Hi-Rel AC/DC PFC MODULE HGMM-350 : 350W POWER Hi-Rel Grade 115 VAC Active Power Factor Corrected Variable Frequency 360-800Hz or 47-440Hz Non Isolated Output Metallic Case * AC/DC Non Isolated Power Factor Corrected Module * 115 VAC single phase * Permanent input range : 95 - 140 VAC * Transient input range : 71 - 180 VAC * Variable frequency : 360-800Hz or 47-440Hz * MIL-STD-704, MIL-STD-1399, ABD100 * Low input current harmonic distorsion < 10% * Output Power : 350W * Active inrush current limitation * Inhibition function * Leaded process 1- General The GAIA Converter HGMM-350 designates a family of non isolated AC/DC power factor corrected modules. The HGMM-350 family is designed to be compatible with the latest airborne single phase input bus 115VAC/400Hz fixed and variable frequency and shipborne single phase input bus 115VAC/60Hz. The modules accept an AC input voltage ranging from 95Vac to 140Vac and include active power factor that enables a very low level of current harmonic distorsion. The HGMM-350 is compliant with numerous avionics/military standards requirements among them with : * the latest Airbus standards ABD100 : - permanent input range : 108-122Vac - transient : 71Vac/15ms - 180Vac/100ms - variable frequency : 360 - 800 Hz - power factor : > 0,95 * the international standard DO-160D : - permanent input range : 100-122Vac - transient : up to 180Vac/100ms * the US military standard MIL-STD-704E : - permanent input range : 108-118Vac - transient : 80Vac/10ms - 180Vac/100ms * the US military standard MIL-STD-1399 The HGMM-350 modules include a soft start an active inrush current limitation, a permanent short circuit protection and an inhibit function. The soft-start/active current limitation eliminates inrush current during start-up, the short circuit protection protects the module against shortcircuits of any duration by a shut down and restores to normal when the overload is removed. The HGMM-350 output voltage is set to 375Vdc compatible with GAIA Converter high input voltage series of DC/DC converter and operates with a hold-up capacitance to allows transparency time and ripple reduction. The design has been carried out with surface mount components and is manufactured in a fully automated process to guarranty high quality. Every module is tested with a Gaia Converter automated test equipment. The modules are potted with a bi-component thermal conductive compound and packaged in a metalic case to ensure the module's integrity under high environmental conditions. 2- Product Selection Single output model : HGMS - 350 - input output / option suffix Input Voltage Range W : 95-140 VAC / 400 Hz X : 95-140 VAC / 60 Hz Options : /T : option for -55C start up operating temperature /S : option for screening and serialization Output T : 375 VDC Suffix : -L : leaded process REDEFINING THE SOURCE OF POWER (c) Gaia Converter FC06-051.12/13 Revision F For locations, phone, fax, E-Mail see back cover 4 HGMM-350 Series Hi-Rel Grade 3- Electrical Specifications Data are valid at +25C, unless otherwise specified. Parameter Conditions Limit or typical Units Nominal HGMS-350-W-T HGMS-350-X-T VAC 115 115 Min. - Max. VAC 95-140 95-140 Minimum Maximum. Nominal Min. Max. Transient compliant with ABD100 At full load At half load At quarter load from 25% to full load from 360Hz to 800Hz VAC/ms VAC/ms Hz Hz 71/15 180/100 400 360-800 71/15 180/100 60 47-440 Hz/s 320/0,3 / / 0,99 0,98 0,90 0,99 0,98 0,90 % < 10 < 10 50% to full load / see page 3 see page 3 Maximum Maximum Maximum peak ms ms A 30 200 110 400 10 Maximum mArms 250 50 Nominal VDC 375 375 Maximum VDC 450 450 Maximum % +/-3 +/-3 Maximum W 350 350 Maximum Vpp see curve page 12 see curve page 12 Maximum % +/-1 +/-1 Typical % 93 93 Minimum Maximum F F 68 560 270 1 000 Input Full temperature range between phase and neutral Permanent input voltage Full temperature range range (Ui) between phase and neutral Full temperature range Transient input voltage between phase and neutral Frequency range Full temperature range permanent (Fi) Ui min. to max. Frequency range Full temperature range transient Ui min. to max. Nominal input voltage Power Factor (PF) Total Harmonic Distorsion (THD) Individual current harmonic distorsion Start up time Start-up current Current in inhibit mode Ui nominal Fi nominal Ui min. to max. Ui min. to max. from Fi min. to max. Ui min. to max., Fi nominal with minimum capacitance Co with maximum capacitance Co Ui nominal, Fi nominal Ui nominal, Fi nominal Inhibit 4 Output Full temperature range Ui min. to max., full load Input voltage transient Output voltage transient Load fast change Ambient temperature : +25C Set point accuracy Ui nominal, 75% load Full temperature range Output power Ui min. to max. Ui nominal, Fi nominal Ripple output voltage Full load BW=20MHz Full temperature range Output regulation Ui min. to max., Fi nominal (Line + load + thermal) No load to full load Ui nominal, Fi nominal Efficiency Full load Admissible capacitive Full temperature range load (Co) Ui min. to max. Output voltage (c) Gaia Converter FC05-051.12/13 Revision F 2 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 3- Electrical Characteristics (continued) 3-1 Power Factor (PF) Characteristics The Power Factor (PF) is the ratio of the real power to the apparent power. The apparent power is the product of the rms volts measured with one meter and the rms amps measured with another meter (value in VA). The real power is the time average of the instant product of voltage and current (value in Watts). The real power cannot be measured directly with 2 meters as it has to integrate the phase shift between voltage and current. This phase shift between voltage and current reduces the effective power delivered. The Power Factor (PF) is a measure of the effectiveness with which an AC load can extract the usable power from an AC source. Power Factor (PF) versus Load at 115Vac for HGMS-350-X-T 1 0,9 0,9 0,8 0,8 0,7 0,7 Power Factor Power Factor Power Factor (PF) versus Load at 115Vac for HGMS-350-W-T 1 0,6 0,5 0,4 0,6 0,5 0,4 0,3 0,3 F=60Hz F=400Hz F=400Hz 0,2 0,2 F=800Hz 0,1 0,1 0 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 25 50 75 100 125 150 175 200 225 250 275 300 325 350 Load Load 3-2 Total Harmonic Distorsion Factor (THD) Characteristics The following curves represent the Total Harmonic Distorsion Factor (THD) for the HGMS-350-W-T at frequency of 400Hz & 800Hz and for the HGMS-350-X-T at frequency of 60Hz & 400Hz. Total Harmonic Distorsion (THD) at 115Vac for HGMS-350-W-T Total Harmonic Distorsion (THD) at 115Vac for HGMS-350-X-T 32,5% 30,0% 27,5% 25,0% 22,5% 20,0% 17,5% 15,0% 12,5% 10,0% 7,5% 5,0% 2,5% 0,0% 60,00% 55,00% 50,00% 45,00% 40,00% 35,00% 30,00% 25,00% 20,00% 15,00% 10,00% 5,00% 0,00% THD THD The Total Harmonic Distorsion (THD) is the ratio between the total energy contained in all row harmonic (except fundamental harmonic) by the fundamental harmonic wave. F=400Hz F=800Hz 0 50 100 150 200 250 300 350 Load 4 F=60Hz F=400Hz 0 50 100 150 200 250 300 350 Load 3-3 Individual Current Harmonic Distorsion (ICHD) Characteristics The Individual Current Harmonic Distorsion (ICHD) requirement is a very specific requirement defining for each harmonic row, the maximum admissible current in all functionning conditions. This requirement induced the Total Harmonic Distorsion Factor (THD) defined above. These requirements are mainly defined by the aircraft manufacturers in proprietary standards. (c) Gaia Converter FC05-051.12/13 Revision F GAIA Converter HGMM-350 complies with individual current harmonic distorsion requirements of : * AIRBUS ABD100 standard section 1.8 and its specific limits on odd non triplen and odd triplen harmonics even 2 & 4 and other even harmonics. * BOEING D6-44588 and its specific limits on odd non triplen and odd triplen harmonics even harmonics. * Various other standards : AIRBUS AMD24, MIL-STD-1399 3 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 3- Electrical Characteristics (continued) 3-4 Anharmonic Input Current The anharmonic input currents of the HGMS-350-W-T and HGMS-350-X-T are given hereafter at various frequencies at 350W power. Anharmonic Input Current at 400Hz for HGMS-350-W-T Anharmonic Input Current at 800Hz for HGMS-350-W-T Anharmonic Input Current at 60Hz for HGMS-350-X-T Anharmonic Input Current at 400Hz for HGMS-350-X-T 4 3-5 Efficiency The efficiency curves of the HGMS-350-W-T and HGMS-350-X-T are given hereafter : Efficiency versus Load at 115Vac for HGMS-350-W-T Efficiency versus Load at 115Vac for HGMS-350-X-T 94,00% 95,00% 93,00% 94,00% 93,00% Efficiency Efficiency 92,00% 91,00% 90,00% 89,00% F=400Hz F=800Hz 88,00% 92,00% 91,00% 90,00% 89,00% F=60Hz F=400Hz 88,00% 87,00% 87,00% 75 100 125 150 175 200 225 250 275 300 325 350 75 100 125 150 175 200 225 250 275 300 325 350 Power (W) (c) Gaia Converter FC05-051.12/13 Revision F Power (W) 4 For locations, phone, fax, E-Mail see back cover Hi-Rel Grade HGMM-350 Series 4- Switching Frequency Parameter Conditions Limit or typical Specifications Switching frequency Full temperature range Ui min. to max. No load to full load Nominal, fixed 250 KHz Conditions Limit or typical Specifications Input to output Minimum No isolation Pin to case Minimum 2 200 VDC / 1 min Pin to case Under 500 VDC Minimum 100 MOhm 5- Isolation Parameter Electric strength test voltage Isolation resistance 6- Protection Functions Characteristics Protection Device Recovery Limit or typical Specifications Output short circuit protection (SCP) Hiccup circuitry with auto-recovery Automatic recovery Permanent See section 11 Automatic recovery Typical 500W Automatic recovery Maximum 115C Output over power protection (OPP) Over temperature prootection (OTP) Thermal device with hysteresis cycle 4 7- Reliability Data Characteristics Mean Time Between Failure (MTBF) According to MIL-HDBK-217F Mean Time Between Failure (MTBF) According to IEC-62380-TR (c) Gaia Converter FC05-051.12/13 Revision F Conditions Temperature Specifications Ground fixed (Gf) Case at 40C Case at 85C 610 000 Hrs 170 000 Hrs Airborne, Inhabited, Cargo (AIC) Case at 40C Case at 85C 320 000 Hrs 110 000 Hrs Civilian avionics, calculators Ambient at 55C 100% time on 470 000 Hrs 5 For locations, phone, fax, E-Mail see back cover Hi-Rel Grade HGMM-350 Series 8- Electromagnetic Interference Electromagnetic interference requirements according to DO-160D or MIL-STD-461D/E can be easily achieved as indicated in the following table with the use of an additionnal external filter as described hereafter. Standards DO-160D MIL-STD-461E Compliance Conducted emission (CE) : Low frequency High frequency Section 21 CE 101 CE 102 compliant module stand alone compliant with additionnal filter Conducted susceptibility (CS) : Low frequency High frequency Section 20 CS 101 CS114 compliant with additionnal filter compliant with additionnal filter Radiated emission (RE) : Magnetic fireld Electrical field Section 21 RE 101 RE 102 compliant module stand alone compliant module stand alone Radiated susceptibility (RS) : Magnetic field Electrical field Section 20 RS 101 RS 013 compliant module stand alone compliant module stand alone 1 3 LMC1 C6 LMC2 Phase Vo On/Off C2 Ref C1 C4 HGMS-350 C5 C3 5 4 PFCsh 6 Drive 2 4 7 Go 8 Neutral C7 Gnd Recommended list of components : LMC1, LMC2 ......... : Common mode choke 2.5mH (Ferroxcube tore TN23/14/7-3E25 with 2x26 turns/wire diameter 0.56mm, or Wurth Elektronik : 744834622) C2, C3, C6, C7 ....... : Ceramic chip capacitors 2.2 nF/2Kv 1210 (example AVX : 1210GC222MAT) C1, C4 ................ : Film chip capacitor 2 x 150 nF/250V (example AVX : CB177K0154K) C5 ....................... : Ceramic chip capacitor 100 nF/500V (example Syfer : 1812J50000104MX) Fig : D0-160D Conducted Noise Emission (c) Gaia Converter FC05-051.12/13 Revision F 6 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 9- Thermal Characteristics Characteristics Conditions Limit or typical Performances Operating ambient temperature range Ambient temperature Minimum Maximum - 40C see below Operating case temperature range Case temperature Minimum Maximum - 40C see curves herafter Storage temperature range Non functionning Minimum Maximum - 55C + 125C Thermal resistance Rth case to ambiant in free air natural converction Typical 8C/W The following discussion will help designer to determine the thermal characteristics and the operating temperature. To calculate the maximum admissible ambient temperature the following method can be used. Heat can be removed from the baseplate via three basic mechanisms : Knowing the power used Pout and the efficiency : * determine the power dissipated by the module Pdiss that should be evacuated : - 1) (A) Pdiss = Pout(1/ * Radiation transfert : radiation is counting for less than 5% of total heat transfert in majority of case, for this reason the presence of radient cooling is used as a safety margin and is not considered. * Conduction transfert : in most of the applications, heat will be conducted from the baseplate into an attached heatsink or heat conducting member; heat is conducted thru the interface. * Convection transfert : convecting heat t r a n s f e r into air refers to still air or forced air cooling. In majority of the applications, we will consider that heat will be removed from the baseplate either with : * heatsink, * forced air cooling, * both heatsink and forced air cooling. * then determine the thermal dissipation : Tdiss = Rth(b-a) x Pdiss (B) where Rth(b-a) is the thermal resistance from the baseplate to ambient. This thermal Rth(b-a) resistance is the summ of : * the thermal resistance of baseplate to heatsink (Rth(b-h)). The interface between baseplate and heatsink can be nothing or a conducting member, a thermal compound, a thermal pad.... The value of Rth(b-h) can range from 0.4C/W for no interface down to 0.1C/W for a thermal conductive member interface. * the thermal resistance of heatsink to ambient air (Rth(h-a)), which is depending of air flow and given by heatsink supplier. 4 The table hereafter gives some example of thermal resistance for different heat transfert configurations. Heat transfert Thermal resistance heatsink to air Rth(h-a) No Heatsink baseplate only : Free air cooling only Forced air cooling 200 LFM Forced air cooling 400 LFM Forced air cooling 1000 LFM 8C/W Thermal resistance baseplate to heatsink Rth(b-h) No need of thermal pad Global resistance 8C/W Heatsink Thermalloy 6516B : 4,4C/W Bergquist Silpad* : 0,14C/W 4,54C/W Heatsink Fischer Elektronik SK DC 5159SA : 3,8C/W Bergquist Silpad* : 0,14C/W 3,94C/W No Heatsink baseplate only : 4,5C/W No need of thermal pad Heatsink Thermalloy 6516B : 3C/W Bergquist Silpad* : 0,14C/W 3,14C/W Heatsink Fischer Elektronik SK DC 5159SA : 2,5C/W Bergquist Silpad* : 0,14C/W 2,64C/W No Heatsink baseplate only : 3,2C/W No need of thermal pad Heatsink Thermalloy 6516B : 1,75C/W Bergquist Silpad* : 0,14C/W 1,89C/W Heatsink Fischer Elektronik SK DC 5159SA : 1,7C/W Bergquist Silpad* : 0,14C/W 1,84C/W No Heatsink baseplate only : 1,7C/W No need of thermal pad Heatsink Fischer Elektronik SK DC 5159SA : 0,9C/W Bergquist Silpad* : 4,5C/W 3,2C/W 1,7C/W 0,14C/W 1,04C/W Fischer Elektronic and Thermalloy are heasink manufacturers. Silpad (c) is a registered trademark of Bergquist. Note* : Silpad performance are for Silpad 400 with pressure conditions of 50 Psi. Surface of HGMM-350 series is 5,5 inch2. (c) Gaia Converter FC05-051.12/13 Revision F 7 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 9- Thermal Characteristics (continued) conduct to determine the maximum ambient temperature admissible as a function of the maximum baseplate temperature of the module. The two formulas (A) and (B) described in previous page : * Pdiss = Pout(1/ - 1) (A) * Tdiss = Rth(b-a) x Pdiss (B) Knowing the maximum baseplate temparature Tmaxbaseplate the maximum ambient temperature is given by the following formula : Ta = Tmaxbaseplate - Tdiss (C) Maximum Baseplate Temperature versus Output Power 120 80 Baseplate temperature (C) Maximum Baseplate Temperature (C) 100 60 4 40 20 0 0 50 100 150 200 250 300 350 400 Output power (W) (c) Gaia Converter FC05-051.12/13 Revision F 8 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 9- Thermal Characteristics (continued) : Heatsink Mounting To mount properly the module to heatsink, some important recommendations need to be taken into account in order to avoid overstressing conditions that might lead to premature failures. The module case is built with a copper IMS (isolated metalic substrate ) crimped on an aluminum frame that provides case rigidity. The IMS surface is the module base plate that need to be reported to heat sink to achieve proper cooling. If for some reasons like poor module report, the IMS base plate is subject to mechanical overstress, module's electrical characteristics may be definitely affected. A typical example of damageable report is the use of thick thermal interface with usual screwing torque applied on mounting screws. This combination causes a high pressure on baseplate center due to thermal interface material compression. The final consequence is a slight IMS bending that can conduct for the module to fail high voltage isolation leading to heavy electrical damage on internal circuit. Base plate overstress Heatsink Too ThickThermal Pad PCB screw Poor report not recommended Example of banned thermal interface : Bergquist Gap Pad VO Ultra Soft The good practice is to respect the 4 following recommendations: - do not exceed recommended screwing torque of 0,7 N.m (6 lbs.in) Heatsink - prefer thin thermal pad with thickness lower than 0,34 mm (0.015"). GAIA Converter recommends to use thin thermal pads instead of thermal compound like grease. Thermal Pad - take care to reflow module leads only when all assembly operations are completed. PCB - do not report module on surfaces with poor screw flatness characteristics. GAIA Converter recommends not to overflow 0,1mm/m for the surface flatness. Example of recommended thermal interfaces: Bergquist Silpad 400 4 Gaia converter suggests to follow the procedure hereunder for the mechanical assembly procedure in order to avoid any stress on the pins of the converters. It is good practice to be sure to mount the converters first mechanically, then solder the units in place. 1. Choice of the thermal gap pad : its shape must be the same as the module. The dimensions of the gap pad can be a little larger than the module. 2. Screw the converter to the heatsink and/or to the board. The four screws have to be screwed in a "X" sequence. * Lightly finger-tighten all screws and run several X sequences before achieving final torque to get homogeneous tightening. * Torque screws from 0,35 N.m (3 lbs.in) to 0,7 N.m (6 lbs.in). 1 4 3 2 3. Screw the heatsink to the board. 4. Solder the pins of the converters on the board. This sequence avoids mechanical stresses on the converters that could lead to stress internal components or assemblies and cause their failures. (c) Gaia Converter FC05-051.12/13 Revision F 9 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 10- Environmental Qualifications The modules have been subjected to the following environmental qualifications. Characteristics Conditions Severity Test procedure Duration Temperature / status of unit Test D : 1 000 Hrs @ 105C case, unit operating @ 125C ambient, unit not operating MIL-STD-202G Method 108A Altitude Altitude level C Duration Climb up Stabilization Status of unit 40 000 ft@-55C 30 min. 1 000 ft/min to 70 000 ft@-55C, 30 min. unit operating MIL-STD-810E Method 500.3 Humidity cyclic Number of cycle Cycle duration Relative humidity variation Temperature variation Status of unit 10 Cycle I : 24 Hrs 60 % to 88 % 31C to 41C unit not operating MIL-STD-810E Method 507.3 Humidity steady Damp heat Temperature Duration Status of unit 93 % relative humidity 40C 56 days unit not operating MIL-STD-202G Method 103B Salt atmosphere Temperature Concentration NaCl Duration Status of unit 35C 5% 48 Hrs unit not operating MIL-STD-810E Method 509.3 Temperature cycling Number of cycles Temperature change Transfert time Steady state time Status of unit 200 -40C / +85C 40 min. 20 min. unit operating MIL-STD-202A Method 102A Temperature shock Number of shocks Temperature change Transfert time Steady state time Status of unit 100 -55C / +105C 10 sec. 20 min. unit not operating MIL-STD-202G Method 107G Climatic Qualifications Life at high temperature 4 Mechanical Qualifications Vibration (Sinusoidal) Number of cycles Frequency / amplitude Frequency / acceleration Duration Status of unit 10 cycles in each axis 10 to 60 Hz / 0,7 mm 60 to 2 000 Hz / 10 g 2h 30 min. per axis unit not operating MIL-STD-810D Method 514.3 Shock (Half sinus) Number of shocks Peak acceleration Duration Shock form Status of unit 3 shocks in each axis 100 g 6 ms 1/2 sinusoidal unit not operating MIL-STD-810D Method 516.3 Bump (Half sinus) Number of bumps Peak acceleration Duration Status of unit 2 000 Bumps in each axis 40 g 6 ms unit not operating MIL-STD-810D Method 516.3 (c) Gaia Converter FC05-051.12/13 Revision F 10 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 11- Description of Protections 11-1 Output Short Circuit Protection (SCP) The short circuit protection device protects the module against short circuits of any duration. It operates in hiccup mode by testing approximately every recovery time (typically 1.1s) if an overload is applied with a detection time lower than 70ms and restores the module to normal operation when the short circuit is removed. Vo (%) 100 detection time x time recovery time 11-2 Output Over Power Protection (OPP) The HGMM-350 incorporates a foldback power limit and protection circuit. When the output power reaches 1,5 time it's full-rated power, the output voltage falls along the foldback line as described in the figure herein. When the output voltage decreases below 40% of VOnom the module fall in a hiccup mode and activates the short circuit protection. The module restart automatically to normal operation when overcurrent is removed. recovery time Vo (%) 100 40 Pout P Hiccup Po nom 1.5 Po nom 4 11-3 Over Temperature Protection (OTP) A thermal protection device adjusted at 115C (+/-5%) internal temperature with 10C hysteresis cycle will inhibit the module as long as the overheat is present and restores to normal operation automatically when overheat is removed. The efficiency of the OTP function is warranty with the module mounted on a heatsink. On Off 10c 115c (c) Gaia Converter FC05-051.12/13 Revision F Baseplate Temperature 11 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 12- Description of Functions 12-1 On/Off Function The control pin 4 (On/Off) can be used for applications requiring On/Off operation. This may be done with an open collector transistor, a switch, a relay or an optocoupler. * The converter is disabled by pulling low the pin 4. * No connection or high impedance on pin 4 enables the converter. By releasing the On/Off function, the converter will restart within the start up time specifications given in table section 4. Parameter Unit Min. Typ. Max. On/Off module enable voltage Vdc 2,35 / 5,5 On/Off module disable voltage Vdc 0 / 2,35 On/Off module enable delay ms / / / On/Off module disable delay s / / 100 1 Vo Phase On/Off 3 4 Ref 5 HGMS-350 PFCsh 6 Drive 2 Notes, conditions Neutral On/Off 7 Go 8 See start-up time Vin, full load 12-2 Drive Function The HGMM-350 with it's 375Vdc output has to be used in conjunction with a hold-up capacitor and a companion isolated module MGDM-150-T series of GAIA Converter. The drive function is a signal that controls the start-up and the stop of the the companion module. At start-up of the HGMM-350, the drive function is in low impedance status preventing the companion module to start as long as the hold-up capacitor is not charged to reach 375Vdc. When the capacitor reaches 90% of it's charge, the drive signal is released allowing the companion module to start-up. If the HGMM-350 is powered-down in case of input bus failure for example, the hold-up capacitor will discharge to maintain the companion module in operation down to a voltage of 150Vdc then the drive signal will stop the companion module to operate with a low impedance signal. Parameter Drive Impedance 4 High Low 0 Unit Min. Max. Notes, conditions Enable threshold % of VOnom 89% 93% / Disable threshold % of VOnom 39% 44% / 42% Vonom 90% Vonom Vonom Vo 12-3 REF Function The signal REF is an auxiliary voltage of 7,5Vdc +/-2% referenced to Go. It can provide a maximum current of 1.5mA. It is recommended to add a 100nF decoupling capacitor when this signal is used. When the module is turned off or when there is an input power interruption, the signal Vref drops to 0Vdc. 12-4 PFCSH Function The HGMM-350 features a trim function Please consult factory for details. (c) Gaia Converter FC05-051.12/13 Revision F 12 For locations, phone, fax, E-Mail see back cover Hi-Rel Grade HGMM-350 Series 13- Application Notes 13-1 Connections A low ESR capacitor is recommended; as this ESR increases with temperature the following ratings should apply : - max ESR @ 20C : 1 Ohm - max ESR @ -40C : 5 Ohm The capacitor voltage rating has to be chosen according to the maximum permanent & transient output voltage specified. The charts hereby specify for a given capacitance value the resultant output ripple value for the HGMS-350-W-T and for the HGMS-350-X-T. Maximum capacitor value range is given in table section 3. This capacitor is also used to achieve hold-up function for transparency time. 8 Output Ripple (Vpp) Output ripple (Vptop) This capacitor has to be carrefully chosen to avoid damaging the HGMM-350. Output Ripple vs Output Capacitor for HGMS-350-W-T 7 F=400Hz 6 F=800Hz 5 4 3 2 1 0 0 100 200 300 400 500 600 Output capacitor (F) Output Ripple vs Output Capacitor for HGMS-350-X-T Output (Vpp) Output Ripple ripple (Vptop) The HGMM-350 has to be used in conjunction with an external hold-up capacitor accross the outputs to limit the output voltage ripple. 12 11 10 9 8 7 6 5 4 3 2 1 0 F=60Hz F=400Hz 200 300 400 500 600 700 800 900 1000 Output capacitor (F) 4 The HGMM-350 output voltage is a high and non isolated voltage of 375 Vdc. To achieve usual low voltages such as 5, 15 .... or 28 Vdc, the HGMS-350 module has to be connected with a GAIA Converter compatible companion module. Companion modules can be found among all the high input series i.e with 120V-480V input range down to low voltage as shown in the figure below. 1 Vo Phase On/Off 3 5 4 4 Ref 5 EMI input filter HGMS-350 PFCsh Drive 2 Neutral Go 6 375Vdc / 350W Intermediate Bus Vin S+ On/Off 3 Share 7 2 Sync 8 1 MGDM150 6 7 Trim 8 S- Gin Go 9 10 5 Vin Vo 6 4 S+ On/Off 3 Share 2 1 (c) Gaia Converter FC05-051.12/13 Revision F Vo MGDM150 7 Trim 8 Sync S- 9 Gin Go 10 13 For locations, phone, fax, E-Mail see back cover HGMM-350 Series Hi-Rel Grade 14- Dimensions Dimension are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 ") unless otherwise indicated. Weight : 110 grams (4.30 Ozs) max. Mouting Hole 0 3,1 (0,122) 10,16 (0.4) 5,08 5,08 5,08 10,16 7,62 (0.2) (0.2) (0.2) (0.4) (0.3) 5,08 (0.2) 0,5 (0.019) 9,589 (0.38) 4,826 (0.19) 9,894 (0.39) 57,912 (2.28) 48,26 (1.90) Use this side for heat sinking 5,6 min (0.22) .4 R2 50,8 (2.00) 60,95 (2.40) CH 2x2 ) ,1 (0 12,7 Max (0.5) 6,8 max (0.267) Pin dimensions : O 1 mm (0.04") 4 15- Materials Frame : Aluminium alodined coating. Baseplate : Copper with tin finishing. Pins : Plated with pure matte tin over nickel underplate. 16- Product Marking Side face : Company logo, location of manufacturing. : Module reference : HGMS-350-X-Y. Date code : year and week of manufacturing, suffix, /option. 17- Connections 2 3 Pin Single output 1 Phase 1 4 5 6 7 2 Neutral 3 Output (Vo) 4 On/Off 5 Ref 6 PFCSH 7 Drive 8 Common (Go) 8 Bottom view (c) Gaia Converter FC05-051.12/13 Revision F 14 For locations, phone, fax, E-Mail see back cover International Headquarters GAIA Converter - France ZI de la Morandiere 33185 LE HAILLAN - FRANCE Tel. : + (33)-5-57-92-12-80 Fax : + (33)-5-57-92-12-89 North American Headquarters GAIA Converter Canada, Inc 4038 Le Corbusier Blvd LAVAL, QUEBEC - CANADA H7L 5R2 Tel. : (514)-333-3169 Fax : (514)-333-4519 Represented by : Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use. These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice. Printed in France by GAIA Converter Gaia Converter FC05-051.12/13 Revision F. Graphisme : Philippe Clicq For more detailed specifications and applications information, contact :