Subminiature Basic Switch SS-P 103
Subminiature Basic Switch
SS-P
SS Series Compatible Mounting with
a Simple Construction and Easy-to-Use
Design Concept
Insert molded base and improved case-to-base seal
provides enhanced resistance to flux.
Switch rating of 3 A at 125 VAC possible with a single-leaf
movable spring. Models for micro loads with gold crossbar
contact are also available.
Solder, quick-connect terminals (#110), and PCB terminals
are available, including even-pitched PCB terminals.
RoHS Compliant.
Ordering Information
.
Model Number Legend
Terminals Solder terminals Quick-connect
terminals (#110)
PCB terminals
Rating Actuator Uneven pitch Even pitch
3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB
Hinge lever SS-3GLP SS-3GLPT SS-3GLPD SS-3GLPB
Simulated roller lever SS-3GL13P SS-3GL13PT SS-3GL13PD SS-3GL13PB
0.1 A Pin plunger SS-01GP SS-01GPT SS-01GPD SS-01GPB
Hinge lever SS-01GLP SS-01GLPT SS-01GLPD SS-01GLPB
Simulated roller lever SS-01GL13P SS-01GL13PT SS-01GL13PD SS-01GL13PB
SS- P
1. Ratings
3: 3 A at 125 VAC
01: 0.1 A at 30 VDC
2. Contact Gap
G: 0.5 mm
3. Actuator
None: Pin plunger
L: Hinge lever
L13: Simulated roller lever
4. Terminals
None: Solder terminals
T: Quick-connect terminals (#110)
D: PCB terminals (Uneven pitch)
B: PCB terminals (Even pitch)
3 421
104 Subminiature Basic Switch SS-P
Specifications
Characteristics
Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values
apply at the total travel position. Contact opening or closing time is within 1 ms.
Ratings
Note: The electrical rating applies under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/minute
Approved Standards
UL Recognized (File No. E41515)
CSA Certified (UL approval)
EN61058-1 - - VDE approval
(File No. 40008425)
Testing conditions: 5E4 (50,000 operations), T55 (0°C to 55°C)
Note: The rated values approved by each of the safety standards
(e.g. UL, CSA) may be different from the performance charac-
teristics individually defined in this catalog.
Contact Specifications
Note: Minimum applicable loads are indicated by N standard refer-
ence values. This value represents the failure rate at a 60%
60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6 / operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
Operating speed 0.1 mm to 1 m/s (for pin plunger models)
Operating frequency Mechanical: 300 operations/min
Electrical: 30 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance SS-3P: 50 mΩ max.
SS-01P: 100 mΩ max.
Dielectric strength (See note 2) 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarities
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and
between each terminal and non-current-carrying metal parts
Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (See note 3) Destruction: 1,000 m/s2 (approx. 100 G) max.
Malfunction: 300 m/s2 (approx. 30 G) max.
Degree of protection IEC IP40
Degree of protection against electrical shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature 25°C to 85°C (at 60% RH max.) with no icing
Ambient operating humidity 85% max. (for 5°C to 35°C)
Life expectancy Mechanical: 1,000,000 operations min. (60 operations/min)
Electrical: SS-3P: 70,000 operations min. (20 operations/min, 125 VAC)
100,000 operations min. (20 operations/min, 30 VDC)
SS-01P: 200,000 operations min. (20 operations/min)
Weight Approx. 1.6 g (for pin plunger models)
Model SS-3P SS-01P
Rated voltage Item Resistive load
125 VAC 3 A 0.1 A
30 VDC 3 A 0.1 A
Rated Voltage SS-3P SS-01P
125 VAC 3 A 0.1 A
30 VDC 3 A 0.1 A
Rated Voltage SS-3P SS-01P
125 VAC 3 A 0.1 A
30 VDC 3 A 0.1 A
Item SS-3P SS-01P
Specification Rivet Crossbar
Material Silver alloy Gold alloy
Gap (standard value) 0.5 mm
Minimum applicable
load (see note) 160 mA at 5 VDC
1 mA at 5 VDC
Subminiature Basic Switch SS-P 105
Engineering Data
Mounting Holes
PCB Mounting Dimensions (Reference - uneven spacing)
PCB Mounting Dimensions (Reference - even spacing)
Panel Mounting
All switches may be panel mounted using M2.3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.23 to 0.26 N·m
Contact Form
Dimensions
Terminals
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. Terminal plate thickness is 0.5 mm for all models.
Solder Terminals Quick-connect Terminals (#110)
PCB Terminals (Uneven pitch) PCB Terminals (Even pitch)
16.1±0.1
Three, 1.35 to 1.5 dia.
8.8±0.1
7.62±0.1 7.62±0.1 Three, 1.35 to 1.5 dia.
9.5±0.1
Two, 2.4-dia. mounting holes or M2.3 screw holes
COM NO NC
SPDT
15.5 Three, 1.6-dia. holes
8.55
3.3±
0.1
0.5
7.55±
0.2
2.15
7.3
3-2.8
3.3±
0.1
0.5
7.55±
0.2
11 7.1
7.6±
0.2
7.6±
0.2
3-0.8
3-1.2
8.8±
0.2
16.1±
0.2
3.3±
0.1
0.5
1.3
3.91.8
7.55±
0.2
(5.25)
1.85
3-0.8
3-1.2
7.62±
0.2
7.62±
0.2
3.3±
0.1
0.5
1.3
3.91.8
7.55±
0.2
(4.82)
106 Subminiature Basic Switch SS-P
Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2.
The following illustrations are for solder terminal models. Refer to “Terminals” for models with quick-connect terminals (#110) and PCB terminals.
3. The operating characteristics are for operation in the A direction( )
Pin Plunger Models
SS-3GP
SS-01GP
19.8±0.2
5.15 9.5±0.1
15.5 Three, 1.6 dia. holes
8.55
3.3±0.1
3.5
7.7
0.5
6.4±0.2
6.9
7.55±0.2
2
PT
OP
2.35+0.075 dia.
0.05
2.5±0.07 dia.
2.15
7.3
A
2.35+0.075
0.05
Characteristics SS-3GP SS-01GP
OF max. 153 gf
RF min. 20 gf
PT max. 0.6 mm
OT min. 0.4 mm
MD max. 0.15 mm
OP 8.4 ± 0.3 mm
Hinge Lever Models
SS-3GLP
SS-01GLP
19.8±
0.2
5.15 9.5±
0.1
15.5
8.55
FP
OP
0.5
6.4±
0.2
6.9
14.5
t=0.3 Stainless-steel lever
2.15
7.3
A
3.3±
0.1
7.7
Three, 1.6 dia. holes
2.35
+0.075
0.05
2.35
+0.075
dia.
0.05
2.5±
0.07
dia.
3.6
Characteristics SS-3GLP SS-01GLP
OF max. 51 gf
RF min. 5 gf
OT min. 1.0 mm
MD max. 0.8 mm
FP max. 13.6 mm
OP 8.8 ± 0.8 mm
Simulated Roller Lever Models
SS-3GL13P
SS-01GL13P
5.15
15.5
8.55
FP
OP
0.5
6.9
R1.2
15.8
2.15
7.3
A
7.7
19.8±
0.2
9.5±
0.1
6.4±
0.2
t=0.3 Stainless-steel lever
3.3±
0.1
Three, 1.6 dia. holes
2.35
+0.075
0.05
2.35
+0.075
dia.
0.05
2.5±
0.07
dia.
3.6
Characteristics SS-3GL13P SS-01GL13P
OF max. 51 gf
RF min. 5 gf
OT min. 1.0 mm
MD max. 0.8 mm
FP max. 15.5 mm
OP 10.7 ± 0.8 mm
Subminiature Basic Switch SS-P 107
Precautions
Correct Use
Mounting
Mount the Switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the Switch, resulting in faulty operation or
breakage in the housing.
Operating Stroke Setting
Take particular care in setting the operating stroke for the pin plunger
models. Make sure that the operating stroke is 60% to 90% of the
rated OT distance. Do not operate the actuator exceeding the OT dis-
tance, otherwise the life expectancy of the Switch may be shortened.
Using Microloads
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for micro-
loads and that operate in the following range;
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, it may increase contact
wear and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
Cautions
Handling
Turn OFF the power supply before mounting or removing the Switch,
wiring, or performing maintenance or inspection. Failure to do so may
result in electric shock or burning.
Solder Terminal Connection
When soldering lead wires to solder terminals, first insert the lead
wire conductor through the terminal hole and then solder.
Make sure that the temperature at the tip of the soldering iron is
350 to 400°C. Do not take more than 3 seconds to solder the switch
terminal, and do not impose external force on the terminal for 1 min
after soldering. Improper soldering involving an excessively high
temperature or excessive soldering time may deteriorate the charac-
teristics of the Switch.
Quick-Connect Terminals
Wire quick-connect terminals (#110) with receptacles. Insert the ter-
minals straight into the receptacles. Do not impose excessive force
on the terminal in the horizontal direction, otherwise the terminal may
be deformed or the housing may be damaged.
Use appropriate #110 QC connectors, made by Nippon Tanshi or
Tyco Electronics, to mate with the quick-connect versions of the
switch. These connectors are not sold by OMRON. Contact Nippon
Tanshi or Tyco Electronics to purchase these connectors.
PCB Terminal Connection
When using automatic soldering baths, we recommend soldering at
260±5°C within 5 seconds. Make sure that the liquid surface of the
solder does not flow over the edge of the board.
When soldering by hand, as a guideline, solder with a soldering iron
with a tip temperature of 350 to 400°C within 3 seconds, and do not
apply any external force for at least 1 minutes after soldering. When
applying solder, keep the solder away from the case of the Switch
and do not allow solder or flux to enter the case.
Insulation Distance
Use a separator between the switch and metal mounting panels, to
ensure proper dielectric characteristics are achieved.
Voltage (V)
30
24
12
5
0
1 10 100 1,000
Current (mA)
0.1
1 mA
Operating
range for
general-
load models
SS-3P
Operating range
for micro load
models SS-01P
26 mA0.16 mA
100 mA 160 mA
Inoperable
range
100 mA
Subminiature Basic Switch SS-P