16 Specifications are subject to change without notice
Industrial Relay
Type RCP
Monostable
8 or 11-pin socket mounting
2 or 3 change over contacts
Long life (minimun 100.000 electrical operations)
at 10 A 250 VAC /30 VDC
Switching capacity 12 A (5x104cycles)
AC coils 6 to 230 VAC
DC coils 6 to 110 VDC
Matched sockets available
Standard with LED, Push with arm and Flag
IP 40
Conform to CE low voltage directive
IMQ, UL, TÜV, CSA approved
RCP
Type
No. of pins
Contact code
Rated coil voltage
DC / AC
Product Description Ordering Key RCP 8 002 24 DC
Contact code
002
003
Contact rating
10 A
10 A
Contact configuration
2 change over contacts (DPDT {2-form C})
3 change over contacts (3PDT {3-form C})
Type Selection
The RCP relay can be used
for a wide range of industrial
applications.
Available in 2 or 3 change-
over contact configuration,
Octal or Undecal version.
At 20°C At 40°C
Nominal Pick-up Drop-out Pick-up Drop-out Coil
voltage voltage voltage voltage voltage resistance
VDC VDC VDC VDC VDC
6 4.8 0.6 5.2 0.6 23.5 ±10%
12 9.6 1.2 10.3 1.3 95.0 ±10%
24 19.2 2.4 20.7 2.6 430.0 ±10%
48 38.4 4.8 41.4 5.1 1630.0 ±15%
60 45.0 6.0 48.6 6.4 3000.0 ±15%
100 80.0 10.0 86.4 10.8 6800.0 ±15%
110 88.0 11.0 95.0 11.8 6800.0 ±15%
Coil Characteristics, DC
At 20°C At 40°C
Nominal Pick-up Drop-out Pick-up Drop-out Coil
voltage voltage voltage voltage voltage resistance
VAC VAC VAC VAC VAC
6 4.8 1.8 5.2 1.9 40.0 ±10%
12 9.6 3.6 10.3 3.8 160.0 ±10%
24 19.2 7.2 20.7 7.7 650.0 ±10%
48 38.4 14.4 41.4 15.5 2600.0 ±15%
115/120 88.0 36.0 95.0 38.8 11000.0 ±15%
230 176.0 72.0 190.0 77.7 11000.0 ±15%
Coil operating range: see diagram n° 1 pag. 18
Coil Characteristics, AC
Specifications are subject to change without notice 17
RCP8 . . . .
RCP11 . . . .
RCP8 . . . .
RCP11 . . . .
Dimensions
35.5
35.5
56 13
8
1
2
3
45
6
7
8
1
2
6
7
3
45
8
Wiring Diagrams
Industrial Relay
Type RCP
Monostable
35.5
35.5
56 13
8
1
10
2
3
4
5
6
7
8
9
11
3
4
5
8
7
10
2
111
6
9
Contact Characteristics
Arrangement 002 / 003
Contact rating
(with resistive load) 10 A - 250 VAC / 30 VDC
UL rating 10 A - 250 VAC / 30VDC
1/3HP at 240 VAC
Usually rating (1x105ops) 10 A - 250 VAC / 30 VDC
Max. rating (5x104ops) 12 A - 250 VAC / 30 VDC
Material Silver alloy
Current
Max. switching current 10 A
Initial contact resistance 50 m(at 1 A 6 VDC)
Max. switch. voltage 250 VAC / 30 VDC
Max. switch. power 2500 VA / 300 W
Life
Electrical life 1x105ops
Mechanical life 1x107ops
Insulation
Test Voltage (1 min.)
Between coil and contacts 3750 VAC Vr.m.s
Between open contacts 750 VAC Vr.m.s
Contact/Contact 1250 VA Vr.m.s
Initial insulation resistance 500 M- 500 VAC
Insulation
according to EN61810-5
Rated insulation voltage 250 V
Impulsive insulation voltage 3.6 KV
Pollution degree 2
Overvoltage category III
General Data
Nominal coil power 1.5 W / 2.5 VA
Operating time
(At nominal voltage) 30 ms max.
Release time
(At nominal voltage) 20 ms max.
Temperature rise
(At nominal voltage) -40° C to +55° C
Ambient temperature +50° C
Vibration resistance 10 to 55 Hz 1.5 mm
Shock resistance
Funktional 100 m/s2 /10 g
Destructive 500 m/s2 /50 g
Humidity 98%, +40°C%
Termination Octal/Undecal-type plug
Construction Dust cover
Weight ~ 85 g
0 5 10 50 100 500 1000
0.1
0.5
1
10
5
0
18 Specifications are subject to change without notice18 Specifications are subject to change without notice
U.S.A. CANADA GERMANY ITALY
Diagrams
0 +10 +20 +30 +40 +50 +60
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
Approvals
1 Coil Operating
Range
3 Max.
DC load
breaking
capacity
Ambient temperature (°C)
UB/ UN
Rated Voltage (V) Rated Voltage (V)
Rated Current (A)
0 5 10 50 100 500 1000
0.1
0.5
1
10
5
0
Rated Current (A)
AC Resistive load
DC Resistive load
2 Electrical
life
0123456789101112
10
0.1
0.5
5
00.5
00.1
1
0
Switching Current (A) Switching Current (A)
Number of operations (X 106ops)
Number of operations (X 106ops)
AC inductive load
250 VAC COS ϕ = 0,4
DC inductive load
28 VDC — = 40ms
L
R
AC inductive load
COS ϕ = 0,4
DC inductive load
— = 40ms
L
R
DC inductive load
— = 7ms
L
R
DC resistive load
28 VDC
AC resistive load
250 VAC