8[mXeZ\[@e[ljki`Xc8lkfdXk`fe
=`ijk-ddi\cXpn`k_jkife^d\Z_Xe`ZXcg`ej
0NSPOT(37
t -BSHFQMVHJOQJOT o &YDFMMFOU$POOFDUJPO
t -&%.FDIBOJDBM'MBH o $IFDL0QFSBUJPO
t 5SBOTQBSBOU)PVTJOH o $IFDL$POEJUJPO
t 4MJN0VUMJOF o 4QBDF4BWJOH
t 1VTIJO"DDFTTPSJFT o &BTZ8JSJOH
XXXPNSPOJOEVTUSJBMDPN
XXXPNSPOJOEVTUSJBMDPNTMJNSFMBZ
Efe$Y\e[XYc\
Details on the G2RV
Terminal Block-type Module
With a width of only 6.1 mm, the
G2RV meets essentially any FA
application, particularly switching
and expansion of equipment and
machinery. The G2RV is easily
installed even under strict space
limitations.
Stoppers and Levers
Easy-to-use stoppers and levers
securely hold the Relays to the
Base. They also enable easily
removing the Relays from the
sockets. The stoppers and levers
are also equipped with grooves
to attach markers, which can be
used to easily identify circuits.
Crossbars
P2RV Crossbars come in
many variations for the number
of poles and edge colors.
They can be plugged into any
of a total of four slots for
I/O according to the
application.
Wiring
The G2RV also provides flexibility for
wiring. The Bases in this new Relay
Series are available with screw
terminals or push-in terminals
for wire connection.
Choose the best connection method
for the application.
Slim Re lay G2RV 3
Slim Relay
G2RV
The World's First Industrial Slim Relay
Large plug -in te rminals for easy connection.
LED indicator and mechanical flag to check operation.
Transparent housing enables checking relay condition.
Slim outline to s ave spac e.
Push-in terminals and accessories for easy wiring.
Model Number Structure
Model Number Legend
1. Auxiliary Type Designation
SL: Slim relay and socket combination
2. Wire Connection
7: Screw terminals
5: Push-in terminals
3. Relay LED
0: Without LED
4. Relay Pushbutton
0: Without pushbutton
5. Input Voltage
Note: LED indicator availab le on Socket.
Ordering Information
List of Models
Relay and Socket Combinations
1234 5
G2RV-SL @ @ @ - @
Classification Enclosure rating Input voltage Type of connection Contact form
SPDT
Plug-in terminals General-purpose Unsealed AC/DC Screw terminals G2RV-SL700
Push-in terminals G2RV-SL500
Inpu t volta ge Sc r ew te r m inals Pu s h-in te rminals
12 VDC G2RV-SL700-12 VDC G2RV-SL500-12 VDC
24 VDC G2RV-SL700-24 VDC G2RV-SL500-24 VDC
24 VAC/DC G2RV-SL700-24 VAC/DC G2RV-SL500-24 VAC/DC
48 VAC/DC G2RV-SL700-48 VAC/DC G2RV-SL500-48 VAC/DC
110 VAC G2RV-SL700-110 VAC G2RV-S L500-110 VAC
230 VAC G2RV-SL700-230 VAC G2RV-S L500-230 VAC
4Slim Relay G2RV
Specifications
Input Ratings
Contact Ratings
Note: P level: λ60 = 0.1 x 10-6/operation
Characteristics
Note: Values in the above table are the initial values.
Approved Standard
UL 508 (File No. E41643)
IEC/VDE (EN 61810)
Rated voltage Rated current Operate voltage Release voltage Power consumption Input voltage
AC DC % of rated voltage AC (VA)
Approx. DC (mW)
Approx. % of rated voltage
50 Hz 60 Hz
12 VDC --- --- 27.2 80% 10% --- 300 mW ±10%
24 VDC --- --- 13.3 --- 300 mW
24 VAC/DC 21.1 22.5 13.0 0.5 VA 300 mW
48 VAC/DC 8.5 9.0 5.2 0.4 VA 250 mW
110 VAC 7.1 7.5 --- 0.8 VA ---
230 VAC 7.3 7.9 --- 1.7 VA ---
Number of poles 1 pole
Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms)
Rated load 6 A at 250 VAC;
6 A at 30 VDC 2.5 A at 250 VAC;
2 A at 30 VDC
Rated carry current 6 A
Ma x. switc h ing volt age 440 VA C, 125 VDC
Max. switchi ng curre nt 6 A
Max. switching power 1,500 VA
180 W 500 VA
60 W
Failure rate (reference value) 10 mA at 5 VDC
Item 1 pole
Contact material AgSnIn
Contact resistance 100 m max .
Operate time 20 ms max., DC input: 5 ms, AC/DC input: 5 ms, AC input: 12 ms (typical values)
Release time 40 ms max., DC input: 8 ms, AC/DC input: 25 ms, AC input: 32 ms (typical values)
Max. oper at ing fre qu en cy Mecha ni cal: 18,000 operations/h r
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 M min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts;
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)
Shock resistance Destructi o n: 1,00 0 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Endurance Mechanical: 5,000,000 operations min.
Electrical: 70,000 operations min. with NO contact, 50,000 operations min. with NC contact
Ambient temperature Operating: –40°C to 55°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 35 g
Overvoltag e cat eg or y III
Pollution degree 2
Conta ct form Coil rating s Conta ct ratings Operations
SPDT 12 to 48 VDC
24 to 230 VAC 250 VAC 6 A (Res.)
30 VD C 6 A (Res.)
400 VAC 2 A (Res.)
6,000
Conta ct form Coil rating s Conta ct ratings Operations
1 pole changeover 12, 24 VDC
24, 48 VAC /DC
110, 230 VAC
250 VAC 6 A (Res.)
30 VD C 6 A (Res.)
400 VAC 2 A (Res.)
50,000
50,000
6,000
Slim R elay G2RV 5
Accessories
PLC Interfaces
List of Models
Specifications
DeviceNet
List of Models
Specifications
Models with 16-input/16-output Connector
Models with 16-input Connector Models with 16-input/16-o utput Con ne ctor
Models with 16-outp ut Con ne ctor
Note: Do not allow the total external load current to exceed 2 A.
Do not allow the current for the V terminal or G ter minal to
exceed 1 A.
Model number Description Connection
P2R V-8-O-F For output use Flat cable
Input Rated voltage 30 VAC/VDC max.
Current capacity 0.5 A per channel
2.0 A total current, power supply terminal
Characteristics Ambient temperature Operating: 0 to 55°C
Storage: 20 to 85°C
Overvoltage category III
Pollu tio n de gr ee 2
I/O
type Internal
I/O
common
Number
of I/O
points
I/O
connec-
tions
Internal circuit
power Rated I/O
power
supply
voltage
Model
Inputs NPN (+ common) 16 MIL
connector Suppl ied from
communications
connector.
24 VDC DRT2-ID16ML
PNP ( common) DRT2-ID16ML-1
Out-
puts NPN ( commo n) DRT2-OD16 ML
PNP (+ common) DRT2-OD16ML-1
Item DRT2-ID16ML
DRT2-ID16MLX DRT2-ID16ML-1
DRT2-ID16MLX-1
Internal I/O
common NPN PNP
I/O points 16 inputs
ON voltage 17 VDC min. (between
each input terminal and V
terminal)
17 VDC min. (between each
input terminal and G terminal)
OFF voltage 5 VDC max. (between
each input terminal and V
terminal)
5 VDC max. (between each
input terminal and G terminal)
OFF cu rrent 1.0 mA max.
Input cur rent 6.0 mA max./po int (at 24 VD C )
3.0 mA max./po int (at 17 VD C )
ON delay time 1.5 ms max.
OFF delay time 1.5 ms max.
Maximum
number of
simultaneously
ON inputs
16
Circuits per
common 16/common
Item DRT2-OD16ML
DRT2-OD16MLX DRT2-OD16ML-1
DRT2-OD16MLX-1
Internal I/O
common NPN PNP
I/O points 16 out puts
Rate d output
current 0.3 A/point, 2 A/ common (See note 1.)
Residual
voltage 1.2 V max. (0.3 A DC be-
tween each output terminal
and G terminal)
1.2 V max. (0.3 A DC be-
tween each output terminal
and V terminal)
Leakage current 0.1 mA max.
ON delay time 0.5 ms max.
OFF de lay time 1.5 ms max.
Circuits per
common 16/common
6Slim Relay G2RV
Single Relays for Maintenance
Model Number Legend
1. Num ber of Poles
1: 1 pole
2. Terminals
S: Plug-In
3. Relay LED
Blank: Without LED
4. Relay Pushbutton
Blank: Without pushbutton
5. Contact Material
Blank: AgSnIn
6. Rated Coil Voltage
11 VDC, 21 VDC, and 48 VDC
List of Models
Crossbars
Model Number Legend
1. Num ber of Poles
020: 2 poles
030: 3 poles
040: 4 poles
100: 10 poles
200: 20 poles
2. Color
R: Red
S: Blue
B: Black
12345
6
G2RV-@ - @ @ @ - @- @
Model number Replacement for
G2RV-1-S DC11 G 2RV-SL7@@/5@@ DC12
G2RV-1-S DC21 G 2RV-SL7@@/5@@ DC24
G2RV-SL7@@/5@@ AC/DC24
G2RV-1-S DC48 G 2RV-SL7@@/5@@ AC/DC48
G2RV-SL7@@/5@@ AC110
G2RV-SL7@@/5@@ AC230
Model number Poles Color
P2RVM-020@2 Red (R)
Blue (S)
Black (B)
P2RVM-030@3
P2RVM-040@4
P2RVM-100@10
P2RVM-200@20
12
P2RVM -@ @
Slim R elay G2RV 7
Plasti c Labels fo r G2RV Sockets
Labels (Stickers) for G2RV Sockets
Separating Plate s
Connections
PLC Interfaces
Model number Quantity Color
R99-15 for G2RV 5 sheets × 120 labels =
600 labels (minimum order) White
Model number Quantity Color
R99-16 for G2RV 10 sheets × 484 labels =
4,840 labels (minimum order) White
Model number Quantity Description
P2RV-S 50 plates
(minimum order) Pro v ides isolation between
adjacent relays to achieve
440-V isolation.
1111
1414
1.....................8
1
23
45
67
89
10
P2RVC-8-O-F
8Slim Relay G2RV
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Complete Unit
G2RV-SL700
12
11
14
A1
A2
24 V DC
Terminal Arrangement/
Internal Connections
(Top View)
12
11
14
A1
A2
12 V DC
Terminal Arrangement/
Internal Connections
(Top View)
12
11
14
A1
A2
Other Coil Voltage
Terminal Arrangement/
Internal Connections
(Top View)
Five,
M2.5 × 6
6.2 max.
99.2 7.188.9
26.1
47.2
70.9
83
106.7 max.
92.7 max.
35
Input circuit
Slim R elay G2RV 9
G2RV-SL500
Single Relay
G2RV-1-S
12
11
14
A1
A2
24 V DC
Terminal Arrangement/
Internal Connections
(Top View)
12
11
14
A1
A2
12 V DC
Terminal Arrangement/
Internal Connections
12
11
14
A1
A2
Other Coil Voltage
Terminal Arrangement/
Internal Connections
(Top View)
6.2 max.
99.2
88.9 7.1
24.6
46
69.8
82.9
106.7 max.
97.4 max.
35
Input circuit
A2
A1
12
11
14
Terminal Arrangement/
Internal Connections
(Bottom View)
30.5 max.
3.5
0.5 2.4
1.8
5.2 max.
5.04 5.04
3
22
33 max.
16.2
Input circuit
10 Slim Relay G2RV
Installation
Tools
A flat-blade screwdriver should be used to mount the cables for G2RV-SL-500-series Relays when using standard wire without ferrules.
Applicable Screwdriver
Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
Examples: FACOM AEF.2.5×75E (AEF. 3×75E)
VESSEL No. 9900-(-)2.5×75 (No. 9900-(-)3×100)
WIHA 260/2.5×40 (260/3×50)
WEIDMULLER SD 0.4×2.5×7.5 (SD 0.5×3.0×80)
*Chamfering the tip of the driv er improves insertion when used as an exclusive tool.
Applicable Wires
Applicable Wire Sizes
G2RV-SL700 Series
G2RV-SL500 Series
Use wires of the applicable sizes specified in the above t ab le . The length of the exposed conductor should be 7 mm for a G2R V -SL700 series Rela y ,
12 mm for a G2RV-SL500 series Relay.
Flat-blade, Parallel-tip
Flat-blade, Flared-tip
2.5 dia. (3.0 mm max.)
Cannot be used.
Property Requirements
Cross-section with
clamping yoke technology 0.5 to 2.5 mm2: stranded/solid (without ferrules)
0.5 to 2.5 mm2: stranded wires with ferrules with plastic collar
0.5 to 2.5 mm2: stranded wires with ferrules without plastic collar
4 mm2: Solid
Stripping length: 7 mm
Property Requirements
Cross-section with
push-in technology 0.5 to 2.5 mm2: stranded/solid (without ferrules)
0.5 to 1.5 mm2: stranded wires with ferrules with plastic collar
0.5 to 2.5 mm2: stranded wires with ferrules without plastic collar
4 mm2: Solid
Stripping length: 12 mm
7 mm
Fi
g
. 1 Ex
p
osed Conductor Len
g
th
12 mm
G2RV-SL700
G2RV-SL500
Slim R elay G2RV 11
Wiring Procedure for G2RV-SL500 Series
Wiring (for S trande d Wires wi t h Ferr ules or So lid Wire)
Insert the exposed conductor into the connection hole.
No other tools are required.
Use the above procedure f or stranded wires without f errules, but add
the fol lowing step to the beginning of the procedure.
Remove
Insert the specified screwdriver into the release hole.
Remove wire.
Remove screwdriver.
Note: Remove the screwdriver all the way.
Release hole
Wire connection hole
Cable
In the interest of produc t improvement, speci fica tions ar e sub jec t to c hange witho ut notic e.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J163-E1-01
0606
OMRON RELAY & DEVICES Corporation
Power Relay Division
Marketing Department
1110, Sugi, Yamaga-c ity, Kumamoto-Pref., 861-0596 Japan
Tel: (81)968-44-4149/Fax: (81)968-44-4107
Precautions
Precautions for Connection
Do not move the screwdriv er up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e .g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
Do not insert the screwdriver at an angle. Doing so may break the
side of socket and result in a short-circuit.
Do not insert tw o or more wires in the hole. Wires may come in
contact with the spring causing a temperature rise or be subject to
sparks.
Insert the screwdriver along the hole wall as shown below.
If lubricating liquid, such as oil, is present on the tip of screwdriver,
the screwdriver may fall out resulting in injury to the operator.
Insert the screwdriver into the bottom of the hole. It may not be
possible to connect cables properly if the screwdriver is inser ted
incorrectly.
General Precautions
Do not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
Confirm that the socket is securely attached to the mounting track
before wiring. If the socket is mounted insecurely it may fall and
injure the operator.
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
Do not pour water or cleansing agents on the product. Doing so
may result in electric shock.
Do not use the socket in locations subject to solvents or alkaline
chemicals.
Do not use the socket in locations subject to ultraviolet light (e.g.,
direct sunlight). Doing so ma y result in markings fading, rust,
corrosion, or resin deterioration.
Do not dispose of the product in fire.
Removing from Mounting Rail
To remove the sock et from the mounting rail, insert the tip of
screwdriver in the fixture rail, and move it in the direction shown
below.
Wire connection hole
Release hole
Screwdriver
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
P2RVC-8-O-F P2RVM-020R P2RVM-200B