OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue C 11/2010
Page 3 of 3
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Photologic® Optically Coupled Isolator
OPI125, OPI126, OPI127, OPI127-032, OPI128
Electrical Characteristics (TA = -40o C to +85° C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Diode Input (See OP130 and OP230 for additional information - for reference only)
VF Forward Voltage - - 1.5 V IF = 10 mA, TA = 25° C
IR Reverse Current - - 100 µA VR = 2 V, TA = 25° C
IF(+) LED Positive-Going threshold Current - - 7.5 mA VCC = 5 V, TA = 25° C
IF(+)/IF(-) Hysteresis Ratio - 2.0 - - -
Photologic® Output (See OP800 and OP801 for additional information - for reference only)
VCC Operating Supply Voltage 45 - 5.5 V -
ICC Supply Current - - 20 mA VCC = 5.5 V, IF = 0 or 7.5 mA
VOL
Low Level Output Voltage
OPI125
OPI126
OPI127
OPI128
-
-
-
-
-
-
-
-
0.40
0.40
0.40
0.40
V
VCC = 4.5 V, IOL = 13 mA, IF = 0 mA
VCC = 4.5 V, IOL = 13 mA, IF = 0 mA
VCC = 4.5 V, IOL = 13 mA, IF = 7.5 mA
VCC = 4.5 V, IOL = 13 mA, IF = 7.5 mA
VOH
High Level Output Voltage
OPI125
OPI127
2.4
2.4
-
-
-
- V
VCC = 4.5 V, IOH = -800 µA, IF = 7.5 mA
VCC = 4.5 V, IOH = -800 µA, IF = 0 mA
IOS
Short Circuit Output Current
OPI125
OPI127
-20
-20
-
-
-120
-120
mA
VCC = 5.5 V, IF = 7.5mA, Output = GND
VCC = 5.5 V, IF = 0 mA, Output = GND
IOH
High Level Output Current
OPI126
OPI128
-
-
-
-
100
100
µA VCC = 4.5 V, VOH = 30 V, IF = 7.5 mA
VCC = 4.5 V, VOH = 30 V, IF = 0 mA
tr, tf
Output Rise Time, Output Fall Time
OPI125, OPI127 - 100 -
ns
VCC = 5 V, TA = 25° C,
IF = 0 or 10 mA, f = 10 kHz,
D.C. = 50%, RL = 8 TTL loads
Output Rise Time, Output Fall Time
OPI126, OPI128 - 100 -
VCC = 5 V, TA = 25° C,
IF = 0 or 10 mA, f = 10 kHz,
D.C. = 50%, RL = 360 Ω
tPLH, tPHL
Propagation Delay, Low-High, High-Low
OPI125, OPI127 - 5 -
µs
VCC = 5 V, TA = 25° C,
IF = 0 or 10 mA, f = 10 kHz,
D.C. = 50%, RL = 8 TTL loads
Propagation Delay, Low-High, High-Low
OPI126, OPI128 - 5 -
VCC = 5 V, TA = 25° C,
IF = 0 or 10 mA, f = 10 kHz,
D.C. = 50%, RL = 360 Ω
Notes:
(1) Measured with input and output leads shorted in air with a maximum relative humidity of 50%. If suitably encapsulated or oil-
imm
r
th
i
l
ti
n v
lt
i
in
r
t
2
kV minim
m.