DMR20-4/20 Series Loop-Powered, 4-20 mA LED Display Process Monitors with 2.5V Loop Drop FEATURES 2.5V maximum loop-drop (125 burden) for red LED model! High-quality, 20-turn, span (gain) and zero (offset) Self-powered directly from 4-20 mA current loop, no external power source needed Fits round 1.20 inch [30.5 mm] cutouts; less than 1.00 inch [<25.4 mm] behind-the-panel depth Easy-to-read, 0.30 inch [7.6 mm] high LED digits with excellent display brightness; available in red or green LEDs Supplied with EPDM rubber gasket and hex nut High-quality, 20-turn, span (gain) and zero (offset) adjustments Gold-plated DIP-switch for range and decimal points: Reliable screw-terminal input connections Rugged, polycarbonate, one-piece package Protected against dust and water submersion to IP67/NEMA 6 Murata's new DMR20-4/20 loop-powered digital process monitors feature a large, easy-to-read, bright LED display. All operating power is derived directly from the current loop itself--no external power source is required! The large, 0.30 [7.6 mm] digits exhibit uniform intensity over the entire 4-20 mA operating range. Unlike other loop-powered LED displays, the total maximum loop voltage drop for the red LED model is 2.5V! Users no longer have to settle for difficult-to-read LCD displays in loop-powered applications. Both gain (span) and offset (zero) adjustments are performed with on-board, precision, 20-turn potentiometers. All decimal-point and range-change selections are made on a six-position DIP switch featuring vibration-resistant, gold-plated contacts. Unlike competitive meters, there are no jumpers or solder gaps to open or close. Connections to the current loop are made via a reliable, two-position, screw-type terminal block. The DMR20-4/20's DIP-switch and potentiometers accommodate hundreds of different input-current/output-reading combinations. This versatility eliminates the need to order more costly, long-lead-time customs meters in applications in which several different-range meters are required. The round plastic housing fits standard 1.20" [30.5mm] panel cutouts. An EPDM rubber gasket and hex nut simplify installation and provide IP67/NEMA 6 protection to environmental dirt and moisture. SIMPLIFIED SCHEMATIC DIAGRAM For full details go to: http://www.murata-ps.com/en/support/rohscompliance.html www.murata-ps.com/support MPM_DMR20-4/20.A01 Page 1 of 5 DMR20-4/20 Series Subminiature 4-20 mA Loop-Powered 31/2 Digit LED Process Monitors OPERATING AND SETUP INSTRUCTIONS Performance/Functional Specifications Typical at TA = +25C, unless otherwise noted. Current Loop Input DMR20-4/20S (Unipolar Reading Model) Min. Typ. Max. Units +4 - +20 mA Input Impedance - 175 Loop Voltage Drop - Red LED - 2.2 2.5 Volts 3.2 3.5 Volts - 40 mA Full Scale Input Range Loop Voltage Drop - Green LED Overcurrent Protection - Performance Sampling Rate 2.5 readings per second Accuracy (1 minute warm-up) Temperature Drift (0 to +60C) 0.05% FS 2 Count - 0.15 0.3 Cnts/C Display Display Type and Size 31/2 digit, 0.30" / 7.6 mm high red LED Polarity Indication "-" for negative reading Overrange Indication "-1 "1 " for negative Vin " for positive Vin Storage Temperature Humidity (non-condensing) 0 - +60 C -40 - +75 C 0 - 85 % Case Material Polycarbonate Weight 1. Set R7 (full scale span/gain adjust) and R3 (zero/offset adjust) fully counterclockwise, roughly 22 turns, and set SW1-SW6 to OFF. 2. Select DIP switch setting #2 in Table 1. 3. Apply a precision 4 mA input to TB1 with proper polarity, and adjust R3 until the meter's display reads "000." 4. Apply a precision 20 mA input and adjust R7 until the meter's display reads "1000." Repeat steps 3 and 4 to make sure the adjustments do not affect one another. 5. If required, select the appropriate decimal point by setting SW1 and SW2 per the settings shown in Table 3. Physical/Environmental Operating Temperature As shipped, the DMR20-4/20S is factory calibrated to read "000" for a 4 mA input and "1000" for a 20 mA input. The following worst-case procedure assumes the DMR20-4/20S is completely misadjusted, i.e., both potentiometers and the DIP switches are randomly set .When performing DIP-switch settings, be sure the DIP switch's small actuators are firmly engaged in their fully-ON or fully-OFF positions. NOTE: If a display reading other than "000" to "1000" is desired, refer to DIP-Switch Settings Table 1 below for SW3- SW6 settings. Table 1 DMR20-4/20S (Unipolar Model) DIP-Switch Settings 0.65 ounces (18.5 grams) The DMR20-4/20, using any of the DIP-switch settings described above, can withstand overcurrents, including those resulting from accidental reverse-polarity connections, up to 40 mA without sustaining any damage. Display Readings 4 mA 20 mA SW3 SW4 SW5 SW6 1 000 to 1200-1999 Off Off Off Off Because DMR20-4/20 loop-powered meters employ active circuitry to convert the loop current into a voltage; the meters' effective series impedance varies in a manner that maintains the loop voltage drop relatively constant over the full 4-to20 mA current range. Listed input impedance specification applies at 20 mA with all DIP switches set to OFF. 2 000 to 750-1350 On Off Off Off 3 000 to 500-850 Off On Off Off 4 000 to 350-600 Off Off On Off 5 000 to 250-350 On On On Off When looking up DIP-switch settings in the following Tables and the desired display readings can be achieved with either of two different settings, using the higher setting # will produce less sensitive offset (R3) and span (R7) adjustments. Please keep in mind that the accuracy specification of 2 counts means it may not always be possible to obtain the exact desired display reading. 6 000 to 150-250 On Off On On Ordering Information DMR20-4/20S-R-C Unipolar, loop-powered red LED meter DMR20-4/20S-G-C Unipolar, loop-powered green ED meter DMR20-4/20B-R-C Unipolar, loop-powered red LED meter Note: An M30 x 1.5 nylon metric hex nut and EPDM sealing gasket are supplied with each meter. The "-C" suffix indicates RoHS compliance Panel Knockout Tools: DMR20-1-KP DMR20-2-KP DMR20-3-KP 1.22" [30.9 mm] punch (no keying notch) 1.21" [30.7 mm] punch with 4 keying notches Keyway Punch tool Examples (DMR20-4/20S-Unipolar Models) 1. Desired display readings are: 4 mA = "0.00" 20 mA = "6.00" Use DIP-switch setting #3 in Table 1 and enable decimal point DP2 by setting SW1 to `On' and SW2 to `Off'. Apply 4 mA and adjust R3 so the display reads "0.00." Apply 20 mA and adjust R7 so the display reads "6.00." 2. Desired display readings are: 4 mA="000" 20 mA ="800" Use DIP-switch setting #2 in Table 1. Apply 4 mA and adjust R3 so the display reads "000." Apply 20 mA and adjust R7 so the display reads "800." For these display readings, no decimal points are used so set SW1 and SW2 both to On. www.murata-ps.com/support MPM_DMR20-4/20.A01 Page 2 of 5 DMR20-4/20 Series Subminiature 4-20 mA Loop-Powered 31/2 Digit LED Process Monitors 3. Desired display readings are: Examples (DMR20-4/20B-Bipolar Model) 4 mA =."000" 12 mA =."250" 1. Desired display readings are: This example is not as straightforward as the previous two. Notice that 12 mA is exactly halfway between 4 mA and 20 mA. If we assume that the input could go up to 20 mA, the display reading would then be: 2 x. 250 or ."500." From Table 1 we can now select DIP-switch setting #4 and enable DP1 by setting SW1 to Off and SW2 to On. Apply 4 mA and adjust R3 so the display reads "000." Apply 12 mA and adjust R7 so the display reads "250." DMR20-4/20B (Bipolar Reading Model) 4 mA="-1.00" 20 mA ="1.00" Use DIP-switch setting #5 in Table 2 and enable decimal point DP2 by setting SW1 to `On' and SW2 to `Off'. Apply 12 mA and adjust R3 so the display reads "0.00." Apply 20 mA and adjust R7 so the display reads "1.00." Apply 4 mA and verify that the display reads "-1.00," readjust R3 and R7 if necessary. 2. Desired display readings are: 4 mA="-450" 20 mA ="450" The DMR20-4/20B's zero-offset circuit differs from the unipolar `S' model described above in that with the `B' model, a half-scale 12 mA input is normally set to display "000." Therefore, all of the DIP-switch settings in Table 2 assume a reading of "000" is desired with a 12 mA input. Use DIP-switch setting #2 in Table 2. Apply 12 mA and adjust R3 so the display reads "000." Apply 20 mA and adjust R7 so the display reads "450." Apply 4 mA and verify that the display reads "-450." Repeat adjustment procedure if necessary. For these display readings, no decimal points are used, so set SW1 and SW2 to On. When configuring the DMR20-4/20B for the first time, or when selecting a new range, set both R3 and R7 fully counterclockwise (roughly 22 turns) to their minimum offset/minimum-span positions, respectively. Then select the desired readings from Table 2 and configure DIP-switches SW3, SW4, SW5, and SW6 accordingly. 3. Desired display readings are: 4 mA="-650" 20 mA ="650" The procedure below illustrates how to calibrate the DMR20-4/20B to its factory-calibrated readings of "-1000" with a 4 mA input and "1000" with a 20 mA input. When performing DIP-switch settings, be sure the DIPswitch's small actuators are firmly engaged in their fully-ON or fully-OFF positions. Select DIP-setting # 1 in Table 2. Apply 12 mA and adjust R3 so the display reads "000." Apply 20 mA and adjust R7 so the display reads "650." Apply 4 mA and verify that the display reads "-650." Repeat adjustment procedure if necessary. For these display readings, no decimal points are used, so set SW1 and SW2 to On. 1. Set both R3 and R7 fully counterclockwise. 2. Select DIP-switch setting #1 from Table 2. Table 3 Decimal Point Settings (All Models) 3. Apply a precision 12 mA input and adjust R3 until the meter's display reads "000." 4. Apply a precision 20 mA input and adjust R7 until the meter's display reads "1000." SW1 Off On Off On 5. Apply a precision 4 mA input and the display should read "-1000." Repeat steps 3 and 4 to make sure the two adjustments did not affect one another. Table 2 DMR20-4/20B (Bipolar Model) DIP-Switch Settings 4 mA 12 mA 20 mA SW3 SW2 Off Off On On Decimal Point DP3 DP2 DP1 None SW4 SW5 SW6 1 -600 to -1000 000 600 to 1000 Off Off Off Off 2 -400 to -600 000 400 to 600 On Off Off Off 3 -250 to -400 000 250 to 400 Off On Off Off 4 -150 to -250 000 150 to 250 Off Off On Off 5 -100 to -150 000 100 to 150 On Off On On 6 -70 to -100 000 70 to 100 Off On On On www.murata-ps.com/support MPM_DMR20-4/20.A01 Page 3 of 5 DMR20-4/20 Series Subminiature 4-20 mA Loop-Powered 31/2 Digit LED Process Monitors CONNECTION DIAGRAM Figure 2 Typical DMR20-4/20 Connection Diagram INSTALLATION DIAGRAM Figure 3 Panel Installation www.murata-ps.com/support MPM_DMR20-4/20.A01 Page 4 of 5 DMR20-4/20 Series Subminiature 4-20 mA Loop-Powered 31/2 Digit LED Process Monitors MECHANICAL SPECIFICATIONS AND RECOMMENDED PANEL CUTOUT http://www.murata-ps.com/en/3d/meters.html Available Panel Knockout Tools DMR20-1-KP DMR20-2-KP DMR20-3-KP 1.22" [30.9 mm] punch (no keying notch) 1.21" [30.7 mm] punch with 4 keying notches Keyway Punch tool Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Recommended Terminations at TB1 WIRE SIZE: 18 to 26 AWG (Solid or stranded) STRIPPING LENGTH: 0.20" [5.1 mm] Nominal This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2015 Murata Power Solutions, Inc. www.murata-ps.com/support MPM_DMR20-4/20.A01 Page 5 of 5