DC/DC Converter
G_S-1WR2 & H_S-1WR2 Series
2017.04.17-A/4 Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Selection Guide
Certification
Part No.
Input Voltage (VDC)
Output
Efficiency
(%,Min./Typ.)
@ Full Load
Nominal
(Range)
Output Voltage(VDC)
Output Current
(mA)(Max./Min.)
--
H0305S-1WR2
3.3
(2.97-3.63)
5
200/20
67/71
UL/CE
G0505S-1WR2
5
(4.5-5.5)
±5
±100/±10
74/78
G0509S-1WR2
±9
±56/±6
76/80
G0512S-1WR2
±12
±42/±5
70/74
G0515S-1WR2
±15
±34/±4
72/76
UL/CE/CB
H0503S-1WR2
3.3
303/31
69/73
H0505S-1WR2
5
200/20
74/78
H0512S-1WR2
12
84/9
72/76
H0515S-1WR2
15
67/7
72/76
UL/CE
G1205S-1WR2
12
10.8-13.2
±5
±100/±10
73/77
G1209S-1WR2
±9
±56/±6
76/80
G1212S-1WR2
±12
±42/±5
69/73
G1215S-1WR2
±15
±34/±4
71/75
UL/CE/CB
H1205S-1WR2
5
200/20
73/77
H1212S-1WR2
12
84/9
77/81
H1215S-1WR2
15
67/7
77/81
UL
G1515S-1WR2
15
13.5-16.5
±15
±34/±4
68/72
UL/CE
G2405S-1WR2
24
21.6-26.4
±5
±100/±10
71/75
G2409S-1WR2
±9
±56/±6
75/79
G2412S-1WR2
±12
±42/±5
72/76
G2415S-1WR2
±15
±34/±4
72/76
UL/CE/CB
H2405S-1WR2
5
200/20
72/76
H2412S-1WR2
12
84/9
74/78
H2415S-1WR2
15
67/7
74/78
Note:* The capacitive loads of positive and negative outputs are identical.
1W, Fixed input voltage , 4200VAC or 6000VDC isolated
& unregulated positive-negative dual/single output
CB Patent Protection RoHS
FEATURES
SIP package
High efficiency up to 81%
Reinforced insulation
The patient leakage current: Max 2µA
Isolation voltage: 4200VAC or 6000VDC
Operating temperature range:-40to +85
Internal surface mounted design
International standard pin-out
EN60601-1, ANSI/AAMI ES60601-1approval
1xMOPP/2xMOOP
IEC60950 approval
G_S-1WR2 & H_S-1WR2 series meet reinforced insulation requirements. They are specially designed for applications where require compact
size, high isolation, low isolation capacitor and low leakage current power. They are widely used in medical, electricity, IGBT driver and so
on. They are suitable for:
1.Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2.Where isolation is necessary between input and output (isolation voltage 4200VAC or 6000VDC);
3.Where do not has high requirement of line regulation and the ripple & noise of the output voltage;
Such as: Medical collection and isolation, High voltage collection circuit, IGBT-driven circuits, etc.
DC/DC Converter
G_S-1WR2 & H_S-1WR2 Series
2017.04.17-A/4 Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Input Current (no-load/full load)
3.3V input
--
45/426
70/--
mA
5V input
--
35/274
60/--
12V input
--
15/114
40/--
15V input
--
18/93
40/--
24V input
--
10/56
25/--
Surge Voltage (1sec. max.)
3.3V input
-0.7
--
7
VDC
5V input
-0.7
--
9
12V input
-0.7
--
18
15V input
-0.7
--
21
24V input
-0.7
--
30
Reflected Ripple Current*
--
0.2
--
A
Input Filter
Capacitor filter
Hot Plug
Unavailable
Note: *Reflected ripple current testing method please see DC-DC Converter Application Notes for specific operation.
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
See tolerance envelope curve (Fig. 1)
Line Regulation
Input voltage change: ±1%
3.3V output
--
--
±1.5
--
Others
--
--
±1.2
Load Regulation
10%-100% load
3.3V/5V output
--
--
20
%
Others
--
--
15
Ripple & Noise*
20MHz bandwidth
3.3V output
--
80
150
mVp-p
Others
--
70
120
Temperature Coefficient
100% full load
--
±0.02
--
%/
Output Short Circuit Protection**
--
--
3
s
Note: *Ripple and noise tested with “parallel cable method, please see DC-DC Converter Application Notes for specific operation methods.
**Supply voltage must be discontinued at the end of short circuit duration which less than 3s.
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Insulation Voltage
Input-output, with the test time of 1 minute
4200
--
--
VAC
6000
--
--
VDC
Patient Leakage Current
250VAC50/60Hz
--
--
2
µA
Insulation Resistance
Input-output, isolation voltage 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output, 100KHz/0.1V
--
5
--
pF
Operating Temperature
-40
--
85
Storage Temperature
-55
--
125
Casing Temperature Rise
Ta=25
--
25
--
Pin Welding Resistance
Temperature
Welding spot is 1.5mm away from the casing, 10 seconds
--
--
300
Storage Humidity
Non-condensing
--
--
95
%RH
Switching Frequency
100% load, nominal input voltage
--
100
--
KHz
MTBF
MIL-HDBK-217F@25
3500
--
--
K hours
Transformer Creepage
5
--
--
mm
Transformer Clearance
5
--
--
PCB Creepage & Clearance
5.5
--
--
Note:1. Patient leakage current and reinforced insulation is based on a 250 VAC, 50/60 Hz system input voltage.
2. The UL certification (ANSI/AAMI ES60601-1, File No. E347375) of G_S-1WR2 & H_S-1WR2 series is approved, G_S-1WR2 & H_S-1WR2 series meets
1xMOPP/2xMOOP when system input voltage is with 250VAC , 50/60Hz.
DC/DC Converter
G_S-1WR2 & H_S-1WR2 Series
2017.04.17-A/4 Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Physical Specifications
Casing Material
Black flame-retardant and heat-resistant plastic (UL94 V-0)
Package Dimensions
19.50*9.80*12.50 mm
Weight
4.2g(Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
Conducted emission
CISPR22/EN55022 CLASS B (see Fig. 5 for recommended circuit)
Radiated emission
CISPR22/EN55022 CLASS B (see Fig. 5 for recommended circuit)
EMS
Electrostatic discharge
IEC/EN61000-4-2 Contact ±8KV perf. Criteria B
Product Characteristic Curve
3.3VDC output
-10%
80%
20%
10% 40% 60%
-5%
0
+5%
+10%
+15%
100%
Typ
.
Min.
Max.
-12.5%
-5%
+2.5%
Tolerance Envelope Curve
Output Voltage Accuracy
Output Current Percent
(Nominal Input Voltage)
5VDC output
-10%
80%
20%
10% 40% 60%
-5%
0
+5%
+10%
+15%
100%
Typ
.
Min.
Max.
-7.5%
-2.5%
+2.5%
Tolerance Envelope Curve
Output Cur rent Percent
(Nominal Input Vo ltage)
Output Voltage Accuracy
Other output
-10%
80%
20%
10% 40% 60%
-5%
0
+5%
+10%
+15%
100%
Typ
.
Min.
Max.
-7.5%
-2.5%
+2.5%
Output Cur rent Percent
(Nominal Input Voltage)
Output Voltage Accuracy
Tolerance Envelope Curve
Fig. 1
Operating Temperature( )
Temperature Curve
Output Power Percentage(%)
-40 0 40 85
80
60
100
120
40
20
0
Safe Operating Area
120
Fig. 2
DC/DC Converter
G_S-1WR2 & H_S-1WR2 Series
2017.04.17-A/4 Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important, start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (see Fig. 4).
S in g l e
V in
G N D
+Vo
0 V
D C
C in D C C ou t
D u a l
V in
G N D
+Vo
0 V
D C
C in D C C o ut
C ou t
-Vo
Fig. 3
Single
Vin
GND 0V
+Vo
DC DC
REG REG
Vin
GND
0V
+Vo
DC DC
-Vo
REG
REG
REG
Dual
Fig. 4
Recommended capacitive load value table (Table 1)
Vin
(VDC)
Cin
(µF)
Single
Vout
(VDC)
Cout
(µF)
Dual
Vout
(VDC)
Cout
(µF)
3.3/5
10
3.3/5
10
±5
4.7
12/15
4.7
12
2.2
±9
2.2
24
2.2
15
1
±12/±15
1
2. EMC typical recommended circuit (CLASS B)
Vin
GND
+Vo
-Vo
( )0V
DC/DC LOAD
LDM
C1 C2 C3
Vin
GND
Fig. 5
Recommended typical circuit parameters:
Input voltage (V)
3.3/5/12/15/24
EMI
C1,C2
4.7µF /50V
C3
Refer to the Cout in Fig.3
LDM
6.8µH
3. Output load requirements
In order to ensure the converter can work reliably with high efficiency, the minimum load should not less than 10% rated load when it is used.
If the needed power is indeed small, please parallel a resistor on the output side ( The sum of the efficient power and resistor consumption
power is not less than 10%).
4. For more information please find the application notes on www.mornsun-power.com
DC/DC Converter
G_S-1WR2 & H_S-1WR2 Series
2017.04.17-A/4 Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Dimensions and Recommended Layout
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing
bag number: 58200013;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. The maximum capacitive load offered were tested at input voltage range and full load;
4. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal
input voltage and rated output load;
5. All index testing methods in this datasheet are based on our Company’s corporate standards;
6. We can provide product customization service, please contact our technicians directly for specific information;
7. Specifications are subject to change without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: info@mornsun.cn