Surge arrester
3-electrode arrester
Series/Type: T90-A90XG
Ordering code: B88069X5860T902
Date: 2015-09-09
Version: 04
EPCOS AG 2015. Reproduction, publication and dissemination of this publicatio n, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Content of head er bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
(header 1 + top left bar): Surge arrester
Identification/Classification 2
(header 2 + bottom left header bar): 3-electrode arrester
Ordering code: (top right header b a r) B88069X5860T902
Series/Type: (bottom right header bar) T90-A90XG
Preliminary data (optional):
Department: PPD AB PD / PPD AB PM
Date: 2015-09-09
Version: 04
Surge arrester B88069X5860T902
3-electrode arrester T90-A90XG
PPD AB PD / PPD AB PM 2015-09-09
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.
Features Applications
Very small size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Modem
Data lines
Electrical specifications
DC spark-over voltage 1) 2) 3)
90
20 V
%
Impulse spark-over voltage 3)
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs - for 99% of measured values
- typical values of distribution
< 450
< 350
< 600
< 500
V
V
V
V
Service life
10 operations 50 Hz; 1 s 4) 10 A
10 operations [5× (+) & 5× (–)] 8/20 µs
4) 10 kA
2 operation 10/350 µs
4) 1 kA
300 operations [150× (+) & 150× (–)] 10/1000 µs 4) 200 A
Insulation resistance at 50 VDC 3) > 1 G
Capacitance at 1 MHz 3) < 1.5 pF
Transverse delay time 5) < 0.2 µs
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
< 0.5
~ 70
V
A
V
Weight ~ 1.2 g
Operation and storage temperature 40 ... +90 °C
Climatic category (IEC 60068-1) 40/090/21
Marking, blue negative
90 YY O
90 - Nominal voltage
YY - Year of production
O - Non radioactive
Certifications UL 497B (E163070)
Remarks on next page
Surge arrester B88069X5860T902
3-electrode arrester T90-A90XG
PPD AB PD / PPD AB PM 2015-09-09
Please read Cautions and warnings and Page 3 of 5
Important notes at the end of this document.
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
3) Tip or ring electrode to center electro de
4) Total current through center electrode, half value through tip respectively ring electrode.
5) Test according to ITU-T Rec. K.12
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
Dimensional drawing in mm
Ordering code and packing advice
B88069X5860T902 = SMD-tape with 900 pcs.
Surge arrester B88069X5860T902
3-electrode arrester T90-A90XG
PPD AB PD / PPD AB PM 2015-09-09
Please read Cautions and warnings and Page 4 of 5
Important notes at the end of this document.
Cautions and warnings
Do not operate surge arresters in power supply networks, whose maximum operating voltage
exceeds the minimum spark-over voltage of the surge arresters.
If the contacts of the surge arresters are defective, current load can cause sparks and loud
noises.
Surge arresters may become hot in the event of longer periods of current stress (burn risk). In the
event of overload the connectors may fail or the component may be destroyed.
Surge arresters must be handled with care and must not be dropped.
Do not continue to use damaged surge arresters.
Display of ordering codes for EPCOS products
The ordering code for one and the same EPCOS product can be represented differently in data
sheets, data books, other publications, on the EPCOS website, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of
the respective products. Detailed information can be found on the Internet under
www.epcos.com/orderingcodes
Important notes
Page 5 of 5
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell,
MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT,
SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries.
Further information will be found on the Internet at www.epcos.com/trademarks.