80mA 0080 250V 2800 0.4 0.019 • •
100mA 0100 250V 2400 0.5 0.038 • •
125mA 0125 250V 2100 0.5 0.066 • •
150mA 0150 250V 1800 0.5 0.10 • •
200mA 0200 250V 1300 0.6 0.18 • •
250mA 0250 250V 1100 0.7 0.29 • •
300mA 0300 250V 1050 0.7 0.5 • •
400mA 0400 250V 850 0.8 1.0 • •
500mA 0500 250V 650 0.8 1.6 • •
600mA 0600 250V 550 0.8 2.7 • •
700mA 0700 250V 500 0.9 3.7 • •
800mA 0800 250V 400 0.9 5.6 • •
1.00A 1100 250V 350 1.0 9.5 • •
1.25A 1125 250V 300 1.0 15 • •
1.60A 1160 250V 270 1.1 25 • •
2.00A 1200 250V 235 1.1 46 • •
2.50A 1250 250V 215 1.2 83 • •
3.00A 1300 250V 200 1.3 110 • •
3.50A 1350 250V 200 1.3 180 • •
UL
CSA
35A / 250VAC
10kA / 125VAC
50-60Hz
cos
ϕ
= 0.7-0.8
100A / 250VAC
10kA / 125VAC
50-60Hz
cos
ϕ
= 0.7-0.8
MM
MM
MINIAINIA
INIAINIA
INIATURETURE
TURETURE
TURE F F
F F
FUSESUSES
USESUSES
USES
Dimensions (mm)Dimensions (mm)
Dimensions (mm)Dimensions (mm)
Dimensions (mm)
Limits for Pre-arcing TimeLimits for Pre-arcing Time
Limits for Pre-arcing TimeLimits for Pre-arcing Time
Limits for Pre-arcing Time
Permissible continuous operating current is Permissible continuous operating current is
Permissible continuous operating current is Permissible continuous operating current is
Permissible continuous operating current is ≤≤
≤≤
≤ 75 75
75 75
75% at ambient temperature of 23ºC (73.4ºF).% at ambient temperature of 23ºC (73.4ºF).
% at ambient temperature of 23ºC (73.4ºF).% at ambient temperature of 23ºC (73.4ºF).
% at ambient temperature of 23ºC (73.4ºF).
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
PackagingPackaging
PackagingPackaging
Packaging
000: Bulk (1000 pcs.)
002: Bulk (20x10 pcs.)
043: With mounted holder - Tape/Reel (1250 pcs.)
on request
MaterialsMaterials
MaterialsMaterials
Materials
Tube: Glass
End Caps: Nickel-plated brass
Optional Holders: Nickel-plated caps
Tin-plated copper wires
Operating TOperating T
Operating TOperating T
Operating Temperatureemperature
emperatureemperature
emperature
-25ºC to +70ºC (consider de-rating)
Climatic CategoryClimatic Category
Climatic CategoryClimatic Category
Climatic Category
-25ºC/+70ºC/21 days (EN 60068-1..3)
Stock ConditionsStock Conditions
Stock ConditionsStock Conditions
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
Vibration ResistanceVibration Resistance
Vibration ResistanceVibration Resistance
Vibration Resistance
24 cycles at 15 min. each (EN 60068-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
SolderabilitySolderability
SolderabilitySolderability
Solderability
260ºC, ≤ 3 sec. (Wave)
350ºC, ≤ 1 sec. (Hand)
Soldering Heat ResistanceSoldering Heat Resistance
Soldering Heat ResistanceSoldering Heat Resistance
Soldering Heat Resistance
260ºC, 10 sec. (IEC 60068-2-20)
MarkingMarking
MarkingMarking
Marking
, Current Rating, 250VAC, D, 198, Approvals
Unit WeightUnit Weight
Unit WeightUnit Weight
Unit Weight
1.1g (approx.)
2.0g (with leads)
OrderOrder
OrderOrder
Order Qty.Qty.
Qty.Qty.
Qty. Order-Order-
Order-Order-
Order- SeriesSeries
SeriesSeries
Series Amp Code PackagingAmp Code Packaging
Amp Code PackagingAmp Code Packaging
Amp Code Packaging
InformationInformation
InformationInformation
Information Number Number
Number Number
Number
198
UL 248-14, 250VUL 248-14, 250V
UL 248-14, 250VUL 248-14, 250V
UL 248-14, 250V, D, D
, D, D
, D
TT
TT
Time-Current Characteristicime-Current Characteristic
ime-Current Characteristicime-Current Characteristic
ime-Current Characteristic
Time Delay (D)
StandardStandard
StandardStandard
Standard
UL 248-14
CSA C22.2 No. 248.14
ApprovalsApprovals
ApprovalsApprovals
Approvals
UL Listed
CSA Certified
FeaturesFeatures
FeaturesFeatures
Features
Visual fault indication
Direct solderable or plug-in versions
Internationally approved
Worldwide availability
WebLinksWebLinks
WebLinksWebLinks
WebLinks
Data SheetData Sheet
Data SheetData Sheet
Data Sheet
http://www.wickmann.com/products/198.pdf
Approval CertificatesApproval Certificates
Approval CertificatesApproval Certificates
Approval Certificates
http://www.wickmann.com/approvals
Time-Current CurveTime-Current Curve
Time-Current CurveTime-Current Curve
Time-Current Curve
http://www.wickmann.com/itcurves
PackagingPackaging
PackagingPackaging
Packaging
http://www.wickmann.com/pack
Further application infos see Fuseology:Further application infos see Fuseology:
Further application infos see Fuseology:Further application infos see Fuseology:
Further application infos see Fuseology:
http://www.wickmann.com/download/
fuseology.pdf
5x20mm / No. 198198
198198
198
Rated Amp Voltage Breaking Voltage Drop Power DissipationMelting Integral Approvals
Current Code Rating Capacity 1.0 x IRated 1.0 x IRated 10 x IRated
max. (mV) max. (W) min. (A2s)
Rated Current 1.35 x IRated 2.0 x IRated
80mA ... 3.00A < 1h 5s ... 120s
3.50A < 1h 12s ... 120s
Specifications are subject