1997 Nov 13 27
Philips Components Product specification
Solid Al - electrolytic capacitors
Solid Al, Axial SAL-A 123
ADDITIONAL TESTS AND REQUIREMENTS FOR EPOXY-FILLED VERSIONS SAL-AG
2222 123 6.... Form BA ±20%
2222 123 8.... Form BA ±10%, level S
Table 9 Test procedures and requirements
TEST PROCEDURE REQUIREMENTS
Severe vibration tests in accordance with
“IEC 68-2-6”
and
“MIL STD-202”
, method 204, letter E, with the
following details and additions
Method of mounting: clamping both body and leads ∆C/C: ±10%
tan δ≤1.2 ×stated limit
Z≤1.4 ×stated limit
DC leakage current: ≤stated limit
no intermittent contacts
no indication of breakdown
no open circuiting
no evidence of mechanical
damage
severity 1 frequency range temperature
10 to 3000 Hz; 20-25 °C
severity 2 frequency range temperature
50 to 2000 Hz; 125 °C
severity 1 and 2 vibration amplitude: 50 g or 3.5 mm,
whichever is less
Direction and duration of motion:
severity 1 1 octave/minute; 3 directions (mutually
perpendicular); 20 sweeps per direction (total
60 sweeps or 18 hours)
severity 2 1 octave/minute; 2 directions (longitudinal
and transversal);
3 sweeps per direction (total 6 sweeps or
1 hour)
Functioning:
severity 1 rated voltage applied
severity 2 no voltage applied
Typical capability >80 g at 10 to 3000 Hz (also at 125 °C)
Severe shock tests in accordance with
“IEC 68-2-27”
and
“MIL STD-202”
, method 213, letter F, with the
following details and additions:
Method of mounting clamping both body and leads ∆C/C: ±10%
tan δ≤1.2 ×stated limit
Z≤1.4 ×stated limit
DC leakage current: ≤stated limit
no intermittent contacts
no indication of breakdown
no open circuiting
no evidence of mechanical
damage
Pulse shape half-sine or sawtooth
severity 1 1500 g; 0.5 ms (
“MIL STD-202”
, method 213,
letter F)
severity 2 3000 g; 0.2 ms
severity 3 10000 g; 0.1 ms
Direction and number of shocks:
severity 1 and 2 3 successive shocks in each direction of
3 mutually perpendicular axes
(total 18 shocks)
severity 3 1 shock in any direction
Functioning rated voltage applied