- 436 -
1W005M THRU 1W10M
Single Phase 1.0 AMP. Silicon Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
1.0 Ampere
Features
a
UL Recognized File # E-96005
a
Surge overload ratings to 30 amperes
peak
a
Ideal for printed circuit board
a
Reliable low cost construction technique
results in inexpensive product
a
High temperature soldering guaranteed:
250 / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs. ( 2.3 Kg ) tension
Mechanical Data
a Case: Molded plastic
a Lead: Solder plated
a Polarity: As marked
a
Weight: 1.10 grams
WOB
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number 1W005M 1W01M 1W02M 1W04M 1W06M 1W08M 1W10M Units
Maximum Recurrent Peak Reverse Voltage 50 100 200 400 600 800 1000 V
Maximum RMS Voltage 35 70 140 280 420 560 700 V
Maximum DC Blocking Voltage 50 100 200 400 600 800 1000 V
Maximum Average Forward Rectified Current
@TA = 50 1.0 A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method ) 30 A
Maximum Instantaneous Forward Voltage
@ 1.0A 1.0 V
Maximum DC Reverse Current @ TA=25
at Rated DC Blocking Voltage @ TA=100 10
500 uA
uA
Typical Thermal resistance (Note) R
θ
JA
R
θ
JL 36
13
/W
Operating Temperature Range TJ -55 to +125
Storage Temperature Range TSTG -55 to +150
Note: Thermal Resistance from Junction to Ambient and from Junction to Lead Mounted on
P.C.B. with 0.47 x 0.47” (12 x 12mm) Copper Pads.
- 437 -
RATINGS AND CHARACTERISTIC CURVES (1W005M THRU 1W10M)
FIG.1- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
PEAK FORWARD SURGE CURRENT. (A)
12 10 20 10040 60
0
10
40
30
20
50
NUMBER OF CYCLES AT 60Hz
FIG.2- MAXIMUM FORWARD CURRENT DERATING
CURVE
AVERAGE FORWARD CURRENT. (A)
20 40 60 80 100 120 140
0
.2
.4
.6
.8
1.0
1.2
1.4
1.6
AMBIENT TEMPERATURE. ( C)
o
FIG.3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER BRIDGE ELEMENT
INSTANTANEOUS FORWARD CURRENT. (A)
02 4 6 8 10 12 14
0.01
0.1
1.0
20
10
FORWARD VOLTAGE. (V)
Tj=25 C
Pulse Width=300 s
1% Duty Cycle
o
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
INSTANTANEOUS REVERSE CURRENT.( A)
020 40 60 80 100 120 140
.01
.10
1.0
10
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
Tj=100 C
0
Tj=25 C
0