INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R02
LCA100L
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @25ºC
Parameter Ratings Units
Blocking Voltage 350 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
AC/DC Confi guration, Continuous 1-I
L- - 120 mArms & mADC
DC Confi guration, Continuous 1-I
L- - 200 mADC
On-Resistance 2
AC/DC Confi guration IL=120mA RON
--25
DC Confi guration IL=200mA -- 8
Off-State Leakage Current VL=350V ILEAK -- 1 µA
Switching Speeds
Turn-On IF = 5mA, VL = 10V ton -- 5 ms
Turn-Off toff -- 5 ms
Output Capacitance 50V, f=1MHz COUT -35 - pF
Load Current Limiting - ICL 130 170 210 mA
Input Characteristics
Input Control Current to Activate IL = 120mA IF-- 5 mA
Input Control Current to Deactivate - IF0.4 0.7 - mA
Input Voltage Drop IF = 5mA VF0.9 1.2 1.4 V
Reverse Input Current VR = 5V IR- - 10 µA
Common Characteristics
Capacitance, Input to Output - CI/O -3 - pF
1 If both poles operate, then the load current must be derated so that the package power dissipation value is not exceeded.
2 Measurement taken within 1 second of on-time.
Electrical Characteristics @25ºC (Unless Otherwise Noted)