Sensor & Wire-saving Link System SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop WIRE-SAVING SYSTEMS S-LINK `T'-branch Multi-drop System Enabling Flexible Cable Layout Marked Conforming to EMC Directive (Except some components) Till now Many wires, high cost, and yet miswiring. (Point-to-point wiring) Cylinder Photoelectric sensor Inductive proximity sensor Limit switch Fiber sensor Lamp Manifold electromagnetic valve Solenoid From now on `T'-branch S-LINK saves wires throughout the layout! (Tree architecture) Moreover, wiring and maintenance is significantly simplified. 7 7 6 6 5 5 4 4 3 3 2 2 1 `T'-branch 26 1 0 0 Space-effective Quick construction The use of wires is greatly reduced and the number of connecting terminal blocks is minimized, resulting in large reduction in cost, as well as, the waste generated during wiring. The layout of devices becomes flexible and the design is easier due to the `T'-branch multi-drop wiring. Since the wiring is simple, miswiring is also sharply decreased. Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW Wire-saving Three concepts of S-LINK FP3 SL7 7 6 5 5 4 3 3 2 2 1 1 0 0 0 7 6 6 5 7 6 5 4 Electrical works cost Electrical works Machinery cost Construction cost 6 5 4 3 1 7 The time required for equipment wiring is greatly reduced, contributing to reduction in electrical works cost. Further, design and maintenance personnel expenses are also sharply decreased. 7 6 4 2 5 4 4 3 3 2 2 1 1 0 0 7 6 5 4 7 6 5 4 3 3 3 2 2 1 1 1 0 0 0 2 Sensors can be easily connected with plug-in connection. The addition of an I/O output device is easy. Construction can be done in a short time. * Connection by plug-in unit * Connection by connector Large cost saving 7 6 5 4 3 2 1 Machinery cost The control box can be of smaller size since connecting terminal blocks are not needed. 0 S-LINK devices are compact. Hence, the control box can be mounted in a tight space. WIRE-SAVING SYSTEMS S-LINK It contributes to the miniaturization of the machine due to reduced wiring space. 27 S-LINK Transmits 128 I/Os on Two Signal Lines and Realizes `T'-branch Multi-drop Wiring (Tree Architecture) S-LINK enables transmission of 128 I/Os of sensors, switches, or actuators on two signal lines up to 200m (400m with the booster). The S-LINK lines can be branched off in any direction, at any point, so that a flexible cable layout is possible. The original SUNX signal processing enables highly reliable `T'-branch multi-drop wiring. SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop WIRE-SAVING SYSTEMS S-LINK Max. 128 I/Os Two signal lines Two power lines Ma x. 2 7 7 6 6 5 00m `T'-branch multi-drop 5 4 4 3 3 2 2 1 1 0 0 Caution: The connectable I/O number might decrease from 128 points depending upon the type of devices and their place of connection. Highly Reliable Signal Transmission * The loop wiring maintains the signal transmission over the entire system even if the loop may break at any one place. * If the cable breaks somewhere, the controller finds out the addresses of all disconnected units, and displays their first address. Specifying error addresses shortens the repairing time. No problem if the cable breaks at any one place. * The S-LINK system automatically turns its power off when excess current flows through the signal lines due to a short-circuit. * The double code collation makes the signal transmission secure and reliable. * S-LINK's unique signal transmission, large voltage amplitude (0 24V) and wide pulse width (35!s) provide high noise immunity. The signal transmission time is 5ms approx. for 32 points, or 11ms approx. for 128 points. S-LINK controller SL-CU1A Address display SL-CU1A Address No.0 Address No.1 In case the cable breaks here, the controller indicates Address No.1. Easy Input/Output Check * Since the S-LINK system can operate even when the PLC is disconnected, the system construction time can be drastically reduced by parallel development of the software (PLC program) and the hardware (equipment assembly, I/O device check). Further, in case of an error, it can be immediately found whether the error is on the PLC side or the I/O device side. * A handy monitor which can check I/O devices is available. The handy monitor can be hooked up to the S-LINK signal transmission lines at any place. I/O states can be checked in batches of 16. The handy monitor is also incorporated with the S-LINK controller functions, so that, for example, it can perform an I/O check on conveyor system segments, still under assembly, even without the S-LINK controller. Checking inputs/ outputs is easy. The S-LINK system can be independently operated without the PLC. Handy monitor SL-HM1 Note: Although, SL-HM1 incorporates the functions of the SL-CU1A controller, PLC I/O connectors cannot be connected. 28 * Connectable to terminal block type PLC * Multi-core cable PLC I/O units SL-S, SL-SP, SL-P, SL-PP are connectable to terminal block type PLCs. * Easily connectable to different manufacturers' PLCs * PLC I/O connectors SL-S, SL-P are one-touch connectable to different manufacturers' PLC I/O modules. I/O modules of different manufacturers' terminal block type PLCs I/O modules of different manufacturers' PLCs PLC I/O connectors SL-CU1A Multi-core cable SL-CU1A I/O data I/O data To S-LINK system Multi-core cable PLC I/O unit To S-LINK system Connectable PLC manufacturers * Matsushita Electric Works * Mitsubishi Electric Corp. * Omron Corp. * Yokogawa Electric Corp. * Sharp Corp. * Fuji Electric Works * Hitachi * Yasukawa Electric Corp. * Toshiba Corp. * Toshiba Machine Co. m Please refer to P.44 for the connectable PLCs of each manufacturer. Suitable for PLC Bus * Direct connection to PLC bus * S-LINK controller for direct connection to Matsushita Electric Works' PLC FP3/FP10SH/FP10S bus line or Yokogawa Electric's PLC FA-M3 series bus line, and S-LINK control boards for direct connection to the bus line of Matsushita Electric Works' board type PLC, FP-C or Sharp's board type PLC, J-board Z-300 series, are available. Since they incorporate the S-LINK control functions and the PLC I/O connector functions, large cost and space savings are achieved. For Matsushita Electric Works PLC FP3/FP10SH/FP10S SL-FP3 For Yokogawa Electric PLC FA-M3 series SL-FAM3 For Matsushita Electric Works PLC FP-C SL-FPC In case Matsushita Electric Works PLC bus S-LINK controller SL-FP3 is used. Normal construction Construction using SL-FP3 PO WE PO WE R R CP U CP U IN6 4X SL- OU SP3 T64 Y One slot is occupied Two slots are occupied IN6 OU 4X This space is also not necessary ! SL-FP3, alone, is sufficient T64 Y PLC I/O connector Module for intput Module for output S-LINK controller For Sharp J-board Z-300 series SL-Z300 Suitable for Personal Computers * Direct connection to personal computers * As control by personal computers has spread in recent years, S-LINK control boards for direct connection to PCI bus, PC/AT and compatibles (ISA bus) and to NEC PC/FC-98 series (C bus) have been developed, in order to enable control of the S-LINK system by a personal computer. Further, S-LINK control board for direct connection to the VME bus line is also available. Flexibility in design has been increasingly improved. For VME bus SL-VMES2 For PC/AT SL-PCAT For PCI SL-PCI 128 I/Os can be controlled by just two signal lines! `T'-branch 7 6 5 4 3 2 1 0 For PC/FC-98 series SL-PC98 Loop wiring is also possible! 29 WIRE-SAVING SYSTEMS Suitable for Various PLCs Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK WIRE-SAVING SYSTEMS SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop S-LINK Compatible with Global Fieldbus Networks Globally, fieldbus networks for FA are spreading rapidly to realize wire-saving connections between PLCs of different manufactures, or high performance devices, such as, temperature controllers, graphic panels etc. SUNX has developed gateway controllers which enable connection of S-LINK to the fieldbus networks being used in different parts of the world. Hence, wire-saving connections and other advantages of S-LINK can be realized even when using fieldbus networks. JPCN-1/RS-485 For Device Net SL-GU1-D For PROFIBUS-DP SL-GU1-P For INTERBUS SL-GU1-I For CC-link SL-GU1-C For JPCN-1/RS-485 SL-CU1-485 Suitable devices for different manufacturers' fieldbus networks Graphic panel Temperature controller etc. Master unit made by different PLC manufacturers High performance devices are connected by wire-saving fieldbus network Sensor & wire-saving link system S-LINK ON/OFF devices are connected by quick construction, wiresaving S-LINK system S-LINK gateway controller S ES DR AD F OF K. CH B0 T B1~ 31 OU 0 63 32~ 95 64~ 127 96~F OF ON N RUS. SYD. AD IN . AT ST T SE ND SE 1 ER 3 ER 4 ER BK D ID ON 0 EWA -G Y CON TRO U1 LLE R -D AN JAP 05 N8Q 7 6 5 Easy connection and neat wiring by `T'-branches using hook-up connectors 4 1 0 32 16 8 4 2 1 ID F OF ON G 24 0 S-LI NK GAT SL EWA -G Y CON TRO U1 LLE R -D AN JAP 05 N8Q 7 6 5 4 3 3 2 2 1 1 0 0 Max. 128 I/O channels connectable per S-LINK gateway controller 30 RD D G A 24 0 F OF G GAT WH B TE 24 0 24 NK BK BU I. SH 4 ER 1 0 32 16 8 4 2 1 A 24 0 SL T SE ND SE 1 ER 3 ER BU I. SH RD B TE 24 0 S-LI IN WH G S ES DR AD F OF K. CH B0 T B1~ 31 OU 0 63 32~ 95 64~ 127 96~F OF ON N RUS. SYD. AD . AT ST * Seamless connection to fieldbus networks * S-LINK can be connected seamlessly to fieldbus networks using the S-LINK gateway controllers. * Advanced wire-saving connection with S-LINK and fieldbus networks * Wire-saving connections can be realized even when using fieldbus networks. An efficient wire-saving network can be implemented by connecting distributed bit level data I/O devices, such as, sensors, switches, etc., by S-LINK. m Advantage of using with higher level networks Since the higher level networks mostly use cascade wiring with shielded twisted pair cable, the flexibility in wiring and wiring operations have not improved. In S-LINK, `T'-branch flexible layout can be realized using different types of quick connecting hook-up connectors, and distributed ON/OFF data devices, such as, switches, sensors, etc., can be efficiently wired. In this manner, an exceedingly efficient wire-saving link system can be realized in combination with higher level networks. * Long distance transmission The max. transmission distance is as follows. DeviceNet: 500m, PROFIBUS-DP and CC-Link: 1,200m, INTERBUS: 13km, JPCN-1/RS-485: 1,000m. S-LINK can transmit up to 400m using the booster (SL-BS1A). Hence, a system of total 1,600m can be constructed with PROFIBUS-DP or CC-Link (DeviceNet: 900m, INTERBUS: 13.4km). * Total I/O channels 8,064 Nos. Up to 99 Nos. of S-LINK gateway controllers can be connected as slaves to one PROFIBUS-DP master unit [DeviceNet: 63 Nos., INTERBUS: 256 Nos., JPCN-1/ RS-485: 31 Nos., CC-Link: 32 Nos. (Note 2)]. Since max. 128 Nos. I/O devices can be connected to one S-LINK gateway controller, I/O signal of total 12,672 channels [DeviceNet: 8,064 channels, INTERBUS: 4,096 channels (Note 3), JPCN-1/RS-485: 3,968 channels, CC-Link: 2,048 channels (Note 2)] can be transmitted. Notes: 1) The total No. of I/O channels may be less than the maximum No. mentioned above depending on the master unit capacity. Also, the No. of devices connectable to the S-LINK system may be less than 128 Nos., depending on the type of devices and places connected. Notes: 2) In case of the S-LINK gateway controller for CC-Link, the No. of controllable I/O channels varies with the No. of units connected to CC-Link. Notes: 3) For INTERBUS, one master unit can control up to 4,096 I/O channels only. * Personal computer can be used as master (for JPCN-1/RS-485) * PC/AT or compatible (ISA bus), NEC PC/FC-98 series personal computer or PC/104 bus board can be used as a master unit. Long distance and multi-point control is easily possible with a personal computer when the JPCN-1/RS-485 master board and the S-LINK gateway controller for JPCN-1/RS-485, SL-CU1-485, are used. Master board for personal computer SL-PCAT-485 SL-PC98-485 SL-PC104-485 S-LINK gateway controller SL-CU1-485 To S-LINK system Direct hook-up!! Master board for PC/AT SL-PCAT-485 Master board for PC/FC-98 series SL-PC98-485 Master board for PC/104 bus SL-PC104-485 Communication can be easily done in S-LINK mode. (Communication can also be done in JPCN-1 mode.) * The master boards for personal computers can be used in the following two modes: * 1 S-LINK mode (using RS-485 communication) * 2 JPCN-1 mode (Please arrange a driver software separately, when using the JPCN-1 mode.) 31 WIRE-SAVING SYSTEMS S Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK WIRE-SAVING SYSTEMS SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop S-LINK I/O Unit Selectable According to the Application 2 Channel I/O Unit SL-CH21, SL-CH21-PN, SL-CH21K 1 Channel I/O Unit SL-CH1, SL-CH1-PN * Different devices can be simply connected at any place * SL-CH1(-PN) can be used as either an input unit or an output unit by switch selection. Hence, a sensor, limit switch, etc., is connectable when it is used as an input unit, and a relay, lamp, etc., is connectable when it is used as an output unit. It can be connected by a `T'-branch at any place on the S-LINK cable. * Both input and output devices are connectable * SL-CH21(-PN) allows connection of one input and one output device. It is useful for a mechanism using both input and output devices. * SL-CH21K, isolation type for power supply remote control function of NEC FA personal computer FC-98/FC98-NX series, is also now available. Application Application Sensor or relay Cylinder with electromagnetic valve It handles either the input signal from a sensor or the output signal to a relay. It handles both the input signal from a cylinder switch and the output signal to an electromagnetic valve. Cylinder switch Sensor or Relay Electromagnetic valve 2 Channel Input Unit SL-CH20, SL-CH20-PN 2 Channel Output Unit SL-CH22, SL-CH22-PN * Two input devices are connectable * SL-CH20(-PN) allows connection of two input devices, and handles both signals. It contributes to cost-effectiveness if you use several input devices. * Two output devices are connectable: drive current 100mA max. each * SL-CH22(-PN) allows connection of two output devices, and handles both signals. It can supply 100mA max. current to each device, so that ordinary DC relays or solenoid valves can be activated. Application Application Sensor and limit switch Beacon and relay It handles two input signals from a sensor and a limit switch, two sensors, or two limit switches. It handles two output signals to a beacon and a relay, two relays, or two solenoid valves. Sensor Beacon Relay Limit switch I/O Arrayed Terminal Unit SL-TB, SL-TB-PN, SL-TBP, SL-TBP-PN, SL-TBP-TY * Screw-on terminal unit * Depending upon the model, 4 Nos., 8 Nos. or 16 Nos. of input/output devices (NPN/PNP type) can be connected to the terminal units. Further, since power supply terminals for the input/output devices have been incorporated on all terminal units, neat wiring is possible. * Output signal hold * The output arrayed terminal unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission lines. This limits the effect on an output device, should a failure occur. * Separate load power supply type output terminal is now available * Separate load power supply type output terminal SL-TBP-TY which enables forced turning OFF of the output device connected to the output terminal without halting the complete S-LINK system, by switching off the load power supply, in the event of the output device failure, is now available. 32 * High resolution * A high resolution of 1/4,000 (12 bits) can be realized. * Fast data conversion * They have a fast data conversion time of 1ms approx., for analog to digital, or digital to analog. * Input range settable for each channel (SL-TBAD4) * In case of the analog input arrayed terminal unit SL-TBAD4, it is possible to set the input range for each input channel. As the analog input range can be 4 to 20mA, 1 to 5V, 0 to 10V or10 to10V, it can be selected according to the output of the connected analog device. Environment Resistant I/O Unit SL-TW4, SL-TW4-PN, SL-TW8, SL-TW8-PN, SL-TW2P2, SL-TW2P2-PN, SL-TWP4, SL-TWP4-PN * Reliable design with IP67 protection * It has IP67 (IEC 60529) protection, which makes it safe even against water splashes. Besides wire-saving in equipment/machinery which requires waterproofing, it can be used to simplify construction at places where so far `water-resistant box cable groundterminal block', etc., were used. * Wide variety * Four types of units are available: input unit (4 or 8 inputs), I/O unit (2 inputs and 2 outputs), or output unit (4 outputs). * Easy wiring with exclusive water-resistant connector * M12 composite 4-pin connectors having IP67 protection are available for connection of the main cable, branch cables or I/O devices. Troublesome soldering is absolutely not required, and cables of I/O devices can be connected simply by a screwdriver. Four types of composite male connectors are available to suit the cable diameter of different I/O devices. Further, a branch connector which can not only branch the main cable easily, but can also connect a set of emitter/receiver of a thru-beam type photoelectric sensor (1 set) as 1 input channel, is available. * `T'-branch wiring and cascade wiring possible * Main cable and branch cable can not only be `T'-branched, but can also be cascade wired. <`T'-branch wiring> IN side Cover for M12 male connector (SL-WPK) (Optional) Branch connector (SL-WY)(Optional) IN side Cover for M12 male connector (SL-WPK) (Optional) IN side OUT/ LOCAL PWR side IN side OUT/ LOCAL PWR side Branch connector (SL-WY)(Optional) 33 WIRE-SAVING SYSTEMS Analog I/O Arrayed Terminal Unit SL-TBAD4, SL-TBDA1 Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK I/O Unit Selectable According to the Application Relay Output Terminal Unit SL-TPR4, SL-TPR8 * Output signal hold * The relay output terminal unit is incorporated with an output signal hold function, which retains the output state just before an error occurs on the signal transmission lines. This limits the effect on an output device, should a failure occur. * Output device control through relays * These are 4 channel and 8 channel relay output terminal units. The integrated relay can drive AC actuators up to 250V 2A. SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop WIRE-SAVING SYSTEMS S-LINK On-board I/O Module SL-M, SL-MP * I/O interface for custom made PCB * These are IC type modules with external address setting switches and indicators. The modules are available as vertical mounting type and horizontal mounting type. Selection can be made depending upon the custom PCB design and the component space available. Mounted PCB illustration Vertical mounting type Horizontal mounting type Custom made printed circuit board To S-LINK and I/O devices Terminal block 8 Channel Snap-connector I/O Unit SL-T8J, SL-T8J-PN, SL-TP8J, SL-TP8J-PN * 8 input devices or 8 output devices are connectable * The slim and compact snap-connector I/O unit interfaces 8 input devices or 8 output devices with the S-LINK system. Its connections are very easy with the snap male connectors (optional). 8 channel snap-connector input unit SL-T8J(-PN) 8 channel snap-connector output unit SL-TP8J(-PN) 7 Snap male connector (Optional) SL-CP1, SL-CP2 or SL-CP3 6 5 4 I/O device cable 3 2 * Output signal hold * The 8 channel snap-connector output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission lines. This limits the effect on an output device, should a failure occur. * Snap male connector * SL-CP1, for 0.08 to 0.2mm2 conductors, SL-CP2, for 0.3mm2 conductors, and SL-CP3, for 0.5mm2 conductors, clamp the inner conductors of a cable, and establish conduction simply by pressing, so that there is no need to strip the wire insulation. 1 0 35mm width DIN rail I/O device cable SL-CP1 or SL-CP2 34 I/O device cable SL-CP3 * 16 I/Os connectable via a MIL connector * The slim and compact MIL connector I/O unit connects 16 input/output devices to the S-LINK system by a 20-pin MIL connector. 16 channel MIL connector input unit SL-T16C1(-PN) 16 channel MIL connector output unit SL-TP16C1(-PN) 20-pin MIL connector (male receptacle) MIL-C-83503 conforming AXM220001 manufactured by Matsushita Electric Works 20-pin MIL connector (female connector)(Optional) AXM120415 manufactured by Matsushita Electric Works or equivalent 20-core flat cable (Optional) ( ) ( * Matsushita Electric Works relay terminals are connectable with MIL connector cables (SL-T16C1 only) * RT2 relay terminal (AY23), PC relay terminal (AY11)/PC terminal (AY10), or CT-2 connector terminal (AYC) manufactured by Matsushita Electric Works are directly connectable via a MIL connector cable as the pin arrangements match. ) RT-2 relay terminal manufactured by Matsushita Electric Works (AY23) 35mm width DIN rail (Optional) * Output signal hold * The 16 channel MIL connector output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission lines. This limits the effect on an output device, should a failure occur. 16 inputs or 16 outputs Snap-connector Sensor Block SL-BMJ, SL-BXJ * Max. 16 input devices are connectable * The snap-connector sensor block (main or extension) interfaces maximum 16 input devices, such as, sensors or switches, to the S-LINK system. Their connections are very easy with the snap female connectors (optional). Snap female connector SL-CJ1 (for 0.08 to 0.2mm2 conductors) SL-CJ2 (for 0.3mm2 conductors) Removable cover Input device cable 3 2 8 1 7 6 5 Suitable for DIN rail 8 1 7 6 5 4 Operation indicators Extension block SL-BXJ 4 3 2 It can be `T'-branched on the S-LINK cable Extension connector Sensor main block SL-BMJ * Snap female connector * SL-CJ1, for 0.08 to 0.2mm2 conductors, and SL-CJ2, for 0.3mm2 conductors, clamp inner conductors of a cable, and establish conduction 124V simply by pressing, so that there is 20V no need to strip the wire insulation. 3Sensing output 4Self-diagnosis output * Combination with plug-in unit sensor blocks * The snap-connector sensor block (main or extension) is combinable with the plug-in unit sensor block (main or extension). ( SL-BMJ can be followed by two SL-BXs. SL-BM can be followed by one SL-BXJ. ) Plug-in Unit Sensor Block SL-BM, SL-BX * Plug-in units * The following sensor units can be plugged in on the sensor block. * Max. 16 sensors are connectable * One plug-in unit sensor main block can be followed by max. three extension blocks, so that max. 16 plug-in units are connectable. Plug-in units Amplifier-separated Input terminal unit (Note 2) Fiber sensor * Digital setting (Note1) photoelectric sensor SL-TJ1 SU-7J FX-D1J (Red LED) Photoelectric * Auto-setting sensor FX-A1J (Red LED) Inductive proximity sensor FX-A1GJ (Green LED) Limit switch * Manual setting FX-M1J (Red LED) Amplifier-separated inductive proximity FX-M1GJ (Green LED) sensor GA-14J Various input devices GA-15J are connectable Extension block (SL-BX) three extension ( Max. blocks are connectable. ) Sensor main block (SL-BM) The sensor blocks can generate the ORed self-diagnosis output of all the connected sensors. But, in this case, the first channel of the sensor main block gets occupied. Notes: 1) In case the digital setting fiber sensor FX-D1J is connected to the plug-in unit sensor block, Output 2 cannot be used. Notes: 2) PNP output type sensor cannot be connected to input terminal unit SL-TJ1. 35 WIRE-SAVING SYSTEMS 16 Channel MIL Connector I/O Unit SL-T16C1, SL-T16C1-PN, SL-TP16C1, SL-TP16C1-PN Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK I/O Unit Selectable According to the Application S-LINK Direct Hook-up Photoelectric Sensor SL-A * Direct hook-up to S-LINK cable * The sensor SL-A can be hooked up to the S-LINK cable without any interface. SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop * All four types are available Thru-beam type SL-A11, SL-A13 10m (Infrared) 30m (Infrared) Retroreflective type SL-A19 5m (Red, with polarizing filters) * No interference * A total of 128 sensors can be connected in one S-LINK system without any interference. * Note: If sensors are mounted next to each other, their Diffuse reflective type SL-A12 700m (Infrared) addresses should be separated by 4, or more. S-LINK Direct Hook-up Area Sensor SL-N15 SL-CH21 DR ON ES T NO ED US 1 2 4 64 S XS L-C U N H X 21 ND 8 16 OF F 32 AD S * Direct hook-up to S-LINK cable Conventional * The area sensor SL-N15 can be hooked up to the S-LINK cable without any interface. Conventionally, NA1-5 has been interfaced by SL-CH21 with three branch points, but SL-N15 allows you to hook up the emitter and the receiver to the S-LINK cable, without any interface. SL-N15 E SID IN I/O :G OU T :R SE WIRE-SAVING SYSTEMS S-LINK NA1-5 One-touch hook-up at any place. SL-N15 Booster SL-BS1A * Cable extension to total 400m * The booster extends the S-LINK cable by 200m, to a total 400m length. Loop wiring is also possible beyond the booster. 1 Total 400m in series 200m 3 Satellite loops around main loop 200m Controller Booster Booster 2 200m extension from a branch point Controller 200m Controller Booster Booster Booster 200m 200m 200m Booster Booster Notes: 1) Cable extension may not be possible depending on the type and number of I/O devices connected. Notes: 2) A maximum of seven boosters can be connected for one S-LINK control unit. However, one booster can never be followed by another booster in series. 36 S-LINK Hook-up Connector SL-J1A, SL-JK, SL-JK1, SL-J3A, SL-JE, SL-JE-RC * Simple hook-up * No need to connect a cable on a terminal with screws. Wire insulation stripping, and crimp contact fitting have been inevitable until the S-LINK hook-up connector was introduced. Using the hook-up connector saves your time and space, and enables a flexible cable layout. * Socket-branch hook-up connector SL-JK and SL-JK1 * By connecting the socket-branch hook-up connector SL-JK and SL-JK1 to the S-LINK cable and using the snap male connector SL-CP, S-LINK devices can be connected very easily. They can also be disconnected easily when required. Illustration of connected S-LINK devices S-LINK branch cable Cover SL-CP2 (Black) for 0.3mm2 conductors ( Just hook-up both covers, each holding an S-LINK cable, and the housing together. Sensor block SL-BM ) SL-JK1 (Blue) (for `T'-branch) Housing Cover S-LINK main cable S-LINK direct hook-up photoelectric sensor SL-A Sensor block SL-BMJ m Use exclusive S-LINK cables. * Cable end connector optimum for cable termination available * When cabtyre cable is used as the main cable, the end connector can be easily connected. I/O arrayed terminal unit (SL-TB, SL-TBP) S-LINK exclusive cabtyre cable (SL-CBM100, SL-CBM200) Junction terminal block (commercial product) Cable attached end connector (SL-JE-RC) Cable attached end connector (SL-JE-RC) S-LINK exclusive cabtyre cable (SL-CBM100, SL-CBM200) 2 channel I/O unit SL-CH21 Snap Connector SL-CJ1, SL-CJ2, SL-CJ12, SL-CJ22, SL-CP1, SL-CP2, SL-CP3, SL-CP12, SL-CP22 * Wire clamping in a snap * SL-CJ1, for 0.08 to 0.2mm2 conductors, and SL-CJ2, for 0.3mm2 conductors, are used with SL-BMJ or SL-BXJ. SL-CP1, for 0.08 to 0.2mm 2 conductors, SL-CP2, for 0.3mm2 conductors, and SL-CP3, for 0.5mm2 conductors, are used with SL-T8J(-PN) or SL-TP8J(-PN) I/O unit and SL-JK or SL-JK1 hook-up connector. Further, if SL-CP3 is used, S-LINK I/O devices can be easily connected/disconnected from the main/branch cable. Moreover, 2-pin type hook-up female connectors SL-CJ12 (for 0.08 to 0.2mm2), SL-CJ22 (for 0.3mm2) and 2-pin type hook-up male connectors SL-CP12 (for 0.08 to 0.2mm 2), SL-CP22 (for 0.3mm2) are also available for extension of 2-wire I/O devices. Wire clamping is easy. Just insert wires of the cable into the specified holes of the connector and press. There is no need to strip the wire insulation. Snap female connector <4-pin type> S-LINK Exclusive Pliers SL-JPS, SL-JPD, SL-JPE, SL-JPC * Fastening of hook-up connector is simple and reliable * The S-LINK exclusive pliers make wiring with hook-up connectors simple and reliable. The spring slide-back mechanism improves the productivity. Ratchet mechanism type SL-JPD is also available. Snap male connector <4-pin type> SL-CJ1 or SL-CJ2 I/O device cable SL-CP1 or SL-CP2 I/O device cable I/O device cable SL-CP3 <2-pin type> <2-pin type> I/O device cable SL-CJ12 or SL-CJ22 I/O device cable SL-CP12 or SL-CP22 37 WIRE-SAVING SYSTEMS Simple Construction Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK WIRE-SAVING SYSTEMS SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop S-LINK Simple Construction Water-resistant Connector SL-WP4, SL-WP5, SL-WP6, SL-WP8, SL-WJ8, SL-WY, SL-WE * Easy wiring with exclusive water-resistant connector * M12 composite 4-pin connectors having IP67 protection are available for connection of the main cable, branch cables or I/O devices. Troublesome soldering is absolutely not required, and cables of I/O devices can be connected simply by a screwdriver. Four types of composite male connectors are available to suit the cable diameter of different I/O devices. Further, a branch connector which can not only branch the main cable easily, but can also connect a set of emitter/receiver of a thru-beam type photoelectric sensor (1 set) as 1 input channel, is available. * Branching of main/branch cable possible * A branch connector which can be used to branch the main/branch cable is available. Moreover, it can connect a set of emitter/receiver of a thru-beam type photoelectric sensor as 1 channel. * Environment resistant end connector available * It is used when the environment resistant I/O unit SL-TW is connected at the end of the main cable. IP67 4-pin SL-WP4: Suitable cable diameter "3 to "4mm SL-WP5: Suitable cable diameter "4 to "5mm SL-WP6: Suitable cable diameter "5 to "6mm IP67 4-pin IP67 4-pin SL-WY SL-WP8: Suitable cable diameter "6 to "8mm IP67 4-pin SL-WJ8: Suitable cable diameter "6 to "8mm Handy Monitor SL-HM1 * Easy input/output check * A handy monitor which can check I/O devices is available. The handy monitor can be hooked up to the S-LINK signal transmission lines at any place. I/O states can be checked in batches of 16. The handy monitor is also incorporated with the S-LINK controller functions, so that, for example, it can perform an I/O check on conveyor system segments, still under assembly, even without the S-LINK controller. Note: Although SL-HM1 incorporates the functions of the SL-CU1A controller, PLC I/O connectors cannot be connected. 38 IP67 4-pin SL-WE Controllers Suitable for S-LINK * Controllers for S-LINK released by other companies!! * Matsushita Electric Works, Mitsubishi Electric Corp., and Toyoda Machine Works have released controllers incorporating S-LINK controller functions so that the S-LINK system can be controlled without a separate S-LINK controller. Matsushita Electric Works Mitsubishi Electric Corp. Toyoda Machine Works * FP0-SL1 manufactured by Matsushita Electric Works Extremely small, large cost reduction The CPU unit of the PLC (programmable logic controller), I/O module, PLC I/O connector and the S-LINK controller functions are incorporated in an extremely small body of W30 H90 D60mm. The space required is greatly reduced and compactness can be achieved. Further, large cost reduction can also be realized. No. of control points: S-LINK 128 pointsNormal wiring 96 points On the S-LINK side 64 inputs and 64 outputs (fixed), a total of 128 points can be controlled and, by adding 3 Nos. of I/O modules, a max. of 96 points can be controlled by normal wiring. * Please contact Matsushita Electric Works, Mitsubishi Electric Corp., and Toyoda Machine Works for details. Manifold Electromagnetic Valves Suitable for S-LINK * `T'-branch connection manifold electromagnetic valves * Manifold electromagnetic valves capable of direct `T'branch connection to the S-LINK cable are available from Koganei Corp., SMC Pneumatics and CKD Corp. Koganei Corp. CKD Corp. SMC Pneumatics * Please contact Koganei Corp. (Humphry Products Company in U.S.A. and Canada), SMC Pneumatics or CKD Corp. for details. Limit Switches Suitable for S-LINK * Direct connection of limit switches to S-LINK system!! * Limit switches which can be directly connected to the S-LINK system transmission line by `T'-branch connection are available from Matsushita Electric Works. Matsushita Electric Works * Please contact Matsushita Electric Works for details. 39 WIRE-SAVING SYSTEMS S-LINK Family Products: Launched One After Another Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK WIRE-SAVING SYSTEMS SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop S-LINK APPLICATIONS This product does not possess control functions needed for accident prevention or safety maintenance. Handle safety related or emergency stop signals without passing them through the S-LINK system due to fail-safe considerations. Distributed Installation Conveyor S-LINK direct hook-up photoelectric sensor Booster PLC PLC I/O connectors 2 channel input unit S-LINK controller In a product transportation equipment, there are many input and output devices spread over various places. Although wire-saving has always been desired to reduce the cost and shorten the time of installation, long distance transmission and product reliability are essential. S-LINK allows a cable length of 200m, normally, and 400m along with a booster. The double code collation check plus high noise immunity enable signal transmission reliability. Furthermore, the S-LINK tree wiring architecture enables you to branch off sub-trunk lines or branch lines and hook-up input and output devices, anywhere you like. Test and installation block-by-block, and layout change after installation are quite simple jobs. Easy hook-up 24V DC power supply 1 channel I/O unit (output usage) S-LINK hook-up connector 2 channel I/O unit Parking garage Manifold electromagnetic valves suitable for S-LINK Booster AGV Use of flexible cable for moving equipment Personal computer Sensor Sensor Sensor Sensor The S-LINK system is very suitable to wire up car detection sensors in a large parking garage. It reduces wires and installation time. 40 Extremely effective in wire-saving with movable equipment. The signal transmission to AGV from a stationary controller has been very difficult. As the S-LINK system allows use of commercial cables in the system, the AGV equipped with the sensors and actuators can be linked with the stationary controller via one flexible cable. Besides, the S-LINK alarm capability, that generates an error output for a cable break, enables quick repair and ensures the system reliability. Integrated Installation Automatic assembly machine Snap-connector sensor blocks Sensor blocks with fiber sensors S-LINK hook-up connector 2 channel output unit Output arrayed terminal unit Manifold electromagnetic valves suitable for S-LINK 2 channel I/O unit Input arrayed terminal unit In an automatic assembly machine, there are many input and output devices distributed in various tight spaces. As the machine becomes more complex, the task of reducing the cable volume becomes more difficult. Wire-saving is the primary requirement, but reliability of signal transmission is also indispensable. In the S-LINK loop wiring, the system maintains signal transmission even when the loop may break at any one place. In the S-LINK standard wiring, the controller reveals disconnected device addresses when the signal transmission line may break. Further, even if excess current may flow by a short-circuit between the signal transmission lines, the controller shuts down the entire system. Plug-in connection 24V DC power supply PLC 1 channel I/O unit (input usage) PLC I/O connector S-LINK controller Handler Parts delivery system An IC handler uses many sensors. The S-LINK system contributes in reducing wires in order to miniaturize the machine. In a parts-taking verification system, the parts shelves are equipped with a number of area sensors at the front. The inputs equal the number of shelves and if job indicators are used, there are an equal number of outputs. The S-LINK system wires up all the area sensors with effective space and wire saving. 41 WIRE-SAVING SYSTEMS APPLICATIONS Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW S-LINK WIRE-SAVING SYSTEMS SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop S-LINK S-LINK SYSTEM CONFIGURATION EXAMPLE S-LINK control unit S-LINK is a wire-saving system which allows connection to max. 128 I/O devices by using one controller. Indicates an IN input device an OUT Indicates output device ( Limit switch, photoelectric sensor, inductive proximity sensor, push-button switch, cylinder switch, etc. ( Lamp, buzzer, relay, electromagnetic valve, solenoid, etc. Plug-in to PLC I/O modules Multi-core cable PLC input unit PLC input connector SL-S PLC output connector Multi-core cable PLC output unit SL-P ) The number of and shows the number of connections that can be made to that device. IN FP3, FP10S, FP10SH series Use multi-core cable PLC I/O connectors when terminal block type PLC is used for control. ) OUT SL-FAM3 0 VME bus S-LINK control board PCI bus S-LINK control board SL-VMES2 SL-PCI NEC PC/FC-98 series S-LINK control board SL-CU1A A D G 24 IN 0 Matsushita Electric Works PLC bus S-LINK controller Matsushita Electric Works PLC bus S-LINK control board SL-FP3 SL-FPC SL-SP S-LINK suitable controllers Multi-core cable PLC output unit (PNP) FP0-SL1, FP2-SL2, FP2-C1SL SL-A Booster SL-BS1A Further 200m Sharp PLC bus S-LINK control board Supplied by Matsushita Electric Works. SL-PP SL-N15 Transmission distance extended from 200m to 400m 2 SL-PC98 B D G S-LINK controller S-LINK direct hook-up photoelectric sensor 1 24 0 S-LINK direct hook-up area sensor SL-PCAT 24 Multi-core cable PLC input unit (PNP) Power supply PC/AT S-LINK control board Yokogawa Electric PLC bus S-LINK controller SL-S SL-P Note: Please refer to P. 30, 31 for products compatible with fieldbus networks Direct hook-up sensors Others Slot-in to MEW FP3/FP10S(H) series SL-Z300 24V DC 10% Local power supply S-LINK input devices 8 inputs are connectable. S-LINK output devices OUT OUT OUT OUT 2 channel output unit SL-CH1 SL-CH1-PN SL-CH22 SL-CH22-PN 2 channel I/O unit 1 2 3 4 5 6 7 OUT OUT OUT 1 output and 1 input, total 2 I/Os are connectable. 2 outputs are connectable Either 1 output or 1 input is connectable Environment resistant I/O unit SL-TW2P2, SL-TW2P2-PN 8 channel snapconnector output unit S-LINK direct hook-up manifold electromagnetic valves 16 outputs are connectable IN IN FX-J 4 inputs ( SL-BM Input arrayed terminal unit Environment resistant input unit SL-TB SL-TB-P SL-TW4, SL-TW4-PN SL-TW8, SL-TW8-PN 4 inputs, 8 inputs, 16 inputs Selectable from 4, 8 or 16 input models. GA-14J, GA-15J IN 4 inputs, 8 inputs Selectable from 4 or 8 input models. Maximum 3 plug-in unit extension blocks can follow 1 plug-in unit sensor main block. ) Snap-connector extension block Relay output terminal unit SL-TPR4 SL-TPR8 OUT OUT 4 outputs, 8 outputs, 16 outputs Selectable from 4, 8 or 16 output models. 4 outputs, 8 outputs Selectable from 4 or 8 output models. IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN IN Connectors SL-CP3 SL-CJ 4 IN IN IN IN IN IN IN IN IN IN 3 2 1 SL-JK S-LINK handy monitor performs I/O check by connecting to any point on the main/branch cable. Further, it is also equipped with S-LINK controller functions. G ) (BK D ) (WH 0V I/O modules mountable on your custom PCB. Handy monitor SL-HM1 ) (BU 24V I/O CK CHE 0V I/O modules ER4 S RES ADD L TRO CON 32 S RES ADD 7F) .(0l HEX 16 S RES ADD CT ELE P.S DIS ) 127 .(0l DEC TOP 8 64 NT COU 1 5 ON 2 S RES ENT ADD REM INC T UNI 4 6 4 7 11 16 8 S RES ADD TOP 0 32 1 ON 14 2 M 64 -H OR NIT MO 13 SL OR NIT MO DY HAN 12 PUT PUT OUT OUT 1 15 3 EN 5 OFF ON/ 4 A DAT 8 9 ON 6 N) 10 7 FF) E(O ABL DIS 11 12 13 OFF ON/ UT A DAT INP 14 I/O 15 T TES Custom PCB 24V ER3 4 10 Various S-LINK connectors for simple cable connections. L TRO CON L TRO CON ER1 ON 2 9 OR NIT MO 8 SL-CBM100/CBM200 ) (BN D SEN SL-J3A SET SL-JE-RC PUT OUT SL-TWP4, SL-TWP4-PN IN 3 42 SL-TBDA1 IN I/O modules SL-M8(F) (8 inputs) SL-M16(F) (16 inputs) SL-MP8(F) (8 outputs) SL-MP16(F) (16 outputs) SL-M4P4(F) (4 inputs and 4 outputs) SL-RCM100/RCM200 S-LINK exclusive cabtyre cable Environment resistant output unit IN Other S-LINK devices 4-core flat cable which can be easily `T'-branched. Analog output arrayed terminal unit IN 1 4 outputs S-LINK exclusive flat cable IN SL-T16C1 SL-T16C1-PN SL-CP `T'-branch multi-drop wiring system IN 2 OUT 8 channel snapconnector input unit 1 1 output IN 16 channel MIL connector input unit SL-JE OUT IN 0 SL-TP16C1 SL-TP16C1-PN Cables is the trademark of S-LINK. IN 16 inputs are connectable Maximum 16 inputs can be connected. SL-J1A 16 channel MIL connector output unit IN SL-T8J SL-T8J-PN SL-BMJ SL-TBP SL-TBP-PN SL-TBP-TY IN SL-BXJ OUT OUT OUT OUT Output arrayed terminal unit IN SL-TJ1 Supplied by Matsushita Electric Works. Snap-connector sensor main block OUT OUT OUT OUT IN S-LINK direct hookup limit switch 8 inputs are connectable. 2 inputs OUT OUT OUT OUT IN 8 inputs are connectable. Supplied by Koganei Corp., SMC Corp. and CKD Corp. OUT OUT OUT OUT SU-7J SL-BX Plug-in unit sensor main block IN Amplifier-separated Amplifier-separated Input terminal unit photoelectric sensor inductive proximity sensor Plug-in unit extension block OUT 2 outputs IN SL-TP8J SL-TP8J-PN IN Maximum 16 inputs can be plugged in. 2 inputs are connectable Analog input arrayed terminal unit SL-TBAD4 SL-CH21 SL-CH21-PN IN SL-CH21K OUT OR IN 0 Fiber sensor SL-CH20 SL-CH20-PN 1 channel I/O unit 8 outputs are connectable OUT OUT OUT OUT Plug-in units (4 units per block) 2 channel input unit WIRE-SAVING SYSTEMS SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop S-LINK ORDER GUIDE PLC related units Model No. Designation Appearance (Note1) For input SL-S1 Fujitsu connector specs. SL-S2 For output SL-P1 SL-P2 Description Manufacturer PLC PLC input PLC output module (Note 4) module (Note 4) Matsushita FP3, FP10S AFP33027 Electric Works FP10SH AFP33487 Toshiba Machine Co. TC64DON TC200 TC64DI NS series NS-X64-1 NS-Y64-T1 NS-XY64-1 (X side) NS-XY64-1 (Y side) F55 NV1X3204 NV1X3204-W NV1Y32T05P1 NV1X3206 F70 NC1X3204 NC1X3204-3 NC1Y32T05P1 NC1X3206 NC1Y64T05P1-1 NC1X6404 NC1W6406T(Y side) NC1X6406 NC1W6406T(X side) Fuji Electric Co. MIL connector specs. FTU125A FTU222A F80H, F120H FTU126A F120S FTU227C FTU127C F140S, F15XS FTU612A (Y side) FTU612A (X side) PLC input connectors PLC output connectors (same shape) PLC input connector PLC output connector (Note 2, 3) PLC I/O connectors Max. four PLC I/O connectors can be cascaded with one S-LINK controller. ( ) PLC Control cable Cascade cable End connector The listed PLC I/O modules (NPN only) allow the mating PLC I/O connector to be plugged on them for signal transmission between the PLC and the S-LINK controller. The PLC I/O connector converts I/O data from serial to parallel, and vice versa. I/O points: 32 points per connector SL-S3 SL-S4 SL-P3 SL-P4 Mitsubishi Electric Corp. Sharp Corp. AnS A1SX41 A1SY41 A1SX42 A1SY42 A1SH42 (X side) A1SH42 (Y side) AnN, AnA, AnU QnA, QnAs AX42 AY42 AH42 (X side) AH42 (Y side) A2CJ AJ35TC1-32D AJ35TC1-32T JW20, JW20H JW30H JW-234N JW-264N JW-232S JW-262S JW50H JW-34NC JW-64NC JW-32SC JW-62SC CVM1,CV,C500 C500-ID219 C500-OD213 C1000H,C2000H Omron Corp. SL-S5 SL-P5 C200H series Yokogawa Electric Corp. CQM1 CQM1-ID213 CQM1-OD213 FA500 XD64-6N YD64-1A WD64-6N (X side) WD64-6N (Y side) FA-M3 F3XD32-3N F3YD32-1A F3XD64-3N F3YD64-1A T3 Toshiba Corp. C200H-ID216 C200H-OD218 C200H-ID217 C200H-OD219 DI-335 DI-335H Yasukawa Electric GL20,GL40S,GL60S Corp. GL60H,GL70H SL-S6 SL-P6 SL-S7 End connector Cascade cable Control cable SL-E SL-F70 SL-F150 SL-F250 SL-F1000 SL-C1000 SL-C2000 SL-C5000 SL-C2000F Hitachi H series Yasukawa Electric GL20,GL40S,GL60S Corp. GL60H,GL70H DO-335 B2604 XDC24D2H YTR24DH B2605 It must be connected at the end of the last PLC I/O connector. Length: 70mm Length: 150mm Length: 250mm It links two PLC I/O connectors. Length: 1,000mm Length: 1m Length: 2m Length: 5m It links the S-LINK controller and the first PLC I/O connector. Length: 2m Notes: 1) Components with ` ' mark conform to the CE marking EMC Directive. However, note that for the PLC I/O connectors to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or SL-F250 and control cable SL-C2000F. Notes: 2) The PLC I/O connectors use Fujitsu connectors. However, SL-S1, SL-P1, SL-S6 and SL-P6 connectors use MIL connectors. Notes: 3) PLC I/O connectors are connectable to S-LINK controller SL-CU1A only. Notes: 4) X side and Y side indicate the input and the output connectors, respectively, of the compound input/output module. 44 ORDER GUIDE PLC related units Model No. Appearance (Note) PLC PNP type Multi-core cable PLC I/O unit NPN type For input SL-S SL-P SL-SP SL-PP Multi-core cable Multi-core cable PLC I/O unit Multi-core cable Description For output SL-L2000F The multi-core cable PLC I/O unit, connectable with any type of screw-on terminal type PLC I/O module via the multi-core cable, interfaces I/O data between the S-LINK controller and PLC. It includes the I/O data conversion circuit for serial to parallel or parallel to serial conversion. I/O points: 32 points per unit Connection to screw-on terminal type PLC is by an optional multi-core cable attached with an MIL connector on one end. Length: 2m The multi-core cable attached with an MIL connector on one end links the multi-core cable PLC I/O unit to a screw-on terminal type PLC I/O module. Note: Components with ` ' mark conform to the CE marking EMC Directive. However, note that for the multi-core cable PLC I/O units to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or SL-F250, control cable SL-C2000F and multi-core cable SL-L2000F. S-LINK control units Designation S-LINK controller VME bus S-LINK control board Appearance (Note) Model No. Description SL-CU1A It supplies the synchronization signal to the complete system to send and receive I/O data from external devices correctly. It also monitors the signal transmission line, and specifies the addresses of the disconnected devices if the line breaks, etc. SL-VMES2 It can be directly connected to the VME bus line to control the S-LINK system. It provides two S-LINK ports, each allowing 128 I/O points maximum, so that a total of 256 I/O points can be controlled. By using this control board, the SL-CU1A controller, the PLC I/O connectors, and their link cables are not required. ( ) PCI bus S-LINK control board SL-PCI It can be fitted into the expansion slot (PCI bus) of a personal computer to control the S-LINK system. By using this control board, the SL-CU1A controller, the PLC I/O connectors, and their link cables are not required. PC/AT S-LINK control board SL-PCAT It can be fitted into the expansion slot (ISA bus) of PC/AT series or compatible to control the S-LINK system. By using this control board, the SL-CU1A controller, the PLC I/O connectors, and their link cables are not required. NEC PC/FC-98 series S-LINK control board SL-PC98 It can be fitted into the expansion slot (C bus) of NEC PC/FC-98 series to control the S-LINK system. By using this control board, the SL-CU1A controller, the PLC I/O connectors, and their link cables are not required. SL-FP3 It can be directly connected to the bus line of the FP3, FP10S or FP10SH series PLCs manufactured by Matsushita Electric Works to control the S-LINK system. By using this controller, not only the SL-CU1A controller, the PLC I/O connectors, and their link cables, but also the PLC I/O modules are not required. SL-FAM3 It can be directly connected to the bus line of the FA-M3 PLC manufactured by Yokogawa Electric to control the S-LINK system. By using this master unit, not only the SL-CU1A controller, the PLC I/O connectors, and their link cables, but also the PLC I/O modules are not required. SL-FPC It can be directly connected to the bus line of the FP-C PLC manufactured by Matsushita Electric Works to control the S-LINK system. By using this control board, not only the SL-CU1A controller, the PLC I/O connectors, and their link cables, but also the PLC I/O modules are not required. SL-Z300 It can be directly connected to the bus line of the J-board Z-300 series PLC manufactured by Sharp to control the S-LINK system. By using this control board, not only the SL-CU1A controller, the PLC I/O connectors, and their link cables, but also the PLC I/O modules are not required. Matsushita Electric Works PLC bus S-LINK controller Yokogawa Electric PLC bus S-LINK master unit Matsushita Electric Works PLC bus S-LINK control board Sharp PLC bus S-LINK control board Note: Components with ` ( ( ( ( ( ( ( ) ) ) ) ) ) ) ' mark conform to the CE marking EMC Directive. 45 Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW Designation WIRE-SAVING SYSTEMS S-LINK WIRE-SAVING SYSTEMS S-LINK ORDER GUIDE Products for fieldbus network Appearance (Note) Model No. Description S-LINK gateway controller for DeviceNet SL-GU1-D S-LINK gateway controller for connection to open network DeviceNet, widely used in the United States. S-LINK gateway controller for PROFIBUS-DP SL-GU1-P S-LINK gateway controller for connection to open network PROFIBUS-DP, widely used in Europe. S-LINK gateway controller for INTERBUS SL-GU1-I S-LINK gateway controller for connection to open network INTERBUS, widely used in Europe. S-LINK gateway controller for CC-Link SL-GU1-C S-LINK gateway controller for connection to fieldbus network CC-Link, promoted by Mitsubishi Electric Corp. S-LINK gateway controller for JPCN-1/RS-485 SL-CU1-485 S-LINK gateway controller for connection to open network JPCN-1, widely used in Japan. It incorporates S-LINK system control functions and slave functions conforming to JPCN-1 or RS-485 so that it can connect an S-LINK system to a JPCN-1 or RS-485 communication system. JPCN-1/RS-485 master board for PC/AT SL-PCAT-485 It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the JPCN-1/RS-485 master board for PC/FC-98 series SL-PC98-485 It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the JPCN-1/RS-485 master board for PC/104 bus It can be installed in the personal computer or board computer of a PC/104 bus so that the personal computer or board computer can be used as a JPCN-1 master. SL-PC104-485 It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the S-LINK system and the JPCN-1 mode which enables control of JPCN-1 conforming devices. Note: Components with ` It can be installed in the extension slot (ISA bus) of a PC/AT or compatible so that the personal computer can be used as a JPCN-1 master. S-LINK system and the JPCN-1 mode which enables control of JPCN-1 conforming devices. It can be installed in the extension slot (C bus) of an NEC PC/FC-98 series so that the personal computer can be used as a JPCN-1 master. S-LINK system and the JPCN-1 mode which enables control of JPCN-1 conforming devices. ' mark conform to the CE marking EMC Directive. S-LINK I/O devices Designation Appearance (Note) Model No. Description SL-CH1 NPN type SL-CH1-PN PNP type SL-CH21 NPN type SL-CH21-PN PNP type SL-CH21K Photocoupler isolation (NPN) type SL-CH20 NPN type SL-CH20-PN PNP type SL-CH22 NPN type 1 channel I/O unit It can be used as either an input unit or an output unit by switch selection. Hence, a sensor, limit switch, etc., is connectable when it is used as an input, and a relay, lamp, etc., is connectable when it is used as an output. 1 input and 1 output device are connectable. 2 channel I/O unit (Excluding SL-CH21K) 2 channel input unit It is suitable for power supply remote control function of NEC FA personal computer FC-98/FC98-NX series. 2 input devices are connectable. 2 channel output unit 2 output devices are connectable. SL-CH22-PN PNP type Connector I/O unit SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop Designation 8 channel snapconnector input unit SL-T8J 8 channel snapconnector output unit SL-TP8J 16 channel MIL connector input unit SL-T16C1 16 channel MIL connector output unit SL-TP16C1 Note: Components with ` 46 NPN type SL-T8J-PN PNP type NPN type SL-TP8J-PN PNP type NPN type SL-T16C1-PN PNP type NPN type SL-TP16C1-PN PNP type ' mark conform to the CE marking EMC Directive. 8 input or 8 output devices are connectable with snap male connectors. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. Since connection can be made with an MIL connector, 16 input or 16 output devices can be connected to this slim I/O unit. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. ORDER GUIDE S-LINK I/O devices I/O arrayed terminal unit Input terminal Output terminal Appearance (Note) Model No. Description SL-TB4 4 NPN inputs SL-TB4-PN 4 PNP inputs SL-TB8 8 NPN inputs SL-TB8-PN 8 PNP inputs SL-TB16 16 NPN inputs SL-TB16-PN 16 PNP inputs SL-TBP4 4 NPN outputs SL-TBP4-PN 4 PNP outputs SL-TBP8 8 NPN outputs SL-TBP8-PN 8 PNP outputs SL-TBP16 16 NPN outputs They are screw-on terminal units to which 4, 8 or 16 input devices are connectable. Since power supply terminals have been provided for each input channel, neat wiring is possible. They are screw-on terminal units to which 4, 8 or 16 output devices are connectable. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. SL-TBP16-PN 16 PNP outputs Analog I/O arrayed terminal unit Separate load power supply type Input terminal Output terminal Environment resistant I/O unit Input unit SL-TBP4-TY 4 NPN oututs SL-TBP8-TY 8 NPN outputs SL-TBP16-TY 16 NPN outputs They enable forced turning OFF of the output device connected to the output terminal without halting the complete S-LINK system, by switching off the load power supply. 4 inputs This is an analog input terminal unit which can connect 4 devices having an analog output. SL-TBDA1 1 output This is an analog output terminal unit which can connect one device requiring an analog input. It is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. SL-TW4 4 NPN inputs SL-TW4-PN 4 PNP inputs SL-TW8 8 NPN inputs SL-TW8-PN 8 PNP inputs SL-TBAD4 These are units which can connect 4 or 8 input devices. They feature IP67 (IEC 60529) protection, which can withstand water splashes. The input devices can be easily connected by using optional composite connectors. 2 NPN inputs and These are units which can connect 2 inputs and 2 outputs. They feature IP67 (IEC 60529) protection, which can 2 NPN outputs withstand water splashes. They are incorporated with an output signal hold function, 2 PNP inputs and which retains the output state just prior to an error on the SL-TW2P2-PN 2 PNP outputs signal transmission line. SL-TW2P2 I/O unit SL-TWP4 4 NPN outputs Output unit SL-TWP4-PN 4 PNP outputs Note: Components with ` These can connect 4 output devices. They feature IP67 (IEC 60529) protection, which can withstand water splashes. They are incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line. ' mark conform to the CE marking EMC Directive. 47 Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW Designation WIRE-SAVING SYSTEMS S-LINK WIRE-SAVING SYSTEMS S-LINK ORDER GUIDE S-LINK I/O devices Model No. Description SL-TPR4 4 outputs (Note 2) 8 relay output SL-TPR8 8 outputs (Note 2) SL-BMJ It allows connection of various kinds of input devices, such as, photoelectric sensors, inductive proximity sensors, limit switches, and push buttons with the snap female connectors. One SL-BMJ can be extended by one SL-BXJ or two SL-BXs, up to 16 input points. It can generate the ORed self-diagnosis output of all the connected devices. In this case, the first channel gets occupied. Snap-connector Relay output terminal unit Appearance (Note1) 4 relay output Sensor main block Extension block For plug-in unit Sensor block They are terminal units to which 4 or 8 output devices can be connected by slim socket relays that can be easily replaced. They are incorporated with an output signal hold function which retains the output state just prior to an error on the signal transmission line. ( Sensor main block ) SL-BXJ It can follow either main block, and allows connection of 8 input devices. SL-BM It allows connection of various kinds of plug-in units of fiber sensors, amplifier-separated photoelectric sensors, amplifier-separated inductive proximity sensors and input terminal units. One SL-BM can be extended by three SL-BXs or one SL-BX plus one SL-BXJ, up to 16 input points. It can generate the ORed self-diagnosis output of all connected units. In this case the first channel gets occupied. ( Extension block Digital setting fiber sensor (Note 3) SL-BX Amplifierseparated inductive proximity sensor Its thickness is merely 10mm. The incident light intensity and the threshold value can be seen at a glance from the backlit LCD. Further, threshold value setting is simple by using the industry's first jog switch. (For details, refer to P.64l for the FX-D1 series.) FX-D1J Red LED FX-A1J Red LED FX-A1GJ Green LED FX-M1J Red LED FX-M1GJ Green LED SU-7J Its thickness is merely 10mm. The sensitivity is automatically set with ease. 12 kinds of sensor heads are suitable with it. (For details, refer to P.350l for the SU-7 series.) Manual setting fiber sensor Amplifierseparated photoelectric sensor ) It can follow either main block, and allows connection of four plug-in units. Auto-setting fiber sensor Plug-in unit SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop Designation Its thickness is merely 10mm. The sensitivity setting is simple by using the industry's first jog switch. Level indicators, comprising of 10 LEDs, which enable confirmation of the set sensitivity at a glance, have been incorporated. (For details, refer to P.64l for the FX-A1 series.) Its thickness is merely 10mm. Since the sensitivity setting is done by a 12-turn potentiometer, fine setting is possible. (For details, refer to P.64l for the FX-M1 series.) One-touch clamping type GA-14J Screw tightening type GA-15J Its thickness is merely 10mm. The sensitivity is so precisely set with the 18turn adjuster that the sensor is suitable for sophisticated applications with a high repeatability of 1!m or less. (For details, refer to P.686l for the GA-10 series.) SL-TJ1 It allows connection of 1 No. of various kinds of input devices, such as, a photoelectric sensor, an inductive proximity sensor or a limit switch. Input terminal unit Notes: 1) Components with ` ' mark conform to the CE marking EMC Directive. Notes: 2) Relay output is `Contact a' only. Further, when replacing the relay, use PA relay (APA 3312) made by Matsushita Electric Works. Notes: 3) Output 2 cannot be used when connection is made to the plug-in unit sensor block. 48 ORDER GUIDE S-LINK I/O devices Appearance Retroreflective type with polarizing filters S-LINK direct hookup photoelectric sensor Thru-beam type Diffuse reflective type Model No. Description SL-A11 Thru-beam type 10m SL-A13 Thru-beam type 30m SL-A19 These can be hooked up to the S-LINK cable, at Retroreflective type with any place, without any interface. polarizing filters 0.1 to 5m SL-A12 Diffuse reflective type 700mm Sensing range: 0.2 to 3m It is a parts-taking verification sensor with five sensing beams and can be hooked up to the S-LINK cable without any interface. * Beam pitch: 25mm * Sensing height: 100mm Both the emitter and the receiver are incorporated with bright orange LED job indicators * Sensing object: "35mm or more that are easily visible to the operator. opaque object to 1m when the ( 0.05 switch is set to SHORT ) S-LINK direct hookup area sensor Vertical type Input module I/O mixed module Horizontal type I/O module Output module Input module I/O mixed module Output module SL-N15 SL-M8 8 inputs SL-M16 16 inputs SL-M4P4 4 inputs and 4 outputs SL-MP8 8 outputs SL-MP16 16 outputs SL-M8F 8 inputs SL-M16F 16 inputs SL-M4P4F 4 inputs and 4 outputs SL-MP8F 8 outputs SL-MP16F 16 outputs These are IC type modules which enable external connection of address setting switches and operation indicators. They increase the design flexibility. 49 Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW Designation WIRE-SAVING SYSTEMS S-LINK WIRE-SAVING SYSTEMS S-LINK ORDER GUIDE Connectors SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop Designation Appearance Model No. Description Hook-up connector SL-J1A It creates a `T'-branch connection between two S-LINK exclusive flat cables. (Gray) For 0.5mm2 flat cable to 0.5mm2 flat cable connection (1 set: 10 Nos.) Cable extension hook-up connector SL-J3A It can extend the S-LINK exclusive flat cable. (Black) For 0.5mm2 flat cable to 0.5mm2 flat cable connection (1 set: 10 Nos.) End hook-up connector SL-JE It must be connected at the end of the main cable. (Gray) For 0.5mm2 flat cable (1 set: 5 Nos.) Cable attached end connector SL-JE-RC (Gray) (1 set: 1 No.) Cable end socketbranch hook-up connector It enables one I/O device to be connected at the S-LINK exclusive flat cable SL-JK end with the snap male connector SL-CP1, SL-CP2 or SL-CP3. (Light blue) (1 set: 10 Nos.) For 0.5mm2 flat cable When cabtyre cable is used as the main cable, the end connector can be easily connected. SL-JK1 It enables one I/O device to be branched off in the middle of the S-LINK exclusive flat cable with the snap male connector SL-CP1, SL-CP2 or SL-CP3. (1 set: 10 Nos.) For 0.5mm2 flat cable Socket-branch hookup connector (Blue) SL-CJ1 (White) For 0.08 to 0.2mm2 4-pin type snap female connector Wire dia.: "0.7 to "1.2mm It can be plugged into the socket of SL-BMJ or SL-BXJ to connect an input device, or into the snap male connector SL-CJ2 (Black) For 0.3mm2 SL-CP1, SL-CP2 or SL-CP3 to extend the cable length. (1 set: 10 Nos.) Wire dia.: "1.1 to "1.6mm (1 set: 10 Nos.) 1 2 3 4 SL-CJ12 (White) For 0.08 to 0.2mm2 (1 set: 10 Nos.) 2-pin type snap female connector Wire dia: "0.7 to "1.2mm SL-CJ22 (Black) For 0.3mm2 (1 set: 10 Nos.) It can be used for cable extension of 2-wire I/O devices by combining with a snap male connector SL-CP12 or SL-CP22. Wire dia: "1.1 to "1.6mm SL-CP1 (White) For 0.08 to 0.2 mm2 (1 set: 10 Nos.) 1 4-pin type snap male connector 2 3 4 Wire dia.: "0.7 to "1.2mm It can be plugged into the socket of SL-T8J or SL-TP8J to connect an I/O device, or into the socket-branch hook-up Wire dia.: "1.1 to "1.6mm connector SL-JK or SL-JK1 to connect an S-LINK direct hook-up sensor. Using SL-CP3, S-LINK I/O devices (with 0.5mm2 cable) can be easily connected/ disconnected from the For 0.5mm2 Wire dia.: "1.7 to "2.5mm main/branch cable. SL-CP2 (Black) For 0.3mm2 (1 set: 10 Nos.) SL-CP3 (Greenish blue) (1 set : 10 Nos.) SL-CP12 (White) For 0.08 to 0.2mm2 2-pin type snap male connector Wire dia.: "0.7 to "1.2mm It can used for cable extension of 2-wire I/O devices by combining with a snap female connector SL-CJ12 or SL-CP22 (Black) For 0.3mm2 SL-CJ22. (1 set: 10 Nos.) Wire dia.: "1.1 to "1.6mm (1 set: 10 Nos.) NOTE The connectors are supplied in sets of 10 Nos. (SL-JE: 5 Nos., SL-JE-RC: 1 No.) Please order in units of 10 Nos. (SL-JE: 5 Nos., SL-JE-RC: 1 No.) (e.g.) In case 30 Nos. of SL-J1A are required, order SL-J1A3 (sets). 50 ORDER GUIDE Connectors Appearance Model No. Description SL-WP4 For 0.18 to 0.75mm2 (1 set: 10 Nos.) Wire dia.: "3 to "4mm For 0.18 to 0.75mm2 SL-WP5 (1 set: 10 Nos.) Wire dia.: "4 to "5mm These are composite male connectors for connection of For 0.18 to 0.75mm2 SL-WP6 input or output devices to the environment resistant I/O unit (1 set: 10 Nos.) Wire dia.: "5 to "6mm SL-TW, and for connection to the branch connector Composite male connector Water resistant connector SL-WY or the composite female connector SL-WJ8. For 0.3 to 0.75mm2 SL-WP8 (1 set: 10 Nos.) Wire dia.: "6 to "8mm These are composite female connectors for connection to the main cable side of the environment resistant I/O unit For 0.3 to 0.75mm2 SL-WJ8 (1 set: 10 Nos.) Wire dia.: "6 to "8mm SL-TW, and for connection to the branch connector Composite female connector SL-WY or the composite male connector SL-WP. This is a connector for branching of the main/branch cable and for connection Branch connector SL-WY of the thru-beam type photoelectric sensor to the environment resistant I/O (1 set: 5 Nos.) unit SL-TW. Environment resistant end connector SL-WE (1 set: 1 No.) It is connected when the environment resistant I/O unit SL-TW is used at the end of the main cable. NOTE The connectors are supplied in sets of 10 Nos. (SL-WY: 5 Nos., SL-WE: 1 No.) Please order in units of 10 Nos. (SL-WY: 5 Nos., SL-WE: 1 No.) (e.g.) In case 30 Nos. of SL-WP4 are required, order SL-WP43 (sets) Optional units Designation Booster Handy monitor Note: Components with ` Appearance (Note) Model No. Description SL-BS1A It can extend the signal transmission distance by 200m. A maximum of seven boosters can be connected for one S-LINK control unit. However, one booster can never be followed by another booster in series. SL-HM1 It can be connected at any place on the signal transmission line and the I/O states can be checked in batches of 16. The handy monitor is also incorporated with the S-LINK control functions, so that, for example, it can perform an I/O check on conveyor system segments, still under assembly, even without the S-LINK controller. ' mark conform to the CE marking EMC Directive. 51 Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW Designation WIRE-SAVING SYSTEMS S-LINK WIRE-SAVING SYSTEMS S-LINK ORDER GUIDE Others SL-BMW/BW S-LINK Simple Wiring `T'-branch Multi-drop Designation Appearance Model No. Description SL-RCM100 D line: White SL-RCM100-PK D line: White with pink stripe Length: 100m S-LINK exclusive flat cable SL-RCM100-GN SL-RCM100-GY S-LINK exclusive flat cable (4-core) D line: White 2 with green stripe * Conductor cross-section area: 0.5mm * Outer diameter: "2.5mm4 D line: White with gray stripe SL-RCM200 Length: 200m SL-CBM100 Length: 100m SL-CBM200 Length: 200m S-LINK exclusive pliers SL-JPS Hook-up connector (SL-J) can be connected in one grip. S-LINK exclusive ratchet pliers SL-JPD Because of the ratchet mechanism, hook-up connector (SL-J) can be simply connected in one grip. SL-CP3 exclusive pliers SL-JPE Snap male connector (SL-CP3) can be connected in one grip. SL-CJ1/2/12/22 and SL-CP1/2/12/22 exclusive pliers SL-JPC Hook-up connector (SL-CJ1/2/12/22, SL-CP1/2/12/22) can be connected in one grip. Cover for M12 male connector SL-WPK Make sure to put it on the unused main cable side connectors of the (1 set: 10 Nos.) environment resistant I/O unit SL-TW. Cover for M12 female connector Make sure to put it on the unused I/O side connectors of the environment SL-WJK (1 set: 10 Nos.) resistant I/O unit SL-TW. Marking plate It is used to write the I/O device No., address No., etc., on the environment SL-MA2 (1 set: 20 Nos.) resistant I/O unit SL-TW. I/O unit holder for SL-CH MS-SLH It is used to mount the SL-CH unit. (1 set: 5 Nos.) Address label By sticking the labels on the respective S-LINK devices, the set addresses can be confirmed at one glance. SL-MA1-SET SL-MA1-SET is available in white, pink, green and gray colors, as a 4-sheet (1 set: 4 sheets) set, and is convenient when used by matching the color with that of the S-LINK exclusive flat cable (100m type). S-LINK exclusive cabtyre cable S-LINK exclusive cabtyre cable (4-core) * Conductor cross-section area: 0.5mm2 * Outer diameter: "7.4mm NOTE The connectors are supplied in sets of 10 Nos., the marking plate in sets of 20 Nos., the I/O unit holder for SL-CH in sets of 5 Nos. and the address seal in sets of 4 sheets. Please order in units of 10 Nos., 20 Nos., 5 Nos. or 4 sheets, respectively. (e.g.) In case 10 Nos. of MS-SLH are required, order MS-SLH2 (sets). In case 8 sheets of SL-MA1-SET are required, order SL-MA1-SET2 (sets). 52 OPTION Sensor mounting bracket for SL-A Model No. Description MS-NX5-1 Foot angled mounting bracket (The thru-beam type sensor needs two brackets.) Sensor mounting bracket for SL-A MS-NX5-2 Foot biangled mounting bracket (sensor protection bracket) (The thru-beam type sensor needs two brackets.) MS-NX5-3 Back angled mounting bracket (The thru-beam type sensor needs two brackets.) MS-NA1-1 Sensor mounting bracket for SL-N15 MS-NA2-1 Four bracket set Four M4 (length 15mm) screws with washers, eight nuts, four hooks, four spacers and eight M4 (length 18mm) screws with washers are attached. (Spacers are not attached with MS-NA1-1.) Sensor protection bracket for MS-NA3 SL-N15 It protects the sensor body. Two bracket set Four M4 (length 15mm) screws with washers, and four nuts are attached. Reflector mountMS-RF23 ing bracket For RF-230 Slit mask for SL-N15 The seal type slit mask restrains the OS-NA1-5 (1 set: 10 sheets) amount of beam emitted or received. Connector I/O unit MS-DIN-3 mounting bracket * MS-NX5-1 * MS-NX5-2 Two M4 (length 25mm) screws with washers and two M4 nuts are attached. * MS-NX5-3 Two M4 (length 25mm) screws with washers and two M4 nuts are attached. Simple Wiring `T'-branch Multi-drop S-LINK SL-BMW/BW Designation Two M4 (length 25mm) screws with washers and two M4 nuts are attached. Sensor mounting bracket for SL-N15 * MS-NA1-1 * MS-NA2-1 2 MS-NA MS- NA 1 M4 screws with washers, nuts and hooks are attached. M4 screws with washers, nuts, hooks and spacers are attached. Sensor protection bracket Reflector mounting bracket for SL-N15 It is a DIN rail mounting bracket which can be fitted on the mounting base of SL-T8J(-PN), SL-TP8J(-PN), SL-T16C1(-PN) and SL-TP16C1(-PN). NOTE The slit mask for SL-N15 is supplied in sets of 10 sheets. Please order in units of 10 sheets. (e.g.) In case 20 sheets of OS-NA1-5 are required, order OS-NA1-52 (sets). M4 screws with washers and, nuts are attached. Slit mask for SL-N15 WIRE-SAVING SYSTEMS S-LINK Two M4 (length 10mm) screws with washers are attached. Connector I/O unit mounting bracket Since the slit mask is seal type, it can be used by sticking it to the detection surface. Take care that the sensing range will be reduced when the slit mask is used. Please contact our office for details. Please refer to the S-LINK Design Manual for the specifications and dimensions of the S-LINK devices. 53