File Name:UHP-500-SPEC 2020-09-29
3.6~4.4V
VOLTAGE ADJ. RANGE Note.7
110~140% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time
90 ~ 264VAC 127 ~ 370VDC
Cold start 30A/115VAC 60A/230VAC
<0.75mA / 240VAC
4.62 ~ 5.46V
-30 ~ +70℃(Refer to “Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
168K hrs min. MIL-HDBK-217F (25℃)
PF 0.95/230VAC PF 0.98/115VAC at full load≥ ≥
12ms/230VAC 12ms/115VAC
±1.0%
±0.5%
±2.0%
200mVp-p
4.2V
UHP-500 -4.2
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
℃
℃ The
The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
ENVIRONMENT
PROTECTION
232*81*31mm (L*W*H)
Protection type :Shut down O/P voltage,re-power on to recover
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
4.85A/115VAC 2.6A/230VAC
RATED POWER
0.905kg; 16pcs/15.48kg/0.82CUFT
47 ~ 63Hz
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.5~5.5V
±1.0%
±0.5%
±2.0%
200mVp-p
5V
11.4~12.6V
±0.5%
±0.3%
±1.0%
200mVp-p
12V
14.3~15.8V
200mVp-p
15V
22.8~25.2V
240mVp-p
24V
34.2~37.8V
360mVp-p
36V
45.6~50.4V
360mVp-p
48V
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
39.6 ~46.8V
13.2 ~ 15.6V
5.75 ~ 6.75V
16.5 ~ 19.5V
26.4 ~ 31.2V
52.8 ~ 62.4V
UHP-500 -5
UHP-500 -12
UHP-500 -15
UHP-500 -24
UHP-500 -36
UHP-500 -48
FUNCTION
REDUNDANT(Optional)
Contact rating(max.):30Vdc/1A resistive load
For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be
automatically enabled. This can prevent the system crash, and provide the reliability of system
DC OK SIGNAL(Optional)
SAFETY STANDARDS
EMC EMISSION
EMC IMMUNITY
Compliance to EN55032,GB/T9254,Class B, EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020
SAFETY &
EMC
(Note.6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020
UL 62368-1,TUV EN62368-1,EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1, EAC TP TC 004 approved;Design refer to EN61558-2-16
80A
336W
80A
400W
41.7A
500.4W
33.4A
501W
20.9A
501.6W
13.9A
500.4W 501.6W
10.45A
UHP-500 series
500W Slim Type with PFC Switching Supply
UHP-500 -55
45~58V
500mVp-p
55V
±0.5%
±0.3%
±1.0%
500W
8.9A
89% 95%
94% 94% 94.5% 95%
90% 95%
60 ~ 69V
INRUSH CURRENT (Typ.)Note9