Cyclon Cells and Monoblocs
The Cyclon cells and monoblocs offer versatility of using
2 Volt building blocks to satisfy standard industrial and standby applications through to the most
demanding requirements, where extreme performance in harsh environments is necessary. DMS
technologies can also provide a custom build solution for you from product selection, through to design
and finally to manufacture, using Cyclon batteries.
Main Benefits
Exceptional High Rate performance (up to 26C)
Operating temperature range:
Cells: -65ºC to +80ºC
Monoblocs: -40ºC to +40ºC
High shock and vibration resistance
Cycle Life - up to 3000 cycles at 30% DOD
Float Life:
Cells- 15 years at 20ºC
Monoblocs - 10 years at 20ºC
Storage Life greater than 2 years at 25ºC, from full state of charge
Recharge to 95% capacity in under 1 hour
Typical Applications
Telecommunications - Railways - Industrial - Offshore - Utilities - Medical - Garden Equipment - Switch
Tripping
Technical Specifications for 2Volt Single Cells at 25ºC
DMS Part Number Cell Type Volts Nominal (Ah)
Capacity (10hr rate to 1.67VPC) Dimensions mm Weight kg Tabs mm
Diameter Height Height over tabs
9810-0004 D cell (2.5Ah) 2 2.5 34 61 68 0.2 4.75 x 0.64
9860-0004 Tall D cell (4.5Ah) 2 4.5 34 96 103 0.3 4.74 x 0.64
9800-0004 X cell (5.0Ah) 2 5.0 44 73 82 0.4 6.35 x 0.64
9850-0004 E cell (8Ah) 2 8.0 44 100 109 0.6 6.35 x 0.64
9840-0004 J cell (12.5Ah) 2 12.5 52 123 136 0.8 7.92 x 0.81
9820-0004 BC cell (25Ah) 2 25.0 65 159 174 1.7 M8+ M6 -studs