HCX Series
Fully signal conditioned pressure transducer
1/4August 2007 / 026
www.sensortechnics.com
FEATURES
· Pressure ranges from
±5 mbar to 5 bar differential,
1 and 2 bar absolute
· TTL power supply
· 0.5...4.5 V output
· Inline pinning for easy PCB-mounting
· Externally adjustable offset and span
SPECIFICATIONS
Maximum ratings
Excitation voltage
Output current
Source
Sink
T emperature limits
Operating
Storage
Compensated
Lead temperature (2...4 sec. soldering)
Humidity
Proof pressure1
HCXPM005..., HCXM010...
and HCXM020
HCXM050 to HCXM350
all other devices
Tightening torque
(mounting screws M2.5)
ELECTRICAL CONNECTION
4.8 to 15 V
5 mA
5 mA
-20 to 70°C
-40 to 85°C
0 to 50°C
250°C
0 - 95 %RH
700 mbar
1.4 bar
2 x rated pressure
10 Ncm
SERVICE
Non-corrosive, non-ionic working fluids,
such as dry air and dry gases. Scale: 1 cm
1 inch
span adj.
(optional)
offset adj.
(optional)
HCX(M)...
23 6
5
4
1
V
-Vs
Vout
+Vs
GND
6
6
HCX Series
Fully signal conditioned pressure transducer
2/4 August 2007 / 026
www.sensortechnics.com
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5 V, RL > 100 k, tamb = 25°C)
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through
three points (offset pressure, full scale pressure and 1/2 full scale pressure).
Change after one year or 1 million pressure cycles.
Thermal effects tested and guaranteed from 0°C to 50°C relative to 25°C. All specifications shown are relative to 25°C.
Span is the algebraic difference between the output at full scale pressure and offset.
Under normal conditions external offset and span calibrations are not needed. In case fine trimming is required, offset
adjustments are possible to lower values only. Do not trim for nominal value minus 150 mV. Span adjustments are
possible to lower pressure range (higher gain). Do not trim for more than 15 % of full scale pressure.
Specification notes:
1.
2.
3.
4.
5.
6.
scitsiretcarahC.niM.pyT.xaMtinU
erusserpgnitarepO...6D500MPXCH ...6D010MXCH ...6D010MPXCH ...6D020MXCH ...6D050MXCH ...6D001MXCH ...6D053MXCH ...6...100XCH ...6...200XCH ...6...500XCH
5-001-0
0
0
0
0
0
0
5
01010205 001 053 0001 0002 0005
rabm
tesffoerusserporeZ...MPXCHlla ...6D020MXCH/...6D010MXCH secivedrehtolla
04.2 04.0 54.0
05.2 05.0 05.0
06.2 06.0 55.0 V
napS
5
...MPXCH secivedrehtolla 59.1 59.3 0.2 0.4 50.2 50.4
tuptuoelacslluF 5.4
erusserpdeificepstsewoltatuptuO ylno...MPXCH 5.0
)C°05ot0(stceffelamrehT
4
napsdnatesffodenibmoC ...6D500M...PXCH ...6D050MXCHot...6D010MXCH ...6D053MXCH,...6D001MXCH secivedrehtolla
02.0 21.0 01.0 50.0
C°/OSF%
)LSB(siseretsyhdnaytiraenil-noN
2
...6D020MXCH secivedrehtolla 5.0 1.0 0.1 5.0 OSF%
ytilibatsmretgnoL
3
2.0±
ecnadepmituptuO 05
noitcejerylppusrewoPtesffO napS 50.0 30.0 V/OSF%
)daolon(noitpmusnocrewoP 05Wm
HCX Series
Fully signal conditioned pressure transducer
3/4August 2007 / 026
www.sensortechnics.com
OUTLINE DRAWING
HCX(M)...6H, HCXPM...6H
HCX(M)...6V
mass: 14 g dimensions in mm
mass: 14 g dimensions in mm
P1: High pressure port for
5 mbar and 10 mbar devices
P2: High pressure port for
all other devices
(forward gage)
P1: High pressure port for
5 mbar and 10 mbar devices
P2: High pressure port for
all other devices
third angle projection
third angle projection
Top view
Top view
P2 P1
654321
SENSORTECHNICS
NOM 35 NOM Ø 2.6
NOM 29
3
NOM 19 NOM 25
3
5.25
15 ±0.2
25
12 ± 0.5 NOM
5 x 2.54
max. 13
NOM 26
min. 3.2
Ø 3.0
Ø 4.4
Ø 5.4
pin 1
NOM 2.54
pin size 0.5 x 0.35
Ø 4.8
Ø 6.3
pin size 0.5 x 0.35
39.6 +0.5/-0.3
pin 1
NOM
5 x 2.54
NOM 6.8
654321
SENSORTECHNICS
P1P2
NOM 35
NOM 29
3
3
NOM 19 NOM 25
Ø 3.0
Ø 4.4
Ø 5.4
Ø 6.3
Ø 4.8
12 ±0.5
max. 13
25
15 ±0.2
min. 3.2
NOM 2.54
NOM Ø 2.6
HCX Series
Fully signal conditioned pressure transducer
4/4 August 2007 / 026
www.sensortechnics.com
ORDERING INFORMA TION
Part number / Package version
Side facing ports
HCXPM005D6V
HCXM010D6V
HCXPM010D6V
HCXM020D6V
HCXM050D6V
HCXM100D6V
HCXM350D6V
HCX001D6V
HCX002D6V
HCX005D6V
HCX001A6V
HCX002A6V
Top facing ports
HCXPM005D6H
HCXM010D6H
HCXPM010D6H
HCXM020D6H
HCXM050D6H
HCXM100D6H
HCXM350D6H
HCX001D6H
HCX002D6H
HCX005D6H
HCX001A6H
HCX002A6H
Pressure range
differential / gage devices
0 to ±5 mbar
0 to 10 mbar
0 to ±10 mbar
0 to 20 mbar
0 to 50 mbar
0 to 100 mbar
0 to 350 mbar
0 to 1 bar
0 to 2 bar
0 to 5 bar
absolute devices
0 to 1 bar
0 to 2 bar
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.