Not recommended for new design Series AM2D-NZ
Use AM2D-Z series 2 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R11.M 1 of 4 North America only11
FEATURES:
Models
Single output
Model Input Voltage
(V)
Output
Voltage
(V)
Output Current
max(mA)
Isolation
(VDC)
Efficiency
(%)
AM2D-0505S-NZ
4.5-5.5
5
400
1000
89
AM2D-0509S-NZ
4.5-5.5
9
222
1000
84
AM2D-0512S-NZ
4.5-5.5
12
167
1000
84
AM2D-0515S-NZ
4.5-5.5
15
134
1000
84
AM2D-1205S-NZ
10.8-13.2
5
400
1000
84
AM2D-1209S-NZ
10.8-13.2
9
222
1000
84
AM2D-1212S-NZ
10.8-13.2
12
167
1000
84
AM2D-1215S-NZ
10.8-13.2
15
134
1000
84
AM2D-2405S-NZ
21.6-26.4
5
400
1000
84
AM2D-2409S-NZ
21.6-26.4
9
222
1000
84
AM2D-2412S-NZ
21.6-26.4
12
167
1000
84
AM2D-2415S-NZ
21.6-26.4
15
134
1000
84
4.5-5.5
5
400
3000
80
4.5-5.5
9
222
3000
81
4.5-5.5
12
167
3000
82
4.5-5.5
15
134
3000
84
10.8-13.2
5
400
3000
80
10.8-13.2
9
222
3000
83
10.8-13.2
12
167
3000
84
10.8-13.2
15
134
3000
85
21.6-26.4
5
400
3000
81
21.6-26.4
9
222
3000
84
21.6-26.4
12
167
3000
85
21.6-26.4
15
134
3000
86
Models
Dual output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
AM2D-0505D-NZ
4.5-5.5
±5
±200
1000
80
AM2D-0509D-NZ
4.5-5.5
±9
±111
1000
84
AM2D-0512D-NZ
4.5-5.5
±12
±83
1000
84
AM2D-0515D-NZ
4.5-5.5
±15
±67
1000
84
AM2D-1205D-NZ
10.8-13.2
±5
±200
1000
80
AM2D-1209D-NZ
10.8-13.2
±9
±111
1000
84
AM2D-1212D-NZ
10.8-13.2
±12
±83
1000
85
AM2D-1215D-NZ
10.8-13.2
±15
±67
1000
84
AM2D-2405D-NZ
21.6-26.4
±5
±200
1000
80
AM2D-2409D-NZ
21.6-26.4
±9
±111
1000
84
AM2D-2412D-NZ
21.6-26.4
±12
±83
1000
84
AM2D-2415D-NZ
21.6-26.4
±15
±67
1000
84
AM2D-0505DH30-NZ
4.5-5.5
±5
±200
3000
82
AM2D-0509DH30-NZ
4.5-5.5
±9
±111
3000
83
RoHS Compliant
Input / Output Isolation 1000, 3000VDC
Low ripple and noise
Operating temperature -40oC to + 105oC
High efficiency up to 89%
Pin compatible with multiple manufacturers
UL94-VO case
7 pin SIP package
Continuous Short Circuit Protection
Click on Series name for product info on aimtec.com
Not recommended for new design Series AM2D-NZ
Use AM2D-Z series 2 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R11.M 2 of 4 North America only11
Models
Dual output (continued)
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
AM2D-0512DH30-NZ
4.5-5.5
±12
±83
3000
85
AM2D-0515DH30-NZ
4.5-5.5
±15
±67
3000
85
AM2D-1205DH30-NZ
10.8-13.2
±5
±200
3000
83
AM2D-1209DH30-NZ
10.8-13.2
±9
±111
3000
84
AM2D-1212DH30-NZ
10.8-13.2
±12
±83
3000
86
AM2D-1215DH30-NZ
10.8-13.2
±15
±67
3000
86
AM2D-2405DH30-NZ
21.6-26.4
±5
±200
3000
84
AM2D-2409DH30-NZ
21.6-26.4
±9
±111
3000
85
AM2D-2412DH30-NZ
21.6-26.4
±12
±83
3000
87
AM2D-2415DH30-NZ
21.6-26.4
±15
±67
3000
87
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
Voltage range
5
4.5-5.5
VDC
12
10.8-13.2
24
21.6-26.4
Filter
Capacitor
Isolation Specifications
Parameters
Conditions
Typical
Rated
Units
Tested I/O voltage
60 sec
1000 and 3000
VDC
Resistance
> 1000
MOhm
Capacitance
60
pF
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See tolerance graph
Voltage balance
Dual output
±1
%
Short Circuit protection
Continuous automatic recovery
Line voltage regulation (Single)
For 1.0% of Vin
±1.2
%
Line voltage regulation (Dual)
For 1.0% of Vin
±1.2
%
Load voltage regulation (Single)
Load 10~100%
±8
%
Load voltage regulation (Dual)
Load 10~100%
±8
%
Temperature coefficient
±0.03
%/oC
Ripple & Noise
At 20MHz Bandwidth
75
mV p-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
100
300
KHz
Operating temperature
-40 to +75
oC
Storage temperature
-55 to +125
oC
Max Case temperature
+105
oC
Cooling
Free air convection
Humidity
95
%
Case material
Plastic UL94-VO
Weight
2.4
g
Dimensions (L x W x H)
0.772 x 0.276 x 0.394 inch 19.60 x 7.00 x 10.0 mm
MTBF
>3 500 000hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Not recommended for new design Series AM2D-NZ
Use AM2D-Z series 2 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R11.M 3 of 4 North America only11
Safety Specifications
Parameters
Agency approvals
Designed to meet
Standards
EN55022 Class B (with recommended circuit)
IEC / EN61000-4-2 Contact
±
6K Criteria B
IEC / EN61000-4-2 Contact ±8K Criteria B
Pin Out Specifications
Pin
1000VDC
3000VDC
Single
Dual
Single
Dual
1
+ V Input
+ V Input
+ V Input
+ V Input
2
- V Input
- V Input
- V Input
- V Input
4
-V Output
- V Output
No pin
No pin
5
No pin
Common
-V Output
-V Output
6
+ V Output
+ V Output
No pin
Common
7
No pin
No pin
+V Output
+V Output
Dimensions
Typical characteristics
Tolerance Envelope Graph
Output Current (%)
Output Voltage (%)
Typical load line
+10%
+5% +2.5%
-2.5%
-7.5%
10%50%100%
Nominal
Voltage
19.60
(0.77)
15.20
(0.60)
2.54
(0.10)
7.00
(0.267)
PRINTED
FACE
0.50
(0.02)
0.50
(0.02) 0.25
(0.01)
1.25
(0.05)
7.00
(0.26)
10.00
(0.39)
9.50
(0.37)
4.10
(0.16)
0.50
(0.02)
NOTE: Unit:mm [inch]
Pin tolerances: 0.10mm [ 0.004inch]
General tolerances: 0.25mm [ 0.010inch]
Not recommended for new design Series AM2D-NZ
Use AM2D-Z series 2 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 051e R11.M 4 of 4 North America only11
Typical EMI Filter
Vin+
Vin-
4.7µF /
50V
LDM
6.8µH
* -470pF /
3KV
*- Optional for 12 & 15V
output Models
Vin+
Vin-
Vo+
Vo-
Load
Aimtec DC/DC
Converter
Derating
-40 - 20 0 20 40 60 80 100
100
80
60
40
20
0
Safe Operating Area
Output Power (%)
85
Ambient Temperature
º C
Free Air Convection
85º
C
105
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available
for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such
applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of
Sale available at www.aimtec.com.