CORCOM Product Guide Two-Stage General Purpose RFI Power Line Filter R Series VR7/ER7 VR3/ER3 UL Recognized CSA Certified VDE Approved 10VR6 VR1/ER1 R Series Specifications The dual T section RFI power line filters provide premium performance at moderate cost. They are well suited for low impedance loads where noisy RFI environments are present. They control pulsed, continuous and/or intermittent interference, providing protection to your equipment from power line noise in addition to protecting the line from equipment noise. The R series dual T type provides low leakage current without deterioration of insertion loss characteristics and at a competitive cost. The ER models meet the low leakage current requirements of VDE portable equipment, and (120 Volt) UL2601 non-patient medical equipment. Maximum leakage current,each line-to-ground VR Models @ 120 VAC 60 Hz: .4 mA @ 250 VAC 50 Hz: .7 mA Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Rated voltage (max.): LINE LOAD Resistor location for reference only. 2250 VDC 1450 VDC 50/60 Hz 250 VAC Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Rating Electrical Schematic ER Models .21 mA .36 mA Frequency-MHz 1 5 10 .15 .5 VR Models 1A, 3A 2A, 5A, 10A, 20A 30 30 5 65 44 65 60 65 65 65 65 65 60 ER Models 1A, 3A 2A, 5A, 10A, 20A 25 2 60 35 65 51 65 63 65 60 65 50 Frequency-MHz 10 5 1 30 Line-to-line in 50 ohm circuit Current Rating Case Style 20VR6 Note: Same layout for 20VR1 and 20ER1, except .250 [6.35] (5) terminals replace Screw Terminals of 20VR6. Terminals: No. 8-32 (5) Slots: .250 x .156 (4) 6.35 3.96 VR, ER Models 1A, 3A 2A, 5A, 10A, 20A .15 .5 - - - - 65 35 60 60 54 57 46 45 E D B 2.00 50.8 A C Torque 18 2 in.lb 84 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Two-Stage General Purpose RFI Power Line Filter (Continued) R Series Case Dimensions R1 (except 20 Amp) Part No. B D E A C Typical dimensions: Terminals: .250 [6.35] (5) Holes: .07 [1.8] Dia.(4) Mounting Holes: .188 [4.78] Dia. (2) Slot: .07 x .16 [1.8 x 4.1] R3 Blue Blue Brown B Brown A D E Typical dimensions: Wire leads: 4.0 [101.6] Min. 10VR6 Green/ Yellow 1VR1, 1ER1, 2VR1, 2ER1 1VR3, 1ER3, 2VR3, 2ER3 3VR1, 3ER1, 5VR1, 5ER1 3VR3, 3ER3, 5VR3, 5ER3 3VR7, 3VR7M, 3ER7, 3ER7M 5VR7, 5VR7M, 5ER7, 5ER7M 10VR1, 10ER1 10VR3, 10ER3 C 10VR6 Mounting Holes: .188 [4.78] Dia. (2) Terminals: No. 8-32 (5) 10VR7, 10VR7M, 10ER7, 10ER7M 20VR1, 20ER1 20VR6 A B (max) (max) C (max) 3.35 85.1 2.07 52.6 3.85 97.8 2.56 65.0 4.33 110.0 4.33 110.0 3.85 97.8 2.56 65.0 3.96 100.6 4.33 110.0 5.23 132.8 1.16 29.5 1.16 29.5 1.16 29.5 1.16 29.5 1.28 32.5 1.28 32.5 1.53 38.9 1.53 38.9 1.53 38.9 1.53 38.9 1.53 38.9 1.81 46.0 1.81 46.0 2.07 52.6 2.07 52.6 2.25 57.2 2.25 57.2 2.07 52.6 2.07 52.6 2.07 52.6 2.25 57.2 3.37 85.6 D 2.375 60.33 2.375 60.33 2.938 74.63 2.938 74.63 1.575 40.01 1.575 40.01 2.938 74.63 2.938 74.63 2.938 74.63 1.575 40.01 3.75 95.25 C 2.78 70.6 2.78 70.6 3.35 85.1 3.35 85.1 0.64 16.3 0.64 16.3 3.35 85.1 3.35 85.1 3.35 85.1 0.88 22.4 4.20 106.7 .02 [.5] B D E A E (max) .015 .38 Part Numbers Mounting holes .188 [4.78] Dia. (2) Torque: 18 2 in.lb R7 & R7M (with metric insert) Tapped insert: No. 6-32 x 1/4 (2)-R7 No. M-3 x .5 (2)-R7M D B A E .235 R 5.96 C .157 Dia. (2) 3.98 .910 23.11 1.295 32.89 1.575 40.01 Typical dimensions: Holes: .07 [1.8] Dia.(4) Terminals: .250 [6.35] (5) Mounting Holes: .188 [4.78] Dia. (2) Slot: .07 x .16 [1.8 x 4.1] Panel Cutout (back mount) Tolerance .005 [0.13] 01VR1 01VR3 02VR1 02VR3 03VR1 03VR3 03VR7 03VR7M 05VR1 05VR3 05VR7 05VR7M 10VR1 10VR3 10VR6 10VR7 10VR7M 20VR1 20VR6 Line Cord (R7/R7M): 01ER1 01ER3 02ER1 02ER3 03ER1 03ER3 03ER7 03ER7M 05ER1 05ER3 05ER7 05ER7M 10ER1 10ER3 10ER7 10ER7M 20ER1 GA400 85 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com RFI Power Line Filters Case Styles