistance Thermometers Exposed-lead Models Specifications E52-P20AY-7 Element type Pt100 Dimensions Class Class B Protective tubing ASTM316L material (with sheath) Conductor type 3-conductor system Temperature range -200C to 450C Lead wire Vinyl-covered with 6.5 dia. 19/0.18 -20C to 70C Wire mark (1,2) (White) Contradistinctive view Shrinkable tube (Black) Sleeve (SUS304) Sheath (ASTM316L) Marking tube (White) Product label Lead wire 11 dia. Swage D0.05 Crimping terminal Y type for M3.5 Transparent Red (A) White (B) White/Black Stripes (B) Red (A) 1 2 White (B) 305 L3% Model E52-P20AY-7 D=4.8 2M E52-P20AY-7 D=6.4 2M 55 M4% Protective tubing length L (cm) 20 White/Black Stripes (B) (80) 9010 Protective tubing diameter Lead wire length (m) D = 4.8 2 D = 6.4 2 28 E52 Enclosed-terminal Models Specifications E52-P20C-N-7 Element type Pt100 Class Class B Protective tubing material ASTM316L (with sheath) Conductor type 3-conductor system Temperature range -200C to 450C Dimensions (92) Cap Product label Socket (SUS304) 38 dia. Swage 82 dia. Sheath (ASTM316L) D0.05 (86) Chain G3/4 (Packing internal diameter : 12 dia.) (15) Terminal box 53 Model L-503% Protective tubing Protective length L (cm) tubing diameter E52-P20C-N-7 D=4.8 20 D = 4.8 E52-P20C-N-7 D=6.4 20 D = 6.4 Note: The length L is in centimeters, but "50" is 50 millimeters. Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L - 50 = 200 - 50 = 150 mm. 29 E52 Silicone-covered Lead Wires Models Thermocouples Exposed-lead Models with Screws Specifications Element type K (CA) Class Class 2 (0.75) Screw material SUS304 Thermal contact Grounded type Temperature range 0C to 300C Lead wire Silicone-covered with external dimensions of 3.5 x 4.9 30/0.1 0C to 150C Terminal shape Y-type crimp terminal for M3.5 Note: Refer to the installation example for the E52-CA1DY. E52-CA1DY-40 Dimensions Screw (SUS304) Crimping terminal Y type for M3.5 Sleeve (Brass nickel plated) Marking tube (White) Protective spring (SUS304) Red 80.05 dia. Shrinkable tube (Blue) Red (+) 0.6 dia. +0.05 Lead wire 6.5 0 dia. Movable ring (Brass) End ring (Brass) 3.80.1 dia. B Blue 120 131 2.8 +0.3 0 10.1 10 White (-) 805 0 -0.5 (20) A0.3 (70) 8010 M1% C Model Screw pitch Lead wire length (m) E52-CA1DY-40 M6 1M M6 (P=1.0) 1 E52-CA1DY-40 M6 2M M6 (P=1.0) 2 E52-CA1DY-40 M6 4M M6 (P=1.0) 4 Thermocouples with Crimp Terminal Specifications Element type K (CA) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0C to 200C Lead wire Silicone-covered compensating cable with external dimensions of 3.2 x 4.6 30/0.1 0C to 150C Terminal shape Y-type crimp terminal for M3.5 E52-CA1GTY-14 Dimensions Crimping terminal round type for M4 (N1.25-4) Siliconized shrinkable tube Shrinkable tube (CA:Blue, IC:Yellow) 6.6 Max. 7 dia. Crimping terminal Y type for M3.5 Transparent Marking tube (White) Red (+) Product label Lead wire Lead wire length (M): 1 or 2 m 4.3 dia. White (-) 155 305 (80) 9010 Model Lead wire length (m) E52-CA1GTY-14 1M 1 E52-CA1GTY-14 2M 2 M4% 30 E52 Special models for Packaging Machines Model Number Legend The type of protective tubing length, and lead length can be specified as shown below. E 52 - C A A Y D=1 S M Code CA Element type K Protective tubing length L (cm) Specify the length in centimeters within the following range: Unit (cm) Diameter (D) 1.0 1.0 1.0 Length (L) 6 12 3 to 100 (in centimeters, variable) Code A Terminal type Exposed lead wires Code Y Terminal processing Y-type crimp terminals for M3.0 Code D=1 Protective tubing diameter (D) Protective tubing structure 1 mm Sheathed Code S Application Temperature sensors for packaging machines Code 1 2 Compensating conductor Heat resistant (7 cores) Flexible and heat resistant (30 cores) Lead wire length M (m) Specify the M length in meters. Range: 0.5, 1, 2, or 0.5 to 12 (in meters, variable) Example: Element: K, protective tubing length: 12 cm, exposed leads, Y-type crimp terminals for M3.0, protective tubing diameter: 1 mm, flexible and heat resistive, lead length: 2 m E52-CA12AY D=1 S2 2M 31 E52 Sheathed Thermocouples Specifications Element type K (CA) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0C to 650C Note: Usage together with the automatic filter adjustment function of E5@D Digital Temperature Controllers is recommended. Exposed-lead Models E52-CA@AY Dimensions Y-type crimp terminals for M3.0 Red: + Sleeve (PPS resin) *2 Product label Sheath (ASTM316L) *3 Shrinkable tube (blue) +0.1 S1: 5.5 dia. -0.3 1 0.05 dia. Mark tube (white) Lead wire *1 +0.1 S1: 2.8 dia. S2: 3.6 dia. S2: 6.4 dia. -0.3 White: - (80) 305 L3% 30 M4% 9010 *1. Lead wires (compensating conductor) (excluding Y-type crimp terminals) Heat-resistance model (0 to 200C): PFA glass-wool sheath with stainless outer shield Flexible, heat-resistance model (0 to 200C): PFA glass-wool sheath with stainless outer shield *2. Temperature range of sleeve: 0 to 260C *3. The sheath can be easily bent. Performance will not be adversely affected even if the sheath is bent somewhat. Do not bend the sheath beyond the following value. Minimum bending radius: 2 mm Bendable section: 8 mm or farther from the end List of Models Custom-made models are available on request. Refer to page 31 for details. Terminal type Protective tubing diameter D (mm) Protective tubing length L (cm) Lead wire length M (m) Lead wire type Exposed-lead Models 1 dia. Flexible Heat resistive Heat resistive 12 1 2 Model Heat resistive 6 0.5 Flexible Heat resistive E52-CA6AY D=1 S1 0.5M --E52-CA12AY D=1 S1 0.5M --- E52-CA6AY D=1 S1 1M E52-CA6AY D=1 S2 1M E52-CA12AY D=1 S1 1M E52-CA12AY D=1 S2 1M --E52-CA6AY D=1 S2 2M --E52-CA12AY D=1 S2 2M 32 E52 Installation Method A Temperature Sensor for Packing Machines has a diameter of 1.0 mm. To measure the temperature close to the seal surface, mount the Sensor as close as possible to the surface. The following installation methods are assumed. Example 1: Groove for Temperature Sensor created in heating plate and Temperature Sensor secured with mounting brackets. To correctly measure the surface temperature, the following installation conditions are recommended. Enlargement Example 2: Groove for Temperature Sensor created in heating plate and Temperature Sensor secured with a cover. Bend to a radius of 2 mm or larger. Insert the end by 8 mm or longer. Approx. 1 to 3.5 mm Heater Example 3: Lateral hole for the Temperature Sensor created in the heating plate and the Temperature Sensor inserted into it. There is a temperature sensing element at the tip of the Sensor. Always press the tip against the heating plate. Always insert the Temperature Sensor all the way to the surface of the packing material. Use the following brackets or the equivalent to mount a Temperature Sensor for Packaging Machines to a hot plate. Mounting Application Manufacturer Model number bracket Square Shims (1) 1-mm-dia. protective tube bracket Misumi Corporation ASFCS-series Cable Clips Misumi Corporation COPU3-20P Sleeve bracket (S1) Cable Clamp Digi-Key RPC1156-ND (2) Cable Clips Misumi Corporation COPU4-20P Sleeve bracket (S2) Cable Clamp Digi-Key RPC1474-ND Note: All of the above mounting brackets are SUS304. (1) (2) 33 E52 Thermistors Element Interchangeable Thermistor for E5CS and E5C2 Temperature Ranges Temperature range Color code Nominal resistance Thermistor constant -50C to 50C Blue 6 k (0C) 3390K 0C to 100C Black 6 k (0C) 3390K 50C to 150C Red 30 k (0C) 3450K 100C to 200C Yellow 0.55 k (200C) 4300K 150C to 300C Green 4 k (200C) 5133K Lead wire A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with 0.86 outer dia. each Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors and external dimensions of 2.5 x 1.55 Specifications Item Coupling method E52-THE@@ Element interchangeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/C in still air Lead wire heat resistive temperature 180C Error Detectable temperature Error -50C to 100C 1C max. 100C to 350C 1% max. of detectable temperature Permissible Temperature Detectable temperature Operating temperature -50C to 50C 100C 0C to 100C 150C 50C to 150C 200C 100C to 200C 250C 150C to 300C 350C Note: Models with non-standard lead wire length and protective tubing length are available on request. This Thermistor is a dedicated Thermistor for the E5C2 and E5CS. 34 E52 Exposed-lead Models E52-THE5A Dimensions Temperature range Protective tubing (SUS304) Protective tube Lead wire Swage 40.08 dia. (5) (4) Transparent Peel treatment Marking tube (15) (10) (50) M5% 501 Model -50C to 50C E52-THE5A -50-50C 1M 0C to 100C E52-THE5A 0-100C 1M 50C to 150C E52-THE5A 50-150C 1M 100C to 200C E52-THE5A 100-200C 1M 150C to 300C E52-THE5A 150-300C 1M Note: The lead wires have no polarity Exposed-lead Models with Screws E52-THE6D Dimensions Protective tubing (SUS304) 10 6 Protective tube Swage 40.08 dia. Lead wire Marking tube Peel treatment Transparent (16) Tapered screw for tube R1/8 14 (5) (SUS304) 651 (4) (15) (15) (50) (10) Temperature range Model -50C to 50C E52-THE6D -50-50C 1M 0C to 100C E52-THE6D 0-100C 1M 50C to 150C E52-THE6D 50-150C 1M 100C to 200C E52-THE6D 100-200C 1M 150C to 300C E52-THE6D 150-300C 1M M5% Note: The lead wires have no polarity Exposed-lead Models with Flange E52-THE6F Dimensions Flange (SUS304) 3x3.5 dia. 120 120 Protective tubing (SUS304) Swage 651 (4) (15) Peel treatment Lead wire (15) (5) 20 dia. 30 dia. Marking tube Transparent Protective tube (1) 40.08 dia. Temperature range Silver brazing (50) Model -50C to 50C E52-THE6F -50-50C 1M 0C to 100C E52-THE6F 0-100C 1M 50C to 150C E52-THE6F 50-150C 1M 100C to 200C E52-THE6F 100-200C 1M 150C to 300C E52-THE6F 150-300C 1M (10) M5% Note: The lead wires have no polarity Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension. 2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the temperature range. 35 E52 (Ferrule) General-purpose Models (with Ferrule) Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Platinum Resistance Thermometers 1. Element type P: Pt100 2. Protective tubing length (L) Specify the length in centimeters within the following range: Unit (cm) E52-P@AF Diameter (D) Length (L) 3.2 7 to 100 4.8 10 to 600 6.4 13 to 1,300 4. Diameter 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) E52-@@AF only 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) E52-@@AF only 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) E52-@@AF only 5. Heat resistance Code 3. Terminal AF: Exposed lead wires (with Ferrule) Temperature range Lead type --- -20C to 70C Sleeve: 0C to 70C Vinyl-covered NETU 0C to 180C Sleeve: 0C to 100C Glass-wool-covered, externally shielded with stainless Specify for E52-P@AF model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@AF only: Range: 0.5, 1 to 100 m Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42AF D=4.8 NETU 10M Sheathed Platinum Resistance Thermometers Refer to Model Number Legend above for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 (E52-P@AF) ASTM316L (E52-P@B-N, E52-P@C-N) Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia Conductor type 3-conductor system Temperature range -196C to 450C (in dry air) 36 E52 (Ferrule) Exposed-lead Models E52-P@AF Dimensions Lead Wire Ferrule * SUS304 sleeve Sheath (SUS316) Shrinkable tube (black) Caulking D0.05 8 dia. * Standard (-20C to 70C): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0C and 70C. * Heat Resistive (0C to 180C): Fully glass-wool-covered with thirty 0.12-dia. conductors (0.3 mm thick) externally shielded with stainless steel, 4 mm in outer dia. The sleeve resists a temperature range between 0C and 100C. * Lead Wire Length (M): 1, 2, 4, or 8 m Turquoise Product label Lead wire Maker tube Red (A) A B White (B) B Black (B) (30) 40 L3% M4% 8510 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Model Information Custom-made models are available on request. Refer to page 36 for details. Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 4.8 dia. 20 35 50 Lead wire type Lead wire length M (m) 1 2 4 8 Model Standard E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 1M 2M 4M 8M Heat resistive E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 1M 2M 4M 8M Heat resistive E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 1M 2M 4M 8M Heat resistive E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 1M 2M 4M 8M Heat resistive E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 1M 2M 4M 8M Heat resistive E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 8M 4M 1M 2M Standard Heat resistive E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M 37 E52 (Ferrule) Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Thermocouples 1. Element type CA:K 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) E52-CA@AF (Exposed-lead Model) Diameter (D) Length (L) 1 2 to 200 1.6 3 to 500 3.2 5 to 2,000 4.8 8 to 2,300 6.4 10 to 1,200 8 12 to 1,000 3. Terminal AF: Exposed lead wires (with Ferrule) (element type: K, J) 4. Diameter Specify the protective tubing material according to the table. Code Diameter Protective tubing (D) construction Protective tubing material 1 1 mm Sheathed ASTM316L 1.6 1.6 mm Sheathed ASTM316L 3.2 3.2 mm Sheathed ASTM316L 4.8 4.8 mm Sheathed ASTM316L 6.4 6.4 mm Sheathed ASTM316L 8 8 mm Sheathed ASTM316L 5. Heat resistance Specify this item for the exposed-lead models only. Code Temperature range Lead type --- -20C to 70C Sleeve: 0C to 70C Vinyl-covered NETU 0C to 150C Sleeve: 0C to 100C Glass-wool-covered with external shield of stainless 6. Lead length (M) Specify the length in meters in the following range for the E52-CA@AF only. Range: 1 to 100 m 7. Protective tubing material Code --- Protective tubing material ASTM316L Element type K Examples Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA@AF D=4.8 NETU 10M 38 E52 (Ferrule) Sheathed Thermocouples Specifications Permissible Temperature in Dry Air D Element type K (CA) Class JIS class 2 (0.75) Thermal contact Non-grounded type Sheath material CA: ASTM316L Element wire K (CA) ASTM316L IC: ASTM316L 1 dia. 650C 1.6 dia. 650C 3.2 dia. 750C 4.8 dia. 800C 6.4 dia. 800C 8.0 dia. 900C Note: For details on the permissible temperature, refer to page D-5 of Introduction of Temperature Controllers (Cat. No. H900). Exposed-lead Models E52-CA@AF Dimensions Sheath (ASTM316L) Shrinkable tube (blue) SUS304 sleeve Ferrule * White Maker tube Red (+) Product label Caulking D0.05 d Lead wire * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. White (-) (80) 305 L3% 55 M4% 9010 Note: 1. Lead Wire (Compensating Conductor) * Standard (-20C to 70C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 2.4 x 4.1. * Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.8 x 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between -20C and 70C for standard models and 0C and 100C for heat-resistive models. Permissible Temperature in Dry Air D Unit (mm) D d Element wire J (IC) ASTM316L l 1 dia. 8 55 1 dia. 450C 1.6 dia. 8 55 1.6 dia. 450C 3.2 dia. 8 55 3.2 dia. 650C 4.8 dia. 8 55 4.8 dia. 750C 6.4 dia. 11 55 6.4 dia. 750C 8 dia. 11 55 8.0 dia. 750C 39 E52 (Ferrule) K (CA) Model Information (E52-CA@AF) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 38 for details. Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1 dia. 15 20 35 1.6 dia. 15 20 35 Exposed-lead Models 3.2 dia. 15 20 35 50 4.8 dia. 20 35 50 Standard E52-CA15AF D=1 1M E52-CA15AF D=1 2M E52-CA15AF D=1 4M E52-CA15AF D=1 8M Heat resistive E52-CA15AF D=1 NETU 1M Standard E52-CA20AF D=1 1M E52-CA20AF D=1 2M E52-CA20AF D=1 4M E52-CA20AF D=1 8M Heat resistive E52-CA20AF D=1 NETU 1M Standard E52-CA35AF D=1 1M E52-CA35AF D=1 2M E52-CA35AF D=1 4M E52-CA35AF D=1 8M Heat resistive E52-CA35AF D=1 NETU 1M E52-CA35AF D=1 NETU 2M E52-CA35AF D=1 NETU 4M E52-CA35AF D=1 NETU 8M Standard E52-CA15AF D=1.6 1M E52-CA15AF D=1.6 2M E52-CA15AF D=1.6 4M E52-CA15AF D=1.6 8M Heat resistive E52-CA15AF D=1.6 NETU 1M E52-CA15AF D=1.6 NETU 2M E52-CA15AF D=1.6 NETU 4M E52-CA15AF D=1.6 NETU 8M Standard E52-CA20AF D=1.6 1M E52-CA20AF D=1.6 2M E52-CA20AF D=1.6 4M E52-CA20AF D=1.6 8M Heat resistive E52-CA20AF D=1.6 NETU 1M E52-CA20AF D=1.6 NETU 2M E52-CA20AF D=1.6 NETU 4M E52-CA20AF D=1.6 NETU 8M Standard E52-CA35AF D=1.6 1M E52-CA35AF D=1.6 2M E52-CA35AF D=1.6 4M E52-CA35AF D=1.6 8M Heat resistive E52-CA35AF D=1.6 NETU 1M E52-CA35AF D=1.6 NETU 2M E52-CA35AF D=1.6 NETU 4M E52-CA35AF D=1.6 NETU 8M Standard E52-CA15AF D=3.2 1M E52-CA15AF D=3.2 2M E52-CA15AF D=3.2 4M E52-CA15AF D=3.2 8M Heat resistive E52-CA15AF D=3.2 NETU 1M E52-CA15AF D=3.2 NETU 2M E52-CA15AF D=3.2 NETU 4M E52-CA15AF D=3.2 NETU 8M Standard E52-CA20AF D=3.2 1M E52-CA20AF D=3.2 2M E52-CA20AF D=3.2 4M E52-CA20AF D=3.2 8M Heat resistive E52-CA20AF D=3.2 NETU 1M E52-CA20AF D=3.2 NETU 2M E52-CA20AF D=3.2 NETU 4M E52-CA20AF D=3.2 NETU 8M Standard E52-CA35AF D=3.2 1M E52-CA35AF D=3.2 2M E52-CA35AF D=3.2 4M E52-CA35AF D=3.2 8M Heat resistive E52-CA35AF D=3.2 NETU 1M E52-CA35AF D=3.2 NETU 2M E52-CA35AF D=3.2 NETU 4M E52-CA35AF D=3.2 NETU 8M Standard E52-CA50AF D=3.2 1M E52-CA50AF D=3.2 2M E52-CA50AF D=3.2 4M E52-CA50AF D=3.2 8M Heat resistive E52-CA50AF D=3.2 NETU 1M E52-CA50AF D=3.2 NETU 2M E52-CA50AF D=3.2 NETU 4M E52-CA50AF D=3.2 NETU 8M Standard E52-CA20AF D=4.8 1M E52-CA20AF D=4.8 2M E52-CA20AF D=4.8 4M E52-CA20AF D=4.8 8M Heat resistive E52-CA20AF D=4.8 NETU 1M E52-CA20AF D=4.8 NETU 2M E52-CA20AF D=4.8 NETU 4M E52-CA20AF D=4.8 NETU 8M Standard E52-CA35AF D=4.8 1M E52-CA35AF D=4.8 2M E52-CA35AF D=4.8 4M E52-CA35AF D=4.8 8M Heat resistive E52-CA35AF D=4.8 NETU 1M E52-CA35AF D=4.8 NETU 2M E52-CA35AF D=4.8 NETU 4M E52-CA35AF D=4.8 NETU 8M Standard E52-CA50AF D=4.8 1M E52-CA50AF D=4.8 2M E52-CA50AF D=4.8 4M E52-CA50AF D=4.8 8M Heat resistive E52-CA50AF D=4.8 NETU 1M E52-CA50AF D=4.8 NETU 2M E52-CA50AF D=4.8 NETU 4M E52-CA50AF D=4.8 NETU 8M E52-CA15AF D=1 NETU 2M E52-CA20AF D=1 NETU 2M E52-CA15AF D=1 NETU 4M E52-CA20AF D=1 NETU 4M E52-CA15AF D=1 NETU 8M E52-CA20AF D=1 NETU 8M 40 E52 (Ferrule) Low-cost Models (with Ferrule) Low-cost Platinum Resistance Thermometers Exposed-lead Models with Screws Specifications E52-P6DF Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Max. detectable temperature 250C Temperature range -50C to 250C Lead wire Fluororesin-covered wire (PFA) and approx. 1.0 dia. 7/0.18 -50C to 150C Tapered pipe thread Full-circled welding SUS304 R1/8 Silicon SUS304 shrinkable tube protective 4 dia.0.4 tubing Ferrule * Maker tube Lead wire Yellow Red (A) A B (16) Black (B) B Black (B) 60.5 100.5 14 Product label (30) 65 0 -2 (M-16) M5% 15 Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6DF 1M 2 E52-P6DF 2M 4 E52-P6DF 4M * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Exposed-lead Models with Flange Specifications E52-P6FF Element wire Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Three, 3.5 dia. 120 120 4 dia.0.4 Flange (SUS304) SUS304 protective tubing Ferrule * Nickel soldering Maker tube Silicon shrinkable tube Yellow Lead wire Red (A) A Sensor length 30 mm Max. detectable temperature 250C Temperature range -50C to 250C Lead wire Fluororesin-covered wire (PFA) and approx. 1.0 dia. 7/0.18 -50C to 150C Black (B) B B Black (B) Product label 1 20 dia. (30) 30 dia. 65 0 -2 (M-16) M5% 15 Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6FF 1M 2 E52-P6FF 2M 4 E52-P6FF 4M * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Exposed-lead Models Specifications E52-P10AEF Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS316 Max. detectable temperature 250C Temperature range 0C to 250C Lead wire Fluororesin-covered wire (PFA) and approx. 1.0 dia. 7/0.2 -50C to 150C Ferrule * Shrinkable tube (black) Product label Silicon SUS316 protective shrinkable tube 3.20.05 dia. tubing Maker tube Yellow Red (A) Lead wire A B White (B) B White (B) 30 305 8010 M4% 1003% Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting. Lead wire length (m) Model 1 E52-P10AEF 1M 2 E52-P10AEF 2M 4 E52-P10AEF 4M * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. 41 E52 (Ferrule) Low-cost Thermocouples Exposed-lead Models with Screw E52-CA1DF Specifications Element type K (CA) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0C to 400C: K (CA) Lead wire Fully glass-woolcovered with external copper shield and external dimensions of approx. 3.1 x 2.0 1/0.65 0C to 180C Dimensions Movable ring (brass) C Sleeve Ferrule * Shrinkable tube Turquoise SUS304 (Brass-nickel plating) (CA: Blue, Top ring (brass) screw Protective IC: Yellow) Maker tube copper wire Lead wire + Terminal shape B Red (+) 50.05 dia. 120 3.80.1 2.8 +0.3 0 10.1 0 10 -0.5 - 91 3.81 Black (-) (70) 8010 (20) A0.3 M1% * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Internal Construction (E52-CA1DF) 0.65-dia. black wire Movable ring Brass Ferrule Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, or W1/4) when ordering. 3. The thermocouple is not of airtight construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Cut after silver soldering Closely wound enamel-bonded coil. M6 Brass pipe Screw Lead wire length (m) Screw W1/4 M6 M8 (P=1.27) (P=1.0) (P=1.25) A (mm) 4.3 4 B (mm) 11.5 11.5 5.3 15 C (mm) 10 10 13 Shielded glass-wool lead wire Installation Example Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Workpiece Note: E52-CA1DF with the same shape and multiple element wires are also available (E52-CA1DF-40). Refer to page 46 for details. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Model M6 screw M8 screw W1/4 screw 1 E52-CA1DF M6 1M 2 E52-CA1DF M6 2M 4 E52-CA1DF M6 4M 1 E52-CA1DF M8 1M 2 E52-CA1DF M8 2M 4 E52-CA1DF M8 4M 1 E52-CA1DF W1/4 1M 2 E52-CA1DF W1/4 2M 4 E52-CA1DF W1/4 4M 42 E52 (Ferrule) Exclusive Models (with Ferrule) Thermocouples Thermocouples for Molding Machines Specifications E52-CA2GVF Element type K (CA) Dimensions Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Spring retainer Bayonet (Brass-nickel plating) (Brass-nickel plating) SUS304 protective 15 dia. tubing Product label Shrinkable tube (Blue) Ferrule * Marker White tube Lead wire Spring 4.80.05 dia. Thermal contact Grounded type 0C to 350C Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia. 1/1.0 0C to 180C R1/8 White/red stripe (+) 8 dia.12 dia. + - Temperature range 5 dia. 252 15 6.8 20 dia. 10010 (30) (80) 8510 M5% Lead wire length (m) Element type: K (CA) Model 1 E52-CA2GVF 1M 2 E52-CA2GVF 2M CA: White/blue stripe IC: White/yellow stripe (-) 10 10 15 Note: The Adapter is included with the Thermocouple. If it is lost or damaged, you can order a replacement with the following model number. Adapter: Y92F-S1 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Thermocouples with Crimp Terminal Specifications E52-CA1GTF Element type K (CA) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) M4, round crimp terminal (N1.25-4) Thermal contact Grounded type Temperature range 0C to 300C Lead wire Glass-wool-braided shield with maximum external dimensions of 2.6 x 4.0 1/0.65 0C to 150C Terminal shape Shrinkable tube (Blue) Silicone shrinkable tubing Lead wire 8 Ferrule * Marker tube Product label White/red stripe (+) + Turquoise Sensing point 4.3 dia. - White stripe (-) 6 dia. max. (80) 305 155 9010 M4% Lead wire length (m) Ferrule Note: The E52-CA1GTF is also available with double elements. Refer to page 46 for details. Element type: K (CA) Model 1 E52-CA1GTF 1M 2 E52-CA1GTF 2M * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications E52-P2GSF Element type Pt100 Dimensions Class Class B Protective tubing material SUS304 With brass-nickelplated bracket Conductor type 3-conductor system Temperature range -50C to 250C Lead wire Silicone-covered 3-conductor cable and approx. 3.9 dia. 30/0.08 -50C to 150C Brass-nickel-plated bracket Silicon Four, 3.2 dia. shrinkable tube (7.5-dia.) 3 5 1.5 4.50 6 Ferrule * Lead wire Product label Shrinkable tube (Black) Marker tube Yellow Red (A) A B 201 White (B) B 140.5 White (B) 200.5 305 (50) 281 Lead wire length (m) (30) M4% Model 1 E52-P2GSF 1M 2 E52-P2GSF 2M (80) 9010 * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. 43 E52 (Ferrule) Platinum Resistance Thermometers for Room Temperature Measurement Specifications E52-P10GRF Element type Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Dimensions Product label Terminal box 85 Two, 8 dia. 60 421 701 dia. Temperature range -50C to 60C Lead wire Vinyl-covered 3-conductor cable with 6.1 dia. 20/0.18 -20C to 60C 69.51 22.21 dia. Protective pipe (Brass-nickel plating) 8.0 dia. SUS304 protective tubing Chain Ferrule * Lead wire 561 White Shrinkable tube (Black) Red (A) A B White (B) B Black (B) 4.8 dia. Marker tube 4.51 (30) (95) 1004 971 M5% Lead wire length (m) 2 (80) 8510 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Model E52-P10GRF 2M Waterproof Platinum Resistance Thermometers Specifications E52-P10GPF Element wire Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Temperature range 0C to 70C (underwater) -20C to 70C (in the air) Lead wire Vinyl-covered 3-conductor cable with 6.1 dia. 12/0.18 -25C to 60C Resistive pressure 10 kg/cm2 max. Dimensions Full-circled welding Sleeve (SUS304) SUS304 protective tubing Shrinkable tube Ferrule * (Black) Product label Marker tube White 20 dia. Red (A) Lead wire A 70.2 dia. White (B) B B Black (B) (30) 12 (80) 8510 10010 62 5 M5% Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52-P5AF-40 if waterproof lead wires are required for use underwater. Refer to page 45 for details. * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Lead wire length (m) Model 2 E52-P10GPF 2M 4 E52-P10GPF 4M 44 E52 (Ferrule) Corrosion-resistant Models with Fluororesin-covered Protective Tubing (with Ferrule) FEP-molded Models (Completely Waterproof) Specifications E52-P5AF-40 Element type Pt100 Class Class B Protective tubing material Fluororesin (FEP) tube (element / fluororesin mold (FEP)) Conductor type 3-conductor system Temperature range -50C to 180C Lead wire Fluororesin (FEP) cover (with outer cover): -50C to 180C Dimensions Fused (completely waterproof) FEP-covered tubing 6 +0.1 -0.5 dia. Shrinkable tube (Black) Ferrule * Product label Marker tube White Lead wire Red (A) A B B 65 +4 -1 305 White (B) White (B) (80) 9010 M4% Model Lead wire length (m) E52-P5AF-40 2M 2 E52-P5AF-40 4M 4 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. 45 E52 (Ferrule) Silicone-covered Lead Wires Models (with Ferrule) Thermocouples Exposed-lead Models with Screws Specifications Element type K (CA) Class Class 2 (0.75) Screw material SUS304 Thermal contact Grounded type Temperature range 0C to 300C Lead wire Silicone-covered (0.1/30): 0C to 150C Terminal shape Ferrule Note: Refer to the installation example for the E52-CA1DY. E52-CA1DF-40 Dimensions Sleeve (Brass-nickel plating) Movable ring (brass) SUS304 screw Top ring (Brass) Protective spring (SUS304) 80.05 dia. 120 6.5 +0.05 dia. 0 * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Ferrule * Yellow Shrinkable tube (Blue) Maker tube Lead wire Red (+) + Model 3.80.1 2.8 10.1 10 - 0.6 dia. +0.3 0 131 E52-CA1DF-40 M6 1M M6 (P=1.0) 1 E52-CA1DF-40 M6 2M M6 (P=1.0) 2 8010 E52-CA1DF-40 M6 4M M6 (P=1.0) 4 White (-) (20) A0.3 Lead wire length (m) (70) 805 0 -0.5 Screw pitch M1% Thermocouples with Crimp Terminal Specifications Element type K (CA) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0C to 200C Lead wire Silicone-covered : 0C to 150C Terminal shape Ferrule E52-CA1GTF-14 Dimensions M4, round, crimp terminal (N1.25-4) 6.6 Ferrule * Shrinkable tube (Blue) Silicone shrinkable tubing Lead wire 7 dia. max. Maker tube Red (+) Product label + Sensing point - 4.3 dia. 155 Yellow 305 * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Model White (-) Lead wire length (m) (80) E52-CA1GTF-14 1M 1 9010 E52-CA1GTF-14 2M 2 M4% Lead wire length (M): 1 or 2 m 46 E52 (Ferrule) Special models for Packaging Machines (with Ferrule) Model Number Legend The type of protective tubing length, and lead length can be specified as shown below. E 52 - C A A F D=1 S M Code CA Element type K Protective tubing length L (cm) Specify the length in centimeters within the following range: Unit (cm) Diameter (D) 1.0 1.0 1.0 Length (L) 6 12 3 to 100 (in centimeters, variable) Code A Terminal type Exposed lead wires Code F Terminal processing Ferrules Code D=1 Protective tubing diameter (D) Protective tubing structure 1 mm Sheathed Code S Application Temperature sensors for packaging machines Code 1 2 Compensating conductor Heat resistant (7 cores) Flexible and heat resistant (30 cores) Lead wire length M (m) Specify the M length in meters. Range: 0.5, 1, 2, or 0.5 to 12 (in meters, variable) Example: Element: K, protective tubing length: 12 cm, exposed leads, Ferrules, protective tubing diameter: 1 mm, flexible and heat resistive, lead length: 2 m E52-CA12AF D=1 S2 2M 47 E52 (Ferrule) Sheathed Thermocouples Specifications Element type K (CA) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0C to 650C Note: Usage together with the automatic filter adjustment function of E5@D Digital Temperature Controllers is recommended. Exposed-lead Models E52-CA@AF Dimensions Ferrules Red: + Sleeve (PPS resin) *2 Product label Shrinkable tube (blue) Sheath (ASTM316L) *3 +0.1 S1: 5.5 dia. -0.3 1 0.05 dia. Mark tube (white) +0.1 dia. -0.3 S2: 6.4 Lead wire *1 S1: 2.8 dia. S2: 3.6 dia. White: - (80) 305 30 L3% M4% 9010 *1. Lead wires (compensating conductor) (excluding Y-type crimp terminals) Heat-resistance model (0 to 200C): PFA glass-wool sheath with stainless outer shield Flexible, heat-resistance model (0 to 200C): PFA glass-wool sheath with stainless outer shield *2. Temperature range of sleeve: 0 to 260C *3. The sheath can be easily bent. Performance will not be adversely affected even if the sheath is bent somewhat. Do not bend the sheath beyond the following value. Minimum bending radius: 2 mm Bendable section: 8 mm or farther from the end List of Models Custom-made models are available on request. Refer to page 47 for details. Terminal type Protective tubing diameter D (mm) Protective tubing length L (cm) Lead wire length M (m) Lead wire type Exposed-lead Models 1 dia. Flexible Heat resistive Heat resistive 12 1 2 Model Heat resistive 6 0.5 Flexible Heat resistive E52-CA6AF D=1 S1 0.5M --E52-CA12AF D=1 S1 0.5M --- E52-CA6AF D=1 S1 1M E52-CA6AF D=1 S2 1M E52-CA12AF D=1 S1 1M E52-CA12AF D=1 S2 1M --E52-CA6AF D=1 S2 2M --E52-CA12AF D=1 S2 2M For Installation Method, refer to page 33. 48 E52 Accessories Compression Fittings Model Information Model Screw of part Applicable a protective tubing diameter PT 1/8 D=1.0 R 1/8 1.0 dia. PT 1/8 D=1.6 1.6 dia. PT 1/8 D=3.2 3.2 dia. PT 1/8 D=4.8 Dimension b c d Flat diameter Part c Part b 5 13 10 14 14 5 15 12 17 14 4.8 dia. PT 1/4 D=3.2 R 1/4 3.2 dia. PT 1/4 D=4.8 4.8 dia. PT 1/4 D=6.4 6.4 dia. PT 3/8 D=8 R 3/8 8 dia. 5 19 15 21 17 PT 1/2 D=10 R 1/2 10 dia. 15.1 8 19 22 19 M 12 D=4.8 M 12 4.8 dia. 5 15 12 17 14 Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. The compression fitting is a screw that adjusts and secures the insertion length of Temperature Sensors with the above protective tubing diameters. The material of the Compression Fitting is SUS304 with internal fixing beads made of brass. a Sensor side Head side d c b Source: JIS B 0203 (Unit: mm) Tighten using the retaining screw to secure to the protective tubing. Material Protective tubing dia. D Main body SUS304 Lock bead Brass Retaining screw SUS304 <1/2> Front ring SUS316 Nut SUS316 Nominal thread size T.P.I. Outer (No. of diamethreads ter: d /inch) Root diameter: d1 Standard diameter position a (from pipe end) Minimum effective screw length: f R 1/8 28 9.728 9.147 8.566 3.97 0.91 2.5 R 1/4 19 13.157 12.301 11.445 6.01 1.34 3.7 R 3/8 19 16.662 15.806 14.950 6.35 1.34 3.7 R 1/2 14 20.955 19.793 18.631 8.16 1.81 5.0 a f Back ring SUS316 Main body SUS316 Effective diameter: d2 Tapered thread d d2 d1 Standard dia. Loose Flanges Model Information Applicable protective tubing diameter Material: Aluminum Model 3.2 dia. MF-1 D=3.2 4.8 dia. MF-1 D=4.8 6.4 dia. MF-1 D=6.4 8 dia. MF-1 D=8 10 dia. MF-2 D=10 12 dia. MF-2 D=12 15 dia. MF-2 D=15 22 dia. MF-2 D=22 Note: 1. Use the Loose Flange in atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400C maximum. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. MF-1 MF-2 120 120 Three, 5 dia. Three, 6.5 dia. 36 54 dia. 21 dia. D dia. M4 31 dia. D dia. 5 14 24 23 dia. 45 dia. M6 6.6 35 dia. 70 dia. 49 E52 Compensating Conductors The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between -20C and 70C and two types of heat-resistive models for a temperature range between 0C and 150C are available. Be sure to use the compensating conductor for the extension of the length of the thermocouple. Model Information Thermocouple R Heat resistance Exterior Model (Length) 1m 2m 4m 8m Standard Fully vinyl-covered (waterproof) WPRG-N 1M WPRG-N 2M WPRG-N 4M WPRG-N 8M Heat resistive Fully glass-wool-covered WPRH-N 1M WPRH-N 2M WPRH-N 4M WPRH-N 8M Fully glass-wool-covered with external shield WPRH6-N 1M WPRH6-N 2M WPRH6-N 4M WPRH6-N 8M of stainless steel K (CA) Standard Fully vinyl-covered (waterproof) WCAG-N 1M WCAG-N 2M WCAG-N 4M WCAG-N 8M Heat resistive Fully glass-wool-covered WCAH-N 1M WCAH-N 2M WCAH-N 4M WCAH-N 8M Fully glass-wool-covered with external shield WCAH6-N 1M WCAH6-N 2M WCAH6-N 4M WCAH6-N 8M of stainless steel J (IC) Silicone-covered (See note 2.) WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M Standard Vinyl covered (waterproof) WICG-N 1M WICG-N 2M WICG-N 4M WICG-N 8M Heat resistive Fully glass-wool-covered WICH-N 1M WICH-N 2M WICH-N 4M WICH-N 8M Fully glass-wool-covered with external shield WICH6-N 1M WICH6-N 2M WICH6-N 4M WICH6-N 8M of stainless steel Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above 100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details. 2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures. Specifications (JIS C1610-1995) Model WPRG-N Type of thermocouple R WPRH-N Use Code (See note.) K (CA) RCA-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 30 RCB-2-H Fully glass-wool-covered 0 to 150 60 100 7/0.32 Exterior color Black Standard KCC-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 Heat resistive KCB-2-H Fully glass-wool-covered 7/0.32 0 to 150 30/0.1 -20 to 150 100 140 Blue Fully glass-wool-covered with external shield of stainless steel WCAG-40 WICH6-N Error (C) Heat resistive WCAH6-N WICG-N Operating temperature range (C) Fully glass-wool-covered with external shield of stainless steel WCAH-N WICH-N Number of wires/wire diameter Standard WPRH6-N WCAG-N Exterior J (IC) Heat resistive KX-2-G for moving parts Silicone-covered Standard JX-2-G Fully vinyl-covered (waterproof) 7/0.3 -20 to 90 Heat resistive JX-2-H Fully glass-wool-covered 0 to 150 7/0.32 Yellow Fully glass-wool-covered with external shield of stainless steel Note: Symbols conform to JIS standards. For code having duplicate exterior, check the application and check in our models. 50 E52 Safety Precautions Precautions for Correct Use Precautions * Make sure that the protective tubing material is suitable for the sensing object. Otherwise, the Temperature Sensor's protective tubing may be corroded by the sensing object, preventing temperature measurement. * Do not subject the Temperature Sensor's protective tubing to excessive vibration, shock, or weight. Platinum resistance thermometers in particular use extremely fine resistance elements. Using these Temperature Sensors in locations subject to mechanical shock or vibration may result in broken wires. Lead Wire Extension * Platinum Resistance Thermometers Use lead wires for extension with the same resistance and same length for each of the three wires. The resistance of the lead wire will affect the indicated temperature when extended. Therefore, use wires with thick cores. (OMRON does not supply lead wires for extension.) * Thermocouples Always use compensating conductors for thermocouples when extending the lead wires. Use a compensating conductor designed for the connected thermocouple. If you use a different type of compensating conductor from the thermocouple or if you use normal copper wires to extend, correct temperature measurement will not be possible. Also, do not connect positive and negative incorrectly. * Thermistors Use cables with thick core wires for the lead wires used for extension. The lead wires do not have polarity. * Regardless of the type of Temperature Sensor used, resistance to noise will be reduced if the leads are extended. Never extend the lead any further than necessary. Correct Use * Select a location for installing the Temperature Sensor in which the temperature distribution of the sensing object will not change. * Make sure that the length of the Temperature Sensor's protective tubing is sufficient to touch or insert into the sensing object. The length of metallic protective tubing must be at least 20 times its diameter, and the length of non-metallic protective tubing must be at least 15 times its diameter. The insertion length of the special model for packaging machines (E52-CA@AY S@) is 8 mm or longer. * Do not repeatedly bend the Temperature Sensor at the same point. The minimum allowable bending radius of sheathed Temperature Sensors is approximately five times the protective tubing diameter. Bending part of the sensor at an acute angle and then extending again may result in broken internal wires or cracks in the element. Do not bend the soldered sections. The minimum allowable bending radius of the special model for packaging machines (E52-CA@AY S@) is twice the protective tubing diameter. * Do not bend the protective tubing while measuring low temperatures, which will cause the protective tubing to become fragile. * Do not bend sheathed Temperature Sensors to within 100 mm of the end to protect the sensing section. Bending work can be performed on any part that is 8 mm or more from the tip of the special model for packaging machines (E52-CA@AY S@). * Do not allow the temperature of the section connecting the protective tubing and lead wire to exceed 70C for exposed-lead models or 100C for heat-resistive models. The special model for packaging machines (E52-CA@AY S@) can be used at temperatures of up to 260C. * Do not allow the temperature of the terminal box to exceed 100C for exposed-terminal models or 90C for enclosed-terminal models. * Do not subject the ceramic protective tubing of high-temperature thermocouples to sudden heating or cooling. Ceramic protective tubing has a low resistance to thermal shock. Either preheat the protective tubing or gradually heat to the required temperature. * Do not use standard lead wires in locations subject to strong bending stress or on moving parts. * Thermocouples with crimp terminal Use the crimp terimal only as a secondary means of securing the thermocouple. The thermocouple junction of the thermocouple is at the crimped section of the crimp terminals, so a temperature difference occurs between the screw fixating section and the thermocouple junction. Confirm the difference in temperature between the location that is to be measured and the temperature measured by the thermocouple in advance at the actual application temperature. Mounting 1. Install explosion-proof models according to the applicable laws and regulations regarding explosion proofing. 2. Sheathed Temperature Sensors with long protective tubing are coiled for shipping. Straighten the tubing by unwinding it in the opposite direction, without twisting it. 3. Do not excessively bend the section connecting the protective tubing to the lead wires of exposed-lead wires models. Do not insert this section into the sensing object. 4. Do not pull the lead wires with force. Doing so may cause broken wires at the connected section. 5. When measuring at high temperatures that cause the protective tubing to warp, either insert the Temperature Sensor vertically or use an appropriate means to hold the Temperature Sensor in place. 6. To obtain more accurate values, maintain the temperature of the exposed protective tubing to prevent heat loss through heat dissipation. 7. If inductive noise is generated in the Temperature Sensor due to power lines or other source, either change the installation position of the Temperature Sensor and lead wires or provide a shield for the lead wires. 8. Use airtight Temperature Sensors for applications using sensing objects below room temperature, to prevent condensation within the protective tubing and faulty insulation. 9. Do not use the Temperature Sensor in locations that may expose the terminals to water or other liquid. 10.Temperature Sensors are precision devices. Do not subject the Temperature Sensors to shock. Take particular care with products that have ceramic components (ceramic protective tubing, platinum resistance thermometers). 11.Do not use ultrasonic cleaning or otherwise subject platinum resistance thermometers to extreme vibration. Doing so may cause wires to break within a short time. For such environments, consider using sheathed thermocouples, which have a superior vibration-resistant construction compared with platinum resistance thermometers and may be more suitable for the required application, depending on the level of vibration. 12.The life of the protective tubing will be significantly shortened when measuring the temperature of dissolved metals. Select protective tubing material to suit the type of dissolved metal to be measured. 13.Use the following installation methods for applications measuring the temperature of fluids. (a)Install the Temperature Sensor vertically to the flow in tubes with relatively large diameters that enable deep insertion. (b)Install the Temperature Sensor on a diagonal against the flow in tubes with slim diameters that do not enable deep insertion. (c)Install the Temperature Sensor into the convex section of a bend if the tubing diameter is even thinner than in (b). (a) (b) (c) Use an installation design that provides sufficient strength margin. 51 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2018.2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2018 All Right Reserved.